• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1438
  • 201
  • 65
  • 65
  • 65
  • 64
  • 40
  • 15
  • 15
  • 15
  • 11
  • 10
  • 7
  • 2
  • 2
  • Tagged with
  • 1671
  • 625
  • 519
  • 402
  • 369
  • 313
  • 276
  • 274
  • 234
  • 210
  • 184
  • 163
  • 136
  • 136
  • 119
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Fuerza de adhesión de una resina compuesta indirecta con diferentes tratamientos de superficie utilizando un cemento autoadhesivo sobre esmalte, estudio in vitro

Suaquita Lupaca, Vanessa Elizabeth January 2007 (has links)
El objetivo del presente estudio in vitro fue comparar la fuerza de adhesión de una resina compuesta indirecta con diferentes tratamientos de superficie y un cemento resinoso autoadhesivo a nivel de esmalte mediante el test de microtensión. Se utilizaron 18 dientes de bovino. Se construyeron bloques de resina con moldes de nylon mediante la técnica incremental oblicua. Se dividieron en seis grupos en función al tratamiento de superficie sobre el bloque de resina polimerizada: Grupo I (grabado ácido ortofosfórico 35%), Grupo II (grabado ácido ortofsfórico 35%+ Silano), Grupo III (microarenado con AL2O3), Grupo IV (microarenado con AL2O3 + Silano), Grupo V (ningún tratamiento de superficie), Grupo VI RelyX ARC (microarenado+sistema adhesivo convencional). Después de sumergir los dientes cementados por 24 horas en agua destilada, se efectuaron los cortes milimétricos y se obtuvieron por cada grupo de trabajo 30 especímenes, los cuales fueron sometidos a la prueba de microtensión a una velocidad de 0.5 mm/min hasta producirse la falla. Los resultados se analizaron con el Test (ANOVA) y el Post Test de Tukey con el fin de determinar las diferencias significativas entre los grupos experimentales (p≤ 0.05). El Grupo V (ningún tratamiento de superficie) y Grupo III (microarenado) presentaron la mayor fuerza de adhesión (40.04 MPa) y (38.92 MPa), respectivamente, mientras que el Grupo I (grabado con ácido ortofosfórico) obtuvo el valor más bajo (32.06 MPa). El tratamiento con ácido ortofosfórico disminuye significativamente la fuerza de adhesión. Bajo las condiciones del presente estudio, la resina compuesta presenta mayor fuerza de adhesión cuando no se realiza ningún tratamiento de superficie. / -- The aim of the present study in vitro, was to evaluate the bond strength of indirect composite with different surface treatment and a self-adhesive luting cement, at enamel level, by means of the microtensile test. Eighteen bovine teeth were used and cylindrical blocks composite were constructed with nylon mol with the oblique incremental technique. They were divided into six groups according to the surface treatment on the resin block: Group I(acid orthophosphoric etching 37%) Group II(acid orthophosphoric etching 37%+ Silane), Group III (sandblasting with AL2O3), Group IV (sandblasting with AL2O3+ Silane) Group V(without surface treatment), Group VI RelyX ARC (sandblasting with AL2O3 + resin adhesive). After storing the teeth cemented by 24 hours in distilled water, the samples were sectioned perpendicular to the bonded interface to obtain thick slabs from each bonded samples. Thirty beams per group (n=30) were submitted to tensile test universal testing machine at cross-head speed of 0.5mm/min, until failure. The values in Mpa were analyzed to ANOVA and Tukey Test, to determine the significant differences between the experimental groups (p is less than0.05). Significant differences were observed in bond strength values between the group without surface treatment and sandblasting 40.04 MPa and 38.92 MPa, and those treated with acid etched 32.06 MPa. The treatment with acid orthophosphoric, diminishes the bond strength significantly. Under the conditions of the present study, the composite indirect presents greater bond strength without surface treatment.
282

Estudio comparativo in vitro de la resistencia comprensiva de resinas compuestas microhíbridas y nanohíbridas

Huayhua Revolledo, Edison David January 2013 (has links)
El propósito de este estudio fue comparar la resistencia compresiva de resinas compuestas microhíbridas y nanohíbridas. La resistencia compresiva es una propiedad mecánica importante de las resinas debido a la gran carga masticatoria que deben soportar durante la masticación, es decir que tanto puede resistir la compresión hasta su punto de fractura, por lo que lo ideal sería encontrar valores altos de compresión conforme avance la tecnología de relleno de las resinas, en la actualidad no se ha aclarado totalmente el tema debido a que si bien es cierto la mayoría de investigaciones afirma que existe relación entre el tipo de relleno de las resinas compuestas y las propiedades mecánicas no hay una clara explicación de cómo podrían estar relacionadas. El estudio es comparativo analítico y transversal. La muestra estuvo constituida por 15 cilindros de resina de cada tipo (1 de microhíbrida TPH SPECTRUM, 1 de resina microhíbrida Z250, 1 de resina nanohíbrida TPH3 y 1 de resina nanohíbrida Z250 XT) de 4 mm de diámetro por 8 mm de altura, siendo un total de 60 muestras, que luego fueron llevados a la maquina universal de ensayos marca AMSLER donde se les midió la resistencia compresiva. Los resultados se organizaron en tablas usando estadística descriptiva, hallando promedios, medianas, máximos y mínimos, además de las pruebas estadísticas T de Student y U de Mann-Whitney para comparar la resistencia compresiva entre los grupos de resina microhíbrida y entre los de resina nanohíbrida, todos con un nivel de confianza del 95%. Se concluyó que si existe diferencia significativa en la resistencia compresiva de la resina microhíbrida TPH SPECTRUM con la resina microhíbrida Z250 y con las nanohíbridas TPH3 y Z250 XT. Obteniéndose como resultado que la resistencia compresiva de la resina microhíbrida TPH SPECTRUM fue mayor que la microhibrida Z250 y las nanohíbridas TPH3 y Z250 XT, mientras que los 3 últimos grupos antes mencionados presentaron resistencia compresiva similar. -- Palabras claves: resistencia compresiva; resina compuesta microhíbrida; resina compuesta nanohíbrida. / --- The purpose of this study is to compare compressive strength and nanohíbridas microhybrid composite resins. The compressive strength is an important mechanical property of the resin due to the large load to be borne chewing during mastication, ie can withstand both compression to the point of fracture, so ideally find high compression values under technology advances filling resins, currently not fully clarified the issue because although most research states that there is a relationship between the type of filler composite resins and mechanical properties there is no clear explanation of how they might be related. The comparative analytical study is cross. The sample consisted of 15 cylinders each type resin (TPH Spectrum micro-hybrid 1, 1 Z250 microhybrid resin, resin 1 and 1 TPH3 nanohíbrida nanohíbrida resin Z250 XT) of 4 mm in diameter and 8 mm in height, being A total of 60 samples, before being taken to the universal testing machine AMSLER where they measured the compressive strength. The results are organized in tables using descriptive statistics, finding averages, medians, maximum and minimum, plus the Student t test statistics and Mann-Whitney test to compare the compressive strength between groups microhybrid resin and resin between nanohíbrida , all with a confiance level of 95%. Concluded that if there are significant differences in compressive strength resin TPH microhybrid microhybrid SPECTRUM with resin and with Z250 and Z250 TPH3 nanohíbridas XT. Obtaining as a result that the compressive strength of the TPH microhybrid resin was higher than SPECTRUM microhybrid TPH3 nanohíbridas Z250 and Z250 and XT, whereas the last 3 groups mentioned above showed compressive strength like. -- Keywords: compressive strength, micro-hybrid composite, composite nanohíbrida.
283

Análisis comparativo in vitro del grado de sellado marginal de restauraciones clase II realizadas con Surefil® SDR® Flow v/s técnica incremental convencional

Hernández Adasme, Macarena January 2013 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Se realizó un estudio comparativo “in vitro” para evaluar el grado de sellado a nivel cervical de restauraciones de resinas compuestas clase II. Para ello se utilizó una técnica incremental convencional y otra técnica de restauración recientemente propuesta, utilizando como material restaurador una nueva resina compuesta fluida, llamada Surefil® SDR® flow. Esta técnica consiste en la aplicación de un único incremento que permite hasta 4 mm de espesor en la cavidad a restaurar, dejando 2 mm hacia oclusal, donde se aplica un material de restauración convencional. Para este trabajo se utilizaron 30 molares humanos sanos, recientemente extraídos. A estos dientes se les efectuaron dos preparaciones cavitarias clase II (ocluso-mesial y ocluso-distal). En cada diente, una de las preparaciones cavitarias fue obturada con técnica convencional y la otra con la nueva técnica propuesta. Una vez efectuadas las restauraciones, estas fueron sometidas a un proceso de termociclado. Posteriormente se midió el porcentaje de microfiltración, de acuerdo a la penetración del colorante en la interfase diente-restauración en la pared cervical. Los resultados obtenidos fueron sometidos a análisis estadístico descriptivo y análisis inferencial, para verificar la existencia de diferencias estadísticamente significativas entre los grupos estudiados. Se concluye que no existen diferencias estadísticamente significativas en el porcentaje de microfiltración marginal cervical entre ambas técnicas restauradoras.
284

Estudio comparativo de la resistencia adhesiva a dentina de dos vidrios ionómeros modificados con resina in vitro

Lavandero Barrientos, Francisca January 2013 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Introducción: Dentro de los materiales de restauración se encuentran los cementos de vidrio ionómero modificados con resina, los cuales son ampliamente utilizados en la actualidad para restaurar piezas dentales, ya que presentan una unión a los tejidos dentarios predecible en el tiempo, una buena estética y una alta liberación de flúor. En este estudio se evaluó la resistencia adhesiva de dos tipos de cementos de vidrio ionómero modificados con resina: Fuji II LC® (GC corp., Alsip, IL, USA) que es un ionómero híbrido de fotocurado comúnmente utilizado en Chile que se encuentra en una presentación tradicional polvo-líquido y Geristore® (DenMat corp., Santa María, CA,USA), un vidrio ionómero modificado con resina de curado dual que pretende introducirse al mercado chileno con una nueva presentación pasta-pasta de automezcla, dejando atrás la habitual presentación polvo-líquido. Dado que se trata de un material de reciente aparición en Chile y con una nueva presentación, el presente estudio buscó evaluar su grado de adhesión a dentina comparándolo con un material presentación polvo-líquido y de amplio uso de en el país como Fuji II LC®. Materiales y métodos: 20 terceros molares sanos fueron seccionados para obtener 40 mitades, mesiales y distales. Un cilindro de Fuji II LC® se construyó sobre el segmento mesial y de Geristore®, sobre el segmento distal de cada molar seccionado, formado así dos grupos de 20 muestras cada uno. Los cuerpos de prueba se sometieron a una fuerza de cizallamiento en la máquina de ensayos universal, Marca Tinius Olsen®, Modelo H5K-S para determinar el grado de resistencia adhesiva a dentina que lograron ambos materiales. Resultados: Los datos obtenidos se sometieron a análisis estadístico. Mediante el Test de Kolmogorov – Smirnov se demostró la distribución normal de los datos, para posteriormente analizarlos con Test T, con lo cual se determinó que no existen diferencias significativas entre ambos grupos. Conclusión: Se concluye que no existen diferencias significativas en la resistencia adhesiva a dentina de Fuji II LC® y Geristore®.
285

Estudio comparativo in vitro de la profundidad de polimerización de resina compuesta fluida con lámpara L.E.D, al interponer bloques de resina compuesta indirecta de diferentes valores de colro

Alvarado Duarte, Daniela Constanza January 2014 (has links)
Trabajo de Investigación Requisito para optar al Título de Cirujano Dentista / Para cementar restauraciones estéticas se indican los cementos a base de resina, los cuales dependiendo del mecanismo de activación se clasifican en cementos de autocurado, de fotocurado y de curado dual. Principalmente se prefieren los cementos de fotocurado debido a su mayor estabilidad del color en el tiempo, sin embargo, su uso se encuentra limitado a situaciones clínicas donde el grosor y color de la restauración no afecten el paso de la luz (Caughman y cols, 2001; Manso y cols, 2011; Stamatacos y Simon, 2013). Es por lo previamente señalado, que este estudio consistió en determinar la influencia del color de la restauración, específicamente el valor del color, en la profundidad de polimerización del medio cementante En un estudio in vitro se comparó la profundidad de polimerización de una resina compuesta fluida al ser fotopolimerizada a través de bloques de resina compuesta indirecta Artglass® de distintos valores de color. Para lo cual se confeccionaron 3 especímenes de 4mm de alto y 8mm de diámetro en distintos colores; 0M1, 2M1 y 5M1. En formadores metálicos cilíndricos de 4mm de alto y 6mm de diámetro se depositó resina fluida hasta enrasar en superficie, y posteriormente se iluminó con una lámpara L.E.D por un tiempo de 60 segundos interponiendo los distintos especímenes entre la luz y la resina fluida. También se polimerizó resina fluida directamente por 60 segundos como grupo control. Para cada grupo se confeccionaron 20 muestras y 8 muestras para el grupo control, arrojando un total de 68 muestras, las cuales fueron medidas con un pie de metro con una sensibilidad de 0,1mm. Los resultados fueron sometidos a análisis estadísticos descriptivos y comparados mediante la prueba no paramétrica de Kruskal-Wallis arrojando diferencias estadísticas entre los grupos (p ˂0,05) Se concluyó que al aumentar el valor del color de la resina indirecta interpuesta disminuye la profundidad de polimerización de la resina fluida. Aun así, se 5 determinó que es posible utilizar resinas compuestas fluidas para la cementación de una restauración de Artglass® de 4mm de grosor independiente del valor del color de esta, ya que la profundidad de polimerización obtenida en todos los grupos estudiados fue mayor que el grosor establecido por la norma ISO 4049 (2009) para la interfase diente restauración para este tipo de materiales.
286

Influência da fonte de luz fotoativadora na resistência de união e na micromorfologia da interface adesiva de restaurações de resina composta - Um estudo 'in vitro' com microscopia de fluorescência / Influence of light-curing sources on bond strength and on interfacial micromorphology of resin composite restorations – a fluorescence microscopy study

D'Alpino, Paulo Henrique Perlatti 07 April 2005 (has links)
Propôs-se avaliar a influência de diferentes fontes de luz fotoativadoras na micromorfologia e na resistência de união adesiva de restaurações de resina composta. Selecionaram-se terceiros molares hígidos que receberam preparos cavitários classe I (6,0 mm x 4,5 mm; 2,5 mm profundidade). A resina composta (Filtek Z250 - RC) foi inserida em incremento único após a aplicação e polimerização do sistema adesivo (Adper Single Bond - SB). Os materiais restauradores foram fotoativados com os seguintes aparelhos: XL 3000 (QTH: 540 mW/cm2); Elipar FreeLight 2 (LED: 750 mW/cm2) e Arc Light IIM (PAC: 2.130 mW/cm2). Nove grupos experimentais foram avaliados de acordo com as combinações de fonte de luz para fotoativar SB/RC: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Para a análise da micromorfologia foi utilizada microscopia de fluorescência (Laser de Fóton Duplo), sendo que um corante fluorescente vermelho (Rodamina B) foi adicionado ao sistema adesivo. Além disso, utilizou-se uma solução de corante fluorescente verde (Dextran- Fluoresceína), que foi aplicada na câmara pulpar durante 4 horas, para que se difundisse em direção à interface. Os dentes foram então lavados, incluídos, seccionados e analisados microscopicamente. Os parâmetros analisados foram: espessura da camada de adesivo, espessura e qualidade da camada híbrida, micropermeabilidade, qualidade e habilidade de selamento dos tags de resina e, ainda, localização e extensão de fendas. Para o teste de resistência adesiva, os dentes foram restaurados, de acordo com as combinações de fonte de luz, e armazenados por 24 horas a 37 °C. Em seguida os dentes foram seccionados e submetidos ao teste de microtração. Realizou-se ainda a análise dos parâmetros de cinética de conversão de monômeros (conversão total, taxa máxima de conversão, conversão na máxima taxa, tempo em que ocorreu a máxima taxa e relação conversão na máxima taxa/conversão total) em um espectrofotômetro de raios infravermelho, ao qual foram aplicados os mesmos materiais restauradores que foram polimerizados com as diferentes fontes de luz. Para as avaliações qualitativas foi realizado o teste estatístico Kruskal-Wallis e o teste de Dunnet para comparações múltiplas (&#945; = 0,05). Para as avaliações quantitativas foi realizada análise de variância e teste de Tukey para comparações múltiplas (&#945; = 0,05). Da análise dos resultados, observou-se que as fontes de luz utilizadas influenciaram nos parâmetros de cinética de conversão de monômeros. De forma geral, ocorreu uma relação inversa entre a conversão total e a densidade de potência quando se polimerizou o sistema adesivo. Na resina composta base, houve uma relação direta. Para ambos os materiais houve uma maior taxa máxima de conversão, em um menor tempo, proporcional à densidade de potência dos aparelhos. Quanto aos parâmetros de micromorfologia, não se observou diferença siginificante entre os grupos experimentais em relação à espessura e qualidade de camada híbrida. Em relação à espessura da camada de adesivo, observaram-se maiores espessuras quando o sistema adesivo foi polimerizado com o PAC. Para a micropermeabilidade, também não se observou diferença entre os grupos. Também, não se observou diferença siginificante em relação à qualidade e habilidade de selamento dos tags de resina. Em relação à presença de fendas, quando o PAC polimerizou o sistema adesivo, menores porcentagens de piores escores e menores extensões de fendas foram observadas. A combinação PAC/QTH apresentou valores significantemente maiores de resistência adesiva e LED/QTH, as menores. A espessura da camada de adesivo, localização de fendas e resistência adesiva foram significantemente influenciados pela fonte de luz que polimerizou o sistema adesivo, sendo que, quando o PAC foi utilizado, melhores resultados foram observados. As combinações de mesma fonte de luz apresentaram, de forma geral, resultados similares. As diferentes fontes de luz fotoativadoras influenciam na resistência de união adesiva e em alguns parâmetros da micromorfologia da interface de restaurações de resina composta. / The purpose of the present in vitro study was to evaluate the effect of different light-curing sources on interfacial micromorphology and on bond strength of resin composite restorations. Class I preparations (6.0 mm long, 4.5 mm wide, 2.5 mm deep) were made in extracted human third molars, after abrading cusps, following university approved HAC guidelines. Restorations were placed in bulk, using a dentin bonding agent (DBA) / resin composite (RC): Adper Single Bond / Filtek Z250. Restoratives were light-cured as follows: XL 3000 (QTH: 540 mW/cm2); Elipar FreeLight2 (LED: 750 mW/cm2); Arc Light II (PAC: 2,130 mW/cm2). Nine experimental groups were developed from the different light combinations with respect to curing the DBA/COMP: QTH/QTH; QTH/LED; QTH/PAC; LED/LED; LED/QTH; LED/PAC; PAC/PAC; PAC/QTH; PAC/LED. Fluorescing agent (Rhodamine B) was added to the DBA, highlighting the bonded interface and surrounding structures. A different colored dye (FTIC-Dextran) was placed in the pulp chamber for 3 hours, allowing time to diffuse toward the different-colored interface. The teeth were then embedded, sectioned, and microscopically analyzed using fluorescence microscopy (Two-Photon Laser) at 40x magnification. Micromorphology quantitative and qualitative evaluations were: quality and thickness of hybrid layer; micropermeability test, adhesive layer thickness; quality and sealing ability of resin tags; location and extension of gaps. For bond strength test, the same experimental groups were obtained. After restorative procedures, the teeth were stored in distilled water for 24 h at 37 °C. After this time period, resin layers were added to the restoration surface (providing same dentin/resin length), and then sectioned and subjected to microtensile test in a universal testing machine. Kinetics conversion parameters were also evaluated in an FT-IR spectrophotometer (total conversion, maximum rate of cure, time when maximum rate occurred, conversion at maximum rate, conversion at maximum rate/ total conversion ratio). The same restorative materials were applied to the ATR device, attached to the spectrophotometer, and then polymerized according to manufacturer’s instructions. Data was statistically analyzed as mentioned below. Statistical analyses revealed that different light sources influenced the kinetics conversion (one-way ANOVA, p< 0,05). It was found an inverse relation between power density and monomer conversion when polymerizing DBA. For resin composite (bottom), there was a positive relation between power density and total conversion. High intensity, broad banded PAC light produced higher maximum rate of cure (in %/s), in shorter times. In terms of micromorphology, no significant difference was found in terms of quality and thickness of hybrid layer (two-way ANOVA, p> 0.05). No significant difference was noted for in quality and in sealing ability of tags (Kruskal Wallis, p> 0.05). QTH/QTH presented higher percentages of best scores for both parameters. Adhesive layers were found to be significantly thicker when PAC light was used to polymerize DBA. Even thought it was also found no significance in micropermeability scores (Kruskal Wallis, p> 0.05), it was found higher percentage of best scores for control QTH/QTH. Photo-polymerizing DBA using PAC produced lower incidence of gap formation, irrespective of RC curing source. Combination PAC/QTH presented significantly higher bond strength and LED/QTH, the lower (two-way ANOVA, Dunnet’s pos-hoc test, p< 0.05). Part of interfacial micromorphology parameters and bond strength were more dependent on the photo-polymerization source used for dentin-bonding agent than for resin composite. Photo- polymerizing DBA using PAC produced best results for adhesive thickness, gap location, and bond strength. Although QTH/QTH, LED/LED, and PAC/PAC combinations produced similar general results, it was found inherent characteristics when analysing tested parameters. Different light curing units influence bond strength and some parameters of micromorphology.
287

Efeito de diferentes tratamentos de superfície na resistência de união adesiva em resina composta contaminada por saliva / EFFECT OF DIFFERENT SURFACE TREATMENTS IN SHEAR BOND STRENGTH OF COMPOSITE RESIN CONTAMINATED BY SALIVA

Furuse, Adilson Yoshio 03 June 2005 (has links)
Avaliou-se a resistência adesiva ao cisalhamento de uma resina composta contaminada por saliva, com adição de novo incremento do mesmo material. 40 corpos-de-prova de uma resina composta nano-híbrida, confeccionados em uma matriz de resina epóxica, foram divididos em quatro grupos, cada um recebendo um tratamento de superfície. Em um dos grupos, a superfície não foi contaminada (Grupo 1 - controle). Para a confecção do segundo segmento do corpo-de-prova, utilizou-se uma matriz de Teflon de 3,5mm de diâmetro por 3,0mm de altura. Nos demais grupos, a superfície da resina composta foi contaminada com saliva e seca com ar comprimido, sendo os tratamentos estabelecidos da seguinte forma: Grupo 2 - resina composta inserida e polimerizada sobre a superfície contaminada; Grupo 3 - condicionamento com ácido fosfórico a 35%, aplicação de adesivo e inserção de resina composta; Grupo 4 - asperização com ponta diamantada, condicionamento com ácido fosfórico a 35%, aplicação de adesivo e inserção de resina composta. Após a confecção, os espécimes foram armazenados em água a 37oC durante 24h, sendo em seguida montados em uma máquina universal de ensaios para realização dos testes de resistência ao cisalhamento. Os resultados foram submetidos à análise de variância a um critério e ao teste de Tukey para comparação entre os grupos. Não houve diferença entre os grupos 3, 4 e controle (p < 0,05). A contaminação da superfície da resina com saliva (Grupo 2) diminuiu significativamente a resistência de união (p < 0,05). A análise em MEV dos espécimes do grupo 2 demonstrou a ocorrência de fraturas na interface adesiva em quase todos os corpos-de-prova (80%). Fraturas coesivas da resina inserida na matriz de resina epóxica puderam ser observadas em todos os espécimes dos Grupos 3 e 4. O método que emprega limpeza superficial com ácido e aplicação de um sistema adesivo demonstrou ser efetivo na recuperação da resistência adesiva a valores semelhantes à resistência coesiva do material / Shear bond strength between the contaminated composite resin surface and a new increment of the same material was analysed. Forty specimens of a nanohybrid composite, were divided into four groups. Each group received a surface treatment. In one of the groups, there was no surface contamination (Group 1 - control). The new increment of composite resin was inserted by placing a Teflon matrix (3.5mm height, 3mm diameter) over the already polymerized composite surface. For the other groups, the polymerized composite surface was contaminated with saliva and dried with air. Surface treatments were performed in the following way: Group 2 - new increment was inserted and polymerized directly on the contaminated surface; Group 3 - contaminated surface was treated with 35% phosphoric acid etching and adhesive was applied prior to the insertion of the new increment; Group 4 - diamond bur roughening, 35% phosphoric acid etching, adhesive application and insertion of the new composite increment. Specimens were stored in water at 37oC for 24h. After this period, specimens were mounted in a universal testing machine for the shear bond strength tests. Results were submitted to one way anova and Tukey test multiple comparison. No significant differences were detected between Groups 3, 4 and control (p < 0.05). Saliva contamination of resin surface (Group 2) significantly reduced shear bond strength (p < 0.05). SEM analysis in Group 2 demonstrated fractures at the interface in 80% of the specimens. Cohesive fractures in first increment of resin composite was observed in all specimens in Groups 3 and 4. Decontamination of resin surface with phosphoric acid followed by adhesive application, was an effective method to improve shear strength, reaching similar numbers to the cohesive resistance of the material
288

Efeito da desinfecção química sobre a microdureza e rugosidade superficial de resinas para base de dentaduras e resinas rígidas para reebasamento: estudo longitudinal / Effect of chemical disinfection on the hardness and roughness of denture base resins and hard chairside resins: a longitudinal study

Pinto, Luciana de Rezende 20 April 2007 (has links)
O objetivo deste estudo foi investigar, longitudinalmente, o efeito de cinco soluções desinfetantes sobre a microdureza e rugosidade superficial de uma resina acrílica termopolimerizável e três materiais reembasadores rígidos. Um total de 240 corpos de prova circulares (30 X 6mm) foram fabricados, utilizando um material para base de dentaduras (Lucitone 550; n=60), e três materiais rígidos, para reembasamento (Jet; n=60, Kooliner; n=60, Tokuyama rebase II fast; n=60), os quais foram imersos em água (controle), e em cinco soluções desinfetantes (hipoclorito de sódio a 1%, hipoclorito de sódio a 2%, hipoclorito de sódio a 5,25%, glutaraldeído a 2% e gluconato de clorexidina a 4%), e testados para avaliação de microdureza Knoop (KHN) e rugosidade superficial (Ra-µm) em diferentes intervalos (antes das imersões, após 30, 90 e 180 ciclos de desinfecção. Em cada condição experimental foram utilizados 10 corpos de prova de cada material estudado. Os dados foram analisados através de esquema fatorial (6X4) e as médias foram analisadas por meio de análise de variância, seguida por teste de Tukey a 5%. Para as resinas Lucitone 550 (20,61 ± 1,36 a 15,44 ± 1,26 KHN), Jet (18,74 ± 0,47 a 13,75 ± 0,95 KNH), Kooliner (14,09 ± 1,63 a 7,52 ± 0,88 KHN) e Tokuyama rebase II fast (12,57 ± 0,94 a 8,28 ± 0,39 KHN), foi observada uma diminuição significativa dos valores de microdureza, independente da solução utilizada, após 180 ciclos de imersão. Não foi observada interação significativa para a rugosidade da resina Kooliner. Para a resina Lucitone 550 (0,06 ± 0,01 a 0,20 ± 0,02µm) e Jet (0,07 ± 0,01 a 0,23 ± 0,04µm), foi observado aumento significativo dos valores de rugosidade superficial, independente da solução desinfetante utilizada, e a após 180 ciclos de imersão em água, estes materiais mantiveram valores semelhantes ao da avaliação inicial. A resina Tokuyama rebase II fast não mostrou diferenças significativas nos valores de rugosidade superficial quando imersa em água, hipoclorito de sódio a 2%, 5,25% e glutaraldeído a 2%, durante o período do estudo. Ao final da avaliação (180 ciclos), conclui-se que, embora todas as soluções tenham causado redução da microdureza da resina Lucitone 550, os espécimes submetidos às imersões em H5,25% e H2% apresentaram menores valores, no entanto, não ocorreu diferença significante entre os desinfetantes para as resinas autopolimerizáveis. As soluções H1%, H2% e GC4% causaram maior alteração na rugosidade superficial da resina Lucitone 550. Estas mesmas soluções, além de H5,25%, promoveram maior rugosidade na resina Jet, enquanto que, para a resina Tokuyama Rebase II fast, não houve diferença entre os desinfetantes. / The aim of this study was to investigate the longitudinal effect of five disinfection solutions on the hardness and roughness of one heat-polymerizing denture base acrylic resin and three hard chairside resins. A total of 240 circular specimens (30 X 6mm) were fabricated using one denture base material (Lucitone 550; n=60) and three hard chairside reliners (Jet; n=60, Kooliner; n=60, Tokuyama rebase II fast; n=60), which were immersed in water (control), and five disinfecting solutions (1% sodium hypochlorite; 2% sodium hypochlorite; 5,25% sodium hypochlorite, 2% glutaraldehyde; 4% chlorhexidine gluconate) that were tested for knoop hardness (KHN) and roughness (Ra-µm) for different times (before immersions, after 30, 90 and 180 immersion cycles). For each experimental condition, 10 specimens were used from each material. Data was analyzed by factorial scheme (6 X 4) and the means were analyzed by The Variance Analysis which was followed by Tukey\'s test 5%. For Lucitone 550 (from 20,61 ± 1,36 to 15,44 ± 1,26 KHN), Jet (from 18,74 ± 0,47 to 13,75 ± 0,95 KHN), Kooliner (from 14,09 ± 1,63 to 7,52 ± 0,88 KHN), Tokuyama rebase II fast (from 12,57 ± 0,94 to 8,28 ± 0,39 KHN) significant decrease in hardness was observed regardless of the solution used, after 180 immersion cycles. No significant interactions were observed for Kooliner roughness. Between Lucitone (from 0,06 ± 0,01 to 0,20 ± 0,02µm) and Jet, (from 0,07 ± 0,01 to 0,23 ± 0,04µm) there was a significant increase in roughness regardless of the disinfectant solution used; Jet showed significant increase in roughness after immersion in water for 180 cycles. Tokuyama rebase II fast showed no significant differences in roughness when immersed in water, 2% sodium hypochlorite, 5.25% sodium hypochlorite, and 2% glutaraldehyde after 180 cycles. In conclusion, this study showed that Lucitone 550 specimens exhibited significant decrease in hardness regardless of the disinfection solution used, and the specimens immersed in H5,25% and H2% showed lower hardness values; However, no significant differences were noted between all disinfectants solution, for hard chairside resins. The solutions H1%, H2% and GC4% caused more alteration in roughness of Lucitone 550. These solutions along with H5,25% caused an increase in the roughness of Jet, while with the Tokuyama rebase II fast there was no difference between the disinfection solutions.
289

Efeito de sucessivos ciclos de desinfecção por microondas sobre a microdureza e rugosidade superficial de diferentes bases de próteses totais: estudo longitudinal / Effect of successive microwave disinfection cycles on the hardness and roughness of different denture base resins: a longitudinal study

Távora, Flora Freitas Fernandes 22 June 2007 (has links)
O objetivo desse estudo foi investigar longitudinalmente, o efeito de sucessivos ciclos de desinfecção sobre as propriedades de microdureza e rugosidade superficial de 4 diferentes resinas acrílicas. Foram confeccionados 200 corpos de prova, utilizando um material para base de dentaduras (Lucitone 550) e três materiais rígidos para reembasamento (Jet, Kooliner e Tokuyama Rebase II Fast), os quais foram divididos, para cada resina, em cinco grupos: imersos em água (controle) e submetidos à irradiação por microondas em quatro combinações diferentes de potência-tempo. Esses grupos foram avaliados em relação à rugosidade superficial (Ra-µm) e microdureza Knoop (KHN) em um período anterior às desinfecções e após 30, 90 e 180 ciclos de desinfecção. Os dados foram submetidos à análise de variância, seguida por teste de Tukey a 5%. As principais alterações nos valores de microdureza (diminuição) e rugosidade superficial (aumento) ocorreram após 30 ciclos de desinfecção em microondas. Após esse período existiu uma tendência para a estabilização dos valores dessas propriedades, mesmo quando ciclos adicionais (90 e 180 ciclos) foram realizados. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) não foram os principais fatores que tiveram influência sobre a propriedade de microdureza. É provável que a redução dos valores de microdureza tenha sido mais dependente da sorpção de água do que da energia de microondas por si só. O principal efeito sobre a microdureza através da irradiação por microondas parece ser o efeito da água. A exposição da prótese a fluidos como água e saliva é uma condição que não pode ser evitada. Esse comportamento não foi observado para a rugosidade superficial. Os tratamentos empregados para os diferentes grupos experimentais (diferentes combinações de potência-tempo) tiveram influência sobre a propriedade de rugosidade superficial. De maneira geral observou-se que os valores de rugosidade superficial dos espécimes somente imersos em água foram menores do que os valores dos espécimes irradiados. Apesar da rugosidade de alguns espécimes ter ficado acima de 0.2 um, isso não parece contra-indicar a desinfecção por microondas. As técnicas convencionais de acabamento e polimento aplicadas para as outras superfícies dificilmente atingem níveis de rugosidade superficial inferiores a 0,2 µm. Dessa maneira parece ser prudente a afirmação de que a desinfecção através da energia de microondas pode ser utilizada para a desinfecção de próteses. / The objective of this study was to investigate the longitudinal effect of microwave disinfection on the hardness and roughness of one heat-polymerizing denture base acrylic resin and three hard chairside resins. A total of 200 specimens were fabricated using one denture base material (Lucitone 550; n=50) and three hard chairside reliners (Jet; n=50, Kooliner; n=50, Tokuyama Rebase II Fast; n=50), which were immersed in water (control), and submitted to microwave disinfection at four different arrangements of power and time. These specimens were tested for knoop hardness (KHN) and roughness (Ra-µm) for different times (before disinfection, after 30, 90 and 180 disinfection cycles). Data were analyzed by Variance Analysis which was followed by the Turkey\'s test at a level of 5%. The principal alterations on hardness (reduction) and on roughness (elevation) occurred after 30 disinfection cycles. Both of the properties remained stable after this period, even after 90 and 180 disinfection cycles. The different arrangements of power and time carried out for the experimental groups did not have influence on hardness. It is possible that this property was more affected from water sorption than microwave energy only. During its clinical use, the denture is exposed to water and saliva and it seems that this condition cannot be prevented. This fact was not observed for roughness. The different arrangements of power and time carried out for the experimental groups had influence on roughness. It was observed that the control group had lower roughness values when compared to the experimental groups. The roughness values of some specimens were greater than 0.2 um. However, this fact does not compromise the indication of microwave disinfection. The finishing and polishing techniques commonly used for the other surfaces of the denture do not get roughness values below 0.2 um. Therefore, it is very likely that microwave disinfection could be recommended for the disinfection of dentures.
290

Resistência à tração diametral de uma resina composta associada a pinos intra-radiculares pré-fabricados. / Diametral tensile strength of a resin composite core bonded to prefabricated posts.

Santos Júnior, Gildo Coelho 10 March 2003 (has links)
Este estudo teve a finalidade de verificar influência de diferentes tipos de pinos intra-radiculares sobre a resistência à fratura de um material restaurador coronário, utilizando o teste de tração diametral. Foram confeccionados 70 corpos de prova divididos em 7 grupos: G1. Compósito (Tetric Ceram – Ivoclar/Vivadent) (Grupo Controle); G2. Compósito e pino VectrisPost (Ivoclar/Vivadent); G3. Compósito e pino Fiber-Post (Jeneric/Pentron); G4. Compósito e pino Æstheti-Plus (Bisco); G5. Compósito e pino Light-Post (Bisco); G6. Compósito e pino Dentorama (Svenska) e G7. Compósito e pino ParaPost (Còltene/Whaledent). Todos os grupos foram submetidos ao ensaio de tração diametral em uma máquina de ensaios Instron, modelo 8501, até a fratura. A média dos grupos em MPa foi: G 1- 49,64 (3,36); G 2- 29,77 (3,36); G 3- 31,9 (2,39); G 4- 28,92 (2,20); G 5- 34,26 (3,37); G 6-33,45 (2,46) e G 7- 27,90 (2,40). A análise estatística dos dados nos permitiu concluir que: os pinos utilizados não reforçaram a resina composta; os pinos Light-Post, Dentorama e Fiber-Post apresentaram os melhores valores de adesividade ao material de reconstrução coronária e que o pino metálico ParaPost apresentou o menor valor de adesão à resina de reconstrução coronal. / The purpose of this study was to determine the influence of different types of posts on the fracture strength of a resin composite core material using the diametral tensile strength test. Seven groups of specimens were prepared each with 10 cylindrical specimens made of one composite material (Tetric Ceram, IvoclarVivadent) as follows: Group 1- Control group of composite only specimens; Group 2-Composite and VectrisPost (IvoclarVivadent); Group 3- Composite and Fiber-Post (Jeneric/Pentron); Group 4- Composite and Æstheti-Plus post (Bisco); Group 5- Composite and Light-Post (Bisco); Group 6- Composite and Dentorama post (Svenska) and group 7- Composite and ParaPost (Coltene/Whaledent). Following storage specimens were subjected to compressive loading in an Instron testing machine (model 8501) until failure occurred. Means and standard deviations of diametral tensile strengths in MPa were: Group 1- 49,64 (3,36); Group 2- 29,77 (3,36); Group 3- 31,9 (2,39); Group 4- 28,92 (2,20); Group 5- 34,26 (3,37); Group 6- 33,45 (2,46) and Group 7- 27,90 (2,40). Statistical analysis revealed significant differences in mean diametral tensile strengths among the groups. It is concluded that the use of posts did not reinforce the composite resin cores. Among the post/core groups Light-Post, Dentorama post and Fiber-Post resulted in the highest values of tensile strength while ParaPost resulted in the lowest value of tensile strength.

Page generated in 0.0301 seconds