• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 604
  • 39
  • 39
  • 39
  • 39
  • 23
  • 11
  • 11
  • 10
  • 10
  • 5
  • 5
  • 2
  • 1
  • Tagged with
  • 625
  • 625
  • 321
  • 252
  • 178
  • 146
  • 142
  • 142
  • 115
  • 110
  • 74
  • 73
  • 73
  • 61
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
521

Avaliações clínica e clínica/fotográfica de restaurações adesivas, realizadas em lesões cervicais não cariosas : efeitos dos materiais restauradores, tipos e tempos de avaliação /

Oliveira, Fernanda Garcia de. January 2010 (has links)
Resumo: O objetivo desse trabalho foi avaliar através das análises clínica e clínica/fotográfica o comportamento de 124 restaurações de lesões cervicais não cariosas, realizadas com uma resina composta ou com um ionômero de vidro modificado por resina, nos períodos de 6 e 12 meses após suas realizações. Foram formados 3 grupos de estudo, de acordo com os materiais e técnicas empregadas. Previamente à aplicação dos materiais adesivos, todos os dentes receberam o condicionamento com ácido fosfórico a 37% em esmalte e dentina. Após, os dentes pertencentes ao grupo I receberam o sistema adesivo convencional Scotchbond Multi Uso, seguido pela resina composta Filtek Z350; os do grupo II apenas o material ionomérico modificado por resina Fuji II L.C., enquanto que os do grupo III foram restaurados com o mesmo material ionomérico, entretanto, previamente à sua inserção, receberam a aplicação de duas camadas do primer do sistema adesivo ScotchBond Multi Uso. Após o acabamento e polimento, as restaurações foram fotografadas, bem como aos 6 e 12 meses após suas realizações. Os dentes foram avaliados por 2 examinadores, quanto aos fatores retenção, adaptação marginal, descoloração marginal, alteração de cor, presença de lesão de cárie marginal, forma anatômica e sensibilidade na análise clínica; e na análise clínica/fotográfica quanto aos fatores retenção, descoloração marginal, localização da gengiva marginal, alteração de cor e forma anatômica da restauração. Os resultados foram submetidos ao teste de Kappa observando um grau de concordância acima de 80% entre os examinadores. A aplicação do Teste de Kruskal-Wallis não apontou diferença estatisticamente significante, na análise clínica, para as variáveis forma anatômica, descoloração marginal, alteração de cor, lesão de cárie, adaptação... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the performance of 124 restorations of non-carious cervical lesion through clinical and clinical/photographic analyses. The restorations were made in composite resin or resin-modified glass ionomer and evaluated after 6 and 12 months. Three groups were obtained according to the materials and techniques. Previously to the application of the adhesive materials, all teeth were submitted to acid etching with 37% phosphoric acid in enamel and dentine. Then, the teeth of group I received the conventional adhesive system Scotchbond Multi-Purpose followed by the composite resin Filtek Z350; the teeth of group II received only the resin-modified ionomeric material Fuji II L.C.; and the teeth of group III were restored with the same ionomeric material after application of two layers of the primer of the adhesive system Scotchbond Multi-Purpose. The restorations were photographed immediately after this procedure and after 6 and 12 months. The teeth were evaluated by 2 examiners regarding retention, marginal fit, marginal discoloration, color alteration, presence of marginal caries and sensitivity during the clinical evaluation. The clinical/photographic analysis evaluated retention, marginal discoloration, localization of the marginal gingiva, color alteration and anatomy of the restoration. The results were submitted to the Kappa test that revealed degree of agreement above 80% between the examiners. The Kruskal-Wallis test showed no statistically significant difference in the clinical analysis for anatomy, marginal discoloration, color alteration, caries, marginal fit and sensitivity among the three groups for each period of evaluation. However, there was statistically significant difference for retention at the 12-month follow-up considering that the group III was superior in comparison to the group II. The... (Complete abstract, click electronic address below) / Orientador: Renato Herman Sundfeld / Coorientador: Eduardo Passos Rocha / Banca: Marcelo Giannini / Banca: Rodrigo Sversut de Alexandre / Mestre
522

Influência da temperatura sobre a microdureza de uma resina composta fotoativada com luz halógena e Leds /

Cáceres Benítez, Pablino. January 2004 (has links)
Resumo: O objetivo desta pesquisa foi avaliar a influência de várias temperaturas sobre os valores de microdureza de topo e base de uma resina composta fotopolimerizável comercialmente disponível, variando o tipo de fonte de luz (LEDs e lâmpada halógena). As temperaturas testadas foram 25, 35, 45, 55, 65, 80, 90 e 100º C. A resina composta utilizada foi a Z100 (3M). Com o auxílio de uma matriz metálica foram confeccionados 3 corpos-de-prova de 2 mm de espessura e 9,8 mm de diâmetro para cada temperatura. Os corpos-de-prova foram polimerizadas LEDs (60 s) ou lâmpada halógena (40 s) enquanto eram submetidas às diferentes temperaturas, após a polimerização as amostras foram armazenadas a seco, em estufa a 37º C. Após 24 horas as amostras foram submetidas ao teste de microdureza Vickers no topo e na base. Baseados nos resultados conclui-se que com a elevação da temperatura aumentou o valor da dureza Vickers com correlação linear positiva e com ambos aparelhos; o valor da dureza de topo foi sempre superior à dureza de base independentemente da fonte de luz ou temperaturas empregadas; o aparelho de luz halógena só se mostrou superior à fonte de LEDs na região de base dos corpos-de-prova. / Abstract: The aim of this research was to evaluate the influence of several temperatures on the microhardness values of top and base of a light curing composites resin commercially available, varying the type of light source (LEDs and halogen lamp). The tested temperatures were 25, 35, 45, 55, 65, 80, 90 and 100º C. The composite resin used was Z100 (3M). With the aid of a metallic mould were made three samples of 2 mm of thickness and 9,8 m diameter for each temperature. The samples were light cure while they where submitted to the different temperatures with LEDs (60 s) and halogen lamp (40 s), after the polymerization the samples were dry stored in a stove at 37º C. After 24 hours, the samples were submitted to the Vickers microhardness test in the top and in the base. Based on the results it was concluded that with the elevation of the temperature increased the Vickers hardness value with positive linear correlation on both devices. The hardness value of the top was always superior to the base hardness, independently of the light source or used temperatures. The halogen lamp source was superior to the source of LEDs in the area of base of the samples. / Orientador: Osmir Batista de Oliveira Junior / Coorientador: Vanderlei Salvador Bagnato / Banca: Sizenando de Toledo Porto Neto / Banca: Marcelo Giannini / Mestre
523

Avaliação da resistência ao cisalhamento de reparos de resina : interface tratada com laser de Er Yag, ponta diamantada e jato abrasivo com óxido de alumínio /

Rossato, Desirée Mory. January 2004 (has links)
Resumo: O objetivo deste trabalho foi realizar avaliação da resistên - cia de união ao cisalhamento de reparos de resina compostas em restaurações com resina composta envelhecidas, em função de diferentes tratamentos superficiais. Foram confeccionados 60 corpos-de-prova de resina composta Z250 (3M) e levados a termociclagem para simular o envelhecimento da restauração, foram realizados 500 ciclos de 15 segundos cada, variando entre 5°e 55°C. Separados aleatoriamente em seis grupos que sofreram os seguintes tratamentos superficiais: nenhum tratamento (G1 - controle), desgaste com ponta diamantada (G2), jato de óxido de alumínio com partículas de 27,5æm (G3) por 10 segundos, laser de Er:YAG - 200mJ (G4), laser de Er:YAG - 300mJ (G4) e laser de Er:YAG - 400mJ (G6), os três últimos com freqüência de 10Hz por 10 segundo. Foi realizada microscopia eletrônica de varredura para observarmos o aspecto do material após os tratamentos terem sido executados. O reparo da restauração foi realizado utilizando-se a mesma resina. O teste de cisalhamento foi feito na Máquina de Ensaios Mecânicos MTS - 810. Analisando os resultados por ANOVA e pelo teste de Tukey não foram encontradas diferenças significativas (p-valor=0.5120). A análise dos valores medianos, mostrou que o tratamento superficial com jato de óxido de alumínio apresentou uma maior resistência da interface do reparo ao cisalhamento (8.91Mpa) enquanto que o laser de Er:YAG com 400mJ de potência, apresentou a menor (6.76Mpa). A análise dos tipos de fratura mostrou que 90% dos corpos-de-prova do grupo 3 (óxido de alumínio) sofreram fraturas coesivas. / Abstract: The aim of this work was to perform the evaluation of the shear bond strength of the composite resin repairs in old composite restorations, modifying the superficial treatment of the samples. Sixty samples of the composite resin Z250 (3M) were prepared and thermocycled for 500 cycles at 5° and 55°C with a dwelling time of 15 seconds. Speciments were randomly divided into six groups and subjected to different surface treatments as follows: No surface treatment (G1 - control), grinding with a diamond bur (G2), sandblasting with a microetcher for 10 seconds with 27,5æm Al2O3 particles (G3), treated with Er:YAG laser with an energy intensity of 200mJ (G4), 300mJ (G5), 400mJ (G6), frequency of 10Hz for 10 seconds. The speciments after surface treatment were observed using the scanning electron microscope. The repair of the old resin was done with the same material. The shear bond strength test was performed in a Mechanic Testing MTS - 810. Statistical treatment by ANOVA and Tukey's test showed no significant differences between the groups tested (p=0.5120). The highest shear bond strength values were achieved by sandblasting the surface with a microetcher with Al2O3 (8,91Mpa), whereas the lowest values were obtained with Er:YAG laser with energy intensity of 400mJ (6.76Mpa). Observing the rupture surface, G3 presented 90% of cohesive failures. / Orientador: José Roberto Cury Saad / Coorientador: Rosane F. Z. Lizarelli / Banca: Celso Luiz de Angelis Porto / Banca: Elda Pisaneschi / Mestre
524

Influência de agentes clareadores na rugosidade de compósitos dentários / Influence of bleaching gels on roughness of dental composites

Eduardo Varanda 18 December 2009 (has links)
O clareamento dental é o meio disponível mais simples, comum e conservador para o cirurgião-dentista proporcionar aos pacientes o padrão de cor de seus dentes mais desejado. Em alguns casos, os dentes que vão ser clareados podem apresentar restaurações realizadas com compósitos dentais, que são mais suscetíveis a alterações químicas, quando comparados a outros materiais restauradores. Alguns estudos mostraram que diferentes concentrações de agentes clareadores levaram a um aumento significativo da rugosidade superficial e das porosidades em compósitos dentais. Este estudo avaliou o efeito de dois agentes clareadores (Whiteness HP Blue 20%, Whiteness HP Max) sobre a rugosidade superficial de dois compósitos dentais, um micro-híbrido (Esthet X, Denstply) e outro nanoparticulado (Z 350, 3M ESPE). Um total de oito corpos de prova (9 x 2 mm) foram confeccionados com auxílio de uma matriz de teflon, sendo divididos em 4 grupos (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), sendo n=2. Os corpos de prova foram armazenados em saliva artificial neutra e, após 24 horas, foram polidos com discos de óxido de Alumínio (Sof-lex, 3M ESPE). Após sete dias de imersão salivar, cada corpo de prova foi levado a um microscópio de força atômica para obtenção do valor inicial de rugosidade superficial (Ra em nm). Em seguida, sem remover o corpo de prova do microscópio, o agente clareador foi aplicado sobre a superfície do corpo de prova, segundo as instruções do fabricante, de modo que permitisse uma posterior observação da mesma área do corpo de prova observada inicialmente, para obtenção do valor final de rugosidade superficial. Imagens em duas e três dimensões foram obtidas de cada corpo de prova para observação de alterações da topografia. Os resultados foram tratados estatisticamente por ANOVA e pelo teste de contraste Student-Newman-Keuls (p < 0,05). Não houve alteração significativa na rugosidade superficial (Ra) dos corpos da prova de compósitos micro-híbrido e nanoparticulado, submetidos aos agentes clareadores Whiteness HP Blue 20% e Whiteness HP Maxx. No entanto, independente do agente clareador utilizado, foram observadas maiores alterações topográficas nas imagens de microscopia de força atômica da superfície do compósito micro-híbrido do que nas imagens do nanoparticulado. / Dental bleaching is the simplest, the most common and conservative available way for dentists to offer their patients the standard color of teeth more desired. In some cases, the teeth that will be bleached may include restorations made of resin composites, which are more prone to chemical alteration compared with other restoration materials. Some studies have showed that different concentrations of bleaching gels might lead to a significant increase in surface roughness and amount of porosities in composite resins. This study evaluated the effect of two bleaching gels (Whiteness HP Blue 20%, Whiteness HP Max) on surface roughness of two resin composites, micro-hybrid (Esthet X, Denstply) and nanoparticled (Z350, 3M ESPE). A total of eight specimens (9 x 2 mm) were produced with a Teflon mold help, and were divided into four groups (Esthet X + Whiteness HP Blue 20%; Esthet X + Whiteness HP Max; Z 350 + Whiteness HP Blue 20%; Z 350 + Whiteness HP Max), with n=2. They were stored in neutral artificial saliva and, after 24 hours, were polished with aluminium oxide discs (Sof-lex, 3M ESPE). After seven days of salivary immersion, each specimen was taken to an atomic force microscope for recording initial value of surface roughness (Ra in nm). After that procedure, without removing the specimen from microscope, the bleaching gel was applied on the surface of the specimen, following manufacturers instructions, in order to allow posterior observation of the same area of the specimen initially observed, for recording the final value of surface roughness. Two-dimensional and 3D images were taken from each specimen group for observation of surface alterations. The results were statistically analyzed by ANOVA and the SNK test (p< 0.05). There were no statistically significant differences in the surface roughness (Ra) for specimens of micro-hybrid and nanoparticled composites, submitted to the bleaching agents Whiteness HP Blue 20% and Whiteness HP Maxx. However, there were noticed larger surface alterations in atomic force microscope images on the surface of micro-hybrid composites than on the nanoparticled, independently of the bleaching agent used.
525

Resistência à fratura de dentes com preparos cavitários MOD restaurados com resina composta e fibra de vidro

Rodrigues, Fausto Borges January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:18Z (GMT). No. of bitstreams: 2 000392253-0.pdf: 813004 bytes, checksum: 92cc239906e68f814913bc5491cecb54 (MD5) license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / The aim of this study was to evaluate in vitro the effect of two types of glass fibers, unidirectional or woven, placed inside of MOD cavity preparations on fracture strength of endodontically treated molars, either restored with composite resin, or not. Ninety sound human third molars were extracted, embedded in acrylic resin blocks and randomly assigned to six groups (n=15). Group 1 G1 (sound teeth), control. Groups G2, G3, G4, G5 e G6 were subjected to the following procedures: G2 – MOD cavity preparation; G3 – MOD and endodontic treatment (ET); G4 –MOD + ET + composite resin restoration (CR); G5 – MOD + ET + unidirectional fiber (UF) + CR; G6 - MOD + ET + woven fiber (WF) + CR. The specimens were stored in physiological serum at 37oC for 24 hours. Later, a compressive force was applied by means of a universal testing machine at 1 mm/min speed, parallel to the long axis of the teeth until the fracture occurred. After mechanical test three types of fractures were classified: 1) pulp chamber floor; 2) cusp; 3) pulp chamber floor and cusp. The means of results (N) followed by the same letter do not represent a statistical difference by ANOVA and Tukey (p<0,05): G1 (4960)a, G2 (1926. 20)b, G3 (612. 84)c, G4(1813. 9)b, G5 (2024)b, G6 (1879)b. In the analysis of qualitative variables of G5 and G6, there was a tendency to fracture in the pulp chamber floor and cusp not benefic to restore the tooth integrity. It is possible conclude that inserting the unidirectional or woven glass fibers into MOD cavity preparations and restored with composite resin the fracture strength is similar to that obtained in molars filled with composite resin only. / A proposta deste estudo foi avaliar o efeito de dois tipos de fibras, uma trançada e outra unidirecional, inseridas no interior de cavidades MOD padronizadas na resistência à fratura de dentes molares tratados endodonticamente. Noventa dentes terceiros molares hígidos foram selecionados e montados em blocos acrílicos, sendo estes divididos em seis grupos de quinze (n=15). No grupo G1, os dentes mantiveram-se hígidos (controle). Os grupos G2, G3, G4, G5 e G6 receberam preparos cavitários MOD padronizados, sendo que nos grupos G3, G4, G5 e G6 foram realizados tratamentos endodônticos. Após o preparo dos dentes, estes foram restaurados com resina composta, no grupo G4, e no grupo G5 e G6 foram inseridas dois tipos de fibras, uma trançada e outra unidirecional, respectivamente. Após, os corpos de prova foram submetidos ao ensaio de resistência à fratura. Avaliou-se, também, qualitativamente as falhas classificando-as em fratura de cúspide, assoalho e cúspide mais assoalho, após o ensaio mecânico. Os resultados (N) obtidos foram (médias seguidas de mesma letra não apresentam diferença estatística para Anova e Tukey (p<0,05): Grupo G1 (4960)a, Grupo G2 (1926,20)b, Grupo G3 (612,84)c, Grupo G4 (1813,9)b, Grupo G5 (2024)b, Grupo G6 (1879)b. Conclui-se que a utilização de fibras trançadas ou unidirecionais no interior de cavidades MOD de dentes com tratamento endodôntico não melhora a resistência a compressão apresentando um padrão de fratura de assoalho mais cúspide não favorável à recuperação da peça dentária.
526

Longevidade e fatores associados à falha de restaurações adesivas de dentes decíduos / Longevity and factors associated with failure of adhesive restorations in primary teeth

Dalpian, Débora Martini January 2016 (has links)
O objetivo desta tese foi avaliar a longevidade e os fatores associados à falha de restaurações adesivas em dentes decíduos. Para isto, foram desenvolvidos dois estudos retrospectivos. No primeiro, foi feita a análise da longevidade de restaurações realizadas após a remoção seletiva de tecido cariado em dentes decíduos. Foram avaliados os prontuários de pacientes atendidos durante os anos de 2007 a 2012 no ambulatório de Odontopediatria da Universidade Federal do Rio Grande do Sul. Os critérios de inclusão previram a realização de pelo menos um procedimento de restauração com remoção seletiva de tecido cariado, em dente decíduo, e o acompanhamento clínico e/ou radiográfico. A amostra foi composta por 254 dentes de 118 pacientes, com período de acompanhamento de 1 a 50 meses. A sobrevida das restaurações, após 24 meses, foi de 51%, sendo constatada uma associação positiva entre a falha do procedimento e maiores valores do índice de placa visível (p=0.01). No segundo estudo, foi realizada uma avaliação da longevidade e dos fatores associados à falha de restaurações em dentes decíduos, após a remoção total e seletiva de tecido cariado. Para isso, foi desenvolvido um estudo retrospectivo, no curso de Odontologia do Centro Universitário Franciscano, com base nos prontuários de pacientes infantis, atendidos durante os anos de 2010 a 2016, que receberam pelo menos uma restauração em dente decíduo e tiveram um acompanhamento mínimo de seis meses. Foram incluídos 123 pacientes e 316 restaurações de resina composta ou cimento de ionômero de vidro. Após 3 anos, as restaurações apresentaram sobrevida de 54,4% e taxa de falha anual de 18,3%. A análise de Log-rank mostrou que a remoção seletiva de tecido cariado (p=0,03), o uso de base forradora de hidróxido de cálcio (p<0,01) e o cimento de ionômero de vidro (p=0,04) como material restaurador, resultaram numa menor sobrevida da restauração. A regressão de Cox ajustada demonstrou que restaurações realizadas com remoção seletiva de tecido cariado apresentam 3,41 (IC 95% 1,37;8,46) vezes maior risco de falha, quando comparadas à remoção total de tecido cariado. Conclui-se, então, que as restaurações em dentes decíduos, realizadas por alunos de graduação, possuem limitadas taxas de sobrevida e que fatores relacionados ao paciente e ao procedimento influenciam no desempenho da restauração. / The aim of this thesis was to evaluate the longevity and factors associated with failure of adhesive restorations in deciduous teeth. For this, two retrospective studies were carried out. In the first, the longevity of restorations performed after the partial removal of carious tissue in deciduous teeth was analyzed. The records of patients treated during the period from 2007 to 2012 were evaluated at the School of Dentistry, Federal University of Rio Grande do Sul. The inclusion criteria predicted the accomplishment of at least one restoration procedure with partial removal of carious tissue in deciduous tooth and clinical and / or radiographic follow-up. The sample consisted of 254 teeth from 118 patients with follow-up period from 1 to 50 months. The survival rate of restorations after 24 months was 51%, with positive association between procedure failure and higher visible plaque index values (p=0.01). In the second study, longevity and factors associated with failure of restorations in deciduous teeth after total and partial removal of carious tissue were evaluated. For that, a retrospective study was developed in the Dentistry course of the Franciscan University Center, based on the records of pediatric patients treated during the period from 2010 to 2016, who received at least one restoration in a deciduous tooth and had minimum follow-up of six months. The study included 123 patients and 316 composite resin or glass ionomer cement restorations. After 3 years, restorations presented survival rate of 54.4% and annual failure rate of 18.3%. The log-rank analysis showed that the partial removal of carious tissue (p= 0.03), the use of calcium hydroxide liner (p<0.01) and glass ionomer cement (p=0.04) as restorative material, resulted in shorter survival rate of restorations. Adjusted Cox regression showed that restorations performed with partial removal of carious tissue were 3.41 (95% CI 1.37-8.46) more likely of presenting greater risk of failure when compared to total removal of carious tissue. It could be concluded that restorations in deciduous teeth performed by undergraduate students have restricted survival rate and that factors related to patient and procedure influenced the performance of restorations.
527

Reprodutibilidade e comparação de diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores

Podestá Rodriguez, Karina January 2007 (has links)
O objetivo deste estudo foi comparar diferentes métodos de avaliação de restaurações de resina composta em dentes posteriores, assim como avaliar a concordância intra-examinador. Cento e trinta e seis restaurações oclusais de resina composta foram avaliadas por um examinador treinado usando os critérios modificados do USPHS para avaliar quatro características das restaurações: integridade marginal, forma anatômica, descoloração marginal e textura superficial. Três métodos diferentes foram estudados: clínico, fotográfico e modelos. A reprodutibilidade intra-examinador foi medida através do teste de Kappa e a comparação de métodos através dos testes não-paramétricos de Fischer e Wilcoxon. Os resultados mostraram que os valores de concordância intra-examinador foram melhores na avaliação de integridade marginal e forma anatômica através de modelos, e os valores foram similares entre a avaliação clínica e fotográfica para integridade marginal e descoloração marginal. A textura superficial apresentou os valores mais baixos de concordância intra-examinador para todos os métodos examinados. O método direto foi significantemente diferente que os métodos indiretos para todas as características avaliadas (p< 0,05). Entretanto, quando os métodos foram avaliados segundo a aceitabilidade clínica considerada pelo USPHS, os métodos não foram diferentes. Os métodos fotográfico e modelos detectaram defeitos que não foram percebidos pelo método clínico na avaliação da integridade marginal e da forma anatômica. As avaliações através de fotografias e modelos foram semelhantes em todas as características avaliadas com exceção da textura superficial (p< 0,05). Todos os métodos mostraram ser inadequados para a avaliação de textura superficial. Houve diferenças significativas entre o método direto e os métodos indiretos. Os métodos indiretos permitiram realizar observações mais detalhadas e críticas. Entretanto, o método clínico mostrou ter capacidade para diferenciar entre restaurações clinicamente aceitáveis e não-aceitáveis. / The aim of this study was to compare different methods for evaluating composite resin restorations in posterior teeth and to evaluate the reproducibility of each method by determining the intraexaminer agreement. One hundred and thirty six occlusal composite resin restorations were evaluated by a trained examiner using modified USPHS criteria to assess four restoration characteristics: marginal integrity, anatomic form, marginal discoloration and surface texture. Three different methods were studied: clinical, photographic and dental cast models. Kappa statistics was used to determine reproducibility and non-parametric Friedman and Wilcoxon tests to compare the methods. The results showed that the best intraexaminer agreement values were obtained for dental cast models evaluations for marginal integrity and anatomic form and were similar between photographic and clinical evaluations for marginal integrity and marginal discoloration. Surface texture showed the lowest degree of intraexaminer agreement with all the methods tested. Direct clinical method and the two indirect methods were significantly different for all the characteristics assessed (p< 0.05). However, when they were evaluated according to USPHS clinical acceptability, the methods did not differ. Photographs and dental cast models methods detected defects that the direct clinical method could not distinguish for marginal integrity and anatomic form. Photographs and dental cast models evaluations were similar for all the characteristics assessed, except for surface texture (p< 0.05). All the methods showed that they are not adequate to evaluate surface texture. There were significant differences between the direct clinical method and the indirect methods for all the composite resin restorations characteristics assessed. The indirect methods allowed more detailed and critical observations. However, the direct clinical method was able to distinguish between clinical acceptable and unacceptable restorations.
528

Avaliação da resistencia de união de sistemas adesivos e cimentos resinosos a dentina e aos compositos restauradores / Evaluation of bond strength of adhesive systems and resincements to dentin and restorative composites

Garcia, Rubens Nazareno 26 May 2006 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T14:18:38Z (GMT). No. of bitstreams: 1 Garcia_RubensNazareno_D.pdf: 8662671 bytes, checksum: 0068fe648efbd833ec4737acd0f008f2 (MD5) Previous issue date: 2006 / Resumo: O atual conceito de união aos tecidos duros dentais é baseado na infiltração de sistemas adesivos em esmalte e dentina, no processo chamado de hibridização. Enquanto a união ao esmalte tem sido considerada um procedimento confiável devido a sua uniforme composição, a união à dentina continua sendo um desafio. O objetivo deste estudo foi avaliar e discutir os conceitos que envolvem os sistemas adesivos odontológicos e as técnicas de cimentação adesiva. O estudo compreendeu quatro avaliações que propuseram analisar: 1- a resistência de união (RU) de alguns sistemas autocondicionantes após uma semana e um ano de armazenamento em água; 2- a RU de cimentos resinosos aos compósitos utilizados na reconstrução dental; 3 e 4- a RU de técnicas de cimentação adesiva. Foram utilizados dentes bovinos nos experimentos 1, 2 e 3; e ensaios de microcisalhamento. Para o experimento 4 foram utilizados dentes humanos e o ensaio de microtração. Os resultados indicaram que: 1- entre todos adesivos testados, o adesivo autocondicionante One-Up Bond F não apresentou redução na RU após um ano; 2- a RU foi maior quando se aplicou adesivo hidrófobo entre o compósito restaurador e o cimento resinoso; 3 e 4- o uso de uma camada intermediária de resina de baixa viscosidade e fotoativação dos cimentos resinosos resultou em maiores valores de RU entre o cimento resinoso e a dentina. Os resultados sugerem que a união à dentina ainda é instável para a maioria dos sistemas adesivos; na união do cimento resinoso ao compósito restaurador, os adesivos hidrófobos são as melhores opções; e as técnicas de cimentação adesiva apresentam melhor desempenho com aplicação de uma camada intermediária de resina de baixa viscosidade e fotoativação do cimento resinoso / Abstract: The current concept of bonding to hard dental tissues is based on the infiltration of adhesive systems in enamel and dentin, in the so-called hybridization process. While the enamel bond has been considered a reliable procedure due to its uniform composition, bonding to dentin continues to present challenges. The objective of this study was to assess and discuss the concepts involving dental adhesive systems and the techniques of adhesive cementation. The study included four evaluations to determine: 1- the bond strength (BS) of some self-etching adhesive systems after one week and one year of storage in water; 2- The BS of the resin cements to composites used in dental restoration; 3 and 4- The BS of adhesive cementation techniques. Bovine teeth and micro-shear bond strength tests were used for experiments 1, 2 and 3. For experiment 4, human teeth and micro-tensile tests were used. The results indicated that: 1- among the adhesives tested, the self-etching adhesive One-Up Bond F did not show reduction in BS after one year; 2- the BS was higher when the hydrophobic bond was applied between the filling composite and the resin cement; 3 and 4- the use of an intermediary layer of low viscosity resins, and photoactivation of the resin cements, resulted in higher BS values between the resin cement and the dentin. The results suggest that bonding to dentin is still unstable for the majority of adhesive systems; in the union of the resin cement to the filling composite, hydrophobic adhesives are the best options; and the techniques of adhesive cementation present better performance with the application of an intermediate layer of low viscosity resin and photoactivation of resin cement / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
529

Profundidade de polimerização de cimentos resinosos : efeito de aparelhos fotoativadores e de materiais restauradores indiretos / In-depth polymerization of resin cements : effect of light curing units and indirect restorative materials

Tango, Rubens Nisie 04 March 2006 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-06T14:17:07Z (GMT). No. of bitstreams: 1 Tango_RubensNisie_D.pdf: 517454 bytes, checksum: 78bb278313f8acd3dca9e0eb5588eb01 (MD5) Previous issue date: 2006 / Resumo: Este estudo avaliou através do teste de dureza Knoop (KHN), a profundidade de polimerização do cimento resinoso Enforce, dual e fotoativado, quando fotoativados através da cerâmica (HeraCeram) ou do compósito (Artglass), com diferentes aparelhos fotoativadores. A fotoativação foi realizada com os aparelhos de luz de lâmpada halógena (XL2500) - QTH, luz emitida por diodos (Ultrablue 1s) - LED, ambos por 40 segundos, e aparelho de arco de plasma de xenônio (Apollo 95E) por 3 segundos - P AC. As faces vestibulares de incisivos bovinos foram planificadas e hibridizadas com o sistema adesivo Prime & Bond 2.1. Sobre estas superficies foi assentada uma matriz de borracha preta e opaca (lmm de espessura / 5mm de diâmetro), a qual foi preenchida com o cimento. Um disco de material para faceta (l,5mm de espessura) foi comprimido digitalmente sobre este conjunto para padronização da espessura de cimento e extravasamento dos excessos. A fotoativação foi realizada, com a ponta ativa dos aparelhos em contato com os illlteriais para faceta, sendo que nos grupos controle, a ativação foi realizada diretamente. Após armazenamento em ambiente seco e escuro (24h/37°C), as amostras (n=IO) foram seccionadas para mensuração dos valores de dureza (KHN), obtidos em aparelho microdurômetro (50gf de carga/ 15s). Os dados dos cimentos, dual e fotoativado, foram analisados separadamente. Para ambos, os dados foram submetidos à análise de variância de 3 fatores. Posteriormente, para o cimento dual foi aplicado o teste de Tukey e para o cimento fotoativado, o teste de Duncan (a=0,O5). Para ambos os cimentos, foram verificados que os valores de dureza diminuem com o aumento da profundidade de polimerização. Além disso, para ativação direta e através de HeraCeram, os maiores valores de dureza foram obtidos com LED, seguido por QTH e P AC. Para Artglass, no modo dual, valores de dureza similares foram obtidos com os 3 aparelhos fotoativadores. Já no modo foto ativado, os maiores valores foram obtidos com QTH, seguido pelo LED e P AC, respectivarrente. O aparelho P AC, com tempo de exposição de 3 segundos, mostrou-se ineficaz na polimerização do cimento no modo fotoativado através dos materiais para faceta. O efeito dos materiais para faceta foi distinto para cada aparelho foto ativador / Abstract: This study evaluated the polymerization depth of the dual-cure and light-cure resin cement Enforce, light-cured through ceramic (HeraCeram), or composite (Artglass), with different light curing units, by Knoop hardness (KHN) test. Light curing was carried out using conventional quartz tungsten halogen light (XL2500) - QTH, light emitting diodes (Ultrablue ls) - LED, both for 40s and, xemn plasma are (Apollo 95E) for 3s P AC. Bovine incisors had their buccal faces flattened and hybridized with the bond agent rime & Bond 2.1. On these surfaces, a black opaque mold (lmm thickness/ 5mm in diameter) was seated and filled with cement. A disc of the veneering material (l.5mm thickness) was compressed digitally over this set for cement thickness standardization and excesses remova!. Light curing was carried out with the light curing unit tip in contact with the veneering materiaIs. ln the control groups, resin cement was light cured directly. After dry storage at dark (24h/37°C), samples (n=lO) were sectioned for hardness (KHN) measurements, taken in a microhardness tester (50gf load/ 15s). Data of resin cement hardness, for dual cure and light cure, were analyzed separately. For both, data were submitted to three-way ANOV A. After that, Tukey's test was applied for dual cure resin cement, and for light cure cement Duncan's test was used (cx=.05). For both cements, it was verified that hardness decreased with the increase in polymerization depth. Besides that, for direct light curing and for light curing through HeraCeram, the highest hardness values were obtained with LED, followed by QTH and P AC. ln the dual cure resin cement beneath Artglass, similar hardness values were verified with the 3 light curing units. However, in light cure resin cement, the highest means were observed with QTH, followed by LED and PAC, respectively. PAC showed to be inefficient to polymerize the light cure resin cement beneath veneering materiaIs with 3s exposure time. The light transmission attenuating effect of veneering materiaIs was distinct for each light-curing unit / Doutorado / Materiais Dentarios / Mestre em Materiais Dentários
530

Efeito da armazenagem em NaOCl na degradação morfologica da interface adesiva e na resistencia de união em diferentes substratos / Effect of NaOCl storage on morphologic degradation of adhesive interface and bond strength in different substrates

Valentino, Thiago Assunção 15 February 2007 (has links)
Orientadores: Luiz Andre Freire Pimenta, Lourenço Correr Sobrinho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T18:37:31Z (GMT). No. of bitstreams: 1 Valentino_ThiagoAssuncao_M.pdf: 33208197 bytes, checksum: 1b097596ca0a13008a544ccb8786f3f2 (MD5) Previous issue date: 2007 / Resumo: O objetivo deste estudo in vitro foi analisar o efeito da armazenagem em solução de hipoclorito de sódio a 10% (NaOCl), para acelerar a degradação hidrolítica e simular o envelhecimento da interface adesiva ao longo do tempo, através da avaliação da resistência de união adesiva com a utilização do teste de microtração. A solução de hipoclorito de sódio a 10% é usada em curtos períodos de tempo (horas) resultando em decréscimo significante da resistência de união no substrato dentinário após a armazenagem nesta solução; entretanto, o mecanismo de degradação gerado por esta solução não é totalmente compreendido, desde que o NaOCL é um agente proteolítico nãoespecífico, que poderia degradar não apenas as fibrilas colágenas expostas não encapsuladas na camada híbrida, mas também a interface adesiva. Foram avaliados 2 sistemas adesivos comercialmente disponíveis: um sistema adesivo de frasco único Single Bond (SB) e um sistema adesivo contendo primer autocondicionante Clearfil SE Bond (SE). Foram utilizados neste experimento, 80 incisivos bovinos hígidos, 40 para esmalte e 40 para dentina, e 40 blocos confeccionados em resina composta, totalizando 120 unidades experimentais divididas em 12 grupos (n = 10). Após a restauração com resina composta Filtek Z250, a amostra foi armazenada em água destilada por 24 horas, a 37 'GRAUS'C. Para a realização do teste de microtração, as unidades experimentais foram cortadas em forma de palitos de 1 mm2 e 8 palitos de cada unidade experimental foram armazenados em solução de hipoclorito de sódio a 10 % (NaOCl) por 2 horas (Grupos experimentais) ou em água destilada (H2O) por 24 horas (Grupos controle). O padrão de fratura foi observado com o auxílio da Microscopia Eletrônica de Varredura e foram realizadas fotomicrografias em magnitude de 80X para classificação do padrão de fratura e 1000X para caracterização dos detalhes das regiões mais expressivas das superfícies analisadas. As médias convertidas em MPa para os valores de união foram analisadas pelo teste de Análise de Variância (ANOVA) fatorial (3X2X2) e teste de Tukey para comparação das médias, ambos ao nível de 5 %. Os valores médios de microtração foram: Esmalte/NaOCl/SB = 29.3(4.0) a; Esmalte/NaOCl/SE = 20.7(3.4) b; Esmalte/H2O/SB = 31.2(5.0) a; Esmalte/H2O/SE = 20.8(2.9) b; Dentina/NaOCl/SB = 13.5(1.6) c; Dentina/NaOCl/SE = 7.5(1.1) d;Dentina/H2O/SB = 34.9(3.4) a; Dentina/H2O/SE = 20.3(3.7) b;ResinaComposta/NaOCl/SB = 24.1(7.0) b; ResinaComposta/NaOCl/SE = 42.8(4.7) a;ResinaComposta/H2O/SB =26.6(2.7) b; ResinaComposta/H2O/SE = 41.3(3.5) a. O padrão de fratura foi predominantemente adesivo para os substratos esmalte e resina composta,independentemente do sistema adesivo empregado e, para dentina, o padrão de fratura para a armazenagem em H2O foi predominantemente adesivo e para a armazenagem em NaOCl foi predominantemente na área de degradação. A armazenagem em NaOCl apresentou maior potencial significante de degradação e desproteinização para o substrato dentinário e o sistema autocondicionante empregado apresentou uma menor suscetibilidade à degradação. Este experimento in vitro provou ser efetivo na degradação de apenas das fibrilas colágenas na dentina, este método poderia útil para se predizer o desempenho clínico dos sistemas adesivos / Abstract: The purpose of this in vitro study was to investigate the fast effect of the 10 % hypochrorite sodium storage in simulation to hydrolytic degradation and adhesive interface aged for long time, through to evaluate the bond strength of microtensile bond test. The 10% NaOCl solution used in short periods of time (hours) resulting in a significant decrease in bond strength in dentin after storage in that solution; however the mechanism of degradation generated by this solution is not totally understood, since sodium hypochlorite is a non-specific proteolytic agent, which could degrade not only the exposed collagen fibrils underneath the hybrid layer, but also the adhesive interface. For 2 adhesive systems avaliable commercially: one-bottle total-etch adhesive system Single Bond (SB) and primer self-etching adhesive system Clearfil SE Bond (SE). For this study, 80 ound bovine incisors, 40 for enamel and 40 for dentin, and 40 blocks building-up in composite resin, entirety 120 experimental units (n = 10). After sample restoration with resin composite Filtek Z250, the sample was storaged in distilled water at 37° C for 24 hours. For the microtensile bond test performance, the experimental units was sectioned into 1 mm² beams and 8 beams for each experimental unit was storaged in 10 % hypochrorite sodium (NaOCl) for 2 hours (Experimental groups) or in destilled water (H2O) for 24 hours (Control groups), entirety 960 beams observed. The failure pattern was observed in Scanning Electron Microscope (MEV) and photomicrographs was accomplished in 80X magnification for failure pattern classification and 1000X for details characterization of the more expressive areas for analysed surfaces. The means converted in MPa for the bond strength values were analysed by the Statistical Analysis (ANOVA) fatorial (3X2X2) and Tukey test for multiple comparison, both at level 5%. The means values for the microtensile test were: Enamel/NaOCl/SB = 29.3(4.0) a; Enamel/NaOCl/SE = 20.7(3.4) b; Enamel/H2O/SB = 31.2(5.0) a; Enamel/H2O/SE = 20.8(2.9) b; Dentin/NaOCl/SB = 13.5(1.6) c; Dentin/NaOCl/SE = 7.5(1.1) d; Dentin/H2O/SB = 34.9(3.4) a; Dentin/H2O/SE = 20.3(3.7) b; ResinComposite/NaOCl/SB = 24.1(7.0) b; ResinComposite/NaOCl/SE = 42.8(4.7) a; ResinComposite/H2O/SB =26.6(2.7) b; ResinComposite/H2O/SE = 41.3(3.5) a. The failure pattern was predominantly adhesive for the substrates enamel e resin composite, independently adhesive system utilized and, for dentin, the failure pattern for H2O storage was predominantly adhesive and for NaOCl storage was predominantly in degradation area. NaOCl storage showed a bigger degradation and desproteinization potencial significantly for the dentin substrate and the self-etching adhesive system tested showed smaller degradation susceptibility. This in vitro test proves to be effective in degrading just the collagen fibrils in dentin, this method might be very useful to predict the performance of the adhesive systems in clinics / Mestrado / Dentística / Mestre em Clínica Odontológica

Page generated in 0.1819 seconds