• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 119
  • 71
  • 65
  • 44
  • 43
  • 32
  • 30
  • 25
  • 24
  • 24
  • 22
  • 21
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Aplicação de ondas de ultra-som sobre cimentos de ionômero de vidro: rugosidade superficial e perda de massa após ensaio de escovação

Coldebella, Cármen Regina [UNESP] 30 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-30Bitstream added on 2014-06-13T18:31:57Z : No. of bitstreams: 1 coldebella_cr_me_arafo.pdf: 1675435 bytes, checksum: d701cec4b032faaeb9271b9401f5dc6d (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Este trabalho teve como objetivo determinar a influência da excitação ultra-sônica aplicada em dois cimentos de ionômero de vidro nos momentos inicias de sua reação de presa, avaliando a rugosidade superficial e a perda de massa após ensaio de escovação. Os materiais foram o Fuji IX GP (GC Corporation) e Ketac Molar Easymix (3M ESPE), manipulados de acordo com as instruções dos fabricantes e inseridos em matriz confeccionada com dente bovino. Foram confeccionados 16 espécimes de cada material, dos quais a metade recebeu excitação com ondas de ultra-som (PROFI III BIOS - Dabi Atlante) por um período de 30 segundos. Todos os corpos foram pesados diariamente, em balança analítica (Sartoruis), até a estabilização de sua massa, a qual foi alcançada após 20 dias da manipulação. Logo após foi realizada a leitura da rugosidade inicial (rugosímetro Surfcorder SE 1700 - Japão). Em seguida os mesmos foram submetidos ao ensaio de escovação, totalizando 30.000 ciclos. Nova leitura de rugosidade superficial e seqüência de pesagem foram realizadas. Para a análise estatística foram utilizados os testes de Análise de Variância (MANOVA) e t-Student onde a diferença estatística foi determinada por p= 0,05. Observou-se diferença estatística significante na rugosidade superficial antes e após o ensaio de escovação (p= 0,00). Porém não houve diferença estatística na rugosidade quando considerada a aplicação de ondas de ultra-som (p= 0,06). A média de rugosidade após ensaio de escovação para o Fuji IX GP foi de 0,767æm e 0,643æm com e sem a aplicação de ondas de ultra-som respectivamente e para o Ketac Molar Easymix esses valores foram de 0,759æm e 0,757æm para as mesmas condições experimentais. Na interação material, excitação ultra-sônica e ensaio de escovação foi observada diferença... Resumo completo, clicar acesso eletrônico abaixo) / The aim of this work was to determine the influence of ultrasonic excitation in two glass ionomer cements (GICs) evaluating the superficial roughness and mass loss after toothbrushing test. The GICs tested were Fuji IX GP (GC Corporation) and Ketac Molar Easymix (3M ESPE). The cements were manipulated according to the manufacturesþ instructions and inserted in a bovine tooth matrix. For each material 16 specimens were made. Eight specimens of them were excited with ultrasonic waves (PROFI III BIOS - Dabi Atlante) for 30s. All specimens were weighed daily in an analytical balance (Sartoruis) until their mass stabilization which was reached after twenty days. Next, the initial superficial roughness reading was performed (Surfcorder SE 1700 - Japan). After that, toothbrushing test was performed, and 30.000 cycles were applied. Soon after, a new superficial roughness reading and a sequence of weighing were performed. The statistical analysis was made through MANOVA test and t-Student where p= 0.05 determined a significant statistical difference. A difference on the superficial roughness was observed before and after toothbrushing (p=0.00). However, there was no statistical difference when the ultrasonic waves were used (p=0.06). After toothbrushing test Fuji IX GP roughness average was 0.767æm and 0.643æm with and without the use of ultrasound waves respectively while Ketac Molar Easymix showed 0.759æm and 0.757æm in the same experimental conditions. In the interaction: material, ultrasonic excitation, and toothbrushing test, a significant statistical difference was observed (p=0.004) which was due to the toothbrushing test and not to the use of ultrasonic waves. The mean of weigh loss was 0.45mg for Fuji IX GP with ultrasound excitation, and 0.61mg without this procedure; Ketac Molar Easymix showed 0.27mg and 0.16mg respectively. However, there was no statistica... (Complete abstract, click electronic access below)
82

Resistência à fratura de dentes com preparos cavitários MOD restaurados com resina composta e fibra de vidro

Rodrigues, Fausto Borges January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2 000392253-0.pdf: 813004 bytes, checksum: 92cc239906e68f814913bc5491cecb54 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate in vitro the effect of two types of glass fibers, unidirectional or woven, placed inside of MOD cavity preparations on fracture strength of endodontically treated molars, either restored with composite resin, or not. Ninety sound human third molars were extracted, embedded in acrylic resin blocks and randomly assigned to six groups (n=15). Group 1 G1 (sound teeth), control. Groups G2, G3, G4, G5 e G6 were subjected to the following procedures: G2 – MOD cavity preparation; G3 – MOD and endodontic treatment (ET); G4 –MOD + ET + composite resin restoration (CR); G5 – MOD + ET + unidirectional fiber (UF) + CR; G6 - MOD + ET + woven fiber (WF) + CR. The specimens were stored in physiological serum at 37oC for 24 hours. Later, a compressive force was applied by means of a universal testing machine at 1 mm/min speed, parallel to the long axis of the teeth until the fracture occurred. After mechanical test three types of fractures were classified: 1) pulp chamber floor; 2) cusp; 3) pulp chamber floor and cusp. The means of results (N) followed by the same letter do not represent a statistical difference by ANOVA and Tukey (p<0,05): G1 (4960)a, G2 (1926. 20)b, G3 (612. 84)c, G4(1813. 9)b, G5 (2024)b, G6 (1879)b. In the analysis of qualitative variables of G5 and G6, there was a tendency to fracture in the pulp chamber floor and cusp not benefic to restore the tooth integrity. It is possible conclude that inserting the unidirectional or woven glass fibers into MOD cavity preparations and restored with composite resin the fracture strength is similar to that obtained in molars filled with composite resin only. / A proposta deste estudo foi avaliar o efeito de dois tipos de fibras, uma trançada e outra unidirecional, inseridas no interior de cavidades MOD padronizadas na resistência à fratura de dentes molares tratados endodonticamente. Noventa dentes terceiros molares hígidos foram selecionados e montados em blocos acrílicos, sendo estes divididos em seis grupos de quinze (n=15). No grupo G1, os dentes mantiveram-se hígidos (controle). Os grupos G2, G3, G4, G5 e G6 receberam preparos cavitários MOD padronizados, sendo que nos grupos G3, G4, G5 e G6 foram realizados tratamentos endodônticos. Após o preparo dos dentes, estes foram restaurados com resina composta, no grupo G4, e no grupo G5 e G6 foram inseridas dois tipos de fibras, uma trançada e outra unidirecional, respectivamente. Após, os corpos de prova foram submetidos ao ensaio de resistência à fratura. Avaliou-se, também, qualitativamente as falhas classificando-as em fratura de cúspide, assoalho e cúspide mais assoalho, após o ensaio mecânico. Os resultados (N) obtidos foram (médias seguidas de mesma letra não apresentam diferença estatística para Anova e Tukey (p<0,05): Grupo G1 (4960)a, Grupo G2 (1926,20)b, Grupo G3 (612,84)c, Grupo G4 (1813,9)b, Grupo G5 (2024)b, Grupo G6 (1879)b. Conclui-se que a utilização de fibras trançadas ou unidirecionais no interior de cavidades MOD de dentes com tratamento endodôntico não melhora a resistência a compressão apresentando um padrão de fratura de assoalho mais cúspide não favorável à recuperação da peça dentária.
83

Avaliação clínica e laboratorial de resina composta em função da fotoativação com diferentes fontes de luz e densidades de potência / Clinical and laboratorial evaluation of resin composite light-cured with different curing units and power densities

Ana Raquel Benetti 27 July 2007 (has links)
O objetivo deste estudo foi avaliar o desempenho clínico e laboratorial de uma resina composta, considerando diferentes fontes de luz e densidades de potência, mantendo-se padronizada a densidade total de energia. O grau de conversão da resina composta foi determinado através de espectroscopia por transformada de Fourier. O grau de amolecimento em etanol foi obtido pela determinação da dureza Wallace, antes e após o armazenamento da resina composta em etanol a 75%. O desgaste foi mensurado por dois métodos: o teste da ACTA e o teste de escovação simulada. Paralelamente, investigou-se o desempenho clínico de restaurações de resina composta em dentes posteriores, submetidas aos mesmos protocolos de fotoativação. Restaurações de classe I de resina composta foram confeccionadas e fotoativadas por lâmpada de quartzo-tungstênio ou diodo emissor de luz a 300 mW/cm2, durante 40 segundos, ou a 600 mW/cm2, durante 20 segundos. As restaurações foram avaliadas, imediatamente e após 6 e 12 meses, por dois examinadores calibrados, de acordo com os critérios modificados de Ryge. Os dados laboratoriais foram submetidos à análise de variância a dois critérios e teste de comparações múltiplas de Newman-Keuls, ou ao teste t-pareado. Os dados clínicos foram analisados pelos testes Kappa, Fisher e McNemar (\'alfa\' = 0,05). Não foram constatadas diferenças significantes quanto aos diferentes protocolos no grau de conversão, no grau de amolecimento em etanol e no desgaste produzido pelo método da ACTA (p > 0,05). Para o teste de desgaste por escovação simulada, a fotoativação com diodos emissores de luz a 300 mW/cm2, durante 40 segundos, resultou em maior desgaste que os demais protocolos testados (p < 0,05). Adicionalmente, não foram observadas diferenças significantes quanto aos diferentes protocolos de fotoativação no desempenho clínico das restaurações, ao final de um ano de avaliação (p > 0,05) / The aim of this study was to evaluate the clinical and laboratorial performance of a resin composite light-cured with different light-curing units and power densities, at a standard energy density level. Degree of conversion of the resin composite was determined by Fourier transformed infrared spectroscopy. The degree of softening of the resin composite in ethanol was obtained by Wallace hardness measurements before and after storage in a 75% ethanol solution. Wear of the resin composite was acquired by two methods: ACTA wear and toothbrush abrasion. Additionally, the clinical performance of resin composite restorations submitted to the same light-curing protocols was followed up. Class I resin composite restorations were light-cured using either halogen lamp or light emitting diode at 300 mW/cm2 during 40 seconds or 600 mW/cm2 during 20 seconds. Restorations were evaluated immediately and after 6 and 12 months by two calibrated dentists, according to the modified Ryge criteria. The laboratorial data were submitted to two-way analysis of variance and Newman- Keuls multiple comparison test, or t-test. Clinical data were analyzed by Kappa, Fisher and McNemar tests (\'alpha\' = 0.05). No significant differences were observed for the different light-curing protocols in the degree of conversion, degree of softening in ethanol, and wear produced by the ACTA method (p > 0.05). For the toothbrush abrasion test, irradiation with the light emitting diode unit for 40 seconds at 300 mW/cm2 resulted in higher wear than the other light-curing protocols (p < 0.05). No significant differences were detected at the one-year clinical follow-up of the resin composite restorations submitted to the various light-curing protocols investigated in this study (p > 0.05).
84

Influência de tratamentos superficiais na resistência de união de reparo em resina a base de silorano: análise após envelhecimento / Influence of surface treatment on band strength of repair resin-based silorane: analysis after aging

Guimarães, Raphaella Mendes 23 December 2011 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2014-12-05T14:54:14Z No. of bitstreams: 2 Dissertação - Raphaella Mendes Guimarães - 2011.pdf: 11646606 bytes, checksum: 05767b0e186652fc39182ebc611cd207 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Cláudia Bueno (claudiamoura18@gmail.com) on 2014-12-08T11:50:47Z (GMT) No. of bitstreams: 2 Dissertação - Raphaella Mendes Guimarães - 2011.pdf: 11646606 bytes, checksum: 05767b0e186652fc39182ebc611cd207 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-12-08T11:50:47Z (GMT). No. of bitstreams: 2 Dissertação - Raphaella Mendes Guimarães - 2011.pdf: 11646606 bytes, checksum: 05767b0e186652fc39182ebc611cd207 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2011-12-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The aim of the present study was to evaluate the influence of different surface treatments on bond strength of repair resin-based silorane through microtensile test. 160 silorane blocks were randomly distributed among 40 experimental groups (n=4) resulting from the interaction of three factors under study: surface treatment, adhesive system and resin used to repair. The blocks were stored for 9 days in deionized water at 37°C prior to surface treatment and repair. Repair was performed, after the use of a bonding agent: (Ad 1) Silorane bond or (Ad 2) Adper Scotchbond, with Filtek P90 (P90) or Filtek Z350 XT (Z350 XT) on one of the 10 treatment protocols: control (C), silane (Si), phosphoric acid (Pa), Pa plus Si (PaSi), hydrofluoric acid (Ha), Ha plus Si (HaSi), sandblasting (S), S plus Si (SSi), diamond bur (Db), Db plus Si (DbSi). Blocks were sectioned into beams and after age by storage for six months, subjected to microtensile testing and subsequent analysis in a stereoscope to define the failure types. Additionally, 10 blocks of Filtek P90 composite resin were made for surface analysis by SEM, after completion of surface treatment. Statistical analysis (Mann-Whitney, Kruskal- Wallis and Dunn tests, α=0.05) was performed. The values were statistically influenced by the type of resin (p<0.001) and by the surface treatment (p<0.0001), but not by the bonding agent (p=0,940). SSi, Ha and HaSi produced similar bond strength values, the greatest. Treating the surface with Db showed the worst values and composite resin P90 generated higher bond strength values than Z350 XT to repair silorane surfaces. / O objetivo deste estudo foi avaliar a influência de diferentes tratamentos superficiais na resistência de união de reparo em resina composta à base de silorano, por meio de ensaio de microtração. Foram aleatoriamente distribuídos 160 blocos de resina composta a base de silorano em 40 grupos experimentais (n=4) resultantes da interação entre 3 fatores em estudo: tratamento superficial, sistema adesivo e resina para realizar o reparo. Os blocos confeccionados foram armazenados durante 9 dias em água deionizada a 37°C previamente à realização do tratamento superficial e reparo. O reparo foi realizado após a aplicação do sistema adesivo silorano da Filtek P90 (Ad 1) ou do sistema adesivo Adper Scotchbond Multi-uso (Ad 2), com a resina composta Filtek P90 (P90) ou Filtek Z350 XT (Z350 XT), em um dos dez diferentes tipos de tratamento superficial: controle (C), silano (Si), ácido fosfórico (Af), Af e Si (AfSi), ácido hidrofluorídrico (Ah), Ah e Si (AhSi), jateamento (J), J e Si (JSi), ranhuras (R), R e Si (RSi). Os blocos foram seccionados em forma de palito, em seguida armazenados por seis meses, e então submetidos ao ensaio de microtração e posterior análise em lupa estereoscópica para definição do padrão de fratura. Adicionalmente, foram confeccionados 10 blocos de resina composta Filtek P90 para análise da superfície em MEV, após a realização dos tratamentos superficiais. Os dados obtidos foram submetidos a análise estatística (Mann-Whitney, Kruskal-Wallis e Dunn, α=0,05). Pôde-se verificar que os valores de resistência de união foram estatisticamente influenciados pelo tipo de resina (p<0.001) e pelos tratamentos superficiais (p<0.0001), porém não houve diferença para os adesivos (p= 0,940). JSi, Ah e AhSi foram semelhantes entre si e apresentaram os maiores valores. O emprego de ranhuras resultou nos piores resultados e a resina P90 proporcionou maiores valores de resistência de união do que a resina Z350 XT para reparo em resina composta a base de silorano.
85

Análise da resistência à fratura de dentes caninos de cães (Canis familiaris) submetidos a restaurações biológicas: experimento in vitro / Fracture strength analysis of canine teeth restored biologically: in vitro>/I> study

Herbert Lima Corrêa 01 July 2003 (has links)
Para avaliação da resistência à fratura de dentes caninos de cães restaurados biologicamente (colagem de fragmento) foram utilizados 50 dentes distribuídos em cinco grupos de dez dentes cada. Com exceção dos dentes do grupo 1, que serviram de controle, os demais foram seccionados e posteriormente restaurados com o próprio fragmento (colagem) através de diferentes protocolos: Grupo 2: pino fundido (Níquel-Cromo) e cimento resinoso; Grupo 3: pino de fibra de vidro e cimento resinoso; Grupo 4: pino de fibra de carbono e cimento resinoso; Grupo 5: não foram utilizados pinos, apenas adesivo e resina composta fotopolimerizável (colagem simples). Os dentes foram, então, submetidos a teste de resistência através da aplicação de uma carga perpendicular ao longo eixo do dente na sua face lingual. Os resultados permitiram concluir que a utilização de pinos intra-radiculares teve influência significativa na resistência à fratura dos dentes colados quando comparada ao grupo de colagem simples, no entanto, foi de 45,4 %, 14,2%, 11,4% (respectivamente para os grupos 2, 3 e 4) da resistência necessária para fraturar os dentes íntegros, enquanto para o grupo 5 foi de 7,0 %. Dessa forma, nas condições deste experimento, os protocolos nos quais se utilizam pinos intra-radiculares parecem ser os mais indicados para colagem de dentes caninos fraturados. / To determine the fracture strength of canine teeth of dogs restored biologically (bondind of tooth fragment), 50 teeth were used and distributed in 5 groups of ten teeth each. The group 1 was the control (intact teeth). In the other groups the teeth were sectioned and bonded under different protocols: Group 2: cast post (Nickel-chromium) and resin luting cement; Group 3: Fiberglass post and resin luting cement; Group 4: Carbon fiber post and resin luting cement; Group 5: no post was used, only dentin adhesive and light-cured composite resin (simple bonding). The teeth were submitted to fracture strength test through the application of a perpendicular load to the tooth long axis in its lingual face. The results showed that the use of post improved significant fracture strength of bonding teeth when compared to the group of simple bonding, however this was 45.4%, 14.2%, 11.4% (respectively for the groups 2, 3 and 4) of the load necessary to fracture the sound teeth, whereas was it 7.0% in group 5. In these experimental conditions, the protocols where posts are used seem to be more indicated to bonding tooth fragment in fractured canine tooth.
86

Microinfiltração coronária em dentes tratados endodonticamente correlacionado ao material restaurador provisório: estudo in vitro / Coronal microleakage in endodontic treated teeth correlated to temporary filling material: an in vitro study

Motta, Magno Linhares da 21 May 2009 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-10T14:17:09Z No. of bitstreams: 1 magnolinharesdamotta.pdf: 787435 bytes, checksum: f1496aa1318e46521eaae35e86890c8d (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-10-11T15:53:30Z (GMT) No. of bitstreams: 1 magnolinharesdamotta.pdf: 787435 bytes, checksum: f1496aa1318e46521eaae35e86890c8d (MD5) / Made available in DSpace on 2016-10-11T15:53:30Z (GMT). No. of bitstreams: 1 magnolinharesdamotta.pdf: 787435 bytes, checksum: f1496aa1318e46521eaae35e86890c8d (MD5) Previous issue date: 2009-05-21 / Este trabalho avaliou a microinfiltração marginal em materiais restauradores provisórios utilizados em Endodontia, em diferentes períodos de tempo (3 e 7 dias). Foram utilizados 120 dentes humanos unirradiculares, que após tratamento endodôntico foram separados aleatoriamente em 6 grupos (n=20), de acordo com o material restaurador provisório utilizado: Grupo 1: Vidrion R, Grupo 2: IRM, Grupo 3: Provisory, Grupo 4: Dentalville,, Grupo 5: guta percha e Super Bonder (controle positivo) e Grupo 6: apenas bolinha de algodão (controle negativo). Após a restauração os dentes foram impermeabilizados com esmalte de uso cosmético e submetidos à termociclagem por 500 ciclos (0+/- 5 º C e 55 +/- 5º C). Em seguida foram imersos em solução de azul de metileno 2% por 3 e 7 dias, sendo seccionados longitudinalmente e examinados por lupa estereoscópica com aumento de 40x. Os resultados foram submetidos ao testes estatísticos Mann Whitney e Kruskal Wallis, mostrando resultados significativos quando se utilizou o material Dentalville por um período de 3 dias (p<0,001). Após 7 dias, apenas o grupo 5 (controle positivo) não apresentou microinfiltração marginal, não havendo diferenças estatisticamente significativas entre os demais grupos. Pode-se concluir que o material restaurador provisório Dentalville apresentou menores índices de microinfiltração quando utilizado por um período de 3 dias, comparado aos demais materiais avaliados. / This study evaluated the marginal microleakage in temporary filling materials used in Endodontics, in different time intervals (3 and 7 days). One hundred and twenty uniradicular human teeth comprised the sample of this study. After endodontic treatment they were randomly divided into 6 groups (n=20) according to the temporary restoring material used: Group 1: Vidrion R, Group 2: IRM, Group 3: Provisory, Group 4: Dentalville, Group 5: Gutta percha and Super Bonder (positive control), and Group 6: cotton balls (negative control). After restoration the teeth were were impermeabilized with a nail varnish and submitted to thermocycling with 500 cycles (0+/- 5°C e 55 +/- 5°C). Subsenquently, the teeth were immersed in 2% blue methylene solution for 3 and 7 days, longitudinally sectioned and examined by means of a stereoscopic lens with magnification of 40x. The Mann Whitney and Kruskal Wallis tests were applied for statistical analysis. The results were statistically significant for the Dentalville material at the time interval of 3 days (p<0.001). After 7 days only group 5 (positive control) did not show marginal microleakage, and there was no significant differences between the other groups. It may be concluded that Dentalville temporary restoring material showed the smallest indexes of microleakage at time interval of 3 days when compared to the other materials evaluated.
87

Efeito da ciclagem termo-mecânica na resistência de união e adaptação marginal de sistemas adesivos à dentina / Effect of thermal mechanical cycling in bond strenght and marginal adaptation of adhesives systems on dentin

Oliveira Júnior, Carlos da Cunha, 1979- 27 February 2015 (has links)
Orientadores: Luís Roberto Marcondes Martins, Regina Maria Puppin Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T11:06:52Z (GMT). No. of bitstreams: 1 OliveiraJunior_CarlosdaCunha_D.pdf: 1940639 bytes, checksum: dd88a15626c32be08decb32f8ccbf98d (MD5) Previous issue date: 2015 / Resumo: O objetivo do estudo é avaliar in vitro o efeito da ciclagem termo mecânica na resistência de união push out e adaptação marginal em dentina. Para isso, foram confeccionados 60 blocos de dentina bovina, com dimensões 4mmX4mmX2mm e restaurados com diferentes sistemas adesivos: Single Bonde (SB - 3M), Clearfil SE Bond (CB) e Clearfil SE Protect (CP) (Kuraray). Foram feitas cavidades de 2 mm de diâmetro no centro dos blocos, que foram restaurados com compósito resinoso Z350 cor A3,5, e depois de armazenados em 100% de umidade. Foram polidos com discos Sof-lex da série laranja em sequência decrescente de abrasividade. Em seguida, 30 blocos foram aleatorizados para o grupo controle e os outros 30 foram imersos em fucsina 0,5% por 24h, em seguida, imersos em água por 4h e o excesso de fucsina removido. Foram, então, fotografados para o registro de possíveis fendas formadas. Em seguida, estes blocos foram submetidos à ciclagem mecânica (100.000 ciclos) e térmica (1.000 ciclos). Após o processo de fadiga termomecânica, os blocos foram novamente imersos em fuccina e novas imagens foram registradas. Estas foram analisadas através do software Image J, no qual se registrou o percentual de fendas antes e depois da ciclagem termomecânica pela equação: %fenda = l/lt x 100, onde l é o perímetro da fenda e lt é o perímetro da restauração total. Logo depois, os blocos foram levados ao testes de push out, onde se registrou a resistência de união dos sistemas adesivos estudados que foi comparada com o grupo controle. Os dados foram submetidos ao teste estatístico não paramétrico Kruskal-Wallis e Dunn, por meio do teste de Mann-Whitney para os valores de resitência push out e a análise de percentagem de fendas antes e depois da ciclagem termomecânica se deu pela ANOVA 2 fatores. Os resultados não mostraram diferença estatisticamente significativa entre os grupos no percentual de fendas formadas antes e após a ciclagem termomecânica, mas o grupo ciclado mostrou diferença estatística com o grupo controle, o grupo CP não foi estatisticamente diferente do CB e SB, por outro lado, CB e SB foi estatisticamente diferente. Estes achados sugerem que a ciclagem termomecânica diminuiu significativamente os valores de resistência de união push-out / Abstract: The objective of study to evaluate in vitro the effect of mechanical term cycling on the bond strength push out and marginal adaptation in dentin. For this, were made 60 bovine dentin blocks with dimensions 4mmX4mmX2mm and restored with different adhesive systems: Single Bonde (SB - 3M), Clearfil SE Bond (CB) and Clearfil SE Protect (CP) (Kuraray). 2 mm diameter wells were made in the center of the blocks that have been restored with composite resin Z350 A3,5 color and then stored in 100% humidity. They were polished with Sof-Lex discs orange series in decreasing abrasiveness sequence. Then 30 blocks were randomized to the control group and others 30 were immersed in 0.5% fuchsin for 24 hours, then immersed in water for 4 hours and the fuchsin excess removed. They were photographed to record possible gaps formed. Then these blocks were submitted to mechanical (100,000 cycles) and thermal (1,000 cycles) cycling. After the process of thermomechanical fatigue, the blocks were immersed in fuchsin and new images were recorded. They were analyzed using Image J software, on which registered the percentage of gaps before and after the thermomechanical cycling by the equation: % gap = l / l x 100, where L is the perimeter of the gap and Lt is the total perimeter of the restoration. After, the blocks were taken to push out test where the registered the bond strength of adhesive systems was compared with the control group. Data were subjected to statistical nonparametric Kruskal-Wallis and Dunn, using the Mann-Whitney test for bond strenght to push out, and the analysis values of the percentage of gap before and after the thermomechanical cycling was submited for ANOVA 2way. The results showed no statistically significant difference between groups in the percentage of gap formed before and after thermomechanical cycling, but cycling group showed statistical difference with the control group, the CP group was not statistically different from the CB and SB on the other hand, CB and SB were statistically different. These findings suggest that the thermomechanical cycling decreased the bond strength values push out / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
88

Avaliação da perda mineral decorrente do processo cariogênico e erosivo ao redor de restaurações de cimento de ionômero de vidro / Evaluation of mineral loss after cariogenic and erosive challenges on adjacent enamel glass ionomer cements restorations

Salas, César Felipe Chuquillanqui 01 September 2010 (has links)
O cimento de ionômero de vidro tem mais de 40 anos de uso clínico, com muitas boas qualidades e propriedades de material para forramento e restauração. Como o principal motivo de troca de restaurações é a lesão de cárie secundária, a sua capacidade de indução de remineralização e inibição de desmineralização mostram uma qualidade desejável desse material. Além disso, não se sabe até que ponto o flúor liberado pelos cimentos de ionômeros de vidro é capaz de inibir o processo erosivo. Portanto, o objetivo deste trabalho foi avaliar a capacidade de inibição dos desafios cariogênicos em dentes restaurados com diferentes tipos de materiais ionoméricos restauradores, bem como avaliar a inibição dos mesmos materiais frente a um desafio erosivo. Foram confeccionados 120 fragmentos de dentes bovinos, que foram divididos aleatoriamente em seis grupos, para serem restaurados com diferentes tipos de cimentos de ionômero de vidro (CIV): CIV de alta viscosidade (Fuji IX), CIV modificado por resina (Vitremer), CIV modificado por resina com nanopartículas (N100), CIV modificado por resina encapsulado (Riva Light Cure), CIV de alta viscosidade encapsulado (Riva Self Cure) e um grupo controle com resina composta (Filtek Z350). Após a restauração de tamanho padronizado, seguindo as indicações do fabricante, os espécimes foram submetidos à desafio cariogênico (ciclagem de pH) e erosivo (ácido cítrico). Microdureza superficial do tipo Knoop das amostras foi avaliada inicialmente. Após 24 horas de desafio erosivo, e 5 dias de ciclagem de pH (desafio cariogênico), uma nova avaliação de microdureza foi realizada para avaliar a perda mineral ao redor das restaurações. Na avaliação estatística, utilizou-se o teste de normalidade de Anderson-Darling e teste de homogeneidade de Levene. Para as comparações, foi realizada análise de variância e teste de contraste de Student-Newman Keuls, com nível de significância de 5%. O desafio erosivo reduziu significantemente a dureza superficial, mas nenhuma diferença significante foi observada independentemente do material restaurador (p>0,05). Para análises do esmalte ao redor, diferenças significantes foram observadas com relação aos diferentes materiais (p<0,001) e distâncias das restaurações (p=0,023). Espécimes restauradas com resina apresentaram maior perda mineral e amostras restauradas com CIV convencional de alta viscosidade e CIV encapsulado modificado por resina apresentaram os menores valores de perda mineral. Em conclusão, os CIVs exercem efeito protetor no esmalte apenas contra desafio cariogênico. / The glass ionomer cements (GIC) has more than 40 years been used in clinical practice, with good qualities and properties as dental material of liner and restoration. Since the main reason of restoration replace is secondary caries lesion, the ability of the GIC in inducing remineralization and inhibiting demineralization are important characteristics of this type of material. Furthermore, it is still unclear if the fluoride released by the GIC is able to inhibit the erosive process. Therefore, the aim of this study was to evaluate the ability of inhibition of cariogenic challenge in teeth restored with different types of GIC, as well as to evaluate the inhibition of the same materials concerning erosive challenge. One hundred and twenty samples of bovine teeth were prepared and randomly divided in 6 groups, in order to be submitted to restorative procedures with different types of GIC: High viscous GIC (Fuji IX), resin-modified GIC (Vitremer), resin-modified GIC with nanoparticles (N100), encapsulated resinmodified GIC (Riva Light Cure),encapsulated high viscous GIC (Riva Self Cure) and a control group with resin (Filtek Z350). Knoop microhardness evaluations were initially performed. After performing restorations with standardized dimensions and according to the manufacturers instructions, the samples were submitted to cariogenic challenge (pH cycling) and erosive challenge (citric acid). After 24 h of erosive challenge, and 5 days of pH cycling, new microhardness assessments were performed to evaluate mineral loss around of restorations. For statistical analysis, it was used Anderson-Darling test to test the normality and Levene test to check the homogeneity of the data. To compare the different groups, it was used Analysis of variance and Student-Newman-Keuls post-hoc test, considering the level of significance of 5 %. Erosive challenge significantly reduced enamel surface hardness, but no significant difference was observed irrespectively restorative materials (p>0.05). For enamel analyses, significant differences were observed with respect to the different materials (p<0.001) and distances (p=0.023).Specimens restored with the composite resin presented higher mineral loss and specimens restored with the conventional high viscous GIC and the encapsulated resin-modified GIC presented the lowest values for mineral loss. In conclusion, the GICs exert protective effect only for cariogenic challenge.
89

Comparação in vitro de parâmetros para fotoativação de restaurações em resina composta por meio de microdureza e microscopia eletrônica de varredura / In vitro comparison of parameters for photoactivation of composite resin restorations using hardness and scanning electron microscopy

Shimokawa, Carlos Alberto Kenji 13 September 2013 (has links)
Este estudo in vitro teve como objetivo a comparação de diferentes protocolos para fotoativação de restaurações em resina composta por meio de teste de microdureza e análise da adaptação marginal com microscopia eletrônica de varredura. Foram confeccionadas restaurações de 2mmx4mmx2mm com a resina composta Premisa (Kerr) em 30 dentes bovinos. Durante o procedimento restaurador, o método de fotoativação teve variação, sendo um grupo ativado com o método contínuo (grupo controle) durante 20 segundos, utilizando o fotoativador Elipar Freelight 2; outro grupo utilizou o mesmo equipamento fotoativador, com variação da distância da ponta ativadora, a fim da promoção de um método soft-start (grupo soft-start), tendo distância inicial de 6mm por 20 segundos, seguido de distância mínima por mais 10 segundos; e um terceiro grupo utilizou a tecnologia PLS (grupo DEMI), fornecida pelo equipamento DEMI, que fornece uma luz pulsada e permite a polimerização adequada de uma resina composta em 5 segundos (segundo o fabricante). Após 24 horas de restaurados, mantidos em estufa a 37ºC, os dentes foram seccionados no sentido inciso cervical resultando em 60 corpos de prova, sendo metade deles utilizados em cada teste (N=10). As metades tiveram as superfícies correspondentes ao corte transversal lixadas até a obtenção de superfícies planas e polidas, sendo que 30 delas foram selecionadas aleatoriamente para o teste de microdureza Knoop em 3 diferentes profundidades e as outras 30 metades foram replicadas em resina epóxica para leitura em microscopia eletrônica de varredura. Com as imagens obtidas foram feitas medidas de porcentagem de perímetro de restauração com desadaptação marginal e largura da maior fenda encontrada. Foram aplicados testes estatísticos de análise de variância split plot para os resultados de dureza e one way para a adaptação marginal. Em relação à dureza, os testes mostraram não haver diferença estatisticamente significante entre os grupos avaliados, enquanto houve diferença nas diferentes profundidades (p<0,0001), sendo a dureza na região profunda maior do que na média, que foi maior do que na superficial. Para a adaptação marginal, os testes não mostraram diferença estatisticamente significante para a largura de maior fenda encontrada entre os grupos controle e DEMI, somente o grupo soft-start foi diferente dos outros grupos (p=0,0064), tendo ele os menores valores. Apesar de a porcentagem de perímetro com desadaptação marginal ter apresentado valores com grandes valores de desvio padrão, foi encontrada diferença estatisticamente significante entre os grupos controle e DEMI, mas não entre os grupos DEMI e soft-start. O teste de correlação de Pearson demonstrou correlação linear positiva entre largura da maior fenda encontrada e porcentagem de perímetro com desadaptação marginal. Foi possível a conclusão de que o protocolo de fotoativação soft-start melhorou a adaptação marginal das restaurações em resina composta, sem alterar a dureza do material; o equipamento fotoativador DEMI, com a utilização da tecnologia PLS, teve resultados sem diferença estatisticamente significante na avaliação da adaptação marginal, quando comparados ao grupo controle; nenhum dos protocolos de fotoativação testados causou alteração na dureza da resina composta fotoativada, quando comparadas entre si, havendo aumento dessa propriedade conforme houve aumento da profundidade. / This in vitro study aimed to compare different protocols for the photoactivation of composite resin restorations using microhardness test and analysis of marginal adaptation with scanning electron microscopy. Restorations with 2mmx4mmx2mm were made in 30 bovine teeth using the composite resin Premisa (Kerr). During the restorative procedure, the polymerization method had change, being one group activated with the continuous method (control group) for 20 seconds using the curing unit Elipar Freelight 2, another group used the same curing unit equipment, varying the distance from the activator tip in order to promote a soft-start method (soft-start group), with initial distance of 6mm for 20 seconds, followed by minimum distance for 10 seconds, and a third group used technology PLS (DEMI group) supplied from the DEMI, which provides a pulsed light and allows an adequate polymerization of a resin composite in 5 seconds (according to manufacturer). 24 hours after restoration, maintained at 37 ° C, the teeth were sectioned incisocervical towards resulting in 60 specimens, half of them being used in each test (N = 10). The halves were sanded on the transversal section surfaces to obtain flat and polished surfaces, of which 30 were randomly selected for Knoop microhardness testing in 3 different depths and the other 30 halves were replicated in epoxy resin for microscopy scanning electron reading. Measures of percentage of perimeter with marginal desadaptation and width of the largest slot found were made with the obtained images. Split plot analysis of variance tests were applied to hardness results and one way to the marginal adaptation. Regarding the hardness, tests showed no statistically significant difference among the groups, while there were differences at different depths (p<0,0001), being the hardness of the deep region highest than the medium, which was higher than the superficial. For marginal adaptation, tests showed no statistically significant difference for the width of the largest slot found between the control group and DEMI, only the soft-start group was different from the other groups (p=0,0064), having the lowest values. Despite the large standard deviations shown by the percentage of perimeter with marginal desadaptation, statistically significant difference was found between the control and DEMI, but not between groups DEMI and soft-start. The Pearson correlation test showed positive linear correlation between the width of the largest slot found and the percentage of perimeter with marginal desadaptation. It was possible to conclude that the soft-start photoactivation protocol improved the marginal adaptation of composite resin restorations, without changing the hardness of the material; DEMI curing unit equipment, using PLS technology, showed no statistically significant difference in the evaluation of marginal adaptation, comparing with the control group; none of the protocols tested photoactivation caused change in hardness of composite resin when compared to each other, with an increase of this property as the depth increased.
90

Condição dentária e restauradora de pacientes idosos de um Centro de Referência ao Idoso da Zona Norte de São Paulo / Dental status of Brazilian elderly people at a public service in Sao Paulo, Brazil

Lachowski, Karina Monteleone 03 February 2015 (has links)
O número de idosos vem crescendo em todo o mundo devido a um aumento na expectativa de vida e diminuição da taxa de natalidade. Concomitantemente, os avanços da ciência e da tecnologia na área da saúde poderiam contribuir para a manutenção de dentes por períodos mais prolongados, gerando um crescente número de idosos com dentes na boca. O objetivo dessa pesquisa foi conhecer a condição dentária e restauradora de pacientes idosos de um centro público que oferece tratamento dentário em São Paulo, Brasil. Materiais e métodos: Foram avaliados pacientes (60 anos ou mais) que compareceram ao serviço de triagem do CRI-Norte. Todos os pacientes foram entrevistados inicialmente (dados pessoais, história odontológica, hábitos de higiene). Pacientes dentados foram submetidos a um exame clínico: dentes perdidos, condição dos dentes e restaurações presentes. Para comparação foram utilizados os testes ANOVA e Qui-quadrado (p<0.05). Resultados: Foram avaliados 177 pacientes desdentados (54%) e 148 dentados, sendo 66% do sexo feminino e 34% masculino. 49,8% possuíam entre 60-69 anos e 63% nasceram na Região Sudeste. 73% dos pacientes não se consultavam com um dentista durante a infância, nem possuíam o hábito de realizar consultas periódicas durante a vida adulta (72%). Pacientes dentados (20%) frequentaram o consultório odontológico mais regularmente que os desdentados (8%). 80% dos pacientes dentados relataram escovar os dentes de 1 a 2 vezes por dia e 64% não fazem uso do fio dental. 32% dos pacientes apresentavam entre 5 e 19 dentes e apenas 6,5% apresentavam mais de 20 dentes na boca. Dentre os pacientes desdentados, 70% eram mulheres e 30% eram homens. O CPOD encontrado foi de 26, com predominância do componente perdido (média=21). Dentes inferiores anteriores são os mais retidos pela população idosa (41%). 14,6% dos dentes avaliados apresentaram lesão cariosa (63% lesões coronárias e 37% radiculares). A face coronária mais atingida por cárie foi a mesial (27%). 33% dos dentes presentes apresentaram restaurações sendo 60% satisfatórias e 40% insatisfatórias. 41% das restaurações de amálgama apresentaram-se satisfatórias com diferença estatística comparada a resina composta (13%). Em relação às faces coronárias restauradas, a oclusal foi a que mais apresentou essa condição (31%). Os pré molares foram os dentes com mais restaurações radiculares (48%). 40% dos pacientes apresentaram lesão cervical não cariosa (54% das lesões ocorreram em dentes anteriores), Pré molares (38%) e incisivos (34%) são os dentes mais atingidos por esse tipo de perda de estrutura. Em relação ao desgaste incisal/oclusal, 73% dos pacientes apresentaram essa condição (98% das lesões ocorreram em dentes anteriores). Conclusão: Conclui-se que no serviço público o número de pacientes idosos totalmente desdentados é relevante. Uma pequena parcela dos pacientes apresenta mais que 20 dentes, sendo que muitas restaurações não apresentam-se satisfatórias. O amálgama é a restauração que mais se manteve satisfatoriamente. Uma maior atenção deve ser dada aos tratamentos realizados e à conservação deles na população idosa. / The number of elderly people is increasing all over the world due to increased life expectancy and decreasing birth rate. Simultaneously, the progress of science and technology in health could contribute to the maintenance of teeth in the mouth for longer periods, generating an increasing number of older patients with teeth in the mouth.Objective: Identify the restorative and dental status of elderly patients at a public service in Sao Paulo-Brazil. Methods: Patients (60 years or older) who attended the dental service of CRI-Norte, in São Paulo, Brazil were evaluated. They were submitted to an initial interview which consisted in: personal data, dental history and hygienic habits. Dentate patients were submitted to a clinical examination to evaluate the status of the remaining teeth and conditions of restorations. ANOVA and Chi-square tests (p <0.05) were used for comparison. Results: 177 edentulous and 148 dentate patients were evaluated (66% female and 34% male). 49.8% were 60-69 years old and 65% were born in Southeastern Brazil. 73% had not been to a dental office during childhood and 72% had not regularly been to the dentist\'s in adult life. 20% of dentate and 8% of edentulous attended a dental office regularly. 80% of dentate brushed their teeth 1-2x per day and 64% did not use dental floss. 32% of patients had 5-19 teeth and 6.5% had over 20 teeth. 41% were anterior mandibular teeth. The number of decayed, missing and filled teeth was 26, with prevalence of missing component (mean =21); 14,6% had caries (37% radicular). 33% of the teeth presented restorations (40% unsatisfactory). 41% of amalgam restorations were satisfactory with statistical difference from composite resin (13%). Pre molars were the most radicular restored teeth (48%) with statistical difference between other teeth. 40% of patients presented non-carious lesions; 73% presented incisal/occlusal wear (98% anterior teeth). Conclusion: The number of edentulous patients is relevant. Few patients have more than 20 teeth, and many restorations are not satisfactory. Amalgam is the material that presented the best survive hability. Greater attention should be given to the performed dental treatments and their conservation in the elderly population, increasing their quality of oral health.

Page generated in 0.0297 seconds