Spelling suggestions: "subject:"cualidade dde ar"" "subject:"cualidade dee ar""
201 |
Avaliação dos aspectos físico-químicos e microbiológicos para determinação do índice de qualidade da água – IQA no Rio Toledo – PR / Evaluation of the physical-chemical and microbiological aspects for determination of the water quality index - WQI in the Toledo River - PRTaborda, Juliana 03 March 2017 (has links)
Submitted by Marilene Donadel (marilene.donadel@unioeste.br) on 2017-09-28T23:10:43Z
No. of bitstreams: 1
Juliana_Taborda_2017.pdf: 1612081 bytes, checksum: ae11d6b79482fb4ba5976f56e7eb651e (MD5) / Made available in DSpace on 2017-09-28T23:10:43Z (GMT). No. of bitstreams: 1
Juliana_Taborda_2017.pdf: 1612081 bytes, checksum: ae11d6b79482fb4ba5976f56e7eb651e (MD5)
Previous issue date: 2017-03-03 / Fundação Araucária de Apoio ao Desenvolvimento Científico e Tecnológico do Estado do Paraná (FA) / The Toledo river has its route in both rural and urban areas, being subject to different forms of environmental impacts. Changes in water characteristics may be related to the use and occupation of the soil in the vicinity of the river, generating anthropogenic processes. Thus, the purpose of this work was to analyze the water quality of the Toledo River in order to verify the effects of urbanization and agricultural activities under the water body. The Water Quality Index (WQI) and cadmium trace elements, lead, manganese, nickel and zinc were used. The WQI was calculated, according to the methodology proposed by CETESB (2015), where the physical variables were obtained: turbidity and water temperature; Chemical variables: BOD; pH; Dissolved oxygen; Total nitrogen and total phosphate; Biological variables: fecal coliforms. Limnological analyzes were performed following the methodology described in APHA (2005). The values of the analyzes were compared to those established by the Conama Resolution nº 357/2005, for Class II waters. The concentrations of the trace elements were obtained through the ICP-OES equipment by acid digestion. In order to do this, monthly water collections were carried out in five distinct points, three points located in the rural region, and two points in the urban region, during the period from July 2015 to June 2016, totaling one year of monitoring. The WQI values at the five collection points ranged from (78.06 to 36.44). Point 1 had an annual average of (67.75) and point 4 (39.92). Points 4 and 5 showed critical points regarding contamination of organic origin (BOD), phosphate (total phosphate) and microbiological (fecal coliforms). The values obtained exceeded the limits established by the legislation in force in practically all monitoring. These values allowed to classify the water body in the categories of Regular to Good. The trace elements presented in all points values discordant of the limits recommended by the resolution Conama no 357/2005 for waters of Class II. The analysis of land use and occupation showed that the urban area occupies an area of 2,902.93 (Ha), totaling 2.42% of occupancy. The agricultural area occupies 98,643.02 (Ha), with 82.33% of area in use. In this way the use and occupation of the soil improperly can directly influence the quality and availability of water resources, either by accelerated urbanization, by the suppression of vegetation or by the use of agriculture. Impacts may vary depending on the use, organic load, nutrients, metallic contaminants and sediment trapping, compromising the quality and balance of the aquatic ecosystem. / O rio Toledo tem seu percurso tanto na área rural quanto urbana, estando sujeito a diferentes formas de impactos ambientais. As alterações das características da água podem estar relacionadas ao uso e ocupação do solo nas proximidades do rio, gerando processos antropogênicos. Sendo assim, o propósito deste trabalho foi analisar a qualidade da água do rio Toledo, a fim de verificar os efeitos da urbanização e atividades agrícolas sob o corpo hídrico. Foi utilizado o Índice de Qualidade de Água (IQA) e análise dos elementos traço cádmio, chumbo, manganês, níquel e zinco. O IQA foi calculado, de acordo com a metodologia proposta pela CETESB (2015), onde foram obtidas as variáveis físicas: turbidez e temperatura da água; variáveis químicas: DBO; pH; oxigênio dissolvido; nitrogênio total e fosfato total; variáveis biológicas: coliformes fecais. As análises limnológicas foram realizadas seguindo a metodologia descrita em APHA (2005). Os valores das análises foram comparados aos estabelecidos pela resolução Conama nº 357/2005, para águas de Classe II. As concentrações dos elementos traço foram obtidas através do equipamento ICP-OES por digestão ácida. Para tanto, foram realizadas coletas de água mensais, em cinco pontos distintos, três pontos localizados na região rural, e dois pontos situados na região urbana, durante o período de julho de 2015 á junho de 2016, totalizando um ano de monitoramento. Os valores de IQA nos cinco pontos de coleta variaram de (78,06 á 36,44). O ponto 1 obteve uma média anual de (67,75) e o ponto 4 (39,92). Os pontos 4 e 5 mostraram-se pontos críticos com relação à contaminação de origem orgânica (DBO), fosfatada (fosfato total) e microbiológica (coliformes fecais). Os valores obtidos ultrapassaram os limites preconizados pela legislação vigente em praticamente todo o monitoramento. Estes valores permitiram classificar o corpo hídrico nas categorias de Regular a Boa. Os elementos traço apresentaram em todos os pontos valores discordantes dos limites recomendados pela resolução Conama no 357/2005 para águas de Classe II. A análise de uso e ocupação do solo demosntrou que, a região urbana ocupa uma área de 2.902,93 (Ha), totalizando 2,42% de ocupação. A área agrícola ocupa 98.643,02 (Ha), com 82,33% de área em uso. Dessa maneira o uso e ocupação do solo de forma inadequada pode influenciar diretamente na qualidade e na disponibilidade dos recursos hídricos, seja pela urbanização acelerada, pela supressão da vegetação ou pelo uso da agricultura. Os impactos podem variar em função do uso, aporte de carga orgânica, nutrientes, contaminantes metálicos e o arraste de sedimentos, comprometendo a qualidade e o equilíbrio do ecossistema aquático.
|
202 |
Efeito da carga orgânica volumétrica sobre a produção de biogás utilizando-se dejeto de suíno em diferentes configurações de reatores anaeróbios / Effect of organic loading rate on the biogas yield swine manure in different anaerobic reactors configurationsLins, Marcos Araújo 13 July 2017 (has links)
Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2018-02-09T18:33:17Z
No. of bitstreams: 2
Marcos_Lins2017.pdf: 1306769 bytes, checksum: e562bcb30c504f3ac5e0a7e12446e473 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-02-09T18:33:17Z (GMT). No. of bitstreams: 2
Marcos_Lins2017.pdf: 1306769 bytes, checksum: e562bcb30c504f3ac5e0a7e12446e473 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-07-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The use of anaerobic reactors with energetic purposes is an effective decision-making to treat swine farming wastewater. But, the applied organic loading rate (OLR)must be correct, since itvaries according to the reactor configuration and other process conduction conditions, such as temperature. Thus, this trial aimed at showing the effect of OLR progression on biogas generation and quality of swine manure in anaerobic reactors as continuous stirred tank reactor (CSTR), covered lagoon digester (CLD) and upflow anaerobic sludge blanket (UASB).The experiment with CSTR reactor of 17-L useful volume, semicontinuously fed at 37 ± 1 °C, was divided into three phases. In the first phase, a constant OLR was applied with 1.0 g VS add L-1reactor d-1 until biogas productivity was stable. This occurred after the fortieth day of operation. In phase II, the OLR progressions had begun, starting with 2.0 g VS add. L-1reactor d-1 and after stabilizing biogas production rate, OLR was increased to 3.0 g VS add. L-1 reactor d-1. In phase III, OLR answers were 1.0, 1.9 and 0.7 g Vs add. L-1reactor d-1 and submitted in this order, according to the hydraulic retention time (HRT) in order to identify the relation among these variables. In the trial with CLD of 17-L useful volume, and semicontinuously fed, OLR answers were 0.3, 0.4 and 0.5 g VSadd. L-1reactor d-1, respectively. The experiment with theUASB reactor of 6.6-L useful volume, continuously fed at 37 ± 1 °C, was divided into two phases. In phase I, OLR answers were:1.5, 2.0, 2.5 and 3.0 g VSadd L-1reactor d-1. In phase II, OLR answers were 0.5, 0.7, 1.0, 1.4, 1.6, 2.2, 2.9 and 8.4 g VS add. L-1reactor d-1.For CSTR reactor, the best results of methane content and biogas production rate was in OLR 1.9 g VS add. L-1reactor d-1 and HRT of 15 days, with 53 ± 10% (v v-1) and 0.7 ± 0.1 LNbiogas L-1reactord-1, respectively. In the experiment with CLD reactor, the best results of methane content and biogas production rate was in OLR 0.5 g VS add L-1reactor d-1 and HRT of 34 days, with 61 ± 5% (v v-1) and 0.3 ± 0.1 LN biogas L-1reactor d-1, respectively. For the UASB reactor, the best result of methane content and biogas production rate was in OLR 2.9 g VS add. L-1reactor d-1 and HRT of 1.5 days, with 74 ± 1% (v v-1) and 1.6 ± 0,5 LN biogas L-1reactor d-1, respectively. This research aimed at understanding the effect of OLR progression on the biogas production rate up from DS, establishing a relation among other variables that affect this biofuel production, contributing with important information to choose the most available reactor configuration to be settled in a full scale. / O uso de reatores anaeróbios com finalidades energéticas é uma forma eficiente para o tratamento de efluentes da suinocultura, desde que seja aplicada a correta carga orgânica volumétrica (COV), que varia de acordo com a configuração do reator e demais condições de condução do processo, tais como a temperatura. Assim, o objetivo deste trabalho é demonstrar o efeito de progressão da COV sobre a geração e qualidade do biogás a partir de dejetos de suínos em reatores anaeróbios do tipo:Continuous stirred tank reactor (CSTR), biodigestor de lagoa coberta (BLC) e Upflow anaerobic sludge blanket (UASB). O experimento com o reator CSTR de 17 L de volume útil, alimentado de forma semicontínua a 37 ± 1°C foi dividido em três fases. Na fase I, foi submetida COV constante de 1,0 g SV adic L-1 reator d-1 até estabilização da produção de biogás, que ocorreu a partir do quadragésimo dia de operação. Na fase II, iniciaram-se as progressões de COV, começando com 2,0 g SV adic. L-1reator d-1 e após estabilização da produtividade de biogás, a COV foi elevada para 3,0 g SV adic. L-1 reator d-1. Na fase III, as COV 1,0, 1,9 e 0,7 g SV adic. L-1reator d-1, submetidas nesta ordem, foram controladas pelo tempo de retenção de hidráulica (TRH), com o objetivo de identificar a relação entre essas variáveis. No experimento com o BLC de 17 L de volume útil, alimentado de forma semicontínua, foram submetidas as COV 0,3, 0,4 e 0,5 g SV adic L-1 reator d-1, respectivamente. O experimento com o reator UASB de 6,6 L de volume útil, alimentado de forma contínua a 37 ± 1°C, foi dividido em duas fases. Na fase I,foram submetidas as COV: 1,5, 2,0, 2,5 e 3,0 g SV adic L-1 reator d-1. Na fase II, foram submetidas as COV: 0,5, 0,7, 1,0, 1,4, 1,6, 2,2, 2,9 e 8,4 g SV adic L-1 reator d-1. Para reator CSTR, os melhores resultados de teor de metano e produtividade de biogás foram na COV de 1,9 g SV adic L-1 reator d-1 e TRH de 15 dias, com 53 ± 10% (v v-1) e 0,7 ± 0,1 LN biogás L-1 reator d-1, respectivamente. No experimento com o BLC, os melhores resultados de teor de metano e produtividade de biogás foram na COV 0,5 g SV adic L-1 reator d-1 e TRH de 34 dias, com 61 ± 5% (v v-1) e 0,3 ± 0,1 LN biogás L-1reator d-1, respectivamente. Para reator UASB, os melhores resultados de teor de metano e produtividade de biogás foram na COV 2,9 g sv adic L-1 reator d-1 e TRH de 1,5 dias, com 74 ± 1% (v v-1) e 1,6 ± 0,5 LN biogásL-1reator d-1, respectivamente. Esta pesquisa possibilitou compreender o efeito da progressão de COV sobre a produção de biogás a partir de DS, estabelecer relação com outras variáveis que afetam a produção deste biocombustível e contribuir com informações importantes para a escolha da configuração de reator, mais adequada para a implantação em escala real.
|
203 |
Qualidade do ar interno com ênfase na concentração de aerodispersóides nos edifícios. / The indoor air quality in the buildings with an emphasis on the concentration of particulates matters.Alexandre Perri de Moraes 28 June 2006 (has links)
No presente trabalho, é avaliada a qualidade do ar interno com ênfase na concentração de aerodispersóides presentes em edifícios comerciais e residenciais com sistema de ventilação natural ou condicionamento de ar. De fato, algumas doenças de origem ocupacional são causadas pela inalação de aerodispersóides nocivos à saúde. O método utilizado para avaliar a qualidade do ar interno nos edifícios comerciais e residenciais consistiu primeiramente em caracterizar os medidores de aerodispersóides e em seguida passou-se para a análise das concentrações e das características ambientais. A pesquisa mediu a concentração de aerodispersóides em edifícios com sistemas de ventilação diferentes (1a fase), e identificou as principais fontes de emissão de aerodispersóides em um apartamento residencial (2a fase). Observou-se que as concentrações obtidas na pesquisa estão acima dos valores recomendados na RE n° 9 (ANVISA, 2003) e por Morawska et al. (1999) que atribuem valores de 80 µg/m³ e 7.400 part./cm³, para concentrações médias em massa e em número, respectivamente. Com base nas observações acima, chegou à conclusão que as concentrações médias em massa e em número de aerodispersóides, durante as atividades domésticas (cozimento, reforma, limpeza, entre outras), foram várias vezes maiores do que as concentrações obtidas em ambientes com atividades profissionais ou com menor ocupação durante o dia. / This paper is the result of quality evaluation of indoor air quality with emphasis on the concentration of aerodispersoid in commercial and residential buildings with natural ventilation or air conditioning systems. In fact, some of the occupational diseases are caused by the inhalation of aerodispersoids hazardous to health. The method applied to evaluate the indoor air quality in commercial and residential buildings consisted firstly of characterizing the aerodispersoid measuring devices and subsequently analyzing the concentration levels and environmental characteristics. This research measured the concentration of aerodispersoids in buildings equipped with a variety of ventilation systems (phase1) and next it identified the main emission sources in a residential apartment (phase 2). It was observed that the concentration levels measured were above the specifications recommended by RE n° 9 (ANVISA, 2003) and by Morawska et al. (1999) which attribute values of 80 µg/m³ and 7.400 part./cm³, for average concentration in mass and number respectively. Based on the above information it was concluded that the average concentration levels of aerodispersoids in mass and number in home related activities (cooking, restoration, cleaning, etc) were many times higher than the concentration levels found in business environments or in environments with less occupation during the day.
|
204 |
Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.Renata Maria Marè 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
|
205 |
Compostos orgânicos voláteis em tintas imobiliárias: caracterização e efeitos sobre a qualidade do ar em ambientes internos construídos / Volatile organic compound in paints: characterization and effects on air quality in indoor environments builtLyda Milena Patiño Guío 28 November 2013 (has links)
Materiais de construção como: adesivos, selantes, aglomerados, compensados, carpetes, revestimentos de parede, isolamentos, forros acústicos etc., emitem compostos orgânicos volateis (COVs) em ambientes internos (Niu e Burnett, 2001). No caso da tinta no Brasil, Salasar (2006) indica que \"as tintas à base de solventes emitem 520 vezes mais COVs em relação às tintas à base de água\". Consequentemente aumentos significativos na concentração de poluentes químicos e biológicos do ar em ambientes internos são provocados pelas baixas taxas de troca de ar em conjunto com a emissão de COVs originados pelos materiais de construção dos ambientes internos (Gioda & Neto, 2003). O objetivo nesta pesquisa é identificar compostos orgânicos volateis nas emissões de tintas imobiliárias usadas em ambientes internos na cidade de São Carlos. O laboratório foi realizado com o equipamento de cromatografia gasosa acoplado a espectrometria de massas, com siglas GC/MS, junto com o aparelho para extração da amostra chamado de micro extração de fase sólida (SPME), para duas amostras de cada tinta sendo uma fresca (úmida) e outra seca. O laboratório GC/MS quando é utilizado com micro extração de fase sólida (SPME) é o método mais aproximado do ideal, já que permite qualificar os COVs contidos nas amostras de tinta com maior eficiência que qualquer outro método (Koziel & Pawliszym, 2001). A escolha das tintas, esmaltes e o verniz foram determinadas como aquelas de maior uso e venda entre os pintores e lojas de tintas, respectivamente, na cidade de São Carlos. Os resultados mostraram que as tintas podem chegar a emitir juntas mais de 61 compostos orgânicos voláteis, a maior parte deles causa irritação respiratória e cinco desses compostos são suspeitos de desenvolver câncer, a concentração de cada composto não foi determinada. Uma suposição é que a saúde dos pintores pode estar sendo afetada, pois eles têm contato constante com as emissões das tintas, neste sentido é preocupante que esses trabalhadores da construção civil sejam informais, pois nesta condição o risco à sua saúde pode ser agravado devido à falta de capacitação necessária sobre a utilização do material que estão manipulando. Parte do resultado da pesquisa mostra também por meio de um questionário, as marcas de tintas imobiliárias comumente usadas na cidade de São Carlos, assim como uma noção sobre as doenças que as tintas produzem. O questionário foi elaborado para 40 pessoas entre pintores e vendedores de lojas de tinta na cidade de São Carlos. As fichas de segurança de produtos químicos FISPQ correspondentes para cada tinta omitem informações sobre alguns ingredientes considerados de risco encontrados nas amostras de tintas, como por exemplo, compostos suspeitos de desenvolver câncer. É importante para o Brasil a criação com urgência de um selo ambiental confiável que garanta a baixa concentração de emissão de COVs nas tintas como produto, mediante valores quantificáveis. Se similar ao selo \"Green Seal\", o mesmo daria não só uma forma de controle sobre a emissão de COVs nos prédios senão confiabilidade e garantia. O selo será um parâmetro de exigência nas certificações ambientais para confirmar as baixas emissões de COVs nos materiais das edificações sustentáveis, que até agora são inexistentes. / Building materials such as: Adhesives, sealants, plywood, carpeting, wall coverings, insulation, acoustic ceilings etc., emit volatiles organic compounds (VOCs) in indoor environments (Niu e Burnett, 2001). In the case of the paint in Brazil, Salasar (2006) indicates that \"solvent-based paints emit VOCs 520 times as compared to water-based paint.\". Consequently significant concentration of chemical and biological pollutants from indoor air, are caused by low rates of air exchange in conjunction with the emission of VOCs originating from the construction of the indoor materials (Gioda & Neto, 2003). The objective of this research is to identify volatile organic compounds (VOC) emissions from architectural coatings used indoors in São Carlos. The laboratory was performed with gas chromatography equipment coupled to mass spectrometry with acronyms GC/MS, with the instrument for sample extraction called solid phase micro extraction (SPME) for two samples of each paint: a fresh (wet) and a dry. The GC/MS laboratory when used with solid phase micro extraction (SPME) is the closest to the ideal method, allows to qualify the VOCs contained in the paint samples more efficiently than any other method (Pawliszym & Koziel, 2001). The choice of paints, enamels and varnish were determined as those of greater use and sale among painters and paint stores, respectively, in the city of São Carlos. The results showed that the paint can issue more than 61 volatile organic compounds, most of them cause respiratory irritation and five of these compounds are suspected of developing cancer, the concentration of each compound was not determined. One of the hypotheses is that the health of painters may be being affected, as they have constant contact with emissions from paints,in this respect it is wrong that these workers of the construction are informal, because in this condition the risk to your health can be aggravated due to lack of necessary training on the use of the material. Part of the search result also shows by means of a questionnaire , the marks of paints commonly used in the city of São Carlos, as well as a notion about the diseases that produce the paints. The questionnaire was designed in 40 people between painters and sellers of paint shops in the city of São Carlos. Safety data sheets for chemicals corresponding MSDS for each paint omit some information about ingredients considered risk in samples of paints, such as examples, compounds suspected of developing cancer. It is important for Brazil to urgently create a reliable environmental seal that ensures low emission concentration of VOCs in paints and product through quantifiable values . If the seal is similar to the seal \"Green Seal\", it would not only a form of control over the emission of VOCs in buildings too reliability and warranty The stamp will be a requirement parameter in environmental certifications to confirm low emissions of VOCs in materials of sustainable buildings , which until now are nonexistent.
|
206 |
[en] AIR QUALITY ASSESSMENT IN RIO DE JANEIRO: FROM THE OLYMPIC GAMES TO THE PANDEMIC / [pt] AVALIAÇÃO DA QUALIDADE DO AR NO RIO DE JANEIRO: DAS OLIMPÍADAS À PANDEMIAELIZANNE PORTO DE SOUSA JUSTO 25 May 2022 (has links)
[pt] Este trabalho teve como finalidade o estudo dos níveis da composição
química do MP2,5 e MP10 e gases coletados em áreas urbanas-costeiras, a fim de
avaliar o impacto dos Jogos Olímpicos Rio 2016 e pandemia na qualidade do ar
na Região Metropolitana do Rio de Janeiro. Os resultados mostraram o aumento
de MP2,5 e MP10 devido às atividades urbanas desenvolvidas durante os Jogos
Olímpicos e as obras que ainda estavam sendo realizadas no primeiro semestre de
2016. Em todas as estações as espécies inorgânicas refletiram a influência de
aerossóis secundários e contribuições marinhas. As espécies Fe e Cu foram os
elementos mais abundantes encontrados nas partículas, detectados principalmente
em MP10. As fontes de emissão no MP10 foi obtido através do Positive Matrix
Factorization (PMF); quatro fontes de aerossóis foram identificadas nos locais:
veicular, spray marinho, formação secundária e um misto de ressuspensão do solo
e industrial. Um total de 37 HPA foram determinados e a concentração média da
soma dos 16 HPA considerados prioritários representou > 30 %. Para a maioria
das estações, a distribuição foi caracterizada pela predominância de compostos
com massa molecular entre 252 e 276. Em relação a pandemia, os resultados
mostraram que o bloqueio parcial afetou os níveis de poluentes por meio da
redução das emissões. Foram observadas a diminuição nos poluentes SO2, NO2 e
CO; enquanto houve um aumento na concentração de O3. No geral, o bloqueio
parcial contribuiu para a melhoria da qualidade do ar na cidade do Rio de Janeiro. / [en] This work aimed to study the levels of the chemical composition of PM2.5
and PM10 and gases collected in urban-coastal areas, in order to assess the impact
of the Olympic Games and the pandemic on air quality in Rio de Janeiro. The
results showed the increase of PM2.5 and PM10 due to urban activities developed
during the Olympic Games and the works that were still being carried out in the
first half of 2016. In all sites inorganic species reflected the influence of
secondary aerosol and marine contributions. The vehicular emitted species Fe and
Cu were the most abundant elements found in the particles, mostly detected in
PM10. The source apportionment was obtained with Positive Matrix Factorization
(PMF); four aerosol sources were identified at the sites: vehicular, marine spray,
secondary formation and a mix of industrial and soil resuspension. A total of 37
PAHs were analyzed. The average concentration of the 16 PAHs sum considered
priority represented > 30 %. For most stations, the distribution was characterized
by the predominance of compounds with a mass between 252 and 276. Regarding
the pandemic, the results showed that the partial lockdown affected pollutant
levels by reducing sources emission. A decrease in SO2, NO2, and CO was
observed; while there was an increase in O3 concentration. Thereby, the partial
lockdown contributed to improving air quality in Rio de Janeiro City.
|
207 |
[pt] DESENVOLVIMENTO DE SISTEMA DE MONITORAMENTO MULTIPARAMÉTRICO DA QUALIDADE DO AR EM AMBIENTES INTERNOS / [en] DEVELOPMENT OF A MULTIPARAMETRIC INDOOR AIR QUALITY MONITORING SYSTEMTHIAGO LEITE CAVALCANTE 10 June 2021 (has links)
[pt] O tema qualidade do ar em ambientes internos é de suma importância para a sociedade devido ao seu impacto na saúde humana, e pela maior permanência de indivíduos em ambientes sem circulação de ar natural. Este trabalho descreve o desenvolvimento de um sistema portátil e de baixo custo para monitoramento de grandezas atmosféricas ligadas à qualidade do ar em ambientes internos, composto por sensores integrados a unidades locais, incluindo um sistema remoto hospedado na nuvem para armazenar os resultados das medições desses sensores. Apresentam-se as diretrizes e documentos normativos e regulatórios relacionados ao tema, além das tecnologias para sensoriamento utilizadas. Após o desenvolvimento e caracterização dos sensores, as unidades foram distribuídas em ambientes universitários com distintas dinâmicas de uso, onde o gradiente espacial das grandezas atmosféricas foi avaliado e analisado segundo os requisitos para qualidade do ar publicados na regulamentação vigente. Com o monitoramento multiparamétrico identificou-se a heterogeneidade da distribuição dos valores das grandezas, dependente da dinâmica de ocupação e das condições de ventilação, especialmente para as concentrações de CO2. Este parâmetro superou os valores recomendados pela agência reguladora em todos os ensaios realizados em sala de aula, e maiores valores mostraram-se fortemente associados à região do espaço mais próxima das vias aéreas superiores dos ocupantes. Os resultados apontam para a importância de monitoramento contínuo e em vários pontos de um plano posicionado a uma distância estratégica do piso, conforme a dinâmica de ocupação e posição média da emissão de gases pelo processo respiratório. / [en] The topic of indoor air quality is of paramount importance to society due to its impact on human health and the increasing number of individuals staying in environments with no natural air circulation. This work describes the development of the system, low-cost and portable, for monitoring atmospheric quantities linked to indoor air quality, composed of sensors integrated into local units, including a remote system hosted in the cloud to store the results of measurements of these sensors. The normative and regulatory guidelines and documents related to the theme are presented, in addition to the sensing technologies used. After the development and characterization of the sensors, the units were distributed in university environments with different dynamics of use, where the spatial gradient of the atmospheric quantities was evaluated and analyzed according to the requirements for air quality published in the current regulation. With multiparametric monitoring, the heterogeneity of the distribution of the values of the quantities was identified, depending on the dynamics of occupation and ventilation conditions, especially for CO2 concentrations. This parameter exceeded the values recommended by the regulatory agency in all tests performed in the classroom, and higher values were shown to be strongly associated with the region of space closest to the occupants upper airways. The results point to the importance of continuous monitoring and at various points in a plane positioned at a strategic distance from the floor, according to the dynamics of occupation and the average position of the emission of gases by the respiratory process.
|
208 |
Análise de metodologias de determinação da viabilidade de implantação de tecnologias, técnicas e práticas, para gerenciamento de emissões de material particulado, na Região Metropolitana de São Paulo / Analysis of methodologies for determining the feasibility of implementing technologies, techniques and practices for the particulate matter management of emissions in the Metropolitan Region of São PauloRocha, Priscila Freire 19 June 2019 (has links)
A gestão da qualidade do ar é um desafio global, considerando que em muitos países, como no Brasil, a concentração da população em regiões metropolitanas é relevante, assim como sua exposição à poluentes atmosféricos. No estado de São Paulo, ao longo dos anos, as regulações que integraram a gestão da qualidade do ar têm incorporado novos instrumentos, exigências. Porém, identifica-se a ausência de procedimentos oficiais para auxiliar a concepção de políticas públicas. O objetivo deste trabalho foi de analisar metodologias existentes nos Estados Unidos da América e União Europeia, que possam auxiliar o planejamento de políticas públicas de qualidade do ar, em especial, para material particulado na Região Metropolitana de São Paulo (RMSP) e também de análises de viabilidade técnica e econômica de implantação de novas tecnologias, técnicas e práticas, do inglês Best Available Techniques (BAT)/ Best Environmental Practices (BEP). Por meio de pesquisa exploratória, utilizando-se de revisão bibliográfica e documental, este trabalho verificou a ausência sistemática de elementos como: análises de custo-efetividade de políticas públicas, consideração de modelagens integradas para concepção de políticas públicas, envolvimento de partes interessadas no planejamento de medidas. Quanto aos elementos para realizar análise de viabilidade técnica de implementação de BAT/BEP, foi possível identificar aspectos de avaliação de efeitos cruzados ambientais e econômicos, bancos de dados americanos e europeus contendo BAT/BEP e seus custos, que, com a devida adaptação, poderiam ser também uma referência. Trata-se de elementos importantes para subsidiar tomadas de decisão e buscar medidas, para que possam, de fato, levar à melhoria da qualidade do ar, para material particulado (MP10). / Air quality management is a global challenge, considering that in many countries, such as Brazil, the concentration of population in metropolitan regions is relevant and also their exposure to air pollutants. In the state of São Paulo, over the years, regulations that have integrated air quality management have incorporated new instruments, requirements. However, it is identified the absence of official procedures to assist the design of public policies. The objective of this work was to analyze existing methodologies in the United States and the European Union, which can assist in the planning of air quality public policies, especially for particulate matter in the Metropolitan Region of São Paulo (RMSP), as well as technical and economic feasibility analyzes for implementation of new technologies, techniques and practices from Best Available Techniques (BAT) / Best Environmental Practices (BEP). Through an exploratory research, using a bibliographical and documentary review, this work verified the systematic absence of elements such as: cost-effectiveness analysis of public policies, consideration of integrated modeling for public policy design, stakeholder involvement in planning of measures. As for the elements to perform technical feasibility analysis of BAT / BEP implementation, it was possible to identify aspects of environmental and economic cross-effects evaluation, American and European databases containing BAT / BEP and their costs, which, with due adaptation, could also be a reference. Those are important elements to support decision-making and seek measures, so that they can, in fact, lead to improved air quality for particulate matter (PM10).
|
209 |
Avaliação da qualidade ambiental interior de um edifício climatizado artificialmente com ênfase na análise do conforto térmico / Evaluation of indoor environmental quality of an artificially conditioned building, focusing on thermal comfort analysisSilva, Ana Flávia Silveira 25 November 2010 (has links)
Ocupantes de ambientes internos climatizados artificialmente estão expostos contínua e prolongadamente a condições ambientais muitas vezes desfavoráveis à execução de suas atividades e à manutenção da saúde. O objetivo desta pesquisa foi avaliar alguns parâmetros de qualidade do ar interior e de conforto térmico de um edifício climatizado artificialmente e relacioná-los à utilização de sistema de condicionamento de ar com distribuição pelo piso em ambientes que não são caracterizados como escritórios abertos. Considerando que o edifício estudado apresenta usos distintos de seus pavimentos, optou-se pela avaliação de dois deles, um pavimento cujo layout é de salas de aula e outro de escritório semi-aberto. Os parâmetros foram analisados em três momentos distintos. O primeiro se caracteriza por três ciclos semestrais de medições de temperatura, umidade relativa e velocidade do ar, concentração de aerossóis, dióxido de carbono e fungos. A segunda etapa consiste em uma campanha única de medições, com duração de quatro dias, permitindo a realização de perfis de temperatura e umidade relativa, avaliação das velocidades do ar em pontos de desconforto e cálculo dos índices de conforto térmico PMV (Predicted Mean Vote) e PPD (Predicted Percentage of Dissatisfied). Em um terceiro e último momento, aplicou-se o questionário de qualidade ambiental interior aos ocupantes de ambos os pavimentos. Resultados obtidos nos ciclos permitiram identificar concentrações de fungos e dióxido de carbono acima dos limites indicados. Os perfis de temperatura revelaram a predominância das mesmas abaixo do recomendado. O cálculo dos índices PMV e PPD apontaram para um cenário de maior conforto térmico nos ambientes estudados com temperatura operativa igual a 24 graus Celsius. Os resultados dos questionários corroboraram as medições de temperatura, indicando a prevalência das sensações térmicas relacionadas ao frio entre os ocupantes do edifício, em especial aqueles do sexo feminino. Ficou evidenciado que o conforto térmico nos ambientes pesquisados é um fator perturbador das atividades exercidas em ambos os pavimentos. Houve um grande número de relatos de ocupantes com sintomas típicos da Síndrome dos Edifícios Doentes (SED), sugerindo que medidas relativas à qualidade ambiental devem ser tomadas em prol da saúde, bem estar e produtividade dos ocupantes do edifício. Concluiu-se que a operação e manutenção do sistema de condicionamento de ar com insuflamento pelo piso em ambientes distintos de escritórios abertos são mais complexas e, por isso, dificultam o alcance de uma qualidade ambiental interior satisfatória. / Occupants of artificially conditioned indoor spaces are continuously and lengthily exposed to environmental conditions mostly adverse to their activities performance and health maintenance. The purpose of this research was to evaluate some indoor air quality and thermal comfort parameters of an artificially conditioned building, and relate them to the employment of underfloor air conditioning system in spaces that differ from open-plan office spaces. Considering the studied building presents different activities on each of its floors it was necessary to choose two of them, one characterized by classrooms layout and the other by a semi open-plan office layout. The on-site data collection took place in three different steps. Step one was distinguished by three six-month cycles of air temperature, relative humidity and air velocity measurements, and fungi, particulate matter and carbon dioxide concentrations. The second step consisted of a four-day single campaign of measurements, when air temperature and relative humidity profiles were carried out, air velocity was quantified in complaining areas, and the Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD) thermal comfort indexes were determined. During the third and last step, indoor environmental quality questionnaire surveys were distributed to the occupants of both studied floors. Data analysis and assessment originated from the cycles identified exceeding fungi and carbon dioxide concentrations. Temperature profiles indicated their prevalence below the recommended range. PMV and PPD indexes determination pointed to a scenery of best thermal environmental conditions for the researched spaces, with an operative temperature of 24 Celsius degrees. The results of the questionnaire surveys supported the air temperature measurements, showing supremacy of cold related thermal sensations among the occupants, especially those of female gender. It was evident that the thermal comfort of the studied environments is a disturbing factor for the activities practiced on both floors. There was a great number of occupants reporting Sick Building Syndrome (SBS) typical symptoms, what suggested actions related to indoor environmental quality should be taken in order to provide the desired health, welfare and productivity for the building occupants. It was conclusive that the operation and maintenance of underfloor air conditioned systems in indoor environments unlike open-plan offices are more complex and therefore make it harder to reach an acceptable indoor environmental quality.
|
210 |
Análise espaçotemporal da qualidade do ar em vias urbanas por meio de redes de sensores com nós embarcados em ônibus coletivos. / Spacio-temporal analysis from air quality in urbvan streets by wireless sensor networks with node hosted on public transport buses.Santos, Alessandro Santiago dos 08 December 2017 (has links)
Os veículos que compõem o tráfego urbano são considerados como o principal agente causador de poluição afetando diretamente a qualidade do ar nas cidades, sendo um desafio ter mecanismos de monitoramento que possibilitem uma visão geral das condições ambientais. Para proporcionar uma visão abrangente seria necessário um grande número de estações fixas de monitoramento da qualidade do ar, além de um incremento constante para acompanhar o crescimento da cidade. Neste cenário, surge a oportunidade de instrumentação de ônibus coletivo com sensores que medem a qualidade do ar durante seu trajeto, assim aproveitando as características de mobilidade do transporte público, o qual transita em áreas povoadas, com postura dinâmica de crescimento, adaptando-se de forma coerente à mutabilidade populacional e geográfica da cidade. A presente tese apresenta novas formas de realizar análises espaçotemporais da qualidade do ar de regiões urbanas. Os modelos cartográficos criados permitem analisar regiões mapeadas usando perspectivas espaciais e temporais com informações obtidas de kits sensores móveis, para análises a cada 100 metros, promovendo uma resolução maior que os modelos tradicionais de monitoramento (escala quilométrica), os quais ainda não oferecem esta possibilidade. Esta maior resolução permite uma nova perspectiva de análises de microrregiões e, desta forma, permite que os especialista ou gestores urbanos possam entender melhor as situações, ao utilizarem as ferramentas e recursos apresentados pela presente tese. Para atingir os objetivos optou-se pela criação e validação de um kit sensor para ser hospedado em ônibus coletivo, o qual foi validado e testado, quanto à sua eficiência de medição. Este kit foi integrado a uma plataforma computacional construída para extrair e processar informações com algoritmos matemáticos. Todos os componentes da plataforma foram legitimados com experimentos que confirmaram as hipóteses inicialmente formuladas para validação. E por fim, mapeamentos com mais de 70 mil pontos foram utilizados na criação de modelos espaçotemporais para realização de estudo de caso de regiões da cidade de São Paulo, os quais demostraram os usos potenciais das proposições desta tese. / The vehicles in urban traffic are considered as the main cause of urban pollution with a direct impact on air quality, being a challenge to have monitoring tools that enable an overview of the environmental conditions influenced by vehicle emissions. One option is to instrument the entire city with low-cost fixed sensors to collect environmental data; however, to provide a comprehensive view would require a large number of sensors, and a constant increase to follow the growth of the city. In this scenario, arises the opportunity for urban bus instrumentation with sensors that measure the environmental pollution, to take advantage of the mobility characteristics of public transport, which moves in populated areas, with dynamic attitude of growth, adapting in a coherent way to population and geographic variability of the city. This PhD Thesis proposes the monitoring of air quality inside urban roads by Wireless Sensor Networks (WSN), hosted on city buses. Thus, new ways of performing spatiotemporal analyzes of the air quality of urban regions are possible with the cartographic models created by this thesis. These allow to analyze mapped regions using spatial and temporal perspectives with information obtained from mobile sensor kits, for analyzes every 100 meters, promoting a resolution higher than the traditional monitoring models (kilometer scale), which still do not offer this possibility. This higher resolution allows a new perspective of analyzes of micro regions and, in this way, allows specialists or urban managers to have a better understanding of the urban scenario. Sensor kits are created to be hosted by bus, which has been validated and tested for its efficiency in measurement. This was integrated into a computational platform built to extract and process information with mathematical algorithms. All the components of the platform were validated with experiments that confirmed the hypotheses originally formulated for validation. Finally, mappings with more than 70,000 points were used in the creation of spatiotemporal models for the study of the case of regions of the city of São Paulo, which denoted the potentials constructed by this thesis.
|
Page generated in 0.085 seconds