• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 55
  • 1
  • Tagged with
  • 56
  • 44
  • 41
  • 38
  • 34
  • 16
  • 15
  • 15
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação in vitro da biocompatibilidade de resinas acrílicas para base de próteses e materiais reembasadores resilientes /

Chaves, Carolina de Andrade Lima. January 2013 (has links)
Orientador: Ana Lúcia Machado / Co-orientador: Carlos Alberto de Souza Costa / Banca: Ana Carolina Pero Vizoto / Banca: João Neudenir Arioli Filho / Banca: Cláudia Helena Lovato da Silva / Banca: Renata Cunha Matheus Rodrigues Garcia / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de 3 resinas acrílicas (RA) para bases de prótese sendo duas polimerizadas por energia de microondas (Vipi Wave-VW e Nature Cryl-NC) e uma fotoativada (Eclipse-E); e a biocompatibilidade de materiais reembasadores resilientes (MRR), sendo 2 à base de silicone (Ufi Gel P e Sofreliner S), 2 à base de resina acrílica (Durabase Soft e Trusoft) e 2 condicionadores de tecidos (Softone e Coe Comfort) por meio de análises do metabolismo celular, da morfologia celular, do padrão de morte celular, da proliferação celular e da expressão do fator de crescimento TGFß 1, da integrina α5ß1 e de citocinas. A análise das RA foi realizada com células L929; para os MRR, as análises foram realizadas utilizando-se células L929, e/ou HaCaT e/ou RAW 264,7. Os resultados obtidos foram submetidos à análise estatística, realizada ao nível de significância de 5%. Todos os materiais quando testados com eluatos não apresentaram efeitos citotóxicos, e quando testados em contato direto (MTT e azul de alamar) alteraram significativamente a viabilidade celular, tendo sido os menores valores observados para o material NC quando comparado ao E. Para os materiais reembasadores o T, S e C. Maior taxa de necrose e apoptose foram observadas para os eluatos de todos os materiais quando avaliados no período de 24 horas; além disso, foi demonstrado que os materiais avaliados podem desencadear a expressão do TGFß 1, da integrina α5ß1 e de proteínas inflamatórias (fator de necrose tumoral - TNF-α, da citocina IL-1ß e de 5 quimiocinas: CCL2, CCL3, CCL5, CXCL2 e CXCL4). Sendo assim, de acordo com as limitações do presente estudo, pode-se concluir que a resina Nature Cryl resultou em menor viabilidade celular que a resina Eclipse e que os materiais Ufi Gel P e Sofreliner S apresentaram, em geral, melhor bicompatibilidade dentre os materiais reembasadores resilientes avaliados. / Abstract: The aim of this study was to evaluate the cytotoxicity of 3 denture base acrylic resins with different polymerization methods (Eclipse, Vipi Wave and Nature Cryl) and the biocompatibility of soft lining materials, 2 silicone-based (Ufi Gel P and Sofreliner S), 2 acrylic-based (Durabase Soft and Trusoft) and 2 tissue conditioners (Softone and Coe Comfort), by analysing cell metabolism, cell morphology, pattern of cell death, cell proliferation and expression of growth factor TGFß 1, integrin α5ß1 and cytokines. For the acrylic resins, analyses were made with L929 cells, while for the resilient lining materials, analyzes were performed using L929, and/or HaCaT and/or RAW 264.7 cells. Results were statistically analyzed, at a significance level of 5%. The 24 and 48-h eluates from all materials were not cytotoxic to the cells. For the direct contact tests (MTT and Alamar Blue), a significant effect on cell viability was found, with the lowest values observed for materials NC when compared with E and between the reliners Trusoft, Softone and Coe Comfort. For all materials, increased rate of necrosis and apoptosis were observed for the 24 hs eluates. It was also demonstrated that all materials tested can trigger the expression of TGFß 1, α5ß1 integrin and inflammatory proteins (tumor necrosis factor -TNF-α, cytokine IL-1ß and 5 chemokines- CCL2, CCL3, CCL5, CXCL2 and CXCL4). Thus, within the limitations of this study, it can be concluded that the denture base acrylic resin Nature Cryl resulted in lower cell viability compared to the Eclipse resin and that the materials Ufi Gel P and Sofreliner S showed better biocompatibility among the soft liner materials evaluated. / Doutor
12

Avaliação dos elementos finitos de tensões no tecido ósseo peri-implantar durante a osseointegração / Finite element analysis of stresses in peri-implant bone tissue during osseointegration

Santos, Mateus Bertolini Fernandes dos, 1985- 02 September 2011 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T13:50:15Z (GMT). No. of bitstreams: 1 Santos_MateusBertoliniFernandesdos_D.pdf: 5044188 bytes, checksum: b81a4d5dccdc37cad705fb6ddaf4b97c (MD5) Previous issue date: 2011 / Resumo: Forças aplicadas por próteses totais a implantes submersos durante o período deosseointegração podem, em alguns casos, levar ao insucesso clínico. Até o momento não existe trabalho na literatura que quantifique e/ou verifique a distribuição das forças mastigatórias em implantes submersos durante a ação mastigatória de próteses totais convencionais usadas provisoriamente durante o período de osseointegração. Dessa forma, neste trabalho foram avaliadas as tensões geradas no tecido ósseo subjacente a implantes recém-colocados, em diferentes situações, durante a ação mastigatória em próteses totais convencionais provisórias inferiores, por meio da metodologia dos elementos finitos. Com software de modelagem 3-D (SolidWorks 2010, SolidWorks Corp., Concord, Massachusetts, EUA) foram confeccionados modelos tridimensionais de mandíbula simulando diferentes situações clínicas: (1) implantes submersos, próteses totais convencionais e próteses reembasadas com diferentes materiais reembasadores macios; (2) diferentes níveis de altura de exposição dos cicatrizadores (submerso, nível gengival, 1,5 mm exposto no meio bucal); e (3) diferentes espessuras e comparação entre reembasamento na base da prótese inteira ou somente na região dos implantes. As análises foram realizadas em software específico (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) e para cada modelo foram simuladas duas situações, com aplicação de carga mastigatória em canino inferior direito (35N) e primeiro molar inferior direito (50N). Todas as análises foram realizadas em tensão máxima principal, em MPa. Os resultados obtidos demonstraram que o reembasamento da prótese com material macio reduziu a concentração de tensões no tecido ósseo peri-implantar, sendo a concentração de tensão diretamente relacionada com a maciez do material. Os cicatrizadores submersos foram os que apresentaram menor valor de concentração de tensões. A espessura e área de reembasamento estão relacionadas à transmissão de tensões ao osso peri-implantar, quando o reembasamento da região dos implantes com espessura de 3 mm apresentou melhores resultados. Comparando-se os resultados mostrados nas diferentes simulações conclui-se que a situação que promoveu menor concentração de tensões no osso peri-implantar foi com implantes submersos, reembasamento realizado somente na região dos implantes, espessura de 3 mm e material macio. / Abstract: Forces applied to submerged implants from complete dentures during the osseointegration period can, in some cases, lead to clinical failure. To date there is no study in the literaturethat quantifies and/or verifies the stress distribution of occlusal forces in submerged implants during the masticatory function of conventional complete dentures used on an interim basis during the period of osseointegration. Thus, this study evaluated the stresses in the bone adjacent to newly placed implants during the masticatory function in conventional complete dentures through the finite element methodology. Using a 3-D modeling software (SolidWorks 2010, SolidWorks Corp., Concord, Massachussets, EUA) it were made tridimensional models of a mandible simulating different clinical situations: (1) submerged implants, conventional complete dentures and relined ones with different soft liner materials; (2) different height levels of exposure to the oral environment (submerged, gingival level and 1.5mm of exposure to the oral environment); and (3) different thickness and comparation between relining the entire base or only in the region near the implants. The analysis were made in a specific software (ANSYS Workbench 12, Ansys Inc., Canonsburg, Pennsylvania, EUA) and for each model it were simulated two situations with masticatory load in inferior right canine (35N) and inferior right first molar (50N). All the analysis were made in maximum principal stress, in MPa. The obtained results showed that relined dentures with soft liner material reduced the stress concentration in the peri-implant bone tissue, being the stress concentration directly related to the softness of the material. Submerged implants presented the lowest values of stress concentration in the peri-implant bone tissue. The thickness and the area of reline are related to the transmission of stress to the peri-implant bone tissue, when relining the denture only in the region of the implants with a 3-mm thick layer of soft liner material presented better results. Comparing the results obtained from the different simulations it is possible to conclude that the situation which promoted fewer stress concentration in the peri-implant bone was with submerged implants, relining made only in the implants region, thicker layer (3 mm) of reline and softer material. / Doutorado / Protese Dental / Doutor em Clínica Odontológica
13

Padronização da metodologia para análise de sorção de água e solubilidade de materiais resilientes temporários para  base de prótese / Standardization of methodology for water sorption and solubility analysis of temporary resilient denture liners

Janaina Gomes Maciel 08 June 2016 (has links)
Não existem normas internacionais que determinem limites aceitáveis de sorção de água e solubilidade para os materiais resilientes temporários para base de prótese, além de haver divergências metodológicas nos estudos. Objetivou-se avaliar de forma padronizada essas propriedades físicas para materiais macios de curta duração ao longo de sua vida útil. Corpos de prova (50mm x 0,5mm/ ISO-10139-2) de 7 condicionadores teciduais (Coe-Comfort-CC, Softone-ST, Rite-Line-RL, Dura Conditioner-DC, Hydro-Cast-HC, DentusoftDS e Visco-gel-VG) e 2 reembasadores resilientes temporários (Trusoft-TS e Coe-Soft-CS) foram individualmente confeccionados e submetidos à dessorção até estabilização das massas. Então, foram imersos em água destilada a 37oC por 3, 5, 7 ou 14 dias (n=10) para depois serem pesados, dessecados e pesados novamente. Os dados foram obtidos em porcentagens de sorção/solubilidade e analisados estatisticamente por ANOVA 2 fatores e teste de Tukey HSD (&#x3B1;=0,05). Em todos os períodos, VG (12,06±0,93 a 16,62±0,87%) apresentou a maior sorção de água dentre os materiais testados, sendo as menores porcentagens observadas para CC (2,23±0,53 a 2,99±0,49%) (P<0,05). CC, CS e TS não apresentaram alteração significativa da sorção de água ao longo de 14 dias (P>0,05). Já os demais materiais exibiram um aumento significativo da sorção de água entre os períodos de 7 e 14 dias (P<0,05). Para a solubilidade, valores médios inferiores e estatisticamente semelhantes foram apresentados pelos materiais DC, HC, DS, TS, RT e CS (0,28±0,30 a 2,13±0,23%) (P>0,05). ST (4,09±1,60 a 8,80±1,15%) demonstrou maior solubilidade que CC (1,89±0,30 a 3,35±0,70%), mas os mais altos valores percentuais dentre os materiais testados foram observados para VG (20,30±4,26 a 23,59±20,24%) (P<0,05). CC, DC, DS, HC, RT, TS e CS não apresentaram alterações na solubilidade percentual média ao longo dos 14 dias de avaliação. Já os condicionadores teciduais VG e ST exibiram aumento dos valores médios apenas aos 14 dias de imersão em água. Conclui-se que, ao longo da vida útil média de um condicionador tecidual (7 dias), os materiais CC, DC, HC, DS, RL, CS e TS apresentaram comportamento in vitro satisfatório em relação à sorção de água e solubilidade. De acordo com os resultados obtidos, os materiais CC, TS e CS foram considerados os mais indicados dentre os testados para reembasamento de próteses em até 14 dias. / There are no international standards that determine acceptable limits of water sorption and solubility for the temporary resilient liners, besides the differences in the methodology of the studies. It was aimed to evaluate in a standardized manner these physical properties of short-term soft materials throughout their lifespan. Specimens (50mm x 0.5mm/ ISO-10139-2) of 7 tissue conditioners (Coe-Comfort-CC, Softone- ST, Rite-Line-RL, Dura Conditioner-DC, Hydrocast-HC, Dentusoft-DS and Visco-gel- VG) and 2 temporary resilient liner (Trusoft-TS e Coe-Soft-CS) were individually prepared and submitted to desorption until mass stabilization. Afterwards, they were immersed in distilled water at 37oC for 3, 5, 7, or 14 days (n=10) to then be weighed, dried and reweighed. The data were obtained in percentages of sorption/solubility and statistically analyzed by 2-way ANOVA and Tukeys test (&#x3B1;=0.05). In all periods, VG (12.06±0.93 to 16.62±0.87%) showed the highest water sorption among the tested materials, with the lowest percentages observed for CC (2.23±0.53 to 2.99±0.49%) (P<0.05). CC, CS and TS showed no significant changes in water sorption over 14 days (P>0.05). The other materials exhibited a significant increase in water sorption between the periods of 7 and 14 days (P<0.05). For the solubility, lower (and statistically similar to each other) values were presented by DC, HC, DS, TS, RT, and CS materials (0.28±0.30 to 2.13±0.23%) (P>0.05). ST (4.09±1.60 to 8.80±1.15%) showed higher solubility than CC (1.89±0.30 to 3.35± 0,70%), but the highest percentages among tested materials were observed for VG (20.30±4.26 to 23.59±20.24%) (P<0.05). CC, DC, DS, HC, RT, TS, and CS showed no changes in the mean percentage solubility throughout the 14-day trial. The tissue conditioners VG and ST exhibited increased average values only at 14 days of water immersion. It was concluded that, over the lifespan of a tissue conditioner (7 days), the materials CC, DC, HC, DS, RL, CS, and TS presented suitable in vitro performance with respect to water sorption and solubility. According to the results, the materials CC, TS, and CS were considered best suited among the tested materials for denture relining of up to 14 days.
14

Análise da transmissão e distribuição de tensões aplicadas em próteses totais convencionais reembasadas com diferentes espessuras de forrador macio / Analysis of Transmission and Distribution Voltages Applied to the Conventional Denture relined with a liner Soft

Lima, Juliana Bisinotto Gomes 08 July 2011 (has links)
Os materiais resilientes ou macios para reembasamento de base de próteses são utilizados na clínica odontológica com a finalidade de proporcionar maior conforto e eficiência mastigatória aos pacientes que utilizam próteses removíveis totais e que por situações específicas não suportam uma prótese removível total convencional com base rígida. Atualmente é muito utilizado nas próteses removíveis transicionais, para minimizar as pressões sobre implantes que se encontram na fase de osseointegração, além de proporcionar ausência de lesões traumáticas e condicionamento tecidual durante o período pós-cirúrgico; em casos de rebordo alveolar atrofiado; irritação crônica superficial possivelmente devido à pressão do forame mentoniano; rebordo em lâmina de faca; após radiação terapêutica dissipando as forças oclusais, entre outras. Assim, é objetivo deste estudo analisar por meio do método de elementos finitos tridimensional a distribuição de tensões aplicadas na prótese removível total reembasada com forradores macios em diferentes espessuras e consequente transmissão a mucosa e ao rebordo, definindo a espessura ideal de material reembasador. Os corpos-de-prova constituirão-se em modelos projetados de mandíbula desdentada com uma prótese total apoiada sobre o rebordo. São 6 modelos: modelo 1: prótese removível total apoiada diretamente sobre o rebordo sem material reembasador (caso controle); modelo 2: prótese removível total reembasada com 0,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 3: prótese removível total reembasada com 1mm de espessura de material reembasador apoiada sobre o rebordo; modelo 4: prótese removível total reembasada com 1,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 5: prótese removível total reembasada com 2,0mm de espessura de material reembasador apoiada sobre o rebordo; modelo 6: prótese removível total reembasada com 2,5mm de espessura de material reembasador apoiada sobre o rebordo. Uma força de 60N foi aplicada ao longo eixo dos dentes das próteses, sendo de mesma intensidade bilateralmente e simultaneamente. Após a execução dos teste e análise dos resultados verifica-se que a adição de apenas 0,5 mm de material reembasador (modelo 2), diminuiu em 10% o pico de tensão, ocorrendo diminuições menores com o aumento gradual da espessura de material reembasador. Dentro das características do presente trabalho, a diminuição dos picos são menores do que 1% entre os modelos 4 e 5, sugerindo que para mandíbulas com boa adaptação da prótese, superfície óssea lisa, sem espículas, nichos dentários ou outros fatores semelhantes, não é significativo uma espessura maior do que 1,5 mm de material reembasador . Um resultado que sai desse padrão se refere ao modelos 5 e 6, onde o aumento de 2 para 2,5 mm de espessura do material reembasador promoveu um aumento nos picos de tensão. Diante das características in vitro deste estudo conclui-se que uma espessura de 2mm de material reembasador é o suficiente para amortecer as forças mastigatórias. No presente estudo, espessura maior que 2mm promoveu tensões à mucosa e ao rebordo. / The soft or resilient materials for relining denture base are used in clinical dentistry in order to provide greater comfort and chewing efficiency of patients which use removable dentures for total and specific situations as they does not tolerate a removable prosthesis with total conventional rigid base. Currently it is widely used in transitional dentures, to minimize the pressures on implants in process of osseointegration, while providing no traumatic injuries and conditioning tissue during the postoperative period, in cases of atrophic alveolar ridge; superficial chronic irritation possibly due to pressure from the mental foramen, edging knife blade, and after radiation therapy dissipating occlusal forces. The aim of this study is to analyze through the three-dimensional finite element stress distribution applied in full removable denture rebased with soft liners in different thicknesses and consequent transmission to the mucosa and the edge, setting the ideal thickness of relining. The samples used in test form in models designed for edentulous mandible with a denture resting on the edge. There are 6 models: Model 1: Full removable denture supported directly on the alveolar ridge without relining (case control), Model 2: Full removable denture rebased with 0.5 mm thick relining resting on the alveolar ridge; Model 3: total removable prosthesis rebased with 1mm thickness relining resting on the alveolar ridge; Model 4: Full removable denture rebased with 1.5 mm thick relining resting on the alveolar ridge; Model 5: Full removable denture rebased with 2.0 mm thick relining resting on the alveolar ridge; Model 6: Full removable denture rebased with 2.5 mm thick supported on relining the alveolar ridge. A force of 60N was applied to the long axis of the tooth prosthesis, with the same intensity bilaterally and simultaneously. After execution of test and analysis of results shows that the addition of only 0.5 mm relining (model 2), down 10% peak tension, smaller decreases occurred with the gradual increase of the thickness of relining. Among the features of the present study, the decrease of the peaks are less than 1% between sections 4 and 5, suggesting that mandibles with good adaptation to the prosthesis, bone surface smooth, without spines, teeth or niches other similar factors, it is not a significant thickness greater than 1.5 mm relining. A result that comes out of this pattern refers to models 5 and 6, where the increase of 2 to 2.5 mm thick relining promoted an increase in spikes. The features of this in vitro study concluded that a thickness of 2mm relining is enough to absorb chewing forces. In this study, thickness greater than 2mm must transfer tension to the mucosa and alveolar ridge.
15

Análise da transmissão e distribuição de tensões aplicadas em próteses totais convencionais reembasadas com diferentes espessuras de forrador macio / Analysis of Transmission and Distribution Voltages Applied to the Conventional Denture relined with a liner Soft

Juliana Bisinotto Gomes Lima 08 July 2011 (has links)
Os materiais resilientes ou macios para reembasamento de base de próteses são utilizados na clínica odontológica com a finalidade de proporcionar maior conforto e eficiência mastigatória aos pacientes que utilizam próteses removíveis totais e que por situações específicas não suportam uma prótese removível total convencional com base rígida. Atualmente é muito utilizado nas próteses removíveis transicionais, para minimizar as pressões sobre implantes que se encontram na fase de osseointegração, além de proporcionar ausência de lesões traumáticas e condicionamento tecidual durante o período pós-cirúrgico; em casos de rebordo alveolar atrofiado; irritação crônica superficial possivelmente devido à pressão do forame mentoniano; rebordo em lâmina de faca; após radiação terapêutica dissipando as forças oclusais, entre outras. Assim, é objetivo deste estudo analisar por meio do método de elementos finitos tridimensional a distribuição de tensões aplicadas na prótese removível total reembasada com forradores macios em diferentes espessuras e consequente transmissão a mucosa e ao rebordo, definindo a espessura ideal de material reembasador. Os corpos-de-prova constituirão-se em modelos projetados de mandíbula desdentada com uma prótese total apoiada sobre o rebordo. São 6 modelos: modelo 1: prótese removível total apoiada diretamente sobre o rebordo sem material reembasador (caso controle); modelo 2: prótese removível total reembasada com 0,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 3: prótese removível total reembasada com 1mm de espessura de material reembasador apoiada sobre o rebordo; modelo 4: prótese removível total reembasada com 1,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 5: prótese removível total reembasada com 2,0mm de espessura de material reembasador apoiada sobre o rebordo; modelo 6: prótese removível total reembasada com 2,5mm de espessura de material reembasador apoiada sobre o rebordo. Uma força de 60N foi aplicada ao longo eixo dos dentes das próteses, sendo de mesma intensidade bilateralmente e simultaneamente. Após a execução dos teste e análise dos resultados verifica-se que a adição de apenas 0,5 mm de material reembasador (modelo 2), diminuiu em 10% o pico de tensão, ocorrendo diminuições menores com o aumento gradual da espessura de material reembasador. Dentro das características do presente trabalho, a diminuição dos picos são menores do que 1% entre os modelos 4 e 5, sugerindo que para mandíbulas com boa adaptação da prótese, superfície óssea lisa, sem espículas, nichos dentários ou outros fatores semelhantes, não é significativo uma espessura maior do que 1,5 mm de material reembasador . Um resultado que sai desse padrão se refere ao modelos 5 e 6, onde o aumento de 2 para 2,5 mm de espessura do material reembasador promoveu um aumento nos picos de tensão. Diante das características in vitro deste estudo conclui-se que uma espessura de 2mm de material reembasador é o suficiente para amortecer as forças mastigatórias. No presente estudo, espessura maior que 2mm promoveu tensões à mucosa e ao rebordo. / The soft or resilient materials for relining denture base are used in clinical dentistry in order to provide greater comfort and chewing efficiency of patients which use removable dentures for total and specific situations as they does not tolerate a removable prosthesis with total conventional rigid base. Currently it is widely used in transitional dentures, to minimize the pressures on implants in process of osseointegration, while providing no traumatic injuries and conditioning tissue during the postoperative period, in cases of atrophic alveolar ridge; superficial chronic irritation possibly due to pressure from the mental foramen, edging knife blade, and after radiation therapy dissipating occlusal forces. The aim of this study is to analyze through the three-dimensional finite element stress distribution applied in full removable denture rebased with soft liners in different thicknesses and consequent transmission to the mucosa and the edge, setting the ideal thickness of relining. The samples used in test form in models designed for edentulous mandible with a denture resting on the edge. There are 6 models: Model 1: Full removable denture supported directly on the alveolar ridge without relining (case control), Model 2: Full removable denture rebased with 0.5 mm thick relining resting on the alveolar ridge; Model 3: total removable prosthesis rebased with 1mm thickness relining resting on the alveolar ridge; Model 4: Full removable denture rebased with 1.5 mm thick relining resting on the alveolar ridge; Model 5: Full removable denture rebased with 2.0 mm thick relining resting on the alveolar ridge; Model 6: Full removable denture rebased with 2.5 mm thick supported on relining the alveolar ridge. A force of 60N was applied to the long axis of the tooth prosthesis, with the same intensity bilaterally and simultaneously. After execution of test and analysis of results shows that the addition of only 0.5 mm relining (model 2), down 10% peak tension, smaller decreases occurred with the gradual increase of the thickness of relining. Among the features of the present study, the decrease of the peaks are less than 1% between sections 4 and 5, suggesting that mandibles with good adaptation to the prosthesis, bone surface smooth, without spines, teeth or niches other similar factors, it is not a significant thickness greater than 1.5 mm relining. A result that comes out of this pattern refers to models 5 and 6, where the increase of 2 to 2.5 mm thick relining promoted an increase in spikes. The features of this in vitro study concluded that a thickness of 2mm relining is enough to absorb chewing forces. In this study, thickness greater than 2mm must transfer tension to the mucosa and alveolar ridge.
16

Avaliação clínica e laboratorial de uma solução experimental para higiene de reembasador resiliente para prótese total / Clinical and laboratory evaluation of an experimental solution for hygiene of denture soft liners

Malheiros Segundo, Antonio de Luna 17 May 2011 (has links)
Este estudo avaliou a eficácia de métodos de higiene na remoção do biofilme da prótese total inferior reembasada com reembasador resiliente à base de silicone. Trinta pacientes tiveram suas próteses inferiores reembasadas (Mucopren soft) e, aleatoriamente, foram distribuídos em três grupos: A) Método mecânico escovação com dentifrício (Corega Brite) e escova (Johnson & Johnson) específicos para prótese total; B) Método químico imersão em solução à base de Ricinus communis; C) Método associado associação A+B. O período experimental foi de 60 dias e para a quantificação do biofilme, a superfície interna da prótese total inferior foi evidenciada (Fluoresceína sódica 1%) e fotografada, após 15, 30 e 60 dias de utilização dos métodos. As áreas, total da prótese e a corada (biofilme), foram mensuradas com o software Image Tool 3.0 e os resultados expressos em porcentagem. A análise microbiológica foi realizada pela técnica de hibridização DNA-DNA checkerboard. Para a avaliação qualitativa do material reembasador, às próteses foram atribuídos escores (0, 1 e 2) em função da apresentação do material após os períodos avaliados. Os testes estatístico iniciais indicaram a distribuição não normal ou homogênea dos dados, optando-se pela transformação dos mesmos em raiz quadrada de forma a aplicar estatística paramétrica. Quanto a quantificação do biofilme, empregou-se o teste Anova seguido pelo teste complementar de Tukey considerando P<0,05. Houve diferença significante entre os métodos (P=0,009) e períodos (P=0,003) avaliados. Não houve interação entre os fatores (P=0,5). O método mecânico apresentou a menor média de porcentagem de biofilme (1,45±1,03) se comparado ao químico (2,96±1,98) e associado (2,71±1,76). Após 60 dias (3,37±2,04), o acúmulo de biofilme foi maior que após 15 (1,28±0,77) e 30 (2,46±1,54) dias de utilização dos métodos. Para análise da eficácia antimicrobiana, foi empregado o método linear generalizado, não havendo interação entre os tempos e métodos de higiene. Entre estes, das 38 espécies estudadas, em 10 houve diferença estatística para, sendo que o método de imersão apresentou os valores mais baixos de contagem destes microorganismos. Apenas uma espécie apresentou diferença entre os períodos. Após a análise visual, verificou-se que o nível de deterioração foi menor após os 60 dias de análise nos materiais reembasadores higienizados por meio da escovação. As próteses higienizadas pelo método mecânico apresentaram a menor porcentagem de área de biofilme e o menor nível de degradação do reembasador. O método químico apresentou maior eficácia na diminuição de contagem de microorganismos, inclusive nas espécies de Candida. / The aim of this study was to evaluate the effectiveness of hygiene methods on biofilm removal of the lower denture relined with a silicone material. Thirty patients had their lower dentures relined (Mucopren soft) and randomly divided into three groups: A) Mechanical method brushing with toothpaste (Corega Brite) and toothbrush (Johnson) specific for complete dentures; B) Chemical method immersion in Ricinus communis based solution; C) Associate method association of A and B. The experimental period lasted 60 days and for the biofilm quantification, the internal surface of the lower denture was evidenced (Sodium fluorescein 1%) and photographed, after 15, 30 and 60 days of use of the prostheses. Total and evidenced (biofilm) area of the dentures were measured by the software Image Tool 3.0 and the results were expressed in percentages. Microbiological analysis was performed by the DNA-DNA checkerboard technique. For the qualitative evaluation of the soft liner, scores were attributed to the prostheses (0, 1 and 2) according to the presentation of the material after evaluation periods. After verification of distribution and homogeneity of data, it was found that the distribution was not normal or homogeneous, opting for transformation in square root in order to apply parametric statistics. For the biofilm quantification, Anova was employed followed by the Tukeys test considering P<0,05. There were significant difference between the methods (P=0,009) and periods (P=0,003) evaluated. There was no interaction between the factors (P=0,5). Mechanical method presented the lowest mean percentage of biofilm. (1,45±1,03) when compared to the chemical (2,96±1,98) and to the associated method (2,71±1,76). After 60 days (3,37±2,04), the accumulation of biofilm was greater than after 15 (1,28±0,77) and 30 (2,46±1,54) days of the methods use. To analyze the antimicrobial efficacy, the generalized linear method was used. The test showed no interaction between periods and groups. Between groups, 10 of the 38 species evaluated presented statistical difference; and the immersion method showed the lowest counting values of those microorganisms. Only one specie presented statistical difference between the periods. After the visual analysis, it was found that the level of the dentures cleaned by the mechanical method exhibited the lowest percentage of biofilm area and presented the lowest level of degradation of the liner. The chemical method was more efficient in reducing the count of bacteria, including the Candida spp.
17

Efeito do armazenamento em água sobre a citotoxicidade de materiais resilientes para base de próteses. / Efect of water storage on the cytotoxicity of resilient liners

Jon, Lidia Yileng Tay Chu 24 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:12Z (GMT). No. of bitstreams: 1 Lidia Yileng Tay Chu Jon.pdf: 1011394 bytes, checksum: 9cfa95ca6ba9d9c4b6cb8db597101aa8 (MD5) Previous issue date: 2010-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to evaluate the effect of water storage time and of a heat treatment on the cytotoxicity of soft lining denture material using the 3H-thymidine incorporation test. Sample disks (10 mm X 1 mm) of soft lining denture Dentusoft, Dentuflex, Trusoft, Ufi Gel P and of denture base acrylic resin Lucitone 550 were fabricated under aseptic conditions. Twelve specimens of each material were prepared and divided into four groups: GN: The specimens received no treatment or storage in water, G24: The specimens were stored in distilled water at 37°C for 24 hours; G48: The specimens were stored in distilled water at 37°C for 48 hours, GHW: The specimens were immersed in water at 55 °C for 10 minutes. To analyze the cytotoxic effect, three samples of each experimental group were placed in test tubes with 9 ml of DMEM's medium supplemented and incubated at 37 °C for 24 hours. During this incubation period, the toxic substances were broadcast to the culture medium, forming the extracts that were used for the cytotoxicity test. The cytotoxicity of each material was analyzed quantitatively by the incorporation of radioactivity 3H - thymidine by checking the number of viable cells for the synthesis of DNA. The results of DNA synthesis were subjected to analysis of variance in a factorial two-way (material and storage time in water). Comparing the averages of cell viability with the classification of cytotoxic established by ISO 10993-5, it was found that Ufi Gel P had non-cytotoxic effect, Trusoft had slightly cytotoxic effect, Dentuflex had a moderated cytotoxic effect, all in any experimental condition. It was also observed that the Dentusoft alternated between slightly cytotoxic and non-cytotoxic effect because their average viability ranged around 75% and Lucitone 550 had non-cytotoxic effect when stored in water for 48 hours, but the others had around 50% cell viability, the slightly moderated cytotoxic effect. It is concluded that the soft lining denture based in acrylic resin had a slightly and moderated cytotoxic effect, Ufi Gel P, the silicone based soft liner, was not cytotoxic; the effect of water storage after 24 hours or 48 hours and the heat treatment did not reduce the cytotoxicity effect of soft lining denture materials. / O objetivo deste estudo foi avaliar, por meio do teste quantitativo de incorporação de 3H-timidina, a citotoxicidade de materiais reembasadores resilientes em função do tempo de armazenamento em água e em função de um tratamento térmico. Doze corpos-de-prova de cada material reembasador resiliente (Dentusoft, Dentuflex, Trusoft e Ufi Gel P) e da resina termopolimerizável (Lucitone 550) foram confeccionados de forma asséptica em forma de discos e divididos em 4 grupos: GN: os corpos-de-prova não receberam nenhum tipo de tratamento ou armazenamento; G24: os corpos-de-prova foram armazenados em água destilada à 37ºC por 24 horas; G48: os corpos-de-prova foram armazenados em água destilada à 37ºC por 48 horas; GAQ: os corpos-de-prova foram imersos em água a 55°C por 10 minutos. Para a análise do efeito citotóxico, três corpos-de-prova de cada grupo experimental foram colocados dentro de tubos de ensaio com 9 mL de meio de cultura DMEM suplementado e incubados a 37ºC por 24 horas. Durante esse período, as substâncias tóxicas foram difundidas para o meio de cultura, formando os extratos que foram utilizados no teste de citotoxicidade. Esta foi analisada quantitativamente por meio da incorporação do radioisótopo 3H-timidina, verificando o número de células viáveis pela síntese de DNA. Os resultados foram submetidos à análise de variância em esquema fatorial de dois fatores incluindo ainda um grupo controle, ao nível de 5% de significância. Confrontando-se as médias obtidas de viabilidade celular com a classificação do efeito citotóxico estabelecida pela ISO 10993-5, verificou-se que o Ufi Gel P foi considerado não-citotóxico, o Trusoft levemente citotóxico e o Dentuflex discretamente citotóxico, em qualquer condição experimental. Observou-se também que o Dentusoft alternou entre levemente citotóxico e não-citotóxico porque suas médias de viabilidade variaram em torno de 75% e o Lucitone 550 apresentou efeito não-citotóxico quando armazenado em água por 48 horas, mas as outras médias ficaram em torno de 50% de viabilidade celular, entre levemente-citotóxico e discretamente citotóxico. Concluiu-se que os reembasadores resilientes a base de resina acrílica (Trusoft e Dentuflex) foram classificados como levemente citotóxico e discretamente citotóxico, respectivamente. O condicionador de tecido (Dentusoft) alternou entre levemente citotóxico e não citotóxico e o reembasador resiliente a base de silicone (Ufi Gel P) não teve efeito citotóxico. O armazenamento em água ou o tratamento térmico não diminuiu a citotoxicidade dos reembasadores resilientes e o armazenamento em água reduziu a citotoxicidade da resina acrílica para base de prótese (Lucitone 550).
18

Efeito da imersão em soluções desinfetantes na capacidade de formação de biofilme de C.albicans e características topográficas de uma resina acrílica para base de prótese e um reembasador /

Amaya Arbeláez, Maria Isabel January 2016 (has links)
Orientador: Janaina Habib Jorge / Resumo: O presente estudo teve como objetivo avaliar a capacidade de formação de biofilme de Candida albicans sobre resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase Fast II) de próteses, após imersão diária por períodos de até 6 meses em soluções desinfetantes. Foram confeccionados 360 corpos de prova circulares de cada resina acrílica usando uma matriz metálica (14 x 1,2 mm). As amostras foram imersas overnight durante 0, 1, 3, e 6 meses em 5 soluções desinfetantes: hipoclorito de sódio 0,5%, perborato de sódio 3,8%, digluconato de clorexidina 2%, vinagre de maçã puro (Minhoto®) e água destilada (grupo controle). Após os diferentes períodos de imersão, um biofilme maduro de 48h de C. albicans (cepa ATCC 90028) foi formado sobre os corpos de prova. A capacidade de formação deste biofilme foi analisada utilizando o método de contagem de colônias (UFC/mL) e o ensaio de viabilidade celular Alamar Blue®. Para todos os grupos experimentais, imagens foram obtidas a partir de microscopia eletrônica de varredura (MEV) para avaliação das características topográficas das resinas após a imersão nos diferentes tempos. Todas os experimentos foram realizados em três ocasiões independentes. Análise de variância de três fatores (ANOVA) foi utilizada para avaliar o metabolismo celular (ensaio Alamar Blue®) e os valores de UFC/mL obtidos a partir da formação do biofilme de C. albicans. Foi adotado o nível de significância de 5%. Os resultados de Alamar Blue® mostraram um efeito... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
19

Avaliação eletromiográfica e análise da qualidade de vida de edentados totais antes e após o reembasamento das próteses inferiores / Electromyographic evaluation and oral health related quality of life of edentulous before and after mandibular denture relining

Pisani, Marina Xavier 30 May 2012 (has links)
O presente estudo teve como objetivo geral analisar o impacto do reembasamento de próteses totais com reembasadores rígido e macio na atividade eletromiográfica e na qualidade de vida relacionada à saúde oral (OHRQoL) de pacientes edentados totais. Quarenta e quatro usuários de próteses totais superiores e inferiores foram distribuídos em dois grupos. No grupo 1 (n=22), as próteses inferiores foram reembasadas com reembasador macio à base de silicone (Mucopren Soft) e no grupo 2, com reembasador rígido à base de resina acrílica (Kooliner) pela técnica direta. A avaliação eletromiográfica dos músculos masseter e temporal e análise da OHRQoL foram realizadas antes do reembasamento (baseline-T0) e após 90 dias (T90) da intervenção. Para avaliação da OHRQoL, foi aplicado o questionário OHIP-EDENT, composto por quatro domínios, e três possíveis respostas (escores) às questões: nunca (0), às vezes (1) e quase sempre (2). Após normalização do sinal eletromiográfico, os pacientes foram instruídos a realizarem a máxima contração voluntária em MIH (teste estático), e as variáveis consideradas foram: POC (%), tors (%) e total de atividade eletromiográfica ou impacto (&mu;V / &mu; V.s %). Em seguida, mastigaram amendoins, barra de cereal e chocolate (teste dinâmico), com as seguintes variáveis: coordenação neuromuscular (%), frequência (Hz) e impacto (&mu;V / &mu;V.s %). Os resultados foram analisados por meio do modelo linear generalizado (p&le;0,05). A comparação dos escores da OHRQoL indicou diferença significante entre T0 e T90, independente do grupo, representando uma melhoria nas questões relacionadas à mastigação (domínio 1; p=0,007), dor oral e desconforto (domínio 4; p= 0,047) e no OHIP em geral (p=0,025). Não houve diferença entre os grupos para nenhum dos domínios e para o OHIP em geral. Os resultados do POC dos músculos masseter e temporal não indicaram diferença significante entre os tempos (POCmas p=0,147; POCtem p=0,469) e entre os grupos (POCmas p=0,549; POCtem p=0,104). Para o tors, não foi encontrada diferença significante entre os grupos (p=0,971), e, houve redução do tors em T90 (p=0). Não houve diferença significante entre os grupos (p=0,067), para o impacto, que aumentou em T90 (p=0). A coordenação neuromuscular durante a mastigação de chocolate (p=0), barra de cereal (p=0) e amendoim (p=0) aumentou em T90 e não houve diferença significante entre os grupos (chocolate p=0,087; barra p=0,185; amendoim p=0,472). Não foi encontrada diferença significante entre os grupos (p=0,530) e tempos (p=0,685) para a frequência da mastigação de chocolate. Para o amendoim e barra de cereal, a frequência aumentou em T90 (amendoim p=0,03; barra p=0,007) e não houve diferença entre os grupos (amendoim p=0,566; barra p=0,173). O impacto, durante mastigação de chocolate, aumentou em T90 (p=0), onde o grupo rígido apresentou maior valor (p=0,018). Durante a mastigação de amendoim e barra de cereal, o impacto aumentou em T90 (amendoim p=0; barra p=0) e não houve diferença significante entre os grupos (amendoim p=0,428; barra p=0,590). Conclui-se que o reembasamento, promoveu aumento na atividade eletromiográfica dos músculos avaliados, bem como melhorias na função mastigatória e na OHRQoL. Para a maioria das variáveis não houve diferença significante entre os reembasadores macio e rígido. / The present study aimed to analyze the impact of denture relining with hard and soft denture liners in the electromyographic activity and oral health related quality of life (OHRQoL) of edentulous patients. Forty and four complete denture wearers were distributed in two groups. In group 1 (n=22), the mandibular dentures were relined with a soft silicone based liner (Mucopren Soft) and in group 2, with a hard acrylic based denture liner (Kooliner) by chairside procedures. The electromyography of masseter and temporal muscles and the OHRQoL analysis were assessed before relining (baseline-T0) and after 90 days (T90) of the intervention. The questionnaire OHIP-EDENT, that was used to evaluate the OHRQoL, is composed of four domains, and three possible answers (scores) to the questions: never (0), sometimes (1) and almost always (2). After the normalization of the electromyographic signal, patients had been instructed to perform the maximum voluntary contraction in MIH (static test), and the following variables were considered: POC (%), tors (%) and total of electromyographic activity or impact (&mu;V / &mu;V.s %). After that, they performed masticatory movements by chewing peanuts, cereal bar and chocolate (dynamic test), with the following variables: neuromuscular coordination (%), frequency (Hz) and impact (&mu;V / &mu;V.s %). The results were analyzed by means of the generalized linear model (p&le;0,05). The scores comparison of the OHRQoL indicated significant difference among T0 and T90, regardless the group, which represented an improvement in questions related to mastication (domain 1; p=0,007), oral pain and discomfort (domain 4; p= 0,047) and in overall OHIP (p=0,025). There was no significant difference between the groups for none of the domains and for the overall OHIP. Regarding POC of masseter and temporal, no significant differences between times (POCmas p=0,147; POCtem p=0,469) and groups (POCmas p=0,549; POCtem p=0,104) were found. For tors, significant difference between the groups was not found (p=0,971), and, it decreased in T90 (p=0). There was no significant difference between the groups (p=0,067), for the impact, which increased in T90 (p=0). The neuromuscular coordination during chocolate (p=0), cereal bar (p=0) and peanut (p=0) mastication increased in T90 and there was no significant difference between the groups (chocolate p=0,087; cereal p=0,185; peanut p=0,472). Significant difference between the groups (p=0,530) and times (p=0,685) for the frequency during chocolate mastication was not found. For peanut and cereal bar, the frequency increased in T90 (peanut p=0,03; cereal p=0,007) and there was no difference between the groups (peanut p=0,566; cereal p=0,173). The impact, during chocolate mastication, increased in T90 (p=0), and the hard group presented higher values than the soft (p=0,018). For peanut and bar of cereal mastication, the impact increased in T90 (peanut p=0; bar p=0) and there was no significant difference between the groups (peanut p=0,428; bar p=0,590). It can be concluded that the relining increased the electromyographic activity of the evaluated muscles and improved the masticatory function and the OHRQoL. There was no significant differences among the hard and soft denture liners for most of the tested variables.
20

Solução efervescente para higiene de próteses totais: influência na sorção de água, solubilidade, dureza e na alteração de cor de reembasadores / Effervescent solutions for denture hygiene: Influence in water sorption, solubility, hardness and color changes of denture liners

Malheiros Segundo, Antonio de Luna 18 December 2007 (has links)
Este estudo avaliou propriedades físicas de materiais reembasadores para dentaduras após imersão em solução à base de perborato de sódio. Em todos os testes, os materiais, Kooliner e Elite Soft foram divididos nos grupos G1 (controle): imersão em saliva artificial a 37°C e G2 (experimental): imersões diárias em solução à base de perborato de sódio (Corega Tabs) por 5 minutos. Para os testes de sorção, solubilidade, alteração de cor e de dureza, foram obtidos 30 espécimes em forma de disco (15x3mm) de cada material, por meio da técnica direta, a partir da prensagem do material em matriz metálica vazada entre duas placas de vidro. A sorção e solubilidade foram avaliadas após 120 dias de imersão. A alteração de cor foi avaliada imediatamente após o acabamento dos corpos-de-prova e após 30 e 120 dias. A dureza dos materiais foi mensurada inicialmente, após 30 e 60 dias de imersão. O teste de Kruskal-Wallis (P<0,05) indicou que para o material Kooliner, o tipo de imersão (G1=1,43; G2=1,63) não interferiu nos valores de sorção. Quanto ao Elite soft, o perborato de sódio (G1=0,29; G2=0,51) promoveu aumento significativo nos valores de sorção. Comparando os materiais, o Kooliner apresentou médias de sorção significativamente mais altas que o Elite soft, para os dois grupos estudados. Para solubilidade, o teste Anova (P<0,05) a dois fatores de variação indicou diferença significante entre o fator grupo e entre o fator material. O Kooliner (0,168) bem como o grupo 1(0,137) apresentaram as maiores médias de solubilidade em relação ao Elite soft (0,089) e o grupo 2 , respectivamente. Com relação à cor (Anova, P<0,05), os dois materiais sofreram alteração no intervalo de 30 (Kooliner: G1=3,63, G2=2,87; Elite soft: G1=6,27, G2=6,01) e 120 (Kooliner: G1=4,21, G2=3,94; Elite soft: G1=8,54, G2=9,23) dias de imersão. O fator grupo não influenciou nesta propriedade dos materiais. Para a dureza do Kooliner, foi aplicada a análise de variância a dois fatores de variação (grupo: G1=6,63; G2=7,27 e tempo: T0=5,24; T30=7,28; T60=8,34), que indicou diferença somente para o fator tempo. Após a comparação das médias (Tukey=0,87), notou-se aumento significante (P<0,05) da dureza entre todos os tempos avaliados. Os corpos-de-prova de Elite soft do grupo experimental (49,18) apresentaram um aumento (P<0,05) na dureza quando comparado ao grupo controle (48,72). Para o fator tempo, o teste de Tukey (0,76), indicou diferença significante (P<0,05) entre as três médias (T0=46,45; T30=49,63; T60=50,74). O perborato de sódio não influenciou de forma significante nas propriedades avaliadas neste estudo. Dentre os materiais, o Kooliner foi o que apresentou maior estabilidade, porém é um material com características diferentes do Elite soft. O tempo é um fator importantíssimo na alteração das propriedades dos materiais, tendo interferido em todas as variáveis testadas. Estudos com o objetivo de aprimorar as características dos materiais para uma aplicação a longo prazo devem ser ainda realizados, visando a viabilidade de uso dos materiais reembasadores. / The aim of this study was to evaluate the physical properties of denture liners after immersion in a sodium perborate´s solution. In all the tests, both materials, Kooliner and Elite soft, were divided into the groups G1 (control): immersion in artificial saliva at 37°C and G2 (experimental): daily immersions in a sodium perborates´s solution (Corega Tabs) for five minutes. Thirty specimens (diameter of 15 mm and thickness of 3 mm) were obtained for the tests of water sorption, solubility, color change and hardness. Each material was processed according to the manufacturer´s directions in metallic moulds prepared for this purpose and compressed by two glass plates. Water sorption and solubility were evaluated after 120 of immersion. Color change was evaluated after specimens´ finishing, after thirty and sixty days of immersion. Kruskal Wallis (P<0,05) indicated that the immersion in sodium perborate (G1=1,43; G2=1,63) did not interfere in the water sorption values. Sodium perborate promoted significative raise in the Elite soft´s water sorption (G1=0,29; G2=0,51). Comparing the materials, Kooliner had the biggest means in both groups. In the solubility test, ANOVA (P<0,05), using two variation factors, indicated signifficant difference between groups and materials. Kooliner (0,168) and Group 1 (0,137) presented the biggest solubility means when compared with Elite soft (0,089) and Group 2 (0,110). Both materials changed between 30 (Kooliner: G1=3,63, G2=2,87; Elite soft: G1=6,27, G2=6,01) and 120 (Kooliner: G1=4,21, G2=3,94; Elite soft: G1=8,54, G2=9,23) days of immersion in the color test (Anova, P<0,05). To the Kooliner´s hardness, the ANOVA with two variation factors, indicated signifficant differece only for the time of immersion (grupo: G1=6,63; G2=7,27 e tempo: T0=5,24; T30=7,28; T60=8,34). Comparing the means (Tukey=0,87) a signifficant raise (P<0,05) of the hardness was observed between all the periods evaluated. Specimens of the experimental group of Elite soft (49,18) showed a raise (P<0,05) in the hardness when compared to the control group (48,72). The test of Tukey (0,76) indicated significant difference (P<0,05) in the time of immersion between the three means (T0=46,45; T30=49,63; T60=50,74). Sodium perborate did not influence significantly the properties evaluated in this study. Between the materials, Kooliner presented the best stability. But both materials have different compositions and behave in different ways clinically. The period of immersion is a very important factor in the physical properties of the materials; and all of them presented signifficant differences during this period. Studies with the intention of improving the materials´ properties for a long term use should be tried to make viable the use of denture liners.

Page generated in 0.0667 seconds