Avaliação da qualidade do ar em ambientes internos: biblioteca pública / Indoor air quality investigation: public library

Guilherme Caetano do Nascimento 01 April 2011 (has links)
Ao longo de quinze meses, foram monitorados na Biblioteca Pública Amadeu Amaral, da cidade de São Carlos, SP, os níveis de temperatura, umidade relativa, ruído, intensidade luminosa, contaminação por dióxido de carbono, material particulado total (MPT) e suas frações respiráveis (MP1, MP2,5, MP7 e MP10), avaliação da taxa de ventilação e ocupação, concentração de bioaerossóis e sua identificação. Além disso, foi aplicado um questionário aos ocupantes do local com o intuito de levantar as principais reclamações e queixas relacionadas à qualidade do ar interior. Os resultados mostraram o desconforto térmico do local em todas as salas monitoradas, altos níveis de ruído proveniente do ambiente externo, inadequações relativas à iluminação do local e necessidade de uma atenção especial à taxa de ocupação do prédio. Durante alguns momentos das medições, os níveis de ruído ultrapassaram a barreira dos 80 dB(A), que é um valor bem acima do recomendado em normas, revelando-se um fator de risco para seus usuários e funcionários. Não foram encontrados problemas relacionados à contaminação biológica do local, analisando a concentração de bactérias e fungos. A taxa de ventilação possui valor adequado para o piso 1 e a concentração de gás carbônico se manteve de acordo com os padrões estabelecidos em normas. As respostas dos questionários confirmam os principais resultados encontrados para a Biblioteca, como os altos níveis de ruído, o desconforto térmico do local e as inadequações da iluminação. As recomendações são pautadas na necessidade de realização de ensaios gravimétricos da concentração de material particulado e o desenvolvimento de estudos específicos para a adoção de medidas mitigadores da poluição sonora e, também, da adequação das salas para o conforto térmico dos ocupantes. / Over fifteen months, levels of temperature, humidity, noise, light intensity, contamination by carbon dioxide, total suspended particles (TSP) and respirable fractions (PM1, PM2.5, PM7 and PM10) were monitored at the Public Library Amadeu Amaral at São Carlos, SP. Investigation of the ventilation rate and occupancy, concentration of bioaerosols and identification were also performed. In addition, a questionnaire was handed over to the occupants of the site in order to raise the main complaints related to indoor air quality. The results showed the discomfort of the place at all rooms monitored, high levels of noise from the outside environment, inadequacies relating to the site illumination and special attention to the building occupancy. During some measurements, the noise levels exceeded the barrier of 80 dB (A), which is above the recommended standards and proved to be a risk factor for its users and employees. No problems were found related to the site biological contamination, analyzing the concentration of bacteria and fungi. The ventilation rate has adequate value to the first floor and carbon dioxide concentration was maintained in accordance with the standards. The questionnaire responses confirm the main findings to the library, such as high noise levels, thermal discomfort and the illumination problem. The main recommendations are based on the need of gravimetric particulate matter investigation and development of specific studies for the adoption of mitigation measures on noise pollution and also the suitability of the rooms to the thermal comfort of occupants.
112

[en] AIR QUALITY MONITORING IN THE STATE OF RIO DE JANEIRO, BRAZIL, THROUGH POLLUTION AND ECOTOXICOLOGICAL BIOMONITORING ASSESSMENTS / [pt] MONITORAMENTO DA QUALIDADE DO AR NO ESTADO DO RIO DE JANEIRO, BRASIL, ATRAVÉS DA AVALIAÇÃO DA POLUIÇÃO E DO BIOMONITORAMENTO ECOTOXICOLÓGICO

KARMEL BERINGUI DE OLIVEIRA DA SILVA 28 June 2022 (has links)
[pt] O intenso crescimento dos centros urbanos provocou aumento considerável da emissão de poluentes atmosféricos, conferindo destaque à poluição atmosférica. A qualidade do ar de uma determinada região pode ser afetada por fatores como tipos e quantidades de fontes de emissão, meteorologia e topografia, o que confere complexidade para essa área de estudo. Os principais poluentes legislados no Brasil são SO2, NO2, CO, O3 e o material particulado (MP). Dentre esses, o MP pode ser considerado como uma das mais importantes classes de poluentes devido sua composição heterogênea, que pode causar efeitos adversos à saúde e ao meio ambiente. O monitoramento dos poluentes atmosféricos para fins de fiscalização pode ser realizado utilizando métodos padronizados que incluem equipamentos capazes de determinar a concentração dos poluentes em tempo real. No Rio de Janeiro, as principais redes de monitoramento da qualidade do ar pertencem ao Instituto Estadual do Meio Ambiente (INEA) e à prefeitura do Rio de Janeiro, que dispõem de estações automáticas em diversas regiões da cidade e do estado. Entretanto, o monitoramento tradicional da poluição atmosférica demanda altos investimentos para compra e manutenção desses equipamentos, diminuindo as áreas passíveis de monitoramento. O biomonitoramento, por sua vez, que utiliza organismos vivos para avaliar mudanças ambientais, é considerado uma abordagem adequada para ampliar as áreas monitoradas e avaliar os impactos causados pela poluição. Assim, o objetivo deste estudo foi avaliar a qualidade do ar no Rio de Janeiro através do biomonitoramento ativo utilizando Tillandsia usneoides e Tillandsia stricta como biomonitores, investigando o estresse oxidativo causado pela exposição aos metais. Considerando o efeito das fontes de emissão na qualidade do ar, buscou-se também avaliar a qualidade do ar no Rio de Janeiro durante os primeiros meses da pandemia de COVID-19, quando a mobilidade urbana foi alterada consideravelmente. Nessa avaliação foi considerada ainda a influência das condições meteorológicas por meio da comparação com dados obtidos para os mesmos períodos do ano anterior. O biomonitoramento ativo foi realizado entre julho de 2019 e novembro de 2020 em cinco locais do Rio de Janeiro com diferentes características quanto a emissão de poluentes: Ramos, Urca, Niterói, Duque de Caxias e Santa Cruz. As plantas foram removidas de um local rural e instaladas nos locais de monitoramento em julho de 2019 e coletadas em outubro de 2019, janeiro e novembro de 2020. A avaliação do estresse oxidativo foi realizada através da quantificação dos biomarcadores Metalotioneína (MT), Glutationa Reduzida (GSH), H2O2 e Peroxidação Lipídica, medida pela concentração de malondialdeído (MDA). Para avaliar a fração biodisponível dos metais presente no tecido das plantas foi realizada distribuição subcelular através do procedimento de purificação da metalotioneína, que fornece três frações nas quais os elementos foram quantificados por espectrometria de massas com plasma indutivamente acoplado (ICP-MS), bem como a quantificação dos metais totais realizada em extratos ácidos dos tecidos das plantas. Na avaliação da qualidade do ar durante a pandemia, os dados de concentração de NO2, SO2, CO e O3 e variáveis meteorológicas foram fornecidos pelo INEA para março e abril de 2020 e usados para avaliar mudanças na qualidade do ar em comparação com o ano anterior e a contribuição das condições meteorológicas. A prefeitura do Rio de Janeiro forneceu dados de CO, O3 e PM10 e variáveis meteorológicas para o período entre março e setembro que foram usados para uma avaliação que considerou o impacto das medidas de distanciamento social na qualidade do ar através do acompanhamento desde o primeiro decreto de restrição até a abertura econômica total. Nos dois casos, os dados foram submetidos a destes estatísticos e análises temporais. O biomonitoramento da qualidade do ar indicou que os principais elementos encontrados nos biomonitores foram Fe, Na, K, Ca, Mg and Al. Elementos relacionados ao tráfego veicular, como Pb, Cr, Cu and V também foram encontrados em concentrações expressivas. A T. usneoides apresentou maiores concentrações em comparação com a T. stricta, entretanto, o enriquecimento das duas espécies em relação à amostra de referência foi similar, indicando que ambas são adequadas para o biomonitoramento. Duque de Caxias e Santa Cruz apresentaram os maiores enriquecimentos, o que pode estar relacionado com a contribuição das emissões industriais. A avaliação da distribuição subcelular dos metais demonstrou que Cr, Co, Cu, Cd, Mn, Ni, Se and Zn foram encontrados na fração termoestável da purificação da metalotioneína, o que indica que as plantas estão em processo de destoxificação desses elementos. A T. stricta apresentou maiores percentuais da fração não biodisponível, o que indica que essa espécie é mais resistente aos efeitos tóxicos causados pelos metais. Foi observado ainda que em períodos secos a absorção das plantas é menor, devido ao metabolismo ácido das crassuláceas (CAM), que favorece o controle hídrico em condições de baixa umidade mantendo as organelas responsáveis pelas trocas gasosas fechadas durante o dia, período no qual se registram maiores concentrações de poluentes. Os biomarcadores de estresse oxidativo indicaram que as duas espécies estão em condições semelhantes de estresse oxidativo, pois suas concentrações não apresentaram diferença significativa entre as espécies na maioria dos casos. As correlações entre os biomarcadores indicaram que a principal função da GSH é no sistema antioxidante, embora em alguns caso ela tenha atuado auxiliando a MT na destoxificação de metais. As correlações de H2O2 com MT e GSH indicam que a exposição de metais estimula e produção de espécies reativas de oxigênio (ROS), como H2O2, cuja concentração pode ser regulada pela ação da GSH, entretanto, a correlação com MDA indica que o sistema antioxidante não está sendo eficiente na prevenção do estresse oxidativo. A avaliação da qualidade do ar durante a pandemia revelou que a redução de até 85 por cento na mobilidade urbana foi a principal responsável pela melhora da qualidade do ar, principalmente nos primeiros meses de isolamento social. Foi registrada diminuição na concentração dos poluentes primários e aumento da concentração de O3, um poluente secundário. Esse mesmo comportamento também foi registrado em outras cidades ao redor do mundo e é atribuído aos complexos processos de formação de ozônio, que dependem da concentração de alguns poluentes primários. Embora as concentrações de ozônio tenham aumentando, o índice de qualidade do ar durante a pandemia foi melhor do que em períodos com a rotina normal das cidades. A contribuição das condições meteorológicas não apresentou muita influência, uma vez que se mostrou semelhante ao mesmo período do ano anterior. A avaliação da qualidade do ar no Rio de Janeiro revelou que as emissões veiculares são as principais fontes de poluentes atmosféricos, e que a mudança no fluxo de veículos pode melhorar a qualidade do ar, embora empreendimentos industriais também apresentem expressiva contribuição. A poluição urbana pode causar desequilíbrio ambiental, uma vez que a vegetação está em constante exposição. Podese destacar ainda que o estado do Rio de Janeiro abriga importantes remanescentes de mata atlântica, o que demanda constante fiscalização visando a garantia da preservação ambiental. / [en] The intense growth of urban centers has caused a considerable increase in atmospheric pollutant emission, which can lead to human health and ecosystem risks. The air quality monitoring network in Brazil is limited, covering not even half of the states. Biomonitoring employing plants is, thus, an alternative to increase the monitored areas and still allow the ecotoxicological evaluations concerning air pollution exposure. In this sense, this study sought to evaluate the air quality of the metropolitan region of Rio de Janeiro using official atmospheric pollutant concentration data and biomonitoring efforts aiming to investigate oxidative stress in the bromeliad species used as biomonitors. During the social isolation period established as a contingency measure against the spread of the coronavirus, air quality was improved overall, although ozone concentrations increased relative to the previous year and the period preceding the lockdown. This change was attributed to an urban mobility reduction of up to 85 percent. The biomonitoring assessments indicate that the main elements taken up by the plants were those related to vehicular traffic. The correlation of these elements with oxidative stress biomarkers indicate that air pollution exposure represents a risk to local ecosystems. Tillandsia stricta and Tillandsia usneoides displayed similar behavior regarding metal accumulation, albeit presenting different detoxification processes. Although Rio de Janeiro has one of the most widespread air quality monitoring networks, studies aimed to assess the environmental air pollution impacts are required, considering that the state is home to important and endangered Atlantic Forest remnants. In additions, vehicular emission control can contribute to air pollution reduction, considering that this is one of the main pollutant sources.
113

[en] ASSESSMENT OF THE INFLUENCE OF VEHICULAR TRAFFICON AIR POLUTION IN DIFFERENT LOCATIONS IN THE METROPOLITAN REGION OF RIO DE JANEIRO / [pt] AVALIAÇÃO DA INFLUÊNCIA DO TRÁFEGO VEICULAR SOBRE A POLUIÇÃO DO AR EM DIFERENTES LOCAIS DA REGIÃO METROPOLITANA DO RIO DE JANEIRO

ALLAN VINICIUS ALMEIDA DO AMARAL 26 April 2022 (has links)
[pt] Neste trabalho foi feita a quantificação e a caracterização química de material particulado (PM, do inglês particulate matter), com foco no material particulado grosso (PM10) coletado em quatro diferentes locais da região metropolitana do Rio de Janeiro (Gericinó, Zona Oeste; Duque de Caxias, Baixada Fluminense; Bonsucesso, Zona Norte e Centro- região central da cidade), utilizando amostradores de grande volume e filtros de fibra de vidro fornecidos pelo Instituto Estadual do Ambiente (INEA). Utilizando filtros ao longo do ano de 2019, foram feitas análises em Cromatógrafo de íons (CI) e espectrometria de massas com plasma indutivamente acoplado (ICP-MS) para a caracterização das amostras e quantificação de íons e metais. Também foi feita avaliação de concentração de PM10 sob influência da precipitação ao longo de 10 anos de estudo (2010 a 2019) e os níveis comparados com os valores recomendados pelo CONAMA. Para complementar o estudo foi realizado um levantamento bibliográfico sobre poluição veicular relacionada ao PM10 no Brasil. Os resultados apontam para um aumento nos níveis de PM10 ao longo da década avaliada, principalmente na região de Bonsucesso, com concentrações médias de 62 (micro)g m-3 , em alguns casos ultrapassando os limites do CONAMA. Com relação á precipitação, houve diferença significativa estatisticamente em dias sob ocorrência de chuva e dias sob ausência de chuva. Os íons que apresentaram as maiores concentrações foram NO3 - , SO4 2- e Na+ com concentrações médias variando de 2,6-3,4; 3,0- 3,3; 2,4- 3,0 (micro)g m-3, respectivamente, em todas as estações do estudo. A análise dos metais definiu Fe e Cu como os metais em maior concentração nas amostras, com concentrações médias variando de 0,54 a 0,73 e de 0,023 a 0,047 (micro)g m-3 , respectivamente. Tais resultados são reforçados pela análise de Black carbon através de absorção ótica, que reportou uma concentração média variando de 3,6 a 6,0 (micro)g m-3 . A região de Bonsucesso revelou ser a que apresentou as maiores concentrações para os parâmetros supracitados, confirmando a influência do maior tráfego veicular reportado para a região. / [en] In this work, the quantification and chemical characterization of particulate matter (PM) was carried out, focusing on coarse particulate matter (PM10) collected in four different locations in the metropolitan region of Rio de Janeiro (Gericinó, West Zone; Duque de Caxias, Baixada Fluminense; Bonsucesso, North Zone and Center-central region of the city), employing large volume samplers and fiberglass filters, supplied by the State Institute of the Environment (INEA). Using filters throughout 2019, analyzes were carried out in Ion Chromatograph (IC) and inductively coupled plasma mass spectrometry (ICP-MS) for the characterization of the samples and quantification of ions and metals. An evaluation of PM10 concentration under the precipitation influence was also carried out over 10 years of study (2010 to 2019) and the levels compared with the values recommended by CONAMA. To complete the study, a bibliographic study on vehicular pollution related to PM10 in Brazil was implemented. The results point to an increase in PM10 levels over the evaluated decade, mainly in the Bonsucesso region, with average concentrations of 62 (micro)g m-3 , in some cases overreaching the limits of CONAMA. Concerning the precipitation, there was a statistically significant discrepancy in days with rain and days without rain. The ions that showed the highest concentrations were NO3 - , SO4 2- and Na+ with mean concentrations ranging from 2.6-3.4; 3.0-3.3; 2.4-3.0 (micro)g m-3 , respectively, in all groups of the study. The metal analysis defined Fe and Cu as the most represented metals in the samples, with mean concentrations ranging from 0.54 to 0.73 and from 0.023 to 0.047 (micro)g m3 , respectively. Such results are strengthened by the analysis of Black carbon through optical absorption, which reported an average concentration ranging from 3.6 to 6.0 (micro)g m-3 . The Bonsucesso region showed to be the one with the highest concentrations for the aforementioned parameters, confirming the influence of the greater vehicular traffic reported for the region.
114

[pt] AVALIAÇÃO DA QUALIDADE DO AR NA RODOVIA RIO-PETRÓPOLIS (BR-040), CONSIDERANDO OS CENÁRIOS DE ROTINA E INTERVENÇÕES POR OBRAS / [en] EVALUATION OF AIR QUALITY IN THE RIO-PETRÓPOLIS HIGHWAY (BR040), CONSIDERING THE ROUTINE SCENARIOS AND INTERVENTIONS BY ROAD CONSTRUCTION

KARMEL BERINGUI DE OLIVEIRA DA SILVA 14 April 2020 (has links)
[pt] Este estudo pretende avaliar as influências do tráfego de rotina e da construção de um novo trecho da BR-040, entre Duque de Caxias e Petrópolis, na emissão e composição do material particulado (MP) da região. As obras foram iniciadas em 2014 e interrompidas em junho de 2016. Foram realizados o monitoramento tradicional de MP e biomonitoramento com Tillandsia usneoides e Tillandsia stricta transplantadas em seis locais de amostragem ao longo da rodovia. O Laboratório de Estudos de Poluição Atmosférica (LEPA) forneceu filtros contendo partículas totais em suspensão (PTS), coletadas entre 2014 e 2016. A espectrometria de massas com plasma indutivamente acoplado (ICP-MS) e a cromatografia iônica (CI) foram utilizadas para a caracterização química das PTS. Em 2014 foram observadas as maiores concentrações médias de PTS nos pontos próximos ao pedágio. Em 2016 não houve diferença nas concentrações de PTS entre períodos com obras e em sua ausência. O elemento majoritário nas PTS foi Fe e os maiores fatores de enriquecimento (FE) foram obtidos para Cu, Cd e Ni. Os íons em maior concentração foram NO3-e SO4-2, associados a emissões veiculares. O biomonitoramento, realizado em 2018, revelou enriquecimento de Mn, Zn e Cd na maioria dos locais. A T. stricta apresentou maiores FE, que pode estar relacionado com os locais de origem ou fisiologia das plantas. Uma análise prévia de biomarcadores de estresse oxidativo revelou correlações entre metalotioneína e Fe, Mn, Co, Cu, Ni e Zn, indicando concentrações maiores que as fisiológicas para esses metais. As concentrações de outros biomarcadores como glutationa reduzida e H2O2 também foram avaliadas. / [en] This study aims to evaluate the influence of daily traffic and road construction of a new stretch of BR-040, between Duque de Caxias and Petrópolis, in the emission and composition of the particulate matter (PM) of the region. The construction works started in 2014 and were interrupted in June 2016. The traditional monitoring of PM and biomonitoring with transplanted Tillandsia usneoides and Tillandsia stricta were conducted at six sampling sites along the highway. The Laboratory of Atmospheric Pollution Studies (LEPA) provided filters containing total suspended particulates (TSP), collected between 2014 and 2016. inductively coupled plasma mass spectrometry (ICPMS) and ion chromatography (IC) were used to the chemical characterization of TSP. In 2014, the highest average concentrations of TSP were observed at points close to the toll. In 2016 there was no difference in TSP concentrations between periods with works and in their absence. The major element in the PTS was Fe and the greatest enrichment factors (FE) were obtained for Cu, Cd and Ni. The ions in higher concentrations were NO3 -and SO4-2 , associated with vehicular emissions. Biomonitoring, conducted in 2018, showed enrichment of Mn, Zn and Cd in most sites. T. stricta presented higher FE, which may be related to the sites of origin or physiology of the plants. A previous analysis of oxidative stress biomarkers revealed correlations between metallothionein and Fe, Mn, Co, Cu, Ni and Zn, indicating higher concentrations than the physiological ones for these metals. Concentrations of other biomarkers reduced glutathione and H2O2 were also evaluated.
115

Qualidade microbiológica do ar no centro de material e esterilização: avaliação do impacto da pressão negativa na área da limpeza / Microbiological quality of air in the Material and Sterilization Center: evaluation of the impact of negative pressure in the cleaning area

Almeida, Alda Graciele Claudio dos Santos 07 August 2018 (has links)
Introdução: Recomendações nacionais (RDC ANVISA 15/2012; 50/2002) e internacionais determinam que as áreas destinadas à limpeza dos produtos para saúde (PPS) no Centro de Material e Esterilização (CME) mantenham um diferencial de pressão negativo do ar ambiente (BRASIL, 2012; AAMI, 2006; ASHARE, 2013). Entretanto, essa recomendação, até o momento, não está sustentada por estudos de alto rigor científico. Embora não houvessem justificativas explicitadas para tal recomendação, presume-se que seja prioritariamente pelo risco de transferência aérea de microrganismos, da área de limpeza para as áreas adjacentes, configurando-se em risco ocupacional. Objetivo: Avaliar o impacto da presença da pressão negativa na área de limpeza do CME mediante a avaliação da qualidade microbiológica do ar desse setor e da área de preparo dos PPS. Método: Foram comparadas amostras microbiológicas do ar coletadas da sala de limpeza (área suja) e da sala de preparo (área limpa) de dois CME classe II de um mesmo hospital localizado na cidade de São Paulo: com e sem sistema de pressão negativa do ar na área de limpeza, este último com sistema de condicionamento do ar centralizado. Como controle, foram realizadas coletas do ar exterior ao hospital. Para obter amostras microbiológicas, foi utilizado o amostrador air six-stage Andersen, com os seguintes meios de cultura seletivos e não seletivo: agar sangue, agar sabouraud, Lowenstein jensen e agar legionella. Durante a coleta do ar, foram verificadas as seguintes variáveis: temperatura e a umidade relativa dos ambientes, número de pessoas presentes e equipamentos sendo utilizados na limpeza. Após as coletas, as amostras foram encaminhadas ao laboratório de ensaios microbiológicos da escola de enfermagem da Universidade de São Paulo, onde permaneceram em estufa microbiológica regulada a 35 ± 2ºC. Os dias de incubação foram específicos para recuperação pretendida de cada grupo microbiano quais sejam: bactérias vegetativas - incluindo Legionella, Mycobacterium tuberculosis e fungos. As placas com crescimento positivo foram submetidas a identificação do gênero e/ou espécie, por meio das características fenotípicas e reações específicas, pelo laboratório de microbiologia da Santa Casa de São Paulo. As amostras, tanto do CME com pressão negativa como naquele sem, foram coletas em quintuplicata. Resultados: a concentração de bioaerossóis na área da limpeza no CME sem pressão negativa e da área de preparo foi de 273,15 e 206,71 UFC/m3 respectivamente, enquanto, no CME com pressão negativa foi de 116,96 UFC/m3 na sala da limpeza e 131,10 na de preparo. Comparando a quantidade média de colônias isoladas dos CME estudados, a diferença foi significativamente menor (p=0,01541) no CME com pressão negativa. A relação I/E, onde I é a quantidade de fungos no ambiente interior e a quantidade de fungos no ambiente exterior, no CME com pressão negativa, na sala de limpeza foi de 0,5 e na sala de preparo de 0,58. No CME sem pressão negativa, a relação foi de 0,8 e 0,6, respectivamente, na sala de limpeza e preparo, ambos abaixo do padrão de referência, que deve ser 1,5, atualmente estabelecido pela resolução nº 9/2003 da ANVISA que dispõe sobre referenciais de qualidade do ar interior, em ambientes climatizados artificialmente de uso público e coletivo. Em nenhum dos CME foram recuperados Mycobacterium tuberculosis ou Legionella do ar. Os microrganismos identificados foram Penicillium spp, Aspergillus niger, Rhodotorula spp., Bacillus subtilis, e Micrococcus spp., todos considerados como não apresentando riscos à saúde em imunocompetentes. Conclusão: Os achados da presente investigação evidenciaram que o sistema de pressão negativa na sala de limpeza do CME contribuiu para redução quantitativa de bioaerossóis, tanto nesse ambiente como na sala de preparo. Entretanto, mesmo no CME sem esse sistema de tratamento do ar na sala de limpeza, a concentração de bioaerossóis foi menos da metade do padrão referencial estabelecido pela resolução nº 9/2003 da ANVISA, em que o valor máximo permitido deve ser 750 UFC/m3 de fungos. Ressalta-se que a quantidade e tipo de microrganismos existentes em qualquer ar ambiente é circunstancial, instável e principalmente dependente dos disseminadores microbianos presentes no local, sejam pessoas ou atividades. Nesse sentido, não se condena conclusivamente CME que não dispõe de pressão negativa na sala de limpeza configurando risco ocupacional. / Introduction: National (RDC ANVISA 15/2012) and international guidelines recommend that areas for cleaning medical devices in the Material and Sterilization Center maintain a negative differential ambient air pressure (BRAZIL, 2012; AAMI, 2006; ASHARE, 2013). However, this recommendation, so far, has not been supported by highly scientifically rigorous studies. Although there are no explicit justifications for such recommendations, it can be assumed that they are grounded on the risk of airborne microorganism contamination from the cleaning area to adjacent ones, which constitutes occupational risk. Objective: to evaluate the impact of negative air pressure on the microbiological quality of the air in the Material and Sterilization Center area where medical devices are cleaned and in the adjoining preparation room. Methods: Microbiological air samples were collected from the room where medical devices are cleaned (also called dirty room) and from the room where these devices are prepared (clean room) at two class II Material and Sterilization Center in the same hospital, located in the city of São Paulo: with and without a negative air pressure system in the cleaning room; the latter with central air conditioning. As a control, outdoor air samples were collected. To obtain microbiological air samples, Andersen six-stage air sampler was used, with the following selective and non-selective culture media: blood agar, sabouraud agar, Lowenstein Jensen and agar legionella. During air collection, the following variables were controlled: temperature and air relative humidity in the rooms, number of people present in the sites and equipment used for the cleaning. After the collection, the samples were sent to the Laboratory of Microbiological Trials of the Nursing School of the University of São Paulo, where they remained in a microbiological oven at a temperature of 35ºC ± 2. The incubation period was specific for the intended recovery of each microbial group: vegetative bacteria including Legionella and Mycobacterium tuberculosis and fungi. Identification of microorganisms` genus and / or species was carried out according to their phenotypic characteristics at the Microbiology Laboratory of the Santa Casa Hospital in São Paulo. The samples, in both Material and Sterilization Center, the one with negative pressure and the one without, were collected in a five-fold sample. Results: The concentration of bioaresols in the cleaning room and preparation area without negative pressure was 273.15 and 206.71 UFC / m3, respectively, while in the Material and Sterilization Center with negative pressure the concentration of bioaerosols was 116.96 CFU / m3 in the cleaning room, and 131.10 in the preparation area. The number of isolated colonies in the negative pressure Material and Sterilization Center was significantly lower (p = 0.01541). The I / E ratio, where I is the amount of fungi in the indoor environment, and E is the amount of fungi in the outdoor environment, in the cleaning room of the negative pressure Material and Sterilization Center was 0.5, and in the preparation area, 0, 58; as for the Material and Sterilization Center without negative pressure, in the cleaning and in the preparation area, the ratio was 0.8 and 0.6, respectively, both below the reference standard currently established by ANVISA Resolution No. 9/2003, which determines indoor air quality standards at artificially climatized environments for public use. In neither of the studied Material and Sterilization Center were Mycobacterium tuberculosis or Legionella recovered from the air. The microorganisms identified were Penicillium spp, Aspergillus niger, Rhodotorula spp., Bacillus subtilis, and Micrococcus spp., all of which are considered harmless to immunocompetent subjects. Conclusion: The findings showed that the negative pressure system in the Material and Sterilization Center cleaning room contributed to the quantitative reduction of bioaerosols, both in this area and in the adjoining preparation area. However, even in the Material and Sterilization Center whose cleaning room did not have this system the concentration of bioaerosols was less than half the reference standard established by ANVISA Resolution No. 9/2003. It should be stressed that the quantity and type of microorganisms in any ambient air is circunstancial, instable and, especially dependent on microbe disseminators in the site, whether they are people or activities. Therefore, it cannot be conclusively concluded that Material and Sterilization Center that do not have negative pressure in their cleaning rooms offer occupational risk.
116

Avaliação da qualidade do ar em duas estações do metrô de São Paulo / Air quality evaluation in two stations of the São Paulo Subway

Fujii, Reinaldo Keiji 14 September 2006 (has links)
Objetivo. Comparar a qualidade do ar externo com o ambiente interno das estações Clínicas e Praça da Sé do Metrô de São Paulo, quantificando e qualificando os contaminantes microbiológicos e atmosféricos. Propõe-se com este estudo promover o conhecimento de fatores sobre a qualidade do ar e das condições de higiene e saúde destes locais, contribuindo para a melhoria da qualidade de vida dos trabalhadores e usuários do sistema. Métodos. As amostras foram realizadas no período de Julho a Novembro de 2005. Os fungos foram coletados com o impactador de Andersen de um estágio com volume de aspiração de 28 l/min por um tempo de 10 minutos por amostra, e como meio de cultivo Agar Sabouraud Dextrose a 4 por cento . A quantificação e identificação foram feitas por meio de análises de lâminas do material microbiológico em microscópio óptico, coradas com azul de lactofenol. Para o dióxido de nitrogênio utilizou-se difusor passivo com trietanolamina como substância adsorvente e as análises foram realizadas por espectrofotometria. O difusor passivo para avaliação da concentração de benzeno é do tipo membrana, com carvão ativado como substância adsorvente e a análise por cromatografia gasosa. O tempo de exposição para estes amostradores foi de 30 dias. O PM10 foi medido com um monitor contínuo, com leitura direta. Foram instalados dois equipamentos em cada estação por um período de 7 dias. Resultados. Os estudos indicam a presença de fungos comuns com predominância para o Cladosporium sp (52 por cento ), Alternaria sp (17 por cento ) e Penicillium sp (13 por cento ) e em proporções semelhantes interna e externamente às estações. A concentração média de NO2 no interior das estações, foi de 73,9JPñ (VWHV YDORUHV Vão semelhantes às medições externas realizadas com o equipamento de Espectroscópia de Absorção por Diferencial Óptico (DOAS) e os valores medidos pela estação de monitoramento da CETESB, instalado na FSP/USP. Os valores viii máximos encontrados para o benzeno foram de 5,7JPñ QR LQWHULRU GDV estações e 6,2JPñQRDPELHQWHH[WHUQR230LQGLFRXYDORUHVHOHYDGRV sendo o valor médio, para a estação Clínicas de 312,4JPñ PHGLGRV QD SODWDIRUPDHJ/m³ no mezanino, na estação Praça da Sé verificamos a concentração de 150,9JPñ QD SODWDIRUPD GD OLQKD H JPñ QD plataforma da linha 3. Conclusões. O presente estudo possibilitou a avaliação e comparação dos níveis de poluição ambiental interno e externo às estações. A constatação da predominância de fungos comuns no ar não indica a ausência de riscos para a saúde humana, pois o seu impacto depende da suscetibilidade dos indivíduos expostos. A concentração de NO2 e benzeno encontradas no ambiente interno e externo são de mesma ordem de grandeza, o que indica que estes contaminantes têm a mesma fonte de origem. A alta concentração de PM10 representa uma maior preocupação. Para este contaminante deve-se avaliar a composição do material encontrado e seu grau de toxicidade / Objective. Compare the air quality outdoors with the indoors environment at Clínicas and Praça da Sé Stations of the São Paulo Subway, measuring the quantity and quality of the existing microbiological and atmospheric contaminants. The purpose of this study is to promote the knowledge of factors related to the air quality and the health and hygiene conditions in these places, contributing to the improvement of the quality of life of employees and users of the system. Methods. The samples were taken from July to November 2005. The fungi were taken by one-stage Andersen impactor with aspiration volume of 28 l/min for a period of 10 minutes per sample, making use of Agar Sabouraud Dextrose at 4 per cent for the culture. The quantification and identification are done by the analysis of slides with the microbiological material in an optical microscope, colored with lactofenol blue. For the nitrogen dioxide, a passive diffuser was used with triethanolamine as absorbing substance and the analysis was done by spectrophotometry, the passive diffuser used to evaluate the concentration of benzene is the membrane type with activated carbon as absorbing substance making use of gas chromatography analysis. The exposure period for these samplers was 30 days. The PM10 was measured with a continuous monitor, with direct reading. This equipment uses fibreoptic sensors for the identification of the size and concentration of the particles which are sucked by a diaphragm pump, passing through a measuring chamber which also measures the temperature and the air humidity. Two pieces of this equipment were installed in each station for a period of seven days. Results. The studies indicate the presence of ordinary fungi with the prevalence of Cladosporium sp (52 per cent ), Alternaria sp (17 per cent ) and Penicillium sp (13 per cent ) in similar proportions both indoors and outdoors. The indoor average concentration of NO2 was 69,5g/m³. These values are similar to the outdoor x results obtained with the equipment for Differential Optical Absorption Spectroscopy (DOAS) and the values measured by CETESB control station, located at FSP/USP. The values found for benzene ranged from 3,8 to 6,2g/m³, indicating an average of 5,0g/m³. The PM10 indicated high values with an average, at Clínicas Station, of 312,4 g/m³ measured in the platform and 243,9 g/m³ in the mezzanine. At Praça da Sé Station the concentration on the platforms was 150,9 g/m³ for line 1 and 124,2 g/m³ for line 3. Conclusions. The present study permitted the assessment and comparison of the environmental pollution levels inside and outside the stations. The verification of the predominance of common fungi in the air doesn\'t indicate the absence of risks for the human health, because it impact depends on the exposed individuals\' susceptibility. The concentration of NO2 and benzene found in the internal and external atmosphere are of same order of greatness, what indicates that these pollutants have the same origin source. The high concentration of PM10 represents a larger concern. This pollutant it should be evaluated the composition of the found material and his toxicity degree
117

Avaliação do impacto das emissões de metais geradas no coprocessamento de resíduos em fábricas de cimento / Impact assesment of metal emissions generated in cement mill waste coprocessing

Siqueira, Ligia Cristina Gonçalves de 14 September 2005 (has links)
Objetivo. Desenvolver um procedimento para a estimativa das emissões de metais resultantes do coprocessamento em fábricas de cimento para avaliação do seu impacto na atmosfera. Metodologia. Foram pesquisados os tipos de processo de produção de clínquer e a origem dos metais no sistema. Os teores de metais das correntes de entrada e saída do processo foram determinados por meio de coleta e análise de amostras das mesmas. Com esses dados foi realizado um balanço de massa para determinar a distribuição (%) dos metais, baseada na retenção em cada corrente. Depois foi realizada a estimativa das emissões de cada elemento, para comparação com padrões de emissão. As emissões estimadas e dados meteorológicos e topográficos, aplicados num modelo de dispersão atmosférica, permitiram a predição das concentrações de metais na atmosfera para avaliação de impactos. Foi realizado um estudo de caso com dados secundários para a aplicação da metodologia proposta. Resultados. Para alguns metais as emissões estimadas ultrapassaram limites estabelecidos na legislação estadual e federal. Com a aplicação do modelo de dispersão, também houve ultrapassagem da concentração de referência de alguns metais na atmosfera. Conclusão. O procedimento proposto foi válido para a estimativa das emissões e para avaliação do impacto da concentração de metais na atmosfera. Para melhor análise dos resultados, recomenda-se o desenvolvimento de Padrões de Qualidade do Ar para metais adequado à realidade brasileira ou procedimentos para análise de risco atmosférico no caso de metais tóxicos. Os resultados de impacto são válidos nas condições do estudo de caso e necessitariam ser verificados caso a caso / Objective. Develop a procedure to estimate metal emissions into the atmosphere, resulting from cement mill coprocessing, in order to evaluate their impact in the atmosphere. Methodology. Clinker production process types, and metal origin in the system were researched. Process material input, and output flow metal contents were determined by collecting, and analyzing samples obtained from them. With these data we calculated a mass balance to obtain each element\'s distribution (%), based on metal retention of each flow. Thus, each element\'s emission estimate was achieved, to be compared with emission standards. The estimated emissions, together with meteorological, and topographical data, applied to a model of atmospheric dispersion, permitted the forecasting of metal concentrations in the atmosphere, to asses their impacts. A case study with secondary data was performed to apply the proposed methodology. Results. For some metals, the estimated emissions would not comply with limits established in state, or federal legislation. Applying the dispersion model, we observed that some metals exceeded their reference atmospheric concentration in the atmosphere. Conclusion. The proposed procedure was valid to estimate emissions, and to asses metal concentration impact in the atmosphere. For a better analysis of the results, we recommend the development of Air Quality Standards for metals, appropriate to Brazilian reality, or of procedures to analyze atmospheric risk in the case of toxic metals. The results of the impact are valid in the case study conditions, and need to be checked case by case.
118

Gas concentrations and emissions and nutrient flow in broiler houses with litter reuse / Concentrações de gases e emissões e fluxo de nutrientes em aviários de frangos de corte com cama reutilizada

Angnes, Graciele 19 June 2017 (has links)
The commercial production of broiler chickens emits low amounts of nitrous oxide and methane, however, the production of CO2 and NH3 is considerable. Several countries have sought to investigate the emissions of greenhouse gases (GHG) and ammonia (NH3) in the production of broiler chickens since the information available in the literature is variable and uncertain. This is due to the diversity and particular conditions of the facilities, as well as the innumerable differences in the production system and the complex interactions observed in animal waste. Currently, gaseous pollutant measurements are costly techniques and difficult to put into practice in a large number of operations. The impacts of agriculture on global warming must be measured to allow Brazil to meet the commitments signed in COP-21 and to manage its production more precisely. In order to obtain reliable results, it is necessary to know the emission factors for the diverse production systems in the country. In view of this complexity, this research sought to apply a simplified sampling and emission determination technique that present low cost, simplicity, and robustness. The methodology uses the principle of concentration relations as a reference and determination of the concentration of gases was performed by INNOVA 1412. Weekly monitoring of concentrations of NH3, CO2, CH4, and N2O was conducted, considering the typical management of reused litter. The air quality was evaluated for the concentrations of NH3 and CO2, as recommended by international institutions. In addition, the thermal comfort of broiler house, considering the enthalpy index proposed in the literature and zootechnical performance, were measured. In order to identify the variables that best describe the emission flux of NH3 and CO2, mixed linear models with up to six variables were tested. N, C, and P balances were conducted for each production cycle in order to account for the inputs and outputs of the elements, as well as to verify the accuracy of the methodologies used. The main input of N, C, and P in the system was from reused litter, followed by the feed. The emissions allowed for the calculation of annual losses of 16 ± 4; 61 ± 16, and 168 ± 43 g of N2O, CH4, and NH3 bird-place-1 yr-1, respectively. Considering that this research presents an applicable and innovative methodology to determine GHG flows in broiler house for the country, the data will be useful for the Brazilian annual production of GHG emissions from poultry. The results are also useful to encourage new research that promotes knowledge of GHG emissions and alternatives to decrease emissions for meat production in Brazil. / A produção comercial de frangos de corte emite baixas quantidades de óxido nitroso e metano, no entanto, a produção de dióxido de carbono e amônia é considerável. Vários países têm buscado investigar as emissões de gases do efeito estufa (GEE) e amônia (NH3) na produção de frangos de corte já que as informações disponíveis na literatura são variáveis e incertas devido à diversidade das instalações, bem como das inúmeras diferenças no sistema de criação e das complexas interações observadas nos dejetos dos animais. Atualmente, a determinação das emissões gasosas exigem técnicas com custo elevado e difíceis de colocar em prática em um número elevado de instalações. Além disso, os impactos dos sistemas produtivos sobre o aquecimento climático devem ser medidos para permitir que o Brasil atenda os compromissos firmados na COP-21 e execute seu inventário de maneira mais precisa. A fim de obter resultados confiáveis é necessário conhecer os fatores de emissão na diversidade de sistemas de produção existentes no país. Diante dessa complexidade, nesta pesquisa buscou-se aplicar uma técnica simplificada de amostragem e determinação das emissões que apresenta baixo custo, simplicidade e robustez. A metodologia utiliza como referência, o princípio das relações de concentração e a concentração dos gases, que nesse casso foi determinada pelo INNOVA 1412. Buscou-se monitorar semanalmente as concentrações de NH3, CO2, CH4 e N2O considerando o manejo de reutilização da cama de frango. A qualidade do ar foi avaliada, considerando as concentrações de NH3 e CO2 recomendadas por instituições internacionais, assim como o conforto térmico dos aviários considerando os índices de entalpia propostos na literatura e o desempenho zootécnico. Determinou-se os fatores de emissão. E para identificar as variáveis que melhor descrevem o fluxo de emissão de NH3 e CO2, foram testados modelos lineares mistos com até seis variáveis. Balanços de N, C P foram conduzidos para cada ciclo de produção com a finalidade de contabilizar as entradas e saídas dos elementos e verificar a precisão das metodologias utilizadas. A principal entrada de N e C no sistema foi pela reutilização da cama, seguida pela ração. As emissões permitiram calcular perdas anuais de 16 ± 4; 61 ± 16; e 168 ± 43 g de N2O, CH4 e NH3 ave-alojada-1 ano-1, respectivamente. Considerando que esta pesquisa apresenta uma metodologia aplicável e de baixo custo para determinar as emissões de GEE em aviários de frangos de corte no Brasil, os resultados são úteis para incentivar novas pesquisas que possam avançar no conhecimento das emissões e possíveis técnicas de mitigação de GEE na produção de frangos de corte no Brasil.
119

Avaliação do impacto das emissões de metais geradas no coprocessamento de resíduos em fábricas de cimento / Impact assesment of metal emissions generated in cement mill waste coprocessing

Ligia Cristina Gonçalves de Siqueira 14 September 2005 (has links)
Objetivo. Desenvolver um procedimento para a estimativa das emissões de metais resultantes do coprocessamento em fábricas de cimento para avaliação do seu impacto na atmosfera. Metodologia. Foram pesquisados os tipos de processo de produção de clínquer e a origem dos metais no sistema. Os teores de metais das correntes de entrada e saída do processo foram determinados por meio de coleta e análise de amostras das mesmas. Com esses dados foi realizado um balanço de massa para determinar a distribuição (%) dos metais, baseada na retenção em cada corrente. Depois foi realizada a estimativa das emissões de cada elemento, para comparação com padrões de emissão. As emissões estimadas e dados meteorológicos e topográficos, aplicados num modelo de dispersão atmosférica, permitiram a predição das concentrações de metais na atmosfera para avaliação de impactos. Foi realizado um estudo de caso com dados secundários para a aplicação da metodologia proposta. Resultados. Para alguns metais as emissões estimadas ultrapassaram limites estabelecidos na legislação estadual e federal. Com a aplicação do modelo de dispersão, também houve ultrapassagem da concentração de referência de alguns metais na atmosfera. Conclusão. O procedimento proposto foi válido para a estimativa das emissões e para avaliação do impacto da concentração de metais na atmosfera. Para melhor análise dos resultados, recomenda-se o desenvolvimento de Padrões de Qualidade do Ar para metais adequado à realidade brasileira ou procedimentos para análise de risco atmosférico no caso de metais tóxicos. Os resultados de impacto são válidos nas condições do estudo de caso e necessitariam ser verificados caso a caso / Objective. Develop a procedure to estimate metal emissions into the atmosphere, resulting from cement mill coprocessing, in order to evaluate their impact in the atmosphere. Methodology. Clinker production process types, and metal origin in the system were researched. Process material input, and output flow metal contents were determined by collecting, and analyzing samples obtained from them. With these data we calculated a mass balance to obtain each element\'s distribution (%), based on metal retention of each flow. Thus, each element\'s emission estimate was achieved, to be compared with emission standards. The estimated emissions, together with meteorological, and topographical data, applied to a model of atmospheric dispersion, permitted the forecasting of metal concentrations in the atmosphere, to asses their impacts. A case study with secondary data was performed to apply the proposed methodology. Results. For some metals, the estimated emissions would not comply with limits established in state, or federal legislation. Applying the dispersion model, we observed that some metals exceeded their reference atmospheric concentration in the atmosphere. Conclusion. The proposed procedure was valid to estimate emissions, and to asses metal concentration impact in the atmosphere. For a better analysis of the results, we recommend the development of Air Quality Standards for metals, appropriate to Brazilian reality, or of procedures to analyze atmospheric risk in the case of toxic metals. The results of the impact are valid in the case study conditions, and need to be checked case by case.
120

Estudo sobre a ocorrência de poluentes emergentes na água do rio meia ponte na cidade de Goiânia- Go / Study of the occurrence of emerging pollutants in meia ponte river's water in Goiânia - Go

Fonseca, Yara Vanessa Portuguez 27 August 2013 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-09-30T17:52:25Z No. of bitstreams: 2 YARA VANESSA PORTUGUEZ FONSECA_ MARIANGELA FONTES SANTIAGO_ESTUDO SOBRE A OCORRÊNCIA DE POLUENTES EMERGENTES NA ÁGUA DO RI.pdf: 4799034 bytes, checksum: e87c5460f5118c81795e4d5e3a1b5884 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-09-30T18:17:45Z (GMT) No. of bitstreams: 2 YARA VANESSA PORTUGUEZ FONSECA_ MARIANGELA FONTES SANTIAGO_ESTUDO SOBRE A OCORRÊNCIA DE POLUENTES EMERGENTES NA ÁGUA DO RI.pdf: 4799034 bytes, checksum: e87c5460f5118c81795e4d5e3a1b5884 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-09-30T18:17:45Z (GMT). No. of bitstreams: 2 YARA VANESSA PORTUGUEZ FONSECA_ MARIANGELA FONTES SANTIAGO_ESTUDO SOBRE A OCORRÊNCIA DE POLUENTES EMERGENTES NA ÁGUA DO RI.pdf: 4799034 bytes, checksum: e87c5460f5118c81795e4d5e3a1b5884 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-08-27 / Several studies indicates the presence of emerging pollutants in surface water, these substances not covered by the legislation came from untreated effluent discharges The present study aimed to evaluate the occurrence of anthropogenic marker caffeine and emerging pollutants Triclosan, β-blockers (atenolol and propranolol), analgesics (ibuprofen, naproxen, diclofenac, carbamazepine) and hormones (estrone, 17-β-estradiol, 17α-ethinylestradiol , cyproterone acetate, gestodene and levonorgestrel) in water Meia Ponte River in the city of Goiânia-GO. By High Performance Liquid Chromatography - HPLC and fast Ultra High Performance Liquid Chromatography - UHPLC. Physical, chemical and microbiological parameters (turbidity, temperature, pH, Phosphorus, Total Solids, Filterable Solids, Total Coliforms, E. Coli, COD, conductivity, nitrate, DO, BOD) were analyzed to assess the changes of these characteristics during sampling. There were two sampling campaigns in one rainy season and another in the dry season. Samples were collected at six points in the watercourse Meia Ponte, within the boundaries of the Goiânia. The samples were analyzed by UHPLC at LBGQA (UFScar).The compounds analysed were caffeine, ibuprofen, naproxen, diclofenac, carbamazepine, atenolol, propranolol, triclosan, estrone, 17-β-estradiol, 17αethinylestradiol. The physical, chemical and microbiological and Water-Quality Index -WQI indicated that the same river at the point where this capture held in poor condition with evidence of contamination by sewage. Nine Of the eleven emerging pollutants studied were detected at concentrations between 0.61- ng. L-1 22 ng. L-1. The highest concentrations were found in point 3, after the release of STP(Sewage Treatment Plant) Hélio Seixo de Brito in the dry season and the lowest in point 1 where it is held to capture WTP (Water Treatment Plant) Eng Rodolfo José da Costa e Silva, in the rainy season. Caffeine (rainy season 17,91 – 12746,18 ng. L-1 dry season 20,52 – 22917,10 ng. L-1), triclosan (rainy season 2,68 – 6,01 ng. L-1 dry season 5,17 – 82,43,10 ng. L-1) and β-blockers (rainy season 0,61 – 475,76 ng. L-1 dry season 1,46 – 961,08 ng. L-1)were identified with 100% frequency, analgesics (rainy season 7,35 – 120,03 ng. L-1 dry season 4,17 – 404,71ng. L-1) had an average frequency of 70% and from the hormones analyzed, only estrone (<LOQ - 8.60 ng. L -1) was detected in the points after the STP Hélio Seixo Brito in the dry season. The load calculation in this study showed that the behavior of the load did not follow the concentration at all times for all compounds. Some compounds had greater input in the rainy season even when its highest concentration was found in the dry season and others maintained high loads independent of the flow. A PCA was calculated correlating emerging pollutants detected and physical parameters, chemical and microbiological. And was identified a correlation between collection points and also between the variables. / Diversos estudos indicam a presença de poluentes emergentes em água superficial essas substâncias não contempladas pela legislação são provenientes de lançamentos de efluentes com pouco ou nenhum tratamento. O presente estudo objetivou avaliar a ocorrência do marcador antrópico Cafeína e dos poluentes emergentes Triclosan, β-Bloqueadores (atenolol e propranolol), Analgésicos (ibuprofeno, naproxeno, diclofenaco, carbamazepina) e Hormônios (estrona, 17-β-estradiol, 17α-etinilestradiol, Acetato de ciproterona, Gestodeno e Levonorgestrel) na água do rio Meia Ponte na cidade de Goiânia-GO. Por meio da Cromatografia Líquida de Alta Eficiência – HPLC e Ultra rápida Cromatografia Líquida de Alta Eficiência – UHPLC. Parâmetros físicos, químicos e microbiológicos (Turbidez, Temperatura, pH, Fósforo, Sólidos Totais, Sólidos Filtráveis, Coliformes totais, E. Coli, DQO, Condutividade, Nitrato, OD, DBO) foram analisados para avaliar as alterações dessas características no momento da coleta. Foram realizadas duas campanhas amostrais uma no período chuvoso e outro no período de estiagem. As amostras foram coletadas em seis pontos no curso d’água Meia Ponte, dentro do perímetro do município de Goiânia. As amostras foram analisadas por meio do UHPLC do LBGqA da UFScar e os compostos cafeína, ibuprofeno, naproxeno, diclofenaco, carbamazepina, atenolol, propanolol, triclosan, estrona, 17-β-estradiol, 17α-etinilestradiol foram analisados. Os parâmetros físicos, químicos e microbiológico e o Índice de Qualidade Água- IQA indicaram que o rio mesmo no ponto onde realizada captação esta numa condição ruim com indícios de contaminação por esgoto. Dos onze poluentes emergentes estudados nove foram detectados com concentrações entre 0,61 ng. L-1 a 22µg.l-1. As maiores concentrações foram verificadas no ponto 3, após o lançamento da Estação de Tratamento de Esgoto- ETE Hélio Seixo de Brito no período de estiagem e as Engº Rodolfo José da Costa e Silva, no período de cheia. A cafeína (Cheia 17,91 – 12746,18 ng. L-1 estiagem 20,52 – 22917,10 ng. L-1), o triclosan (Cheia 2,68 – 6,01 ng. L-1 estiagem 5,17 – 82,43 ng. L-1) e os β-Bloqueadores (Cheia 0,61 – 475,76 ng. L-1 estiagem 1,46 – 961,08 ng. L-1), foram identificados com 100% de frequência, os analgésicos (Cheia 7,35 – 120,03 ng. L-1 estiagem 4,17 – 404,71 ng. L-1) tiveram em media 70% de frequência e dos hormônios analisados apenas a estrona (<LQ - 8,60 ng. L-1) foi detectada nos pontos após a ETE Hélio Seixo de Brito no período de estiagem. O cálculo das cargas neste estudo mostrou que o comportamento da carga não acompanhou o da concentração em todos os momentos para todos os compostos. Alguns compostos tinham maior presença na estação chuvosa mesmo quando sua maior concentração foi identificada no período de estiagem e outros mantiveram altas cargas independente da vazão do manancial. Foi calculado um PCA (análise de componentes principais) correlacionando os poluentes emergentes detectados e os parâmetros físico, químicos e microbiológicos e foi identificada uma correlação entre pontos de coleta e também entre as variáveis. menores no ponto 1 onde é realizada a captação da Estação de Tratamento de Água- ETA

Page generated in 0.1399 seconds