• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 6
  • 2
  • Tagged with
  • 217
  • 217
  • 125
  • 124
  • 60
  • 42
  • 38
  • 38
  • 36
  • 33
  • 33
  • 32
  • 29
  • 27
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Avaliação da qualidade do ar em unidades de terapia intensiva e sua correlação com o ambiente externo e a saúde dos trabalhadores / Evaluation of intensive care units air quality and its correlation with both external environment and workers\' health

Miyagusko, Marilia Jukemura 12 September 2008 (has links)
Nos locais de trabalho, a qualidade do ar pode interferir na performance dos trabalhadores e no risco de doenças. Sabe-se que a qualidade do ar interior pode ser afetada pelos poluentes gerados no ambiente exterior. Nos hospitais, estes temas têm sido insuficientemente analisados e nas unidades de terapia intensiva eles ainda não foram investigados. Os objetivos deste estudo foram analisar a correlação entre os níveis de poluentes medidos dentro e fora das unidades de terapia intensiva e investigar a associação entre a qualidade do ar nas unidades e a saúde dos trabalhadores. Oito unidades de terapia intensiva localizadas em quatro hospitais diferentes foram incluídas neste estudo. Níveis de poluentes, temperatura e umidade relativa do ar foram medidos dentro e fora das unidades, simultaneamente, durante períodos de sete dias específicos para cada unidade. Monitores automáticos foram usados para o monitoramento do MP2,5, enquanto monitores passivos foram usados para as medidas de NO2 e O3. Um questionário de sintomas foi aplicado a cada trabalhador das unidades de terapia intensiva que concordou em participar do estudo. Para testar diferenças nos poluentes e nas variáveis meteorológicas em cada unidade (dentro e fora) adotamos o teste t de Student ou o teste U de Mann-Whitney. Para testar diferenças entre a unidades nós adotamos o teste de análise de variância para amostras independentes (ANOVA) e o teste HSD-Tukey, quando necessário. Adotamos os coeficientes de correlação de Pearson ou de Spearman para avaliar correlações entre as medidas interiores e exteriores em cada unidade. Para as associações entre os sintomas e o local de trabalho nós adotamos o teste de qui-quadrado de Pearson ou o teste exato de Fisher. A unidade 1 apresentou a maior média interior de MP2,5 (33,9 g/m3; Desvio Padrão - DP = 44,2), estatisticamente diferente das demais unidades (p < 0,05). Além disso, este valor foi quase 16 vezes maior do que a média de MP2,5 observada na unidade 6 (2,1 g/m3; DP = 3,4), a menos poluída. Em cinco unidades, as medidas interiores e exteriores de MP2,5 apresentaram correlações estatisticamente significativas (p < 0,05). Tanto para o NO2 quanto para o O3, os valores exteriores foram maiores do que os interiores e não ouve correlação entre eles. Entre os 18 sintomas investigados, dores nas costas, ombros e pescoço (65%), cefaléia (65%), cansaço e fadiga (62%), tensão e irritabilidade (58%), coriza (51%), espirros (45%), vista cansada (44%), olhos secos (42%), dor de garganta (38%), dificuldade de concentração (35%) e tosse (27%) foram os mais relatados. As freqüências de sintomas foram semelhantes em todas as unidades. Não foram observadas associações entre a qualidade do ar interior e os sintomas relatados. Estes resultados mostraram que o isolamento entre os ambientes internos e externos através dos sistemas de ar condicionado pode variar permitindo altas concentrações de partículas finas interiormente. Além disso, a falta de correlações entre os gases dentro e fora das unidades indica a presença de fontes interiores para os dois poluentes. Potenciais associações entre a qualidade do ar nas unidades e sintomas de doenças requerem investigações adicionais / In work facilities, air quality can interfere in workers performance and in diseases´ risk. It is well known that indoor air quality can be affected by pollutants generated outdoor. In hospitals these topics have been insufficiently investigated and in intensive care units they have not been explored yet. The aims of this study were to analyze the correlation between indoor and outdoor levels of air pollutants in intensive care units and investigating the association between indoor air quality and workers health. Eight intensive care units located in four different hospitals were included in this study. Indoor and outdoor levels of air pollutants, temperature and relative humidity were measured simultaneously in each unit along unit-specific seven-day periods. Automatic monitors were used to measure PM2.5 while passive samplers were adopted to measure both NO2 and O3. A questionnaire of symptom was applied to each intensive care unit worker that agreed in participating of the study. In order to test differences in pollutants and weather variables measurements intra-units (inside and outside) we adopted the Student t test or Mann-Whitney U test. To test differences inter-units we adopted one-way analysis of variance for independent samples (ANOVA) and the Tukeys Honestly Significantly Different post-hoc test when necessary. We adopted Pearson correlation coefficients or Spearman correlation coefficients to investigate correlations between indoor and outdoor measures. For associations between symptoms and place of work we adopted qui-square test or Fishers exact test. Unit 1 presented the highest indoor PM2.5 mean (33.9 g/m3; Standard Deviation-SD = 44.2) and it was statistically different from all other indoor measures (p < 0.05). Also, it was almost sixteen fold higher than indoor PM2.5 mean in unit 6 (2.1 g/m3; SD = 3.4), the cleanest one. In five units, indoor and outdoor levels of PM2,5 presented statistically significant correlations (p < 0.05). For both NO2 and O3, outside values were higher than those measured inside and there were no correlations between indoor and outdoor measures. From 18 investigated symptoms, pain in back, shoulders or neck (65%), headache (65%), tiredness or fatigue (62%), tension and irritability (58%), runny nose (51%), sneezing (45%), eyestrain (44%), dry eyes (42%), sore and dry throat (38%), difficult of concentrating (35%) and cough (27%) were the most reported. Frequency of symptoms were similar in all units. There were not associations between indoor air quality and reported symptoms. These results showed that isolation between indoor and outdoor environments through air conditioning systems may vary allowing high indoor concentrations of fine particles. Moreover, the lack of correlation between indoor and outdoor gaseous pollutants indicates the presence of indoor sources of both pollutants. Potential associations between indoor air quality and disease symptoms require additional investigation
162

Contaminação aérea em cabines climatizadas: processo de avaliação e análise da influência de sistema de ventilação personalizado. / Airbone contamination in acclimatized cabins: process of evaluation and analysis of the influence of personalized ventilation system.

Conceição, Sandro Tavares 01 June 2012 (has links)
A disseminação de agentes infecciosos em ambientes interiores é um assunto de interesse da sociedade em geral e uma questão de saúde pública, tendo em vista os surtos recentes do vírus SARS, gripe suína, gripe aviária, etc. Em particular, o sistema com suprimento de ar individualizado têm se mostrado eficaz, atuando como barreira contra contaminação cruzada entre ocupantes. Diversas metodologias têm sido aplicadas nesses estudos, tal como gás traçador, geradores de partículas e simulação CFD, muitas vezes sem muito critério, ou com equipamentos e simulações excessivamente complexas. Neste contexto, o objetivo do presente trabalho é desenvolver um processo robusto e com menor complexidade do que os utilizados atualmente para avaliar a dispersão de contaminantes aéreos em ambientes interiores. O processo desenvolvido é aplicado em um estudo de caso onde a influência de um sistema de ventilação personalizado de cabine de aeronave é avaliado sobre a ótica da infecção cruzada. O trabalho contempla a realização de atividades de simulação computacional (CFD) e medições experimentais no ambiente interno de uma cabine de avião (mock-up), onde os campos de velocidade do ar são medidos com Velocimetria por Imagem de Partículas (PIV), partículas entre 2 e 10m são geradas com um gerador de aerossol e contadas com contadores ópticos portáteis. Obteve-se boa correlação entre os resultados numéricos e experimentais para o campo de velocidades e boa concordância qualitativa entre as contagens de partículas no experimento e nas simulações CFD Lagrangeanas. Observou-se, dentre outros aspectos, que a válvula gasper, tal como ensaiada no presente trabalho, contribui para a qualidade do ar na zona de respiração dos ocupantes sentados, promovendo um aumento nas taxas de deposição de partículas nas superfícies internas do mock-up. / The indoor dispersion of infections agents still concern the society, and has become a matter of public health, taken into account the outbreak of SARS in 2003, and the recent cases of influenza strains (H1N1, avian flu, SARS, etc). The use of personalized ventilation has improved the occupants\' air quality on recent evaluations, working as a contaminant spread barrier. Different kinds of methodologies are usually applied for those studies, such as tracer gas, particle generators and CFD simulations, sometimes without adequate criteria, or applying quite complex equipment and simulation methodologies such as transient analysis. Therefore, the main objective of the present work is to develop a robust method, and if possible less complicated than the current ones, to evaluate the dispersion of indoor airborne contaminants. Moreover, one\'s intend to apply the proposed method in a case study to evaluate the influence of a personalized ventilation system to the spread of indoor air contaminants. The study is composed by CFD simulations and experimental measurements inside an aircraft cabin mock-up, where the velocity and temperature field, as well as particle concentration are measured. Particle Image Velocimetry technique is used to analyse air flow velocities. Particles from 2 to 10µm are produced with aerosol generator and injected into the cabine. Finally, particle distributions are measured with hand held optical counters to evaluate air quality at the breathing zone. Good correlation between numerical and experimental results was obtained for velocity field, and adequate qualitative agreement was obtained for concentration field. One\'s conclude the investigated personalized ventilation system has improved the air quality around occupants breathing zone, mainly by increasing the deposition rates at the internal cabin surfaces.
163

Identificação de fontes de partículas finas na atmosfera urbana de São Paulo / Fine particulate emission sources identification in the atmosphere of São Paulo

Oyama, Beatriz Sayuri 03 May 2010 (has links)
Muitos estudos têm sido desenvolvidos com o intuito de descrever a química da fase gasosa na atmosfera da Região Metropolitana de São Paulo (RMSP). Contudo, o tratamento do material particulado (PM) ainda é feito de forma simplificada em modelos de transporte e químicos atmosféricos, apesar do grande conhecimento já adquirido na caracterização da sua composição elementar e da sua estrutura física. Tendo isso em vista, o objetivo do presente estudo é identificar as principais fontes emissoras do material particulado fino, em especial as fontes veiculares que apresentam muitas dificuldades para sua identificação por não haver medidas de traçadores específicos para os combustíveis utilizados. Neste trabalho foram realizadas amostragens, que duravam 24 horas, próximas a uma avenida de intenso tráfego (Avenida Dr. Arnaldo, na Faculdade de Medicina da Universidade de São Paulo) no período de junho de 2007 a agosto de 2008. Com os dados de composição dessas amostras, a identificação das possíveis fontes foi realizada por modelos receptores; mais especificamente foram utilizados: Análise de Fatores (AF) e Positive Matrix Factorization (PMF), uma nova ferramenta estatística, que ainda não havia sido aplicada no estudo do material particulado em São Paulo. O número de fontes identificadas por essas duas ferramentas estatísticas não foi o mesmo: na AF foram extraídos 4 fatores (solo, queima de óleo combustível e dois fatores que se dividiram, identificando a emissão de veículos leves e pesados não diferenciados), enquanto que o PMF identificou 6 (as mesmas fontes identificadas pela AF, com a diferenciação da emissão veicular (leves e pesados) e ainda a queima de biomassa). Houve concordância entre as duas análises que a maior participação para formação de material particulado fino é da emissão por veículos. A comparação entre os modelos mostrou que os resultados obtidos pelo PMF apresentaram uma melhor divisão das fontes, principalmente na identificação das frotas veiculares. Isso se deve ao fato do PMF considerar na análise o erro de cada concentração medida como um peso para cada variável, além de não permitir a ocorrência de fatores negativos, caracterizando melhor as fontes através da presença desses vínculos físicos. / Several studies have been developed in order to describe the gaseous phase of atmospheric constituents in the Metropolitan Region of Sao Paulo (RMSP). However, the aerosol description remains simplified in chemical models, despite the knowledge acquired in its characterization and composition analyses. Facing these limitations, the objective of this work is to identify the main emission sources of fine particulate matter, specially the vehicular ones that present a lot of difficulties due to the fact that the characteristic trace elements are unknown for these sources. It was used in this work 201 samples collected in 24-hour period each at Dr. Arnaldo Avenue, a large and busy avenue in the city of São Paulo, from June 2007 to August 2008. The source identification was accomplished considering the samples composition and using receptor models: Factor Analysis (FA) and Positive Matrix Factorization (PMF) techniques. PMF was a new statistical tool in the study of particulates in the city of São Paulo. The number of sources identified by these two models was different. The FA technique identified 4 factors, (soil, fuel burning, and 2 factors combining in light and heavy-duty vehicles), whereas PMF identified 6, the same as FA (light and heavier vehicles differentiated) and biomass burning. There was concordance between the two techniques, considering that both found that vehicular emission is the major contribution for concentration. The comparison between the models indicated that PMF model present a better source classification, mainly for the vehicular identification. The PMF technique considers the error of each sample in the analysis, weighting the variables and imposing that all the factors must be positive. This mechanism provides a better characterization of sources linking the results with the physics of the process.
164

Compostos orgânicos voláteis em tintas imobiliárias: caracterização e efeitos sobre a qualidade do ar em ambientes internos construídos / Volatile organic compound in paints: characterization and effects on air quality in indoor environments built

Patiño Guío, Lyda Milena 28 November 2013 (has links)
Materiais de construção como: adesivos, selantes, aglomerados, compensados, carpetes, revestimentos de parede, isolamentos, forros acústicos etc., emitem compostos orgânicos volateis (COVs) em ambientes internos (Niu e Burnett, 2001). No caso da tinta no Brasil, Salasar (2006) indica que \"as tintas à base de solventes emitem 520 vezes mais COVs em relação às tintas à base de água\". Consequentemente aumentos significativos na concentração de poluentes químicos e biológicos do ar em ambientes internos são provocados pelas baixas taxas de troca de ar em conjunto com a emissão de COVs originados pelos materiais de construção dos ambientes internos (Gioda & Neto, 2003). O objetivo nesta pesquisa é identificar compostos orgânicos volateis nas emissões de tintas imobiliárias usadas em ambientes internos na cidade de São Carlos. O laboratório foi realizado com o equipamento de cromatografia gasosa acoplado a espectrometria de massas, com siglas GC/MS, junto com o aparelho para extração da amostra chamado de micro extração de fase sólida (SPME), para duas amostras de cada tinta sendo uma fresca (úmida) e outra seca. O laboratório GC/MS quando é utilizado com micro extração de fase sólida (SPME) é o método mais aproximado do ideal, já que permite qualificar os COVs contidos nas amostras de tinta com maior eficiência que qualquer outro método (Koziel & Pawliszym, 2001). A escolha das tintas, esmaltes e o verniz foram determinadas como aquelas de maior uso e venda entre os pintores e lojas de tintas, respectivamente, na cidade de São Carlos. Os resultados mostraram que as tintas podem chegar a emitir juntas mais de 61 compostos orgânicos voláteis, a maior parte deles causa irritação respiratória e cinco desses compostos são suspeitos de desenvolver câncer, a concentração de cada composto não foi determinada. Uma suposição é que a saúde dos pintores pode estar sendo afetada, pois eles têm contato constante com as emissões das tintas, neste sentido é preocupante que esses trabalhadores da construção civil sejam informais, pois nesta condição o risco à sua saúde pode ser agravado devido à falta de capacitação necessária sobre a utilização do material que estão manipulando. Parte do resultado da pesquisa mostra também por meio de um questionário, as marcas de tintas imobiliárias comumente usadas na cidade de São Carlos, assim como uma noção sobre as doenças que as tintas produzem. O questionário foi elaborado para 40 pessoas entre pintores e vendedores de lojas de tinta na cidade de São Carlos. As fichas de segurança de produtos químicos FISPQ correspondentes para cada tinta omitem informações sobre alguns ingredientes considerados de risco encontrados nas amostras de tintas, como por exemplo, compostos suspeitos de desenvolver câncer. É importante para o Brasil a criação com urgência de um selo ambiental confiável que garanta a baixa concentração de emissão de COVs nas tintas como produto, mediante valores quantificáveis. Se similar ao selo \"Green Seal\", o mesmo daria não só uma forma de controle sobre a emissão de COVs nos prédios senão confiabilidade e garantia. O selo será um parâmetro de exigência nas certificações ambientais para confirmar as baixas emissões de COVs nos materiais das edificações sustentáveis, que até agora são inexistentes. / Building materials such as: Adhesives, sealants, plywood, carpeting, wall coverings, insulation, acoustic ceilings etc., emit volatiles organic compounds (VOCs) in indoor environments (Niu e Burnett, 2001). In the case of the paint in Brazil, Salasar (2006) indicates that \"solvent-based paints emit VOCs 520 times as compared to water-based paint.\". Consequently significant concentration of chemical and biological pollutants from indoor air, are caused by low rates of air exchange in conjunction with the emission of VOCs originating from the construction of the indoor materials (Gioda & Neto, 2003). The objective of this research is to identify volatile organic compounds (VOC) emissions from architectural coatings used indoors in São Carlos. The laboratory was performed with gas chromatography equipment coupled to mass spectrometry with acronyms GC/MS, with the instrument for sample extraction called solid phase micro extraction (SPME) for two samples of each paint: a fresh (wet) and a dry. The GC/MS laboratory when used with solid phase micro extraction (SPME) is the closest to the ideal method, allows to qualify the VOCs contained in the paint samples more efficiently than any other method (Pawliszym & Koziel, 2001). The choice of paints, enamels and varnish were determined as those of greater use and sale among painters and paint stores, respectively, in the city of São Carlos. The results showed that the paint can issue more than 61 volatile organic compounds, most of them cause respiratory irritation and five of these compounds are suspected of developing cancer, the concentration of each compound was not determined. One of the hypotheses is that the health of painters may be being affected, as they have constant contact with emissions from paints,in this respect it is wrong that these workers of the construction are informal, because in this condition the risk to your health can be aggravated due to lack of necessary training on the use of the material. Part of the search result also shows by means of a questionnaire , the marks of paints commonly used in the city of São Carlos, as well as a notion about the diseases that produce the paints. The questionnaire was designed in 40 people between painters and sellers of paint shops in the city of São Carlos. Safety data sheets for chemicals corresponding MSDS for each paint omit some information about ingredients considered risk in samples of paints, such as examples, compounds suspected of developing cancer. It is important for Brazil to urgently create a reliable environmental seal that ensures low emission concentration of VOCs in paints and product through quantifiable values . If the seal is similar to the seal \"Green Seal\", it would not only a form of control over the emission of VOCs in buildings too reliability and warranty The stamp will be a requirement parameter in environmental certifications to confirm low emissions of VOCs in materials of sustainable buildings , which until now are nonexistent.
165

Estudo de viabilidade de medidas de melhoria integrado na Certificação Energética e de Qualidade do Ar Interior de Edifícios de Serviços no âmbito do SCE/RSECE - DL 78 e 79/2006

Dias, Luís Filipe Fernandes January 2012 (has links)
Tese de Mestrado Integrado. Engenharia Mecânica. Faculdade de Engenharia. Universidade do Porto. 2012
166

Modelagem da influência de poluentes atmosféricos veiculares e fatores meteorológicos em afecções respiratórias

Nóbrega, Luciana Alves da 08 March 2013 (has links)
Made available in DSpace on 2015-05-14T12:47:14Z (GMT). No. of bitstreams: 1 ArquivoTotal.pdf: 5481354 bytes, checksum: 0c13ae5c154f04c9968451cecffae9ab (MD5) Previous issue date: 2013-03-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Until late 1980s, urban air pollution was attributed to industrial emissions. However, the fast urban growth in the developing nations caused the vehicles to become an issue of large magnitude. Nowadays, there is a situation in which the most responsible for the a relevant part of the air quality degradation in the bigger urban centers are the motor vehicles that are currently circulating on the roads, due to their great amount and poor state of repair. In some cities, the air pollutant concentration indexes have reached levels that threaten people's health, forcing the authorities to make decisions to control such problem. This current work aimed to verify the relationship among meteorological factors, vehicular air pollutants and the number of respiratory system disease cases notified by the department of health of Salvador-BA', by using the Poisson Regression Model. This investigation was conducted by using an ecological drawing made from secondary information about hospitalizations, collected from DATASUS and from data related to the monitoring of major air pollutants and to the meteorological parameters, from November 2010 to September 2012, acquired from the Environment and Water Resources Institute - INEMA. In this work, the most susceptible groups of people, that is, children (≤9 years old) and the elderly ( ≥65 years-old), were monitored. Acording to the achieved results, it was observed that the independent variables "SO2", "NO2", "CO" and "Temperature" were statistically relevant to justify the variability of the responds variable "Hospitalizations by respiratory system diseases" in children, to the exploratory level of 5%. Regarding to elderly, only the variables "NO2" and "O3" were statistically relevant to the significance level of 5%. Through the residual graphics and the diagnostic measures related to the Poisson model adjusted to the data about hospitalizations caused by respiratory system diseases in children and the elderly, it was possible to verify the proper suitability of the model used for the decision-making. / A poluição atmosférica urbana, até meados de 1980, era atribuída basicamente às emissões industriais, no entanto, o rápido crescimento urbano nos países em desenvolvimento fez com que os veículos se tornassem um problema de grande magnitude. Hoje se verifica uma situação em que os maiores responsáveis por grande parte da degradação da qualidade do ar nos grandes centros urbanos são os veículos automotores em circulação nas rodovias, devido à grande quantidade e péssimo estado de conservação. Em algumas cidades, os índices de concentrações de poluentes do ar passaram a atingir níveis que colocam em risco a saúde das pessoas obrigando as autoridades a tomar decisões para controlar este problema. o presente trabalho teve como objetivo verificar a relação entre fatores meteorológicos e poluentes atmosféricos veiculares com o número de casos de doenças respiratórias notificadas pela Secretaria de Saúde de Salvador-BA, mediante a utilização do Modelo de Regressão de Poisson. Essa investigação foi realizada utilizando-se um desenho ecológico a partir de informações secundárias de internações hospitalares coletados junto ao DATASUS e de dados acerca do monitoramento dos principais poluentes atmosféricos e dos parâmetros meteorológicos, no período de novembro de 2010 a setembro de 2012, adquiridos junto ao Instituto do Meio Ambiente e Recursos Hídricos - INEMA. Foram observadas neste estudo as populações mais suscetíveis que são crianças (< 9 anos) e idosos > 65 anos). De acordo com os resultados obtidos, observou-se que as variáveis "SO2", "NO2", "CO2", e "Temperatura" são estatisticamente significantes para justificar a variabilidade da variável resposta "internações por doenças respiratórias" em crianças, ao nível exploratório de 5%. Com relação aos idosos, apenas as variáveis "NO2" e "O3" foram estatisticamente significantes ao nível de 5% de significância. Através dos gráficos de resíduos e de medidas de diagnóstico referentes ao modelo de Poisson ajustados aos dados sobre internações por doenças do aparelho respiratório em crianças e idosos. Foi possível verificar a boa adequação do modelo utilizado para a tomada de decisão.
167

Avaliação analítica integrada de PM1 e nanopartículas atmosféricas

Schneider, Ismael Luís January 2016 (has links)
As nanopartículas atmosféricas podem causar diversos efeitos à saúde já que durante a inalação podem penetrar mais profundamente no sistema respiratório humano, atingindo inclusive os alvéolos e a corrente sanguínea, e, desta forma, aumentar os efeitos toxicológicos prejudiciais. Estas partículas podem ser emitidas diretamente para a atmosfera (partículas primárias) ou ser formadas por conversão gás-partícula (partículas secundárias). Durante a última década, estudos têm sido realizados para uma melhor compreensão sobre as concentrações de nanopartículas, avaliando sua emissão, formação, dispersão, exposição e os efeitos à saúde. No entanto, poucos estudos foram realizados no Brasil e desta forma ainda há pouca informação em relação a esta temática. A Região Metropolitana de Porto Alegre - RMPA (Brasil) possui forte tráfego veicular, cerca de 1,8 milhões de veículos e, apesar das fontes móveis impactarem fortemente a qualidade do ar nesta região e ser a principal fonte de nanopartículas, não há estudos que avaliem em profundidade os níveis deste importante poluente ambiental. Desta forma, no presente estudo foram avaliadas as concentrações de nanopartículas em diferentes pontos da RMPA. Além disso, foram avaliadas as concentrações ambientais de partículas <1 μm (MP1) e metais associados, bem como foram identificadas e quantificadas as contribuições de fontes utilizando o modelo receptor Positive Matrix Factorization (PMF). Em adição, foi realizada uma análise das assinaturas espectrais no infravermelho de nitro-hidrocarbonetos policíclicos aromáticos (nitro-HPAs) associados ao MP1. Este grupo de compostos orgânicos possui uma ampla distribuição no ambiente e, por possuírem propriedades mutagênicas e carcinogênicas, seus riscos ambientais foram calculados. Desta forma, considerando os resultados obtidos, verificou-se uma forte contribuição antropogênica dos poluentes avaliados na RMPA. Esta degradação da qualidade do ar está em geral associada ao tráfego veicular, especialmente no que se refere aos níveis de nanopartículas e nitro-HPAs associados ao MP1. Além disso, as emissões industriais, a queima de carvão, biomassa e óleo combustível, bem como a queima de combustíveis veiculares apresentaram forte influência nos níveis de metais observados em MP1. / Atmospheric nanoparticles can cause health effects, as during inhalation penetrate more deeply into the human respiratory system, including the alveoli and reaching the bloodstream, and thereby increase the damaging toxicological effects. These particles can be emitted directly to the atmosphere (primary particles) or be formed by gas-to-particle conversion (secondary particle). Over the last decade, studies have been conducted for a better understanding of the nanoparticles, assessing the emission, formation, dispersion, exposure and health effects. However, few studies have been conducted in Brazil and thus there is little information regarding this subject. The Metropolitan Area of Porto Alegre - MAPA (Brazil) has a strong vehicular traffic, about 1.8 million vehicles and, despite mobile sources strongly impact the air quality in this region and be the main source of nanoparticles, there are no studies that evaluate in depth the levels of this important environmental pollutant. Thus, considering this knowledge gap, the present study evaluated the nanoparticle concentrations in different sites of the MAPA. In addition, environmental concentrations of particles <1 μm (MP1) and associated metals were evaluated and the sources were identified and quantified using the receptor model Positive Matrix Factorization (PMF). In addition, an analysis of the infrared spectral signatures of nitro polycyclic aromatic hydrocarbons (nitro-PAHs) associated with PM1 was performed. This group of organic compounds has a wide distribution in the environment, and because they have mutagenic and carcinogenic properties, their environmental risks were calculated. Thus, considering the obtained results, a strong anthropogenic contribution of the evaluated pollutants in the MAPA was observed. This degradation of the air quality in general is associated with vehicular traffic, especially regarding the levels of nanoparticles and nitro-PAHs associated with PM1. In addition, industrial emissions, coal, biomass and fuel oil combustion, as well as vehicle fuels combustion had a strong influence on the metal levels observed in PM1.
168

Biomonitoramento da qualidade do ar com uso de liquens na cidade de Porto Alegre, RS

Käffer, Márcia Isabel January 2011 (has links)
Liquens são organismos em simbiose, considerados indicadores biológicos e, assim como os biomarcadores de genotoxicidade, são amplamente empregados para avaliar a qualidade do ar em áreas urbanas. Desta forma, este estudo teve por objetivos analisar a comunidade liquênica na cidade de Porto Alegre, RS, através do mapeamento da micota liquenizada e comparar a influência de determinados poluentes nas estruturas morfofisiológicas de algumas espécies liquênicas e na atividade mutagênica e citotóxica do material particulado atmosférico. A comunidade liquênica foi analisada, a fim de verificar alterações na sua estrutura, e danos morfofisiológicos em duas espécies (Parmotrema tinctorum e Teloschistes exilis), pela ação de determinados poluentes. Foram analisadas 30 estações amostrais, distribuídas em 29 áreas da cidade, e uma de referência no Parque Estadual de Itapuã, RS. Foram empregados o método do elástico para mapear os liquens, o método dos transplantes para analisar a ação de alguns poluentes atmosféricos e o ensaio Salmonella/microssoma para avaliar a mutagenicidade e citotoxicidade dos extratos orgânicos do PM10. Foram registrados 144 táxons liquênicos. Alterações na estrutura da comunidade liquênica foram verificadas nas áreas analisadas. Concentrações de poluentes, incluindo HPAs, foram constatadas nas espécies expostas, além de danos morfofisiológicos. Atividade mutagênica também foi verificada nos primeiros meses de exposição dos liquens, bem como a presença de nitrocompostos no ar. Na avaliação geral da comunidade liquênica urbana, constatou-se que fatores, como tráfego veicular, variáveis climáticas e topografia das estações amostradas, podem ter contribuído para os resultados encontrados. A utilização conjunta entre os bioindicadores e os biomarcadoress de mutagênese proporcionou a avaliação da qualidade do ar e o diagnóstico da presença de compostos agressivos ao meio ambiente. O emprego dos liquens como indicadores de alterações em ambientes urbanos são recomendados, podendo servir como ferramenta para programas de monitoramento nas cidades. / Lichens are symbiotic organisms considered as biological indicators and like genotoxicity biomarkers, are widely used to evaluate air quality in urban areas. Thus, the present study aims to analyze the lichen community in Porto Alegre, RS, by mapping lichenized mycota and also aims to compare the influence of certain pollutants morphophysiological structures of some lichen species and in the mutagenic and cytototoxicity activity in atmospheric particulate matter. The lichen community was analyzed in order to verify structure alterations, in addition to morphophysiological damages in two species (Parmotrema tinctorum and Teloschistes exilis) caused by the action of specific pollutants. Thirty sample stations were analyzed, distributed into twenty-nine areas in the city and a reference area in the State Park of Itapuã, RS. The band rubber method was used for mapping lichens, the transplant methodology was used in order to analyze the action of some atmospheric pollutants and the Salmonella/microsome assay was used to evaluate mutagenicity and cytotoxicity of PM10 organic extracts. One hundred and forty-four lichen taxa were registered. Alterations in the structure of the lichen community were verified in the analyzed areas. Pollutant concentrations, including PAHs were observed in the exposed species, in addition to morphophysiological damages. Mutagenic activity was also verified in the first months of lichen exposure, as well as the presence of nitrocompounds in the air. A general evaluation of the urban lichen community verified that traffic flow, climate variables and topography of the sampled stations may have contributed to the results obtained. The use of both bioindicators and mutagenesis biomarkers provided an evaluation of air quality and helped to determine of the presence of environmentalaggressive compounds. The use of lichens as indicators of alterations in urban environments is recommended and may serve as a tool for monitoring programs in cities.
169

Potencial bioindicador de cultivares de feijão (Phaseolus vulgaris L.) para o monitoramento do ozônio troposférico

Clebsch, Claudia Cristina January 2008 (has links)
O ozônio troposférico (O3) é um dos poluentes mais importantes da atualidade, sendo formado pela interação de óxidos de nitrogênio, hidrocarbonetos e radiação ultravioleta. Ele ou seus radicais livres estão associados ao aumento da incidência de doenças pulmonares em seres humanos, além de causar danos à vegetação e à produtividade agrícola em diversas regiões do mundo. Portanto, é de fundamental importância que sejam pesquisadas e padronizadas espécies e/ou cultivares sensíveis a este poluente, para que se possa fazer a bioindicação da qualidade do ar, uma vez que esta apresenta custo baixo e fácil implementação. Desta forma, o objetivo do presente trabalho foi avaliar o potencial bioindicador de 4 cultivares de feijão (Phaseolus vulgaris L.), desenvolvidas pela FEPAGRO (Fundação de Pesquisa Agropecuária) Litoral Norte do Rio Grande do Sul, através de sua comparação com a cultivar reconhecidamente sensível ao ozônio, a US Pinto 111. Para tanto, foram empregados parâmetros fotossintéticos, vazamento relativo de eletrólitos, abscisão foliar e medidas de biomassa. Plântulas de 8 dias (contados a partir da semeadura) das cultivares Fepagro 26, Guapo Brilhante, Iraí, Macotaço e US pinto 111 foram submetidas, em câmaras de topo-aberto, aos tratamentos sem e com adição de ozônio ao ar ambiente. Ao todo, foram realizados 7 eventos de fumigação, com duração de uma semana cada, e fumigação diária das 10:00 às 16:00 horas. Em cada um desses 7 eventos de fumigação, foram utilizadas 5 plântulas/tratamento/cultivar, totalizando 25 plântulas por câmara. A exposição ao ozônio causou, em algum momento, decréscimos significativos na assimilação líquida de todas as cultivares, exceto na Iraí. Esses decréscimos na assimilação líquida foram associados principalmente à atividade da Rubisco in vivo e, secundariamente, à capacidade de transporte de elétrons. A exposição ao ozônio causou também um aumento significativo no vazamento relativo de eletrólitos da cultivar Pinto, mas apenas quando a soma das concentrações horárias acima 40 ppb (AOT40) foi a mais elevada. Além disso, o tratamento com ozônio causou uma antecipação significativa no tempo de abscisão foliar apenas nas cultivares Pinto, Fepagro e Guapo, sendo que isto ocorreu em pelo menos um dos dois experimentos realizados para avaliação desse parâmetro. Quanto às medidas de biomassa da raiz, parte aérea e total da planta, pode-se dizer que períodos mais longos de exposição ao ozônio são necessários para ocorrerem modificações significativas e confiáveis nesse parâmetro. Embora tenha havido bastante instabilidade nos resultados, devido, provavelmente, a fatores ambientais não mensurados, pôde-se, com este estudo, confirmar a sensibilidade da cultivar US Pinto 111 ao ozônio e mostrar que a cultivar Fepagro 26 tem um ótimo potencial para ser empregada em estudos futuros como um bioindicador sensível ao ozônio, enquanto a cultivar Iraí poderia ser considerada resistente. Além disso, entre os parâmetros avaliados, a assimilação líquida e a abscisão foliar mostraram ser os mais eficientes para fazer a classificação das cultivares em níveis de sensibilidade. / Today, tropospheric ozone (O3) is one of the most important pollutants. It is formed by the interaction of oxides of nitrogen, hydrocarbons and ultraviolet radiation. It or its free radicals are associated with the increased incidence of lung diseases in humans, in addition to damage to vegetation and crop yield in different regions of the world. It is essential, therefore, to research and standardize species and/or cultivars sensitive to this pollutant, in order to be able to perform the bioindicator air quality, since this is low cost and easy to implement. The present study, thus, deal to evaluate the bioindicator potential of 4 bean (Phaseolus vulgaris L.) cultivars, developed by FEPAGRO (Fundação Estadual de Pesquisa Agropecuária) North Coast from Rio Grande do Sul, by comparing it with the cultivar that is known to be sensitive to ozone, US Pinto 111, using some parameters such as photosynthesis, relative leakage of electrolytes, foliar abscission and biomass measures. For this 8-day seedlings, counting from the date of sowing, of Fepagro 26, Guapo Brilhante, Iraí, were used for treatments with and without addition of ozone to the ambient air. In all, 7 fumigation events were performed, lasting one week each, and daily fumigation from 10 am to 4 pm. In each of these 7 fumigation events, 5 seedlings/treatment/cultivar were used, a total of 25 seedlings per chamber. Exposure to ozone at some point caused significant reductions in the net assimilation of all cultivars except Iraí. These reductions in net assimilation were associated mainly with the in vivo activity of Rubisco, and secondarily with the electron transport capacity. Exposure to ozone also caused a significant increase in the relative leakage of electrolytes from Pinto cultivar, but only when sum of daily concentrations above 40 ppb (AOT40) was highest. In addition, treatment with ozone caused a significant anticipation in foliar abscission time only in the Pinto, Fepagro and Guapo cultivars. This occurred in a least one of the two experiments performed to evaluate this parameter. As to the measures of root biomass, aerial part and total plant, it might be said that longer periods of exposure to the pollutant are necessary for significant, reliable changes to occur in this parameter. Although the results were quite unstable, probably due to unmeasured environmental factors, with this study one can confirm the sensitivity of US Pinto 111 cultivar to ozone and show that the Fepagro 25 cultivar has an excellent potential for future use as an ozonesensitive bioindicator, while the Iraí cultivar could be considered resistant. In addition, among the parameters evaluated in this study, net assimilation and leaf abscission proved to be most efficient to classify the cultivars as to levels of sensitivity.
170

Avaliação dos parâmetros físicos, químicos e microbiológicos do ar na unidade de terapia intensiva neonatal e no centro cirúrgico do Hospital Universitário Prof. Dr. Alberto Antunes HUPAA, Maceió-AL

Rita, Krystianelly Patrícia Pedrosa Santa 03 September 2010 (has links)
Intensive care units (ICU) and Surgical Center are noteworthy environments, because patients with poor health that frequent these places are subjected to acquire infections from the air of these environments. The aim of this study was to evaluate the air quality during the dry and rainy seasons of air-conditioned rooms of the NICU, neonatal intensive care unit, (A, B and C) , surgical center and exterior area at the University Hospital HUPAA/UFAL, Maceió-AL, for parameters recommended by ANVISA, and identify the mycoflora found and quantify the bacteria in the air. A number of 22 points of collects were performed, totaling 220 samples of air taken through the methodology specified by ANVISA s No. 9 Resolution, which consists in the definition of the parameters of bioaerosol, CO2, temperature, relative humidity, air velocity and aerialdispersoids. Macro and microscopic features were compared in order to identify the mycoflora and yeasts were identified by PCR with species-specific primers. From the 3.839 fungal colony forming units (CFU) isolated, 1.085 CFU were identified as belonging to 21 genera distributed among 63 species. Mycelia Sterilia with 121 CFU (11.1%) and Cladosporium cladosporioides with 78 CFU (7.2%) were the most frequent species in rainy season. Among the yeast species, Candida parapsilosis and C. tropicalis had the biggest frequency, both with four isolates corresponding to 4.7% each. The means were statistically significant for the parameters CO2, temperature, humidity and aerialdispersoids, not being significant for the air speed parameter. The observed values shows that the environments tested in the hospital were out of compliance for most of the parameters recommended by health surveillance in relation to the indoor air quality. Corrective measures are needed to remedy the possible sources of contamination in hospitals in order to comply with the four technical standards recommended by the National Agency for Sanitary Vigilance, contributing to the reduction of the levels of hospital infection, and the number of deaths related to it. / Fundação de Amparo a Pesquisa do Estado de Alagoas / As UTI s e o centro cirúrgico são ambientes hospitalares que merecem destaque, pois os pacientes nestes locais estão sujeitos a adquirir infecções provenientes do ar desses ambientes por apresentarem a saúde debilitada. O objetivo deste trabalho foi avaliar a qualidade do ar durante os períodos seco e chuvoso dos ambientes internos climatizados A, B e C da UTN, do centro cirúrgico e do ponto externo do Hospital Universitário HUPAA/UFAL, Maceió-AL, com relação aos parâmetros recomendados pela ANVISA, além de identificar a microbiota fúngica e quantificar as bactérias presentes no ar. Foram realizadas 22 coletas, totalizando 220 amostragens de ar realizadas através da metodologia indicada pela Resolução nº 9 da ANVISA que consiste na determinação dos parâmetros de bioaerossóis, CO2, temperatura, umidade relativa, velocidade do ar e aerodispersóides. Para identificação dos fungos filamentosos foram comparadas as características macro e microscópicas e as leveduras foram identificadas através da técnica de PCR com iniciadores espécie-específicos. Das 3.839 UFC fúngicas isoladas foram identificadas 1.085 UFC pertencentes a 21 gêneros distribuídos em 63 espécies, sendo Mycelia Sterilia com 121 (11,1%) UFC e Cladosporium cladosporioides com 78 (7,2%) UFC as espécies mais freqüentes no período chuvoso. Entre as leveduras, Candida parapsilosis e C. tropicalis foram as mais ocorrentes, ambas com quatro isolados correspondendo a 4,7% cada. As médias foram estatisticamente significativas para os parâmetros CO2, temperatura, umidade relativa, aerodispersóides e bioaerossóis, não sendo significativas para o parâmetro velocidade do ar. Os valores observados demonstram que os ambientes hospitalares estudados estavam fora de conformidade para maioria dos parâmetros recomendados pela vigilância sanitária em relação à qualidade do ar de interiores. Medidas corretivas são necessárias para remediar as possíveis fontes de contaminação nas unidades hospitalares de forma a atender as quatro normas técnicas preconizadas pela Agência Nacional de Vigilância Sanitária, contribuindo para minimizar os níveis de infecção hospitalar e o número de óbitos a esta relacionados.

Page generated in 0.0611 seconds