Spelling suggestions: "subject:"resinas composta"" "subject:"tesinas composta""
411 |
Avaliação da influência de um gel a base de peróxido de hidrogênio a 35% sobre a rugosidade superficial de três resinas compostas fotopolimerizáveis de diferentes tamanhos médios de partículas / Evaluation of influence of a gel-based hydrogen peroxide 35% on the surface roughness of three composite resins of different sizes of particlesAndré Fábio Vasconcelos Moro 19 December 2007 (has links)
O clareamento dental se firmou na odontologia como o meio disponível mais simples, comum e conservador de devolver o padrão de cor almejado pelos pacientes. O processo clareador consiste em um ataque a superfície do substrato dentário, provocando pequenas alterações através da quebra de pigmentos, que são longas cadeias de carbono, originando cadeias moleculares cada vez menores até que possam ser eliminadas por difusão. Considerando-se a prática clínica diária nota-se que, algumas vezes, o agente clareador entra em contato com materiais restauradores que ali se encontram, como as resinas compostas por exemplo. Tal procedimento pode ocasionar a indicação de substituição da resina em boas condições clínicas, devido à diferença de cor entre o dente clareado e o compósito. Porém, há casos, como por exemplos: restaurações posteriores e manutenção de clareamento, em que a cor não seria fator decisivo para uma intervenção clínica sobre a restauração. Este estudo avaliou, através de microscopia de força atômica, o efeito de um protocolo de clareamento dentário de consultório a base de peróxido de hidrogênio 35% sobre a rugosidade superficial de três resinas de tamanhos de partículas diferentes (micro-híbrida, microparticulada e nanoparticulada). Vinte e quatro imagens de 5 X 5μm selecionadas aleatoriamente e geradas por microscopia de força atômica foram analisadas estatisticamente por ANOVA e pelo teste SNK (p< 0,05). A análise das topografias demonstrou a resina microparticulada com a menor rugosidade inicial (Rq: 19,22μm e Ra: 14,95μm) e final (Rq: 28,66μm e Ra: 23,06μm), sendo a final semelhante estatisticamente a nanoparticulada inicial (Rq: 29,60μm e Ra: 23,75μm). Seguiram a micro-híbrida inicial (Rq: 35,45μm e Ra: 26,22μm) e a nanoparticulada final (Rq: 40,22μm e Ra: 31,49μm). A resina micro-híbrida final apresentou a maior rugosidade (Rq: 47,41μm e Ra: 36,45μm). Um aumento uniforme e proporcional da rugosidade de superfície nas três resinas testadas foi constatado. Em uma segunda etapa do estudo, a mesma área de superfície foi avaliada antes e depois do procedimento simulador de clareamento e o resultado foi semelhante, porém com a visualização das localidades afetadas. / The bleaching has been in dentistry as the simplest, common and conservative way to return of the pattern of color desired by the patients. The bleaching consists in an attack on dental surface breaking pigments, which are long chains of carbon, causing molecular chains ever smaller until it can be eliminated by diffusion. Considering the practice daily, the bleaching agent contacts restorative materials, such as composite resins for example. This procedure can appoint the replacement of the resin in good clinical conditions due the difference in color between the cleared tooth and composite. But there are cases, for examples: posterior restoratives and maintenance of bleaching, in which color would not be decisive factor for a clinical intervention on the restoration. This study evaluated, through atomic force microscopy, the effect of a memorandum of an in office dental bleaching by hydrogen peroxide 35% on the surface roughness of three types of resins of different sizes of particles (micro-hybrid, microparticles and nanoparticles). Twenty four images of 5 X 5μm randomly selected and generated by atomic force microscopy, were statistically analyzed by ANOVA and the SNK test (p< 0.05). The analysis of topographies showed the microfilled resin with lower initial roughness (Rq: 19.22μm and Ra: 14.95μm) and final roughness (Rq: 28.66μm and Ra: 23.06μm), with the final roughness statistically similar to initial roughness of nanoparticles resin (Rq: 29.60 μm and Ra: 23.75μm). Followed the initial roughness of micro-hybrid resin (Rq: 35.45 μm and Ra: 26.22 μm) and the final roughness of nanoparticles resin (Rq: 40.22μm e Ra: 31.49μm). The final roughness of micro-hybrid resin had the highest roughness (Rq: 47.41 μm and Ra: 36.45 μm). An uniform and proportional increase of surface roughness of the three resins tested was found. A second stage of the study evaluated the same area of surface before and after the procedure simulator of bleaching and the result was the same, with the view of the affected localities.
|
412 |
Avaliação do efeito de diferentes agentes clareadores na rugosidade superficial e estabilidade de cor de dois compósitos / In vitro evaluation of different bleaching agents on the roughness and color stability of two dental compositesAnna Paula Kalix França Mendes 13 February 2009 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar, in vitro, o efeito de dois clareadores a base de peróxido de hidrogênio a 10% e a 35%, Rembrandt Whitening Pen/Oral B e Whiteness HP Maxx/FGM na estabilidade de cor e rugosidade superficial de dois compósitos, sendo um nanohíbrido TPH3/ Dentsply e outro nanoparticulado Filtek Z350/3M ESPE. Foram confeccionados 40 corpos de prova a partir de uma matriz de aço inox com dimensões de 21,0 mm de diâmetro e 2,00 mm de profundidade e divididos em dois grupos conforme o compósito a ser avaliado e submetidos aos seguintes experimentos: Exp. I Ação dos agentes clareadores na estabilidade de cor dos compósitos; Exp. II - Ação dos agentes clareadores na rugosidade superficial dos compósitos; Exp. III - Ação do polimento de superfície na rugosidade superficial e retomada de cor dos compósitos. Tanto a rugosidade como a estabilidade de cor foi avaliada em rugosímetro Mitutoyo SJ 201P e Espectofotômetro de Reflectância Perkin Elmer Lambda 35 UV/VIS respectivamente durante as seguintes etapas do experimento: T0 - após a confecção dos corpos de prova, T1 - após envelhecimento acelerado das amostras por 24 horas por luz ultravioleta, T2 - após submetidas a dois corantes: café e açaí por 7 dias, T3 - após submetidas aos agentes clareadores e T4- após polimento das mesmas. Durante todo o experimento os corpos de prova foram mantidos em saliva artificial e estufa calibrada a 37oC. Os resultados foram tratados estatisticamente por ANOVA e testes de Tukey, comparações múltiplas de Bonferroni e SNK com 5% de significância. Não foram observadas diferenças estatisticamente significantes entre os corantes, o mesmo acontecendo quando os clareadores foram comparados por Teste-t de Student com 5% de significância. Baseado nos resultados obtidos pôde-se concluir que o compósito TPH3 foi mais afetado pelos corantes que o compósito Z350. Os agentes clareadores não foram capazes de promover clareamento dos compósitos nos tempos testados, porém o polimento possibilitou retorno à condição de cor inicial (envelhecida) para o compósito TPH3 o mesmo não acontecendo para o Z350. O polimento não determinou retorno à condição original de rugosidade para qualquer dos compósitos. / The objective of this study was to evaluate, in vitro, the effects of two commercially available bleaching agents containing hydrogen peroxide, Rembrandt Whitening Pen/Oral B and Whiteness HP Maxx/FGM, on the surface roughness and on color change of two composites (TPH3/Dentsply and Filtek Z350/3M ESPE). Twenty specimens of each material were constructed by using a stainless matrix, measuring 21.0 mm diameter and 2.00 mm depth and divided in three groups according the experiments. Group I- effect of the bleaching agents on the composites color change; Group II- effect of the bleaching agents on surface roughness; Group III- effect of polishing procedures on the surface roughness and on color change of the composites. The color measurements were done using a reflectance spectrophotometer Perkin Elmer Lambda 35 UV/VIS according to the CIE L*a*b* color scale and the roughness measurements were obtained using a digital Mitutoyo rugosimeter SJ 201P. The measurements were made in five times: T0: after the specimen preparation; T1: after accelerated aging for 24 hours UV light; T2: after immersed for 07 days at 37o C in either coffee or açaí (a typical fruit of North of Brazil); T3: after bleaching procedures and T4: after finishing and polishing. The results were statistical treated by ANOVA and the differences treated by Tukey, Bonferroni`s test and SNK with 5% of significance. According t-Test with 5% of significance, there were no differences between the staining (coffee and açaí) and neither between the bleaching agents tested. The composite TPH3 showed higher values of discoloration when compared with Filtek Z350, The bleaching agents were not able to improve any kind of whitening on the composites surface. The polishing procedures after bleaching were effective on return the TPH3 to its original color, but they were not capable to return the original roughness of both of the composites.
|
413 |
Comp?sitos Bulk Fill flu?dos versus resinas compostas tradicionais: comportamento mec?nicoChaves, Let?cia Virginia de Freitas 07 July 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-10-05T00:11:28Z
No. of bitstreams: 1
LeticiaVirginiaDeFreitasChaves_DISSERT.pdf: 624609 bytes, checksum: 00e1748d54f2f6578477eb5c68293890 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-10-16T23:12:07Z (GMT) No. of bitstreams: 1
LeticiaVirginiaDeFreitasChaves_DISSERT.pdf: 624609 bytes, checksum: 00e1748d54f2f6578477eb5c68293890 (MD5) / Made available in DSpace on 2017-10-16T23:12:07Z (GMT). No. of bitstreams: 1
LeticiaVirginiaDeFreitasChaves_DISSERT.pdf: 624609 bytes, checksum: 00e1748d54f2f6578477eb5c68293890 (MD5)
Previous issue date: 2017-07-07 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Objetivos: Avaliar a profundidade de polimeriza??o (PP), tens?o de contra??o (TC), resist?ncia flexural (RF), m?dulo de elasticidade (ME) e a resist?ncia de uni?o (RU) de tr?s comp?sitos Bulk Fill fluidos em compara??o a comp?sitos tradicionais de alta viscosidade. Metodologia: Tr?s comp?sitos Bulk fill fluidos (Filtek BKF, Surefil SDR, X-tra Base) e tr?s tradicionais ( Z250 XT, Grandioso, TPH3) foram utilizados. Para RF/ME, 60 amostras (n=10) em forma de barra (7 mm x 2 mm x 1 mm) foram confeccionadas e avaliadas por meio de uma M?quina de Ensaios Universal (MEU). Para PP e RU, cavidades c?nicas (n=10) preparadas em dentina bovina foram restauradas com os materiais. A PP foi analisada atrav?s da raz?o base/topo de microdureza de superf?cie e a RU pelo teste de push-out numa MEU. A TC foi mensurada em incremento ?nico das Bulk Fill e dois incrementos para as tradicionais em MEU acoplada a um extens?metro (n=5). Os dados foram estatisticamente avaliados por meio dos testes ANOVA 2 fatores e Tukey (p<0,05). Resultados: Para ME, as resinas convencionais apresentaram maiores valores diante de todas as resinas BKF, no entanto para a RF elas foram iguais, com exce??o apenas da BKF da VOCO que foi inferior. Para a PP convencionais e BKF foram estatisticamente semelhantes. Na TC e na RU as BKF apresentaram-se superiores as convencionais, tamb?m com exce??o apenas da Xtra Base Bulk Fill (VOCO) que foi estatisticamente igual as convencionais na RU. Conclus?o: As resinas Bulk Fill flu?das testadas BKF e SDR apresentaram as propriedades mec?nicas testadas superiores ou iguais aos comp?sitos tradicionais, exceto o m?dulo de elasticidade. / Objectives: To evaluate depth of polimerization (DP), contraction strress (SC), flexural strenght (FS), elastic modulus (EM) and bond strength (BS) of three low-viscosity Bulk Fill composites resin compare as of high-viscosity traditional composites. Methods: Three Bulk fill composites (Filtek BKF, Surefil SDR, X-tra Base) and three traditional ( Z250 XT, Grandioso, TPH3) were used. For FS/ME, 60 (n=10) bar specimens (7 mm x 2 mm x 1 mm) were prepared and evaluated with Universal Testing Machine (UTM). For DP e BS, conical cavities (n=10) were prepared in bovine dentine and restored with materials. DP was analyzed trough the ratio base/top with microhardness of surface and BS on the push-out test in UTM. SC was measured for to increment one of Bulk Fill Resins and two increments of traditional resins in UTM attached to a extensometer (n=5). The data were statistically evaluated by ANOVA 2-way/Tukey (p<0,05). Results: For EM the conventional resins show higher values compare to all the BKF resins, however for the FS they were the same, except for only the VOCO Bulk Fill that was inferior. For the PP, conventional and BKF were statistically similar. In TC and in BS the BKF were superior to conventional, also with the exception of Xtra Base Bulk Fill (VOCO), which was statistically the same as the conventional ones in the BS. Conclusion: The Bulk Fill composites resin BKF and SDR present most of property physical and mechanical higher or similar than traditional composites, except the elastic modulus.
|
414 |
Efeito da contração de polimerização em restaurações diretas em resinas compostas em dentes posterioresBicalho, Aline Aredes 18 August 2014 (has links)
Fundação de Amparo a Pesquisa do Estado de Minas Gerais / The composite resins have been widely used over years in posterior restorations. However, the composite resins have an inherent characteristic called polymerization shrinkage which may be associated with undesirable clinical manifestations such as post-operative sensitivity, microleakage and recurrent caries. The aim of this study was to investigate the influence of some factors such as occlusal loading, restorative technique, mechanical properties of materials, use of liner and environment conditions on the biomechanical behavior of direct composite resin restorations in posterior teeth through laboratory and computational studies. This study was divided into five specific objectives; objective 1: To investigate the effect of occlusal loading and mechanical properties of composites on shrinkage stress in premolars; objective 2: To investigate the effect of environmental conditions, such as temperature and humidity, mechanical properties on biomechanical behavior of molars with class II MOD; objective 3: to investigate the effect of glass ionomer resin liner and filling technique on biomechanical behavior of class II MOD composite resin restoration, specifically analysing cuspal strain by strain gage test, termal and mechanical fatigue and fracture resistance; objective 4: to investigate the effect of the same parameters of objective 3 on mechanical properties of restorative materials, marginal adaptation and shrinkage stress distribution; objetivo 5: To generate an article with all conclusions about shrinkage and posterior restorations by the Brazilian clinical communication contributing with the social function of knowledge generation. The methods used on the all studies were cuspal strain by strain gage test, post-gel measurments by strain gage test, thermal and mechanical fatigue, fracture resistance, marginal adaptation and fracture mode under scanning electron microscopy, dynamic indentation test for calculation of Vickers Hardness and elastic modulus, indentation test for hardness Knoop calculation, finite element analysis 2D and 3D. After data analysis it can be concluded that materials with higher elastic modulus cause greater shrinkage stress; occlusal loading on the margin of restoration cause great stress concentration at interface; occlusal stable contact in the center of restoration cause low stress concentration; high temperature and humidity affect the post-gel shrinkage, elastic modulus, cuspal strain, bond strength and stress shrinkage in the teeth restored with direct composite resins; the simulation of oral environment should be performed in laboratory tests to evaluate the shrinkage and cuspal strain; the order of filling technique, represented by sequence of the oblique increments, had no influence the cuspal strain, fracture resistance, fracture mode, marginal adaptation and stress distribution in molars restored with composite resin; cuspal strain and shrinkage stress decreased significantly with the presence of resin modified glass ionomer resin liner in direct posterior composite resin restorations; the fracture resistance and fracture mode was not influenced by the presence of liner in molars restored with composite resin; gingival margin had higher gap formation than proximal margins in molar restored with direct composite resin restoration. / As resinas compostas tem sido amplamente utilizadas ao longo dos anos nas restaurações de dentes posteriores. No entanto, os materiais resinosos apresentam característica inerente, a contração de polimerização que pode ser associada à manifestações clínicas indesejáveis como sensibilidade pós-operatória, infiltração marginal e cáries recorrentes. O objetivo geral deste estudo foi investigar a influência de fatores como carregamento oclusal, propriedades mecânicas dos materiais, uso de forramento cavitário, condições de ambiente e técnica restauradora no comportamento biomecânico de restaurações em resina composta em dentes posteriores por meio de estudos laboratoriais e computacionais. Este estudo foi dividido em cinco objetivos específicos; objetivo 1: investigar o efeito da condição de carregamento oclusal e das propriedades mecânicas de resinas compostas nas tensões de contração de polimerização de resinas compostas em pré-molares; objetivo 2: investigar o efeito das condições ambientais, determinadas pela temperatura e umidade, nas propriedades mecânicas e no comportamento biomecânico de molares com restaurações diretas extensas em resina composta; objetivo 3: investigar o efeito do uso de base de ionômero de vidro como protetor pulpar e da técnica de inserção de resina composta no comportamento biomecânico de restaurações molares com restaurações diretas extensão em resina composta, especificamente na deformação de cúspide em diferentes momentos e o reflexo na resistência à fratura; objetivo 4: investigar o efeito dos mesmos parâmetros avaliados no objetivo 3 nas propriedades mecânicas dos materiais restauradores, adaptação marginal e geração de tensões de contração de polimerização; objetivo 5: gerar síntese dos achados dos objetivos 1, 2, 3 e 4 em um artigo de comunicação aos clínicos brasileiros cumprindo a função social da geração do conhecimento. Os métodos experimentais utilizados foram extensometria para deformação de cúspide e para cálculo de contração pós-gel, fadiga térmica e mecânica, resistência à fratura, teste de microtração, microscopia eletrônica de varredura para análise de modo de fratura e adaptação marginal, teste de indentação dinâmico para cálculo de dureza Vickers e módulo elástico, teste de indentação para cálculo de dureza Knoop, análise por elementos finitos 2D e 3D. Após análise estatística dos resultados pode-se concluir que materiais com maiores valores de módulo elástico causam maiores tensões de contração; contato oclusal localizado na margem da restauração de resina composta posterior aumentam as tensões geradas na interface; o carregamento oclusal aumenta os níveis de tensões em dentes restaurados mesmo quando utilizados resinas composta de baixos valores de contração de polimerização; contatos oclusais estáveis no centro da restauração resultaram em melhor distribuição de tensões; umidade e temperatura que simulam as condições de ambiente oral afetam significativamente a contração pós-gel, módulo de elasticidade, deformação de cúspide, resistência adesiva e tensões de contração em dentes com restaurações diretas em resinas compostas; simulação do ambiente bucal deve ser realizada nos testes de laboratório para avaliar estes parâmetros biomecânicos; a ordem de preenchimento dos incrementos de resina composta, se iniciado pelas caixas proximais ou pela cúspide vestibular, não influenciou na deformação de cúspide, resistência à fratura, modo de fratura, adaptação marginal e tensões geradas de molares restaurados com resina composta; a deformação de cúspide e as tensões de contração diminuíram com a presença de ionômero de vidro modificado por resina usado como material de proteção do complexo dentinho-pulpar em restaurações posteriores; a resistência à fratura e modo de fratura não foram influenciados pela presença de material de base em molares restaurados com resina composta; a margem restauradora com maior desadaptação em molares classe II MOD é a margem gengival. O clínico deve se ater as condições de controle técnico e fazer uso de materiais restauradores adequados em termos de propriedades mecânicas e contração de polimerização objetivando potencializar o sucesso de restaurações diretas em resina composta em dentes posteriores. / Doutor em Odontologia
|
415 |
Influência de cimentos resinosos autoadesivos na deflexão de cúspides e carga de fratura de pré-molares restaurados com inlays em resina compostaSalaverry, Aurélio January 2011 (has links)
Made available in DSpace on 2011-12-27T14:14:33Z (GMT). No. of bitstreams: 2
000431091-0.pdf: 6484611 bytes, checksum: ee0b40e71498d6a5f8496211522ca10f (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate the influence of four resin cements (one conventional and three self-adhesive) on cuspal deflection, fracture load and failure mode of endodontically treated teeth restored with composite resin inlays. Seventy-two maxillary premolars were randomly divided into four groups: G1 - sound teeth (control); G2 - cavities without restoration; G3 - RelyX ARC; G4 - RelyX U100; G5 - Maxcem Elite; G6 - SeT. The teeth from groups 2, 3, 4, 5 and 6 received mesio-occlusal-distal preparations and endodontic treatment. Impressions were made with vinyl polysiloxane and poured using type IV die stone in groups 3, 4, 5 and 6. Inlays with Z350 XT composite resin were built over each cast and luted with the resin cements. After storage in water at 37o C for 72 hours, a 200-N load was applied on the occlusal face using an 8 mm diameter metal sphere, and the cuspal deflection was measured using a micrometer. Following, the specimens were submitted to 500,000 cycles of mechanical fatigue, and the cuspal deflection was measured again. The specimens were then submitted to an axial load until failure. According to Kruskal-Wallis, group 2 (69 μm) had the highest cuspal deflection before mechanical fatigue, and did not differ statistically from group 6 (51 μm). Group 1 (4 μm), group 3 (4 μm) and group 4 (5 μm) obtained the lowest cuspal deflections, and did not differ between them. Intermediate value was obtained for group 5 (21 μm), and this group did not differ statistically from groups 3, 4 and 6. According to Wilcoxon test, there was no statistically difference between the cuspal deflection before and after mechanical fatigue only for group 3 (p=0,015). According to Kruskal- Wallis, group 1 (1902 N) had the highest fracture load, and differed statistically from the other groups. The second highest value was obtained for group 3 (980,8 N), and differed statistically from the other groups. Group 4 (670,6 N), group 5 (533,5 N), group 6 (601,3 N) and group 2 (526,6 N) did not differ between them. There was a predominance of recovery fractures for the restored groups. Composite resin inlays luted with RelyX ARC kept the cuspal deflection stability, obtained higher strength of the teeth, as well as fractures with good prognosis for rehabilitation. / O objetivo desse estudo foi avaliar a influência de quatro cimentos resinosos (um convencional e três autoadesivos) na deflexão de cúspides, carga de fratura e tipos de fratura de pré-molares com acesso endodôntico e restaurados com inlays em resina composta. Setenta e dois primeiros pré-molares foram divididos aleatoriamente em seis grupos (n=12): G1 (controle) - hígidos; G2 – cavidades sem restauração; G3 –RelyX ARC; G4 –RelyX U100; G5- Maxcem Elite; G6 –SeT. Os Grupos 2-6 receberam preparos cavitários MOD e acesso endodôntico. Os grupos 3-6 foram moldados com silicona por adição e vazados com gesso especial para confecção de inlays em resina composta Z350 XT. As restaurações indiretas foram cimentadas nas respectivas cavidades com carga de 1 Kg e fotoativadas. Após armazenagem em água destilada a 37º C por 72 horas, carga de 200 N foi aplicada na região oclusal com uma esfera de 8 mm de diâmetro acoplada na máquina de ensaio universal EMIC DL 2000, sendo medida a deflexão de cúspides com um micrômetro digital. Os corpos de prova foram então submetidos a 500. 000 ciclos de fadiga mecânica, e novo teste de deflexão de cúspides foi realizado. Em seguida, os corpos de prova foram submetidos ao ensaio de compressão até a fratura na máquina de ensaio universal. De acordo com o teste de Kruskal-Wallis, a maior deflexão de cúspides pré-fadiga foi obtida para o grupo 2 (69 μm), não diferindo estatisticamente do grupo 6 (51 μm). As menores deflexões de cúspides foram obtidas para o grupo 1 (4 μm), o grupo 3 (4 μm) e o grupo 4 (5 μm), os quais não diferiram estatisticamente entre si. Valor intermediário foi obtido para o grupo 5 (21 μm), não diferindo estatisticamente dos grupos 3, 4 e 6. De acordo com o teste de Wilcoxon, não houve diferença estatística entre a deflexão de cúspides pré e pós-fadiga apenas para o grupo 3 (p=0,015). De acordo com Kruskal-Wallis, a maior carga de fratura foi obtida para o grupo 1 (1902 N), diferindo estatisticamente dos outros grupos. Segundo maior valor foi obtido para o grupo 3 (980,8 N), diferindo estatisticamente dos outros grupos. Grupo 4 (670,6 N), grupo 5 (533,5 N), grupo 6 (601,3 N) e grupo 2 (526,6 N) não diferiram estatisticamente entre si. Para os grupos restaurados, houve predominância de fraturas recuperáveis. Inlays em resina composta cimentadas com RelyX ARC mantiveram a estabilidade da deflexão de cúspides, proporcionaram maior recuperação da resistência da estrutura dentária, assim como fraturas mais favoráveis para a reabilitação.
|
416 |
Influência dos remanescentes dentários e de resinas compostas nos níveis de cinza de dentes em radiografias digitaisGraziottin, Luiz Felipe Rodrigues January 2009 (has links)
Made available in DSpace on 2011-12-27T14:14:23Z (GMT). No. of bitstreams: 2
000409857-0.pdf: 3768332 bytes, checksum: 510f89bdc41453b63f0fecf44ffcf27c (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study investigates how, through digital radiography, the averages in gray levels are expressed in different sites of teeth restored with composite resins in varying thicknesses and what the possible reasons are for the values found. This study comprises a selection of ten healthy first premolars whose roots were embedded in prisms with rectangular bases, then radiographed according to standard procedure by using DenOptix digital optic plates, and whose were digitalized and filed for further analysis. Such samples formed group 1. Each time those teeth received some type of treatment which altered their original shape, a new group was formed. The teeth underwent a standard cavity preparation with a 2mm B-P thickness and were radiographed one more time. Their images were filed, thus forming group 2. The cavities were then restored with Filtek™Z350 composite resins and the teeth were radigraphed again and their digital images filed, thus forming group 3. Such restorations were then removed from their corresponding cavities and the teeth were restored one more time with 4Seasons resin, later radiographed, and their digital images were filed, thus forming group 4. After the restorations were removed, the cavities they once filled were restored with Filtek™Z250 resin. The radiography and filing steps were repeated one more time, thus forming group 5. After the restorations were removed, the cavities’ V-P widths were enlarged by 3mm, and the same steps applied to the previous groups were repeated, thus forming groups 6, 7, 8 and 9. After the removal of the restorations from group 9, the cavities’ V-P widths were enlarged by 4mm, and the same procedures applied to the previous groups were repeated, thus forming four new groups: 10, 11, 12 and 13.Thirty acrylic plates were also manufactured whose thicknesses varied between 2, 3 and 4mm, ten plates of each thickness – each plate contained one sample of each resin. The digital images of plates forming groups 14, 15 and 16 were subject to the same process of radiography and filing aforementioned. Samples of each composite resin were analyzed by EDS for verification of chemical elements responsible for these materials’ radiopacity traits. After the statistical analysis of the data rendered by these procedures, it was possible to conclude that: (1)There were significant differences between the readings sites. (2)The smallest averages in gray levels were found in the teeth with the largest preparations and without filings (G10 - 4mm). (3)The biggest averages in gray levels with the teeth restored with the 4Seasons® resin were found within the greatest restoration thickness (4mm - G12). (4)The teeth with cavities had lower averages in gray levels than the healthy dental tissues. (5)The restored teeth showed higher averages in gray levels than the healthy dental tissues, with the exception of the Filtek™Z350 Resin in the proximal sites of the 3mm restorations. (6)The restored teeth displayed higher averages in gray levels than the ones with cavity preparation but no filings. (7)There were different values for the averages in gray levels between the various composite resins studied when they were analyzed individually, without the interference of dental tissues (plates) and in the same thickness. (8)For the composite resins without the influence of dental tissues, the greater the thickness meant the higher the average in gray levels. (9)The values in gray levels for the restored teeth did not always change in accordance with the changes in gray levels for the composite resins individually analyzed (plates) in the corresponding thickness. (10)The higher concentration of chemical element with a higher atomic number translated into higher averages in gray levels for the composite resins. / Este trabalho teve como objetivo verificar, através da radiografia digital, como se expressam os valores médios, em níveis de cinza, em diferentes sítios de dentes restaurados com resinas compostas em diversas espessuras e quais as possíveis justificativas para tais valores encontrados. Para tanto foram selecionados 10 primeiros pré-molares hígidos, que tiveram suas raízes incluídas em prismas de base quadrangular, sendo radiografados por técnica padronizada utilizando placas ópticas do sistema digital DenOptix, as quais foram digitalizadas e arquivadas para posterior análise. Estas constituíram o grupo 1. Cada vez que estes dentes recebessem algum tratamento, que alterasse a sua forma original, se constituiria um novo grupo. Os dentes passaram por preparo cavitário padronizado com espessura V-P de 2mm, foram novamente radiografados e as imagens digitais arquivadas, constituindo o grupo 2. As cavidades foram restauradas com resina composta Filtek™Z350, os dentes foram novamente radiografados e as imagens digitais arquivadas, constituindo o grupo 3. Essas restaurações foram destacadas das cavidades e os dentes novamente restaurados com a resina 4Seasons, radiografados e as imagens digitais arquivadas, constituindo grupo 4. Após as restaurações serem destacadas, essas cavidades foram mais uma vez restauradas, agora com a resina Filtek™Z250, repetindo-se as radiografias e o arquivamento das imagens digitais, constituindo o grupo 5. Após a remoção dessas restaurações as cavidades foram ampliadas na largura V-P para 3mm, repetindo-se a mesma seqüência realizada nos grupos anteriores, constituindo os grupos 6, 7, 8 e 9. Após a remoção das restaurações do grupo 9, as cavidades foram ampliadas na largura V-P para 4mm, repetindo-se a seqüência realizada nos grupos anteriores, constituindo novos grupos: 10, 11, 12 e 13.Também foram confeccionadas 30 placas acrílicas nas espessuras de 2, 3 e 4mm, 10 placas em cada uma das espessuras, sendo que as placas continham uma amostra de cada resina. Estas constituíram os grupos 14, 15 e 16 que passaram pelo mesmo processo de radiografia e arquivamento das imagens digitais. Amostras de cada uma das resinas compostas foram analisadas pelo EDS, para verificação dos elementos químicos responsáveis pelas características de radiopacidade desses materiais. Após análise estatística dos dados foi possível concluir que: (1)existiu diferença significativa entre os sítios de leitura. (2)Encontraram-se os menores valores médios em níveis de cinza nos dentes com maiores preparos cavitários sem restaurações (G10 - 4mm). (3)Encontraram-se os maiores valores médios, em níveis de cinza, nos dentes restaurados com a resina 4 Seasons® na maior espessura de restauração (4mm - G12). (4)Os dentes cavitados apresentaram valores médios, em níveis de cinza, inferiores aos das estruturas dentárias hígidas. (5)Os dentes restaurados apresentaram valores médios, em níveis de cinza, superiores aos das estruturas dentárias hígidas, com exceção da resina Filtek™Z350 nos sítios proximais das restaurações na espessura de 3mm. (6)Os dentes restaurados apresentaram valores médios, em níveis de cinza, superiores aos dos dentes com preparos cavitários sem restaurações. (7)Houve distinção entre os valores médios, em níveis de cinza, para as diferentes resinas compostas estudadas quando analisadas individualmente, sem influência dos tecidos dentários (placas) em uma mesma espessura. (8)Para as resinas compostas sem a influência dos tecidos dentários, quanto maior foi a espessura, maior o valor médio em níveis de cinza.(9)Os valores em níveis de cinza para os dentes restaurados nem sempre alteraram-se conforme as alterações em níveis de cinza das resinas compostas analisadas individualmente (placas) na espessura correspondente. (10)A presença de maior concentração do elemento químico de mais alto número atômico refletiu-se em maiores valores médios, em níveis de cinza, nas resinas compostas.
|
417 |
Influência da variação da intensidade de luz, para uma mesma exposição radiante, no comportamento mecânico de uma resina convencional e de uma resina de baixa contração / Influence of photoactivation modes, with the same radiant exposure, on mechanical properties of a convencional and a low-shrinkage compositeMariana Rodrigues Gonzalez 08 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo avaliar a influência da variação da intensidade de luz, para uma mesma exposição radiante, na resistência à flexão, na microdureza e na resistência à tração diametral de uma resina convencional e de uma resina de baixa contração. Para a confecção dos corpos de prova foram utilizadas as resinas Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) fotoativadas por meio dos seguintes protocolos: Convencional (400mW/cm por 60 s), Média intensidade (700mW/cm por 34 s) e Alta intensidade (950mW/cm por 26 s). Todos os corpos de prova receberam a mesma exposição radiante de 24J/cm. A resistência à flexão foi avaliada por meio do ensaio de flexão três pontos. Para este ensaio foram confeccionados trinta corpos de prova de cada material (n=10) com dimensões de 10mm x 2mm x 1mm. A avaliação da microdureza Knoop foi obtida a partir de seis discos de cada resina com 5mm de diâmetro por 2mm de espessura (n=2), sendo realizadas cinco indentações em cada espécime. Trinta corpos de prova cílindricos de cada compósito (n=10) com 3mm de diâmetro por 6mm de altura foram confeccionados para a realização do teste de tração diametral. A análise estatística dos resultados obtidos foi realizada por meio do teste de análise de variância (ANOVA) e do teste de múltiplas comparações de Tukey (p < 0.05). A resistência à flexão da resina P90 não foi influenciada de forma significativa pelas diferentes formas de ativação, enquanto a Z250 obteve resultados significantemente maiores para o protocolo de alta intensidade em relação ao convencional. Em todas as intensidades de luz, os resultados da Z250 foram significativamente maiores que os da P90. A microdureza da resina P90 foi estatisticamente maior para o grupo de média intensidade em relação aos outros, já a Z250 não obteve resultados com diferença estatística em relação às formas de ativação. Para a mesma irradiância, a Z250 obteve maiores valores de microdureza do que a P90, com exceção para o protocolo de média intensidade em que não houve diferença estatística entre os materiais. Os valores de resistência à tração não foram influenciados de forma significativa nem pelas diferentes intensidades de luz, nem pelos materiais utilizados. A influência da variação da intensidade de luz depende do tipo de compósito utilizado e da propriedade mecânica avaliada. / This study has the purpose of evaluating the variation of the intensity of light, for a constant radiation exposure, for flexural strength, for microhardness, and for tensile strength, of a conventional composite and a low shrinkage composite. The test samples were made of Filtek Z250 (3M ESPE) e Filtek P90 LS (3M ESPE) light-activated composites. The following light activating protocol was used: conventional (400mW/cm for 60 s); medium intensity (700mW/cm for 34 s), and high intensity (950mW/cm for 26 s). All of the test samples received the same radiation exposure of 24J/cm. The flexural strength was measured through the three-point bending test. For this test, thirty especimens were made for each material (n=10), measuring 10mm x 2mm x 1mm. The Knoop hardness evaluation was carried out using six discs of each composite measuring 5mm in diameter, and 2mm in height (n=2), with five indentations in each specimen. Thirty cylindrical test samples of each composite (n=10) measuring 3mm in diameter, and 6mm in height were obtained for the diametral tensile test. The statistical analysis of the results was carried out through analysis of variance test (ANOVA) and through Tukeys multiple comparisons test (p < 0.05). The P90 composite flexural strength was not significantly influenced by the different activating methods, while Z250 achieved significantly higher values for the high intensity protocol when compared to the conventional one. For all light intensities, the Z250 results were higher than those for P90. P90's microhardness was statistically higher for the medium intensity group when compared to the others, whereas Z250's results had no statistical difference for the different activating protocols. For the same irradiation, Z250 presented higher values for microhardness than P90, except for the medium intensity protocol, which had no statistical difference between the different materials. The tensile strength values were not significantly influenced neither by the different light intensities, nor by the materials. The influence of the variation of light intensity depends upon the type of composite, as well as the mechanical property to be evaluated.
|
418 |
Avaliação clínica retrospectiva de restaurações diretas e indiretas com recobrimento de cúspides / A retrospective clinical evaluation of direct and indirect restorations with cuspal replacementBerwanger, Carolina dos Santos January 2016 (has links)
Introdução: A crescente demanda por restaurações estéticas possibilitou novas escolhas de tratamento para restaurar dentes posteriores com extensa destruição coronária. Os tratamentos destes dentes podem envolver restaurações diretas com resina composta ou indiretas do tipo onlays, fabricadas com cerâmica pura ou resina composta. Porém, dados clínicos sobre a longevidade de restaurações com recobrimento de cúspides comparando as técnicas direta e indireta e os materiais resina composta e cerâmica são raros. Objetivo: Realizar uma avaliação clínica retrospectiva de restaurações diretas (resina composta) e indiretas (resina composta e cerâmica) com envolvimento de cúspides utilizando o método FDI. Metodologia: Foram avaliadas 229 restaurações em 121 pacientes (37 homens e 84 mulheres) que receberam pelo menos uma restauração direta de resina composta com recobrimento de pelo menos uma cúspide ou uma onlay de cerômero ou cerâmica entre os anos de 2003 e 2016. A avaliação visual foi feita por um examinador previamente calibrado pelo coeficiente Kappa, utilizando-se os critérios do método FDI. Os dados foram analizados através do método Kaplan-Meier, da análise de regressão de Cox multivariada e do teste Kruskal-Wallis (p <0.05). Resultados: Entre as restaurações avaliadas foram detectadas 69 falhas. As restaurações obtiveram uma taxa de sucesso de 69,9%, com taxa anual de falha (AFR) de 8,0%. Restaurações diretas de resina composta apresentaram 34,1% de falha, com AFR de 9,6%. Onlays em cerômero apresentaram 27,3% de falha, com AFR de 7,1%. Onlays de cerâmica apresentaram 28,8% de falha com AFR de 7,6%. Restaurações em homens falharam mais do que em mulheres. A causa mais comum de falha foi fratura e retenção, ocorrendo em 48 casos (69,56% das falhas). Conclusão: Restaurações diretas de resina composta e indiretas de cerômero ou cerâmica demonstraram longevidade semelhante, independente do número de cúspides envolvidas. Restaurações indiretas tiveram menor índice de falha anual do que restaurações diretas, apresentando melhor desempenho na avaliação qualitativa. Pacientes mulheres apresentaram menor prevalência e menor risco de falha de restaurações do que pacientes do sexo masculino. / Introduction: The increasing demand for aesthetic restorations had enabled new treatment choices to restore posterior teeth with extensive coronary destruction. The treatments of these teeth involve direct composite restoration or indirect onlays, made with ceramic or composite. However, clinical data on the longevity of cuspal restorations comparing direct or indirect techniques and the materials are rare. Objective: To perform a retrospective clinical evaluation of direct restorations (composite resin) and indirect restorations (composite resin and ceramics) with cuspal involvement using the FDI criteria. Methodology: 229 restorations were evaluated in 121 patients (37 men and 84 women) who received at least one direct composite restoration with envolvement of at least one cusp or ceramic and composite onlays among the years 2003 and 2016. The visual evaluation was done by an examiner previous calibrated by the Kappa coefficient, using the FDI criteria. Data were analyzed by the Kaplan-Meier method, multivariated Cox regression analysis and Kruskal-Wallis test (p<0.05). Results: Among the evaluated restorations, 69 failures were detected. Restorations achieved a survival rate of 69.9%, with annual failure rate (AFR) of 8.0%. Direct composite restorations presented a 34.1% failure, with AFR of 9.6%. Composite onlays presented 27.3% of failure, with AFR of 7.1%. Ceramic onlays showed a 28.8% failure rate with AFR of 7.6%. Restorations in men have failed more than in women. The most common reason for failure was fracture of the material and retention, occuring in 48 cases (69.56% of failures). Conclusion: Direct and indirect restorations showed similar longevity, regardless of the number of cusps involved. Indirect restorations had lower annual failure rate than direct restorations, presenting better performance in the qualitative analisys. Female patients presented lower prevalence and lower risk of failure of restorations than male.
|
419 |
Avaliação quantitativa e qualitativa da rugosidade superficial de resinas compostas com nanopartículas submetidas a diferentes métodos de polimentoCosta, Catharina Simoni da January 2013 (has links)
Introdução: Existe no mercado odontológico muitos instrumentos rotatórios para serem utilizados no polimento final de uma restauração adesiva. Como são muitas as opções, e um mesmo fabricante tem mais de um tipo de instrumento rotatório para realizar a finalização da restauração, não se estabelece uma conduta única que determine qual o instrumento utilizar para resinas compostas que contenham nanopartículas. Objetivo: Avaliar, in vitro, o efeito de dois diferentes sistemas de polimento, baseados em um e multi etapas, sobre a qualidade e rugosidade da superfície de duas resinas com nanopartículas. Materiais e métodos: As amostras foram confeccionadas com resina nanoparticulada Filtek Z 350 XT (3M ESPE) e nanohíbrida Tetric N Ceran (Ivoclar Vivadent ). As amostras foram confeccionadas em moldes cilíndricos medindo 3 mm X 6 mm. Um único operador executou todos os procedimentos. Cada grupo foi composto por 20 amostras: 1) ZXT-Controle (sem polimento); 2)TNC-Controle (sem polimento); 3) ZXT+ Sof-Lex (seqüência Laranja – fina e superfina); 4) ZXT+ Optrapol; 5) TNC+ Optrapol ; 6) TNC+ Sof- Lex (seqüência Laranja – fina e superfina ). A rugosidade de superfície foi avaliada com rugosímetro (Ra), MEV e AFM. Estatística: Para análise das médias de rugosidade Ra (μm), os dados foram submetidos aos testes de normalidade de ANOVA, ao nível de significância de 5%. Uma vez verificada a distribuição normal dos resultados, estes foram submetidos à análise de variância, seguida pelo teste de Tukey com nível de significância de 5%. Resultados: As análises qualitativas e quantitativas mostraram que as resinas polidas com Optrapol apresentaram maior rugosidade superficial e o polimento com Sof-Lex não mostrou diferença estatística entre as resinas testadas. A menor rugosidade foi obtida com os grupos controle, sem diferença estatística entre as resinas. Conclusão: Optrapol promove maior rugosidade nas resinas testadas, e ZXT apresentou maior rugosidade. O polimento com Soft-Lex não mostrou diferenças estatisticamente significantes entre as resinas testadas. A rugosidade superficial das resinas foi menor com TNC, quando comparado com Optrapol. A menor rugosidade de superfície obtida foi pelo grupo controle. / Introduction: There are many tools on the market dental rotary for use in polishing of a restoration adhesive. As there are many choices, and the same manufacturer have more than one type of rotary apparatus of restoration, does not establish a single conduit to determine which tool to use composites containing nanoparticles. Objective: To evaluate, in vitro, the effect of two different polishing systems, based on a multi steps and on the quality and surface roughness of two composites nanoparticles. Materials and methods: The samples were prepared with nanofilled material resin Filtek Z 350 XT (3M ESPE) and nanohíbrid Tetric N Ceran (Ivoclar Vivadent). The samples were made in cylindrical molds measuring 3 mm X 6 mm. A single operator executed all procedures. Each group consisted of 20 samples: 1) ZXT-control (without polishing); TNC-2) control (without polishing); 3) ZXT Sof-Lex (Orange – fine and Superfine); 4) ZXT Optrapol; 5) TNC Optrapol; 6) TNC Sof-Lex (Orange – fine and Superfine). The surface roughness was assessed with porfilometry (Ra), SEM and AFM. Statistical analyses: For analysis of mean roughness Ra (um), the data were tested for normality of ANOVA, at a significance level of 5%. Once verified the normal distribution of the results, they were subjected to analysis of variance followed by Tukey's test with a significance level of 5%. Results: The qualitative and quantitative analyzes showed that resins polished with Optrapol showed higher surface roughness and polishing with Sof-Lex showed no statistical difference between the resins tested. The lowest roughness was obtained with the control group, with no statistical difference between the resins. Conclusion: Optrapol promotes greater roughness in the resins tested, and ZXT showed higher roughness. Polishing with Soft-Lex showed no statistically significant differences between the tested resins. The surface roughness of the resins with TNC was lower when compared with Optrapol. The lowest surface roughness was obtained by the control group.
|
420 |
Avaliação clínica retrospectiva de restaurações estéticas : classe III, IV e V / Retrospective clinical evaluation of esthetic restorations : class III, IV and VVieira, Rodrigo Monteiro January 2015 (has links)
O objetivo do presente estudo foi realizar uma avaliação clínica retrospectiva de restaurações diretas de resina composta de classe III, IV e V em dentes anteriores e pré-molares utilizando os métodos USPHS e FDI. Oitenta e sete pacientes foram selecionados através de uma pesquisa dos prontuários presentes no Setor de Acolhimento da Faculdade com restaurações realizadas entre 2000 a 2013 que possuíam um período mínimo em boca de 6 meses. Foram incluídos pacientes adultos de ambos os sexos que receberam tratamento com restaurações de classe III, IV ou V realizadas com as resinas compostas: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic e Opallis; realizadas com sistema adesivo convencional; em dentes vitais ou não vitais. Aqueles pacientes que possuíam higiene oral precária ou com necessidades especiais não foram incluídos no estudo. A avaliação clínica foi feita através dos métodos USPHS e FDI modificados por um examinador calibrado. A análise de sobrevivência das restaurações foi realizada através do método Kaplan-Meier e teste Log-Rank para comparação entre os grupos. A regressão de Cox multivariada e Hazard Ratio foram empregadas para verificar os fatores associados à falha das restaurações. O nível de significância foi de 5%. Foram avaliadas 272 restaurações, com um intervalo de tempo em boca de 8 meses até 13 anos (média - 4,8 anos). Foram avaliadas 120 restaurações classe III, entre elas, 15 apresentaram falhas (12,5%), com uma taxa de falha anual de 2,74%. Já para as restaurações de classe IV, realizou-se a avaliação de 80 restaurações, 38 demonstraram falhas (47,5%), como uma taxa de falha anual de 12,6%. E para as de classe V, foram analisadas 72 restaurações, sendo observada a presença de falhas em 27 delas (37,5%), com uma taxa de falha anual de 9,3%. O motivo mais comum de falha foi por fratura e/ou retenção para as três classes, ocorrendo em 73 casos. Dentes não vitais demonstraram 50% de falha em um tempo médio de 4,8 anos com uma taxa de falha anual de 13,4%; enquanto os dentes vitais apresentaram 28,1% de falha com uma taxa de falha anual de 6,6%. A regressão de Cox revelou associação entre marca comercial do compósito, classe da restauração e vitalidade pulpar com falha das restaurações. Conclui-se que restaurações de resina composta demonstraram um desempenho clínico satisfatório ao longo do tempo, apresentando sucesso em 70,6% dos casos em uma média de 4,8 anos, sendo que as de classe III apresentaram melhor desempenho clínico que classe V e classe IV e as restaurações em dentes desvitalizados apresentaram 2,37 vezes mais risco de falhas que restaurações em dentes vitais. Os principais motivos de falha para todos os tipos de restauração foi por fratura e/ou perda de retenção. Os dois métodos (USPHS e FDI) se demonstraram eficazes no processo de avaliação clínica em restaurações em dentes anteriores. / The aim of this study was to evaluate direct composite restorations Class III, IV, V in anterior teeth and premolars through the USPHS and FDI methods. Eighty-seven patients were selected through a search of the patients’ records present in the School of Dentistry. Restorations performed between 2000 to 2013 which a minimum of six months in mouth were selected. Adult patients of both sexes were included, who received treatment with restorations class III, IV or V with the follow composites: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic and Opallis; all restorations with total etch adhesive system; on vital and non-vital teeth. Patients with poor oral hygiene or special needs were not included in the study. Clinical evaluation was performed by USPHS and FDI modified methods, by one calibrated examiner. The survival of the restorations was analyzed using the Kaplan-Meier method and log-rank test to compare the groups, and multivariate Cox regression and hazard ratio were employed to identify factors associated with the failure of the restorations. The significance level was 5%. 272 restorations were evaluated with a time interval in service from 8 months to 13 years (mean 4.8 years). 120 class III restorations were evaluated, among them, 15 had failures (12.5%), with an annual failure rate of 2.74%. For the class IV type, 80 restorations were evaluated, 38 demonstrated failures (47.5%), with an annual failure rate of 12.6%. And for the class V, 72 restorations were analyzed, being observed the presence of failures in 27 of them (37.5%), with annual failure rate of 9.3% .The most common reason for failure was fracture or retention loss, for the three types of classes, occurring in 73 cases. Non-vital teeth showed 50% of failure in an average of 4.8 years, with an annual failure rate of 13.4%; while the vital teeth showed 28.1% of failure, with an annual failure rate of 6.6%. Cox regression revealed an association between brands, class type and tooth vitality with failures of the restorations. It was concluded that composite restorations showed a satisfactory clinical performance over time, with success in 70.6% of cases in a mean time of 4.8 years. Class III showed better clinical performance than class IV and V. Non-vital teeth restorations had 2.37 times the risk of failures than vital teeth. The main reasons for failure for all types of restoration was fracture and / or retention loss. Both methods (USPHS and FDI) demonstrated efficient in the process of clinical evaluation for anterior teeth.
|
Page generated in 0.0566 seconds