• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 1
  • Tagged with
  • 96
  • 96
  • 78
  • 69
  • 33
  • 30
  • 27
  • 27
  • 25
  • 21
  • 21
  • 20
  • 19
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação da responsividade a fluido por meio de índices dinâmicos em cães mecanicamente ventilados e submetidos a diferentes tipos de cirurgia / Evaluation of fluid responsiveness by dynamics indices in mechanically ventilated anesthetized dogs undergoing diferente types of surgery

Gonçalves, Lucas Alaião 14 December 2018 (has links)
A prova de carga com cristaloides é uma das intervenções mais comumente realizadas diante da hipotenção trans-anestésica, contudo, nem todo animal que apresenta hipotensão é responsivo a fluidoterapia. Por esta razão, na ultima década, vários índices que avaliam a responsividade a fluido foram desenvolvidos com o intuito de otimizar o emprego da fluidoterapia no paciente hemodinamicamente instável. . O objetivo desse trabalho foi avaliar três diferentes índices de responsividade, quais sejam: a variação da integral velocidade-tempo (ΔIVT), variação da velocidade de pico do fluxo aórtico (ΔVFAO) e variação da pressão de pulso (VPP) no que tange a sua capacidade diagnóstica. Para tanto, foram utilizados 40 cães submetidos a anestesia inalatória associada a anestesia epidural. Em caso de detecção de pressão arterial média < 65 mmHg, foi realizado uma prova de carga com cristalóde de 15 ml/kg durante 15 minutos. Volume sistólico (VS) obtido por meio da ecocardiografia transesofágica foi utilizado para definir a responsividade a fluido, sendo que os cães responsivos foram aqueles em que um aumentou no VS igual ou superior a 15% foi observado após o desafio com o cristalóide. Os dados foram avaliados pela análise da curva ROC para comparação dos testes diagnósticos, assim como a análise da curva cinzenta e também pela probabilidade pré e pós-teste. Trinta cães (75%) foram responsivos a fluidoterapia e 10 (25%) não eram responsivos. Tanto a ΔVFAO quanto a ΔIVT apresentaram boa capacidade discriminativa pela análise da Área sob a curva (0.89 e 0.93), assim como a VPP (0.88). Além disso, a análise da área cinzenta e da probabilidade pós-teste sugeriram uma melhor capacidade em diagnosticar os animais responsivos a fluido do que não-responsivos. Os valores de corte que distinguem responsivos a fluidoterapia de não-responsivos foram semelhantes aos observados na literatura. Sobe ventilação controlada e após a anestesia epidural, os índices ecocardiográficos de responsividade a fluido apresentaram boa capacidade discriminativa. / Intravenous fluid resuscitation is the first therapeutic choice used against arterial hypotension, however, not every animal with arterial hypotension is responsive to fluids. In the past decade, many indices of fluid responsiveness were introduced and plenty of studies covering many scenarios on the surgery context have been published. Therefore, the aim of this study was to evaluate the diagnostic accuracy of velocity-time integral variation (ΔTI), peak aortic velocity variation (ΔVpeak) and pulse pressure variation (PPV). Forty dogs were included in this study. Whenever a mean arterial pressure < 65 mmHg, a 15 ml/kg fluid challenge with crystalloids over 15 minutes was administered. Responders to fluids were defined by means of transesophageal echocardigraphy if an increase equal to or greater than 15% in stroke volume was observed after the fluid challenge. For the statistical evaluation, ROC curve analysis, gray zone approach, and pre-test, post-test probability were used to estimate the diagnostic capability of each index. Thirty (75%) dogs were responders and 10 (25%) were non-responders. Both velocity-time integral variation (ΔVTI) and aortic blood velocity variation (ΔVpeak) showed a good diagnostic capability according to the Area under curve analysis (0.89 e 0.93), as well as PPV (0.88). Moreover, the gray zone approach and the post-test probability suggests a greater ability to detect fluid responders. The optimum cutoff value to discriminate responders from non-responders for all dynamics indices were similar to that observed in the literature. After the epidural anesthesia and under mechanical ventilation, all dynamic índices showed good diagnostic ability in predicting fluid responsiveness.
12

Análise de comportamento de estaca barrete embutida em rocha. / Behavior analysis of a rock socket barrette pile.

Musarra, Marcello Duarte 01 September 2014 (has links)
Para proporcionar menores prazos e custos, o projeto de ampliação da sede da Petrobras, na cidade de Salvador, estado da Bahia, contemplou estacas barretes de grandes dimensões para grandes capacidades de carga. Porém, para atingir as cargas escolhidas, foi necessário embutir as estacas no topo rochoso. Portanto, foram projetadas estacas barretes embutidas em rocha, escavadas com hidrofresa. Esta pesquisa apresenta o estudo de duas provas de carga estáticas executadas em uma mesma estaca barrete teste embutida em rocha, a fim de proporcionar um melhor entendimento de seu comportamento, assim como os principais fatores que influenciam resistência e deformabilidade. Em março de 2012, foram realizadas duas provas de carga estáticas na mesma estaca barrete teste embutida em rocha. Os ensaios foram executados a partir das metodologias normativas NBR 12131 (2006) e NBR 6122 (2010), com carregamentos lento e rápido, respectivamente e subsequentemente. No primeiro ensaio (lento), aplicou-se a carga máxima de 12 MN, enquanto que no segundo (rápido), aplicou-se a carga máxima de 14 MN. Os dados obtidos nos ensaios, de acordo com a bibliografia utilizada, são pioneiros no Brasil, por se tratar da primeira estaca barrete embutida em rocha com utilização de hidrofresa, submetida à prova de carga de desempenho. A estaca foi instrumentada em profundidade, o que propiciou a avaliação da distribuição de carga nas camadas atravessadas. Foram realizadas comparações entre resultados obtidos da instrumentação e do topo, por meio do repique elástico. Além da avaliação e interpretação dos dados obtidos nos ensaios de provas de carga estáticas, esta pesquisa apresenta previsões de comportamento, com diferentes conceitos, para estacas embutidas em rocha, sem reação de ponta, com intuito de comparar seus resultados com os obtidos nos ensaios. Em conjunto com as previsões, foram apresentados métodos para estimativa de adesão lateral na interface da estaca com o maciço rochoso. / To use high loads on foundations of the Petobras Headquarters, the designers chose the barrette pile with great dimensions and a few units compared with others types, to shorten the deadline and optimize costs. However, to reach these assumptions, it was necessary make the piles deeper than the soil strata, and, therefore, made a rock socket design. This research presents two static load tests study and analysis in the same barrette test pile, to forecast behavior and find resistance and strain influences. In March, 2012, two static load tests were made in the same barrette test pile located in Salvador Bahia, in Petrobras headquarters. The first essay was made according to a slow maintained test with 12 MN maximum compressive loads. The second essay was made immediately after, according to a quick load test and 14 MN maximum compressive loads. The data obtained from both tests, far as is known, were the first results on rock socket barrette pile in Brazil, using hydromill for the excavations in rock. The pile had depth instrumentation with expansible strain gages and an expanded polystyrene block below the cage, to make the tip useless. Beyond the data assessment and interpretation from static load tests, this research presents forecasting methods to only shear resistance rock socket piles, with the aim of comparison. Lastly but not least, side resistance empirical methods between pile and rock interface were presented.
13

Cravação de tubulões a céu aberto para melhoria da capacidade de carga em solos colapsíveis / Driving of belled piles to improve bearing capacity on collapsible soils

Benvenutti, Márcio 08 November 2001 (has links)
Os tubulões a céu aberto são amplamente utilizados como elementos estruturais de fundação de edifícios residenciais nas cidades pequenas e médias do Brasil. Relatam-se as etapas de um projeto de fundações por tubulões desenvolvido em uma área previamente ocupada por construções residenciais antigas. Após cuidadosa demolição e limpeza, deparou-se com o desafio de executar as fundações sem o perigo de danificar as construções adjacentes (tubulões à céu aberto de divisa nos dois lados e no fundo). No projeto, utilizaram-se procedimentos usuais e alguns específicos que refletem a prática corrente nos últimos 10 anos, na região de Campinas, com resultados extremamente satisfatórios. Nos solos porosos e colapsíveis, presentes em várias regiões brasileiras, as fundações não raramente têm apresentado comportamento inadequado, quando o solo é inundado. Com a significativa elevação do seu teor de umidade, esses solos exibem o recalque de colapso, caracterizando-se como colapsíveis. Como já se tem a comprovação da eficiência da compactação do solo para viabilizar o emprego de fundações rasas, por sapatas, em solos colapsíveis (CINTRA, 1998), resolveu-se estudar os possíveis benefícios da criação de tubulões a céu aberto. No campo experimental de Fundações da USP/São Carlos, foram executadas dois tubulões a céu aberto com fuste de diâmetro de 0,50 m e base apoiada à cota - 6,00 m, com diâmetro de 1,50 m e altura de 0,90 m. O primeiro tubulão a céu aberto foi ensaiado na condição não-inundada do solo, na cota inicial de apoio da base e sucessivamente, com a cravação de 0,15 m, 0,30 m e 0,45 m, o que corresponde a 10%, 20% e 30% do diâmetro da base, respectivamente. Observou-se que a cravação majorou a capacidade de carga em 42%, 85% e 12%, respectivamente. O segundo tubulão a céu aberto foi ensaiado com o solo pré-inundado, para quantificar o efeito da colapsibilidade do terreno na redução da capacidade de carga. ) Constatou-se uma redução de 51% a 53% nos valores de capacidade de carga anteriormente obtidos. Mas a carga de colapso, ou capacidade de carga na condição inundada, também teve uma majoração importante, aumentando em 45%, 90% e 135% com a cravação de 10%, 20% e 30% do diâmetro da base, respectivamente. Conclui-se que a cravação de tubulões a céu aberto, inicialmente executados com escavação e concretagem in situ, pode ser uma solução interessante em solos colapsíveis. / The belled piles are largely used as fundation for structural elements of residential buildings in small and medium cities in Brazil. The steps of a foundation design is developed in an area previously occupied by old residential buildings. After a careful demolition and clean up process, the challenger is to build the foundations without the danger of harming the adjacent buildings (Division of belled piles on both side and on the bottom). On the design, some specific and some standard procedures are used, which reflect the current practice over the last 10 years, in the Campinas region, with extremely satisfactory results . In porous and collapsible soil, that can be found in many Brazilian regions, these piles usually have presented an inadequate behavior, when the soil is soaked. With a significant elevation on its moisture content, these soils present the collapse settlement, being characterized as collapsible. Since there is already the confirmation of the compacting process efficacy in making the employment of shallow foundations on collapsible soils feasible (CINTRA, 1998), it was decided to study the possible benefits of driving the belled piles on the improvement of the bearing capacity. At the Experimental Foundation Field of USP/São Carlos, two piles were tested. Both piles were 6,00 m long and had a shaft diameter of 0.50 m. The enlarged bases had a diameter of 1.50 m and a height of 0.90 m. The first pile was tested under the non-soaked condition of the soil, on the initial quota of base support, and then with the 0.15 m, 0.30 m and 0.45 driving, which corresponds to 10%, 20%, and 30% of the base diameter, respectively. It was observed that the driving improved the bearing capacity in 42%, 85%, and 127%, respectively. The second pile was tested on a soaked soil, to quantity the collapsibility effect on the reduction of the bearing capacity. A reduction of 51% to 53% on the values of the bearing capacity previously obtained was observed, but the collapse load, also presented an important improvement, increasing 45%, 90%, and 135% with the driving of 10%, 20%, and 30% of the base diameter, respectively. We can conclude that the driving of belled piles, inittially executed with digging and concreting in situ, may be an interesting solution on collapsible soils.
14

Análise de provas de carga estática em estacas pré-moldadas cravadas na cidade de Curitiba e região metropolitana / Analysis of static loading tests in concrete drive pile carried out in Curitiba city and metropolitan area

Vianna, Ana Paula Fontana 29 June 2000 (has links)
Nesta dissertação são analisadas 34 provas de carga estática realizadas em estacas pré-moldadas de concreto, cravadas em diferentes locais da cidade de Curitiba e região metropolitana, sendo a maioria delas na Formação Guabirotuba. Três métodos de previsão da capacidade foram analisados: Aoki – Velloso (1975), Décourt – Quaresma (1978) e Amaral (1982, 1999). Para cada método foram propostos fatores de correção global e/ou parcial que tornam o valor da capacidade de carga mais próximo do valor da carga última obtida pelo critério de Van der Veen (1953). Com base em quatro provas de carga conduzidas até a ruptura, estudou-se a aplicabilidade do método de Van der Veen (1953) e determinou-se um critério para avaliar a extrapolação da curva carga x recalque em ensaios encerrados sem atingir a ruptura. Finalmente fez-se uma análise dos recalques comparando-se os valores medidos com os calculados, para três níveis de carregamento, além da comparação das curvas carga x recalque ajustadas com as experimentais. / This thesis presents the analysis of 34 static loading tests in concrete drive pile, located at different places of the Curitiba city and metropolitan area, in Guabirotuba Formation. Three methods of the bearing capacity prediction were assessed: Aoki – Velloso (1975), Décourt – Quaresma (1978) and Amaral (1982, 1999). For each method is proposed global correction factors and/or partial that turned the bearing capacity value close to the ultimate load obtained for the Van der Veen criteria (1953). Based on four static loading test carried out to failure, the applicability of the Van der Veen criteria was assessed and was determined a rule to evaluate the extrapolation of the load - settlement curve in tests stopped before of the failure. Finally, it was made an analysis of the settlements, where it was compared the observed values and the predicted values, for three loading level, and also a comparison between the experimental load-settlement curve and the predicted load-settlement curve.
15

Comportamento de tubulões escavados a céu aberto, submetidos a carregamentos dinâmicos, em solo colapsível / not available

Campelo, Nilton de Souza 13 April 2000 (has links)
Provas de carga dinâmicas em sete tubulões, de oito metros de comprimento e 0,60 m de diâmetro de fuste, sendo quatro com 1,5 m de base alargada, são apresentadas. Resistências mobilizadas determinadas pelo PDA e pela utilização de métodos que empregam medidas de repique elástico, em particular, os métodos de CHELLIS-VELLOSO e UTO et al. (1985) são comparadas. Várias seqüências de carregamento foram efetuadas, de modo a se ter uma ideia da influência de carregamentos sucessivos no comportamento dos tubulões. Constatou-se que o método de CHELLIS-VELLOSO apresentou resultados sofríveis em relação às resistências encontradas pelas análises CAPWAP, mas que melhoram à medida que sucessivos carregamentos são impostos aos tubulões, por causa do gradual comportamento de tubulões escavados em tubulões \"cravados\", pelo acúmulo de tensões residuais de cravação. Este fato pode ser corroborado pela aplicação do Princípio de Hamilton aos tubulões, fazendo crer que a realização de um ensaio de carregamento dinâmico em elementos de fundação moldados in loco necessita de uma suficiente penetração líquida deste elemento no terreno - da ordem do seu diâmetro, se este for de seção uniforme -, ou seja, sua transformação em um elemento de comportamento \"cravado\". Em alguns tubulões, provas de carga dinâmicas foram efetuadas com o solo em estado natural e inundado, a fim de se determinar a influência da colapsibilidade na resistência mobilizada, conforme o nível de energia aplicado. Verificou-se que em um tubulão submetido a uma inundação prévia do terreno por 48 h, as resistências mobilizadas foram inferiores às encontradas nos demais, para um mesmo nível de energia, muito provavelmente pela ação deletéria da água na colapsibilidade do solo em tela. / Dynamic Loading Tests (DLT) on seven caissons 8 m length and 0,60 m shaft diameter are presented, being four caissons with 1,5 m enlarged base diameter. Mobilized resistances determined both through PDA and rebound measurement methods as CHELLIS-VELLOSO and UTO et al. (1985) are compared. SeveraI successive loadings were performed in order to obtain assessment of the influence of the loading sequence in the caisson behavior. It was observed what CHELLIS-VELLOSO method showed very poor agreement with the obtained resistances through the CAPWAP analysis. Nevertheless, it was noted what the more the caissons are submitted to successive loadings, the closer are the results between CAPWAP analysis and CHELLIS-VELLOSO method, because the cast-in-place caisson is gradually switched to a driving caisson due to driving residual stress accumulations. To allow this to happen, it is necessary to have a net set value close to the shaft diameter in caisson without enlarged base. These facts were confirmed through the application Hamilton\'s Principle to tested caissons. In some caissons DLT were performed with natural and soaked soil conditions in order to know the collapsible influence in the mobilized resistances. lt was verified what 48 hours previous soaked soil resulted in lowest resistances than observed in the other caissons to the same energy level. This fact may justify the harmful action of the water in the reduction of resistance in collapsible soils.
16

Previsões do comportamento carga-recalque de estaca escavada com polímero / Prediction of Load-Displacement Behavior of Bored Pile with Polymer

Alves, Débora Fonseca January 2016 (has links)
O evento de previsões do comportamento carga-recalque de uma estaca executada em solo predominantemente arenoso foi apresentado no 8° Seminário de Engenharia de Fundações Especiais e Geotecnia (SEFE8). As previsões utilizaram sondagens CPT, DMT e SPT realizadas no campo experimental de Araquari, em Santa Catarina. A estaca utilizada para o evento foi do tipo escavada com polímero, diâmetro de 100cm e comprimento de 24m. Foram recebidos pelo comitê organizador 73 previsões provenientes de 20 países, com estimativas do comportamento carga-recalque da estaca, da capacidade de carga total, lateral e de ponta e a distribuição de carga ao longo do fuste até a ruptura, definida pelo recalque de 100 mm (w/D = 10%), com um resumo dos métodos e considerações. Os dados das previsões foram comparados aos resultados obtidos em campo pela prova de carga estática da estaca instrumentada. As previsões foram majoritariamente conservadoras e o ensaio mais utilizado para determinação dos parâmetros do solo foi o CPT, tanto no meio acadêmico quanto no prático Diversos métodos foram utilizados, porém mesmo previsões que utilizaram o mesmo método apresentaram variabilidades nos resultados. Baixos valores de desvio na capacidade de carga total não significaram pequenos desvios de lateral e de ponta, mas uma combinação de desvios positivos e negativos desses. A maioria das estimativas subestimou a capacidade lateral e superestimou a de ponta. O método de Verbrugge (1981) foi utilizado em duas das cinco previsões com menores desvios de capacidade total. As curvas carga-recalque e carga-profundidade foram avaliadas quanto aos desvios médios absolutos e formatos, dados pela variância. As curvas carga-recalque com médias de até 10% utilizaram Elementos Finitos e o software UniPile, e o menor valor de variância utilizou Verbrugge (1981). As curvas carga-profundidade com médias de até 10% utilizaram Verbrugge (1981), Randolph e Wroth (1978) e Gwizdala e Steczniewski (2003), e o menor valor de variância utilizou o software UniPile. / The prediction event of load-settlement behavior of a pile built in predominantly sandy soil was presented at the 8th Foundation Engineering Seminar and Special Geotechnical (SEFE8). The predictions used tests of CPT, DMT and SPT accomplished in Araquari experimental field, in Santa Catarina. A bored pile with polymer, diameter of 100cm and length of 24m was the subject of the event. The organizing committee received 73 predictions from 20 countries, with estimates of load-settlement behavior of the pile, the total, shaft and base load capacity and the load distribution along the shaft until failure, defined by settlement of 100 mm (W/D = 10%), with a brief description of methods and considerations. Data from the predictions were compared to the results obtained in the field by static load test of the instrumented pile. The predictions were mostly conservative and the test most used for soil parameters prediction was the CPT, both in academia as in practice. Several methods were used, but even predictions that used the same method showed variability in the results Low error values in the total load capacity not meant small shaft and base errors, but a combination of positive and negative errors of these. Most estimates underestimated the shaft capacity and overestimated the base. The Verbrugge (1981) method was used in two of five predictions with lower errors of total capacity. The curves were analyzed for absolute average deviation and formats, evaluated by the variance. The load-settlement distribution with average up to 10% used Finite Element and UniPile software, and the lowest value of variance used Verbrugge (1981). The load-depth distribution with average up to 10% used Verbrugge (1981), Randolph and Wroth (1978) and Gwizdala and Steczniewski (2003), and the lowest value of variance used the UniPile software.
17

Utilização de penetrômetro manual em solo colapsível e comparação com resultados de provas de carga em placa e em sapata / The utilization of a hand penetrometer in a collapsible soil and comparison with load tests in plate and in footing

Tsuha, Cristina de Hollanda Cavalcanti 26 September 2003 (has links)
O presente trabalho tem como objetivo avaliar a utilização de um penetrômetro manual para quantificar a resistência à penetração em um solo poroso e não-saturado. Os ensaios foram efetuados com monitoração de sucção, obtendo-se assim correlações entre resistência à penetração do penetrômetro e a sucção do solo. Os valores de tensão de ruptura obtidos nos ensaios penetrométricos foram comparados com valores de capacidade de carga de ensaios de placa e de provas de carga em sapatas realizados à mesma profundidade, no mesmo local, com medidas simultâneas de sucção. Finalmente, o trabalho comprova a influência da sucção nos resultados dos ensaios realizados / The objective of this work is to evaluate the use of a hand penetrometer to quantify the penetration resistance of a porous and unsaturated soil. The tests were done with suction monitoring, thus, it was obtained correlation between resistance of the penetrometer penetration and the soil suction. The values of rupture pressure obtained by the penetrometer tests were compared with values of bearing capacity of plate load tests and footing load tests, that were done at the same deep and at the same location, with suction measurement. Finally, this work proves the influence of the suction on the tests results
18

Desempenho de estacas escavadas de grande diâmetro em solo arenoso sob carregamento vertical / Bored pile performance of large diameter in sandy soil under vertical load

Nienov, Fabiano Alexandre January 2016 (has links)
Procura-se nesta pesquisa estudar o desempenho de estacas escavadas de grande diâmetro em solo arenoso sob diferentes métodos executivos (uso de polímero e bentonita). Um programa de provas de cargas instrumentadas em profundidade foi realizado para verificar o desempenho de estacas escavadas em solo arenoso sob carga vertical. O Campo Experimental em que se realizou o estudo localiza-se no município de Araquari, litoral Norte do Estado de Santa Catariana, Brasil. O perfil geotécnico é composto de areia compacta a fofa, intercalada por uma camada de argila de três metros de espessura entre os 18 e 22m de profundidade. Foram executas duas estacas escavadas de 1,0m de diâmetro e cota de apoio de 24,10m e 24,40m respectivamente com uso de polímero (Polymud) e bentonita. Os resultados das provas de carga demostraram diferença de desempenho entre as duas técnicas usadas. Realizaram-se duas provas de carga lenta para verificar o desempenho. Uma prova de carga em que a carga máxima resistida pela estaca com uso de bentonita foi de 4574kN gerando deslocamento de 63,5mm no topo da estaca. Outra prova de carga na estaca com uso de polímero em que a carga aplicada no topo da estaca foi de 8518kN a qual gerou um deslocamento no topo da estaca de 98,71mm. O desempenho do atrito lateral apresentado pela estaca com o uso de lama bentonítica foi inferior que a estaca em que foi usado polímero. Essa diferença foi maior na camada até de 0,0 m aos 11,0m iniciais. Nesses 11,0m iniciais o solo é composto por uma camada de areia fofa a pouco compacta até os 4,0m e dos 4,0m aos 11,0m areia compacta a muito compacta. Essa redução da resistência lateral na estaca com o uso de bentonita pode estar relacionado devido à formação de cake. Em relação ao desempenho da carga de ponta, as técnicas de execução não tiveram influência na capacidade de carga. / It has been sought in this research to study the performance of bored piles of large diameter in sandy soil under different executive methods (the use of polymer and bentonite). A testing program of instrumental loads in depth was conducted to verify the performance of bored piles in sandy soil under vertical load. The experimental field in which the study took place is located in the city of Araquari, coast of the state of Santa Catarina, Brazil. The geotechnical profile is composed by compact sand to soft, alternated with a layer of clay three meters thick between 18 and 22m deep. It’s been executed two bored piles of 1.0m diameter and depth of 24,10m and 24,40m respectively with use of polymer (Polymud) and bentonite. The results of load tests have shown performance difference between the techniques used. There were two tests of slow load to verify performance. A load test in which maximum load resisted by the pile with use of bentonite was 4574kN creating 63,5mm displacement at the top of the pile. Another proof load on the pile with the polymer used in the load applied to the top of the pile was 8518kN which an offset generated at the top of the pile 98,71mm. The performance of the lateral friction presented by the pile with the use of bentonite mud was lower than the pile which has been used polymer. This difference was greater in the layer up to 0.0m to 11,0m initials. In these initial 11,0m soil is composed from a soft layer of sand to slightly compact until 4,0m and from 4,0m to 11,0m compact sand to very compact. This reduction of lateral resistance in pile with the use of bentonite may be related to the formation of cake. Regarding to the toe load performance, technical execution had no influence on the load capacity.
19

Análise de comportamento de estaca barrete embutida em rocha. / Behavior analysis of a rock socket barrette pile.

Marcello Duarte Musarra 01 September 2014 (has links)
Para proporcionar menores prazos e custos, o projeto de ampliação da sede da Petrobras, na cidade de Salvador, estado da Bahia, contemplou estacas barretes de grandes dimensões para grandes capacidades de carga. Porém, para atingir as cargas escolhidas, foi necessário embutir as estacas no topo rochoso. Portanto, foram projetadas estacas barretes embutidas em rocha, escavadas com hidrofresa. Esta pesquisa apresenta o estudo de duas provas de carga estáticas executadas em uma mesma estaca barrete teste embutida em rocha, a fim de proporcionar um melhor entendimento de seu comportamento, assim como os principais fatores que influenciam resistência e deformabilidade. Em março de 2012, foram realizadas duas provas de carga estáticas na mesma estaca barrete teste embutida em rocha. Os ensaios foram executados a partir das metodologias normativas NBR 12131 (2006) e NBR 6122 (2010), com carregamentos lento e rápido, respectivamente e subsequentemente. No primeiro ensaio (lento), aplicou-se a carga máxima de 12 MN, enquanto que no segundo (rápido), aplicou-se a carga máxima de 14 MN. Os dados obtidos nos ensaios, de acordo com a bibliografia utilizada, são pioneiros no Brasil, por se tratar da primeira estaca barrete embutida em rocha com utilização de hidrofresa, submetida à prova de carga de desempenho. A estaca foi instrumentada em profundidade, o que propiciou a avaliação da distribuição de carga nas camadas atravessadas. Foram realizadas comparações entre resultados obtidos da instrumentação e do topo, por meio do repique elástico. Além da avaliação e interpretação dos dados obtidos nos ensaios de provas de carga estáticas, esta pesquisa apresenta previsões de comportamento, com diferentes conceitos, para estacas embutidas em rocha, sem reação de ponta, com intuito de comparar seus resultados com os obtidos nos ensaios. Em conjunto com as previsões, foram apresentados métodos para estimativa de adesão lateral na interface da estaca com o maciço rochoso. / To use high loads on foundations of the Petobras Headquarters, the designers chose the barrette pile with great dimensions and a few units compared with others types, to shorten the deadline and optimize costs. However, to reach these assumptions, it was necessary make the piles deeper than the soil strata, and, therefore, made a rock socket design. This research presents two static load tests study and analysis in the same barrette test pile, to forecast behavior and find resistance and strain influences. In March, 2012, two static load tests were made in the same barrette test pile located in Salvador Bahia, in Petrobras headquarters. The first essay was made according to a slow maintained test with 12 MN maximum compressive loads. The second essay was made immediately after, according to a quick load test and 14 MN maximum compressive loads. The data obtained from both tests, far as is known, were the first results on rock socket barrette pile in Brazil, using hydromill for the excavations in rock. The pile had depth instrumentation with expansible strain gages and an expanded polystyrene block below the cage, to make the tip useless. Beyond the data assessment and interpretation from static load tests, this research presents forecasting methods to only shear resistance rock socket piles, with the aim of comparison. Lastly but not least, side resistance empirical methods between pile and rock interface were presented.
20

[en] INSTRUMENTED LOAD TEST CARRIED OUT IN A PILED QUAY STRUCTURE / [pt] PROVA DE CARGA INSTRUMENTADA EM UM CAIS APOIADO SOBRE ESTACAS

ERIC ARTHUR DE FREITAS PENEDO 04 September 2018 (has links)
[pt] Esta dissertação apresenta os dados de um teste de carga instrumentado em um cais, enfatizando a importância da instrumentação de campo para melhor compreender o comportamento da estrutura durante o teste. Dentro desta abordagem, foi realizada uma revisão sobre o comportamento de grupo de estacas, direcionada à influência do espaçamento entre estacas na interação entre as mesmas, e da rigidez do bloco na distribuição de carga entre as estacas, no fator de segurança das mesmas e das distorções angulares do bloco. Em seguida, foram descritas as características geométricas e geotécnicas do cais testado, e foram apresentadas as características da instrumentação utilizada, composta por extensômetros elétricos, eletroníveis e nível topográfico, desde sua montagem e calibração, até a sua instalação em campo. Foi destacada a utilização dos eletroníveis, que apesar de pouco utilizados na prática da engenharia geotécnica, são instrumentos versáteis, precisos e podem ser reutilizados. O procedimento do teste de carga foi realizado de modo a simular a situação real da maneira mais próxima da realidade, onde foram monitoradas as deformações em quatro estacas, a rotação e o recalque da laje do cais. A estrutura apresentou bom desempenho durante o teste, com baixo nível de deformação nas estacas, distorção angular desprezível e baixos valores de recalque total e residual. / [en] This dissertation presents the data of an instrumented load test in a wharf, emphasizing the importance of field instrumentation to analyze the behavior of the structure during the load test. First, a review was carried out on the behavior of pile groups, focusing on the influence of pile spacing in the interaction factors. It also considered the influence of the raft stiffness on the load distribution and factor of safety of the piles. The main characteristics of the wharf were presented, such as, geometry, dimensions, deformability and strength properties of the concrete. The geological and geotechnical subsoil profile have been presented, indicating a soft clay layer resting on a very compact residual soil. The particularities of the instrumentation used on the test, composed by strain gauges, electrolevels and a topographic level, were presented since the assembly and calibration, to the installation on field. Despite its underutilization in geotechnical engineering practice, the use of electrolevels was emphasized, due to its versatility, accuracy and the fact that they can be reutilized. The load test procedure was made to simulate the real situation as close as possible, where strain in four piles, rotation and settlement of the deck were monitored. The structure performanced well during the test, presenting low level of strain in piles, negligible angular distortion of the deck and low values of total and residual settlements.

Page generated in 0.4626 seconds