Spelling suggestions: "subject:"hspice"" "subject:"pspice""
11 |
Design and Modeling of High Performance LED Dimming Driver with Reduced CurrentSpikes using Turn-On Snubber across Power MOSFETBorra, Venkata Shesha Vamsi 17 June 2014 (has links)
No description available.
|
12 |
On-line pspice based simulation of DC electrical engineering circuitsReddy, Smitha 01 April 2001 (has links)
No description available.
|
13 |
Aplikace moderních funkčních bloků v harmonických oscilátorech / Application of modern active blocks in harmonic oscillatorsVotýpka, František January 2010 (has links)
This work deals with using modern active functional blocks in electronic circuits. These blocks have better features than classical operational amplifiers and are characterized especially by working in current mode. Therefore these blocks can be used in higher frequencies. Using those blocks it is possible to design e.g. electronically variable-frequency filters of types low-pass filter, high-pass filter, band-pass filter, etc. Then it is also possible to easily realize electronically variable-frequency oscillators. This work is focused on some of these blocks, their basic characteristics and principles. Also three oscillators with current conveyors of second generation are designed. Its made simulation, sensitivity and tolerance analysis and magnitude stabilization. Everything is performed in OrCAD PSpice program. These made oscillators are electronic tunable in the band frequency ones of MHz.
|
14 |
Contribuição para o estudo da impedância sob impulso, área efetiva, coeficiente de impulso e resistência de malhas de aterramento de subestações / not availableJoaquim, Luiz Eduardo 27 March 1997 (has links)
O conhecimento da área efetiva de uma malha de aterramento de subestação elétrica é importante para obter o valor da impedância sob impulso num determinado ponto da malha em situações de incidência de descargas atmosféricas e determinar o nível de impulso básico (NBI). A partir destes valores é possível definir com segurança a disposição dos equipamentos no interior da subestação. Com o objetivo de obter um modelo de malha de aterramento de subestações. são estudadas malhas de aterramento com formas geométricas quadradas até sessenta e quatro sub-malhas e retangulares até setenta e duas sub-malhas. Para análise do comportamento em regime permanente na freqüência industrial e transitório é proposto um modelo de uma linha de transmissão em π, com indutâncias próprias e mútuas e condutâncias lineares. As simulações são feitas em microcomputador e estação de trabalho utilizando o software PSPICE. As correntes em regime permanente ou impulsiva são aplicadas no canto ou no centro das malhas. Suas características são as seguintes: o freqüência de sessenta Hertz: o frente de onda de três micro-segundos; o tempo de cauda de quarenta micro-segundos. A partir das curvas V x I obtidas nas simulações são colhidas as resistências na freqüência industrial e impedância sob impulso, e são calculadas as diferenças percentuais. São comparados os resultados obtidos nas simulações com aqueles obtidos por Gupta e Thapar e Gupta e Singh. Estes pesquisadores desenvolveram fórmulas empíricas para a determinação da tensão induzida no ponto de aplicação de corrente, coeficiente de impulso e área efetiva. / The knowledge of the cffective area of a grounding grids of electrical substation is important when one are trying to know the impulse impedance value proceeding atmospheric discharges, as well as of the basic insulation level in a specific point of the grid. Having as propose the finding of a appropriated model of grounding grid are studied grounding grids with square geometric forms, from four until sixty four meshes and and rectangular geometric forms from four until seventy two meshes. As a way to analyze the behavior of the parameters in steady state at industrial frequency and in transient condition is proposed-a π-model transmission line with self and mutual inductance and linear conductances. The simulations are clone by microcomputer and workstation, using the PSPICE software. The currents in steady state or impulse are applied at the corner or at the center of the grids. Their characteristics are the follow: o frequency: sixty hertz; o waveform rise time: three micro-seconds; o waveform fall time: forty micro-seconds. From the V x I curves attained during the computer simulations it is found the values of the resistance industrial frequency and impulse impedance and are calculated the percentile differences. Are compared the results found during the computer simulation with the simulations attained by Gupta and Thapar and Gupta and Singh. These mentioned authors developed some empirical equations for determination of the induced voltage at the point where the impulse current is applied, of the impulse coefficient and of the effective area.
|
15 |
Contribuição para o estudo da impedância sob impulso, área efetiva, coeficiente de impulso e resistência de malhas de aterramento de subestações / not availableLuiz Eduardo Joaquim 27 March 1997 (has links)
O conhecimento da área efetiva de uma malha de aterramento de subestação elétrica é importante para obter o valor da impedância sob impulso num determinado ponto da malha em situações de incidência de descargas atmosféricas e determinar o nível de impulso básico (NBI). A partir destes valores é possível definir com segurança a disposição dos equipamentos no interior da subestação. Com o objetivo de obter um modelo de malha de aterramento de subestações. são estudadas malhas de aterramento com formas geométricas quadradas até sessenta e quatro sub-malhas e retangulares até setenta e duas sub-malhas. Para análise do comportamento em regime permanente na freqüência industrial e transitório é proposto um modelo de uma linha de transmissão em π, com indutâncias próprias e mútuas e condutâncias lineares. As simulações são feitas em microcomputador e estação de trabalho utilizando o software PSPICE. As correntes em regime permanente ou impulsiva são aplicadas no canto ou no centro das malhas. Suas características são as seguintes: o freqüência de sessenta Hertz: o frente de onda de três micro-segundos; o tempo de cauda de quarenta micro-segundos. A partir das curvas V x I obtidas nas simulações são colhidas as resistências na freqüência industrial e impedância sob impulso, e são calculadas as diferenças percentuais. São comparados os resultados obtidos nas simulações com aqueles obtidos por Gupta e Thapar e Gupta e Singh. Estes pesquisadores desenvolveram fórmulas empíricas para a determinação da tensão induzida no ponto de aplicação de corrente, coeficiente de impulso e área efetiva. / The knowledge of the cffective area of a grounding grids of electrical substation is important when one are trying to know the impulse impedance value proceeding atmospheric discharges, as well as of the basic insulation level in a specific point of the grid. Having as propose the finding of a appropriated model of grounding grid are studied grounding grids with square geometric forms, from four until sixty four meshes and and rectangular geometric forms from four until seventy two meshes. As a way to analyze the behavior of the parameters in steady state at industrial frequency and in transient condition is proposed-a π-model transmission line with self and mutual inductance and linear conductances. The simulations are clone by microcomputer and workstation, using the PSPICE software. The currents in steady state or impulse are applied at the corner or at the center of the grids. Their characteristics are the follow: o frequency: sixty hertz; o waveform rise time: three micro-seconds; o waveform fall time: forty micro-seconds. From the V x I curves attained during the computer simulations it is found the values of the resistance industrial frequency and impulse impedance and are calculated the percentile differences. Are compared the results found during the computer simulation with the simulations attained by Gupta and Thapar and Gupta and Singh. These mentioned authors developed some empirical equations for determination of the induced voltage at the point where the impulse current is applied, of the impulse coefficient and of the effective area.
|
16 |
Zařízení pro zpracování audio signálu pomocí signálového procesoru / Device for audio signal processing by means of signal processorLev, Lukáš January 2012 (has links)
Master´s work discusses the issue of processing audio signal by means of signal processor. At present, the signal processor occurs in almost all devices that process or somehow modify sound in digital form. The aim of this master´s thesis is to study the signal processors from different producers, which are now on the market and select one suitable type for device that will process the audio signal. With this signal processor then propose a circuit diagram for a device that will process the audio signal and the PSpice simulation of the circuit and construct this device.
|
17 |
Estudio y modelización en régimen permanente de cargas no lineales para el análisis armónico de redes eléctricasBoix Aragonès, Oriol 20 December 1996 (has links)
El análisis armónico de redes eléctricas se utiliza para el estudio de los efectos de las cargas no lineales sobre las magnitudes y formas de onda de las tensiones y corrientes eléctricas. Dado el constante incremento de las cargas no lineales respecto a las lineales, este estudio tiene cada vez mayor importancia.En el caso de redes eléctricas lineales el método de estudio mayormente utilizado es el flujo de cargas, por tanto es lógico utilizar también un flujo de cargas para el caso no lineal; entonces es necesaria una modelización de las cargas no lineales para su incorporación en el estudio.Después del análisis bibliográfico se observa que la mayoría de los autores utilizan métodos sin interacción armónica, es decir, no tienen en cuenta la influencia que ejercen sobre la forma de onda de la corriente los armónicos de tensión del punto de conexión de la carga. En este trabajo se presenta un ejemplo de los errores numéricos y de forma de onda que se introducen al no tener en cuenta la interacción armónica.Otros autores utilizan métodos con interacción armónica pero modelizando una única carga no lineal: el rectificador trifásico con filtro inductivo alimentado con un sistema simétrico de tensiones; pero hay otras cargas no lineales de importancia en las instalaciones eléctricas que, aunque son de menor potencia unitaria, el número de unidades en una misma instalación es considerable dando lugar a una potencia total importante.En esta tesis se presenta un método sistematizado para la obtención de modelos de cargas no lineales y los modelos obtenidos para ocho cargas, tanto para los casos de simetría de semionda y simetría trifásica como para el caso general. Todos los modelos han sido exhaustivamente ensayados con alimentación a tensión constante con resultados satisfactorios.Para una fácil implementación en un programa de flujo de cargas se ha determinado el sistema de ecuaciones a resolver para cada carga y se han hallado las expresiones algebraicas de las constantes internas de cada modelo y de los desarrollos armónicos de las intensidades. Se incluye también el método de obtención de la primera aproximación para el método de Newton o de h-Newton que deberá resolver el sistema.Se incluyen los resultados de una muestra significativa de los numerosos casos ensayados con el método de flujo de cargas y en simulaciones a tensión constante. Se han comparado muchos resultados con los que se obtienen con métodos en el dominio del tiempo (PSPICE) y en algunos casos reales.
|
18 |
Control of Double Inverted Pendulum First ApproachDABRETAU, Teerapong, DAREINI, Ali January 2015 (has links)
An Inverted double pendulum is a combination of two individual pendulums which represents an example of a nonlinear and unstable dynamic system and it is also a good example of a physical system which can exhibit chaotic behavior.This document contains a first analysis of the model and the control of this system. Also presented is the installation of the electrical materials needed to control the system contain instrumenting the motor, current measurement system, motor shaft angle sensor, vision systemand MYRIO which is an embedded hardware device created by National Instruments will be used for data acquisition and control the system
|
19 |
Prise en Compte du Câblage dans la Conception et la Simulation des Convertisseurs de Puissance: Performances CEMTeulings, Wim 29 April 1997 (has links) (PDF)
Un des défis de l'Electronique de Puissance moderne est la Compatibilité Electromagnétique (CEM). Devant l'accroissement de la rapidité de commutation, le câblage devient un composant à part entière. Il doit donc être modélisé. L'objectif de ce travail est de montrer qu'il est possible à l'heure actuelle de simuler entièrement un convertisseur moderne, en tenant compte des imperfections dues au câblage (simulation fine). Les formes d'ondes en commutation obtenues sont suffisamment précises pour prédire les performances vis-à-vis de la CEM. Cependant, ce type de simulation est relativement long, et cette approche doit être réservée à la vérification de l'implantation technologique [male. Elle ne peut servir d'aide au concepteur. C'est pourquoi des modèles analytiques plus simples sont développés à partir de l'analyse des résultats de simulation fine. Ces modèles, d'une bonne précision, font intervenir des paramètres technologiques, et peuvent servir d'aide à la conception. Les deux approches ont été appliquées à un convertisseur réalisé sur Circuit Imprimé et en technologie Substrat Métallique Isolé (SMI). L'influence d'une capacité de découplage sur le niveau des perturbations conduites a également été examinée dans les deux cas.
|
20 |
Dynamický model synchronního stroje s využitím magnetických ekvivalentních obvodů / Dynamic model of synchronous machine with magnetic equivalent circuitSvetlík, Martin January 2011 (has links)
The thesis focuses on constructing dynamic model - synchronous generator with using magnetic equivalent circuit diagrams. The model construction is based on knowledge of geometric parameters, magnetic characteristic of used material and fyzical deployment of vindings placed in stator slots. Computed reults are compared with results optained from model created with finite element method.
|
Page generated in 0.0418 seconds