• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 210
  • 210
  • 112
  • 105
  • 89
  • 68
  • 45
  • 33
  • 28
  • 25
  • 24
  • 23
  • 23
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Influência da pigmentação, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial /

Haddad, Marcela Filié. January 2013 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Adriana Cristina Zavanelli / Banca: Cláudia Helena Lovato da Silva / Banca: Marcelo Ferraz Mesquita / Resumo: Próteses maxilofaciais retidas por implantes necessitam de uma infraestrutura acrílica, na qual ficam contidos os sistemas de retenção; contudo, a união resina acrílica-silicone facial não é estável. Assim, este estudo teve como objetivo avaliar a influência da pigmentação com nanopartículas, técnica de união e envelhecimento acelerado sobre a resistência de união entre resina acrílica e silicone facial. Para tal, foram confeccionadas 960 amostras que consistiam em uma barra de resina acrílica de ativação química aderida ao silicone facial Silastic MDX 4-4210 incolor ou pigmentado com nanopartículas (tinta a óleo e/ou opacificador a base de sulfato de bário). A adesão entre os dois materiais foi feita pela simples deposição do silicone sobre a resina acrílica (N); por retenções mecânicas, representadas por ranhuras (R); aplicação do primer de uso médico (DC 1205 Prime - DC); primer para material reembasador (Sofreliner Primer MS- SF) ou adesivo de uso médico (Silatic Medical Adhesive Type A - A) isolados ou associados. Desta maneira, as amostras foram divididas em 4 grupos (n=240), de acordo com a nanopartícula adicionada ou não, sendo Grupo 1: Incolor; Grupo 2: Tinta a óleo; Grupo 3: Opacificador; e Grupo 4: Tinta a óleo e opacificador. Estes grupos foram divididos em 12 subgrupos (n=20), de acordo com o meio utilizado para unir a resina acrílica ao silicone, sendo: Subgrupo I: N; Subgrupo II: A; Subgrupo III: DC; Subgrupo IV: DC+A; Subgrupo V: SF; Subgrupo VI: SF+A; Subgrupo VII: R; Subgrupo VIII: R+A; Subgrupo IX: R+DC; Subgrupo X: R+DC+A; Subgrupo XI: R+SF; Subgrupo XII: R+SF+A. Metade das amostras de... / Abstract: Maxillofacial prosthesis retained by implants use an acrylic framework to fit the attachment systems. However, the bond between acrylic resin and facial silicone is instable. Therefore, this study investigated the influence of nanoparticles pigments, adhesive system and accelerated aging on the bond strength between the acrylic resin and facial silicone. A total of 960 specimens made of selfpolymerized acrylic resin bar adhered to Silastic MDX 4-4210 facial silicone either colorless or pigmented with nanoparticles (oil tint and/or barium sulfate opacifier) were fabricated. The union between the two materials was performed in different ways: no treatment on the acrylic bar (N), mechanical retentions represented by scratches (R), application of prime for medical use (DC 1205 Prime - DC), primer for soft liner material (Sofreliner Primer MS - SF), and adhesive for medical use (Silastic Medical Adhesive Type A - A) alone or in combinations. The specimens were divided into 4 groups (n=240) according to the nanoparticle presence: Group 1: colorless; Group 2: oil tint; Group 3: opacifier; and Group 4: oil tint and opacifier. These groups were divided into 12 subgroups (n=20) according to the surface treatment used to bond the facial silicone to the acrylic resin: Subgroup I: N; Subgroup II: A; Subgroup III: DC; Subgroup IV: DC+A; Subgroup V: SF; Subgroup VI: SF+A; Subgroup VII: R; Subgroup VIII: R+A; Subgroup IX: R+DC; Subgroup X: R+DC+A; Subgroup XI: R+SF; Subgroup XII: R+SF+A. Half of the specimens of each subgroup (n=10) were subjected to bond strength test at the baseline period in a universal testing machine at a crosshead speed of 10 mm/min until failure. The other specimens were exposed to the accelerated... / Doutor
82

Influência de agentes adesivos, irradiação por microondas e ciclagem termomecânica na resistência de união entre uma resina acrílica termoativada e um reembasador rígido /

Cavalcanti, Sâmia Carolina Mota. January 2012 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Banca: Renato Morales Jóias / Banca: Estevão Tomomitsu Kimpara / Resumo: Este trabalho tem como objetivo analisar a resistência de união entre uma resina acrílica ativada térmicamente (Vipiwave) e um reembasador rígido (Tokuyama rebase fast II) considerando-se fatores que possam influenciar nesta união, tais como: agentes adesivos, irradiação por micro-ondas e ciclagem termomecânica. Para a execução da pesquisa estabeleceram-se 16 grupos (n=10), para qual foram confeccionados corpos de prova em formato cilíndrico(13mmx23mm) em resina acrílica termoativada em forno de micro-ondas. Após a polimerização, estes receberam acabamento com lixa d'agua 400 e tiveram suas superfícies tratadas com Tokuyama Rebase II adhesive, adesivo Palabond ou o monômero da resina Vipiwave, e reembasados. Uma parte dos corpos de prova foi tratado em micro-ondas, sendo imersos em 200ml de água, e submetidos a um ciclo de 3 min a 650W. Outros grupos foram levadosa ciclagem termomecânica, onde o estresse mecânico foi de 10.000 ciclos a 3,8 Hz. Todos os corpos de prova foram submetidos ao teste de cisalhamento, com velocidade de 1mm/min e carga de 100Kgf em máquina de ensaios universal. Os corpos de prova passaram em avaliação por perfilometria. Após obtenção dos resultados, estes foram submetidos a análise estatística por Anova e Tukey (5%) para comparação entre os grupos. Verificou-se que tanto a irradiação em micro-ondas quanto a ciclagem termomecânica melhoraram significativamente a união nos grupos tratados com Palabond. Os grupos Tokuso e controle apresentaram melhor resistência adesiva após a ciclagem embora o grupo controle apresentasse os piores valores de resistência em todas as situações. Já os resultados de perfilometria mostraram que o adesivo Palabond criou uma superfície mais rugosa (Ra=185,4 m) quando comparado ao grupo Tokuso (Ra= 121,9 m). Concluiu-se desta... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to analyze the shear bond strength between a heat-activated acrylic resin (Vipiwave) and a soft liner (Tokuyama Rebase Fast II) considering factors that can influence bonding, such as adhesive agents, microwave irradiation and thermomechanical cycling. Sixteen groups (n=10) were stablished, and specimens of heat-activated acrylic resin were fabricated in a cylindrical shape (13mmx23mm) in microwave oven. After curing, they were finished with #400 sandpaper, the bonded surfaces were treated with Tokuyama Rebase II adhesive, Palabond or Vipiwave monomer, and were relined with Tokuyama Rebase Fast II. Half of specimens were microwave-cured (3 minutes at 650W). Remainder were heat-cured in water. Half of specimens were thermomechanical cycled (10,000 cycles at 3.8 Hz). Specimens were submitted shear bond strength test with crosshead speed of 1mm/min in a universal testing machine. Fractured specimens were evaluated in profilometry. Data (MPa) were submitted to 3-way ANOVA and Tukey test, both with =0.05 for comparison between groups. Microwave-cured and thermamechanical cycled Palabond treated groups showed higher bond strength. Untreated groups showed the lowest shear bond strengths and the groups treated with Tokuyama adhesive the highest bond strength values. Profilometry showed that Palabond created a rougher surface (Ra = 185.4 m) compared to Tokuso (Ra = 121.9 m). It was concluded that the surface treatment prior to relining, especially with Palabond produces satisfactory results, and microwave irradiation and thermomechanical cycling showed improvement of bond strength / Mestre
83

Influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão de resina específica para confecção de próteses oculares /

Andreotti, Agda Marobo. January 2014 (has links)
Orientador: Daniela Micheline dos Santos / Banca: Marcelo Coelho Goiato / Banca: Simone Cecílio Hallak Regalo / Resumo: Uma alternativa segura para reabilitar pacientes com anoftalmia é a utilização de próteses oculares. O conhecimento das propriedades físicas e mecânicas da resina acrílica utilizada na confecção destas próteses é de suma importância. Nanopartículas vêm sendo adicionadas à cadeia polimérica das resinas com o objetivo de melhorar essas propriedades. Assim, o propósito desse estudo foi avaliar a influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão da resina acrílica N1 específica para confecção da esclera artificial. Para isso, foram confeccionadas 300 amostras. As nanopartículas utilizadas foram Óxido de Zinco (ZnO), Dióxido de Titânio (TiO2) e Sulfato de Bário (BaSO4), nas concentrações de 1, 2 e 2,5%. As amostras foram distribuídas em 10 grupos (n=30) de acordo com o tipo e concentração de nanopartícula associada à resina acrílica N1: controle - sem nanopartícula (C), óxido de zinco 1% (ZnO 1%), óxido de zinco 2% (ZnO 2%), óxido de zinco 2,5% (ZnO 2,5%), dióxido de titânio 1% (TiO2 1%), dióxido de titânio 2% (TiO2 2%), dióxido de titânio 2,5% (TiO2 2,5%), sulfato de bário 1% (BaSO4 1%), sulfato de bário 2% (BaSO4 2%), sulfato de bário 2,5% (BaSO4 2,5%). Os ensaios de leitura de cor, microdureza e resistência à flexão foram realizados antes e após 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Os resultados demonstraram que, comparando-se as diferentes nanopartículas, os grupos com TiO2 apresentaram melhor estabilidade de cor, para todas as concentrações. Em relação ao teste de microdureza, com exceção dos grupos C e com adição de óxido zinco, os valores de microdureza aumentaram após envelhecimento, sendo que, nas concentrações de 1 e 2%, os grupos com... / Abstract: A safe, aesthetic and satisfactory alternative to rehab patients with anofthalmia is the use of ocular prosthesis. It is very important to know about the physical and mechanical properties of the acrylic resin used on this prosthesis production. Nanoparticles have been added to the acrylic resins polymeric chain in order to improve these properties. So, this study aims to assess the influence of nanoparticles addition on the color stability, microhardness, and flexural resistance of artificial sclera N1 acrylic resin. To this purpose, 300 samples were made. The nanoparticles used were Zinc Oxide (ZnO), Titanium Dioxide (TiO2) and Barium Sulfate (BaSO4), at the concentrations of 1, 2 and 2%. Samples were divided into 10 groups (n=30), according to the nanoparticle and concentration associated with the resin: control - without nanoparticle (C); zinc oxide 1% (ZnO 1%) ; zinc oxide 2% (ZnO 2%); zinc oxide 2,5% (ZnO 2,5%); titanium dioxide 1% (TiO2 1%); titanium dioxide 2% (TiO2 2%); titanium dioxide 2,5% (TiO2 2,5%); barium sulfate 1% (BaSO4 1%), barium sulfate 2% (BaSO4 2%); barium sulfate 2,5% (BaSO4 2,5%). The color stability, microhardness and flexural resistance tests were performed before and after 1008 hours of accelerated aging. Data were subjected to statistical analysis using nested ANOVA and Tukey test. The results showed that, comparing the different nanoparticles, the groups with TiO2 showed better color stability at all concentrations. Microhardness values increased after artificial aging, except for groups C and ZnO and groups with TiO2 at 1 and 2% showed the highest statistically significant values compared with the other nanoparticles. Regarding flexural strength, at initial period, there was statistically significant difference between control group and the other groups. By comparing the periods, the C group... / Mestre
84

Análise por computação gráfica da variação da posição relativa dos dentes artificiais antes e após o processamento de próteses totais superiores /

Shibayama, Ricardo. January 2002 (has links)
Orientador: Humberto Gennari Filho / Banca: Wirley Gonçalves Assunção / Banca: Marcelo Ferraz Mesquita / Resumo: Investigamos a alteração da posição dos dentes artificiais durante o processamento de próteses totais, utilizando as resinas de marcas comerciais QC 20 (Dentsply) e Onda Cryl (Clássico - específico de microondas), com inclusão em gesso e com muralha de silicone, polimerizadas tanto pelo método de banho por água quente, quanto pela polimerização por energia de microondas. Foram utilizadas 40 amostras, divididas em 4 grupos de 10, que receberam os seguintes tipos de processamento. a) grupo 1: incluídos em muflas metálicas com muralha de gesso pedra e polimerização convencional. b) grupo 2: incluídos em muflas de fibra de vidro com muralha de gesso pedra e polimerização com microondas. c) grupo 3: incluídos em muflas metálicas com muralha de silicone e polimerização convencional. d) grupo 4: incluídos em muflas de fibra de vidro com muralha de silicone e polimerização por energia de microondas. Para detecção dos deslocamentos dentais utilizamos um guia de resina acrílica com 5 pontos pré-determinados que proporcionou pontos de referência nas réplicas que permitiram mensurar tais deslocamentos através da utilização do programa de computador AutoCad. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram alteração da posição dos dentes após o processamento, b) a técnica com a menor movimentação dos dentes artificiais foi a técnica 4. / Abstract: This study investigated artificial tooth movement during the procedures of complete dentures base, using two different types of resins: QC 20 (Dentsply) and OndaCryl (Clássico specify for microwave energy), with gypsum stone mould and silicone mould. We used thermopolymerization in water bath and microwave polymerization. The forty samples utilized were divided into four groups of ten, which received the following type of inclusion and processing. Group 1: included in metallic flasks with gypsum stone mould and thermopolymerization in water bath and microwave polymerization; Group 2: included in resin-fiber glass flasks with gypsum stone mold and microwave polymerization; Group 3: included in metallic flasks with silicone mold and thermopolymerization in water bath; Group 4: included in resin-fiber glass flasks with silicone mould and microwave polymerization. For the measurement of artificial tooth movement, we used a resin acrylic guide with five daily determined points which provide references points. The AutoCad R 14 computer program was utilized for the measurements. All data were submitted to ANOVA and Tukey test. With the results we can conclude that: a) all the samples suffer artificial tooth movement, b) the smaller artificial tooth movement happen in group four. / Mestre
85

Influência do intemperismo natural ou induzido sobre a estabilidade cromática de próteses faciais, em função do material de confecção e da pigmentação /

Santos, Daniela Micheline dos. January 2008 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Alício Rosalino Garcia / Banca: Mário Alexandre Coelho Sinhoreti / Resumo: O maior problema enfrentado pelo protesista bucomaxilofacial é reproduzir a cor exata da pele do paciente, proporcionando uma estética agradável. Para alcançar este objetivo, o profissional deve ter materiais que possibilitem uma fácil caracterização, mantendo por um longo período de tempo a cor obtida. O propósito do presente estudo foi avaliar a estabilidade de cor de resinas acrílicas (Rapidaflex, Lentaflex e Resina Acrílica Termopolimerizável incolor e pigmentada) e de um silicone (Silastic MDX4-4210 incolor e com pigmentação) utilizados na confecção de próteses faciais, submetidos ao intemperismo natural ou artificial. Foram confeccionados 120 corpos-de-prova distribuídos em doze grupos. Metade dos corpos-de-prova foram submetidos ao envelhecimento natural por 180 dias, e a outra metade ao envelhecimento acelerado por 1008 horas. A alteração cromática dos corpos-de-prova foi verificada por meio da análise visual e da espectrofotometria de reflexão (Shimadzu, Kyoto, Japão). Os resultados foram submetidos à análise estatística pelos testes de Variância (ANOVA) de dois fatores e Tukey, com significância de 5%. Pode-se observar pela análise espectrofotométrica e visual que, independente do tipo de envelhecimento, ocorreu alteração de cor, estatisticamente significativa, entre alguns materiais. Os corpos-de-prova submetidos ao envelhecimento natural apresentaram maiores valores de alteração de cor do que aqueles submetidos ao envelhecimento acelerado. Todos os materiais sofreram alteração cromática pela influência da exposição ao meio ambiente ou pela ação do envelhecimento acelerado. / Abstract: The great problem that confronts the maxillofacial prosthodontist is reproduces the accurate color of the patient's skin, providing a satisfactory esthetic. Attempt to reach this purpose; the clinician should have materials to make an easy characterization, keeping the color by the time. The aim of this study was to evaluate the color stability of acrylic resins (Rapidaflex, Lentaflex and heat-cured colorless and pigmented acrylic resins) and a silicone (colorless and pigmented Silastic MDX4-4210) used to the confection of facial prostheses, submitted to natural or artificial weathering. 120 samples were made and distributed in twelve groups. 60 samples were submitted to the natural aging by 180 days, and the other half were submitted to the accelerated aging by 1008 hours. The chromatic differences were verified by means of the visual analysis and reflection spectrophotometer (Shimadzu, Kyoto, Japan). The results were analyzed by two-way analysis of variance (ANOVA) and Tukey tests (P<0,05). Color changes, between some materials, were observed by spectrophotometer and visual analysis, independently of the type of aging; it was statistically significant. The samples submitted to the natural aging showed higher values than the samples submitted to the accelerated aging. All materials suffered chromatic differences because to the environment exposure or the accelerated aging. / Mestre
86

Protese ocular individualizada em resina acrílica com esfera oca /

Oliveira, Simone Helena Gonçalves de. January 1995 (has links)
Orientador: Rolf Rode / Banca: Maria Cecília Montagna Rosé / Banca: Horácio Faig Leite / Resumo: A técnica proposta visa conseguir uma diminuição de peso das próteses oculares individualizadas amplas de resina acrílica, com passos laboratoriais simplificados. Para isso utilizaram-se esferas ocas pré fabricadas de material plástico, que são incluídas dentro da esclera. Compararam-se os pesos médios de escleras maciças convencionais (5,30g) com os de escleras com esferas ocas pré-fabricadas de material plástico (3,91g), respectivamente. A redução de peso foi significante com intervalo de confiança de 95% pelo teste "t " de "Student". Foi também executada a técnica, a título de ilustração, em pacientes do Ambulatório da Disciplina de Prótese Buco-Maxilo-Facial da Faculdade de Odontologia do Câmpus de São José dos Campos-Unesp, tendo cada paciente recebido uma prótese maciça e uma prótese com esfera oca pré-fabricada de material plástico. Concluiu-se que as próteses e as escleras que possuem no seu interior a esfera oca pré-fabricada de material plástico são mais leves que as escleras maciças e que a técnica é viável para cavidades anoftálmicas amplas e é praticada em poucas sessões / Abstract: The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the "Student" "t" test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions / Mestre
87

Avaliação do uso de uma estrutura de nylon modificada como reforço de prótese totalmente acrílica implantossuportada /

Gonçalves, Fernanda de Cássia Papaiz. January 2015 (has links)
Orientador: Tarcísio José de Arruda Paes Júnior / Co-orientador: Vanessa Cruz Macedo / Banca: Alexandre Luiz Souto Borges / Banca: Estevão Tomomitsu Kimpara / Banca: Eduardo Miyashita / Banca: Mayra Cardoso / Resumo: O estudo avalou o comportamento de uma estrutura de nylon experimental com o propósito de ganho na resistência mecânica do material e ainda, na melhor distribuição de forças em toda extensão da prótese ao longo eixo dos implantes diminuindo o risco de fraturas e falhas neste sistema e, consequentemente maior longevidade. Para isso considerou-se próteses do tipo protocolo sem barra metálica, com e sem incorporação de reforço (nylon), variando a extensão da região do cantilever até primeiro molar/ segundo pré-molar (n=6). Os corpos de prova foram submetidos à análise de deformação por extensometria (extensometria s) e carga de 30 kg, e ao teste de carga máxima à fratura na EMIC (1000 kgf, 2 mm/min). Pode-se concluir que a incorporação da estrutura de reforço aumentou os valores de carga máxima independentemente da extensão do cantilever, além de apresentar menores valores de micro deformação ao redor de todos os implantes. As extensões de cantilever em pré-molar (5mm) além de apresentarem os menores valores de micro deformação quando comparadas a extensão em molar (15mm) também mostraram os maiores valores de carga máxima à fratura. / Abstract: The study evaluated the behavior of a new compound of experimental nylon fiber, with the purpose of increasing the mechanical strength of the material and improving the strain distribution to the fullest extent of the prosthesis to the long axis of the implants reducing the risk of fractures and faults in the system and therefore increasing longevity. For this considered protocol type prostheses without metal bar, with and without incorporating reinforcement (nylon), varying the extent of the region of the cantilever to the first molar / second premolar (n = 6). The samples were subjected to analysis by extensometer strain (extensometria ) and load of 30 kg, and the maximum load test to fracture the EMIC (1000 kgf, 2 mm / min). It can be concluded that the incorporation of reinforcing mesh increased maximum load values regardless of the extent of the cantilever, and exhibit lower values microstrain around all implants. The cantilever extensions in premolar (5 mm) in addition of having the smallest microstrain values compared the extent to molar (15mm) also showed the highest maximum load values to fracture / Doutor
88

Efeito da irradiação por microondas sobre a resistência à flexão e dureza de resinas acrílicas para reembasamento imediato /

Ribeiro, Daniela Garcia. January 2004 (has links)
Orientador: Ana Cláudia Pavarina / Banca: Eunice Teresinha Giampaolo / Banca: Ricardo Faria Ribeiro / Resumo: O uso do microondas tem sido indicado como um método efetivo na desinfecção de resinas acrílicas. Entretanto, há pouca informação sobre o efeito da irradiação do microondas nas propriedades mecânicas desses materiais. Considerando esses aspectos, o objetivo deste estudo foi avaliar o efeito da irradiação por microondas sobre as propriedades mecânicas de resistência à flexão e dureza de resinas acrílicas. Os corpos-de-prova para a realização dos testes mecânicos foram confeccionados com os seguintes materiais: Kooliner (K), Tokuso Rebase Fast (TR), Ufi Gel Hard C (UGH) e New Truliner (NT), todas resinas indicadas para reembasamento imediato, e Lucitone 550 (L), que é uma resina para base de prótese. Para cada material foram confeccionados 48 corpos-de-prova que foram divididos igualmente em seis grupos. As resinas autopolimerizáveis (K, TR, UGH e NT) foram submetidas à irradiação logo após a confecção, enquanto que os corpos-de-prova da resina termopolimerizável (L) permaneciam 50 l 2 horas em água a 37ºC l 1ºC antes da irradiação. Para o procedimento de irradiação, cada corpo-de-prova foi individualmente imerso em 200 mL de água destilada e submetido a dois ciclos de irradiação pelas microondas, para simular o envio da prótese ao laboratório e o retorno dela ao consultório odontológico. Cada corpo-de-prova foi irradiado a uma potência constante de 650 W, variando-se o tempo de exposição: 1 minuto (T1), 2 minutos (T2), 3 minutos (T3), 4 minutos (T4) ou 5 minutos (T5). O grupo controle (T0) foi submetido aos testes mecânicos sem ser irradiado pelas microondas. Os ensaios de resistência à flexão para todos os corpos-de-prova foram realizados em máquina MTS-810 Material Test System sob velocidade de 5 mm/minuto, utilizando o teste em três pontos a uma distância de 50 mm entre os apoios. Em seguida, um dos fragmentos do ...(Resumo completo, clicar acesso eletônico abaixo) / Abstract: Microwave irradiation was previous suggested as an effective method for the disinfection of acrylic resins. However, little information is available concerning the effect of microwave irradiation on the mechanical properties of acrylic resins. The purpose of this study was to evaluate the effect of two cycles of a microwave disinfection procedure on the flexural strength and Vickers hardness of acrylic resins. Four autopolymerized resins (Kooliner- K, Tokuso Rebase Fast- TR, Ufi Gel Hard- UGH and New Truliner- NT) and one heat-cured resin (Lucitone 550- L) were used for preparing specimens. For each material, 48 specimens were made and equally divided into six groups. The relined specimens were submitted to disinfection procedures after polymerization and the denture base polymer specimens were stored in water for 50 l 2 hours at 37ºC l 1ºC prior to disinfection. The specimens were individually immersed in 200 mL of destilated water and microwaved twice, simulating when dentures come from the patient and before being returned to the patient. Each cycle of microwave disinfection was performed at 650 W for one of the following irradiation times: 1 minute (T1), 2 minutes (T2), 3 minutes (T3), 4 minutes (T4) or 5 minutes (T5). Control group (T0) specimens were subjected to mechanical tests without being disinfected. The flexural strength values of the materials were determined using a testing machine MTS-810 at a crosshead speed of 5 mm/minute using a three-point bending fixture with a span of 50 mm. Thereafter, one fragment of specimen was submitted to Vickers microhardness test. The values were determined by using a 25 gf load, after 30 seconds contact. Twelve hardness measurements were taken on each specimen and the average was then calculated. The flexural and hardness values were submitted to ANOVA and ...(Complete abstract, click electronic access below) / Mestre
89

Avaliação da adesão de Staphylococcus spp. em resina acrílica específica para prótese ocular e alteração de cor de botões de íris artificiais, variando a cor e as técnicas de obtenção, ambos após desinfecção química /

Moreno, Amália. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Co-orientador: Daniela Micheline dos Santos / Banca: Eduardo Piza Pellizzer / Banca: Humberto Gennari Filho / Banca: Simone Cecílio Hallak Regalo / Banca: Célia Regina Moreira Lanza / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. Assim, os materiais utilizados na confecção de prótese ocular devem possuir propriedades específicas para sua indicação e durabilidade principalmente aos procedimentos de desinfecção pelo paciente. Desse modo, este estudo teve como objetivo verificar a efetividade de diferentes soluções desinfetantes na remoção de biofilme de duas espécies de Staphylococcus spp., desenvolvidas na superfície de resina acrílica específica para prótese ocular e avaliar a alteração de cor de botões de íris artificiais confeccionadas por diferentes técnicas antes e após a polimerização e quando influenciadas pela desinfecção química. Para o teste de microbiologia, 396 amostras em resina acrílica para prótese ocular N1 foram confeccionadas (1,0 cm em diâmetro e 0,3 cm em espessura), sendo metade dessas amostras para formação de biofilme de S. epidermidis e a outra metade para formação de biofilme de S. aureus, ambos na superfície da amostra. Para cada cepa bacterina, 66 amostras foram submetidas a formação de biofilme em sua superfície durante três diferentes tempos: inicial (24h), intermediário (48h) e maduro (72h). Em seguida as amostras foram distribuídas aleatoriamente (unidade amostral n=6) para um dos tratamentos desinfetantes: água destilada durante 10, 15, 30 min e 6 h (controle-CTL); sabão neutro (NES) durante 30 min; Opti-Free durante 30 min e 6 h; Efferdent (EFF) durante 15 min; e gluconato de clorexidina (0,5%; 2% e 4%) (CHX) durante 10 min. Após o tratamento desinfetante, as amostras acrílicas foram imediatamente agitadas para desprendimento do biofilme. A contagem de colônias foi verificada por análise do número de UFC/mL. Para a análise de alteração de cor 300 amostras simulando próteses oculares foram confeccionadas, sendo metade... / Abstract: Considering that ocular prostheses restore esthetics and patient's self-esteem, the materials used for prosthesis fabrication should present appropriate properties regarding indication and reliability after the disinfection procedures. So, the aim of this study was to assess the effectiveness of different disinfectant solutions against two species of Staphylococcus spp. cultured on ocular prosthesis acrylic resin. In addition, the chromatic change of artificial iris buttons fabricated with different techniques was also evaluated before and after polymerization and disinfection. For the microbiology tests 396 acrylic specimens were fabricated (1.0 cm in diameter and 0.3 cm in thickness). Half of the samples were made for biofilm formation of S. epidermidis and half were made for biofilm formation of S. aureus, both on the sample surface. For each strain, 66 samples were underwent to biofilm formation on the liner surface for three different points: initial (24h), intermediate (48h) and mature (72h). Afterwards the specimens were randomly assigned (unit sample n = 6) to one of disinfectant treatments: distilled water for 10, 15, 30 min and 6 h (control-CTL); treated with neutral soap (NES) for 30 min; treated with Opti-Free (OPT) for 30 min and 6 h; treated with Efferdent (EFF) for 15 min; and treated with (0.5%, 2% and 4%) chlorhexidine gluconate (CHX) for 10 min. After the treatments, the specimens were vortexed to disrupt the biofilm, and residual cells were counted (cell/mL). For the color meansurations a total of 300 samples simulating ocular prosthesis were fabricated. Half of the samples were made with blue artificial irises, and half were made with brown artificial irises. For each color, 50 samples were fabricated according to one of the following techniques: PE - conventional technique, CA - prefabricated... / Doutor
90

Resistencia ao impacto e morfologia de fratura de resinas acrilicas processadas por energia de microondas e banho de agua quente / Impact strenght and fracture morphology of heat and microwaves polymerized acrylic resins

Costa, Marcelo de Almeida 30 August 2005 (has links)
Orientador: Renata Cunha Matheus Rodrigues Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T11:29:35Z (GMT). No. of bitstreams: 1 Costa_MarcelodeAlmeida_M.pdf: 3239895 bytes, checksum: cf5932b7fd5f5024e8d16d48a3f2b663 (MD5) Previous issue date: 2005 / Resumo: Foi objetivo deste trabalho avaliar a resistência ao impacto e morfologia de fratura de resinas acrílicas processadas por microondas e banho de água quente. Foram confeccionados 20 corpos-de-prova por grupo medindo 65x10x2,5mm para as resinas: Lucitone 550 (74oC/9 horas); Onda Cryl (3 minutos/360W, 4 minutos/pausa, 3 minutos/810W); Acron MC (3 minutos/500W) e Vipi Wave (20 minutos/180W, 5 minutos/540W). A resistência ao impacto foi avaliada em máquina Otto Wolpert Werke pelo método Charpy, com energia de carga de 40 Kp.cm (3,9466J), e as fraturas classificadas em frágeis ou intermediárias. A fractografia foi realizada por análise dos ângulos de propagação das fendas, e a caracterização morfológica microestrutural por observação em microscopia eletrônica de varredura (MEV). Os resultados de resistência ao impacto foram submetidos ao teste de Tukey e para comparação dos ângulos A e B dos fragmentos fraturados, foi aplicado o teste de Kruskal-Wallis e Coeficiente de Pearson. Foram observadas diferenças (p<0,01) para a resistência ao impacto, sendo que a resina Vipi Wave apresentou o menor valor. A maioria das fraturas foi classificada como frágil (Lucitone 550=56%, Onda Cryl=75%, Acron MC=90%, Vipi Wave=65%). A análise angular das fraturas frágeis não evidenciou diferenças, entretanto para fraturas intermediárias a resina Onda Cryl diferiu (p<0,01) das demais. A MEV evidenciou que fraturas frágeis apresentam planos cristalográficos definidos e organizados, enquanto que as intermediárias apresentam grau de desorganização. Conclui-se que resinas de microondas apresentam resistência ao impacto semelhante às de banho de água quente, e independente do processamento, as resinas apresentaram maior número de fraturas frágeis / Abstract: The aim of this study was to evaluate to the impact to resistance and morphology of processed acrylic resin breaking for microwaves and hot water bath. 65x10x2,5mm for resins had been confectioned 20 samples measuring: Lucitone 550 (74ºC/9 hours); Cryl wave (3 minutes/360W, 4 minutes/brake, 3 minutes/810W); Acron MC (3 minutes/500W) and Vipi Wave (20 minutes/180W, 5 minutes/540W). The impact to resistance was evaluated in machine Otto Wolpert Werke for the Charpy method, with load of 40 Kp.cm (3,9466J), and breakings classified in the fragile or intermediate. The fractography was carried through by analysis of the angles of propagation of the cracks, and the microstructural morphologic characterization for comment in electronic microscopy of sweepings (MEV). The results of impact to resistance had been submitted to the test of Tukey and for comparison of the angles the test of Kruskal-Wallis and coefficient of Pearson was applied. Differences (p<0,01) had been observed for the impact to, being that the resin Vipi Wave presented the lesser value. The majority of the breakings were classified as fragile (Lucitone 550=56%, Onda Cryl=75%, Acron MC=90%, Vipi Wave=65%). The angular analysis of the fragile breakings did not evidence differences, however for intermediate breakings the resin Onda Cryl differed (p<0,05) of excessively. The MEV evidenced that fragile breakings present definite and organized cristalgraphic plans, while that the intermediate present disorganization degree. One concludes that resins of microwaves present resistance to the similar impact to the ones of hot water bath, and independent of the processing, the resins had presented greater number of fragile breakings / Mestrado / Protese Dental / Mestre em Clínica Odontológica

Page generated in 0.0878 seconds