• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 6
  • 2
  • Tagged with
  • 217
  • 217
  • 125
  • 124
  • 60
  • 42
  • 38
  • 38
  • 36
  • 33
  • 33
  • 32
  • 29
  • 27
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Sazonalidade de ondas planetárias nos ventos meteóricos observados em São João do Cariri-PB e em Cachoeira Paulista-SP

Araújo, Luciana Rodrigues de 13 December 2012 (has links)
Made available in DSpace on 2015-09-25T12:20:43Z (GMT). No. of bitstreams: 1 PDF - Luciana Rodrigues de Araujo 1.pdf: 6080043 bytes, checksum: f2c4bfe7b110393a5d25bdd1471786f0 (MD5) Previous issue date: 2012-12-13 / Dynamical characteristics of the terrestrial mesopause region can be observed from the atmospheric fields, such as wind and temperature. The purpose of this study was to contribute to a better understanding of mesopause dynamics of the equatorial and low latitude regions in the southern hemisphere, through the characterization of the wind flow between 80 and 100 km altitude. In this study we used wind observation data from mesosphere and lower thermosphere region (MLT), obtained from meteor radar measurements at São João do Cariri (7.4° S, 35° W) from July 2004 to December 2008 and at Cachoeira Paulista (22.7° S, 45.0° W) from January 2002 to July 2006 and from September 2007 to November 2008. From the spectral and harmonic analysis it was possible to identify presence of planetary-scale oscillations in the mean winds for two latitudes and to study their transient character, which allowed to elaborate a climatology of planetary oscillation signatures. The planetary wave with periods near 2-day, 6-7 days, 16 days and the 3-4 days equatorial waves, also known as ultra fast Kelvin wave, were focused in this study. The 2-day waves in the meteoric winds showed a seasonal cycle, with intense amplitudes after the southern summer solstice until the end of season, the 6-7 day oscillations had more intense amplitudes during August-November and presence with lower amplitudes during April-May in both sites. The 16-day oscillations showed no clear seasonality over C. Paulista, however, the Cariri amplitudes were intense from spring until mid-summer and weak from autumn until early austral winter. The 3-4 day oscillations showed amplifications intermittent throughout the year and it was not possible to identify a seasonal cycle over two sites. / As características dinâmicas da região próxima à mesopausa terrestre podem ser observadas a partir dos campos atmosféricos, como é o caso do vento e da temperatura. O propósito do estudo foi o de contribuir para o melhor entendimento da dinâmica da região próxima a mesopausa equatorial e em baixas latitudes do hemisfério sul, através da caracterização do escoamento entre 80 e 100 km de altitude. Para tanto, foram utilizadas nesta pesquisa observações de ventos na região da alta mesosfera e baixa termosfera (MLT - Mesosphere and Lower Thermosphere), obtidos a partir de medidas por radar meteórico, em São João do Cariri (7,4 S; 35,0 O) no período de julho de 2004 a dezembro de 2008 e em Cachoeira Paulista (22,7o S; 45,0o O) de janeiro de 2002 a julho de 2006 e de setembro de 2007 a novembro de 2008. A partir das análises de espectro e harmônica foi possível identificar a presença de movimentos de escala planetária nos ventos médios para as 2 latitudes e estudar o caráter transiente dos eventos, o que permitiu elaborar uma climatologia das assinaturas de oscilações de escala planetária. Foram focalizadas as ondas planetárias de 2 dias, 6-7 dias, 16 dias, além das ondas equatoriais de 3-4 dias; também conhecidas como ondas de Kelvin ultra rápidas. A onda de 2 dias apresentou um ciclo sazonal nos ventos meteóricos, com amplitudes intensas após o solstício de verão austral até o final da estação, as oscilações de 6-7 dias tiveram amplitudes mais intensas durante agosto-novembro e presença com amplitudes de menor intensidade em abril-maio, em ambas as localidades. As oscilações de 16 dias não apresentaram clara sazonalidade nos ventos de C. Paulista, entretanto, sobre Cariri foram mais intensas entre a primavera até meados do verão e amplitudes mais fracas entre o outono até início do inverno austral. As oscilações de 3-4 dias apresentam amplificações intermitentes ao longo do ano e não foi possível identificar um ciclo sazonal nas regiões MLT nas duas localidades.
132

Avaliação química, ecotoxicológica e genotoxicológica de águas e sedimentos de cavas de mineração a céu aberto / Chemical, ecotoxicological and genotoxicological evaluation of waters and sediments of open pit mine lakes

Bárbara, Viníciu Fagundes 27 March 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-24T12:13:14Z No. of bitstreams: 2 Tese - Viníciu Fagundes Bárbara - 2017.pdf: 2916938 bytes, checksum: e3841362774c4c7ee6cde936621d4747 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-24T12:13:45Z (GMT) No. of bitstreams: 2 Tese - Viníciu Fagundes Bárbara - 2017.pdf: 2916938 bytes, checksum: e3841362774c4c7ee6cde936621d4747 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-24T12:13:45Z (GMT). No. of bitstreams: 2 Tese - Viníciu Fagundes Bárbara - 2017.pdf: 2916938 bytes, checksum: e3841362774c4c7ee6cde936621d4747 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-27 / The mining industry is known to trigger intense environmental impacts. When the exploitation is done in the open, pit lakes are formed, units still little known in environmental terms, and increasingly common in several countries. Demonstrating complex behavior, open pit lakes differ greatly from natural lakes, what makes their management a challenge. Although there is a need to develop research issues that contribute significantly to a deeper understanding of the degree of environmental commitment of open pit mining lakes, the studies developed so far are few and have a predominantly Analytical Chemistry approach, an important approach, but that only offers momentary and limited answers. The main objective of this research was to analyze the environmental liabilities formed by waters and sediments of open pit mining lakes by application a combined method of environmental assessment based on Chemical, Ecotoxicological and Genotoxicological aspects. With this purpose, water samples were collected in profile and sediments from three lakes of deactivated open - pit gold mines existing in Mara Rosa, Goiás, Brazil, in different climatic seasons and subjected to metal and anion analysis, to ecotoxicological acute tests and genotoxicological tests- Comet assay - with the Danio rerio fish. The results showed different degrees of environmental commitment of the lakes, which present chemically altered waters and sediments, and offer toxicological risks, mainly the Lago Azul. This, being the most used by the local population for recreational purposes and water sports, proved to be subject to intense geological control from acid drainage processes. It is concluded that the environmental assessment methodology used in this thesis, in order to obtain broader and deeper responses to pit lakes, emerging environmental problems, was efficient, being able to constitute an analytical tool that will significantly contribute to the expansion of knowledge to the Environmental Sciences. / A indústria da mineração é conhecida por desencadear impactos ambientais intensos. Quando a exploração se dá a céu aberto, são formadas cavas, unidades ainda pouco conhecidas em termos ambientais e cada vez mais comuns em diversos países. De comportamento complexo, lagos de mineração se diferem muito dos naturais, o que torna sua gestão desafiadora. Embora exista a necessidade do desenvolvimento de questões de pesquisa que contribuam significativamente para um entendimento mais profundo a respeito do grau de comprometimento ambiental de cavas, os estudos desenvolvidos até então foram poucos e tiveram enfoque predominante na Química Analítica, abordagem importante, mas que obtém respostas momentâneas e limitadas. O objetivo principal desta pesquisa foi analisar os passivos ambientais formados por águas e sedimentos de cavas de mineração mediante a aplicação de uma metodologia combinada de avaliação ambiental embasada em aspectos da Química, Ecotoxicologia e Genotoxicologia. Para tanto, amostras de águas coletadas em perfil e de sedimentos de três cavas de ouro desativadas localizadas em Mara Rosa, Goiás, Brasil, foram obtidas em diferentes estações climáticas e submetidas à análise de metais e ânions e a testes ecotoxicológicos agudos e genotoxicológicos – Ensaio Cometa – com peixes da espécie Danio rerio. Os resultados indicam diferentes graus de comprometimento ambiental dos lagos, que apresentam águas e sedimentos alterados quimicamente e oferecem riscos toxicológicos, principalmente o Lago Azul. Este, apesar de ser o mais utilizado pela população local para fins de lazer e prática de esportes aquáticos, demonstrou estar submetido a intenso controle geológico advindo de processos de drenagem ácida. Concluiu-se que a metodologia de avaliação ambiental empregada nesta tese com a finalidade de obter respostas mais amplas e profundas a respeito de cavas, problemas ambientais emergentes, se mostrou eficiente, podendo se constituir em uma ferramenta analítica que contribuirá de forma significartiva para a ampliação do conhecimento na área das Ciências Ambientais.
133

Controle estatístico e previsão do monitoramento do índice de qualidade da água / Statistical control and monitoring of water quality index forecasting

Conceição, Ketllin Zanella da 12 June 2017 (has links)
Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2018-02-09T11:48:18Z No. of bitstreams: 2 Ketllin_Conceição2017.pdf: 1478973 bytes, checksum: a97631da6b15f46cfa48d39a4a2e9892 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-02-09T11:48:18Z (GMT). No. of bitstreams: 2 Ketllin_Conceição2017.pdf: 1478973 bytes, checksum: a97631da6b15f46cfa48d39a4a2e9892 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-06-12 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The unplanned development of large urban centers as well as the industrial one have hindered sustainable awareness regarding the correct water application. The unruly use of this resource has drawn the scientific community attention, thus, several scientific trials have been carried out in order to evaluate the use and quality of water. The use of indicators is one of the possibilities to evaluate water quality, which aims at analyzing physical-chemical and biological characteristics, and so allowing the evaluation of water body quality. In order to quickly evaluate the parameters involving water quality index (WQI), the process capability index was used. Thus, this trial aims at determining the water quality index as well as applying statistical quality control methodologies to evaluate the monitoring of water quality in rivers. Therefore, a database with physical-chemical and microbiological parameters from Passaúna and Piraquara rivers was applied to carry out this research development. Those rivers are in Araucária and Piraquara cities, respectively. The water quality index was determined by the time series, and subsequently data were submitted to statistical process control, with Shewhart individuals, EWMA and CUSUM, control charts as well as the development of the process quality index. Based on these data, a model of forecast was developed according to Holt-Winters Additive method. The WQI detected that the studied rivers remained under an averaged quality until the year of 2000, however, since that year, it was possible to observe a decreasing trend in water quality of the evaluated rivers. This trend was also identified by control charts. The graphs were also able to identify that waters of the rivers were not under statistical control, identifying some points that exceeded the used control limits. The process capacity index showed that the Piraquara River was classified with better quality of water when compared to the Passaúna River. The Holt-Winters prediction method showed that both rivers would continue with a decreasing trend in WQI and consequently in water quality. The applied statistical tools proved to be fast and efficient to evaluate water quality control. Finally, it is suggested that other researches should be developed using the technique of statistical process control for environmental evaluation. / O desenvolvimento desordenado dos grandes centros urbanos e o desenvolvimento industrial vêm dificultando a conscientização sobre o uso racional e sustentável da água. O uso indiscriminado desse recurso vem chamando atenção da comunidade científica e percebe-se uma infinidade de trabalhos científicos a fim de que se avaliem o uso e a qualidade da água. Uma das formas de se avaliar a qualidade da água é pela utilização de indicadores, que têm por finalidade analisar as características físico-químicas e biológicas e, assim, permitir a avaliação da qualidade das águas de um corpo hídrico. Utilizou-se o índice de capacidade do processo para se avaliar de forma rápida os parâmetros que envolvem o índice de qualidade da água (IQA). Desse modo, objetivou-se com esse trabalho determinar o índice de qualidade da água bem como aplicar metodologias de controle de qualidade estatístico para avaliar o monitoramento de qualidade da água em rios. Portanto, para se realizar o desenvolvimento da pesquisa, foi utilizado um banco de dados com parâmetros físico-químicos e microbiológicos dos rios Passaúna e Piraquara, pertencentes às cidades de Araucária e Piraquara, respectivamente. O índice de qualidade da água foi determinado com a série temporal e, posteriormente, esses dados foram submetidos ao controle estatístico do processo, com os gráficos de controle de Shewhart individual, MMEP e CUSUM, além do desenvolvimento do índice de qualidade do processo. A partir desses dados foi desenvolvido um modelo de previsão com o método de Holt-Winters Aditivo. O IQA detectou que os rios mantiveram-se em qualidade média até o ano 2000, entretanto, a partir desse ano foi possível visualizar uma tendência decrescente na qualidade das águas dos rios avaliados. Essa tendência também foi identificada pelos gráficos de controle. Os gráficos foram capazes de identificar que as águas dos rios não estavam em controle estatístico, identificando alguns pontos que excederam os limites de controle utilizados. O índice de capacidade do processo demonstrou que o rio Piraquara foi classificado com águas de melhor qualidade, quando comparado ao rio Passaúna. O método de previsão de Holt-Winters demonstrou que continuaria com uma tendência decrescente no IQA e, consequentemente, na qualidade da água, em ambos os rios avaliados. As ferramentas estatísticas utilizadas demonstraram ser rápidas e eficientes para a avaliação do controle de qualidade de águas. Por fim, sugere-se que sejam desenvolvidas mais pesquisas utilizando a técnica do controle estatístico do processo para avaliação do meio ambiente.
134

Qualidade do ar e suas implicações na saúde da comunidade de Vila Maranhão, São Luís (MA)

Viana, Marly Vieira 26 June 2015 (has links)
Made available in DSpace on 2016-08-19T17:47:08Z (GMT). No. of bitstreams: 1 Dissertacao-MarlyVieiraViana.pdf: 5588524 bytes, checksum: 88321b191df36a41b6c6b529d034366a (MD5) Previous issue date: 2015-06-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Air pollution has become a risk factor for human health, especially in the industrialized urban centers. Vila Maranhão neighborhood in São Luís (MA), because of its proximity to the industrial district, is more likely to be affected by air pollution. This paper analyzes the relationship between air quality and the prevalence of respiratory diseases for the residents of Vila Maranhão neighborhood. The study was descriptive and exploratory sectional with qualitative and quantitative approach. The sample was representative of 153 homes. We used questionnaire for analysis of socioeconomic conditions, health, environmental and health of residents. To survey the morbidity and mortality from respiratory diseases in the neighborhood, the data were used available from Secretaria de Saúde do Município (SEMUS) and through the database Sistema de Informação Hospitalar ( Hospital Information System) SIH / DATASUS, from 2006 to 2013. Data air quality were obtained from the monitoring station of Vale S / A, 2009- 2013.I thas been identified and located, the sources with atmospheric pollution potential and assessed the possible relationship between the emitted pollutants and health effects on residents. It was observed that the degree of correlation between deaths / admissions for respiratory diseases and concentration of air pollutants (particulate matter) were statistically very weak (r <0.04 and p <0.05). It was noticed also that the average annual hospitalizations / deaths from respiratory diseases to residents in Vila Maranhão neighborhood, in the period from 2006 to 2013, reached small indices in relation to the city of São Luís for the same period. With the initial data collected could not confirm a direct and unique relationship between injury due to respiratory diseases and air quality in the area. Secondary data monitoring air quality in the region may have contributed, as well as the underreporting of admissions, given that the studied population refers to the share of residents in Vila Maranhão treated SUS, getting unregistered served by the private sector health, those who do not seek medical care and the lack of pollutant dispersion study. But the study showed evidence of this relationship, with the need to conduct further studies on the subject. It should be evaluating the correlation with other aspects of which types of pollution sources, types of households, climatic elements, wind direction for a more detailed analysis of disorders and place of residence. / A poluição atmosférica tem se tornado um fator de risco para a saúde humana, especialmente nos centros urbanos industrializados. O bairro Vila Maranhão em São Luís (MA), por sua proximidade com o distrito industrial, tem maiores probabilidades de ser afetado pela poluição do ar. O presente trabalho analisa a relação entre qualidade do ar e a prevalência de agravos respiratórios para os moradores do bairro Vila Maranhão. O estudo foi seccional descritivo-exploratório com abordagem quali-quantitativa. A representação amostral foi de 153 domicílios. Utilizou-se questionário para análise das condições socioeconômicas, sanitárias, ambientais e de saúde dos moradores. Para o levantamento da morbimortalidade por Doenças do Aparelho Respiratório, foram utilizados os dados disponibilizados pela Secretaria de Saúde do Município (SEMUS) e através do banco de dados do Sistema de Informação Hospitalar SIH/DATASUS, dos anos de 2006 a 2013. Dados da qualidade do ar foram obtidos da estação de monitoramento da Vale S/A, de 2009 a 2013. Foram identificadas e localizadas, as fontes com potencial poluidor atmosférico e avaliado a possível relação entre os poluentes emitidos e efeitos na saúde dos moradores. Foi observado que os níveis de correlação entre óbitos/internações por doenças respiratórias e concentração de poluentes atmosféricos (material particulado) foram muito fracos estatisticamente (r<0,04 e p>0,05). Percebeu-se ainda, que a média anual de internações/óbitos por doenças respiratórias de residentes no bairro de Vila Maranhão, no período de 2006 a 2013, alcançou pequenos índices em relação à cidade de São Luís para o mesmo período. Com os dados iniciais levantados não foi possível confirmar uma relação direta e única entre os agravos por doenças respiratórias e a qualidade do ar na área. Os dados secundários de monitoramento da qualidade do ar da região podem ter contribuído, assim como as subnotificações das internações, haja vista a população estudada refere-se à parcela dos residentes na Vila Maranhão atendido pelo SUS, ficando sem registro os atendidos pelo setor privado da saúde, os que não procuram atendimento médico e a inexistência de estudo de dispersão de poluentes. Porém o estudo demonstrou indícios desta relação, havendo a necessidade de se realizar estudos mais aprofundados sobre o tema. Deve-se avaliar ainda a correlação com outros aspectos dentre os quais tipos de fontes poluidoras, tipo de domicílios, elementos climáticos e direção dos ventos, para uma análise mais detalhada dos agravos em saúde e local de residência.
135

Gas concentrations and emissions and nutrient flow in broiler houses with litter reuse / Concentrações de gases e emissões e fluxo de nutrientes em aviários de frangos de corte com cama reutilizada

Graciele Angnes 19 June 2017 (has links)
The commercial production of broiler chickens emits low amounts of nitrous oxide and methane, however, the production of CO2 and NH3 is considerable. Several countries have sought to investigate the emissions of greenhouse gases (GHG) and ammonia (NH3) in the production of broiler chickens since the information available in the literature is variable and uncertain. This is due to the diversity and particular conditions of the facilities, as well as the innumerable differences in the production system and the complex interactions observed in animal waste. Currently, gaseous pollutant measurements are costly techniques and difficult to put into practice in a large number of operations. The impacts of agriculture on global warming must be measured to allow Brazil to meet the commitments signed in COP-21 and to manage its production more precisely. In order to obtain reliable results, it is necessary to know the emission factors for the diverse production systems in the country. In view of this complexity, this research sought to apply a simplified sampling and emission determination technique that present low cost, simplicity, and robustness. The methodology uses the principle of concentration relations as a reference and determination of the concentration of gases was performed by INNOVA 1412. Weekly monitoring of concentrations of NH3, CO2, CH4, and N2O was conducted, considering the typical management of reused litter. The air quality was evaluated for the concentrations of NH3 and CO2, as recommended by international institutions. In addition, the thermal comfort of broiler house, considering the enthalpy index proposed in the literature and zootechnical performance, were measured. In order to identify the variables that best describe the emission flux of NH3 and CO2, mixed linear models with up to six variables were tested. N, C, and P balances were conducted for each production cycle in order to account for the inputs and outputs of the elements, as well as to verify the accuracy of the methodologies used. The main input of N, C, and P in the system was from reused litter, followed by the feed. The emissions allowed for the calculation of annual losses of 16 ± 4; 61 ± 16, and 168 ± 43 g of N2O, CH4, and NH3 bird-place-1 yr-1, respectively. Considering that this research presents an applicable and innovative methodology to determine GHG flows in broiler house for the country, the data will be useful for the Brazilian annual production of GHG emissions from poultry. The results are also useful to encourage new research that promotes knowledge of GHG emissions and alternatives to decrease emissions for meat production in Brazil. / A produção comercial de frangos de corte emite baixas quantidades de óxido nitroso e metano, no entanto, a produção de dióxido de carbono e amônia é considerável. Vários países têm buscado investigar as emissões de gases do efeito estufa (GEE) e amônia (NH3) na produção de frangos de corte já que as informações disponíveis na literatura são variáveis e incertas devido à diversidade das instalações, bem como das inúmeras diferenças no sistema de criação e das complexas interações observadas nos dejetos dos animais. Atualmente, a determinação das emissões gasosas exigem técnicas com custo elevado e difíceis de colocar em prática em um número elevado de instalações. Além disso, os impactos dos sistemas produtivos sobre o aquecimento climático devem ser medidos para permitir que o Brasil atenda os compromissos firmados na COP-21 e execute seu inventário de maneira mais precisa. A fim de obter resultados confiáveis é necessário conhecer os fatores de emissão na diversidade de sistemas de produção existentes no país. Diante dessa complexidade, nesta pesquisa buscou-se aplicar uma técnica simplificada de amostragem e determinação das emissões que apresenta baixo custo, simplicidade e robustez. A metodologia utiliza como referência, o princípio das relações de concentração e a concentração dos gases, que nesse casso foi determinada pelo INNOVA 1412. Buscou-se monitorar semanalmente as concentrações de NH3, CO2, CH4 e N2O considerando o manejo de reutilização da cama de frango. A qualidade do ar foi avaliada, considerando as concentrações de NH3 e CO2 recomendadas por instituições internacionais, assim como o conforto térmico dos aviários considerando os índices de entalpia propostos na literatura e o desempenho zootécnico. Determinou-se os fatores de emissão. E para identificar as variáveis que melhor descrevem o fluxo de emissão de NH3 e CO2, foram testados modelos lineares mistos com até seis variáveis. Balanços de N, C P foram conduzidos para cada ciclo de produção com a finalidade de contabilizar as entradas e saídas dos elementos e verificar a precisão das metodologias utilizadas. A principal entrada de N e C no sistema foi pela reutilização da cama, seguida pela ração. As emissões permitiram calcular perdas anuais de 16 ± 4; 61 ± 16; e 168 ± 43 g de N2O, CH4 e NH3 ave-alojada-1 ano-1, respectivamente. Considerando que esta pesquisa apresenta uma metodologia aplicável e de baixo custo para determinar as emissões de GEE em aviários de frangos de corte no Brasil, os resultados são úteis para incentivar novas pesquisas que possam avançar no conhecimento das emissões e possíveis técnicas de mitigação de GEE na produção de frangos de corte no Brasil.
136

Avaliação da qualidade sanitária da água do Rio Uno e período de chuva

Aline Briet de Almeida Silva 07 December 2007 (has links)
Este estudo teve por finalidade buscar informações sobre a qualidade da água do rio Una, por meio de análises de coliformes totais e coliformes termotolerantes, bem como de estudos sobre os impactos causados no entorno. Foram coletadas oito amostras ao longo do Rio Una. As taxas de coliformes totais foram de 1000 e &#8805; 1600 NMP/mL, nos meses de dezembro de 2006, janeiro e março de 2007, enquanto nos meses de fevereiro e abril os resultados variaram de 17 a 300 por 100 mL. Os coliformes termotolerantes nos meses de dezembro de 2006, janeiro e março de 2007 em alguns pontos de coleta apresentaram-se fora do valor permitido para rio pertencente à classe 2. Desta forma, pode-se concluir que esses valores de coliformes evidenciam que o foco de contaminação é de despejos de esgotos "in natura" e a animais que ficam na margem do rio. A má ocupação do espaço vem causando sérios danos à conservação dos recursos hídricos. / The aim of this work is to determine the water quality of Rio Una, through analysis of total coliforms and thermotolerants coliform as well as studies on the environmental impacts. Eight samples were collected along the Rio Una. The rates of total coliforms were 1000 and &#8805; 1600 MPN/100 mL, in the December 2006, January and March 2007, while in February and April results varied from 17 to 300/100 mL. Thermotolerants coliforms in December 2006, January and March 2007, in some points of collection had been out of the amount allowed for to the class 2 river. Thus, it was concluded that these values of coliforms show that the focus of contamination from sewage waste is "in natura" and to animals that are around the river. The bad occupation of the area has caused serious damage to the conservation of water resources.
137

Qualidade do ar interno com ênfase na concentração de aerodispersóides nos edifícios. / The indoor air quality in the buildings with an emphasis on the concentration of particulates matters.

Moraes, Alexandre Perri de 28 June 2006 (has links)
No presente trabalho, é avaliada a qualidade do ar interno com ênfase na concentração de aerodispersóides presentes em edifícios comerciais e residenciais com sistema de ventilação natural ou condicionamento de ar. De fato, algumas doenças de origem ocupacional são causadas pela inalação de aerodispersóides nocivos à saúde. O método utilizado para avaliar a qualidade do ar interno nos edifícios comerciais e residenciais consistiu primeiramente em caracterizar os medidores de aerodispersóides e em seguida passou-se para a análise das concentrações e das características ambientais. A pesquisa mediu a concentração de aerodispersóides em edifícios com sistemas de ventilação diferentes (1a fase), e identificou as principais fontes de emissão de aerodispersóides em um apartamento residencial (2a fase). Observou-se que as concentrações obtidas na pesquisa estão acima dos valores recomendados na RE n° 9 (ANVISA, 2003) e por Morawska et al. (1999) que atribuem valores de 80 µg/m³ e 7.400 part./cm³, para concentrações médias em massa e em número, respectivamente. Com base nas observações acima, chegou à conclusão que as concentrações médias em massa e em número de aerodispersóides, durante as atividades domésticas (cozimento, reforma, limpeza, entre outras), foram várias vezes maiores do que as concentrações obtidas em ambientes com atividades profissionais ou com menor ocupação durante o dia. / This paper is the result of quality evaluation of indoor air quality with emphasis on the concentration of aerodispersoid in commercial and residential buildings with natural ventilation or air conditioning systems. In fact, some of the occupational diseases are caused by the inhalation of aerodispersoids hazardous to health. The method applied to evaluate the indoor air quality in commercial and residential buildings consisted firstly of characterizing the aerodispersoid measuring devices and subsequently analyzing the concentration levels and environmental characteristics. This research measured the concentration of aerodispersoids in buildings equipped with a variety of ventilation systems (phase1) and next it identified the main emission sources in a residential apartment (phase 2). It was observed that the concentration levels measured were above the specifications recommended by RE n° 9 (ANVISA, 2003) and by Morawska et al. (1999) which attribute values of 80 µg/m³ and 7.400 part./cm³, for average concentration in mass and number respectively. Based on the above information it was concluded that the average concentration levels of aerodispersoids in mass and number in home related activities (cooking, restoration, cleaning, etc) were many times higher than the concentration levels found in business environments or in environments with less occupation during the day.
138

Particulate matter inside residences of elderly in the Metropolitan Area of São Paulo / Material particulado em residências de idosos na Região Metropolitana de São Paulo.

Segalin, Bruna 24 November 2017 (has links)
The elderly population is sensitive to damages caused by air pollution on health. They spend relatively more time indoors, however there is limited information on the air quality they breathe inside their residences. The objectives of this work are to characterise mass of sizesegregated particulate matter (PM) in elderly residences in Metropolitan Area of Sao Paulo (MASP) in Brazil; assess the meteorological parameters influence; evaluate the indoor and outdoor relationship of PM; quantify the ions, trace elements and black carbon (rBC) in quasi-ultrafine particles (qUFP) and identify their sources, and estimate the respiratory deposition doses (RDD). To achieve these objectives, we measured during 24 hours the mass concentrations of PM in differents sizes (102.5, 2.51.0, 1.00.5, 0.50.25 and <0.25 µm (PM0.25, qUFP) in 59 elderly residences in MASP using a Personal Cascade Impactor Sampler. The PM10 is the sum of all size and PM2.5 is PM10 less PM102.5. The PM2.5 and PM0.25 contributed 78% and 38% of total PM10, respectively. About 77% and 40% of the residences had higher PM2.5 and PM10 than those in outdoor environments. About 13 and 43% of the measurements exceeded the World Health Organization (WHO) guidelines for PM10 and PM2.5, respectively. The PM0.25 exceeded the WHO guideline for PM2.5 in 8.3% of residences. Residences with higher PM concentration in all size bins are predominantly near the heavy traffic areas during the nonprecipitation days. About 68% of residences have the highest mass concentration in PM0.25. We analysed ions by chromatography, trace elements by x-ray fluorescence and rBC by reflectance. The major of ions concentrations in qUFP were found to be SO42- and NH4+, and the major trace elements were Si and Fe. Around 26% of the qUFP is rBC. Some residences have a high concentration of the toxic heavy metals Cu, Ni, Pb and Cr. We identified 6 dominant sources of the indoor qUFP by positive matrix factorization: vehicular emission (57%), secondary inorganic aerosol (21%), soil and construction (7%), wall painting (7%), cooking (5%) and industry (3%). The RDD for coarse and fine particles were found to be 20% and 24.6% higher for male than female elderly during seated position, respectively. The maximum RDD of qUFP and rBC are in the tracheobronchial part. It is important the control of PM sources in the elderly residences to limit adverse health effects of PM, especially fine particles. We suggest consider the rBC as one regulated air pollutant in terms of public control actions for air quality improvement in MASP. / A população idosa é sensível aos riscos da poluição do ar à saúde. Os idosos passam mais tempo dentro de suas casas, mas há pouca informação sobre a qualidade do ar dentro de suas residências. Os objetivos deste trabalho são caracterizar a massa do material particulado (PM) de diferentes tamanhos em residências de idosos na Região Metropolitana de São Paulo (RMSP) no Brasil; avaliar a influência dos parâmetros meteorológicos e a relação entre PM de ambiente interno e externo; quantificar os íons, elementos traços e black carbon (rBC) em partículas quasi-ultrafinas (qUFP) e identificar suas fontes, e estimar as doses de deposição de PM no trato respiratório (RDD). Para alcançar esses objetivos, medimos durante 24 horas as concentrações em massa de PM nos tamanhos 10-2,5; 2,5-1,0; 1,0-0,5; 0,5-0,25 e <0,25 m (PM0.25, qUFP) em 59 residências de idosos na RMSP usando o Personal Cascade Impactor Sampler. O PM10 é a soma da massa em todos os tamanhos e PM2.5 é o PM10 menos o PM10-2.5. O PM2.5 e PM0.25 contribuíram com 78% e 38% do total de PM10, respectivamente. Cerca de 77% e 40% das residências apresentaram maior concentração de PM2.5 e PM10 do que aqueles em ambientes externos. Cerca de 13 e 43% das medidas excederam as diretrizes da Organização Mundial de Saúde (OMS) para PM10 e PM2.5, respectivamente. O PM0.25 excedeu o limiar da OMS para PM2.5 em 8.3% das residências. As residências com maior concentração de PM em todos os tamanhos estão próximas das áreas de intenso tráfego veicular e não houve precipitação durante a medição. Cerca de 68% das residências têm a maior concentração de massa em PM0.25. Analisamos os íons por cromatografia, elementos traços por fluorescência de raios-x e rBC por reflectância. A maior concentração de íons em qUFP foi SO42- e NH4+, e os principais elementos traços foram Si e Fe. Cerca de 26% do qUFP é rBC. Algumas residências têm uma alta concentração dos metais pesados tóxicos Cu, Ni, Pb e Cr. Identificou-se 6 fontes de qUFP por fatoração de matriz positiva: emissão de veículos (57%), aerossol inorgânico secundário (21%), solo e construção (7%), pintura de parede (7%), cozimento (5%) e indústria (3%). O RDD para PM10-2.5 e PM2.5 foi 20% e 24,6% maior para homens do que mulheres enquanto sentados, respectivamente. O RDD máximo de qUFP e rBC foi na parte traqueobrônquica. É importante o controle de fontes de PM nas residências de idosos para limitar os efeitos adversos à saúde, especialmente partículas finas. Sugerimos considerar o rBC como um poluente atmosférico regulado em termos de ações de controle público para a melhoria da qualidade do ar na RMSP.
139

Estudo de eficiência da ventilação em sistema de climatização com distribuição de ar pelo piso. / Ventilation effectiveness study of an underfloor air distribution system.

Marè, Renata Maria 21 May 2010 (has links)
A aplicação de sistemas de climatização com distribuição de ar pelo piso tem aumentado em países desenvolvidos, o que também tem ocorrido no Brasil. Em paralelo, tem crescido o interesse pela qualidade do ar interior e os seus efeitos no bem estar, saúde e produtividade dos ocupantes de uma edificação. Diversos estudos têm apontado para as vantagens deste sistema em relação à remoção de contaminantes do ambiente interior. Este sistema tem figurado nos programas de certificação ambiental de edificações como uma alternativa vantajosa para a melhoria da qualidade do ar interior e o conforto térmico com preservação da eficiência energética, recebendo pontuação adicional. Com o crescente interesse por este tipo de sistema, estudos que aprimorem o seu projeto visando à melhor eficiência global mostram-se essenciais. Este estudo tem como principal objetivo verificar experimentalmente a contribuição de um sistema de climatização com distribuição de ar pelo piso para a qualidade do ar interior de um ambiente, sendo este uma sala de aula para 48 alunos situada no Departamento de Engenharia de Construção Civil da Escola Politécnica da Universidade de São Paulo, em condições reais de uso. Para isso, foram medidas as concentrações de partículas em suspensão na zona de respiração para pessoas sentadas (a 1,10 m do piso), e no retorno do ar (a 2,60 m do piso) simultaneamente, sob seis diferentes valores de temperatura do ar na zona ocupada (a 0,60 m do piso), previamente escolhidos. Estas concentrações permitiram o cálculo e a análise do índice de efetividade na remoção de contaminantes IERC no ambiente, para partículas e CO2 (segunda etapa das medições). Simultaneamente, foram realizadas medições de variáveis de conforto térmico no ambiente, temperatura do ar e velocidade do ar, em seis diferentes alturas e quatorze pontos do ambiente. As baixas concentrações de partículas em suspensão (inferiores a 0,035 mg/m³) mostraram que este sistema não dispersa contaminantes no ar interior. Os IERC próximos ou superiores à unidade em todas as condições de operação do sistema, tanto para partículas em suspensão como para CO2, comprovaram a sua eficiência na remoção de contaminantes do ambiente interior. / The use of underfloor air distribution (UFAD) systems is growing in developed countries, and this is also observed in Brazil. Besides, the interest in indoor air quality and its effects on the well being, health and productivity of the occupants in a building is an important issue nowadays. Many studies have related the advantages of UFAD systems in removing indoor air contaminants from the ambient as compared to overhead systems. In the building certification systems, they figure as good alternatives to promote better indoor air quality and thermal comfort, preserving energy efficiency, which corresponds to additional points. With the expanding interest in this technology, studies that enhance its project, keeping as a goal its global efficiency, are very welcome. The aim is to experimentally verify the contribution of an UFAD system to the indoor air quality of a classroom used by 48 students at the Civil Construction Department of the Engineering School of the University of São Paulo Brazil. The study has been conducted in a non-steady state condition. In order to perform this evaluation, the levels of indoor air-borne particles were measured at the breathing zone for seated people (1.10m from the ground), and at the exhaust (2.60m from the ground) simultaneously, under six different pre-defined values of air temperature at the occupied zone (0.60m from the ground). These concentration levels have allowed calculating the contaminant removal effectiveness index, CRE, in many points of the ambient. A similar analysis was developed for the concentrations of CO2 in the second part of the experiment. At the same time, the air temperature and air velocity were measured in six different levels and at fourteen points of the ambient. The low concentration levels of total suspension particle (under 0.035 mg/m³) have shown that this system doesn\'t disperse air contaminants indoors. The CRE indexes near or above 1.0, for both total suspension particle and CO2, have confirmed the ventilation effectiveness of this underfloor air distribution system under all the operational conditions.
140

Qualidade da ?gua de rios e sistemas de esgotamento sanit?rio

Pessoa, Jonatan Onis 19 July 2016 (has links)
Submitted by Ricardo Cedraz Duque Moliterno (ricardo.moliterno@uefs.br) on 2017-02-02T01:06:32Z No. of bitstreams: 1 disserta??o_Jonatan_Onis_Pessoa.pdf: 4697484 bytes, checksum: ea38c6fd7eba2bd885530337c94efbff (MD5) / Made available in DSpace on 2017-02-02T01:06:32Z (GMT). No. of bitstreams: 1 disserta??o_Jonatan_Onis_Pessoa.pdf: 4697484 bytes, checksum: ea38c6fd7eba2bd885530337c94efbff (MD5) Previous issue date: 2016-07-19 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / Sewage systems when properly operated can help to minimize of aquatic environments degradation. In this context, this study aimed to evaluate the river water quality in towns with and without sewage. Therefore, ten towns of Bahia State were selected, seven of them containing sewage and three devoid of such services. It was used secondary data from water river quality (INEMA ? Environmental Stare Agency), sewage (SNIS). Parameters analyzed were concentration of fecal coliforms, biochemical oxygen demand, total phosphorus, dissolved oxygen and the Water Quality Index - IQA 14 points monitored in the period 2008 to 2015. Data were submitted the statistical analysis using the Kruskal-Wallis test. It was found that average AQI values ranged from 26 to 72. The four points monitored in towns without public sewage system presented classified waters as "good" while 40% of monitored points in cities with SES have waters classified as "regular 'or' bad '. Results suggest that the release of sewage into storm water systems and receiving bodies seems to be the main cause of low AQI values. Thus, there has been the weakness of the towns as the supervision of illegal sewage connections. Environmental education campaigns are recommended in order to reduce such practices and to improve water quality in rivers in these towns. / Os sistemas de esgotamento sanit?rio (SES), quando bem operados, s?o interven??es que podem contribuir para a minimiza??o da degrada??o de ambientes aqu?ticos. Nesse contexto, o presente trabalho teve como principal objetivo avaliar a qualidade da ?gua de rios em cidades com sistema p?blico de esgotamento sanit?rio implantado. Para tanto, foram selecionadas dez cidades do Estado da Bahia, sendo sete delas contendo SES e tr?s sem tais servi?os. Utilizou-se o registro trimestral realizado pelo INEMA da concentra??o de coliformes termotolerantes, demanda bioqu?mica de oxig?nio, f?sforo total, oxig?nio dissolvido e o ?ndice de Qualidade da ?gua - IQA de 14 pontos monitorados no per?odo compreendido entre 2008 a 2015. Os dados foram submetidos ? an?lise estat?stica, utilizando o teste de Kruskall-Wallis. Verificou-se que valores m?dios de IQA variaram entre 26 a 72. Os quatro pontos monitorados nas cidades sem sistema p?blico de esgotamento sanit?rio apresentaram ?guas classificadas como ?boa? ao passo que 40% dos pontos monitorados nas cidades com SES tiverem ?guas classificadas como ?regular? ou ?ruim?. Os resultados encontrados sugerem que o lan?amento de esgotos nos sistemas de ?guas pluviais e nos corpos receptores parece ser a principal causa dos baixos valores de IQA. Dessa forma, constata-se a fragilidade das cidades quanto ? fiscaliza??o de liga??es irregulares de esgoto. Campanhas de educa??o ambiental s?o recomendadas visando a redu??o de tais pr?ticas e a melhoraria da qualidade da ?gua nos rios das cidades avaliadas.

Page generated in 0.0756 seconds