• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 94
  • 1
  • Tagged with
  • 96
  • 96
  • 78
  • 69
  • 33
  • 30
  • 27
  • 27
  • 25
  • 21
  • 21
  • 20
  • 19
  • 18
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Avaliação da resistência lateral em estacas escavadas com trado submetidas à tração / Evaluation of the lateral strength in augered piles submitted traction

Bessa, Adevilson Oliveira de 24 June 2005 (has links)
Made available in DSpace on 2015-03-26T13:28:21Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1478030 bytes, checksum: 7ae901bf72afabae9de2beeb38c4248b (MD5) Previous issue date: 2005-06-24 / With the propose of determining and evaluating the lateral strength in excavated piles, without the usage of Bentonite mud, submitted to a traction effort. A number of field tests (PMT, DMT, SPT and SPT-T) and laboratory tests (triaxial compression, particle size analysis , consistency limits, density of soil particles), with what was possible to identify the composition of a matured residual soil composed by 64% of clay, 33% of sand and 3% silt. It was performed, in the Experimental Field II , localized at the Universidade Federal de Viçosa campus, axel pull tests in four piles with 6 m of length and 0,25 m in diameter, obtaining values of lateral strength that where used as reference values for the theatrical and semi-empirical methods values. These results where also compared with values of compression tests made with other four piles of the same diameter and length located in the same test field, in another recent research. This made possible identify the existence or not of a gap between the lateral strength of pull effort and the lateral strength of a compression effort. / Com a finalidade de determinar e avaliar a resistência lateral em estacas escavadas com trado sem o uso de lama bentonítica solicitadas à tração, foi executado neste trabalho uma série de ensaios de campo (PMT, DMT, SPT e SPT-T) e laboratório (granulometria conjunta, limites de consistência, massa específica dos sólidos e ensaios triaxiais), através dos quais foi possível identificar a composição de um solo residual maduro variando em torno de 64% de argila, 33% de areia e 3% de silte. Foram realizadas provas de carga estáticas à tração com esforço axial em quatro estacas com comprimento de 6 m e diâmetros de 0,25 m no campo experimental II localizado nas dependências da fábrica de manilhas no campus da Universidade Federal de Viçosa, obtendo valores de resistência lateral os quais serviram de referência quando da avaliação dos valores obtidos através de métodos teóricos e semi-empíricos. Foram comparados também os resultados obtidos nas provas de carga com os já existentes de provas de carga à compressão, de outro trabalho de mestrado que utilizou outras quatro estacas com as mesmas dimensões e no mesmo campo experimental das ensaiadas neste trabalho. Esta comparação possibilitou identificar a existência ou não de uma defasagem da resistência lateral à tração em relação à resistência lateral à compressão.
52

Comportamento de estacas escavadas de pequeno diâmetro em solo laterítico e colapsível da região de Campinas/SP / Behavior of bored piles of small diameter in collapsible and lateritic soil in the region of Campinas/SP

Scallet, Marcella Maschietto 17 August 2018 (has links)
Orientador: Miriam Gonçalves Miguel / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-17T14:10:40Z (GMT). No. of bitstreams: 1 Scallet_MarcellaMaschietto_M.pdf: 1855400 bytes, checksum: 6ec58c53afe478625fb1fa36239f671c (MD5) Previous issue date: 2011 / Resumo: Este trabalho tem como objetivo estudar o comportamento de estacas escavadas de pequeno diâmetro, submetidas a carregamentos axiais de compressão através de provas de carga estática realizadas no Campo Experimental de Mecânica dos Solos e Fundações 2 da Unicamp. O CEMSF2 apresenta um perfil geológico cuja primeira camada é constituída de argila siltosa, coluvionar, laterítica e colapsível. Pretendeu-se avaliar as capacidades de carga e os recalques dessas estacas nas condições: a) sem pré-inundação e sem melhoria de ponta; b) sem pré-inundação e com melhoria de 1 ponta, com o lançamento de um volume de 18 litros de brita 1 no fundo da estaca antes da concretagem; c) com pré-inundação e sem melhoria de ponta e d) com préinundação e com melhoria de ponta. Todas as estacas foram submetidas a dois carregamentos (ensaios e reensaios), sob uma mesma condição acima descrita. Foram instalados tensiômetros convencionais para a leitura das sucções matriciais do solo durante a realização das provas de carga. Através das curvas carga versus recalque foram definidas as capacidades de carga e as resistências ao atrito lateral e de ponta, por meio de métodos de interpretação dessas curvas com o solo sem inundação e préinundado por 48horas, considerando as reduções dos valores da sucção matricial do solo, devido às duas condições de umidade. A capacidade de carga das estacas nos ensaios foi menor do que nos reensaios, para as estacas sem pré-inundação, devido ao aumento da resistência de ponta nos reensaios. Nas provas de carga com préinundação, em geral, não houve aumento de resistência de ponta dos ensaios para os reensa ios. A resistência ao atrito lateral foi maior que a resistência de ponta em todas as provas de carga. O lançamento de brita 1 não trouxe melhorias na capacidade de carga. Reduções consideráveis na capacidade de carga foram observadas em função da pré-inundação do solo, sendo essas reduções mais expressivas para as estacas com melhoria de ponta / Abstract: This paper aims to study the behavior of bored piles of small diameters, subjected to axial compression loads by static load tests carried out at the Field of Experimental Soil Mechanics and Foundation 2 at Unicamp. The CEMSF2 has a geological profile whose first layer is composed of silty clay, with coluvionar, lateritic, and collapsible features.This study intended to evaluate the load capacities and the settlements of these foundations in such conditions: a) without any pre- wetting nor improvement in the tip; b) without any pre-wetting but with a tip improvement, placing a volume of 18 liters of stones 1 in the base of the pile before concreting c) with pre- wetting but without tip improvement and d) with pre-wetting and tip improvement. All these piles were subjected to two loading (tests and retests), under the same test condition described above. Conventional tensiometers were installed to read the matric suctions of the soil during the performance of the load tests. Throughout the load versus settlement curves the load capacities and the strength to lateral friction and tip were defined using methods of interpretation of these curves with the soil without any pre-wetting and 48-hour-pre wetting, considering the reductions of the values of the soil matric suction due to two moisture conditions. The load capacity of piles in the tests was smaller than the one in the retests for the piles without any pre-flooding, due to the increase of the tip strength in the retests. In the load tests with pre-flooding, in general, there was not any increase of strength in the tip of the tests for the retests. The strength to the lateral friction was greater than the tip strength in all loading tests. The placing stones 1did not result any improvement to the bearing capacity. Considerable reductions in bearing capacity were observed because of the pre-wetting soil, such reductions are more significant for the piles with improved tip / Mestrado / Geotecnia / Mestre em Engenharia Civil
53

Analise de provas de carga a compressão a luz do conceito de rigidez / Compression load test analyses based on concept of regidity

Melo, Barbara Nardi 13 August 2018 (has links)
Orientador: Paulo Jose Rocha de Albuquerque / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-13T04:04:46Z (GMT). No. of bitstreams: 1 Melo_BarbaraNardi_M.pdf: 6782464 bytes, checksum: 2db509605b90c7d9ce2ae5bbdafbb1c1 (MD5) Previous issue date: 2009 / Resumo: A dificuldade de se atingir a ruptura dos elementos de fundação nos ensaios estáticos fez com que, ao longo de várias décadas, diversos métodos de extrapolação da curva carga vs recalque fossem sugeridos por inúmeros pesquisadores, no intuito de determinar a carga de ruptura, destacando-se os métodos propostos por Van der Veen (1953), Mazurkiewics (1972), Décourt (1996) e NBR 6122/1996. Porém, a experiência confirma que os resultados podem variar consideravelmente entre um método e outro. Este trabalho destaca o Conceito de Rigidez proposto por Décourt (1996, 2008), método que, nos últimos anos, vem sendo utilizado pela comunidade geotécnica e é destacado pelo autor como um método que oferece informações de resistência de ponta e atrito lateral, além da carga de ruptura em provas de carga comuns, ou seja, sem instrumentação. Com a interpretação dos resultados, levantados em estacas do tipo escavadas, hélice contínua, raiz, ômega, pré-moldadas, apiloadas e metálicas em seis campos experimentais localizados nas cidades de Campinas/SP, Recife/PE, Vitória/ES, Londrina/PR, Ilha Solteira/SP e Brasília/DF obtiveram-se valores satisfatórios de carga de ruptura convencional em provas de carga levadas a grandes deslocamentos e algumas restrições em provas de carga interrompidas prematuramente. Os resultados de atrito lateral comparados com resultados de estacas instrumentadas trazem valores satisfatórios, ou seja, dentro dos domínios. / Abstract: The difficulty of reaching the rupture of the foundation elements in the static loading made that along several decades several methods of extrapolation of the load - settlement curve were suggested by many researchers, with the intent of determining the load failure, such as the methods proposed by Van der Veen (1953), Mazurkiewics (1972), Décourt (1996) and NBR 6122/1996. But the experience confirms that the obtained results can vary considerably from one method to another. This work details the Concept of Rigidity, proposed by Décourt (1996, 2008), a method that in the last years it has been used by the geotechnical community and which the author claims as a method that provides information on tip resistance and lateral friction, along with the load at failure in common load tests, it means, without instrumentation. Whit the interpretation results raised in bored piles, continuous flight auger, root, omega, driven concrete, "hamered" and metal pile in six experimental fields localized in Campinas/SP, Recife/PE, Vitória/ES, Londrina/PR, Ilha Solteira/SP and Brasilia/DF got satisfactory values of conventional load failure in load tests carried to big movements and some restrictions in load tests not carried to failure. The lateral friction results compared with load tests on instrumented piles results show satisfactory values, it means, in the domains. / Mestrado / Geotecnia / Mestre em Engenharia Civil
54

Estacas submetidas a esforços horizontais em solos colapsiveis do interior de São Paulo, nas condições natural, melhorada e inundada / Horizontally loaded piles in collapsible soils of the interior of the state of São Paulo, under the conditions of natural humidity, improved soil and pre-flooded soil

Miranda Junior, Gentil 12 November 2006 (has links)
Orientador: David de Carvalho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-09T05:45:20Z (GMT). No. of bitstreams: 1 MirandaJunior_Gentil_D.pdf: 36304791 bytes, checksum: 88909d0a8735e0e6ebf6251c718ba4cb (MD5) Previous issue date: 2006 / Resumo: O problema de estacas carregadas horizontalmente no topo é freqüente em obras de construção civil e há uma reduzida bibliografia sobre os parâmetros a serem adotados em projetos. Uma situação mais crítica é a de estacas carregadas horizontalmente em solos de alta porosidade, não saturados e colapsíveis. Os objetivos deste trabalho são: (1) proporcionar subsídios para o projeto de fundações com carregamento horizontal, chamando a atenção para o danoso efeito de uma inundação de um solo colapsível; (2) fornecer valores do coeficiente de reação horizontal ('n IND. h') para uma argila silto arenosa de alta porosidade, solo de diabásio, comum na região de Campinas, para condições de umidade natural, solo pré-inundado, solo melhorado com solocimento e solo-cimento pré-inundado; (3) compararos valores obtidos com valores de 'n IND. h' para solos freqüentemente encontrados no interior do Estado de São Paulo e em outras regiões do Brasil; (4) propor uma melhoria das condições do sistema solo-estaca através da troca do solo ao redor do topo da estaca por solo-cimento compactado. Para a análise deste problema, foram realizadas vinte e uma provas de cargas horizontais no Campo Experimental de Fundações da Unicamp, em catorze estacas de quatro tipos, nas quatro condições de solo citadas acima. E foram analisadas outras provas de carga realizadas em Campos Experimentais do Estado de São Paulo, todos localizados em regiões com solos superficiais com características desfavoráveis ao carregamento horizontal. Comparam-se valores do coeficiente de reação horizontal do solo ('n IND. h') para diferentes condições do solo, destacando-se a importância de se obter parâmetros do solo regionalmente. Os principais resultados encontrados foram, além dos valores de coeficiente de reação horizontal para o solo de basalto do local e a compilação de valores para solos de alta porosidade de outras regiões - encontrando-se valores diferentes dos propostos na bibliografia -, a acentuada redução do 'n IND. h' (valoresem tomo de 40 vezes menores) ocasionada pela préinundação do solo, o acentuado aumento do 'n IND. h'(valores em média 5 vezes maiores) com a melhora do solo através do solo-cimento compactado,e a redução do 'n IND. h' com a pré-inundação do solo-cimento (valores em média 7 vezes menores). Nota-se que a redução devido à préinundação do solo-cimento é bem inferior a da pré-inundaçãodo solo na umidade natural. Conclui-se que, num projeto onde há a atuação de esforços horizontais e presença de solo colapsível, é necessário contar com a possibilidade de uma inundação do solo, tomar medidas preventivas contra a mesma e utilizar parâmetros do solo adequados. Ou adotar soluções de melhoria do solo, como a utilização do solo-cimento compactado ao redor da cabeça da estaca, que também podem ser adotadas em casos de baixa resistência do solo superficial (seja o solo colapsível ou não) / Abstract: The problem with piles loaded horizontally at the top is frequently met in civil construction projects and there is a reduced bibliography on the parameters to be adopted in designoA more critical situation is that of horizontally loaded piles in high porosity, non saturated and collapsible soils. The objectives of this paper are: (1) produce subsidies for the design of foundations with horizontalloads, calling attention to the damaging effect of flooding on a collapsible soil; (2) supply values for the horizontal reaction coefficient ('n IND. h') for the soil of the Experimental Field at Unicamp, for the conditions of natural humidity, pre-flooded soil, soil improved with soil-cement and pre-flooded soil-cement; (3) compare values of nh for the soils frequently found in the interior of the State of São Paulo and in other regions in Brazil; (4) propose an improvement in the conditions of the soil-pile system soils by changing the soil around the top of the pile for compacted soil-cement. To analyze this problem, twenty one horizontal loading tests were made in the Experimental Foundation Field at Feagri-Unicamp, on fourteen piles of four types, under the four soil conditions mentioned above. Other loading tests made in Experimental Fields in the State of São Paulo were analyzed, alI of them located in regions with surface soils with unfavorable characteristics for horizontal loading. The coefficients of horizontal soil reaction ('n IND. h') for different soil conditions are compared, emphasizing the importance of obtaining regional soil parameters. The principal results found were, besides the values for the coefficient of horizontal reaction for the basalt soil at the location and the compilation of values for high porosity soils of other regions - encountering different values from °those proposed in literature - an accentuated reduction of nh (values around 40 times less) caused by the pre-flooding of the soil, the accentuated increase in 'n IND. h' values (as a mean, 5 times greater) with the soil improvement by compacted soil-cement and the reduction in 'n IND. h' with pre-flooding of the soilcement (mean values 7 times smaller). It is seen that the reduction due to pre-flooding of the soil-cement is much less than that for pre-flooding the soil at natural humidity. One concludes that in a project where horizontal forces act and in collapsible soil, one must count with the possibility of soil flooding, taking preventive measures against this and using adequate soil parameters or, adopt solutions for soil improvement, as by using compacted soil-cement around the pile head, a procedure which can also be adopted in cases of low surface soil resistance (collapsible soil or not) / Doutorado / Construções Rurais e Ambiencia / Doutor em Engenharia Agrícola
55

Comportamento de estacas tipo escavada e helice continua, submetidas a esforços horizontais / Behavior of bored and continuous flight auger piles under horizontal stress

Zammataro, Bruno Braz 27 February 2007 (has links)
Orientador: Paulo Jose Rocha de Albuquerque / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T17:50:50Z (GMT). No. of bitstreams: 1 Zammataro_BrunoBraz_M.pdf: 5071414 bytes, checksum: 81ca663defad90551f9f175888acb63f (MD5) Previous issue date: 2007 / Resumo: Nesta pesquisa estudou-se o comportamento de estacas tipo escavada e hélice contínua, submetidas a prova de carga estática horizontal. Estes elementos encontram-se instalados no Campo Experimental da Feagri, Unicamp, cujo perfil compõe-se de solo estratificado predominantemente argiloso, porém com comportamento de arenoso. Como objetivo principal, obtiveram-se valores de nh, para um intervalo escolhido e através de valores de deslocamento horizontal e carga aplicada. Além disso, obtiveram-se, para diversos métodos, valores de carga de ruptura e carga admissível horizontal, verificando sua validade / Abstract: The behavior of bored and continuous flight auger piles was studied, under static horizontal load. These elements are installed in the Feagri Experimental Field, at the Unicamp campus, with a soil section profile which is predominantly stratified clay, but behaving as sandy soil. The main objective was to obtain values for nh,for a chosen interval and through values of horizontal displacement and applied load. Besides this, for various methods, values were obtained for horizontal loading at rupture and safe loading, verifying their validity / Mestrado / Geotecnia / Mestre em Engenharia Civil
56

Uma nova metodologia de extrapolação dos dados da prova de carga dinâmica: MES-CASE / A new method of extrapolating data from the dynamic laod test: MES-CASE

ALVES, éder Chaveiro 26 February 2010 (has links)
Made available in DSpace on 2014-07-29T15:18:26Z (GMT). No. of bitstreams: 1 PRE TEXTO DISSERTACAO EDER.pdf: 124262 bytes, checksum: 341b7782cf7b9bd27e25fca751a05985 (MD5) Previous issue date: 2010-02-26 / Since 1983, when the experiment of dynamic load has been plunged in Brazil, the execution of this kind of experiment has become a common practice in foundation sites on precast inserted piles. In many cases the experiment of dynamic load doesn t mobilize the ultimate strength of the tested pile; the causes of these events may be due to: the available equipment at the site isn t capable of obtaining enough kinetic energy to mobilize the ultimate strength; the structural element presents ruptures; the client desire of not mobilizing all the ultimate strength; among others. Knowing the necessity of determining the ultimate strength in order to adapt the construction to the security factors required by NBR 6122/1996, this essay pursuits developing a methodology of extrapolation of the curve of mobilized static resistance versus the maximum displacement obtained through the dynamic load proof (dynamic load experiment of crescent energy), applying the Simplified Method CASE, to inserted precast piles. Studying 21 (twenty-one) proofs of dynamic load (PDL), an extrapolation methodology has been developed entitled as Simplified Extrapolation Methodology of CASE Method (SEM-CASE). The methodology is based on the criteria of complementary energy, presented by Aoki in 1997. The results have demonstrated that the method SEM-CASE has presented itself as easy manipulation. The estimated values of ultimate complementary strength calculated by the SEM-CASE has presented pretty close to the measured values, existing only one pile which presented a value error bigger than 10%. The estimated values of ultimate pile strength, obtained by the SEM-CASE, showed themselves similar to the measured values, also having a value error inferior to 10%. The exponential function has obtained better results of adjustment coefficient (R2) related to the points of the curve of mobilized static resistance versus the maximum displacement measured in the dynamic load proof. Besides, applying model selection criteria was obtained that the exponential function is more efficient to estimate the curve of mobilized static resistance versus the maximum displacement than the hyperbolic and parabolic functions. / Desde 1983, quando o ensaio de carregamento dinâmico foi introduzido no Brasil, a execução deste tipo de ensaio vem se tornando uma prática comum em obras de fundação em estacas de concreto pré-moldado cravadas. Em vários casos o ensaio de carregamento dinâmico não mobiliza a resistência última da estaca ensaiada, as causas desses eventos podem ser devido a: o equipamento disponível na obra não é capaz de obter energia cinética necessária para mobilizar a resistência última; o elemento estrutural apresenta rupturas; o cliente não desejar mobilizar toda resistência última; entre outros motivos. Sabendo a necessidade da determinação da resistência última, para a adequação da obra com os fatores de segurança exigidos pela NBR 6122/1996, este trabalho procura desenvolver uma metodologia de extrapolação da curva resistência estática mobilizada versus deslocamento máximo obtida pela prova de carga dinâmica (ensaio de carregamento dinâmico de energia crescente), empregando o Método Simplificado CASE, para estacas de concreto pré-moldado cravadas. Por meio de estudos de 21 (vinte e uma) provas de carga dinâmica (PCD), desenvolveu-se uma metodologia de extrapolação intitulada como Método de Extrapolação Simplificado do Método CASE (MES-CASE). A metodologia é baseada no critério da energia complementar, apresentada por Aoki em 1997. Os resultados demonstraram que o método MES-CASE apresentou-se de fácil manuseio. Os valores estimados de energia complementar última, calculados pelo método MES-CASE, apresentaram-se bem próximos dos valores medidos, havendo apenas uma estaca que apresentou valor de erro maior que 10%. Os valores estimados de resistência estática última, obtidos pelo método MES-CASE, mostraram-se semelhantes aos valores medidos, tendo também um erro inferior a 10%. A função exponencial obteve os melhores resultados de coeficiente de ajuste (R2) em relação aos pontos da curva resistência estática mobilizada versus deslocamento máximo medidos na prova de carga dinâmica. Além disso, empregando critérios de seleção de modelo obteve-se que a função exponencial é mais eficaz para estimar a curva resistência estática mobilizada versus deslocamento máximo do que as funções hiperbólica e parabólica.
57

Estudo do comportamento de solo não saturado através de provas de carga em placa / Study of the behavior of an unsaturated soil through plate load tests

Yuri Daniel Jatobá Costa 20 December 1999 (has links)
Este trabalho apresenta resultados de provas de carga em placa com monitoramento do teor de umidade e da sucção matricial do solo, realizadas a 1,5 m de profundidade em um solo não saturado e colapsível, considerado representativo da região centro-oeste do estado de São Paulo. Foram executados ensaios com e sem inundação da cava, do tipo lento (SML), rápido (QML) e misto (lento até um determinado estágio, passando a rápido a partir de então). O acompanhamento do teor de umidade e da sucção durante os ensaios foi realizado através de pesagem de amostras, com a utilização da técnica de reflectometria no domínio do tempo (TDR) e com o auxílio de tensiômetros. A partir dos dados obtidos, procedeu-se a uma análise da influência da sucção na resposta do sistema solo-placa. Foi observado que o aumento da sucção provoca um crescimento substancial da capacidade de carga do solo. Comparando-se ensaios inundados com não inundados, observou-se que o colapso do solo mostra-se mais proeminente com o aumento da sucção. Com respeito à técnica de reflectometria no domínio do tempo, a mesma demonstrou um desempenho satisfatório para medidas de teor de umidade in situ. / This work presents results of plate load tests with measurements of soil moisture content and matric suction, carried out at a 1.5 m depth in an unsaturated collapsible soil, considered as representative of the middle-west region of the state of São Paulo, Brazil. The tests were performed with and without the wetting of the pit. Three test methods were used: slow maintained load (SML), quick maintained load (QML), and mixed tests (SML up to a certain stage, switched to QML from there on). Soil moisture content and suction were measured through gravimetric determination on samples, the time domain reflectometry technique (TDR), and tensiometers. The gathered data allowed an assessment of the influence of the soil suction over the soil-plate system response. It was observed that the increase in suction causes a substantial increase in soil bearing capacity. Comparisons between wet and non-wet tests showed that soil collapse is higher when suction rises. The time domain reflectometry technique showed a promising performance with respect to in situ water content measurements.
58

Metodologia para a determinação da eficiência do ensaio SPT através de prova de carga estática sobre o amostrador padrão / Methodology to determine the SPT efficiency through static load test over the sampler

Luis Fernando de Seixas Neves 23 March 2004 (has links)
O ensaio de simples reconhecimento de solos (SPT) é a ferramenta de investigação de solos mais utilizada no mundo. Devido ao grande número de parâmetros que influenciam os seus resultados, a medida de sua eficiência passa a ser indispensável à transposição de experiências entre as práticas desenvolvidas em diferentes locais. Infelizmente, a medida da eficiência através da instrumentação do impacto do martelo é economicamente inviável para a maioria das empresas de sondagem no Brasil. Este trabalho apresenta uma metodologia para a determinação da eficiência do SPT baseada no princípio de Hamilton e na realização de prova de carga estática sobre o amostrador, que pode ser uma alternativa para sanar esta situação. / The standard penetration test (SPT) is the most used soil investigation tool in the world. Due to the great number of variables that influences its results, the measurement of the efficiency becomes imperative to the transposition of experiences between developed practices in different places. Unfortunately, the measurement of the efficiency through the instrumentation of the hammer impact is economically inpracticable to most of the soil investigation firms in Brazil. This work presents a methodology to determinate the SPT efficiency based on the Hamilton\'s principle and on the execution of static load test over the sampler, what seems to be a good alternative to end this situation.
59

Novo procedimento para a realização de análise capwap no ensaio de carregamento dinâmico em estacas pré-moldadas. / New prodedure to perform CAPWAP analysis on dinamic load test in precast concrete piles.

Murakami, Daniel Kina 01 October 2015 (has links)
Desde a década de 1980 diversos autores apresentaram correlações entre provas de carga estática e ensaios de carregamento dinâmico em estacas. Para uma boa correlação é fundamental que os testes sejam bem executados e que atinjam a ruptura segundo algum critério, como o de Davisson, por exemplo, além de levar em conta o intervalo de tempo entre a execução da prova de carga estática e do ensaio dinâmico, face ao efeito \"set up\". Após a realização do ensaio dinâmico realiza-se a análise CAPWAP que permite a determinação da distribuição do atrito lateral em profundidade, a carga de ponta e outros parâmetros dos solos tais como quakes e damping. A análise CAPWAP é realizada por tentativas através do procedimento \"signal matching\", isto é, o melhor ajuste entre os sinais de força medido pelos sensores e o calculado. É relativamente fácil mostrar que a mesma solução pode ser obtida através de dados de entrada diferentes. Isso significa que apesar de apresentarem cargas mobilizadas próximas o formato da curva da simulação de prova de carga estática, obtida pelo CAPWAP, assim como a distribuição do atrito lateral, podem ser diferentes, mesmo que as análises apresentem \"match quality\" (MQWU) satisfatórios. Uma forma de corrigir o formato da curva simulada do CAPWAP, assim como a distribuição do atrito lateral, é através da comparação com provas de carga estática (PCE). A sobreposição das duas curvas, a simulada e a \"real\", permite a determinação do quake do fuste através do trecho inicial da curva carga-recalque da prova de carga estática, que por sua vez permite uma melhor definição da distribuição do atrito lateral e da reação de ponta. Neste contexto surge o conceito de \"match quality de recalques\" (MQR). Quando a PCE não está disponível, propõe-se efetuar um carregamento estático utilizando o peso próprio do martelo do bate-estaca (CEPM). Mostra-se, através de dois casos de obra, em que estavam disponíveis ensaios de carregamento dinâmico e PCEs, que esse procedimento permite obter uma melhor solução do ponto de vista físico, isto é consistente com as características do subsolo e com a curva carga-recalque da PCE, e não apenas matemático, através da avaliação do \"match quality\" (MQWU). / Since the 1980s a lot of authors showed correlations between static load tests and dynamic load tests on piles. For a good correlation it is necessary a good execution of the load test, also it is necessary to choose a capacity value from the results of the static load test, for example, the Davisson Offset limit load. The time of execution between the static load test and the dynamic load test should be considered because of the set up effect. Dynamic data may be further analyzed by CAPWAP Method to evaluate the soil resistance distribution, the toe resistance, quake and damping values. It is a signal matching method. Its results are based on the \"best possible match\" between computed pile top variable such as the pile top force and its measured equivalent. It is easy to demonstrate almost the same pile capacity on CAPWAP using different soil parameters. It means that even the pile capacity is almost the same, the shape of the pile top load-displacement of the CAPWAP Method and the shaft friction distribution can be different, although all results confirm good match quality. One way to correct the shape of the top loaddisplacement of the CAPWAP Method, as well as the shaft friction distribution, is by comparisson to a static load test. Overlaying both curves, the static load test and the CAPWAP Method, it is possible to determine the shaft quake value on the initial loads on the top load-displacement curve, allowing this way a improvement of the shaft resistance distribution and the toe resistance. In this context arises the concept of \"match quality of settlements\". When the static load test is not avaliabe, this thesis proposes a static load test using the hammer\'s weight of the pile driving machine. It is shown by two case studies that were available static load tests and dynamic load tests, this procedure allows a better solution on physics aspects, this is consistent with the subsoil conditions and the load-settlement curve of the static load test, not only a mathematical solution based on match quality.
60

Análise de prova de carga dinâmica em estacas metálicas do tipo trilho / Analysis of dynamic load tests on steel crane rail piles

Lima, Floriano Medeiros de Andrade 21 December 1999 (has links)
Este trabalho apresenta a análise de provas de carga dinâmica realizadas em estaca metálicas tipo trilho (TR - 68) cravadas no Campo Experimental de Fundações da USP/São Carlos. As estacas possuem segmentos de 12 e de 3 m, soldados segundo a NBR 8800/86, totalizando um comprimento máximo 27 m. Os objetivos desta análise são: 1) realizar um estudo abrangente da capacidade de carga do tipo trilho, 2) verificar a utilização de trilho usado como elemento estrutural de fundação, 3) comprovar o uso do repique como método de controle do estaqueamento, 4) demostrar a importância da energia crescente na prova de carga dinâmica. As medidas de repique foram realizadas com o uso de papel e lápis em vinte estacas, para níveis crescentes de energia. A energia foi aplicada pelo martelo de gravidade caindo de uma altura de 0,20 - 0,40 - 0,60 - 0,80 - 1,00 - 1,20 e 1,50 m. A capacidade de carga das estacas, determinada pela extrapolação da curva carga mobilizada - deslocamento, foi comparada com os valores obtidos pelos métodos de previsão da prática brasileira, bem como com os resultados de dois ensaios com PDA (Pile Driving Analyzer) e também com uma prova de carga estática, realizados em estacas representativas. / This paper presents an analysis of dynamic load tests performed on steel crane rails piles (TR-68) at the Experimental Foundation Field of USP/São Carlos. The piles have segments of 12 and 3 m, welded according to NBR 8800/86, comprising a maximum driving length of 27 m. The objectives of this analysis are: 1) to carry out a wide study of steel track pile bearing capacity, 2) verify the utilization of the steel crane rails piles with structural element of foundation, 3) to prove the use of the rebound with the control method of driving piles. 4) to demonstrate the importance of increasing energy in the dynamic load test. The rebound measurements were performed with paper and pencil in twenty piles and were analyzed by applying increasing energy level. The energy was applied by the gravity hammer falling of a drop heights of 0.2 - 0.4 - 0.6 - 0.8 - 1.0 - 1.2 and 1.5 m. The pile bearing capacity, determined by the extrapolations of the mobilized resistance - displacement curves was compared to the Brazilian experience methods, as well as to two load tests employing the Pile Driving Analyzer (PDA) and to one static load test carried out on representative piles.

Page generated in 0.4827 seconds