• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 10
  • 10
  • 10
  • 10
  • 9
  • 4
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 210
  • 210
  • 112
  • 105
  • 89
  • 68
  • 45
  • 33
  • 28
  • 25
  • 24
  • 23
  • 23
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Efeito do envelhecimento acelerado sobre a microdureza superficial, rugosidade e opacidade de resinas acrílicas incolores termopolimerizáveis e calotas oculares empregadas em prótese ocular, em função da espessura /

Fernandes, Aline Úrsula Rocha. January 2007 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Humberto Gennari Filho / Banca: Stefan Fiuza de Carvalho Dekon / Banca: Mauro Antonio de Arruda Nobilo / Banca: Nuno Filipe D'Almeida / Resumo: As próteses oculares são responsáveis pelo restabelecimento da estética, harmonia facial e auto-estima do paciente anoftálmico. Confeccionados em resina acrílica, os olhos artificiais devem ser estéticos, perfeitamente polidos e resistentes a riscos, características que, quando não satisfeitas, podem gerar transtornos psicológicos, possíveis infecções ou inflamações originárias de substâncias e organismos depositados nas irregularidades superficiais da prótese. O propósito do estudo foi avaliar a microdureza e rugosidade superficiais e opacidade de calotas incolores próprias para prótese ocular e de três marcas de resina acrílica incolor termopolimerizável por banho de água quente de curta e média duração e duas por energia de microondas, em função do envelhecimento acelerado (1008 horas) e espessura (1 e 3,5 mm). Para o estudo, foram obtidas 120 amostras, distribuídas em 12 grupos (n= 10). A análise foi realizada por meio de microdurômetro (Shimadzu Corp., Kyoto, Japão), rugosímetro (TONKA Sul Americana Ltda., SP, Brasil) e espectrofotômetro de reflexão (Shimadzu Corp., Kyoto, Japão). Os valores obtidos antes e após envelhecimento acelerado foram analisados estatisticamente pela Análise de Variância de três fatores e pelo teste de Tukey a 1% de significância. Para o teste de microdureza, as calotas oculares e a resina QC 20 apresentaram, respectivamente, os maiores e menores valores de microdureza superficial, independente da variável avaliada; a espessura não influenciou a propriedade estudada e as amostras apresentaram valores médios de microdureza superficial maiores após o envelhecimento acelerado. / Abstract: Artificial eyes are responsible for reestablishing the facial esthetics, harmony and self esteem of the anophthalmic patient. Made of acrylic resin, artificial eyes must be esthetic, perfectly polished and scratchresistant characteristics which, when not satisfied, may cause psychological disturbances, possible infections or inflammations originating from substances and organisms deposited on the surface irregularities of the prosthesis. The aim of this study was to assess the microhardness, surface roughness and opacity of colorless ocular button for the purpose of use in artificial eyes, and three brands of colorless acrylic resin heat-polymerizable by hot water bath of short and medium duration and two by microwave energy, as a function of accelerated aging (1008 hours) and thickness (1 and 3.5 mm). For this study, 120 samples were obtained, distributed into 12 groups (n=10). Analysis was performed by means of microhardness meter (Shimadzu Corp., Kyoto, Japan), rugosity meter (TONKA Sul Americana Ltda., SP, Brazil) and reflection spectrophotometer (Shimadzu Corp., Kyoto, Japan). The values obtained before and after accelerated aging were statistically analyzed by Analysis of Variance for 3 factors and the Tukey test at 1% significance. For the microhardness test, the ocular buttons and QC 20 resin respectively presented the highest and lowest surface microhardness values, irrespective of the variable assessed; the thickness had no influence on the studied property, and the samples presented higher mean surface microhardness values after accelerated aging. For the roughness test, there was no statistically significant difference with regard to accelerated aging; the resin Vipi Cril, at the thickness of 3.5 mm and ocular button at the thickness of 1 mm presented the lowest roughness value. / Doutor
132

Validação de um método de análise da porosidade em resinas acrílicas para base de prótese /

Pero, Ana Carolina. January 2008 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Débora Barros Barbosa / Banca: Raphael Freitas de Souza / Banca: Adhemar Colla Ruvolo Filho / Banca: João Neudenir Arioli Filho / Resumo: O estudo da porosidade em resina acrílica para base de prótese tem sido realizado por meio de diversos métodos, entre eles o método que associa a porosidade com a sorção de água pela resina acrílica tendo como base o Princípio de Arquimedes. O objetivo do presente estudo foi validar um método de análise da porosidade por meio de sorção de água em resinas acrílicas para base protética por meio da determinação de uma solução adequada de armazenamento dos espécimes (aw ótima), em função de dois formatos de espécime (retangular, de acordo com a norma ISO 1567 e formato de uma base protética) e duas resinas acrílicas para base protética processadas de maneiras distintas: banho de água (Clássico) e microondas (Acron MC). As soluções de armazenamento utilizadas nesse estudo corresponderam a soluções de cloreto de cálcio anidro a 25%, 50%, 75%, e água destilada pura. Após a determinação dos grupos onde se estabeleceu a aw ótima, foram calculados o fator de porosidade (FP) e o coeficiente de difusão (D) nesses grupos bem como para os grupos armazenados em água destilada pura. Os resultados de FP foram comparados por meio de análise de variância (ANOVA) para um fator, seguida pelo teste HSD de Tukey. Para o D, empregou-se o teste de Kruskal-Wallis, seguido do teste de Dunn (Acron MC, P=0,003; Clássico, P=0,020). Para todos os procedimentos estatísticos, o nível de significância foi _= 0,05. A partir dos resultados foi possível concluir que para a resina polimerizada em microondas (Acron MC), a aw ótima é uma solução de cloreto de cálcio anidro a 50% para o formato base protética e de 75% para o formato ISO. Já para a resina polimerizada em banho de água quente (Clássico), concluiu-se que os espécimes para avaliação da porosidade devem ser armazenados em solução de cloreto de cálcio anidro a 75% para o formato base protética e 50 % no formato ISO. / Abstract: The study of porosity in acrylic resin has been carried out by means of diverse methods, among them the method that associates the porosity with the water sorption by acrylic resin which is based on Archimedes' Principle. The aim of the present study was to validate a method of porosity analysis by means of water sorption in denture base resins by the determination of an adequate solution of specimens storage (optimal aw), as a function of two specimen shapes (rectangular in accordance with ISO 1567 and denture base shape) and two denture base resins processed in different ways: water bath (Clássico) and microwave-polymerized (Acron MC). The storage solutions used in this study were anhydrous calcium chloride solutions at 25%, 50%, 75%, and distilled water. After the determination of optimal aw, porosity factor (FP) and diffusion coefficient (D) have been calculated in these groups and for the groups stored in distilled water. FP results have been compared by one-way ANOVA, followed for Tukey HSD test. For D, Kruskal-Wallis test was performed, followed by Dunn test (Acron MC, P=0,003; Clássico, P=0,020). For all the statistical procedures, the level of significance was _= .05. From the results, it was possible to conclude that for Classico resin, the storage solution indicated for porosity evaluation is anhydrous calcium chloride solution at 50% for denture base shape, and 75 % for ISO shape. For the water bath-polymerized resin (Classico), it was concluded that the specimens for porosity evaluation must be stored in anhydrous calcium chloride solution at 75% for denture base shape and 50 % for ISO shape. It was also concluded that, for the same resin, specimen shape did not influence on FP since the specimens are stored in optimal aw established in this study. / Doutor
133

Soluções higienizadoras de prótese total: avaliação da remoção de biofilme e efeito sobre propriedades da resina acrílica termopolimerizável / Denture cleansing solutions: evaluation of the biofilm removal and effect on properties of heat-polymerized acrylic resin

Amanda Peracini 31 May 2012 (has links)
Este estudo avaliou o efeito de soluções higienizadoras de próteses totais quanto ao controle do biofilme (análise clínica) e à alteração de propriedades da resina acrílica (análise laboratorial). A análise clínica foi realizada em 32 desdentados totais que foram orientados a escovar suas próteses (escova Denture e sabonete líquido) três vezes ao dia e imergí-las (″overnight″) nas soluções: 1) Controle: Água Natural; 2) Pastilha Corega Tabs; 3) Hipoclorito de Sódio 0,5%. Cada solução foi utilizada por 21 dias (03 ciclos de 07 dias). Ao final de cada ciclo, a superfície interna da prótese superior foi evidenciada (vermelho neutro 1%) e fotografada (HX1- Sony). As áreas (total e corada com biofilme) foram medidas (Image Tool 3.00), sendo a porcentagem de biofilme calculada como a relação entre a área do biofilme multiplicado por 100 e área da superfície total da base interna da prótese. Para a análise laboratorial, foram confeccionados 140 corpos de prova de resina acrílica termopolimerizável (Lucitone 550) que foram imersos por 08 horas nas soluções: 1) Controle 1 (sem imersão); 2) Controle 2 (água destilada); 2) Pastilha Corega Tabs; 3) Hipoclorito de sódio 0,5%, simulando uma higienização diária de 03 anos (1095 dias). Antes e após as imersões, os corpos de prova foram avaliados quanto à alteração de cor (Espectrocolorímetro Color Guide 45/0), rugosidade superficial (rugosímetro Surftest SJ-201P) e resistência à flexão (Máquina Universal de Ensaios DL 2000). Os dados de cor foram também calculados de acordo com a National Bureau of Standards (NBS). As análises estatísticas compreenderam o método de equações de estimação generalizadas (GEE) e comparações múltiplas (Teste de Bonferroni - α = 1,67%) para análise clínica; e Análise de Variância (ANOVA) e teste HSD de Tukey (α=0,05) para análise laboratorial. Os resultados clínicos mostraram que a imersão em hipoclorito de sódio 0,5% diminuiu a área coberta por biofilme (8,29 ± 13,26 - B), quando comparado ao controle (18,24 ± 14,91 - A) e à pastilha (18,18 ± 16,62 - A). O hipoclorito (2,75 ± 0,49 - B) e a pastilha (3,01 ± 0,35 - B) provocaram alteração de cor significativamente maior que o controle (0,66 ± 0,29 A), sendo classificadas como perceptível, segundo a NBS. As soluções não alteraram a rugosidade da resina. Houve uma diminuição na resistência à flexão dos grupos pastilha (85,61 ± 10,46 - C) e hipoclorito (82,17 ± 8,47 - C) quando comparados com o controle (sem imersão) (105,4 ± 14,93 - A). O controle (água destilada) apresentou uma redução na resistência à flexão (67,06 ± 11,89 - B). Os achados deste estudo revelaram que a solução de hipoclorito de sódio 0,5% foi a mais efetiva na remoção do biofilme das próteses totais e que ambas as soluções (hipoclorito de sódio 0,5% e peróxido alcalino) não alteraram a rugosidade superficial, porém provocaram alterações de cor classificadas como perceptíveis segundo a NBS, bem como acarretaram uma diminuição da resistência à flexão da resina acrílica termicamente ativada. / This study evaluated the effect of denture cleansers on denture biofilm removal (clinical trial) and changes the properties of acrylic resin (laboratory analysis). A randomized clinical trial was performed in 32 edentulous patients who were instructed to brush their dentures (denture-specific brush and liquid soap) three times a day and to soak them overnight in the solutions: 1) Control: Water; 2) Efervescent Tablet (Corega Tabs); 3) 0.5% Sodium Hypochlorite. Each solution was used for 21 days (03 alternate cycles of 07 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 Sony). Total and stained biofilm areas were measured (Image Tool 3.00), and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. For laboratory analysis, 140 specimens were prepared from heat-polymerized acrylic resin (Lucitone 550) and immersed for 08 hours in the solutions: 1) Control 1 (without immersion); 2) Control 2 (distilled water); 3) Efervescent Tablet Corega Tabs; 4) 0.5% Sodium Hypochlorite, simulating a daily hygiene of 03 years (1095 days). Before and after immersion, specimens were evaluated for color change (portable colorimeter Color Guide 450), surface roughness (Surface Roughness Tester SJ-201P) and flexural strength (universal testing machine DL 2000). Color data were also calculated according the National Bureau of Standards (NBS). Statistical analysis comprised the method of generalized estimating equations (GEE) and multiple comparisons (Bonferroni - α = 1.67%) for clinical analysis, and analysis of variance (ANOVA) and Tukey′s HSD test (α=0.05) for laboratory analysis. Clinical results showed that the immersion in sodium hypochlorite 0.5% reduced the area covered by biofilm (8.3 ± 13.3 - B) compared to the control (18.2 ± 14.9 - A) and tablet (18.2 ± 16.6 - A). Hypochlorite (2.8 ± 0.5 - B) and tablet (3.0 ± 0.4 - B) caused significantly higher color change than the control (0.7 ± 0.3 A); such changes were classified as noticeable, according to NBS. The solutions did not alter the roughness of the resin. There was a decrease in the flexural strength of the groups tablet (85.6 ± 10.5 - C) and hypochlorite (82.2 ± 8.5 - C) compared to control (without immersion) (105.4 ± 14.9 - A). The control (distilled water) showed a reduction in flexural strength (67.1 ± 11.9 - B). The findings revealed that the 0.5% sodium hypochlorite solution was the most effective for biofilm removal from complete dentures and that both solutions (0.5% sodium hypochlorite and alkaline peroxide) did not alter surface roughness, but caused color changes classified as noticeable according to the NBS, and resulted in a decrease of flexural strength of heat-polymerized acrylic resin.
134

Avaliação da resistência de união entre dentes artificiais e resinas acrílicas para base protética. Efeito de termociclagem

Marra, Juliê [UNESP] 23 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-23Bitstream added on 2014-06-13T18:58:02Z : No. of bitstreams: 1 marra_j_me_arafo.pdf: 564454 bytes, checksum: ccab0b66e3c9fe8f4225ae09cf3fc905 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O estudo avaliou a resistência de união entre dentes artificiais e resinas acrílicas para base protética e o efeito da termociclagem. Para isso foram utilizadas três marcas comerciais de dentes artificiais de resina acrílica (Biotone, Trilux e Ivoclar) e quatro de resinas acrílicas para base protética, sendo duas termopolimerizáveis por banho de água quente (Lucitone 550 e QC-20), uma polimerizada por meio da energia de microondas (Acron MC) e uma fotopolimerizável (Versyo.com). Vinte espécimes foram confeccionados para cada combinação de dente artificial e resina acrílica e divididos em 2 grupos (n=10) nas seguintes condições experimentais: sem a ação da termociclagem (grupo controle) e com a ação da termociclagem. Os espécimes dos grupos com termociclagem foram submetidos 5000 ciclos com temperatura variando entre 4º e 60ºC e tempo de imersão de 30 segundos em cada. Em seguida, os espécimes foram submetidos ao ensaio mecânico de cisalhamento em máquina universal a uma velocidade de 1mm/min. Os dados foram submetidos à análise de variância a três fatores seguida pelo teste de Bonferroni para comparações múltiplas (a=0,05). Os resultados demonstraram que a termociclagem reduziu significantemente os valores médios de resistência de união da resina acrílica Lucitone 550 quando associada aos dentes Biotone e Trilux e com a resina Versyo.com e os dentes Ivoclar P<0,05). E que as médias de resistência de união das resinas acrílicas Acron MC e Lucitone 550 quando associadas aos dentes Ivoclar aumentaram significantemente após a ação da termociclagem (P<0,05). Conclui-se que algumas combinações de dente artificial e resina acrílica podem ser mais afetadas pela ação da termociclagem, e esses efeitos variam de acordo com os materiais selecionados. / The purpose of this in vitro study was to evaluate the bond strength of denture base resins to acrylic denture teeth and the effect of the thermocycling. Three acrylic denture teeth (Biotone, Trilux and Ivoclar) were chosen for bonding to four denture base resins: one microwave-polymerized (Acron MC), two heat-polymerized (Lucitone 550 and QC-20) and one light-polymerized (Versyo.com). Twenty specimens were produced for each denture base/acrylic denture tooth combination and were divided into 2 groups (n=10) as follows: without thermocycling (control groups) and thermocycled groups that were submitted to 5,000 cycles between 4º and 60ºC with a dwell time of 30 seconds in each bath. Shear strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 1 mm/min until fracture. Statistical analysis of the results was carried out with 3-way ANOVA and Bonferroni's multiple comparisons post hoc analysis for test groups (a=.05). A significant interaction between denture base resin, acrylic denture teeth and thermocycling (P<.001) was observed. The shear bond strengths of Lucitone 550/Biotone, Lucitone 550/Trilux and Versyo.com/Ivoclar specimens were significantly decreased by thermocycling compared with the corresponding control groups (P<.05). The shear bond strengths of Acron/Ivoclar and Lucitone/Ivoclar specimens significantly increased after thermocycling (P<.05). Some acrylic tooth/denture base resin combinations can be more affected by thermocycling; the effects vary based upon the materials used.
135

Análise in vitro do extrato de citronela (Cymbopogon nardus) e de enxaguatórios bucais comerciais sobre propriedades físicas e microbiológicas de materiais utilizados na confecção de prótese tipo protocolo /

Cunha, Bruno Guandalini. January 2017 (has links)
Orientadora: Aimée Maria Guiotti / Coorientadora: Cristiane Duque / Banca: Marcelo Coelho Goiato / Banca: Margarete Teresa Gottardo de Almeida / Resumo: O uso de soluções enxaguatórias é uma ferramenta no controle de patologias relacionadas ao uso de próteses. A efetividade antimicrobiana e citotoxicidade de alguns enxaguatórios comercialmente disponíveis ainda são questionadas, tornando a fitoterapia uma alternativa a ser pesquisada. Sendo assim, este estudo teve como objetivos: 1) avaliar in vitro a eficácia de formulações à base do extrato de citronela (CN) em biofilmes monoespécie em formação e formado, sobre amostras de resina acrílica ativada termicamente (RAAT) e liga de níquel-cromo (LNC), contaminadas por S. aureus e C. albicans, simulando uma prótese protocolo em meio bucal, em comparação com dois enxaguatórios comerciais sem etanol (LT - Listerine Zero e CHX - Periogard sem etanol); 2) avaliar in vitro a citotoxicidade das soluções em células epiteliais HaCat, simulando o contato com os enxaguatórios por 1 min; 3) avaliar, in vitro, o efeito de enxaguatórios bucais comerciais e da solução teste à base do óleo de CN a 10,9%, na alteração de rugosidade e cor de materiais utilizados na confecção de prótese tipo protocolo, sendo eles: duas marcas de dentes artificiais (DA - Trilux e Vivodent), RAAT e LNC. A alteração de cor da LNC não foi avaliada. Para o primeiro objetivo, após a obtenção da concentração bactericida/fungicida mínima (CBM/CFM) da CN contra S. aureus e C. albicans, foram confeccionadas amostras de RAAT e LNC. A CBM/CFM da CN foi multiplicada por 5x e 10x para a formulação de dois enxaguatórios. As super... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of mouthrinses is a tool in the control of pathologies related to the use of prostheses. The antimicrobial effectiveness and cytotoxicity of some commercially available mouthrinses are still questioned, making phytotherapy an alternative to be researched. Therefore, this study aimed: 1) to evaluate in vitro the efficacy of formulations based on the citronella extract (CN) in monospecific biofilms, in formation and formed, on samples of thermally activated acrylic resin (RAAT) and nickel-chromium (LNC), contamineted by S. aureus and C. albicans, simulating a protocol prosthesis in buccal medium, compared to two alcohol free commercial mouthrinses (LT - Listerine Zero and CHX - Periogard alcohol free); 2) to evaluate in vitro the cytotoxicity of solutions in HaCat epithelial cells, simulating contact with the mouthrinses for 1 min; 3) to evaluate in vitro the effect of commercial mouthrinses and the test solution based on the extract of CN at 10.9%, in the alteration of roughness and color of materials used in the manufacturing of protocol type prosthesis; i.e. two tooth marks (DA - Trilux and Vivodent), RAAT and LNC. The color change of the LNC was not evaluated. For the first objective, samples were prepared after obtaining the minimum bactericidal / fungicidal concentration (CBM / CFM) of CN against S. aureus and C. albicans, RAAT and LNC. The CN's CBM / CFM was multiplied by 5x and 10x for the formulation of two mouthrinses. The surfaces of the samples with the biofilm in formation (4 h of adhesion) and formed (24 h) were subjected to the action of solutions based on CN, Periogard alcohol free (CHX) and Listerine Zero (LT). The simulation of mouthwashing was performed at two different moments; the first simulation after the time of adhesion of 4 h (biofilm in formation) and 24 h (formed biofilm), and the second...(Complete abstract click electronic access below) / Mestre
136

Análise in situ da biocompatibilidade da resina acrílica sobre células da mucosa palatina = In situ biocompatibility of acrylic resin in palatal mucosa cells / Taís de Morais Alves da Cunha ; orientador, Odilon Guariza Filho ; co-orientador, Antônio Adilson Soares de Lima / In situ biocompatibility of acrylic resin in palatal mucosa cells

Cunha, Taís de Morais Alves da January 2008 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2008 / Inclui bibliografia / A resina acrílica autopolimerizável utilizada para a confecção de aparelhos ortodônticos apresenta níveis variados de citotoxicidade de acordo com o grau de conversão de seus monômeros. Durante a polimerização, a conversão do monômero em polímero geralmen / Autopolymerized acrylic resin, which is used to prepare orthodontic appliances, shows different levels of cytotoxicity according to the monomer conversion grade. During the curing process, the conversion of monomer into polymer is often incomplete; thus,
137

Biocompatibilidade de primers e adesivo utilizados na confecção de próteses maxilofaciais implantorretidas: análise in vitro

Bonatto, Liliane da Rocha [UNESP] 15 June 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-15. Added 1 bitstream(s) on 2016-02-05T18:34:15Z : No. of bitstreams: 1 000857711.pdf: 1685122 bytes, checksum: 06044cf174850099dc014984d0007cc8 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A prótese bucomaxilofacial implantorretida pode ser suportada por pele ou por mucosa. Subprodutos dos materiais utilizados na confecção destas próteses podem atuar como irritantes ou causadores de reações alérgicas a tais tecidos. A proposta do presente estudo foi avaliar a citotoxicidade de primers e adesivo utilizados na confecção de próteses maxilofaciais retidas por implantes, por meio da análise da proliferação celular e da produção de citocinas pró-inflamatórias e de proteínas de matriz extracelular por queratinócitos humanos. Foram confeccionadas 28 amostras de resina e silicone, em forma de discos (10 x 1 mm), unidas ou não pela aplicação de primer e/ou adesivo. Estas amostras foram distribuídas em 7 grupos: Resina (R), Silicone (S), Resina + Silastic Medhical Adhesive Type A + Silicone (RAS), Resina + DC 1205 primer + Silicone (RDCpS), Resina + Sofreliner primer + Silicone (RSpS), Resina + DC 1205 primer + Silastic Medhical Adhesive Type A + Silicone (RDCpAS) e Resina + Sofreliner primer + Silastic Medhical Adhesive Type A + Silicone (RSpAS). Os extratos dos materiais testados foram preparados colocando-se quatro amostras de cada grupo experimental em tubos de ensaio contendo 9 mL de meio de cultura DMEM (Dulbecco's Modified Eagle's) e incubados a 37°C por 24 horas. Após o período de incubação, a citotoxicidade dos extratos foi avaliada pelo ensaio de MTT em cultura de queratinócitos humanos (HaCaT). Foi avaliada, também, a produção das citocinas IL-1, IL-6 e TNF-α e a quimiocina MIP-1α por meio do ensaio ELISA (Ensaio Imunoabsorbente de Ligação Enzimática). Também foi avaliada a expressão de RNAm para MMP-9, TGF-β e COL-IV por meio da técnica de RT-PCR em tempo real (Reação em Cadeia da Polimerase em Tempo Real). Os dados obtidos foram submetidos à Análise de Variância (ANOVA), seguido... / The implant-retained maxillofacial prosthesis can be supported by skin and mucosa. The sub-products produced by the materials used to fabricate these prostheses may act as an irritant factor and cause allergy in these tissues. The aim of this study was to evaluate the cytotoxic effect of primers and adhesive used to bond the acrylic resin and the facial silicone during implant-retained maxillofacial prosthesis fabrication, through the analysis of the cell proliferation, and the production of proinflammatory cytokines and extracellular matrix proteins by keratinocytes. A total of 28 round shape samples (10 x 1 mm) made of resin and silicone bonded or not with primer and adhesive was fabricated. Samples were divided into 7 groups: Resin (R), Silicone (S), Resin + Silastic Medical Adhesive Type A + Silicone (RAS), Resin + DC 1205 primer + Silicone (RDCpS), Resin + Sofreliner primer + Silicone (RSpS), Resin + DC 1205 primer + Silastic Medical Adhesive Type A + Silicone (RDCpAS), and Resin + Sofreliner primer + Silastic Medical Adhesive Type A + Silicone (RSpAS). Extracts of tested materials were prepared setting four samples of each experimental group in Falcon tube with 9mL of medium (Bulbecco's Modified Eagle's) and incubated at 37°C for 24 hours. After incubation period, the extract cytotoxicity was evaluated by an assay of cell survival/proliferation (MTT test) in cultures of human keratinocytes (HaCaT). The levels of IL-1, IL-6 and TNF-α and the chemokine MIP-1α were evaluated by ELISA (Enzyme-Linked Immunoabsorbent Assay). The mRNA expression for MMP-9, TGF-β and collagen type IV were analyzed by the RT-PCR (Real time polymerase chain reaction). Data were submitted to the analysis of variance with Bonferroni post-tests (p<0.05). The results showed increased cell proliferation for the RAS group. The RDCpS group showed the highest...
138

Quantificação de metacrilatos residuais e avaliação da liberação em saliva artificial a partir de resinas acrílicas para reembasamento imediato

Almeida, Fernando Gonçalves de 21 May 2008 (has links)
Made available in DSpace on 2016-06-02T20:36:17Z (GMT). No. of bitstreams: 1 2116.pdf: 642759 bytes, checksum: e242d729b3245bc7f7270819da7f0b67 (MD5) Previous issue date: 2008-05-21 / Universidade Federal de Sao Carlos / This work reports the development of analytical methods, using High Performance of Liquid Chromatography (HPLC), to quantify unreacted monomers from dental reline autopolimerizing acrylic resins. The quantification of these unreacted methacrylates is directly related with theirs toxicity, once that these may not only be irritant to the mucosa, but may also cause allergic and inflammatory reactions. In addition to this, high concentrations of unreacted monomers may cause alterations in physical and mechanical properties. For this purpose, three experimental resins (RE1, RE2 and RE3) and a commercial resin, Tokuyama Rebase Fast II (TKY), were selected to be analyzed. The development of these experimental resins has been carried out in cooperation with Faculty of Dentistry, Araraquara (FOAr - Unesp) and the dental corporation VIPI Ltda (Pirassununga, SP). The relevance of development these new resins is related to the necessity to have a national confectioned resin, because all resins used for these treatments are imported and reducing the cost of treatment. For quantification of unreacted monomers was necessary to extract them from the resins, so the extraction procedure was carried out in an ice-bath using methanol as extraction solvent. This procedure was validated through extractions in replicates. The monomers quantified were acetoacetoxy ethyl methacrylate (AAEM) from TKY resin, ethylene glycol dimethacrylate (EDMA), buthanediol dimethacrylate (BDMA) and cyclo hexyl metharylate (CHMA) all from experimental resins. Higher concentrations were found for experimental resins which the unreacted monomers concentrations range were, approximately 120&#956;g/mL to 500&#956;g/mL, 150&#956;g/mL to 500&#956;g/mL and 100 to 300&#956;g/mL for resins RE3, RE1 e RE2, respectively Only for TKY resin was carried out a procedure to evaluate the quantity of unreacted monomer leached out in vitro in artificial saliva. There were found concentration in the range from 5.00 to 64.0&#956;g/mL, in view of that the higher concentrations were leached from resin in the first 24 hours and after one week of artificial saliva immersion it was not observed the leaching of AAEM monomer. / Neste trabalho, foram desenvolvidos métodos analíticos, por Cromatografia Líquida de Alta Eficiência (CLAE), para a quantificação de monômeros metacrilatos não polimerizados de resinas acrílicas autopolimerizáveis, utilizadas em tratamentos odontológicos para reembasamento de bases de prótese. A importância da quantificação de metacrilatos residuais está associada à sua toxicidade, uma vez que podem causar reações alérgicas e irritações na mucosa bucal do paciente. Além disso, altas concentrações de monômeros não polimerizados podem comprometer as propriedades físicas e mecânicas da resina e, consequentemente, a qualidade do tratamento de reembasamento. Para isso, foram analisadas três resinas experimentais e uma resina comercial, a Tokuyama Rebase Fast II (TKY). As resinas experimentais (RE1, RE2 e RE3) estão em desenvolvimento pela empresa VIPI Indústria Comércio Exportação e Importação de Produtos Odontológicos Ltda, em colaboração com a Faculdade de Odontologia de Araraquara (FOAr - Unesp). O desenvolvimento dessas novas resinas deve-se à necessidade de se ter uma resina de fabricação nacional, visando reduzir o custo do tratamento, uma vez que as resinas utilizadas para este fim são todas importadas. Para a quantificação de monômeros residuais, realizou-se a extração destes a partir das resinas com metanol refrigerado em banho de gelo, e processo foi validado através de extrações em replicata. Os monômeros quantificados foram: metacrilato de acetoacetoxietil (AAEM - resina TKY), dimetacrilato de butila (BDMA), dimetacrilato de etila (EDMA) e metacrilato de cicloexila (CHMA) - resinas experimentais. As maiores concentrações foram encontradas para as resinas experimentais, nas quais as concentrações de monômeros não polimerizados variaram aproximadamente de 120&#956;g/mL a 500&#956;g/mL, de 150&#956;g/mL a 500&#956;g/mL e de 100 a 300&#956;g/mL para as resinas RE3, RE1 e RE2, respectivamente. A variação encontrada para a resina TKY foi de 70 a 110&#956;g/mL. Para a resina comercial (TKY) foi realizado um estudo no sentido de avaliar a quantidade de monômero não polimerizado e liberado in vitro em saliva artificial. Foram encontradas concentrações de 5,00 a 64,0&#956;g/mL, sendo que os maiores valores foram obtidos nas primeiras 24 horas. Após uma semana de imersão em saliva artificial não se observou a liberação do monômero AAEM.
139

Caracterização de resinas para base de prótese e reembasamento : propriedades físico-químicas e mecânicas /

Lombardo, Carlos Eduardo Leão. January 2013 (has links)
Orientador: Carlos Eduardo Vergani / Co-orientador: José Maurício dos Santos Nunes Reis / Banca: João Neudenir Arioli Filho / Banca: Janaína Habib Jorge / Banca: Rafael Leonardo Xediek Consani / Banca: Cláudia Helena Lovato da Silva / Resumo: Este estudo avaliou propriedades físico-químicas e mecânicas de resinas para base de prótese, uma fotoativada (Eclipse - E) à base de UDMA e outra termicamente ativada por micro-ondas (Nature Cryl MC - NC) à base de PMMA, e um reembasador quimicamente ativado (Tokuyama Rebase Fast II - TR II) à base de PEMA. Propriedades viscoelásticas (E', tan δ e Tg), contração linear de polimerização (CLP), sorção (Sor) e solubilidade (Sol) em água e em saliva artificial, grau de conversão (GC) e coeficiente de inchamento (CI) foram avaliados para a caracterização dos polímeros. A resistência à flexão dos materiais intactos (E, NC, TR II) e reembasados (E-E, E-TRII, NC-NC- NC-TR II) também foi avaliada. As propriedades viscoelásticas foram avaliadas em corpos-de-prova retangulares (64 x 10 x 3,3 mm), submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em dois ciclos de varredura após confecção (controle) e armazenagem em saliva. O módulo de armazenamento (E') e o amortecimento mecânico (tan δ) a 37 ºC e a temperatura de transição vítrea (Tg) foram registrados durante o 1º ciclo da DMTA. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). O coeficiente de inchamento foi realizado (n=5) de acordo com a teoria de Flory-Rhener. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Os dados foram avaliados por ANOVA, seguida por Tukey HSD (α=0,05) ou Dunnett (α=0,05). As resinas E e NC apresentaram similar E', superior a TR II... / Abstract: This study evaluated the physical-chemical and mechanical properties of denture base resins, one UDMA light-activated (Eclipse-E) and one PMMA heat-polymerized (Nature Cryl MC - NC). The PEMA autopolymerizing reliner (Tokuyama Rebase Fast II - TR II) was also evaluated. Viscoelastic properties (E', tan δ e Tg), linear shrinkage polymerization (LPS), sorption (Sor) and solubility (Sol) in water and in artificial saliva, degree of conversion (DC) and coefficient of swelling (CS) were employed for polymer characterization. The flexural strength of intact (E, NC, TR II) and relined samples (E-E, E-TRII, NC-NC- NC-TR II) was also made. The viscoelastic properties were evaluated by two cycles of dynamic mechanical thermal analysis (DMTA) on each rectangular (64 x 10 x 3.3 mm) samples (n=2). The storage modulus (E') and loss tangent (tan δ) at 37 ºC and the glass transition temperature (Tg) were recorded from the 1st DMTA cycle. LPS (%) was evaluated (n=10) by a Nikon 6C optical comparator, on circular samples (50 x 0.5 mm). Sor and Sol (μg/mm3) were measured (n=6) according to ISO 1567. DC (%) was evaluated (n=5) by FTIR spectroscopy (32 scans; resolution 4.0 cm-1). CS was evaluated (n=5) by Flory-Rhener theory. A three-point flexural tests (0.5 mm/min) was applied (n=10) on rectangular intact and relined samples. The ultimate flexural strength (FSU) and the flexural strength at the proportional limit (FSPl) were recorded in MPa. Data were analyzed with ANOVA, followed by Tukey HSD (α=0.05) ou Dunnett (α=0.05). E and NC had similar E', higher than TR II. Tan δ was arranged as TR II > NC > E. The Tg was not affected after saliva storage. The higher Tg values were obtained for E and NC. Tan δ peaks were shifted after 2 DMTA cycles. Regardless the medium immersion, Sor (μg/mm3) was arranged as NC > E > TR II. Saliva storage reduced Sol (μg/mm3) of the materials. E showed the lowest values of LPS, CS and... / Doutor
140

Influência do processamento de próteses totais maxilares com diferentes espessuras da base : análise gráfica da movimentação dos dentes artificiais /

Mazaro, José Vitor Quinelli. January 2005 (has links)
Orientador: Eduardo Piza Pellizzer / Banca: Milton Carlos Gonçalves Salvador / Banca: Humberto Gennari Filho / Banca: Eduardo Piza Pellizzer / Resumo: A relação existente entre os métodos de processamento das resinas acrílicas e a espessura de resina das bases de dentaduras, bem como a associação com o tamanho e forma do arco maxilar, tem sido um assunto bastante discutido no que diz respeito à possíveis alterações no posicionamento dos dentes e selamento posterior de próteses totais maxilares. Sendo assim, o propósito desse trabalho foi avaliar a movimentação dentária que ocorre durante o processamento de próteses totais maxilares com três diferentes espessuras de base, frente a dois métodos de inclusão e submetidas à polimerização por microondas. Quarenta e duas (42) amostras foram aleatoriamente divididas em 6 grupos de 7 amostras cada, respeitando, evidentemente, a espessura da base (1,25 mm - 2,50 mm - 3,75 mm) e o tipo de revestimento em mufla (silicone e gesso pedra). Pontos foram demarcados sobre os dentes artificiais para permitir a mensuração das R ee ssum o amostras através do software AutoCad. A diferença das médias dos segmentos entre o modelo encerado e demuflado de cada grupo foi submetida à analise de variância (ANOVA) e teste de Tukey. De acordo com os resultados obtidos pode-se concluir que: todas as técnicas de processamento juntamente com as diferentes espessuras de base de prótese total avaliadas apresentaram alteração na posição dos dentes artificiais após o processamento. A técnica de inclusão com barreira de silicone foi a que apresentou as maiores alterações dimensionais, independentemente da espessura. Na análise dos segmentos, houve uma maior alteração dos segmentos A/B/C (Triângulo maior) com relação aos segmentos D/E/F (Triângulo menor). Independente do tipo de inclusão, não houve diferença estatística entre as espessuras das bases (p<0,059), entretanto, analisando o comportamento de alteração, as prótese totais com bases mais finas apresentaram maior... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The existent relationship between the methods of processing of the acrylic resins and the thickness of dentures bases resin, as well as the association with the size and form of the maxillary arch, it has been a subject quite discussed with regard to possible alterations in the teeth positioning and maxillary complete denture postdamming. So that, the aim of the study was to evaluate the dental movement that it happens during the processing of maxillary complete dentures with three base thickness different, front of two inclusion methods and submitted to the microwaves polymerization. Forty two (42) samples were randomly divided in 6 groups of 7 samples each, respecting, evidently, the base thickness (1,25 mm - 2,50 mm - 3,75 mm) and the type in flask investment (silicone and plaster stone). Points were demarcated on the artificial teeth to allow the measurement of the samples through the AutoCad software. The averages difference of the segments between the Ab ss tt rr a cc tt waxed model and deflasked of each group was submitted to it analysis of variance (ANOVA – á=0,05) and Tukey test. In agreement with the obtained results it can be conclusion that: all the processing techniques together with the different thickness of complete denture base evaluated, presented alteration in the artificial teeth positionig after the processing. The silicone flasking technique was that presented the largest dimensional alterations, independently of the thickness. In the segments analysis, there was a larger alteration of the segments A/B/C (larger Triangle) regarding the segments D/E/F (smaller Triangle). Independent of the flasking type, there was not difference statistics among the thickness of the bases (p <0,059), however, analyzing the alteration behavior, thinner bases presented larger movement in the position of the artificial teeth than thicken base that complete denture them. The completed... (Complete abstract, click electronic address below). / Mestre

Page generated in 0.0694 seconds