• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 210
  • 210
  • 112
  • 105
  • 89
  • 68
  • 45
  • 33
  • 28
  • 25
  • 24
  • 23
  • 23
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Comparación de la profundidad de polimerización y grado de conversión de resinas compuestas usando dos unidades de luz visible

Horna Palomino, Hernán January 2019 (has links)
Evalúa la profundidad de polimerización y el grado de conversión por medio de la microdureza superficial interna de dos resinas compuestas de nanorelleno utilizando dos lámparas LED; una de segunda generación y la otra de tercera generación. Metodología. En el estudio in vitro, se obtuvieron 75 especímenes que se dividieron en tres grupos de acuerdo al tipo de resina compuesta, dos resinas de nanorelleno “Tetric N-Ceram” (Ivoclar-Vivadent) y “Filtek Z-350 XT” (3M) y una resina Bulk Fill (grupo control) y cada uno de ellos en tres subgrupos según el tipo de unidad de luz, una unidad de luz “halógena” (grupo control), y dos lámparas de luz emitida por diodos (LED-Valo y LED-Elipar), aplicada sobre el espécimen. Se realizó el análisis estadístico, en donde, las variables fueron sometidas a las pruebas de normalidad y homogeneidad por sus varianzas. Las variables principales no cumplieron con estos supuestos, por lo cual se aplicó la prueba no paramétrica de Kruskal-Wallis. Para encontrar las diferencias entre pares, se aplicó la prueba post-hoc de Dunn. Resultados. Se observó que en las resinas compuestas de nanorelleno no hay diferencias entre los diferentes grupos en relación a la profundidad de polimerización, pero si se observó que la resina Filtek Z350-XT presentó una mejor performance en la microdureza superficial interna como expresión del grado de conversión, utilizando diferentes unidades de luz visible. De la misma forma, las unidades de luz visible en relación a la profundidad de polimerización la LED-Elipar presentan una mejor performance que la LED-Valo, sin diferencias significativas en la microdureza superficial interna como expresión del grado de conversión en los diferentes grupos de resinas compuestas de nanorelleno. Conclusión. Se obtuvo una mejor performance con la LED de segunda generación en profundidad de polimerización con las resinas de nanorelleno y el grado de conversión por medio de la microdureza superficial interna con la lámpara LED de tercera generación con las resinas de nanorelleno. / Tesis
112

Avaliação da resistência à fratura de próteses fixas provisórias implanto-suportadas variando o comprimento do cantilever e o tipo de fibra: fibras de vidro e fibras de poli(aramida) / Evaluation of the resistance to the fracture of temporary fixed prostheses implant-supported varying the extension of the cantilever and the fiber type: glass fibers and poliaramid fibers

Colán Guzmán, Paola del Rosario 01 March 2007 (has links)
No tratamento reabilitador oral as restaurações provisórias são de suma importância. A resistência e a longevidade dos materiais utilizados em sua execução são críticas, principalmente em tratamentos prolongados e em espaços desdentados extensos. O objetivo deste trabalho foi avaliar a resistência e o modo de fratura de espécimes que simularam uma prótese fixa de três elementos variando o comprimento do cantilever (7, 14 e 21mm), confeccionadas em resina acrílica poli(metilmetacrilato) (PMMA) autopolimerizável, com e sem reforço em seu interior, construídos sobre componentes para implantes. Os reforços utilizados foram: fibras de vidro (Fibrante® - Ângelus®, Londrina, PR, Brasil) e fibras de poli(aramida) (Kevlar® - Du Pont®, USA). Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo controle, sem reforço. Os espécimes foram submetidos à carga compressiva até a fratura. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou não haver diferença estatística entre os grupos com respeito ao tipo de reforço, sendo que houve diferença estatística significante no que respeita ao comprimento do cantilever. Quando o comprimento do cantilever foi de 7mm todos os grupos apresentaram os valores médios de resistência a fratura, em N, significativamente maiores que os apresentados pelos grupos com 14 e 21mm de comprimento. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo Parcial. / In the oral rehabilitator treatment, the provisory restorations have extremely importance. The resistance and durability of materials used in the execution are critical, especially in extended treatments and in vast toothless spaces. The goal of this work was to demonstrate the resistance and the types of fracture of specimens that simulate a fixed prosthesis of three elements changing the extension of cantilever (7, 14 e 21mm), made of acrylic resin polymethylmethacrylate (PMMA) autopolymer, with and without reinforcement in its interior, built over implant components. The reinforcements used were: fiberglass (Fibrante® - Angelus®, Londrina, PR, Brazil) and poliaramid fiber (Kevlar® - Du Pont®, USA). The groups have 10 specimens each, including a group of control, without reinforcement. The specimens were submitted to a compressor charge until its fracture. The analysis of results (ANOVA, p < 0,05) for the test of resistance, showed that there is no statistic difference between the groups regarding the type of reinforcement; however, there is a significant statistic difference regarding the cantilever extension. When the extension of cantilever was 7mm, all groups showed medium values of resistance to fractures, in N, significant more than the showed by the groups with 14 and 21mm of extension. In relation with the types of fracture, the reinforcement groups show fractures more favorable to be repaired, even when they were partially fractured.
113

Análise da rugosidade superficial de diferentes marcas comerciais de resina acrílica para coroas provisórias / Surface roughness analysis of acrylic resin for provisional crowns under different commercial brands

Nishida, Cintia Lumi 30 June 2010 (has links)
As coroas provisórias apresentam algumas características que podem comprometer a estética e facilitar aderência de microorganismos e formação de placa. Estudos prévios demonstraram que a forma de processamento influi na rugosidade e porosidade de uma marca comercial de resina acrílica comumente utilizada para a confecção de provisórias. Como diferentes marcas comerciais apresentam diferenças de qualidade, o presente estudo teve como objetivo principal avaliar a rugosidade superficial de quatro marcas comerciais de resina acrílica utilizadas na confecção de coroas provisórias (Dencor, Vipi, Duralay e Alike) de acordo com quatro técnicas de manipulação, diretas e indiretas. Os processamentos avaliados foram: GRUPO I autopolimerização sob pressão em matriz de silicona; GRUPO II - autopolimerização térmica em mufla; GRUPO III autopolimerização utilizando a técnica do pincel; GRUPO IV autopolimerização pela mistura em pote dappen. Para cada tipo de processamento foram confeccionados 12 corpos-deprova de cada material, totalizando 48 corpos-de-prova para cada grupo e 192 espécimes ao total. Logo após a confecção dos espécimes foi realizado o teste de rugosidade de superfície (Ra) através de um rugosímetro/perfilômetro. Posteriormente, a superfície dos mesmos foi uniformizada e polida com a utilização de politriz, realizando-se novamente os mesmos testes de rugosidade. Antes do acabamento e polimento de superfície, os resultados encontrados apontaram a maior rugosidade para resina Vipi (4,074 ± 0,541) e técnica da mistura em dappen gupo IV (3,538 ± 0,509), enquanto que a menor rugosidade foi encontrada para resina Alike (2,671 ± 0,512) e técnica da prensagem em mufla grupo II (2,733 ± 0,470). Após acabamento e polimento, a maior rugosidade foi encontrada para resina Vipi (0,207 ± 0,032) e técnica da pressão grupo I (0,172 ± 0,037), enquanto que a menor rugosidade para resina Alike (0,113 ± 0,036) e técnica da prensagem em mufla grupo II (0,138 ± 0,027). Com os resultados obtidos, foi possível concluir que a melhor combinação para confecção de coroas provisórias em resina acrílica foi a técnica da prensagem em mufla associada à resina Alike. / Provisional crowns have some features that may compromise aesthetics and favors adherence of microorganisms and dental plaque formation. Previous studies have shown that processing may influence roughness and porosity of acrylic resins commonly used make provisional crowns. Because the several commercial resins available present differences in their quality the aim of this study was to evaluate the surface roughness of four commercial brands of acrylic resins (Dencor, Vipi, Duralay and Alike) according to four manipulation techniques (two direct and two indirect): GROUP I - autopolimerization under pressure in a silicone matrix; GROUP II autppolimerization in flask; GROUP III - autopolimerization using the bead brush technique; GROUP IV - autopolimerization after mixing in dappen dish. For each type of processing 12 specimens were made of each material, being 48 specimens for each group and 192 specimens in total. After specimens preparation, surface roughness tests (Ra) was performed using a rugosimeter / profilometer. Posteriorly, all surfaces were polished for standardization and same roughness tests were performed again. Before finishing and polishing, the results pointed out that Vipi resin presented the highest roughness (4.074 ± 0.541). Mixing the resin in dappen dish group IV (3.538 ± 0.509) also presented the highest roughness values regarding the technique. The lowest roughness values were found with Alike resin (2.671 ± 0.512) and flask technique group II (2.733 ± 0.470). After finishing and polishing techniques, the highest roughness was found with Vipi resin (0.207 ± 0.032) and the autopolimetization under pressure in silicone matrix technique - group I (0.172 ± 0.037). The lowest roughness values were found with Alike resin (0.113 ± 0.036) and flask technique group II (0.138 ± 0.027). With these results, it was possible to conclude that the best combination for making provisional crowns was the flask technique associated with Alike resin.
114

Avaliação in vitro da ação do hipoclorito de sódio e de pastilhas efervescentes quanto à alteração de cor em resinas acrílicas termopolimerizáveis e de microondas / In vitro evaluation of sodium hypochlorite and effervescent tablets actionregarding color alteration of heat and microwave-polymerized acrylic resins

Peracini, Amanda 10 July 2008 (has links)
O objetivo deste estudo foi avaliar a alteração de cor de resinas acrílicas termopolimerizáveis (convencional e de microondas) após imersões em soluções químicas higienizadoras de próteses totais em diferentes períodos de tempo. Foram obtidos padrões em cera (15mm de diâmetro e 4mm de espessura), a partir de uma matriz de teflon, que foram incluídos em muflas convencionais e para microondas. Após a eliminação da cera, as resinas foram manipuladas, prensadas e polimerizadas segundo as instruções dos fabricantes. Foram confeccionados 200 corpos-de-prova, 100 de cada marca comercial das resinas Lucitone 550 (L) e Onda Cryl (OC), os quais foram imersos nas soluções: A)Água destilada-3 min.; B)Bony Plus -3 min.; C)Água destilada-5 min.; D)Corega Tabs-5 min.; E)Água destilada-20 min.; F)Hipoclorito de sódio a 0,5%-20 min.; G)Hipoclorito de sódio a 1%-20 min.; H)Água destilada-8 horas; I)Hipoclorito de sódio a 0,5%-8 horas; J)Hipoclorito de sódio a 1%-8 horas. A alteração de cor foi avaliada empregando-se um espectrocolorímetro (Color Guide 45/0 BYK-Gardner) antes e após a simulação de 180 dias de imersão. Os resultados foram comparados por meio da análise de variância (ANOVA) para dois fatores, seguida pelo teste de Student-Newman Keuls, com nível de significância de 0,05. Para correlacionar as diferenças de cor para o ambiente clínico, os dados foram calculados de acordo com as unidades da National Bureau of Standards (NBS). Os resultados mostraram que a resina Lucitone 550 (&Delta;E = 0,47±0,18) apresentou-se mais estável que a Onda-Cryl (&Delta;E = 0,53±0,31). Para ambas as resinas, as pastilhas, os hipocloritos por 20 minutos (0,5% e 1%) e por 08 horas (0,5%) não provocaram alterações maiores que seus respectivos controles (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). As soluções de hipoclorito a 1% (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) causaram maiores alterações que seus respectivos controles. As soluções empregadas por 08 horas (água e Hipocloritos a 0,5% e 1%) provocaram alterações classificadas como leves, segundo o sistema NBS. Os achados deste estudo revelaram que as pastilhas efervescentes, quando usadas de acordo com as instruções dos fabricantes, e o hipoclorito de sódio (0,5% e 1%) por 20 minutos apresentaram menores valores de alteração de cor nas resinas acrílicas após um período de uso simulado de 180 dias. Médias mais elevadas foram obtidas quando um regime de 8 horas foi simulado. / The aim of this study was to evaluate color alteration of heat-polymerized acrylic resins (conventional and microwave-polymerized), after immersion in chemicals solutions of denture cleansers for different periods of time. Wax patterns were obtained (15 mm in diameter and 4 mm thickness) from a teflon matrix and were invested in metallic or microwavable flasks. The wax had been eliminated and the resins were mixed, packed and polymerized according to the manufacturers instructions. Two hundred specimens were made, 100 specimens of each commercial resin Lucitone 550 (L) e Onda Cryl (OC), which were immersed in the solutions: A)Distilled water-3 min.; B)Bony Plus-3 min.; C)Distilled water-5 min.; D)Corega Tabs-5 min.; E) Distilled water -20 min.; F) 0,5% Sodium Hypochlorite-20 min.; G) 1% Sodium Hypochlorite-20 min.; H)Distilled water-8 hours; I)0,5% Sodium Hypochlorite-8 hours; J)1% Sodium Hypochlorite -8 hours. Color alteration was assessed by a spectrocolorimeter (Color Guide 45/0 (BYKGardner) before and after 180 days simulation. The results were analyzed statistically by a two-way analysis of variance (ANOVA), and Student Newman-Keuls test, with significance level of 0.05. To relate the color differences to a clinical environment, the data were quantified by National Bureau of Standards (NBS) units. The results showed that the resin Lucitone 550 (&Delta;E=0,47±0,18) was more stable than the resin Onda-Cryl (&Delta;E=0,53±0,31). For both resins, the tablets, the hypochlorite by 20 minutes (0,5% e 1%) and by 8 hours (0,5%) did not produce higher alterations than the respective controls (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). The 1% hypochlorite solutions (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) produced higher alterations than the respective controls. The solutions employed by 8 hours (water and 0,5% and 1% hipochlorite) produced alterations classified as slight, according to the NBS system. The findings of this study showed that the effervescent tablets, used according to the manufacturer´s instructions, and the sodium hypochlorite (0,5% and 1%) used by 20 minutes presented lower values of color alterations in acrylic resins after a period of 180 days simulation. Higher mean averages were obtained when a period of 8 hours was simulated.
115

Avaliação do comportamento mecânico de próteses fixas provisórias durante e após ensaio de fadiga - efeito de três tipos de reforços (fibra de vidro, fibra de aramida e fio de aço) e duas extensões de pôntico (12,5 e 22,75mm)

Bastos, Luiz Gustavo Cavalcanti 27 June 2006 (has links)
A importância das próteses provisórias no tratamento reabilitador oral é inquestionável. Os materiais utilizados para a execução destas restaurações, entretanto, são críticos com relação à resistência e à longevidade, principalmente quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. A proposta deste trabalho foi determinar através de um ensaio de fadiga e de um teste de resistência à fratura, o efeito do tipo de reforço: fio de aço Ø 0,7 mm, fibra de poli(aramida) (Kevlar®, DuPont - USA) e fibra de vidro (Fibrante®, Ângelus -Brasil) e de duas extensões do pôntico (12,5 e 22,75 mm) sobre o comportamento mecânico de espécimes simulando próteses provisórias. Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo CONTROLE, sem reforço. Os espécimes simulando próteses parciais fixas provisórias foram confeccionados em resina auto-polimerizável com auxílio de uma matriz de aço simulando preparos totais protéticos. As amostras foram submetidas a 10.000 ciclos de fadiga, com carga máxima de 100 N, imersas em água a 37ºC. Através da análise estatística dos resultados observou-se que durante o ensaio de fadiga: 1) quando a extensão do pôntico foi de 22,75 mm, o grupo CONTROLE exibiu uma maior deformação a partir de 500 ciclos. Não foram observadas diferenças quando a extensão do pôntico foi de 12,5 mm. Houve um aumento da deformação em função do número de ciclos para todos os grupos, principalmente para o grupo CONTROLE, de ambas as extensões de pôntico; 2) Somente espécimes do grupo CONTROLE com extensão do pôntico de 22,75 mm demonstraram fraturas à fadiga. E após o ensaio de fadiga, através de um teste de resistência à fratura: 1) Quando a extensão do pôntico foi de 12,5 mm todos os grupos reforçados apresentaram valores médios do limite de elasticidade, em N, significantemente maiores que os demonstrados pelo grupo CONTROLE. Para a extensão do pôntico de 22,75 mm os valores desse parâmetro apresentaram semelhança entre todos os grupos; 2) Em relação à carga máxima (resistência à fratura), quando a extensão do pôntico foi de 12,5 mm o grupo FIBRANTE exibiu o maior valor médio. Quando a extensão do pôntico foi de 22,75 mm, observou-se que o grupo KEVLAR apresentou valores semelhantes neste parâmetro ao grupo FIBRANTE. O grupo CONTROLE sempre apresentou os menores valores médios em ambas as extensões de pôntico. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo parcial (coesiva da resina sem fratura ou separação do reforço). / Provisional restorations are essential components of oral rehabilitation treatment. The strength and durability features are, however, critical when long-term treatment is needed. This study investigates the mechanical alterations under and after cyclic fatigue in provisional partial fixed denture specimens. Two pontic distances (12.5 mm and 22.75 mm) and three types of reinforcements constituted the experimental groups with ten specimens each: a 0.7 mm of diameter wire; a roving poliaramid fiber Kevlar® and a roving fiberglass Fibrante® (Angelus®). The control group, also with ten samples, included not reinforced specimens. Specimens were fabricated and testing on metal dies. The samples were subjected to 10,000 fatigue cycles with a 100 N maximum load in a MTS 810 Universal Machine and before they were subjected to fracture resistance test in the same machine. Statistical analysis showed that, during the fatigue cycles: 1) All the samples exhibited an increased deflection, in mm, following the fatigue cycles, mainly the CONTROL group; 2) Only specimens of the CONTROL group exhibited fracture due to fatigue cycle. After the fatigue cycle, through the fracture resistance test: 1) All reinforced samples with the pontic distance of 12.5 mm exhibited higher figures in elastic limits than the CONTROL group, and increased the pontic distance to 22.75 mm the results of the elastic limits decreased statistically; 3) the FIBRANTE group with pontic distance of 12.5 mm exhibited the higher results for the resistance fracture. The CONTROL group specimens, with both pontic distances, exhibited the lowest values of this property; 4) It was observed that the reinforced FIBRANTE anda KEVLAR groups specimens fractures were more favorable, occurring, predominantly, in the Partial type.
116

Estudo da alteração da dimensão vertical de oclusão (DVO) em dentaduras completas variando-se a fase de inserção da resina acrílica para microondas em mufla e utilizando-se a técnica do propiciador de espaço / Influence of acrylic resin stages and of the space propitiator technique on vertical dimension of occlusion in total dentures

Oshiro, Adriana 21 September 2007 (has links)
As alterações de dimensão vertical de oclusão em dentaduras completas foram avaliadas através da mudança da fase de inserção (arenosa ou pegajosa) da resina acrílica de microondas Onda-Cryl em muflas próprias com a utilização ou não da técnica do propiciador de espaço. Foram confeccionadas dentaduras superiores em cera, corretamente articuladas com uma dentadura inferior previamente montada em articulador semi-ajustável, sendo realizadas as medidas de dimensão verticais iniciais através de um relógio micrométrico. Estas próteses superiores em cera foram divididas em quatro grupos de 10 elementos cada para acrilização: grupo F (inserção da resina acrílica na fase fibrilar em mufla, sem a utilização da técnica do propiciador de espaço), grupo FP (inserção na fase fibrilar, com utilização da técnica do propiciador de espaço), grupo A (fase arenosa, sem a técnica do propiciador de espaço) e grupo AP (fase arenosa, com a técnica do propiciador de espaço). O ciclo de polimerização em todos os grupos foi de 3 minutos a 30% da potência, 4 minutos com 0 (zero) de potência e 3 minutos a 90% da potência, em forno microondas de 800 Watts, conforme as instruções do fabricante. Após a acrilização, as dentaduras superiores, juntamente com seus respectivos modelos, foram remontadas no articulador semi-ajustável (através da técnica do split-cast com imã), onde novas medidas foram tomadas e comparadas com as iniciais. Os resultados foram submetidos à análise estatística e demonstraram que a técnica do propiciador de espaço foi efetiva na diminuição das alterações de dimensão vertical e que a mudança da fase de inserção da resina, embora não estatisticamente significante, também provoca uma redução dessas alterações. / Changes in vertical dimension of occlusion in maxillary complete dentures were evaluated after modifying Onda Cryl acrylic resin insertion stages (sandy or stringy) in specifics flasks or employing or not a space propitiator technique. Forty maxillary wax total dentures were made and randomly assigned in four groups, each one with 10 elements. They were all mounted in a semi-adjustable articulator and the initial vertical dimension measurements were recorded by the means of a gauging device attached to the articulator\'s guideline. The 4 groups were: Group S (Stringy stage, no use of space propitiator technique), Group SP (Stringy stage associated with the space Propitiator technique), Group Sn (Sandy stage, no use of space propitiator technique) and Group SnP (Sandy stage associated with the space Propitiator technique). All specimens were processed in a domestic microwave oven according to Onda cryl manufacturer\'s instructions. After the curing cycle, the flask was removed from the oven, remaining on the bench until its full cooling and the remounted standardized dentures were replaced in the articulator were reevaluated. The vertical dimensional alterations values were submitted to statistical analysis. Space propitiator technique was effective on reducing the vertical dimension alterations and changing the resin stage (sandy instead stringy stage) results in minor alterations on vertical dimension, although not statiscally significant.
117

Síntese, caracterização e efeito microbiológico de nanopartículas de sílica revestidas por prata quando associadas a resina acrílica quimicamente ativada, reembasador macio e ao glaze /

Lucatto, Bruna Corrêa. January 2017 (has links)
Orientador: Tarcisio José de Arruda Paes Junior / Coorientador: Fernando Cristovan / Banca: Lafayette Nogueira Júnior / Banca: João Paulo Barros Machado / Resumo: O objetivo deste trabalho foi sintetizar e caracterizar nanopartículas de sílica recobertas por prata, e avaliar a influência quando incorporadas à resina acrílica quimicamente ativada, ao reembasador macio, e a um glaze, em suas características microbiológicas, microestruturais e mecânicas. Foi confeccionada, pelo método de hidrólise e condensação controlada (método de Stober), uma solução contendo nanopartículas de sílica revestidas por nanopartículas de prata em duas proporções, 10 milimols e 30 milimols, onde as mesmas foram caracterizadas. As nanopartículas de sílica incorporadas com a prata foram analisadas por energia dispersiva de raios-X integrado (EDS), microscopia eletrônica de varredura (MEV), e espalhamento de luz dinâmico (DLS). Para análise microbiológica foram confeccionadas 10 amostras cilíndricas (2mmx10mm), em resina acrílica quimicamente ativada onde as partículas foram incorporadas em duas concentrações: 2.5% e 5% com as duas molaridades diferentes 10 mM e 30 mM. Em outra situação foram confeccionadas 10 amostras cilíndricas (2mmx10mm) de reembasador macio, com concentrações de 2,5% e 5% com as duas molaridades diferentes 10 mM e 30 mM, no terceiro caso as partículas foram acrescentadas a um glaze nas duas concentrações e molaridades e aplicada sob uma amostra de reembasador macio. Uma suspensão de Candida albicans e Estreptococos mutans foi utilizada para análise de concentração inibitória mínima. Amostras retangulares em resina acrílica (n=6) de 30x10x3... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to synthesize and characterize silver - coated silica nanoparticles, and to evaluate the influence when incorporated into chemically activated acrylic resin, soft reliner, and glaze, in their microbiological, microstructural and mechanical characteristics. A solution containing silica nanoparticles coated by silver nanoparticles in two proportions, 10 millimols and 30 millimols, where they were characterized, was prepared by the hydrolysis and controlled condensation method (Stober method). Silica nanoparticles incorporated with silver were analyzed by integrated X-ray dispersive energy (EDS), scanning electron microscopy (SEM), and dynamic light scattering (DLS).For the microbiological analysis, 10 cylindrical samples (2mmx10mm) were made in chemically activated acrylic resin where the particles were incorporated in two concentrations: 2.5% and 5% with two different molarities of 10 mM and 30 mM. In another situation, 10 cylindrical samples (2mmx10mm) of soft reliner were made, with concentrations of 2.5% and 5% with the two different molarities 10 mM and 30 mM, in the third case the particles were added to a glaze in the two concentrations and molarities and applied under a sample of soft reliner. A suspension of Candida albicans and Streptococcus mutans was used for analysis of minimal inhibitory concentration. The samples were made in acrylic resin (n = 6) of 30x10x3mm and were made to perform the three-point flexural strength test of EMIC (Model ... (Complete abstract click electronic access below) / Mestre
118

Efeito da imersão em soluções desinfetantes na capacidade de formação de biofilme de C.albicans e características topográficas de uma resina acrílica para base de prótese e um reembasador /

Amaya Arbeláez, Maria Isabel January 2016 (has links)
Orientador: Janaina Habib Jorge / Resumo: O presente estudo teve como objetivo avaliar a capacidade de formação de biofilme de Candida albicans sobre resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase Fast II) de próteses, após imersão diária por períodos de até 6 meses em soluções desinfetantes. Foram confeccionados 360 corpos de prova circulares de cada resina acrílica usando uma matriz metálica (14 x 1,2 mm). As amostras foram imersas overnight durante 0, 1, 3, e 6 meses em 5 soluções desinfetantes: hipoclorito de sódio 0,5%, perborato de sódio 3,8%, digluconato de clorexidina 2%, vinagre de maçã puro (Minhoto®) e água destilada (grupo controle). Após os diferentes períodos de imersão, um biofilme maduro de 48h de C. albicans (cepa ATCC 90028) foi formado sobre os corpos de prova. A capacidade de formação deste biofilme foi analisada utilizando o método de contagem de colônias (UFC/mL) e o ensaio de viabilidade celular Alamar Blue®. Para todos os grupos experimentais, imagens foram obtidas a partir de microscopia eletrônica de varredura (MEV) para avaliação das características topográficas das resinas após a imersão nos diferentes tempos. Todas os experimentos foram realizados em três ocasiões independentes. Análise de variância de três fatores (ANOVA) foi utilizada para avaliar o metabolismo celular (ensaio Alamar Blue®) e os valores de UFC/mL obtidos a partir da formação do biofilme de C. albicans. Foi adotado o nível de significância de 5%. Os resultados de Alamar Blue® mostraram um efeito... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
119

Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricos

Grando, Antônio Francisco 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
120

Soluções higienizadoras de prótese total: avaliação da remoção de biofilme e efeito sobre propriedades da resina acrílica termopolimerizável / Denture cleansing solutions: evaluation of the biofilm removal and effect on properties of heat-polymerized acrylic resin

Peracini, Amanda 31 May 2012 (has links)
Este estudo avaliou o efeito de soluções higienizadoras de próteses totais quanto ao controle do biofilme (análise clínica) e à alteração de propriedades da resina acrílica (análise laboratorial). A análise clínica foi realizada em 32 desdentados totais que foram orientados a escovar suas próteses (escova Denture e sabonete líquido) três vezes ao dia e imergí-las (&Prime;overnight&Prime;) nas soluções: 1) Controle: Água Natural; 2) Pastilha Corega Tabs; 3) Hipoclorito de Sódio 0,5%. Cada solução foi utilizada por 21 dias (03 ciclos de 07 dias). Ao final de cada ciclo, a superfície interna da prótese superior foi evidenciada (vermelho neutro 1%) e fotografada (HX1- Sony). As áreas (total e corada com biofilme) foram medidas (Image Tool 3.00), sendo a porcentagem de biofilme calculada como a relação entre a área do biofilme multiplicado por 100 e área da superfície total da base interna da prótese. Para a análise laboratorial, foram confeccionados 140 corpos de prova de resina acrílica termopolimerizável (Lucitone 550) que foram imersos por 08 horas nas soluções: 1) Controle 1 (sem imersão); 2) Controle 2 (água destilada); 2) Pastilha Corega Tabs; 3) Hipoclorito de sódio 0,5%, simulando uma higienização diária de 03 anos (1095 dias). Antes e após as imersões, os corpos de prova foram avaliados quanto à alteração de cor (Espectrocolorímetro Color Guide 45/0), rugosidade superficial (rugosímetro Surftest SJ-201P) e resistência à flexão (Máquina Universal de Ensaios DL 2000). Os dados de cor foram também calculados de acordo com a National Bureau of Standards (NBS). As análises estatísticas compreenderam o método de equações de estimação generalizadas (GEE) e comparações múltiplas (Teste de Bonferroni - &alpha; = 1,67%) para análise clínica; e Análise de Variância (ANOVA) e teste HSD de Tukey (&alpha;=0,05) para análise laboratorial. Os resultados clínicos mostraram que a imersão em hipoclorito de sódio 0,5% diminuiu a área coberta por biofilme (8,29 ± 13,26 - B), quando comparado ao controle (18,24 ± 14,91 - A) e à pastilha (18,18 ± 16,62 - A). O hipoclorito (2,75 ± 0,49 - B) e a pastilha (3,01 ± 0,35 - B) provocaram alteração de cor significativamente maior que o controle (0,66 ± 0,29 A), sendo classificadas como perceptível, segundo a NBS. As soluções não alteraram a rugosidade da resina. Houve uma diminuição na resistência à flexão dos grupos pastilha (85,61 ± 10,46 - C) e hipoclorito (82,17 ± 8,47 - C) quando comparados com o controle (sem imersão) (105,4 ± 14,93 - A). O controle (água destilada) apresentou uma redução na resistência à flexão (67,06 ± 11,89 - B). Os achados deste estudo revelaram que a solução de hipoclorito de sódio 0,5% foi a mais efetiva na remoção do biofilme das próteses totais e que ambas as soluções (hipoclorito de sódio 0,5% e peróxido alcalino) não alteraram a rugosidade superficial, porém provocaram alterações de cor classificadas como perceptíveis segundo a NBS, bem como acarretaram uma diminuição da resistência à flexão da resina acrílica termicamente ativada. / This study evaluated the effect of denture cleansers on denture biofilm removal (clinical trial) and changes the properties of acrylic resin (laboratory analysis). A randomized clinical trial was performed in 32 edentulous patients who were instructed to brush their dentures (denture-specific brush and liquid soap) three times a day and to soak them overnight in the solutions: 1) Control: Water; 2) Efervescent Tablet (Corega Tabs); 3) 0.5% Sodium Hypochlorite. Each solution was used for 21 days (03 alternate cycles of 07 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 Sony). Total and stained biofilm areas were measured (Image Tool 3.00), and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. For laboratory analysis, 140 specimens were prepared from heat-polymerized acrylic resin (Lucitone 550) and immersed for 08 hours in the solutions: 1) Control 1 (without immersion); 2) Control 2 (distilled water); 3) Efervescent Tablet Corega Tabs; 4) 0.5% Sodium Hypochlorite, simulating a daily hygiene of 03 years (1095 days). Before and after immersion, specimens were evaluated for color change (portable colorimeter Color Guide 450), surface roughness (Surface Roughness Tester SJ-201P) and flexural strength (universal testing machine DL 2000). Color data were also calculated according the National Bureau of Standards (NBS). Statistical analysis comprised the method of generalized estimating equations (GEE) and multiple comparisons (Bonferroni - &alpha; = 1.67%) for clinical analysis, and analysis of variance (ANOVA) and Tukey&prime;s HSD test (&alpha;=0.05) for laboratory analysis. Clinical results showed that the immersion in sodium hypochlorite 0.5% reduced the area covered by biofilm (8.3 ± 13.3 - B) compared to the control (18.2 ± 14.9 - A) and tablet (18.2 ± 16.6 - A). Hypochlorite (2.8 ± 0.5 - B) and tablet (3.0 ± 0.4 - B) caused significantly higher color change than the control (0.7 ± 0.3 A); such changes were classified as noticeable, according to NBS. The solutions did not alter the roughness of the resin. There was a decrease in the flexural strength of the groups tablet (85.6 ± 10.5 - C) and hypochlorite (82.2 ± 8.5 - C) compared to control (without immersion) (105.4 ± 14.9 - A). The control (distilled water) showed a reduction in flexural strength (67.1 ± 11.9 - B). The findings revealed that the 0.5% sodium hypochlorite solution was the most effective for biofilm removal from complete dentures and that both solutions (0.5% sodium hypochlorite and alkaline peroxide) did not alter surface roughness, but caused color changes classified as noticeable according to the NBS, and resulted in a decrease of flexural strength of heat-polymerized acrylic resin.

Page generated in 0.0936 seconds