• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

"Viscoelasticidade em função dos modos de fotoativação de compósitos" / Viscoelasticity as a function of fotoactivation mode

Lazaro Filho, Milton 28 September 2004 (has links)
O escoamento viscoelástico pode contribuir ao alívio da tensão gerada durante a polimerização de compósitos aderidos em cavidades. O objetivo do estudo foi verificar a influência de dois modos de fotoativação contínua com diferentes intensidades (1000 mW/cm 2 e 250 mW/cm 2 ) e mesma densidade de energia final (24 J/cm 2 ) sobre propriedades viscoelásticas de dois compósitos comerciais (Filtek A110 e Herculite XRV) após a cura. Os parâmetros viscoelásticos avaliados foram: E’ (módulo de ar-mazenamento), tand (fator de perda) e as constantes reológicas t (tempo de relaxa-mento) e h (viscosidade).. Espécimes (50 x4 x 2 mm), de cada material em cada condição de fortoativação, (total de 51) foram confeccionados à temperatura ambiente e armazenados por 7 dias a 37 o C e submetidos então, a análise dinâmico-mecânica em aparelho DMA 242 (NETZSCH): varreduras de freqüência (50, 20, 10, 5, 2, 1 e 0,1 Hz) em ensaios isotérmicos (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C e Tg) em modo flexural (três pontos). Determinou-se também, a temperatura de transição vítrea (Tg). Os resultados de E’ e tand obtidos entre os 3 e os 7 minutos a cada temperatura permitiram a obtenção do módulo complexo E*. A aplicação do princípio de transposição tempo-temperatura de Williams-Landel-Ferry (TTS), resultou na curva mestra a 37 o C de E*(w). A aplicação de algoritmo de Laplace (RSI Orchestrator – Rheometrics), permitiu a obtenção da curva-mestra na mesma temperatura de E*(t). Através da aplicação do modelo matemático de Maxwell discretizado (n=10), obteve-se o espectro de relaxamento, que permitiu a obtenção de t e h de cada ma-terial em cada condição de fotoativação. Foi determinado também, em espécimes especialmente confeccionados para estas finalidades (n=3), o grau de conversão (GC) (análise de FTIR) e micro-dureza Knoop (KHN). Ambas propriedades foram analisadas antes (temperatura ambiente) e depois de tratamento térmico (aquecimento das amostras por 10 minutos a 110 o C). Os resultados do estudo permitiram concluir que: 1) Compósitos ativados com maior intensidade de luz produzem espécimes com menor t e h; 2) E’ e tand são significantemente afetados pelo aumento da intensidade da luz ativadora, diminuindo para Filtek A110 e aumentando para Hercu-lite XRV; 3) A Tg diminui com o aumento da intensidade para Filtek A110 e permanece inalterada para Herculite XRV; 4) Para Filtek A110, GC e KHN dos espécimes curados à temperatura ambiente não mudou com o aumento da intensidade, en-quanto que para Herculite XRV diminuiu; 5) GC e KHN melhoraram para Filtek A110 com o tratamento térmico adicional; para Herculite XRV, apenas KHN melhorou com o tratamento térmico, mas não o GC. / Viscoelastic flow may contribute to the stress relief generated during composites po-lymerization adhered in cavities. The aim of this study was to verify how two modes of continuous photoactivation with different intensities (1000 mW/cm 2 and 250 mW/cm 2 ) and same density of the final energy (24 J/cm 2 ) affect viscoelastic properties after cure of two commercial composites (Filtek A110 and Herculite XRV). The evaluated viscoelastic parameters were: E’ (storage modulus), tand (loss factor) and rheologic constraints t (relaxation time) and h (viscosity). Specimens (50 x4 x 2 mm), of each material at each photoactivation mode (totaled 51) were built at room tem-perature and have been stored for 7 days at 37 o C to undergo the dynamic-mechanical analysis in DMA 242 (Netzsch) equipment. Frequency sweep was made (50, 20, 10, 5, 2, 1 and 0,1 Hz) in each of the isothermic testing (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C and Tg) in flexural test (3 points). It was also determined glass transition temperature (Tg). The results of E’ and tand obtained between 3 and 7 min-utes at each temperature allowed to obtain complex modulus E*. The application of time-temperature switch principle of Williams-Landel-Ferry (TTS) ended up in master-curve of E*(w) at 37 o C. The use of the Laplace algorithm (RSI Orchestrator – Rheometrics) allowed to obtain the master curve (at same temperature) of E*(t). By means of the using of discretized Maxwell’s mathematical model (n=10), relaxation spectrum was obtained, which resulted in t and h of each of the materials in each of the photoactivation conditions. Degree of conversion (DC) (FTIR analysis) and Knoop microhardness (KHN) were also determined in specially made specimens for these purposes (n=3). Both properties were analyzed before (room temperature) and after thermal treatment (heating of the specimens for 10 minutes at 110 o C). The results of the study allowed to conclude that: 1) Composites activated with higher intensity yield lower t and h specimens; 2) E’ and tand are meaningfully affected by the increase of the activating light intensity, decreasing for Filtek A110 and increasing for Herculite XRV; 3) Tg decreases with the intensity increase for Filtek A110 and remains un-changed for Herculite XRV; 4) For Filtek A110, DC and KHN of the cured specimens at room temperature, remained unchanged with the intensity increase, while for Her-culite XRV they decreased; 5) DC and KHN raised for Filtek A110 with additional thermal treatment – for Herculite XRV, only KHN improved with thermal treatment, but there were no changes for DC.
482

Influência do sistema fotoiniciador nas propriedades fisicoquímicas de resinas experimentais / Influence of the photoinitiator system on physical-chemical properties of experimental resins

Furuse, Adilson Yoshio 19 May 2009 (has links)
O objetivo deste trabalho foi avaliar a influência de diferentes aminas terciárias no grau de conversão, na contração de polimerização, na taxa de contração, na microdureza Knoop, na estabilidade de cor e na transmitância de luz de resinas experimentais, contendo, em peso, BisGMA e TEGDMA (3:1), 0,25% de canforquinona (CQ) e 1% de amina (DMAEMA, CEMA, DMPT, DEPT ou DABE). A influência de diferentes protocolos de fotoativação também foi investigada. O grau de conversão foi avaliado através de FTIR-ATR e a contração pelo método do disco aderido. A partir da diferenciação numérica dos dados de contração em relação ao tempo, obteve-se a taxa de contração de polimerização. A estabilidade de cor e a transmitância foram avaliadas em diferentes períodos de envelhecimento artificial. Os resultados foram avaliados pelos testes de ANOVA, Tukey e T3 de Dunnett (&#945; = 0,05). As propriedades estudadas variaram em função da amina. O grau de conversão e a contração de polimerização variaram na sequência: CQ < DEPT < DMPT &#8804; CEMA &#8776; DABE < DMAEMA. O grau de conversão e a contração também foram influenciados pelo protocolo de fotoativação, sendo observadas correlações positivas entre o grau de conversão e a contração e entre o grau de conversão e a taxa de contração. A cor variou na sequência: DMAEMA < DEPT < DMPT < CEMA < DABE. A transmitância variou na sequência: DEPT &#8776; DABE < DABE &#8776; DMPT &#8776; CEMA < DMPT &#8776; CEMA &#8776; DMAEMA, sendo mais evidente para o comprimento de onda de 400nm. Não foram observadas correlações entre o grau de conversão e as propriedades ópticas. A resina contendo DMAEMA apresentou maior grau de conversão, contração, taxa de contração e dureza, além de melhor estabilidade nas propriedades ópticas. / The aim of this work was to evaluate de influence of different tertiary amines on degree of conversion (DC), shrinkage-strain, shrinkage-strain-rate, Knoop microhardness, and colour and transmittance stabilities of experimental resins containing BisGMA / TEGDMA (3:1 wt), 0,25wt% camphorquinone, 1wt% amine (DMAEMA, CEMA, DMPT, or DABE). Different light-curing protocols were also evaluated. DC was evaluated with FTIR-ATR and shrinkage-strain with the bonded-disc method. Shrinkage-strain-rate data were obtained from numerical differentiation of shrinkage-strain data with respect to time. Colour stability and transmittance were evaluated during different periods of artificial aging, according to ISO 7491:2000. Results were evaluated with ANOVA, Tukey and Dunnetts T3 tests (&#945; = 0.05). The studied properties varied according to amines. DC and shrinkage-strain were maximum at the sequence: CQ < DEPT < DMPT &#8804; CEMA &#8776; DABE < DMAEMA. Both DC and shrinkage were also influenced by the curing protocol, with positive correlations between DC and shrinkage-strain and DC and shrinkage-strain-rate. Colour varied in the sequence: DMAEMA < DEPT < DMPT < CEMA < DABE. Transmittance varied in the sequence: DEPT &#8776; DABE < DABE &#8776; DMPT &#8776; CEMA < DMPT &#8776; CEMA &#8776; DMAEMA, being more evident at the wavelength of 400nm. No correlations between DC and optical properties were observed. The resin containing DMAEMA showed higher DC, shrinkage-strain, shrinkage-strain-rate and microhardness, in addition with better optical properties.
483

Efeito de retenções adicionais na microinfiltração e formação de microfendas na margem gengival de restaurações de classe II extensas, feitas com resina composta: avaliação antes e após ciclagem mecânica / Effect of additional retention in microleakage and gap formation in gingival margin of class II resin restorations: evaluation before and after mechanical cycling

Ishikiriama, Sérgio Kiyoshi 11 October 2006 (has links)
Este estudo laboratorial comparou a microinfiltração marginal e formação de microfendas em restaurações de classe II extensas, feitas com resina composta com margens situadas em dentina/cemento, utilizando diferentes tipos de retenções adicionais na caixa proximal. Cavidades padronizadas MOD extensas foram confeccionadas em 40 terceiros molares humanos, os quais foram divididos em 4 grupos de acordo com a retenção adicional confeccionada na caixa proximal: (G1) sem retenção adicional - controle; (G2) canaletas verticais nas paredes vestibular e lingual; (G3) orifícios na parede gengival e (G4) canaleta horizontal na parede gengival. Todos os grupos foram restaurados pela técnica incremental, com sistema adesivo (Prime Bond NT - Dentsply) e resina composta híbrida (QuiXfil - Dentsply). Todos os dentes restaurados foram imersos em corante com aplicação simultânea de cargas contínuas (forças variando entre 1kg e 17kg). Moldagens da margem gengival restaurada foram realizadas antes e após a ciclagem mecânica e réplicas de resina epóxica foram obtidas e analisadas em microscópio eletrônica de varredura para avaliação das microfendas marginais. Após as moldagens, todos os dentes foram seccionados para análise da microinfiltração marginal. Todas as micrografias da margem gengival e imagens dos cortes seccionados foram analisados quantitativamente no programa Image Tools (UTHSCSA). Os valores para microinfiltração foram submetidos a análise de variância e teste de Tukey (p< ou = 0,05). As extensões das fendas antes e após a ciclagem mecânica foram comparadas pelo teste \'t\'\' de Student. Também foi realizada uma análise de correlação entre a extensão das microfendas e microinfiltração marginal (teste de correlação de Pearson). Todos os grupos com retenção adicional (G2=11,59, G3=7,11 e G4=1,57) apresentaram microfendas significantemente menos extensas que o grupo controle sem retenção (G1=42,43) (p< ou = 0.05). Resultados similares foram obtidos para a análise de microinfiltração (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), com diferenças significantes entre todos os grupos (p< ou = 0,05). Todos os grupos apresentaram aumento na extensão das fendas após a aplicação de cargas contínuas, com exceção do grupo da canaleta horizontal (grupo 4). Este tipo de retenção adicional apresentou os melhores resultados em ambos os parâmetros. Os resultados mostraram uma tendência a correlação entre os dois parâmetros estudados. Segundo os resultados, as retenções adicionais podem melhorar a adaptação marginal e minimizar a microinfiltração em restaurações de classe II extensas, feitas com resina composta. / This in vitro study compared marginal leakage and gap formation in resin composite class II cavities with gingival margin in cementum, using 3 different additional retention in proximal box. Standardized large MOD cavities, with gingival margins in cementum, were prepared in forty extracted human molars and divided into 4 groups according to the retention in proximal box: (G1) no retention; (G2) vertical grooves in buccal and lingual walls; (G3) pins in gingival wall; and (G4) horizontal grooves in gingival wall. All groups were restored with the incremental technique, using hybrid resin composite (QuiXfil - Dentsply) and bonding agent (Prime Bond NT - Dentsply). All restored teeth were immersed in dye with simultaneous mechanical loading (alternated loading between 1kg and 17kg). Impressions of gingival margins were made before and after mechanical loading and epoxic resin replicas were evaluated in scanning electron microscope for gap formation. After the impressions, all teeth were seccioned for microleakage evaluation. All SEM photomicrographs and seccioned teeth images were analysed with Image Tools (UTHSCSA) software for a quantitative analysis of both parameters. Microleakage data were evaluated by ANOVA and Tukey\'s test. Gap extension before and after mechanical loading were evaluated by Student\'s t test. A correlation analysis was made between gap extension and microleakage (Pearson\'s correlation test). All groups with additional retention (G2=11,59, G3=7,11 e G4=1,57) showed fewer gap formation than control group (G1=42,43) (p< or = 0.05). Similar results were found for microleakage tests (G1= 82,84; G2=64,73; G3=45,42; G4=3,09), with significant differences between all groups (p< or = 0,05). All groups presented an increase in gap extension after loading, with exception to group with gingival retention grooves (G4). This group (G4) showed the best results in both parameters (p< or = 0.05).The results showed a tendency for correlation between the parameters. According the results, additional retention may improve marginal adaptation and minimize leakage in large class II resin composite restorations.
484

Caracterização térmica, grau de conversão, resistência à flexão e dureza de compósitos comerciais tratados termicamente / Thermal characterization, degree of conversion, flexural strength and Knoop hardness of heat treated commercial composites

Miyazaki, Caroline Lumi 03 August 2010 (has links)
Visando otimizar as propriedades químicas e mecânicas de compósitos de uso direto aplicados na forma indireta, associados a tratamentos térmicos experimentais (TT), torna-se necessária uma caracterização térmica que permita a determinação de uma temperatura de TT segura (abaixo da temperatura de início de perda de massa). Assim, a primeira etapa deste estudo consistiu em caracterizar termicamente dez compósitos comerciais (Z100, Filtek Z250, Z350 e Supreme XT- 3M ESPE, Esthet-X e TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV e Point 4 - Kerr), fotoativados pelo método contínuo (C) e pulse-delay (PD) (20 J.cm-2), por termogravimetria (TG) (n=1) e calorimetria exploratória diferencial (DSC) (n=3). Foram escolhidas duas temperaturas de TT: 100 e 170°C, aplicadas por 10 min, 24h após a fotoativação. A partir disto, avaliaram-se: 1) o grau de conversão (GC), por espectroscopia FT-Raman (n=3); 2) a resistência à flexão em três pontos (RF) (n=10); e 3) a dureza Knoop (KHN) para as faces topo e base (n=3) de quatro destes compósitos (Filtek Z250 e Supreme XT, Esthet-X e Point 4), após diferentes condições: imediatamente, 1h, 6h e 24h após a fotoativação e 24h após fotoativação seguida de TT a 100 ou 170°C. Os dados obtidos foram submetidos à análise de variância e ao teste de Tukey (nível de significância de 5%). Quanto ao GC (%), houve significância estatística para o fator material (p=0,000): Point 4 (68,42) > Z250 (63,05) = Esthet-X (61,69) > Supreme (54,27); condição (p=0,000): TT170 (73,20) = TT100 (73,58) > 24h (62,60) = 6h (60,18) > 1h (55,10) = imediato (53,66); e ativação (p=0,006): C (62,97) > PD (60,75). Também foram significantes as interações material × condição (p=0,007) e material × condição × ativação (p=0,013). Para a RF (MPa), foram encontradas significâncias estatísticas para os fatores material (p=0,000): Z250 (165,48) > Supreme (153,96) > Point 4 (131,30) = Esthet-X (128,06); e condição (p=0,000): TT170 (194,56) > TT100 (182,91) > 24h (150,88) > 6h (131,79) > 1h (111,77) > imediato (96,30); assim como para as interações: ativação × condição (p=0,000), material × condição (p=0,000) e material × ativação × condição (p=0,000). Para a dureza, foram encontradas significâncias estatísticas para os fatores: materialativação (p=0,000): Supreme C (82,46) > Supreme PD (80,29) = Z250 C (77,46) > Z250 PD (74,30) > Esthet-X C (69,17) > Esthet-X PD (65,67) > Point 4 C (57,21) = Point 4 PD (56,71); condição (p=0,000): TT170 (81,35) > TT100 (73,72) > 24h (70,36) > 6h (67,92) > 1h (64,99) > imediato (64,12) e face (p=0,000): topo (71,40) > base (69,40); assim como para as interações: material-ativação × face (p=0,011), material-ativação × condição (p=0,000) e face × condição (p=0,000). A partir dos resultados obtidos, pôde-se concluir que os TTs experimentais propostos foram capazes de aumentar as propriedades estudadas, sendo, de maneira geral, os resultados obtidos com 170°C melhores do que os com 100°C, e ambos melhores do que as demais condições. / Aiming to optimize chemical and mechanical properties of direct composites applied in an indirect way, with an association to experimental heat treatments (TT), it is necessary a thermal characterization, in a way to determine a safe temperature for the TT (below the significant mass loss temperature). Thus, the first step of this study was to perform the thermal characterization of ten commercial composites (Z100, Filtek Z250, Z350 and Supreme XT 3M-ESPE, Esthet-X and TPH Spectrum Dentsply, Charisma Heraeus Kulzer, Tetric Ceram Ivoclar Vivadent, Herculite XRV and Point 4 - Kerr) photoactivated by continuous (C) and pulse-delay (PD) methods (20 J.cm-2), by thermogravimetry (TG) (n=1) and differential scanning calorimetry (DSC) (n=3). After that, two temperatures were chosen for the TT: 100 and 170°C, which were applied for 10 min, 24h after photoactivation. Thus, some properties were evaluated for four composites (Filtek Z250 and Supreme XT, Esthet- X and Point 4): 1) degree of conversion (GC) by FT-Raman spectroscopy (n=3); 2) three-point bending test (RF) (n=10); and 3) Knoop hardness (KHN) for top and bottom surfaces (n=3). The conditions were: immediately, 1h, 6h and 24h after photoactivation and 24h after photoactivation followed by TT at 100 or 170°C. Data were analyzed by ANOVA and Tukeys test (level of significance of 5%). In relation to GC (%), there were statistical significance for the factors material (p=0.000): Point 4 (68.42) > Z250 (63.05) = Esthet-X (61.69) > Supreme (54.27); condition (p=0.000): TT170 (73.20) = TT100 (73.58) > 24h (62.60) = 6h (60.18) > 1h (55.10) = immediately (53.66); and activation (p=0.006): C (62.97) > PD (60.75); and for the interactions: material × condition (p=0.007) and material × condition × activation (p=0.013). For RF (MPa), statistical significance were found for the factors material (p=0.000): Z250 (165.48) > Supreme (153.96) > Point 4 (131.30) = Esthet-X (128.06); and condition (p=0.000): TT170 (194.56) > TT100 (182.91) > 24h (150.88) > 6h (131.79) > 1h (111.77) > immediately (96.30); and also for the interactions: activation × condition (p=0.000), material × condition (p=0.000) and material × activation × condition (p=0.000). For KHN, statistical significance were found for the factors material-activation (p=0.000): Supreme C (82.46) > Supreme PD (80.29) = Z250 C (77.46) > Z250 PD (74.30) > Esthet-X C (69.17) > Esthet-X PD (65.67) > Point 4 C (57.21) = Point 4 PD (56.71); condition (p=0.000): TT170 (81.35) > TT100 (73.72) > 24h (70.36) > 6h (67.92) > 1h (64.99) > immediately (64.12), and face (p=0.000): top (71.40) > bottom (69.40); as for the interactions: material-activation × face (p=0.011), material-activation × condition (p=0.000) and face × condition (p=0.000). By the results, it could be concluded that both proposed experimental TTs were capable of increasing the studied properties, with, in a general way, 170°C generating better mechanical properties than 100°C, and both better than the other conditions.
485

Influência de aditivos nas propriedades de comonômeros, copolímeros e compósitos a base de Bis-GMA, diluído com TEGDMA ou análogos sintetizados do Bis-GMA (CH3Bis-GMA e CF3Bis-GMA) / Influence of additives on the properties of comonomers, copolymers and composites based on Bis-GMA, diluted with TEGDMA or the synthesized Bis-GMA analogs (CH3Bis-GMA and CF3Bis-GMA)

Prakki, Anuradha 16 July 2007 (has links)
O objetivo deste estudo foi avaliar a influência de dois aditivos, propionaldehyde (propanal aldeído) e 2,3-butanedione (diquetona diacetil), nas propriedades de comonômeros, copolímeros e resinas compostas à base de Bis-GMA, quando diluído com TEGDMA, Bis-GMA propoxilado (CH3Bis-GMA) e Bis-GMA propoxilado fluorinado (CF3Bis-GMA). Comonômeros, copolímeros e compósitos experimentais foram preparados combinando Bis-GMA com TEGDMA, CH3Bis-GMA, CF3Bis-GMA e, aldeído (24 e/ou 32 mol%) e diquetona (24 e/ou 32 mol%). No caso dos compósitos, partículas híbridas silanizadas (bário aluminosilicato; 60 peso%) foram adicionadas aos comonômeros. Para a fotopolimerização, adicionou-se canforoquinona (0,2 peso%) e N,N-dimetil-p-toluidina (0,2 peso%). Os comonômeros e copolímeros experimentais tiveram as seguintes propriedades avaliadas: viscosidade, contração de polimerização, grau de conversão, ângulo de contato (em esmalte, dentina e vidro), temperatura de transição vítrea (DSC e equação de Fox), microdureza, alteração de rugosidade superficial e desgaste por abrasão. Os compósitos experimentais, tiveram avaliadas as seguintes propriedades: resistência flexural, módulo de elasticidade, tração diametral, módulo de resiliência, microdureza, alteração de rugosidade superficial e desgaste por abrasão. Os sistemas Bis-GMA/TEGDMA e Bis-GMA/CH3Bis-GMA tiveram suas propriedades significantemente alteradas pela incorporação de aditivos (propanal ou diquetona). Os aditivos (propanal/diquetona) não influenciaram de forma significante as propriedades do sistema Bis-GMA/CF3Bis-GMA. O efeito dos aditivos nas propriedades dos materiais analisados relaciona-se à sua abilidade em aumentar o grau de conversão de alguns sistemas resinosos / The purpose of this study was to evaluate the effect of two additives, propionaldehyde (aldehyde) and 2,3-butanedione (diketone), on the properties of Bis-GMA based comonomer, copolymer and composites when diluted with TEGDMA, propoxylated Bis- GMA (CH3Bis-GMA) and propoxylated fluorinated Bis-GMA (CF3Bis-GMA). Experimental comonomer/copolymer/composites were prepared combining Bis-GMA and TEGDMA, CH3Bis-GMA, CF3Bis-GMA, with aldehyde (24 and/or 32 mol%) and diketone (24 and/or 32 mol%). For composites, hybrid treated filler (barium aluminosilicate glass; 60 wt%) was added to monomer mixtures. Photopolymerization was effected by using camphorquinone (0.2 wt%) and N,N-dimethyl-p-toluidine (0.2 wt%). Experimental comonomer/copolymers viscosity, polymerization shrinkage, degree of conversion, contact angle (enamel, dentin and glass surfaces), glass transition temperature (DSC and Fox equation), microhardness, surface roughness changes and wear were evaluated. Experimental composites, flexural strength, modulus of elasticity, diametral tensile strength, modulus of resilience, microhardness, surface roughness changes and wear were also assessed. Bis-GMA/TEGDMA and Bis- GMA/CH3Bis-GMA systems had properties significantly influenced by incorporation of additives (either propanal or diketone). Additives (propanal/diketone) did not significantly influence on Bis-GMA/CF3Bis-GMA system properties. The effect of additives on the evaluated material properties is mainly attributed to their ability in improving some resin systems degree of conversion
486

Avaliação clínica e laboratorial de resina composta em função da fotoativação com diferentes fontes de luz e densidades de potência / Clinical and laboratorial evaluation of resin composite light-cured with different curing units and power densities

Benetti, Ana Raquel 27 July 2007 (has links)
O objetivo deste estudo foi avaliar o desempenho clínico e laboratorial de uma resina composta, considerando diferentes fontes de luz e densidades de potência, mantendo-se padronizada a densidade total de energia. O grau de conversão da resina composta foi determinado através de espectroscopia por transformada de Fourier. O grau de amolecimento em etanol foi obtido pela determinação da dureza Wallace, antes e após o armazenamento da resina composta em etanol a 75%. O desgaste foi mensurado por dois métodos: o teste da ACTA e o teste de escovação simulada. Paralelamente, investigou-se o desempenho clínico de restaurações de resina composta em dentes posteriores, submetidas aos mesmos protocolos de fotoativação. Restaurações de classe I de resina composta foram confeccionadas e fotoativadas por lâmpada de quartzo-tungstênio ou diodo emissor de luz a 300 mW/cm2, durante 40 segundos, ou a 600 mW/cm2, durante 20 segundos. As restaurações foram avaliadas, imediatamente e após 6 e 12 meses, por dois examinadores calibrados, de acordo com os critérios modificados de Ryge. Os dados laboratoriais foram submetidos à análise de variância a dois critérios e teste de comparações múltiplas de Newman-Keuls, ou ao teste t-pareado. Os dados clínicos foram analisados pelos testes Kappa, Fisher e McNemar (\'alfa\' = 0,05). Não foram constatadas diferenças significantes quanto aos diferentes protocolos no grau de conversão, no grau de amolecimento em etanol e no desgaste produzido pelo método da ACTA (p > 0,05). Para o teste de desgaste por escovação simulada, a fotoativação com diodos emissores de luz a 300 mW/cm2, durante 40 segundos, resultou em maior desgaste que os demais protocolos testados (p < 0,05). Adicionalmente, não foram observadas diferenças significantes quanto aos diferentes protocolos de fotoativação no desempenho clínico das restaurações, ao final de um ano de avaliação (p > 0,05) / The aim of this study was to evaluate the clinical and laboratorial performance of a resin composite light-cured with different light-curing units and power densities, at a standard energy density level. Degree of conversion of the resin composite was determined by Fourier transformed infrared spectroscopy. The degree of softening of the resin composite in ethanol was obtained by Wallace hardness measurements before and after storage in a 75% ethanol solution. Wear of the resin composite was acquired by two methods: ACTA wear and toothbrush abrasion. Additionally, the clinical performance of resin composite restorations submitted to the same light-curing protocols was followed up. Class I resin composite restorations were light-cured using either halogen lamp or light emitting diode at 300 mW/cm2 during 40 seconds or 600 mW/cm2 during 20 seconds. Restorations were evaluated immediately and after 6 and 12 months by two calibrated dentists, according to the modified Ryge criteria. The laboratorial data were submitted to two-way analysis of variance and Newman- Keuls multiple comparison test, or t-test. Clinical data were analyzed by Kappa, Fisher and McNemar tests (\'alpha\' = 0.05). No significant differences were observed for the different light-curing protocols in the degree of conversion, degree of softening in ethanol, and wear produced by the ACTA method (p > 0.05). For the toothbrush abrasion test, irradiation with the light emitting diode unit for 40 seconds at 300 mW/cm2 resulted in higher wear than the other light-curing protocols (p < 0.05). No significant differences were detected at the one-year clinical follow-up of the resin composite restorations submitted to the various light-curing protocols investigated in this study (p > 0.05).
487

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Morais, Renata Costa de 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
488

Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strength

Renata Costa de Morais 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
489

Influência do conteúdo inorgânico e da composição da matriz resinosa no desenvolvimento de tensões de polimerização em compósitos experimentais / Influence of inorganic content and resin matrix composition on polymerization stress development

Gonçalves, Flavia 11 May 2010 (has links)
Objetivo: avaliar a relação de dependência da tensão de polimerização (TP), grau de conversão (GC), taxa máxima de reação de polimerização (Rpmax), contração volumétrica (CV), módulo de elasticidade (E) e tangente de delta (tan) com o conteúdo inorgânico e proporção de BisGMA:TEGDMA e verificar as possíveis relações de dependência entre a TP e as demais variáveis-resposta. Material e métodos: Foram preparadas vinte formulações, com concentrações de carga de 40, 50, 60 ou 70 % em peso de vidro de bário e proporções molares de BisGMA:TEGDMA de 3:7, 4:6, 5:5, 6:4 ou 7:3. TP (n=7) foi determinada pela inserção do compósito entre bastões de acrílico fixados às garras de uma máquina universal de ensaios e dividindo-se a máxima força de contração registrada pela secção transversal dos bastões. GC e Rpmax foram determinados por espectroscopia no infra-vermelho próximo (n=5). CV foi mensurada em dilatômetro de mercúrio (n=3). E foi obtido através do teste de flexão em três pontos (n=10). Tan foi determinada por nanoidentação dinâmica (n=3). Foram realizadas análises de regressão para avaliar a influência da fração inorgânica e da proporção monomérica nas variáveis estudadas e para avaliar o efeito das variáveis-resposta na determinação da TP. Resultados: Todas as variáveis se mostraram dependentes da concentração inorgânica e conteúdo monomérico. TP, GC e Rpmax foram mais influenciados pela matriz, enquanto que CV, E e tan apresentaram maior efeito da concentração de carga. TP mostrou-se dependente dos fatores CV e GC. Conclusões: a formulação de compósitos com baixa TP deve observar criteriosamente a fração inorgânica e o conteúdo monomérico, sendo o principal desafio encontrar formulações com baixa CV, uma vez que os demais fatores demonstraram não ter influência significativa e o GC do material não deve ser sacrificado com o propósito de reduzir a TP. / Objective: To evaluate the dependence relationship of polymerization stress (PS), degree of conversion (DC), maximum polymerization rate (Rpmax), volumetric shrinkage (VS), elastic modulus (E) and loss tangent (tan) with the inorganic content and BisGMA:TEGDMA ratio and verify possible relationship among PS and the others variables. Materials and Methods: twenty resin composites were studied, having barium glass concentration of 40, 50, 60 or 70 wt% and BisGMA:TEGDMA molar ratio of 3:7, 4:6, 5:5, 6:4 or 7:3. PS (n=7) was determined inserting the composite between acrylic rods fixed to clamps of an universal test machine and dividing the maximum load recorded by the rods cross-sectional area. DC and Rpmax were determined by near infrared spectroscopy in real time (n=5). VS was measured by mercury dilatometer (n=3). E was obtained by three-point bending test (n=10). Tan was determined by dynamic nanoindentation (n=3). Regression analyses were performed to evaluate the relationship of inorganic content and monomeric ratio on studied variables and to evaluate the effect of the variables on the polymerization stress development. Results: All variables showed dependence on inorganic concentration and monomeric content. PS, DC and Rpmax were more affected by resin matrix whereas VS, E and Tan were more strongly influenced by filler fraction. PS was dependent on both volumetric shrinkage and degree of conversion. Conclusions: in order to obtain composites formulations which provide low polymerization, the inorganic concentration and monomeric contend have to be carefully observed. The main challenge is to design formulations with low VS since the others factors apparently do not have significance and PS should not come at the expense of DC.
490

Efeito do armazenamento em água na resistencia de União de diferenets abordagens de adesão a dentina / Effects of water storage on resin-dentin bond strengths formed by different bonding approaches

Martins, Gislaine Cristine 21 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 Gislaine Cristine Martins.pdf: 4206631 bytes, checksum: c89ea8320c5c7cd1115382f7f0e02b50 (MD5) Previous issue date: 2008-02-21 / The purpose of this study was to evaluate the effects of water storage on resindentin bond strengths [μTBS] formed by different adhesive bonding approaches. A flat superficial dentin surface the 24 human third molars were exposed and polished to create a standardized smear layer. The teeth were randomly distributed into four different: total-etch 3 step (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP), and total-etch 2 step (Adper™ Single Bond 2, 3M ESPE - SB); self-etch 2 step (AdheSE, Ivoclar/Vivadent - AD); and self-etch 1 step (Adper™ Prompt™ LPop ™, 3M ESPE - LP). Following the adhesive application (n=6), resin composite crowns were incrementally placed (Filtek™ Supreme XT - 3M ESPE) in order to obtain bonded sticks, with a cross-sectioned area of about 0,8 mm2. The bonded sticks were randomly divided and assigned to be tested immediately [IM] (n=30) or after 6 months of water storage [6M](n=30). Two-way ANOVA and Tukey’s test showed that none of the adhesives showed degradation after 6 months, except SB, which was the one that achieved the highest μTBS either in the immediate time (49.13 MPa) and after 6 months (40.27 MPa). LP showed the lowest μTBS in both periods of evaluation (18.35 and 18.34 MPa). AD and SBMP showed intermediate performance. But the SB showed lower μTBS significantly after storage anyway showed high results. Conclusion: Although a significant degradation was only observed for SB, this was the adhesive that showed the highest μTBS after 6M of water storage. It seems that the microtensile test is not sensitive to detect degradation for adhesives with low immediate μTBS. / Este estudo objetivou avaliar o efeito do armazenamento em água na resistência de união [μTBS] de diferentes abordagens de adesão à dentina. As superfícies oclusais de 24 terceiros molares hígidos foram cortadas, planificadas e, a smear layer padronizada. Os dentes foram divididos aleatoriamente em 4 grupos de acordo com a abordagem de união, ou seja, convencionais, de 3 passos (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP) e, de 2 passos (Adper™ Single Bond 2, 3M ESPE -SB); autocondicionantes, de 2 passos (AdheSE, Ivoclar/Vivadent - AD) e, de 1 passo (Adper™ Prompt™ L-Pop™, 3M ESPE - LP). Após o procedimento adesivo (n=6) os dentes foram restaurados pela técnica incremental com resina composta Filtek™ Supreme XT (3M ESPE). Obteve-se 240 espécimes em forma de palitos com área aproximada de 0,8 mm2. Dos espécimes obtidos para cada grupo (n=60), metade foi submetido ao teste de resistência de união imediato [IM] (n=30) e, a outra metade foi armazenada em água para realização do teste após 6 meses de armazenamento [6M](n=30). A ANOVA 2 fatores e o pós-teste de Tukey mostraram que não ocorreu degradação após 6M, exceto para o SB, ainda assim, a maior média da resistência de união IM e 6M foi do SB (49.13 e 40.27 MPa). O LP mostrou as menores médias nos dois períodos de avaliação (18.35 e 18.34 MPa). O AD e o SBMP apresentaram desempenho intermediário. Entretanto, o SB apresentou redução significativa da resistência de união após 6M, apesar disso, obteve os melhores resultados. Concluiu-se que embora ocorreu uma degradação significativa para o SB, este sistema foi o que apresentou maior μTBS após 6 meses de armazenamento em água. O teste de microtração não foi sensível para detectar a degradação dos sistemas adesivos com valores mais baixos de μTBS.

Page generated in 0.0922 seconds