• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 3
  • Tagged with
  • 50
  • 22
  • 19
  • 13
  • 12
  • 12
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Estudo experimental das relações entre kerma no ar e equivalente de dose ambiente em barreiras secundárias de salas radiológicas / Experimental study of the conversion coefficient from Air Kerma to Ambient Dose Equivalent for secondary barriers in diagnostic radiological facilities

Alejandro Heyner Lopez Gonzales 12 December 2014 (has links)
No Brasil, para fins de planejamento de barreiras físicas em instalações radiográficas ou para a verificação dos níveis de restrição de dose em levantamentos radiométricos, deve ser usada a grandeza operacional equivalente de dose ambiente. Na prática, os monitores de radiação utilizados em proteção radiológica apresentam suas leituras na grandeza dosimétrica kerma no ar. Portanto, é preciso utilizar um coeficiente que converta esta grandeza dosimétrica na grandeza operacional recomendada. As normas nacionais estabelecem que o coeficiente de conversão no valor de 1,14 Sv/Gy deve ser usado para realizar esta operação, desconsiderando a diferença na distribuição espectral dos fótons dos feixes de raios X comumente encontrados em salas de radiologia convencional. O presente trabalho tem por objetivo determinar os coeficientes de conversão considerando a distribuição espectral da radiação secundária e secundária transmitida através de placas de argamassa baritada. Para atingir os objetivos propostos, foi desenvolvida uma metodologia experimental para as medições dos espectros das radiações secundárias e secundárias transmitidas usando um sistema espectroscópico com detector de CdTe e uma câmara de ionização de 1800 cm3. A região torácica de um objeto simulador antropomórfico, RANDO® Man, foi usada como região espalhadora. Foram utilizadas tensões no tubo entre 40 kV e 150 kV com intervalos na tensão de 10 kV. Os ângulos de espalhamento foram de 30°, 60°, 90° 120° e 150° em relação ao eixo do feixe primário. Como atenuador da radiação secundária foram utilizadas placas de argamassa baritada com espessuras de aproximadamente 10, 15, 20 e 25 mm. Os resultados mostram que, para a radiação secundária, os coeficientes de conversão são maiores que o valor estabelecido no Brasil. Num exemplo típico de levantamento radiométrico, a estimativa do equivalente de dose ambiente determinado usando o coeficiente de conversão calculado a partir dos espectros resultou em um valor cerca de 40 % superior ao equivalente de dose ambiente calculado a partir do coeficiente adotado pela norma nacional. / In Brazil, for planning purposes of the physical barriers in a radiographic installation and for levels verification of dose restriction in radiometric surveys, the ambient dose equivalent operational quantity should be used. In practice, radiation monitors used in radiation protection, are calibrated in dosimetry quantity air kerma. Therefore, it is important to use a conversion coefficient, which turns this dosimetric quantity into a recommended operational quantity. The rules followed in Brazil still establish that the value of the conversion coefficient, 1.14 Sv/Gy, must be used in area monitoring, disregarding differences between the beam types with different photon spectral distribution, commonly found in conventional radiology rooms. Consequently, this work aims to determine the conversion coefficients considering the spectral distribution of the secondary radiation and secondary-transmitted radiation through barium mortar plates. To achieve the proposed objectives, it has been developed an experimental method for measurement of secondary and secondary transmitted spectra using a spectroscopic system with CdTe detector and an ionization chamber 1800 cm3. The thoracic region of an anthropomorphic phantom, RANDO® Man, was used as a scatter region. The voltages used began 40 kV up to 150 kV in displacements of 10 kV, the scattering angles were 30°, 60°, 90° 120° and 150° with respect to the axis of the primary beam. As attenuator object of the secondary radiation was used barium mortar plates with thicknesses of 10, 15, 20 and 25 mm approximately. The results show that for the secondary radiation, the conversion coefficients are greater than the value set in Brazil. In a typical example of radiometric survey, the estimated ambient dose equivalent using the conversion coefficient calculated from the spectra, is a 40% higher compared to the value obtained using the coefficient recommended in Brazil.
42

Avaliação de sistemas de controle automático de exposição em tomografia computadorizada / Evaluation of Automatic Exposure Control Systems in Computed Tomography

Thamiris Rosado Reina 15 August 2014 (has links)
O desenvolvimento da tecnologia de tomografia computadorizada (TC) trouxe maiores possibilidades em medicina diagnóstica. É um método não invasivo de se explorar o corpo humano detalhadamente. Com o aumento das aplicações em TC, aumenta a preocupação com as altas taxas de dose administradas quando comparada com outras modalidades de diagnóstico por imagem. A comunidade científica e os fabricantes uniram esforços para alcançar níveis menores de dose possíveis, sem comprometer a qualidade da imagem diagnóstica. O maior e relativamente novo avanço nessa busca para diminuir os níveis de dose é o controle automático de exposição (CAE) em TC. Esses sistemas foram projetados para ponderar a distribuição de dose ao longo do comprimento de varredura e entre pacientes, levando em consideração o tamanho e as diferentes densidades de tecidos irradiados. Baseando-se na geometria de aquisição em TC, os sistemas CAE são altamente complexos. Sendo assim, sua forma de funcionamento ainda não é inteiramente conhecida. O presente trabalho tem como objetivo avaliar o desempenho clínico dos sistemas CAE, suas susceptibilidades ao usuário e, com isso, ajudar na otimização de dose em pacientes. A abordagem utilizada para avaliar os sistemas CAE de três dos maiores fabricantes de TC no Brasil, General Electric, Philips e Toshiba, foi pela extração dos valores de corrente anódica do cabeçalho da sequência de imagens no padrão DICOM, medição e análise do ruído das imagens dessas sequências e a medição da distribuição da dose ao longo do comprimento de varredura nas superfícies e dentro de dois simuladores de paciente de formatos diferentes. A variação da corrente anódica de cada equipamento de TC associada à qualidade da imagem resultante fornece o desempenho do sistema CAE. As medições de distribuição de dose fornecem o perfil de dose resultante da modulação de corrente. Medições com e sem o sistema CAE acionado foram feitas para quantificar a importância em termos de dose desses sistemas. Os resultados obtidos permitem otimizações no uso dos sistemas CAE e, consequentemente, a redução da dose no paciente sem comprometer a qualidade diagnóstica da imagem. / The development of the computed tomography (CT) technology has brought wider possibilities on diagnostic medicine. It is a non-invasive method to see the human body in details. As the CT application increases, it raises the concern about patient dose, because the higher dose levels imparted compared to other diagnostic imaging modalities. The radiology community (radiologists, medical physicists and manufacturer) are working together to find the lowest dose level possible, without compromising the diagnostic image quality. The greatest and relatively new advance to lower the patient dose is the automatic exposure control (AEC) systems in CT. These systems are designed to ponder the dose distribution along the patient scanning and between patients taking into account their sizes and irradiated tissue densities. Based on the CT scanning geometry, the AEC-systems are very complex and their functioning is yet not fully understood. This work aims to evaluate the clinical performance of AEC-systems and their susceptibilities to assist on possible patient dose optimizations. The approach to evaluate the AEC-systems of three of the leading CT manufacturers in Brazil, General Electric, Philips and Toshiba, was the extraction of tube current modulation data from the DICOM standard image sequences, measurement and analysis of the image noise of those image sequences and measurement of the dose distribution along the scan length on the surface and inside of two different phantoms configurations. The tube current modulation of each CT scanner associated to the resulted image quality provides the performance of the AEC-system. The dose distribution measurements provide the dose profile due to the tube current modulation. Dose measurements with the AEC-system ON and OFF were made to quantify the impact of these systems regarding patient dose. The results attained give rise to optimizations on the AEC-systems applications and, by consequence, decreases the patient dose without compromising the diagnostic image quality.
43

Panorama das exposições médicas em radiologia convencional no Estado de São Paulo / Overview of the medical exposures in coventional radiology in the State of São Paulo

Freitas, Marcelo Baptista de 07 March 2005 (has links)
A dosimetria de pacientes associada à avaliação das condições de funcionamento dos equipamentos médicos e aos procedimentos empregados na realização dos exames, desempenha um papel fundamental no sistema de proteção radiológica das exposições médicas. Nesse sentido, foi realizado um levantamento em grande escala das doses recebidas pelos pacientes submetidos a exames radiológicos convencionais realizados em uma amostra representativa de estabelecimentos de saúde do estado de São Paulo. Nesse levantamento foi empregado um kit dosimétrico postal originalmente desenvolvido, que permitiu a determinação da dose de entrada na pele (DEP) através da técnica de dosimetria termoluminescente. Paralelamente foram realizadas visitas in-loco a uma sub-amostra de estabelecimentos, onde as condições de funcionamento dos equipamentos de raios X médicos e do sistema de imagem foram avaliadas empregando-se procedimentos e equipamentos já estabelecidos em protocolos de controle de qualidade. O estudo completou-se com a elaboração de um catálogo de espectros na faixa de energia do radiodiagnóstico, que, através de procedimento desenvolvido, permitiu inferir espectros equivalentes em equipamentos médicos. Na determinação dos espectros foi empregado um detector semicondutor de telureto de cádmio e zinco (CdZnTe), cujas curvas de eficiência e escape foram determinadas experimentalmente para realização do processo de correção dos espectros (stripping procedure). O processo de amostragem de estabelecimentos de saúde realizado neste estudo permitiu verificar a distribuição de equipamentos de diagnóstico por imagem e a freqüência de exames radiológicos no estado de São Paulo. A partir desses resultados foram escolhidos os exames de tórax, crânio (e seios da face) e coluna para avaliação de DEP, uma vez que os mesmos apresentam as maiores freqüências anuais de exames por 1.000 habitantes: 100, 46 e 29, respectivamente. Na técnica de amostragem dos estabelecimentos de saúde incluídos neste estudo foi empregado como critério de estratificação a quantidade anual de exames radiológicos associados ao município de localização do estabelecimento. Do total de 200 estabelecimentos sorteados, 50 participaram da primeira etapa e 38 da segunda. Um total de 83 salas de exames (ou equipamentos) e 868 pacientes foram incluídos, e um conjunto de 1415 valores de DEP foi determinado. O resultado da distribuição dos valores de DEP permitiu determinar os chamados níveis de referência, que, no caso de pacientes adultos, se mostraram bastante semelhantes aos encontrados em outros estudos internacionais. No caso de pacientes infantis, a situação é bem diferente, obtendo-se valores pelo menos 2 vezes superiores a outros recomendados internacionalmente para a radiografia infantil mais freqüente (tórax). Esse fato sugere que as práticas empregadas na realização dos exames devem ser revisadas e que recomendações específicas a esse grupo de pacientes, a partir de estudos dirigidos, sejam publicadas. Constatou-se também alguns casos de DEP elevada pelo uso desnecessário de radioscopia de localização. Os testes de desempenho dos equipamentos e a avaliação das imagens realizadas sugerem que há possibilidade de melhoria das condições de realização dos exames, sem perda de informação diagnóstica presente na imagem e com redução das doses. Alguns espectros de raios X determinados experimentalmente apresentaram divergência em relação a outros catálogos já estabelecidos, numa faixa específica de energia do espectro (entre 25 e 40 keV). Para a sua utilização em situações práticas há necessidade de algumas correções na curva de eficiência, o que não inviabiliza a metodologia e os procedimentos estabelecidos. De forma geral, os resultados encontrados neste estudo permitem traçar um panorama das exposições médicas em radiologia convencional no estado de São Paulo, contribuindo para o aperfeiçoamento de futuras pesquisas que sejam realizadas na área, ou mesmo, para a implementação de políticas públicas. / Patients dosimetry, associated with the assessment of the performance of the radiological equipment and of the series of procedures employed in the accomplishment of the examinations, plays fundamental role in the radiation protection system of medical exposures. Therefore, a large-scale survey of absorbed doses was carried out in health services localized in the state of São Paulo, including patients submitted to conventional radiological examinations. In this survey a postal dosimetric kit, originally developed, was employed. It allows the evaluation of the entrance surface dose (ESD) to patients with thermoluminescence dosimeters. Also a series visits to a sub-sample of services was carried out, giving rise to the in-loco evaluation of the performance of the medical x-ray equipment and of the image system, using procedures and equipments already established in protocols of quality control. The study is completed with the elaboration of a catalogue of x-ray spectra, which provides means to infer the spectra generated by medical x-ray equipments. Measurements of x-ray spectra were carried out with a cadmium zinc telluride detector (CdZnTe), and the stripping procedure was performed taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined in this work. The stratified sampling technique furnished important data on the distribution of equipments and the annual frequency of examinations performed in the state of São Paulo. From these results radiological examinations of the chest, skull and sinus, and spine were selected for the evaluation of ESD, as their annual frequencies are the highest observed: 100, 46 and 29 per thousand inhabitants, respectively. The number of x-ray examinations carried out annually in the cities of the state was employed as the stratification criterion to construct the sample. From a total of 200 health services sampled, 50 agreed to participate of the first stage, and 38 of the second. A total of 83 rooms (or x-ray equipments) and 868 patients was included, and a set of 1415 values of ESD was measured. Diagnostic reference levels were determined with the outcomes of the distribution of ESD. For adult patients, the reference levels achieved are very similar to others obtained in international surveys. However, as far as pediatric patients are concerned, the situation is very different: the values found in this survey are twice larger than the international recommendations to chest radiography of children. This points out that the practices need to be revised and that specific recommendations to this patient group, following specific surveys, should be provided. Also, a series of high ESD values due to unnecessary localizing radioscopy were detected among our data. The results of the equipment performance tests and of the evaluation of image quality suggest that it is possible to improve the conditions of the examinations and to reduce doses to patients, without impairment of the diagnostic information. Some of the experimentally determined x-ray spectra show a discrepancy, when compared to other catalogue spectra, in a particular energy range 25 to 40 keV. The practical application of them will require some corrections in the efficiency curve, but the established methodology and procedures remain legitimate. In an extensive approach, the results of this study supply a panorama of medical exposures in conventional radiology in the state of São Paulo, contributing with resources to future research in the field and also to governmental actions.
44

Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica / Evaluation of personal protective devices used in diagnostic radiology

Soares, Fernanda Cristina Salvador 09 October 2006 (has links)
Neste trabalho foram avaliados aventais de proteção e blindagens de ovário de cinco fabricantes segundo as normas NBR / IEC 61331-1 e NBR / IEC 61331-3 de 2004. Para a determinação da espessura equivalente de atenuação foram aplicadas três metodologias diferentes (interpolação linear, modelo de Archer e somatório de exponenciais), uma vez que a norma não indica como este valor deve ser obtido. Além disso, foram estimadas as incertezas associadas a cada método e a influência do número de medições na incerteza combinada. As características de confecção avaliadas foram: documento acompanhante, projeto, materiais, dimensões e marcação da etiqueta. Para esta avaliação foi elaborado um formulário que contemplava todas as exigências da NBR / IEC 61331-3. Os resultados mostraram uma grande diferença entre os valores de espessura equivalente de atenuação declarados e medidos. A comparação dos resultados das três metodologias aplicadas mostrou que há pouca variação entre os valores obtidos e entre as incertezas associadas nas diferentes metodologias. Foi possível observar também que o número de medições não contribui significativamente para o aumento da incerteza nas três metodologias. A metodologia que melhor se adequou à rotina do laboratório foi a metodologia da interpolação linear com cinco medições da taxa de kerma no ar. A discrepância entre os resultados apresentados neste trabalho e as exigências das normas estudadas mostra a necessidade de tornar compulsória a certificação dos dispositivos de proteção, contribuindo assim para o aumento da proteção radiológica do usuário. / In this work protective devices of five manufacturers were evaluated according to the NBR/IEC 61331-1 and NBR/IEC 61331-3 standards. Three different methodologies (linear interpolation, Archer model and sum of exponentials) were applied for the determination of the attenuation equivalent, since the standard does not indicate how it must be determined. Moreover, the uncertainties associated to each method, and the influence of the number of measurements in the combined uncertainty were estimated. The evaluated manufacture characteristics were: accompanying document, design, materials, dimensions and label marking. For this evaluation a check list about the requirements of the NBR/IEC 61331-3 standard was elaborated. The results showed a great difference between nominal and measured attenuation equivalent values. The comparison of the results using the three methodologies showed small variations among the obtained values and among the associated uncertainties in the different methodologies. It was possible to observe that the number of measurements does not contribute significantly for the increase of the uncertainty in all three methodologies. The best methodology for the laboratory routine is the linear interpolation methodology, with five measurements for each air kerma rate value. The discrepancy between the results obtained in this work and the requirements of the applied standards show the need to adopt a compulsory certification process for protective devices, thus contributing for the increase of the radiation protection of the users.
45

Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica / Evaluation of personal protective devices used in diagnostic radiology

Fernanda Cristina Salvador Soares 09 October 2006 (has links)
Neste trabalho foram avaliados aventais de proteção e blindagens de ovário de cinco fabricantes segundo as normas NBR / IEC 61331-1 e NBR / IEC 61331-3 de 2004. Para a determinação da espessura equivalente de atenuação foram aplicadas três metodologias diferentes (interpolação linear, modelo de Archer e somatório de exponenciais), uma vez que a norma não indica como este valor deve ser obtido. Além disso, foram estimadas as incertezas associadas a cada método e a influência do número de medições na incerteza combinada. As características de confecção avaliadas foram: documento acompanhante, projeto, materiais, dimensões e marcação da etiqueta. Para esta avaliação foi elaborado um formulário que contemplava todas as exigências da NBR / IEC 61331-3. Os resultados mostraram uma grande diferença entre os valores de espessura equivalente de atenuação declarados e medidos. A comparação dos resultados das três metodologias aplicadas mostrou que há pouca variação entre os valores obtidos e entre as incertezas associadas nas diferentes metodologias. Foi possível observar também que o número de medições não contribui significativamente para o aumento da incerteza nas três metodologias. A metodologia que melhor se adequou à rotina do laboratório foi a metodologia da interpolação linear com cinco medições da taxa de kerma no ar. A discrepância entre os resultados apresentados neste trabalho e as exigências das normas estudadas mostra a necessidade de tornar compulsória a certificação dos dispositivos de proteção, contribuindo assim para o aumento da proteção radiológica do usuário. / In this work protective devices of five manufacturers were evaluated according to the NBR/IEC 61331-1 and NBR/IEC 61331-3 standards. Three different methodologies (linear interpolation, Archer model and sum of exponentials) were applied for the determination of the attenuation equivalent, since the standard does not indicate how it must be determined. Moreover, the uncertainties associated to each method, and the influence of the number of measurements in the combined uncertainty were estimated. The evaluated manufacture characteristics were: accompanying document, design, materials, dimensions and label marking. For this evaluation a check list about the requirements of the NBR/IEC 61331-3 standard was elaborated. The results showed a great difference between nominal and measured attenuation equivalent values. The comparison of the results using the three methodologies showed small variations among the obtained values and among the associated uncertainties in the different methodologies. It was possible to observe that the number of measurements does not contribute significantly for the increase of the uncertainty in all three methodologies. The best methodology for the laboratory routine is the linear interpolation methodology, with five measurements for each air kerma rate value. The discrepancy between the results obtained in this work and the requirements of the applied standards show the need to adopt a compulsory certification process for protective devices, thus contributing for the increase of the radiation protection of the users.
46

Avaliação dos níveis de radiação ambiental no laboratório de tomografia por emissão de pósitrons acoplada a tomografia computadorizada, microPET/CT / Evaluation of ambient radiation levels in positron emission tomography/computed tomography in microPET/CT laboratory

Sarmento, Daniele Martins 24 May 2016 (has links)
O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas. / Micro PET/CT scanner is an essential tool generally used for small animal molecular imaging. Fluorine-18-labeled fluorodeoxyglucose is the most widely used radioisotope in this technique. The present study aimed to evaluate the radiation levels in a micro PET/CT research laboratory of the Radiopharmacy Center at IPEN-CNEN / SP, in order to accomplish both national standards and international recommendations. The radioprotection team has classified the laboratory as supervised area; even this laboratory does not require the adoption of specific measures for protection and safety, should be done regular re-evaluation of the conditions of occupational exposures. Workplace monitoring and individual control assessment were carried out to ensure the radiological protection of all workers directly involved in handling the scanner. Initially, there was conducted a radiometric survey, as well as measurements of the external radiation level in the workplace and its surroundings. To achieve this goal, there were placed nine thermoluminescent dosimeters of CaSO4:Dy in preselected locations. Monthly evaluations of the occupationally exposed individuals were carried out through the use of TL dosimeters, ported in the workers´ chest. Moreover, whole body measurements were performed every six months. The study period was about two-years which started in April 2014. All tests to evaluate micro PET/CT performance were based on the standard protocol of the equipment in accordance with the standard developed by the Animal PET Standard Task Force. Present study\'s results demonstrated that the ambient radiation levels (ambient and effective estimated radiation dose), as well as the effective shielding equipment are both adequate. This study emphasizes that it is essential to strictly follow the principles of radioprotection in workplace, whenever researches involve radioactive unsealed sources.
47

Avaliação dos níveis de radiação ambiental no laboratório de tomografia por emissão de pósitrons acoplada a tomografia computadorizada, microPET/CT / Evaluation of ambient radiation levels in positron emission tomography/computed tomography in microPET/CT laboratory

Daniele Martins Sarmento 24 May 2016 (has links)
O sistema microPET/CT é um importante equipamento utilizado nas pesquisas de imagem diagnóstica em pequenos animais. O radiofármaco mais usado nesta tecnologia é o fluordeoxiglicose marcado com flúor-18. Este estudo tem como objetivo efetuar o controle radiológico no laboratório de pesquisa microPET/CT do Centro de Radiofarmácia do IPEN-CNEN/SP, de forma a satisfazer tanto as normas nacionais como as recomendações internacionais. O laboratório está classificado pela equipe de radioproteção da instalação como área supervisionada, nas quais embora não seja obrigatória a adoção de medidas específicas de proteção e segurança, devem ser submetidas reavaliações regulares das condições do ambiente de trabalho. Visando assegurar a proteção radiológica dos trabalhadores diretamente envolvidos no manuseio do equipamento, realizou-se o monitoramento do local de trabalho e a avaliação do controle de dose individual. Inicialmente foi feito o monitoramento pré-operacional, isto é, o levantamento radiométrico no laboratório. Além disso, mediu-se nível de radiação externa nas instalações do laboratório e suas adjacências, por meio da colocação de nove dosímetros termoluminescentes (TL) de CaSO4:Dy, em locais previamente selecionados. Os indivíduos ocupacionalmente expostos foram avaliados mensalmente por meio do uso de dosímetros TL posicionados no tórax e por medidas de corpo inteiro, tomadas a cada seis meses. O período do estudo foi de dois anos, com início em abril de 2014. Para o controle do microPET/CT realizou-se testes de desempenho de acordo com o protocolo padrão do equipamento e em conformidade com a norma desenvolvida pela força tarefa para estudos com PET em animais Animal PET Standard Task Force. O presente estudo permitiu demonstrar que os níveis de radiação das áreas (estimativas de dose ambiente e dose efetiva), assim como a blindagem do equipamento estão adequados de acordo com os limites da exposição ocupacional. Ressalta-se a importância de se seguir rigorosamente os princípios de radioproteção, já que se trata de pesquisas com fontes radioativas não seladas. / Micro PET/CT scanner is an essential tool generally used for small animal molecular imaging. Fluorine-18-labeled fluorodeoxyglucose is the most widely used radioisotope in this technique. The present study aimed to evaluate the radiation levels in a micro PET/CT research laboratory of the Radiopharmacy Center at IPEN-CNEN / SP, in order to accomplish both national standards and international recommendations. The radioprotection team has classified the laboratory as supervised area; even this laboratory does not require the adoption of specific measures for protection and safety, should be done regular re-evaluation of the conditions of occupational exposures. Workplace monitoring and individual control assessment were carried out to ensure the radiological protection of all workers directly involved in handling the scanner. Initially, there was conducted a radiometric survey, as well as measurements of the external radiation level in the workplace and its surroundings. To achieve this goal, there were placed nine thermoluminescent dosimeters of CaSO4:Dy in preselected locations. Monthly evaluations of the occupationally exposed individuals were carried out through the use of TL dosimeters, ported in the workers´ chest. Moreover, whole body measurements were performed every six months. The study period was about two-years which started in April 2014. All tests to evaluate micro PET/CT performance were based on the standard protocol of the equipment in accordance with the standard developed by the Animal PET Standard Task Force. Present study\'s results demonstrated that the ambient radiation levels (ambient and effective estimated radiation dose), as well as the effective shielding equipment are both adequate. This study emphasizes that it is essential to strictly follow the principles of radioprotection in workplace, whenever researches involve radioactive unsealed sources.
48

Reduzir a dose de radiação em crianças que realizaram tomografia computadorizada de crânio não traz prejuízo ao diagnóstico, motiva a educação permanente e promove campanha de radioproteção / Reducing radiation dose in children who underwent computed tomography does not bring harm to the diagnosis, motivates continuing education and promotes radioprotection campaign

Bernardo, Mônica Oliveira 17 December 2013 (has links)
Made available in DSpace on 2016-04-27T13:10:23Z (GMT). No. of bitstreams: 1 Monica Oliveira Bernardo.pdf: 3960791 bytes, checksum: cdb03a40c1d26631a8419067ae0e81eb (MD5) Previous issue date: 2013-12-17 / Radiological examinations have greatly increased, especially in children after craniocerebral trauma (CCT). Recent studies indicate a higher incidence of cancer and cataracts in children undergoing computed tomography (CT) compared to those without exposure. Some countries have promoted campaigns to avoid unnecessary CT and reducing the radiation dose. Objectives: 1. To assess whether the reduction of radiation dose in CT affect exam interpretation and diagnosis in children with CCT. 2. To stimulate discussion and implementation of measures to reduce the radiation dose received by children requiring health care and, also, stimulating awareness of pediatricians and families about the radiation dangers. Methods: We selected two groups of CT from children with CCT that underwent to CT performed in Philips 64 channels Multi Slice CT scanner at Unimed Hospital (Sorocaba-SP) from January to August 2012. We initially selected the 30 last CT performed with usual radiation dose in children. Then to the next CT for CCT we apply the protocols to reduce radiation load (approximately 50%) according to the guidelines of The Alliance for Radiation Safety in Pediatric Imaging. We reduced the kilovoltage (KV) to the maximum shown by tomography equipment and set a limit to the milliamperes per second (mAs) according to analysis of the tomography equipment after the completion of digitized radiography tomography, according to thickness and length of area of the patient being examined. We oriented the technical team to restrict the exam to the extent of the area requested by the doctor. The two CT series were presented to 19 pediatricians and 02 neurosurgeons from the Emergency Unit and to 7 radiologists from Unimed Hospital blind to the technical differences. The participants answered a specific questionnaire asking if they noticed any difference comparing the two series of exams; if they had any difficulty in making the diagnosis and taking the necessary conduct; if they need any training to exam the CTs and to assess the load of radiation and, finally, if they consider useful to implement a booklet for each child to register his/her radiological examinations. Results: Four participants noticed differences between the CT series and reported greater "noise" (image graininess) in those with reduced radiation load, had no difficulty in making a diagnosis and take the right conduct; most would like to have training and education on radioprotection and all agreed that the booklet to register and control radiological examinations would be useful for education and surveillance of parents and health professionals. Conclusion: This study showed that is possible to reduce the radiation dose in CT scans of children up to 50% without loss in the diagnosis accuracy; health professionals are motivated for continuing education and have attitudes to reduce the load of radiation. The direction of the hospital implemented the booklet to record radiological examinations. The campaign was publicized in the local media and on websites of Unimed Sorocaba and Unimed Brazil and has been well accepted by the hospital community and families / Os exames radiológicos têm aumentado muito, especialmente em crianças pós-trauma crânio-encefálico (TCE). Estudos recentes indicam maior incidência de câncer e catarata em crianças submetidas à tomografia quando comparadas àquelas sem exposição. Alguns países já promovem campanhas para evitar exames desnecessários e reduzir a dose de radiação. Objetivos: 1. Avaliar se a redução da dose de radiação em tomografias computadorizadas (TC) de crânio prejudica a interpretação do exame e o diagnóstico em crianças com TCE. 2. Desencadear no ambiente de trabalho a discussão e implementação de medidas capazes de reduzir a dose de radiação recebida por crianças que necessitem atenção à saúde estimulando também a conscientização dos pediatras e dos familiares. Métodos: Selecionamos dois grupos de TC de crianças com TCE, realizados em tomógrafo Philips Multi Slice de 64 canais no Hospital da Unimed de Sorocaba no período de janeiro a agosto de 2012. Inicialmente selecionamos as 30 últimas TC realizadas com dose de radiação habitual. A seguir, aos próximos exames, aplicamos os protocolos de redução da carga de radiação (aproximadamente 50%) segundo as diretrizes da The Alliance for Radiation Safety in Pediatric Imaging. Reduzimos a Quilovoltagem (KV) ao máximo demonstrado pelo equipamento de tomografia e estabelecemos um limite para a Miliamperagem por segundo (mAs) de acordo com a análise do equipamento de tomografia após a realização da radiografia digitalizada na tomografia, de acordo a espessura e o comprimento da área a ser analisada do paciente. Orientamos a equipe técnica para que restringisse a extensão do exame somente à região solicitada no pedido médico. As duas séries de exames foram apresentados a 19 pediatras, 2 neurocirurgiões da Unidade de Emergência e a 7 radiologistas do Hospital da Unimed Sorocaba que desconheciam as diferenças técnicas. Os participantes responderam por um questionário específico se encontraram diferenças entre os exames; se tiveram dificuldade em fazer o diagnóstico e tomar a conduta necessária; se sentiam necessidade de capacitação para avaliar os exames e a carga de radiação e se consideravam útil a implantação de uma caderneta individual de registro dos exames radiológicos. Resultados: Quatro participantes viram diferenças entre os exames e referiram maior "ruído" (granulação da imagem) naqueles com redução da carga de radiação; não tiveram dificuldade em realizar o diagnóstico e orientar a conduta; a maioria gostaria de ter capacitação e educação preventiva e todos concordam que a caderneta de controle de registro de exames radiológicos seria útil para a educação e vigilância dos pais e profissionais de saúde. Conclusão: O estudo evidenciou ser possível reduzir a dose de radiação em TC de crianças em até 50% sem prejuízo no diagnóstico e na conduta; os profissionais de saúde estão motivados a se capacitarem e a ter atitudes visando reduzir a carga de radiação. A direção do hospital implantou a caderneta de registro de exames radiológicos. A campanha foi divulgada na mídia local e nos sites da Unimed de Sorocaba e na Unimed do Brasil e tem sido bem aceita pela comunidade hospitalar e familiares
49

Panorama das exposições médicas em radiologia convencional no Estado de São Paulo / Overview of the medical exposures in coventional radiology in the State of São Paulo

Marcelo Baptista de Freitas 07 March 2005 (has links)
A dosimetria de pacientes associada à avaliação das condições de funcionamento dos equipamentos médicos e aos procedimentos empregados na realização dos exames, desempenha um papel fundamental no sistema de proteção radiológica das exposições médicas. Nesse sentido, foi realizado um levantamento em grande escala das doses recebidas pelos pacientes submetidos a exames radiológicos convencionais realizados em uma amostra representativa de estabelecimentos de saúde do estado de São Paulo. Nesse levantamento foi empregado um kit dosimétrico postal originalmente desenvolvido, que permitiu a determinação da dose de entrada na pele (DEP) através da técnica de dosimetria termoluminescente. Paralelamente foram realizadas visitas in-loco a uma sub-amostra de estabelecimentos, onde as condições de funcionamento dos equipamentos de raios X médicos e do sistema de imagem foram avaliadas empregando-se procedimentos e equipamentos já estabelecidos em protocolos de controle de qualidade. O estudo completou-se com a elaboração de um catálogo de espectros na faixa de energia do radiodiagnóstico, que, através de procedimento desenvolvido, permitiu inferir espectros equivalentes em equipamentos médicos. Na determinação dos espectros foi empregado um detector semicondutor de telureto de cádmio e zinco (CdZnTe), cujas curvas de eficiência e escape foram determinadas experimentalmente para realização do processo de correção dos espectros (stripping procedure). O processo de amostragem de estabelecimentos de saúde realizado neste estudo permitiu verificar a distribuição de equipamentos de diagnóstico por imagem e a freqüência de exames radiológicos no estado de São Paulo. A partir desses resultados foram escolhidos os exames de tórax, crânio (e seios da face) e coluna para avaliação de DEP, uma vez que os mesmos apresentam as maiores freqüências anuais de exames por 1.000 habitantes: 100, 46 e 29, respectivamente. Na técnica de amostragem dos estabelecimentos de saúde incluídos neste estudo foi empregado como critério de estratificação a quantidade anual de exames radiológicos associados ao município de localização do estabelecimento. Do total de 200 estabelecimentos sorteados, 50 participaram da primeira etapa e 38 da segunda. Um total de 83 salas de exames (ou equipamentos) e 868 pacientes foram incluídos, e um conjunto de 1415 valores de DEP foi determinado. O resultado da distribuição dos valores de DEP permitiu determinar os chamados níveis de referência, que, no caso de pacientes adultos, se mostraram bastante semelhantes aos encontrados em outros estudos internacionais. No caso de pacientes infantis, a situação é bem diferente, obtendo-se valores pelo menos 2 vezes superiores a outros recomendados internacionalmente para a radiografia infantil mais freqüente (tórax). Esse fato sugere que as práticas empregadas na realização dos exames devem ser revisadas e que recomendações específicas a esse grupo de pacientes, a partir de estudos dirigidos, sejam publicadas. Constatou-se também alguns casos de DEP elevada pelo uso desnecessário de radioscopia de localização. Os testes de desempenho dos equipamentos e a avaliação das imagens realizadas sugerem que há possibilidade de melhoria das condições de realização dos exames, sem perda de informação diagnóstica presente na imagem e com redução das doses. Alguns espectros de raios X determinados experimentalmente apresentaram divergência em relação a outros catálogos já estabelecidos, numa faixa específica de energia do espectro (entre 25 e 40 keV). Para a sua utilização em situações práticas há necessidade de algumas correções na curva de eficiência, o que não inviabiliza a metodologia e os procedimentos estabelecidos. De forma geral, os resultados encontrados neste estudo permitem traçar um panorama das exposições médicas em radiologia convencional no estado de São Paulo, contribuindo para o aperfeiçoamento de futuras pesquisas que sejam realizadas na área, ou mesmo, para a implementação de políticas públicas. / Patients dosimetry, associated with the assessment of the performance of the radiological equipment and of the series of procedures employed in the accomplishment of the examinations, plays fundamental role in the radiation protection system of medical exposures. Therefore, a large-scale survey of absorbed doses was carried out in health services localized in the state of São Paulo, including patients submitted to conventional radiological examinations. In this survey a postal dosimetric kit, originally developed, was employed. It allows the evaluation of the entrance surface dose (ESD) to patients with thermoluminescence dosimeters. Also a series visits to a sub-sample of services was carried out, giving rise to the in-loco evaluation of the performance of the medical x-ray equipment and of the image system, using procedures and equipments already established in protocols of quality control. The study is completed with the elaboration of a catalogue of x-ray spectra, which provides means to infer the spectra generated by medical x-ray equipments. Measurements of x-ray spectra were carried out with a cadmium zinc telluride detector (CdZnTe), and the stripping procedure was performed taking into account both the contributions of efficiency and x-ray escape fraction, experimentally determined in this work. The stratified sampling technique furnished important data on the distribution of equipments and the annual frequency of examinations performed in the state of São Paulo. From these results radiological examinations of the chest, skull and sinus, and spine were selected for the evaluation of ESD, as their annual frequencies are the highest observed: 100, 46 and 29 per thousand inhabitants, respectively. The number of x-ray examinations carried out annually in the cities of the state was employed as the stratification criterion to construct the sample. From a total of 200 health services sampled, 50 agreed to participate of the first stage, and 38 of the second. A total of 83 rooms (or x-ray equipments) and 868 patients was included, and a set of 1415 values of ESD was measured. Diagnostic reference levels were determined with the outcomes of the distribution of ESD. For adult patients, the reference levels achieved are very similar to others obtained in international surveys. However, as far as pediatric patients are concerned, the situation is very different: the values found in this survey are twice larger than the international recommendations to chest radiography of children. This points out that the practices need to be revised and that specific recommendations to this patient group, following specific surveys, should be provided. Also, a series of high ESD values due to unnecessary localizing radioscopy were detected among our data. The results of the equipment performance tests and of the evaluation of image quality suggest that it is possible to improve the conditions of the examinations and to reduce doses to patients, without impairment of the diagnostic information. Some of the experimentally determined x-ray spectra show a discrepancy, when compared to other catalogue spectra, in a particular energy range 25 to 40 keV. The practical application of them will require some corrections in the efficiency curve, but the established methodology and procedures remain legitimate. In an extensive approach, the results of this study supply a panorama of medical exposures in conventional radiology in the state of São Paulo, contributing with resources to future research in the field and also to governmental actions.
50

Modificação das posturas dos simuladores antropomórficos voxel de referência Adult Male (AM) e Adult Female (AF) para cálculo de coeficientes de conversão de dose / Posture modification of the reference anthropomorphic voxel phantom Adult Male (AM) and Adult Female (AF) for dose conversion coefficients calculation

Galeano, Diego Castanon 11 October 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Establish limits to the exposure of the population to various ionizing radiation sources is crucial to prevent occupationally exposed individuals and the public, to their deleterious effects. In computational ambit, it is necessary that different exposure scenarios are simulated in order to obtain the dose coefficients (CCs), which relate physical dosimetric quantities - as absorbed dose, Fluency or Kerma Air - with limiting quantities - as equivalent and / or effective dose. Under certain exposure conditions, the individual's posture is not always the same, and the scenario shall be described as realistic as possible. In this work, the AM (Adult Male) and AF (Adult Female) anthropomorphic reference phantom of ICRP publication n° 110 had their postures modified from supine posture (standing) to sitting posture. The change of posture was performed through of a subroutine written in the Visual Monte Carlo code (VMC) to rotate the thigh region of the phantom and position it between the region of the leg and torso. The ScionImage software was used to reconstruct and smooth the knee and hip contours in a sitting posture phantom, and for 3D visualization of phantom was used VolView software. After this step the MCNPX radiation transport code was used for the calculation of fluence-to-dose conversion coefficients (CCs) to six irradiation geometries: AP, PA, LLAT, RLAT, ROT and ISO, recommended by ICRP. The results were compared between the phantoms in standing and sitting postures, for both sexes, in order to assess differences in scattering and absorption of radiation in different postures. The results show significant differences of up to 100% in the equivalent dose conversion coefficients of organs in the pelvic region, 79 % in organs with distribution in the whole body (such as skin, muscle, lymph nodes, bone marrow and trabecular bone) and a difference of 27% to effective dose conversion coefficients. Moreover in order to conduct a comparative study between two types of simulators, was estimated CCs equivalent and effective dose of adult male hybrid simulators, UFHADM, and female, UFHADF, in a sitting posture, and compared to the AM and AF simulators, also in the sitting posture, where it was observed significant difference in energies below 0.05 MeV. This study demonstrated the feasibility of using anthropomorphic phantoms in the sitting posture to represent more realistic postures and can be used in studies in medical and occupational dosimetry. This study demonstrated the feasibility of using anthropomorphic simulators reference in the seated position to represent more realistic positions can thus be used in studies in medical and occupational dosimetry as well as the importance of developing as realistic simulators as possible to dose estimation as faithful as possible in different irradiation scenarios. / Estabelecer limites à exposição da população a diversas fontes de radiação ionizante é de fundamental importância para prevenir indivíduos, ocupacionalmente expostos e do público, dos seus efeitos deletérios. Em âmbito computacional, é necessário que diferentes cenários de exposição sejam simulados, visando à obtenção dos coeficientes de dose (CCs), que associam grandezas dosimétricas físicas – como dose absorvida, fluência ou kerma no ar – com grandezas limitantes – como equivalente e/ou dose efetiva. Em certas condições de exposição a posição do indivíduo nem sempre é a mesma, e o cenário deve ser descrito da forma mais realística possível. Neste trabalho, os simuladores antropomórficos de referência da publicação nº 110 da ICRP, AM (Adult Male) e AF (Adult Female), tiveram suas posturas modificadas da postura supinada (em pé) para a postura sentada. A mudança de postura foi realizada por meio de uma subrotina escrita no software Visual Monte Carlo (VMC) para rotacionar a região da coxa dos simuladores e posicioná-la entre a região da perna e do tronco. O software ScionImage foi utilizado para reconstruir e suavizar os contornos no joelho e quadril dos simuladores na postura sentada, e com ferramenta auxiliar para visualização 3D dos simuladores foi utilizado o software VolView. Após essa etapa foi utilizado o código de transporte de radiação MCNPX para o cálculo dos coeficientes de conversão (CCs) de dose equivalente e efetiva por fluência de partículas, calculados para seis geometrias de irradiação AP, PA, LLAT, RLAT, ROT e ISO, recomendadas pela ICRP. Os resultados foram comparados entre os simuladores em pé e sentado, para ambos os gêneros, com o objetivo de avaliar as diferenças de espalhamento e absorção da radiação para as diferentes posturas. Os resultados dos CCs mostram diferenças significativas, de até 100 % para dose equivalente dos órgãos situados a região pélvica e 79 % em órgãos com distribuição em todo o corpo como, por exemplo, pele, músculo, nódulos linfáticos medula óssea e trabécula óssea, e uma diferença de 14 % para dose efetiva. Ademais, a fim de realizar um estudo comparativo entre dois tipos de simuladores, foi estimado os CCs de dose equivalente e efetiva dos simuladores híbridos adulto masculino, UFHADM, e feminino, UFHADF, na postura sentada, e comparado com os simuladores AM e AF, também na postura sentada, onde foi observado diferença significativa em energias abaixo de 0,05 MeV. Este estudo demonstrou a viabilidade do uso dos simuladores antropomórficos de referência na postura sentada para representar posturas mais realísticas podendo assim, ser utilizado em estudos na dosimetria médica e ocupacional, bem como a importância de desenvolver simuladores tão realista quanto possíveis para estimativa de dose tão fiéis quanto possíveis em diversos cenários de irradiação.

Page generated in 0.0362 seconds