• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 210
  • 210
  • 112
  • 105
  • 89
  • 68
  • 45
  • 33
  • 28
  • 25
  • 24
  • 23
  • 23
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Efetividade de vernizes fotopolimerizáveis experimentais na redução da hidrofobicidade e adesão de Candida albicans em uma resina para base de prótese

Lazarin, Andréa Azevedo [UNESP] 29 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-29Bitstream added on 2014-06-13T20:26:08Z : No. of bitstreams: 1 lazarin_aa_dr_arafo.pdf: 2142552 bytes, checksum: 63a785fe41ed3de17382a8e94e97b844 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Foi proposto avaliar diferentes vernizes experimentais, que apresentam em sua formulação monômeros hidrofílicos ou zwiteriônicos, como método para modificar a superfície de resina acrílica para base de prótese, com o objetivo de prevenir a adesão de C. albicans. Foram confeccionados corpos-de-prova com características superficiais que simulavam a parte polida das próteses (superfície lisa) e com características superficiais que simulavam a parte interna das próteses (superfície rugosa) utilizando-se uma resina para base de prótese específica para micro-ondas (Vipi Wave). Matrizes metálicas com 10 cavidades (13,8 mm de diâmetro e 2 mm de altura) foram incluídas em mufla, entre 2 placas de vidro, para simular a superfície lisa, ou em contato com gesso para obter amostras que simulassem a superfície rugosa da prótese. Todos os corpos-de-prova foram submetidos à mensuração da rugosidade utilizando-se um rugosímetro (Mitutoyo SJ 400) com cutoff de 2,5 mm. A rugosidade superficial foi determinada (Ra-µm) pela média de três mensurações realizadas em cada amostra. Após a leitura da rugosidade, os corpos-de-prova foram divididos em grupo controle (n=72; 36 lisos e 36 rugosos), não recebendo nenhum tratamento superficial, e 12 grupos experimentais (n=72; 36 lisos e 36 rugosos) que receberam uma camada do verniz experimental sendo polimerizado em forno EDG. Os vernizes experimentais apresentaram em sua composição o monômero metil metacrilato (MMA), dois agentes de ligação cruzada (TEGDMA e Bis-GMA) e o foto iniciador MBP (4- metil benzofenona). Além desses componentes, os vernizes identificados pelos códigos P, E e T apresentaram monômeros hidrofílicos em 3 concentrações (25, 30 e 35%). O verniz identificado pelo código M apresentou um monômero zwiteriônico (MZ), nas mesmas... / The aim of the present study was to evaluate the use of different experimental varnishes containing zwitterion or hydrophilic monomers as a manner to modify the surface characteristics of a denture base resin and prevent the adhesion of C. albicans. For such purpose, specimens with surface characteristics that simulated the polished side of the dentures and the inner side of the dentures were fabricated using a microwave-polymerized denture base acrylic resin (Vipi Wave). Hollow metallic matrices with 10 cavities (13.8 mm diameter x 2 mm high) were flasked either between two glass plates, in order to produce specimens with smooth surfaces that simulated the polished side of the dentures, or in direct contact with the stone, in order to obtain specimens with rough surfaces that simulated the inner side of the dentures. All specimens were subjected to surface roughness readings in a roughness meter (Mitutoyo SJ 400) with cutoff length of 2.5 mm. Surface roughness (Ra, µm) was determined as the average of three random measurements made on each specimen. After the roughness readings, the specimens were randomly assigned to one control group (n=72; 36 smooth and 36 rough specimens), in which the specimens received no surface treatment, and 12 experimental groups (n=72; 36 smooth and 36 rough specimens) in which the specimens were coated with one of the experimental varnishes followed by polymerization in an EDG oven. The 12 experimental varnishes presented in their composition the monomer methyl methacrylate (MMA), two crosslinking agents (TEGDMA and Bis-GMA) and a photoinitiator agent (4-methyl benzophenone . MPB). In addition to these components, the experimental varnishes labeled as P, E and T presented hydrophilic monomers at three concentrations (25, 30 and 35%). The experimental varnish labeled as M presented a zwitterion... (Complete abstract click electronic access below)
72

Análise in vitro da proliferação celular e produção de mediadores inflamatórios por células da conjuntiva estimuladas por materiais utilizados na confecção de próteses oculares

Silva, Emily Vivianne Freitas da [UNESP] 07 April 2015 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:25:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-04-07. Added 1 bitstream(s) on 2015-09-17T15:46:23Z : No. of bitstreams: 1 000847893.pdf: 1252256 bytes, checksum: 1fd716895e2784e4359da8659fd760e0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A prótese ocular é utilizada para a reabilitação estética e funcional da ausência ocular. O conhecimento da sua biocompatibilidade é importante para a utilização sem reações danosas aos usuários. O objetivo neste estudo foi avaliar a citotoxicidade de materiais utilizados na confecção de próteses oculares, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por células da conjuntiva humana. Inicialmente, foi analisada a influência de diferentes períodos de formação e de exposição dos extratos de resina acrílica branca (N1), termopolimerizada em água aquecida, sobre culturas de células da conjuntiva. Foram confeccionados 24 corpos de prova em resina, sendo 12 para cada período de exposição de células da conjuntiva aos extratos da resina testada (24 e 72 horas). Após a formação dos extratos por 24, 48 e 72 horas de imersão em meio de cultura e, 24 horas em água seguido de 24 horas de imersão em meio, os ensaios propostos foram realizados (n=3). Em seguida, foi avaliado o efeito citotóxico de diferentes métodos de polimerização de resina acrílica N1 em células da conjuntiva. Foram confeccionados 9 corpos de prova em resina (n=3), termopolimerizados em água aquecida, por energia de microondas ou ativados quimicamente, utilizados para a formação dos extratos dessas resinas. Os extratos foram obtidos após 72 horas de imersão dos corpos de prova em meio de cultura e, então, expostos às células da conjuntiva por 72 horas para a realização dos ensaios propostos. Adicionalmente, foi analisada a influência da presença do pigmento acrílico na confecção da prótese de resina acrílica N1, termopolimerizada em água aquecida... / Ocular prosthesis is a treatment option for esthetical and functional rehabilitation of ocular absence. The knowledge of ocular prosthesis material's biocompatibility is important to ensure a safe use in patients. The aim of this study was to evaluate the cytotoxic effect of ocular prosthesis materials, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by a human conjunctival cell line. Initially, the influence of different preparation and exposition periods of eluates from heat-polymerized ocular prosthesis N1 color acrylic resin in human conjunctival cell line was evaluated. A total of 24 acrylic resin samples were manufactured and divided into 2 groups, according to the eluate exposition period to conjunctival cell line (24 and 72 hours). Eluates corresponding to 24, 48 and 72 hours of resin sample immersion in medium and, 24 hours of resin sample immersion in water followed by 24 hours of immersion in medium, were prepared (n=3) for the proposed tests. Then, the cytotoxic effect of different polymerization methods of ocular prosthesis N1 color acrylic resin was analyzed. A total of 9 acrylic resin samples were manufactured (n=3), according to the polymerization method: heat-polymerization in water bath, polymerization by microwave energy and auto-polymerization. Eluates corresponding to 72 hours of resin sample immersion in medium were prepared for proposed tests and exposed to conjunctival cell line for 72 hours. Additionally, the influence of pigment incorporation on the cytotoxicity of heat-polymerized ocular prosthesis N1 color acrylic resin was evaluated...
73

Avaliação clínica e microbiológica da secreção conjuntival em usúarios de prótese ocular em resina acrílica

Neves, Ana Christina Claro [UNESP] 14 June 2000 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-06-14. Added 1 bitstream(s) on 2018-07-27T18:29:53Z : No. of bitstreams: 1 000127134.pdf: 1653433 bytes, checksum: a86ba2adfc63a2d23fea7089b1555de7 (MD5) / Este trabalho objetivou avaliar a microbiota bacteriana e fúngica das cavidades anoftálmicas, próteses oculares e olhos contralaterais de 43 usuários de prótese ocular em resina acrílica, unilateral, e relacionar a quantidade de secreção conjuntival presente nessas cavidades com a microbiota conjuntival, frequência de limpeza, tempo de uso e tempo decorrido desde o último polimento da prótese. Todos os pacientes apresentavam secreção conjuntival e microbiota Gram positiva nas cavidades anoftálmicas, Os microrganismos mais frequentemente isolados das 43 cavidades anoftálmicas, por ordem decrescente de freqüência, foram: Staphyfococcus coagulase negativos, Staphylococcus aureus, Candída albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Microbiota Gram negativa foi isolada de oito cavidades e fúngica, de três. O estudo estatístico dos dados evidenciou relação não significativa entre a quantidade de secreção conjuntival e a presença de microbiota Gram negativa• nas cavidades; e entre a quantidade de secreção conjuntival e a frequência de limpeza da prótese ocular. Correlação, estatisticamente significativa, foi constatada entre a quantidade de secreção conjuntiva! e o tempo de uso e o tempo decorrido desde o último polimento da prótese / The purpose of this work was to evaluate the bacterial and fungic microbiota of the anophthalmic sockets, ocular prosthesis and fellow eyes of forty three acrylic resin prosthesís carrying patients, and thereby relate the amount of conjunctival discharge to the presence of organisms, frequency of prosthesis cleaning, time of use and elapsed time since the last prosthesis polishing. All patients showed conjunctival discharge and Gram positive organisms in the anophthalmic sockets. The predominant organisms in the anophthalmic sockets were Staphylococcus coagulase negative, Staphylococcus aureus, Candida albicans, Proteus mirabilis, Citrobacter koseriana, Streptococcus pyogenes, Pseudomonas aeruginosa, Enterobacter sakazakii e Enterobacter aerogenes. Gram negative bacteria were found in eight anophthalmic sockets and fungi in three. No relation was found between the amount of the conjunctival discharge and the presence of Gram negative bacteria in the anophthalmic socket, nor with the frequency of prosthesis cleaning. However, there was a significant relation between the amount of conjunctival discharge and time of prosthesis use, as well as time elapsed since the last prosthesis polishing
74

Avaliação in vitro da biocompatibilidade de resinas acrílicas para base de próteses e materiais reembasadores resilientes /

Chaves, Carolina de Andrade Lima. January 2013 (has links)
Orientador: Ana Lúcia Machado / Co-orientador: Carlos Alberto de Souza Costa / Banca: Ana Carolina Pero Vizoto / Banca: João Neudenir Arioli Filho / Banca: Cláudia Helena Lovato da Silva / Banca: Renata Cunha Matheus Rodrigues Garcia / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de 3 resinas acrílicas (RA) para bases de prótese sendo duas polimerizadas por energia de microondas (Vipi Wave-VW e Nature Cryl-NC) e uma fotoativada (Eclipse-E); e a biocompatibilidade de materiais reembasadores resilientes (MRR), sendo 2 à base de silicone (Ufi Gel P e Sofreliner S), 2 à base de resina acrílica (Durabase Soft e Trusoft) e 2 condicionadores de tecidos (Softone e Coe Comfort) por meio de análises do metabolismo celular, da morfologia celular, do padrão de morte celular, da proliferação celular e da expressão do fator de crescimento TGFß 1, da integrina α5ß1 e de citocinas. A análise das RA foi realizada com células L929; para os MRR, as análises foram realizadas utilizando-se células L929, e/ou HaCaT e/ou RAW 264,7. Os resultados obtidos foram submetidos à análise estatística, realizada ao nível de significância de 5%. Todos os materiais quando testados com eluatos não apresentaram efeitos citotóxicos, e quando testados em contato direto (MTT e azul de alamar) alteraram significativamente a viabilidade celular, tendo sido os menores valores observados para o material NC quando comparado ao E. Para os materiais reembasadores o T, S e C. Maior taxa de necrose e apoptose foram observadas para os eluatos de todos os materiais quando avaliados no período de 24 horas; além disso, foi demonstrado que os materiais avaliados podem desencadear a expressão do TGFß 1, da integrina α5ß1 e de proteínas inflamatórias (fator de necrose tumoral - TNF-α, da citocina IL-1ß e de 5 quimiocinas: CCL2, CCL3, CCL5, CXCL2 e CXCL4). Sendo assim, de acordo com as limitações do presente estudo, pode-se concluir que a resina Nature Cryl resultou em menor viabilidade celular que a resina Eclipse e que os materiais Ufi Gel P e Sofreliner S apresentaram, em geral, melhor bicompatibilidade dentre os materiais reembasadores resilientes avaliados. / Abstract: The aim of this study was to evaluate the cytotoxicity of 3 denture base acrylic resins with different polymerization methods (Eclipse, Vipi Wave and Nature Cryl) and the biocompatibility of soft lining materials, 2 silicone-based (Ufi Gel P and Sofreliner S), 2 acrylic-based (Durabase Soft and Trusoft) and 2 tissue conditioners (Softone and Coe Comfort), by analysing cell metabolism, cell morphology, pattern of cell death, cell proliferation and expression of growth factor TGFß 1, integrin α5ß1 and cytokines. For the acrylic resins, analyses were made with L929 cells, while for the resilient lining materials, analyzes were performed using L929, and/or HaCaT and/or RAW 264.7 cells. Results were statistically analyzed, at a significance level of 5%. The 24 and 48-h eluates from all materials were not cytotoxic to the cells. For the direct contact tests (MTT and Alamar Blue), a significant effect on cell viability was found, with the lowest values observed for materials NC when compared with E and between the reliners Trusoft, Softone and Coe Comfort. For all materials, increased rate of necrosis and apoptosis were observed for the 24 hs eluates. It was also demonstrated that all materials tested can trigger the expression of TGFß 1, α5ß1 integrin and inflammatory proteins (tumor necrosis factor -TNF-α, cytokine IL-1ß and 5 chemokines- CCL2, CCL3, CCL5, CXCL2 and CXCL4). Thus, within the limitations of this study, it can be concluded that the denture base acrylic resin Nature Cryl resulted in lower cell viability compared to the Eclipse resin and that the materials Ufi Gel P and Sofreliner S showed better biocompatibility among the soft liner materials evaluated. / Doutor
75

Efetividade de vernizes fotopolimerizáveis experimentais na adesão e formação de biofilme multiespécies e sua associação com a escovação na remoção e recolonização do biofilme de uma resina acrílica para base de prótese /

Izumida, Fernanda Emiko. January 2013 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Paula Dias Ribeiro / Banca: Dalva Cruz Laganá / Banca: Janaína Habib Jorge / Banca: João Neudenir Arioli Filho / Resumo: Este estudo avaliou dois vernizes experimentais (M e P) em três diferentes concentrações (25, 30 e 35%) na prevenção da adesão e formação de biofilme multiespécies (Candida albicans, Candida glabrata e Streptococcus mutans) e sua associação com a escovação na remoção do biofilme e sua recolonização. Corpos-de-prova lisos e rugosos de uma resina acrílica foram confeccionados e divididos em grupos experimentais, de acordo com o verniz e concentração, além de grupos controle (sem verniz). Metade das amostras foi exposta em saliva (30 minutos). Posteriormente, realizou-se a adesão (90 minutos) ou a formação do biofilme multiespécies (48 horas). Para a avaliação da capacidade de remoção do biofilme aderido, corpos-de-prova contaminados foram escovados (30 segundos) e para a recolonização, além da escovação, as amostras foram incubadas por período adicional de 48 horas. Os micro-organismos remanescentes foram mensurados pelos ensaios de XTT e UFC. Para os testes de adesão e formação do biofilme, os grupos experimentais apresentaram, em geral, menor absorbância comparados com o controle, porém esta diferença não foi significante para a contagem de colônias, exceto para o S. mutans na formação do biofilme. A rugosidade, em geral, não promoveu alteração em qualquer dos testes realizados. A saliva não promoveu alterações na adesão dos micro-organismos, mas alterou a quantidade de biofilme formado. Houve remoção efetiva do biofilme com a escovação e com a recolonização. Conclui-se que os vernizes fotopolimerizáveis experimentais reduziram discretamente a adesão e formação do biofilme. Além disso, a escovação foi efetiva na remoção e recolonização do biofilme multiespécies. / Abstract: This study evaluated the ability of two experimental coatings (M and P) at 25, 30 and 35% concentrations to modify the surface characteristics of a denture base resin and prevent the adhesion and biofilm formation of multi-species, as well as the effectiveness of brushing on biofilm removal and their recolonization. Specimens with smooth and rough surfaces were prepared and divided into experimental groups, according to the coating and concentration, and controls group (without coating). A half of specimens were exposed to saliva (30 minutes). The microorganisms adhesion (Candida albicans, Candida glabrata and Streptococcus mutans) was performed for 90 minutes and the biofilm formation was performed for 48 hours. For effectiveness of toothbrushing in biofilm elimination test, contaminated specimens with biofilm were exposed to toothbrushing in a brushing machine (30 seconds) and for recolonization, after brushing, the specimens were incubated again for 48 hours. Microorganisms quantification was measured by XTT and UFC tests. The adhesion and biofilm development showed that the experimental groups were, in general, lower absorbance compared with the control, but this difference was not significant for colony counting, except for S. mutans in biofilm formation. The roughness, in general, did not cause any change in all tests performed. Saliva did not change the adhesion of microorganisms, but reduce the biofilm formation. There was effective biofilm removal with brushing and recolonization tests. It was concluded that the experimental photopolymerised coatings slightly reduced adhesion and biofilm formation. Furthermore, toothbrushing was effective in multi-species biofilm removal and their recolonization. / Doutor
76

Síntese, caracterização e atividade antimicrobiana de nanofibras de polietilmetacrilato / nistatina produzidas por eletrofiação /

Santos, Jessica Dias. January 2017 (has links)
Orientador: Alexandre Luiz Souto Borges / Coorientadora: Cristiane Campos Costa Quishida / Banca: Cesar Rogério Pucci / Banca: Bruno Vinícius Manzolli Rodrigues / Resumo: O objetivo desse estudo foi sintetizar mantas não tecidas de nanofibras (NFs) de Polietilmetacrilato (PEMA) com adição de nistatina (NYS) e avaliar a atividade antimicrobiana nas resinas reembasadoras rígidas e macias. Realizou- se o teste microbiológico da CIM de NYS para a inativação da C. albicans. NFs foram sintetizadas pela técnica da eletrofiação, utilizando-se solução de PEMA puro e NYS e PEMA. Para a síntese das NFs de PEMA, foi produzida uma solução de PEMA dissolvido em Dimetilformamida (DMF) e 1,1,2,2 Tetracloroetano (TCE), logo após foram adicionadas duas concentrações de NYS (10 e 20 mg/ml) obtidas do teste CIM. As amostras foram analisadas em Microscopia Eletrônica de Varredura (MEV), Análise de molhabilidade, Análise de Difratometria de Raios-X (DRX) e Espectroscopia de Infravermelho por Transformada de Fourier (FTIR). Após a análise em MEV foi realizada a média dos diâmetros das fibras com Software ImageJ. As atividades antimicrobianas foram avaliadas por meio do teste de difusão em ágar. As NFs de PEMA apresentaram diâmetro menor, o padrão NF/PEMA apresentou 0,42µm enquanto que a NF/20 1,14 µm e a NF/10 foi de 0,87 µm. As fibras foram consideradas hidrofóbicas por meio da análise de molhabilidade. O DRX e o FTIR comprovaram a presença de PEMA e sugeriram a presença de NYS. O teste de difusão em ágar demonstrou que as fibras não conseguiram inibir a proliferação de C. albicans / Abstract: The objective of the study was to synthesize nanofibers (NFs) of Polyethylmethacrylate (PEMA) with addition of Nystatin (NYS) and to evaluate an antimicrobial activity in rigid and soft resins. Microbiological testing of NYS MIC for inactivation of C. albicans was performed. NFs were synthesized using the electrochemical technique using pure PEMA and NYS and PEMA solutions. For a synthesis of PEMA NFs, a solution of PEMA dissolved in Dimethylformamide (DMF) and 1,1,2,2 Tetrachloroethane (TCE) was produced, following doses of NYS concentrations (10 and 20 mg / ml) obtained from the CIM. As samples were analyzed in Scanning Electron Microscopy (SEM), Goniometer, X-ray Diffraction Analysis (XRD) and Fourier Transform Infrared Spectroscopy (FTIR). After an SEM analysis, a mean of the fiber diameters was performed with ImageJ Software. The antimicrobial activities were evaluated by means of the agar diffusion test. As the PEMA NFs presented smaller diameter, the NF / PEMA standard showed 0.42 μm whereas NF / 20 1.14 μm and the NF / 10 was 0.87μm. The fibers were considered hydrophobic by means of the wettability analysis. The DRX and the FTIR proved a presence of PEMA and suggested a presence of NYS. The diffusion test on agar demonstrated that as fibers failed to inhibit a proliferation of C. albicans / Mestre
77

Análise da estabilidade de cor de botões de íris artificiais obtidos por diferentes técnicas e após o envelhecimento acelerado /

Bannwart, Lisiane Cristina. January 2012 (has links)
Orientador: Marcelo Coelho Goiato / Co-orientador: Daniela Micheline dos Santos / Banca: Mário Alexandre Coelho Sinhoreti / Banca: Eduardo Piza Pellizzer / Resumo: As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. As técnicas existentes para a confecção da prótese ocular devem resultar em íris artificiais perfeitamente estéticas com conseqüente dissimulação do defeito facial. Dessa forma, este estudo tem como propósito verificar a alteração de cor do botão de íris artificial entre diferentes técnicas após a polimerização e o envelhecimento acelerado. Foram confeccionadas 60 amostras simulando próteses oculares distribuídas em grupos (n=10) de acordo com a técnica utilizada, sendo: PE: técnica convencional sem verniz, PEV: técnica convencional com verniz, CA: técnica com calota pré-fabricada sem verniz, CAV: técnica com calota pré-fabricada com verniz, PI: técnica da pintura invertida sem verniz, PIV: técnica da pintura invertida com verniz. A leitura de cor foi realizada por meio de um espectrofotômetro de reflexão ultravioleta visível utilizando o sistema CIE L*a*b*, antes e após polimerização, e após 252, 504 e 1008 de envelhecimento acelerado. Os dados obtidos foram submetidos à análise de variância (ANOVA), e teste de Tukey (p<0,05). O teste de cor mostrou que após polimerização e envelhecimento acelerado todas as amostras apresentaram alteração significativa da cor, porém, as amostras com verniz protetor de tinta tiveram menor alteração em todos os períodos analisados. / Abstract: Ocular prostheses are responsible not only for the recovery of aesthetic but also for the self-esteem of the anophthalmic patient. The techniques used to fabricate ocular prosthesis should result in artificial iris with adequate aesthetic and natural appearance. When such characteristics are not achieved, the fabrication of new prosthesis is indicated even in the presence of good fit of the old prosthesis. Additionally, the color instability of iris is the most relevant factor that affects the longevity of ocular prosthesis, and is related to the polymerization process of the acrylic resin and its clinical use over time. Therefore, the present study investigated the color alteration of artificial iris buttons obtained by different techniques after polymerization and accelerated aging. A total of 60 samples simulating an ocular prosthesis were fabricated and divided into groups (n=10) according to the technique used: PE - conventional technique without varnish; PEV - conventional technique with varnish; CA - Prefabricated cap technique without varnish; CAV - Prefabricated cap technique with varnished; PI - Reverse painting technique without varnish; PIV - Reverse painting technique with varnish. Color measurements were performed by using a visible ultraviolet reflection spectrophotometer with the CIE L*a*b* system, before and after polymerization, and after 252, 504 and 1008 hours of accelerated aging. Data were submitted to analysis of variance (ANOVA) and Tukey test (p<.05). After polymerization and accelerated aging periods all samples exhibited statistically color alteration; however, the varnished samples had lower color change for all periods. / Mestre
78

Avaliação da resistência à fratura de próteses fixas temporárias reforçadas por uma malha experimental /

Almeida, Carolina Souza. January 2015 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Banca: Lafayette Nogueira Júnior / Banca: Alfredo Mikail Melo Mesquita / Resumo: O objetivo no projeto foi avaliar a resistência à fratura de próteses fixas temporárias, com ou sem reforço posicionado em diferentes orientações (horizontal ou vertical), antes e após a termociclagem. Foram confeccionadas 72 próteses fixas temporárias de quatro elementos com resina bis-acrílica, divididas em três grandes grupos: sem reforço, com reforço horizontal e com reforço vertical. Cada grupo foi subdividido em dois, submetidos ou não a ciclagem térmica, totalizando seis subgrupos (n = 12). O reforço consiste em uma malha de nylon revestida por sílica (experimental). Os grupos ciclados receberam 1.000 ciclos térmicos. Todos os espécimes foram submetidos ao ensaio de resistência à fratura em uma máquina de ensaio universal (EMIC), com velocidade de 1,0 mm/min. No segundo experimento foi avaliada a influência do reforço em barras com dimensões de 25 X 10,5 X 3,3mm. As barras foram submetidas à termociclagem como descrito acima e ao ensaio de resistência à flexão 3 pontos, com velocidade de 5mm/min, com celular de carga de 10 KN. A análise estatística foi realizada através dos testes de Kruskal-Wallis Dunn (5%) e demonstrou que a incorporação e a disposição da malha influenciaram a resistência à fratura e a resistência à flexão da resina bis-acrílica foi aprimorada após a adição da malha / Abstract: The aim of this study was to evaluate fracture resistance of temporary bridges as the influence of the addition of a modified nylon mesh in a bis-acrylic resin (Structur 2SC, VOCO, Cuxhaven, Germany). To the first step a temporary fixed prosthesis was made and were analyzed the presence or absence of the fiber and your position (horizontal or vertical). Some groups was subjected to thermal cycling of 1,000 to simulate a temporary fixed prosthesis with extended use period. All specimens were subjected to the test of fracture resistance in a universal testing machine (EMIC DL 1000, EMIC, Brazil), with a speed of 1.0 mm / min. For the second experiment, the test specimens was made in bar shaped (25 x 10.5 x 3.3 mm). The bars were analyzed concerning groups containing or not fibers. Some specimens were subjected to thermal cycling 1,000 cycles. All bars were submitted to the flexural strength by three points bending test in a universal testing machine at constant speed 5 mm/min with load cell of 10 kN. Statistical analysis was performed with Kruskal-Wallis and Dunn tests (5%) and demonstrated that the incorporation and arrangement of the mesh influence the fracture toughness and flexural strength of the bis-acrylic resin was improved afte adding the mesh / Mestre
79

Avaliação da reação tecidual de uma resina termoplástica em tecido subcutâneo de ratos /

Alfenas, Elizabeth Rodrigues. January 1995 (has links)
Orientador: José Roberto Sá Lima / Banca: Plínio Moroni / Banca: Lauro Cardoso Villela / Resumo: A reação tecidual do subcutâneo de ratos foi avaliada por meio da implantação de corpos de prova de uma resina termoplástica (T AK Hydroplastic-DFL). A resina termoplástica foi testada em suas diferentes cores (rosa, amarela, azul e branca). Utilizamos como grupo controle a resina acrílica termicamente ativada incolor. Os corpos de prova em forma de pastilhas, com aproximadamente 8 mm de diâmetro por 1 mm de espessura, foram inseridos em lojas cirúrgicas preparadas no dorso dos animais, que foram sacrificados após os períodos de observação de 2, 3, 6, e 12 semanas. Os tecidos adjacentes aos implantes foram removidos, receberam tratamento histológico de rotina, coloração pela hematoxilina e eosina e pelo tricrômio de Mallory. Os resultados foram analisados por microscopia óptica, e o tecido subcutâneo adjacente aos implantes de resina termoplástica exibiu reação inflamatória moderada nos períodos iniciais de observação (2 e 3 semanas) com reparação da área e formação de cápsula fibrosa envolvendo todos os corpos de prova no período final de 12 semanas. Os resultados obtidos nos permitiram concluir que: • a resina termoplástica nas cores rosa, amarela, azul e branca, não determinou reação tecidual desfavorável em 12 semanas de implantação; • a resina do Grupo controle e a resina termoplástica azul determinaram uma resposta tecidual menos favorável do que a da resina termoplástica nas cores rosa, amarela e branca / Abstract: Subcutaneous rat tissue reaction was evaluated using samples of a thermoplastic resin(TAK Hydroplastic-DFL) of different colours: pink, yellow, blue and white. As control, a transparent thermally activated acrylic resin was used. Samples with a diameter of approximately 8 mm and thickness of 1 mm were implanted in surgical wounds on the back of rats, which were then sacrificed at periods of 2, 3, 6, and 12 weeks. The adjacent tissue was removed and prepared histologically using hematoxilin-eosin and Mallory trichrorne techniques. Through optical microscopy, it was observed that the subcutaneous adjacent to the resin implants showed a moderate inflammatory reaction during the weeks 2 and 3. At the end of week 12, tissue recovery and capsular formation surrounding the resin implant were observed. It was concluded that: • the thermoplastic resin in pink, yellow, b1ue and white colours didn't determine unfavourable tissue reaction in the 12 weeks of implantation; • the resin of the control group and the blue thermoplastic resin determined a tissue response that was less favourable than the thermoplastic resin in pink, yellow and white colours / Mestre
80

Biocompatibilidade de resinas acrílicas para base e reembasamento de próteses após períodos de imersão em soluções desinfetantes : análise do metabolismo celular /

Masetti, Paula. January 2016 (has links)
Orientador: Janaina Habib Jorge / Banca: Ana Carolina Pero Vizoto / Banca: Claudia Helena Lovato da Silva / Resumo: O objetivo deste estudo foi avaliar o efeito cumulativo das soluções desinfetantes na citotoxicidade de resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase II) de próteses. Corpos de prova com 14 mm de diâmetro e 1,2 mm de espessura foram distribuídos em grupos (n=3) de acordo com o tipo de solução: água destilada, digluconato de clorexidina a 2%, perborato de sódio a 3,8%, hipoclorito de sódio a 0,5% e vinagre de maçã, e de acordo com o tempo de imersão: 0, 1, 3 e 6 meses. Os corpos de prova, tanto de base quanto de reembasamento, ficaram 8 horas imersos nas soluções e 16 horas em água destilada, simulando desinfecção noturna das próteses. As soluções foram trocadas diariamente. Após os diferentes períodos de imersão, as amostras foram colocadas em meio de cultura por 24 horas para obtenção de extratos para análise da citotoxicidade sobre queratinócitos humanos (HaCaT: 0341). O metabolismo celular foi avaliado pelo teste Alamar Blue ®. Empregou-se análise de variância (ANOVA) e teste de Tukey, com significância de 5%. Os resultados demonstraram que o tipo de resina não teve influência sobre o metabolismo celular. Além disso, a imersão das amostras de resina acrílica para base e reembasamento de próteses em água destilada, perborato de sódio a 3,8% e hipoclorito de sódio a 0,5% não influenciou o metabolismo celular dos queratinócitos, independentemente do tempo de imersão. Os extratos obtidos a partir da imersão das amostras em digluconato de clorexidina ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the cumulative effect of disinfectant solutions in cytotoxicity base acrylic resins (Vipi Wave) and reline (Tokuyama Rebase II) of dentures. Samples of 14 mm diameter and 1.2 mm thick were distributed in groups (n = 3) according to the type of disinfectant solution: distilled water, 2% chlorhexidine digluconate, 3.8 % sodium perborate, 0.5% sodium hypochlorite and apple vinegar and in accordance with the immersion time: 0, 1, 3 and 6 months. The samples of both base and of reline, eight hours were immersed in solutions and 16 hours in distilled water, simulating night disinfection of prostheses. The solutions were changed daily. After different periods of immersion, the samples were placed in culture medium for 24 hours to obtain extracts for analysis of cytotoxicity on human keratinocyte (HaCaT: 0341). The cellular metabolism was assessed by Alamar Blue ® test. It used analysis of variance (ANOVA) and Tukey test, with 5% significance. The results demonstrated that the resin type had no influence on cellular metabolism. Furthermore, the immersion of the samples in acrylic resin base and reline dentures in distilled water, 3.8% sodium perborate and 0.5% sodium hypochlorite did not influence the cellular metabolism of keratinocytes, regardless of the time of immersion. The extracts obtained from immersing the samples 2% chlorhexidine digluconate or apple vinegar for 3 and 6 months were considered strongly cytotoxic. It was concluded t... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0729 seconds