• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 532
  • 430
  • 99
  • 32
  • 24
  • 17
  • 13
  • 12
  • 12
  • 8
  • 8
  • 5
  • 5
  • 5
  • 5
  • Tagged with
  • 1512
  • 424
  • 393
  • 340
  • 234
  • 176
  • 138
  • 133
  • 129
  • 125
  • 125
  • 121
  • 118
  • 110
  • 107
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
341

Avaliação da resposta de detectores termoluminescentes na dosimetria de feixes clínicos utilizando diferentes objetos simuladores / Response evaluation of thermoluminescent detectors in clinical beams dosimetry using different phantoms

Matsushima, Luciana Cardoso 23 August 2010 (has links)
A radioterapia é uma das três principais modalidades de tratamento utilizadas no tratamento de doenças malignas, como o câncer; as duas outras são a quimioterapia e a radiocirurgia. Em contraste com outras especialidades médicas que necessitam principalmente de conhecimento clínico e da experiência de especialistas, a radioterapia, com o uso da radiação ionizante no tratamento do câncer, necessita de grandes investimentos em tecnologias modernas e do esforço colaborativo de diversos profissionais que contribuem para o sucesso do tratamento. Na área de dosimetria clínica, uma calibração eficiente e precisa do feixe de radiação garante o conhecimento da dose fornecida ao paciente, assegurando, portanto, o sucesso do tratamento radioterápico. Este trabalho tem por objetivo o estudo comparativo da resposta termoluminescente dos dosímetros de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN (6 mm de diâmetro e 0,8 mm de espessura) com a resposta dos dosímetros de fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti com 3,15 x 3,15 x 0,9 mm3) na dosimetria de feixes clínicos de fótons (6 e 15 MV) e elétrons (6 e 9 MeV) utilizando objetos simuladores de água sólida (RMI-457), água e PMMA. Foram obtidas as curvas de dose-resposta para a radiação gama do cobalto-60 (60Co) no ar e em condições de equilíbrio eletrônico (placa de PMMA), e para elétrons e fótons clínicos nas profundidades de dose máxima. Foi avaliada também a sensibilidade dos dosímetros termoluminescentes e determinada a reprodutibilidade da resposta e a eficiência intrínseca para os diferentes tipos de simuladores e energias de radiação estudadas. Os resultados obtidos indicam que a principal vantagem do dosímetro de CaSO4:Dy é a sua maior sensibilidade para as doses de radiação avaliadas para os feixes do 60Co, fótons e elétrons, representando, portanto, uma alternativa viável para a aplicação em dosimetria nos setores de radioterapia. / Radiotherapy is one of the three principal treatment modalities used in the treatment of malignant diseases such as cancer, the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. In the area of clinical dosimetry, an efficient and accurate calibration of the radiation beam ensures knowledge of the radiation dose delivered to the patient, allowing thus the success of radiotherapy. This study aims to compare the thermoluminescent response of calcium sulphate doped with dysprosium (CaSO4:Dy) dosimeters produced by IPEN (6 mm in diameter and 0,8 mm tick) with the response of lithium fluoride (3,15 x 3,15 x 0,9 mm3) doped with magnesium and titanium (LiF:Mg,Ti) in dosimetry of clinical photons (6 and 15 MV) and electrons beams (6 and 9 MeV) using solid water (RMI-457), water and PMMA phantoms. Initially, the dose-response curves were obtained for irradiation in cobalt-60 gamma radiation source in air (PMMA plates) and under electronic equilibrium conditions and for clinical electrons and photons beams at depth of maximum dose. The sensitivities of the thermoluminescent dosimeters were also evaluated and the values of their reproducibilities and intrinsic efficiency were determined for the response to differents types of phantoms and radiation energy. The obtained results indicate that the main advantage of CaSO4:Dy dosimeters is the enhanced sensitivity to radiation doses measured for 60Co, photons and electrons beams, thus representing a viable alternative for application in dosimetry in the radiotherapy area.
342

Dosimetry comparison between treatment plans computed with Finite size pencil beam algorithm and Monte Carlo algorithm using InCise™ Multileaf collimator equipped CyberKnife® System

Unknown Date (has links)
Since the release of the Cyberknife Multileaf Collimator (CK-MLC), it has been a constant concern on the realistic dose differences computed with its early-available Finite Size Pencil Beam algorithm (FSPB) from those computed by using industry well-accepted algorithms such as the Monte Carlo (MC) dose algorithm. In this study dose disparities between FSPB and MC dose calculation algorithms for selected CK-MLC treatment plans were quantified. The dosimetry for planning target volume (PTV) and major organs at risks (OAR) was compared by calculating normalized percentage deviations (Ndev) between the two algorithms. It is found that the FSPB algorithm overestimates D95 of PTV when compared with the MC algorithm by averaging 24.0% in detached lung cases, and 15.0% in non-detached lung cases which is attributed to the absence of heterogeneity correction in the FSPB algorithm. Average dose differences are 0.3% in intracranial and 0.9% in pancreas cases. Ndev for the D95 of PTV range from 8.8% to 14.1% for the CK-MLC lung treatment plans with small field (SF ≤ 2x2cm2). Ndev is ranged from 0.5-7.0% for OARs. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2018. / FAU Electronic Theses and Dissertations Collection
343

Development of an Arduino-based 3D printed 6DOF robotic phantom and a MATLAB-based software for Radiation Therapy Quality Assurance

Unknown Date (has links)
Quality Assurance (QA) for medical linear accelerators (linac) is the primary concern in external beam radiation therapy. In this research, we have developed a MATLAB-based software named Quality Assurance for Linacs (QALMA), which is unique, due to cost-effectiveness, user friendly interface, and customizability. It includes five modules to perform different QA tests: Star Shot analysis, Picket Fence test, Winston-Lutz test, MLC log file analysis, and verification of light & radiation field coincidence. We also pay attention to quality assurance of 6DOF treatment couch that plays a very important role in radiation therapy. We developed an Arduino based 3D printed 6DOF robotic phantom to check the accuracy of the treatment couch. This robotic phantom was experimentally validated under clinical standards, and customizable upon requirements of the quality assurance Task. The current features of this robotic phantom open development opportunities beyond the specific couch application, such as organs motion simulation. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2018. / FAU Electronic Theses and Dissertations Collection
344

Modelo de radionecrose cutânea induzida em camundongos nude (Nu/Nu) para desenvolvimento de terapias regenerativas baseadas em substitutos dermo-epidérmicos humanos / Radionecrosis skin model induced an athymic mouse nude (Nu/Nu) for development of dermal-epidermal human substitute based regenerative therapy

Rodrigo Crespo Mosca 29 April 2014 (has links)
A incidência de neoplasias tem aumentado expressivamente nos últimos anos e o contínuo crescimento populacional, bem como seu envelhecimento, aumentará de forma significativa a estatística desta enfermidade nas doenças mundiais. O tratamento das neoplasias geralmente consiste do uso singular ou combinado entre a quimioterapia, cirurgia e radioterapia dependendo da etiologia do tumor. Nos casos onde a radioterapia é empregada, além dos efeitos terapêuticos da radiação, podem ocorrer complicações específicas e, na pele, estas complicações podem se apresentar com uma expressão clínica que varia desde o eritema cutâneo até a radionecrose, sendo este ultimo o efeito adverso com maior gravidade. O tratamento para a radionecrose consiste no desbridamento das áreas necróticas e recobrimento do leito cirúrgico. Os enxertos autólogos são mais comumente usados para este recobrimento, entretanto quando grandes áreas são afetadas, os aloenxertos são uma alternativa de tratamento oclusivo e ainda, com a adição de queratinócitos e células mesenquimais derivadas da gordura (ADSC), torna-se uma alternativa por seu conhecido papel imunomodulatório e regenerativo. Neste sentido, visando simular os efeitos adversos da radionecrose, foi criado um modelo animal de radionecrose cutânea induzida em camundongos Nude (Nu/Nu) para o desenvolvimento de terapias regenerativas baseadas em substitutos dermoepidérmicos humanos contendo, queratinócitos e ADSC, que se mostrou eficiente como tratamento oclusivo. Além disso, com este modelo animal de radionecrose estabelecido, novas possibilidades de tratamento de enfermidades envolvendo regeneração cutânea, podem ser testadas. / The neoplasms incidence has increased significantly in recent years and continued population growth and aging will increase the statistics of this illness in the world\'s diseases. The cancer treatment usually consists in individual or combined use of chemotherapy, surgery and radiotherapy depending on the etiology of the tumor. In cases where radiotherapy is used in addition to the therapeutic effects of radiation, specific complications can occur, and in the skin, these complications can be present with a clinical expression ranging from erythema to radionecrosis, and this latter being the adverse effect with greater severity. The radionecrosis treatment consists in debridementing necrotic areas and covering the surgical wounds. Autologous grafts are most commonly used for this covering, however when large areas are affected, allografts can be used for occlusive treatment and the keratinocytes and adipose derived stem cells (ADSC) addition becomes an alternative, due to the knowing for immunomodulatory and regenerative response. For that reason, aiming to simulate the radionecrosis adverse effects, an animal model of induced cutaneous radionecrosis was created, in athymic mouse Nude (Nu/Nu), for developing regenerative therapies based on human dermal-epidermal substitutes containing keratinocytes and ADSC, which proved occlusive as an efficient treatment, furthermore, having this radionecrosis animal model established, new possibilities for treatment of diseases involving dermal regeneration, can be tested.
345

Emprego de simulação computacional para avaliação de objetos simuladores impressos 3D para aplicação em dosimetria clínica / Use of computational simulation for evaluation of 3D printed phantoms for application in clinical dosimetry

Caio César Santos Valeriano 29 May 2017 (has links)
O propósito de um objeto simulador é representar a alteração do campo de radiação provocada pela absorção e espalhamento em um dado tecido ou órgão de interesse. Suas características geométricas e de composição devem estar próximos o máximo possível aos valores associados ao seu análogo natural. Estruturas anatômicas podem ser transformadas em objetos virtuais 3D por técnicas de imageamento médico (p. ex. Tomografia Computadorizada) e impressas por prototipagem rápida utilizando materiais como, por exemplo, o ácido poliláctico. Sua produção para pacientes específicos requer o preenchimento de requisitos como a acurácia geométrica com a anatomia do individuo e a equivalência ao tecido, de modo que se possa realizar medidas utilizáveis, e ser insensível aos efeitos da radiação. O objetivo desse trabalho foi avaliar o comportamento de materiais impressos 3D quando expostos a feixes de fótons diversos, com ênfase para a qualidade de radiotherapia (6 MV), visando a sua aplicação na dosimetria clínica. Para isso foram usados 30 dosímetros termoluminescentes de LiF:Mg,Ti. Foi analisada também a equivalência entre o PMMA e o PLA impresso para a resposta termoluminescente de 30 dosímetros de CaSO4:Dy. As irradiações com feixes de fótons com qualidade de radioterapia foram simuladas com o uso do sistema de planejamento Eclipse™, com o Anisotropic Analytical Algorithm e o Acuros&reg XB Advanced Dose Calculation algorithm. Além do uso do Eclipse™ e dos testes dosimétricos, foram realizadas simulações computacionais utilizando o código MCNP5. As simulações com o código MCNP5 foram realizadas para calcular o coeficiente de atenuação de placas impressas expostas a diversas qualidades de raios X de radiodiagnóstico e para desenvolver um modelo computacional de placas impressas 3D. / The purpose of a phantom is to represent the change in the radiation field caused by absorption and scattering in a given tissue or organ of interest. Its geometrical characteristics and composition should be as close as possible to the values associated with its natural analogue. Anatomical structures can be transformed into 3D virtual objects by medical imaging techniques (e.g. Computed Tomography) and printed by rapid prototyping using materials, for example, polylactic acid. Its production for specific pacients requires fulfilling requirements such as geometric accuracy with the individual\'s anatomy and tissue equivalence, so that usable measurements can be made, and be insensitive to the radiation effects. The objective of this work was to evaluate the behavior of 3D printed materials when exposed to different photon beams, with emphasis on the quality of radiotherapy (6 MV), aiming its application in clinical dosimetry. For this, 30 thermoluminescent dosimeters of LiF:Mg,Ti were used. The equivalence between the PMMA and the printed PLA for the thermoluminescent response of 30 dosimeters of CaSO4: Dy was also analyzed. The irradiations with radiotherapy photon beams were simulated using the Eclipse™ treatment planning system,with the Anisotropic Analytical Algorithm and the Acuros&reg XB Advanced Dose Calculation algorithm. In addition to the use of Eclipse™ and dosimetric tests, computational simulations were realized using the MCNP5 code. Simulations with the MCNP5 code were performed to calculate the attenuation coefficient of printed plates exposed to different radiodiagnosis X-rays qualities and to develop a computational model of 3D printed plates.
346

Projeto estrutural de uma construção enterrada tipo bunker, destinada à instalação de equipamento acelerador linear de elétrons / Structural design of a bunker intended for installation of a linear accelerator of eletrons

Patrícia de Almeida 29 May 2018 (has links)
A radioterapia externa ocupa lugar de destaque nos tratamentos de câncer. As construções das salas que abrigam os aceleradores lineares são custosas e este fator é limitante para que sejam instalados mais equipamentos. Faz-se necessária a pesquisa de opções construtivas com objetivo de redução de custos, mantendo-se a estabilidade estrutural e a barreira de proteção radiológica. Para a blindagem destas instalações podem ser empregados diversos materiais para a atenuação de radiação. O concreto armado é empregado em muitas destas instalações, seja pelo seu custo ou a prática construtiva no Brasil, face ao notório conhecimento deste material e abundância de matéria prima. Foram elaborados dois projetos estruturais de bunker em concreto armado. O projeto denominado bunker enterrado foi concebido com estrutura localizada no subsolo e dimensionado levando-se em conta inclusive os esforços decorrentes do solo adjacente às paredes. Foi adotada blindagem de concreto no teto. As demais faces da construção tem atenuação de radiação por solo compactado. O projeto do bunker não enterrado considerou a geometria de um projeto padrão do Ministério da Saúde e o acesso é pelo pavimento térreo. Em função da espessura necessária de blindagem, foi projetada uma estrutura com dimensões que contemplam a barreira no teto e paredes. Os resultados obtidos neste estudo foram satisfatórios quanto aos dois modelos estruturais propostos, com vantagens e desvantagens. Foi mostrada a diferença de custos entre uma estrutura de edificação enterrada e outra não enterrada. A estrutura enterrada mostrou-se mais viável, pois aproveita o solo compactado adjacente para atenuação da radiação. / External radiotherapy occupies a prominent place in cancer treatments. The constructions of the rooms that shelter the linear accelerators are costly and this is a limiting factor to have more equipment installed. It is necessary to research construction options with the objective of reducing costs, maintaining the structural stability and the radiological protection barrier. For the shielding of these installations, various materials can be used for the attenuation of radiation. Reinforced concrete is used in many of these facilities, either for its cost or the constructive practice in Brazil, due to the know-how of this material and abundance of raw material. Two structural bunker structural projects were developed. The buried bunker project was designed with a structure located underground and dimensioned taking into account including the efforts from the soil adjacent to the walls. Concrete shield was used in the ceiling. The other faces of the construction have radiation attenuation by compacted soil. The not buried bunker project considered the geometry of a standard design of the Health Ministry and its access is by the ground floor. Due to the required thickness of shielding, a structure with dimensions that contemplate the barrier in the ceiling and walls was designed. The results obtained in this study were satisfactory, regarding the two proposed structural models, taking in consideration advantages and disadvantages. The difference in costs of a buried structure and not buried one was provided. The buried structure proved to be more viable, since it utilizes adjacent compacted soil to attenuate the radiation.
347

Desenvolvimento de um sistema de verificação dosimétrica tridimensional utilizando Solução Fricke gel na aplicação para a verificação da Radioterapia em Arco Modulado Volumétrico (VMAT) nos tratamentos com movimentação do alvo pela respiração / Verification system development a dosimetric tridimensional using Solution Fricke gel in the application for verification of radiation therapy in arc modulated volumetric (VMAT) in treatment with target moving for breathing

Sakuraba, Roberto Kenji 30 July 2015 (has links)
A Radioterapia em arco modulado volumétrico (VMAT) é uma das modalidades mais avançadas em teleterapia para o tratamento de câncer. Os diversos avanços tecnológicos, bem como a evolução das técnicas de tratamento tornaram o VMAT como uma das modalidades de estado da arte para o tratamento de alguns cânceres. Parte deste avanço é creditada à melhoria na acurácia e na prescrição de dose absorvida recomendada ao paciente ao longo dos anos. Este avanço permite que atualmente seja possível realizar os cálculos dosimétricos, por meio de sistemas de planejamento computadorizado, considerando as heterogeneidades dos pacientes, tais como: tecidos e órgãos com composições diferentes da água (meio de referência em radioterapia), contorno do paciente individualizado e o movimento dos tumores com a respiração. Tais avanços demandam o controle de qualidade destas ferramentas, com objetivo de assegurar que todo o processo de tratamento seja satisfatório e acurado. A comunidade dispõe poucos sistemas experimentais capazes de avaliar, considerando os níveis de incerteza, se os sistemas de planejamento computadorizados são aptos a considerar a movimentação dos alvos nos tratamentos com VMAT. Neste trabalho serão apresentados os resultados obtidos empregando um objeto simulador Fricke Xylenol Gel, com capacidade de mensurar as diferenças introduzidas pela movimentação, utilizando Imagem por Ressonância Magnética - MRI e comparando qualitativamente e quantitativamente os resultados. São discutidas as principais etapas de desenvolvimento deste objeto simulador, seus resultados experimentais, conclusões. / Volumetric Modulated Arc Therapy (VMAT) is one of the methods most commonly used in teletherapy to treat cancer. The various technological advances and the evolution of treatment techniques made the VMAT as one of the state of the art methods for the treatment of some cancers. Part of this improvement is credited to improvements in accuracy and prescription dose absorbed recommended to the patient over the years. This advance allows currently is possible to perform dosimetric calculations by means of the computerized planning system, considering the heterogeneity of patients, such as tissues and organs with different water compositions medium (reference radiation), and individual patient contour the movement of tumors breathing. Such advances require quality control of these tools, in order to ensure that the entire treatment process is satisfactory and accurate. Up to now, the community lacks an experimental system capable of evaluating, considering the uncertainty levels if the computerized planning systems are able to consider the movement of targets in the treatments with VMAT. In this paper, will be presented the results obtained with the phantom Fricke Xylenol Gel, capable of measuring the differences introduced by movement using the Magnetic Resonance Image - MRI and compared qualitatively and quantitatively. The main stages of the phantom development, their experimental results, conclusions and comparisons with other systems are discussed.
348

Desenvolvimento de cálculo de unidades monitoras para IMRT / Developement of monitor unit calculation in IMRT

Flosi, Adriana Aparecida 09 December 2011 (has links)
A verificação de forma independente do cálculo de dose e de unidades monitoras num plano de tratamento de IMRT é um passo importante nos procedimentos de garantia de qualidade da técnica em questão. Atualmente este verificação é baseada apenas em medidas experimentais demoradas e trabalhosas. Neste trabalho foi desenvolvido uma metodologia de cálculo de unidades monitoras de forma independente como uma nova ferramenta para garantir a qualidade e exatidão dos tratamentos de IMRT. Os valores encontrados se aproximam bastante dos valores calculados pelo sistema de planejamento utilizado, de forma que o algoritmo de cálculo desenvolvido apresentou uma concordância dentro de ± 1,8 % para uma geometria simples. Após diversos testes e com os níveis de ação devidamente estabelecidos, a verificação independente da unidade monitora para planos de tratamento de IMRT se tornará uma ferramenta efetiva e eficiente no controle de qualidade que ajuda a identificar e reduzir possíveis erros de tratamento em radioterapia. Como contribuição original deste trabalho, assegura-se aos serviços de Radioterapia a utilização da metodologia desenvolvida como ferramenta de controle de qualidade em tratamentos com IMRT. Em especial aos serviços que não dispõem de recursos econômicos para adquirirem softwares comercialmente disponíveis para o cálculo independente da unidade monitora. / Independent verification of dose calculations and monitor units settings of IMRT treatment plans is an important step in the quality assurance procedure for IMRT technique. At present, the verification is mainly based on experimental measurements, which are time consuming and laborious. In this work an independent methodology of monitor units calculation was developed as a new tool for IMRT treatments quality and precision assurance. The values found are near those calculated by the treatment planning system used, in a manner that the calculation algorithm demonstrated ± 1,8 % concordance in a simple geometry with the system. After several tests and the levels of action well established, the independent monitor units verification for IMRT treatment plans will become an effective and efficient tool in quality assurance, helping identification and the reduction of possible mistakes in radiotherapy treatments. To radiotherapy services is assured the use of the developed methodology as a tool of quality control in IMRT treatments as an original contribution of this work, specially those that do not dispose financial resources to acquire commercially available independent monitor unit calculus software.
349

Os significados da experiência da radioterapia oncológica na visão de pacientes e familiares cuidadores / The meanings of the experience of the radiotherapy oncológica in the vision of patients and family caretakers

Muniz, Rosani Manfrin 29 May 2008 (has links)
O presente estudo teve como objetivo compreender os sentidos da experiência da radioterapia oncológica para o paciente e o familiar cuidador, e integrá-los em significados socialmente construídos, por meio da análise etnográfica interpretativa. Para isso tomou-se apoio no referencial teórico da antropologia interpretativa de Clifford Geertz, da corrente da antropologia médica e do método da etnografia em centros urbanos. Foi uma pesquisa com abordagem metodológica qualitativa, realizada no Centro Regional de Oncologia em um município do sul do Brasil. Participaram do estudo 20 informantes, sendo 10 pacientes e 10 familiares cuidadores, que freqüentaram o serviço no período de março a agosto de 2007. Para a coleta de dados foram realizadas observações participantes e entrevistas semi-estruturadas no domicílio dos informantes, durante o período da radioterapia e trinta dias após o seu término; também foram elaborados os genograma e ecomapa para a contextualização dos informantes. A análise dos dados apoiou-se nos pressupostos analíticos de Hammersley e Atkinson, dentre outros autores. Foram identificados os códigos que apontaram o sentido da experiência para os informantes e que, posteriormente, serviram de guia para as unidades de sentidos e a construção dos núcleos de significados: \"Do adoecer por câncer à radioterapia - uma trajetória construída\"; \"A experiência da radioterapia: remédio e veneno\" e \"As teias da sobrevivência oncológica\". No primeiro núcleo, abordo os sentidos atribuídos para a trajetória do diagnóstico do câncer e o seu sentido impactante de morte, a via crucis pelo serviço de saúde público e as decisões terapêuticas, além da incorporação da identidade da pessoa como paciente oncológico, com o apoio das redes sociais, como a família, os amigos e a religião. O segundo tema versa sobre a entrada dos informantes no mundo da radioterapia, que se revelou como um momento desgastante, angustiante e sofrido; porém, também teve o sentido de um combate, uma vez que os pacientes submeteram-se à terapêutica com a visão de um remédio-veneno, poderoso e capaz de aniquilar o câncer e possibilitar a cura. No terceiro tema, abordei o tecer da teia para os informantes se ajustarem à nova vida e ao surgimento da nova identidade: a de sobrevivente do câncer. Nessa nova identidade, eles retomaram as atividades diárias e planejaram o futuro com esperança, apesar de uma sombra de incerteza em relação à cura. Finalizei com a consideração de que o significado da experiência da radioterapia oncológica para esse grupo de pessoas, da classe popular, significou a necessidade de submeter-se a uma terapêutica com uma característica de remédio-veneno que causa temor, mas que é necessária, se a perspectiva de vida é a cura ou mesmo a sobrevivência ao câncer. / The study aimed at understanding the senses of the experience of the radiotherapy oncologyc for the patient and the relative caretaker, and to integrate them in meant socially built, through the analysis interpretative ethnographic. For that was taken support in the theoretical referential of Clifford Geertz\'s interpretative anthropology, of the current of the medical anthropology and of the method of the ethnography in urban centers. It was a research with qualitative methodological approach, accomplished in the Regional Center of Oncology and Radiotherapy in a municipal district of the south of Brazil. Took part of the study 20 informers, being 10 patient and 10 family caretakers, which frequented the service in the period of March to August of 2007. For the collection of data, participant observations and semi-structured interviews were accomplished in the home of the informers, during the period of the radiotherapy and thirty days after the end of the treatment, and also elaborated genogram and ecomap for the contextualization of the informers. The analysis of the data was supported on the analytical presuppositions of Hammersley and Atkinson, among other authors. It was identified the codes that pointed the sense of the experience for the informers and that, later, they served as guide for the units of senses and the construction of the meanings nucleus: \"Of getting sick for cancer to the radiotherapy - a trajectory built\"; \"The experience of the radiotherapy: medicine and poison\" and \"The webs of the survival oncologic\". In the first nucleus, were approached the senses attributed for the trajectory of the diagnosis of the cancer and its sense of impact of death, the via crucis for the public service of health and the therapeutic decisions, besides the incorporation of the person\'s identity as a oncological patient with the support of the social nets, as the family, the friends and the religion. The second turns on the entrance of the informers in the world of the radiotherapy, that was revealed as a moment stressful, distressing and suffered; however, it also had the sense of a combat, once the patients underwent the therapeutics with the vision of a medicine-poison, powerful and capable of to annihilate the cancer and to make possible the cure. In the third theme, it was approached weaving of the web for the informers if they adjust to the new life and the appearance of the new identity: the one who survivor to the cancer. In that new identity, they retook the daily activities and they planned the future with hope, in spite of an uncertainty shadow in relation to the cure. It was concluded with the consideration that the meaning of the experience of the radiotherapy for that group of people, of the popular class, meant the need to submit to a therapy with a characteristic medicine-poison that causes fear, but that is necessary, if the life perspective is the cure or even the survival to the cancer.
350

Caracterização das propriedades dosimétricas de diodos de silício empregados em radioterapia com feixe de fótons / Dosimetric properties characterization of silicon diodes used in photon beam radiotherapy

Bizetto, César Augusto 22 May 2013 (has links)
No presente trabalho foi estudada a resposta de diodos epitaxiais (EPI) e fusão zonal (FZ) como dosímetros on-line em tratamentos radioterápicos com feixe de fótons na faixa de megavoltagem (diodo tipo EPI)e ortovoltagem (diodos tipo EPI e FZ). Para serem usados como dosímetros os diodos foram encapsulados em sondas de polimetilmetacrilato preto (PMMA). Para as medidas da fotocorrente os dispositivos foram conectados a um eletrômetro Keithley® 6517B no modo fotovoltaico. As irradiações foram feitas com feixes de fótons de 6 e 18 MV (acelerador Siemens Primus®),6 e 15 MV (acelerador Novalis TX®) e 10, 25, 30 e 50 kV de um equipamento de Radiação X Pantak/Seifert. Nas medidas com o acelerador Siemens Primus® os diodos foram posicionados entre placas de PMMA a uma profundidade de 10,0 cm e com o acelerador Novalis TX® mantidos entre placas de água sólida a uma profundidade de 5cm. Em ambos os casos, os diodos foram centralizados em campos de radiação de 10 × 10 cm2, com distância fonte superfície (DFS) mantida fixa em 100 cm. Para as medidas com os feixes de fótons deortovoltagem os diodos foram posicionados a 50 cm do tubo em um campo de radiação circular de 8 cm de diâmetro. A linearidade com a taxa de dose foi avaliada para as energias de 6 e 15MV do acelerador Novalis TX® variando-se a taxa de dose de 100 a 600 unidades monitoras por minuto e para o feixe de 50 kV variando-se a corrente do tubo de 2 a 20 mA. Todos os dispositivos apresentaram respostas lineares com a taxa de dose e dentro das incertezas, independência da carga com a mesma. Os sinais de corrente mostraram boa repetibilidade, caracterizada por coeficientes de variação em corrente (CV) inferiores a 1,14%(megavoltagem) e 0,15%(ortovoltagem) e em carga menores que 1,84% (megavoltagem) e 1,67% (ortovoltagem). Foram obtidas curvas dose-resposta lineares com coeficientes de correlação linear melhores que 0,9999 para todos os diodos. / In the current work it was studied the performance of epitaxial (EPI) and float zone (FZ) silicon diodes as on-line dosimeters for megavoltage (EPI diode) and orthovoltage (EPI and FZ diode) photon beam radiotherapy. In order to be used as dosimeters the diodes were enclosed in black polymethylmethacrylate (PMMA) probes. The devices were then connected, on photovoltaic mode, to an electrometer Keithley® 6517B to allow measurements of the photocurrent. The irradiations were performed with 6 and 18 MV photon beams (Siemens Primus® linear accelerator), 6 and 15 MV (Novalis TX®) and 10, 25, 30 and 50 kV of a Pantak / Seifert X ray radiation device. During the measurements with the Siemens Primus® the diodes were held between PMMA plates placed at 10.0 cm depth. When using Novalis TX® the devices were held between solid water plates placed at 50 cm depth. In both casesthe diodes were centered in a radiation field of 10 x 10 cm2, with the source-to-surface distance (SSD) kept at 100 cm. In measurements with orthovoltage photon beams the diodes were placed 50.0 cm from the tube in a radiation field of 8 cm diameter. The dose-rate dependency was studied for 6 and 15 MV (varying the dose-rate from 100 to 600 monitor units per minute) and for the 50 kV beam by varying the current tube from 2 to 20 mA. All devices showed linear response with dose rate and, within uncertainties the charge collected is independent of dose rate. The current signals induced showed good instantaneous repeatability of the diodes, characterized by coefficients of variation of current (CV) smaller than 1.14% (megavoltage beams) and 0.15% for orthovoltage beams and coefficients of variation of charge (CV) smaller than 1.84% (megavoltage beams) and 1.67% (orthovoltage beams). The doseresponse curves were quite linear with linear correlation coefficients better than 0.9999 for all diodes.

Page generated in 0.0554 seconds