• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 261
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 265
  • 265
  • 169
  • 160
  • 56
  • 49
  • 48
  • 43
  • 43
  • 41
  • 37
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Estimativa da resistência não drenada (Su) mediante o cálculo da energia de cravação do SPT / Estimating the undrained shear strength (Su) by calculating the energy of pile driving of the SPT / Estimativa de la resistencia no drenada (Su) mediante el cálculo de la energía de penetración del SPT

Muñoz Rodriguez, Camilo Andrés January 2012 (has links)
A presente dissertação tem por objetivo desenvolver um método para o cálculo da resistência não drenada (Su) através de uma metodologia que considera o cálculo da energia do ensaio SPT, partindo dos conceitos inicialmente propostos por Odebrecht (2003). Através de uma pesquisa bibliográfica foi gerado um banco de dados de estudos de casos executados em solos argilosos, em locais nos quais foram realizadas investigações geotécnicas extensivas, incluindo resultados de ensaios SPT e valores de Su obtidos através de outros ensaios de campo ou laboratório. Estes dados subsidiam a análise e formulação da proposta baseada em uma equação que combina o cálculo da energia desenvolvida durante o ensaio SPT à capacidade de carga estática por equilíbrio limite para uma estaca individual (proposta por Poulos e Davis, 1980). Foram definidas duas formas de calcular Su, diferenciadas pelo coeficiente de ajuste da força de atrito na capacidade de carga: α segundo proposta de Tomlinson (1969) e λ proposto por Vijayvergiya e Focht (1972). As formulações não produziram estimativas de Su compatíveis com valores medidos em outros ensaios e, por esta razão, foi proposta uma formulação alternativa para calcular α e λ como função direta do NSPT. Esta função é empírica e baseada em ajustes estatísticos. Dos processos de cálculo e avaliações conclui-se que o método proposto para a estimativa de α oferece resultados coerentes com os observados em ensaios de campo (piezocone e palheta). As estimativas de resistência não drenada apresentam considerável dispersão de resultados, com coeficiente de correlação médio r2 de 0,65. A dispersão é inerente a estimativas baseadas em ensaios SPT devido à diversidade de procedimentos usados na sua execução e, por este motivo, recomenda-se o uso destas correlações somente em nível de anteprojeto. / The present dissertation aims at developing a method for calculating the undrained shear strength Su using the methodology developed by Odebrecht’s (2003) based on the energy transmited by the SPT test. Through a bibliographic research, a database was created showing different case studies in clays in places where comprehensive geotechnical information is available. As a minimum requirement for selecting a case, the results of both the SPT test and the estimative of Su (from field or laboratory test) have to be registered. These results subsidized an analysis and the formulation of the proposed method, based on the equation that combines the theory for energy conservation to the static load capacity of a pile with the methodology of limit equilibrium analysis, suggested by Poulos and Davis (1980). Two different ways of calculating Su were defined. They were differentiated by the coefficient of adjustment of the frictional force: α as proposed by Tomlinson (1969) and λ by Vijayvergiya and Focht (1972). The formulations did not produce compatible estimates of Su with measureable values in other tests. For this reason a proposal was made to calculate both α and λ as a direct function of NSPT. This function is empirical and is based on statistical analysis. From the calculations, the proposed method of α is recommended based on the fact that it produces results that are comparable to those obtained from other field tests (piezocone and vane). The predicted values of undrained shear strength exhibit considerable dispersion of results, with an r2 correlation coefficient medium of 0.65. The dispersion is inherent to the estimates based on the tests of SPT due to the diversity of procedures/processes used in its execution and, for this motive, the use of these correlations are recommended only in preliminary projects. / La presente disertación tiene por objetivo desarrollar un método para el cálculo de la resistencia no drenada (Su) mediante una metodología que considera el cálculo de la energía del ensayo SPT, partiendo de los conceptos inicialmente propuestos por Odebrecht (2003). Mediante una investigación bibliográfica se generó un banco de datos de estudios realizados en suelos arcillosos, en locales donde fueron realizados investigaciones geotécnicas extensivas, incluyendo resultados de ensayos SPT y valores de Su obtenidos a través de otros ensayos de campo o laboratorio. Estos datos apoyan el análisis y la formulación de la propuesta basada en la ecuación que combina el cálculo de la energía desarrollada durante el ensayo SPT y la capacidad de carga estática por equilibrio límite para pilotes unitarios (propuesta por Poulos y Davis, 1980). Fueron definidas dos formas de calcular Su, diferenciadas por el coeficiente de ajuste de la fuerza de fricción en la capacidad de carga: α según propuesta de Tomlinson, 1969 y λ propuesto por Vijayvergiya y Focht, 1972. Estas formulaciones no produjeron estimativas de Su compatibles con valores medidos en otros ensayos y, es por esta razón que se propone una formulación alternativa para calcular α y λ como función directa del NSPT. Se trata de una función empírica basada en ajustes estadísticos. De los procesos de cálculo y evaluaciones realizados se concluye que el método propuesto para la estimativa de α ofrece resultados coherentes con los observados en ensayos de campo (piezocono y veleta). Las estimaciones de resistencia no drenada presentan una considerable dispersión de resultados, con coeficiente de correlación r2 del orden de 0,65. La dispersión es inherente a estimativas basadas en ensayos SPT debido a la diversidad de procedimientos usados para su ejecución, por este motivo se recomienda el uso de estas correlaciones solamente al nivel de anteproyecto.
232

Avaliação das trajetórias de umedecimento e secagem na deformabilidade elástica de solos compactos

Weber, Rodrigo Carreira January 2013 (has links)
Este trabalho analisa os efeitos das trajetórias de umedecimento e secagem no módulo de resiliência e cisalhamento direto quanto à resistência e deformabilidade elástica de solos compactados através de ensaios triaxiais de carga cíclica e ensaios de cisalhamento direto. O solo estudado é oriundo de jazida localizada próximo à BR116/RS, no município de Guaíba, sendo usualmente utilizado como material para execução de aterros rodoviários. As curvas de retenção do solo foram obtidas pelo método de papel filtro para solos compactados com variação de teor de umidade ótima de ±2%. Os estudos de módulo de resiliência e de resistência ao cisalhamento foram analisados nestas condições e demonstraram que o efeito do teor de umidade é significativo nas trajetórias de secagem e umedecimento. As curvas de retenção mostraram diferentes formas de acordo com a umidade de compactação e apresentaram histerese após a amostra ser submetida à trajetória de secagem. Observou-se que os solos compactados no ramo seco apresentaram valores mais elevados de módulo de resiliência e de resistência ao cisalhamento que aqueles que se encontravam no ramo úmido da curva de compactação. Uma análise do solo compactado no ramo seco e umedecido posteriormente até o ramo úmido teve comportamento semelhante aos moldados neste ramo. Por outro lado, na trajetória de secagem dos solos compactados no ramo úmido observou-se um aumento na resistência. Os modelos de desempenho para módulo de resiliência apresentaram boas correlações e para os que utilizam a sucção, observa-se um comportamento diferente com relação aos que não utilizam e com relação às constantes de cada modelo. / This paper analyzes the effects of wetting and drying paths in resilient modulus and shear strength for resistance and elastic deformability of compacted soils through triaxial cyclic load tests and direct shear tests. The soil studied is derived from BR116/RS near the Guaiba’s city, usually being used for subgrade. The retention curves of the soil were obtained by the filter paper method, with optimum moisture content varying a range of ± 2%. The studies of resilient modulus and shear strength were analyzed in these conditions and showed that the effect of moisture content is significant in the drying and wetting trajectories. The retention curves showed different forms according to the moisture content in the compaction, showed hysteresis after the specimen is subjected to the drying trajectory. It was observed that the soils compacted and tested in the dry branch had higher resilient modulus and shear strength than those compacted in the wet branch. An analysis of the soil compacted in the dry branch and subsequently dampened up to the wet branch had similar behavior to the soil molded ah this branch. On the other hand, in the trajectory of drying of the compacted soil at wet branch there is an increase in resistance. Performance models for resilient modulus showed good correlations and those using suction, observe a different behavior with respect to that use and not with respect to the constants of each model.
233

Estudo do comportamento de pavimentos de concreto simples em condições de aderência entre placa de concreto e base cimentada ou asfáltica. / Study of concrete pavement behavior in bonding condition between concrete slab and cemented or asphalt base.

Deividi da Silva Pereira 31 July 2003 (has links)
Motivado pela alteração do sistema construtivo de pavimentos de concreto de cimento Portland, na qual foi abolida a utilização da manta plástica entre placas e bases cimentadas, com conseqüente emprego de imprimação da base com emulsão asfáltica, este trabalho buscou responder algumas indagações surgidas durante este processo. Em laboratório, através de uma metodologia de ensaio especialmente adaptada para o estudo da resistência ao cisalhamento entre concreto de cimento Portland (CCP) e concreto compactado com rolo (CCR), inferiu-se, para diferentes tratamentos de interface, elevados níveis de resistência ao cisalhamento em interfaces sem emulsão asfáltica que potencializam o emprego de estruturas monolíticas de pavimentos. Quanto àquelas que continham material asfáltico, foram obtidos resultados muito inferiores aos anteriores, com caracterização de ruptura dúctil, por efeito de fluência do material betuminoso. Duas pistas experimentais instrumentadas, uma em whitetopping ultradelgado e outra em pavimento simples de concreto executado segundo a nova prática construtiva, capazes de mensurar as deformações específicas do CCP durante a execução de provas de carga dinâmica, associadas às modelagens por elementos finitos (MEF), realizadas com auxílio do programa ISLAB2000, propiciaram importantes inferências sobre o comportamento mecânico destes dois tipos de pavimentos de concreto. Verificou-se o trabalho mecânico composto (monolítico) das estruturas de whitetopping ultradelgado, com boas correlações entre as tensões medidas e numericamente calculadas; e entre os rebaixamentos da linha neutra (LN) determinados analítica, numérica e experimentalmente. No tocante ao pavimento simples de concreto sobreposto à base cimentada imprimada, apesar das ótimas correlações entre tensões medidas e determinadas numericamente, não se pode obter conclusões definitivas a despeito do trabalho mecânico desta estrutura, apesar da existência de indícios de comportamento não-monolítico. / This thesis intended to answer some inquiries, which arose during the alteration of the concrete pavement constructive process. This process substituted the plastic blanket by the asphalt emulsion, between the concrete slabs and the cemented bases. A laboratorial test methodology, specially adapted for the study of shear strength between the Portland cement concrete and the rolled concrete, inferred, for different types of interlayer treatments, high levels of shear strength, at the interfaces without asphalt emulsion. These shear strength levels enable the monolithic behavior of the pavement structure. When the asphalt emulsion was presented at the interlayer, the shear strength was much smaller than the former, with ductile rupture due to creep of the bituminous material. Two instrumented road tests, the first section in ultra-thin whitetopping pavement and de second one, in jointed plain concrete pavement (built according to new constructive process), and the finite element analyses led to important conclusions about the mechanical behavior of these pavement structures. This was possible because the strain-gages measured the specific concrete deformations during the dynamic load tests. The monolithic behavior of the ultra-thin whitetopping pavement was verified. There were good correlations between the measured stresses and theoretical stresses, which were calculated by the finite element method; and between the neutral axle displacements, estimated by analytical, numerical and experimental methods. With regard to the jointed plain concrete pavement, which was built over the cemented base (covered by the asphalt emulsion), great correlations between measured and simulated stresses were found, as well as it was found for ultra-thin whitetopping. However, it was not possible to conclude, definitively, concerning the mechanical behavior of this pavement structure, although there are clues that ndicated a non-monolithic behavior, that is, concrete slabs are unbounded up with the cemented base.
234

Estudo sobre a resistência ao cisalhamento de um solo residual compactado não saturado. / Study on the shear strength of a residual unsaturated soil.

Orlando Martini de Oliveira 22 June 2004 (has links)
O principal enfoque deste estudo é investigar alguns aspectos da resistência ao cisalhamento e as propriedades de retenção de água de um solo residual compactado no estado não saturado. Foi utilizado um solo residual de gnaisse retirado do campo experimental de geotecnia da Universidade de São Paulo. Com base na curva de compactação foram escolhidos três pontos de moldagem para o estudo, estando os mesmos associados à umidade ótima, ao ramo seco e ao ramo úmido. Foram realizadas algumas series de ensaios triaxiais sob condições saturadas (CAU e CD), e um grande número de ensaios triaxiais não saturados com teor de umidade constante (CW). Os ensaios triaxiais CW não saturados, foram feitos com medição de sucção utilizando um tensiômetro de alta capacidade (TAC) colocado na base do corpo de prova. Estudos específicos relacionados com a técnica de medição de sucção com o uso do TAC foram feitos. Com os resultados dos ensaios de resistência foram obtidas, para diferentes pressões confinantes, as variações dos valores da resistência ao cisalhamento (q) em função da sucção. Estas relações permitiram a definição das superfícies de ruptura para as três condições de moldagem. Foram investigados também aspectos relativos à forma de carregamento, a velocidade de carregamento, o tipo de compactação e a trajetória de umedecimento. São apresentados detalhes de como a resistência do solo é afetada por estas variáveis. O estudo define os procedimentos para obtenção das superfícies de resistência do solo no estado não saturado, com o uso de ensaios de compressão simples, feitos com medição de sucção durante o ensaio, e com a envoltória do solo saturado. As curvas de retenção do solo foram obtidas sob diversas condições de moldagem e umedecimento, e utilizado as técnicas de translação de eixos, placa de sucção, tensiômetro e papel filtro. Estas curvas foram utilizadas como ferramenta para se verificar a aplicabilidade dos modelos de previsão de resistência propostos por Vanapalli et al (1996) e Khalili e Khabbaz (1998), ao solo estudado. / The main focus of this study is to investigate some aspects of the shear strength and water retention properties of a compacted residual soil, under unsaturated condition. A residual of gneiss obtained from the geotechnical experimental site of the University of São Paulo was used. Based on the compaction curve three molding conditions were adopted for the study: one associated with the optimum water content, and two others located at the dry side and wet side of the compaction curve. A series of triaxial tests were performed under saturated conditions (CAU and CD), and a great number of triaxial tests under unsaturated conditions at constant water content (CW). The CW tests were performed with suction measurement using a high capacity tensiometer (HCT) placed at the base of the sample. Investigations were carried out associated with the use of the CHT. Based on the shear strength tests performed under different confining pressure the relation between shear strength and suction were determined. With this relation it was possible to define the shear surface for the three molding conditions. It were also investigated aspects related with type of loading, speed of the test, type of compaction and moisture path after compaction. It is presented details on how the shear strength is affected by these parameters. The study defines a procedure to obtain the shear surface of an unsaturated soil using unconfining tests, with suction measurement and using the shear envelope obtained at saturated condition. The retention curves were obtained at different molding conditions, following distinct moisture path. The retention curves were determined using axis translation technique, suction plate, filter paper and tensiometer. The retention curves were used as a tool to evaluate the applicability of the models presented by Vanapalli et al (1996) and Khalili and Khabbaz (1998) to infer the shear strength of the residual soil studied.
235

Estimativa da resistência não drenada (Su) mediante o cálculo da energia de cravação do SPT / Estimating the undrained shear strength (Su) by calculating the energy of pile driving of the SPT / Estimativa de la resistencia no drenada (Su) mediante el cálculo de la energía de penetración del SPT

Muñoz Rodriguez, Camilo Andrés January 2012 (has links)
A presente dissertação tem por objetivo desenvolver um método para o cálculo da resistência não drenada (Su) através de uma metodologia que considera o cálculo da energia do ensaio SPT, partindo dos conceitos inicialmente propostos por Odebrecht (2003). Através de uma pesquisa bibliográfica foi gerado um banco de dados de estudos de casos executados em solos argilosos, em locais nos quais foram realizadas investigações geotécnicas extensivas, incluindo resultados de ensaios SPT e valores de Su obtidos através de outros ensaios de campo ou laboratório. Estes dados subsidiam a análise e formulação da proposta baseada em uma equação que combina o cálculo da energia desenvolvida durante o ensaio SPT à capacidade de carga estática por equilíbrio limite para uma estaca individual (proposta por Poulos e Davis, 1980). Foram definidas duas formas de calcular Su, diferenciadas pelo coeficiente de ajuste da força de atrito na capacidade de carga: α segundo proposta de Tomlinson (1969) e λ proposto por Vijayvergiya e Focht (1972). As formulações não produziram estimativas de Su compatíveis com valores medidos em outros ensaios e, por esta razão, foi proposta uma formulação alternativa para calcular α e λ como função direta do NSPT. Esta função é empírica e baseada em ajustes estatísticos. Dos processos de cálculo e avaliações conclui-se que o método proposto para a estimativa de α oferece resultados coerentes com os observados em ensaios de campo (piezocone e palheta). As estimativas de resistência não drenada apresentam considerável dispersão de resultados, com coeficiente de correlação médio r2 de 0,65. A dispersão é inerente a estimativas baseadas em ensaios SPT devido à diversidade de procedimentos usados na sua execução e, por este motivo, recomenda-se o uso destas correlações somente em nível de anteprojeto. / The present dissertation aims at developing a method for calculating the undrained shear strength Su using the methodology developed by Odebrecht’s (2003) based on the energy transmited by the SPT test. Through a bibliographic research, a database was created showing different case studies in clays in places where comprehensive geotechnical information is available. As a minimum requirement for selecting a case, the results of both the SPT test and the estimative of Su (from field or laboratory test) have to be registered. These results subsidized an analysis and the formulation of the proposed method, based on the equation that combines the theory for energy conservation to the static load capacity of a pile with the methodology of limit equilibrium analysis, suggested by Poulos and Davis (1980). Two different ways of calculating Su were defined. They were differentiated by the coefficient of adjustment of the frictional force: α as proposed by Tomlinson (1969) and λ by Vijayvergiya and Focht (1972). The formulations did not produce compatible estimates of Su with measureable values in other tests. For this reason a proposal was made to calculate both α and λ as a direct function of NSPT. This function is empirical and is based on statistical analysis. From the calculations, the proposed method of α is recommended based on the fact that it produces results that are comparable to those obtained from other field tests (piezocone and vane). The predicted values of undrained shear strength exhibit considerable dispersion of results, with an r2 correlation coefficient medium of 0.65. The dispersion is inherent to the estimates based on the tests of SPT due to the diversity of procedures/processes used in its execution and, for this motive, the use of these correlations are recommended only in preliminary projects. / La presente disertación tiene por objetivo desarrollar un método para el cálculo de la resistencia no drenada (Su) mediante una metodología que considera el cálculo de la energía del ensayo SPT, partiendo de los conceptos inicialmente propuestos por Odebrecht (2003). Mediante una investigación bibliográfica se generó un banco de datos de estudios realizados en suelos arcillosos, en locales donde fueron realizados investigaciones geotécnicas extensivas, incluyendo resultados de ensayos SPT y valores de Su obtenidos a través de otros ensayos de campo o laboratorio. Estos datos apoyan el análisis y la formulación de la propuesta basada en la ecuación que combina el cálculo de la energía desarrollada durante el ensayo SPT y la capacidad de carga estática por equilibrio límite para pilotes unitarios (propuesta por Poulos y Davis, 1980). Fueron definidas dos formas de calcular Su, diferenciadas por el coeficiente de ajuste de la fuerza de fricción en la capacidad de carga: α según propuesta de Tomlinson, 1969 y λ propuesto por Vijayvergiya y Focht, 1972. Estas formulaciones no produjeron estimativas de Su compatibles con valores medidos en otros ensayos y, es por esta razón que se propone una formulación alternativa para calcular α y λ como función directa del NSPT. Se trata de una función empírica basada en ajustes estadísticos. De los procesos de cálculo y evaluaciones realizados se concluye que el método propuesto para la estimativa de α ofrece resultados coherentes con los observados en ensayos de campo (piezocono y veleta). Las estimaciones de resistencia no drenada presentan una considerable dispersión de resultados, con coeficiente de correlación r2 del orden de 0,65. La dispersión es inherente a estimativas basadas en ensayos SPT debido a la diversidad de procedimientos usados para su ejecución, por este motivo se recomienda el uso de estas correlaciones solamente al nivel de anteproyecto.
236

Avaliação das trajetórias de umedecimento e secagem na deformabilidade elástica de solos compactos

Weber, Rodrigo Carreira January 2013 (has links)
Este trabalho analisa os efeitos das trajetórias de umedecimento e secagem no módulo de resiliência e cisalhamento direto quanto à resistência e deformabilidade elástica de solos compactados através de ensaios triaxiais de carga cíclica e ensaios de cisalhamento direto. O solo estudado é oriundo de jazida localizada próximo à BR116/RS, no município de Guaíba, sendo usualmente utilizado como material para execução de aterros rodoviários. As curvas de retenção do solo foram obtidas pelo método de papel filtro para solos compactados com variação de teor de umidade ótima de ±2%. Os estudos de módulo de resiliência e de resistência ao cisalhamento foram analisados nestas condições e demonstraram que o efeito do teor de umidade é significativo nas trajetórias de secagem e umedecimento. As curvas de retenção mostraram diferentes formas de acordo com a umidade de compactação e apresentaram histerese após a amostra ser submetida à trajetória de secagem. Observou-se que os solos compactados no ramo seco apresentaram valores mais elevados de módulo de resiliência e de resistência ao cisalhamento que aqueles que se encontravam no ramo úmido da curva de compactação. Uma análise do solo compactado no ramo seco e umedecido posteriormente até o ramo úmido teve comportamento semelhante aos moldados neste ramo. Por outro lado, na trajetória de secagem dos solos compactados no ramo úmido observou-se um aumento na resistência. Os modelos de desempenho para módulo de resiliência apresentaram boas correlações e para os que utilizam a sucção, observa-se um comportamento diferente com relação aos que não utilizam e com relação às constantes de cada modelo. / This paper analyzes the effects of wetting and drying paths in resilient modulus and shear strength for resistance and elastic deformability of compacted soils through triaxial cyclic load tests and direct shear tests. The soil studied is derived from BR116/RS near the Guaiba’s city, usually being used for subgrade. The retention curves of the soil were obtained by the filter paper method, with optimum moisture content varying a range of ± 2%. The studies of resilient modulus and shear strength were analyzed in these conditions and showed that the effect of moisture content is significant in the drying and wetting trajectories. The retention curves showed different forms according to the moisture content in the compaction, showed hysteresis after the specimen is subjected to the drying trajectory. It was observed that the soils compacted and tested in the dry branch had higher resilient modulus and shear strength than those compacted in the wet branch. An analysis of the soil compacted in the dry branch and subsequently dampened up to the wet branch had similar behavior to the soil molded ah this branch. On the other hand, in the trajectory of drying of the compacted soil at wet branch there is an increase in resistance. Performance models for resilient modulus showed good correlations and those using suction, observe a different behavior with respect to that use and not with respect to the constants of each model.
237

Resistência de união de cimentos resinosos na dentina afetada por cárie induzida artificialmente

Peixoto, Aline Carvalho 21 November 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The bond strength of indirect restorations luted with self-adhesive resin cements to caries affected dentin has been poorly studied, despite this substrate be frequently found in cavity preparations. To standardize this substrate type, in vitro protocols of caries induction under controlled conditions are commonly used for bond strength tests. The aim of this study was to evaluate the bond strength of self-adhesive resin cements RelyX U200 and BisCem, and regular resin cement RelyX ARC to caries-affected dentin induced artificially. A microcosm biofilm from saliva of a donator was inoculated over dentin samples from caries-free human third molars and cultivated under anaerobic conditions for 14 days. It was used a model with intermittent availability of 1% sucrose for 4 hours per day. Cylinders of each resin cement were build-up on sound and caries-affected dentin surface (n=24). The cylinders were submitted to microshear testing after 24 hours. Vicker’s hardness (VH) and elastic modulus (E) were measured in both substrates until the depth of 200 μm. Data of bond strength were submitted to two-way ANOVA followed by Student-Newman-Keuls (SNK) multiple comparisons test; and the failure mode was evaluated by Fisher’s Exact and Chi-Square tests (P < 0.05). Data of VH and E were submitted to split-plot ANOVA and SNK’s test (P < 0.05). Caries-affected dentin presented the lower values of VH and E than sound dentin until the depth of 50 and 100 μm, respectively. The bond strength of all cements was lower on caries-affected dentin than sound dentin. Bond strength of RelyX U200 was similar to RelyX ARC and higher than BisCem, independently of substrate. In conclusion, the resin cements evaluated showed lowest bond strength values to caries-affected dentin, which presented lower mechanical properties than sound dentin near to surface where the adhesive procedures were performed. / A resistência de união de restaurações indiretas cimentadas com cimentos resinosos autoadesivos na dentina afetada por cárie tem sido pouco estudada, apesar de esta ser frequentemente encontrada em preparos cavitários. Para padronizar este tipo de substrato, protocolos in vitro de indução de cárie sob condições controladas são comumente empregados para testes de resistência de união. O objetivo deste estudo foi avaliar a resistência de união dos cimentos resinosos autoadesivos RelyX U200 e BisCem, e do cimento resinoso convencional RelyX ARC, na dentina afetada por cárie induzida artificialmente. Biofilmes de microcosmos originados da saliva de um doador, foram cultivados em condições de anaerobiose por 14 dias e formados sobre as amostras de dentina de terceiros molares humanos livres de cárie. Utilizou-se o regime de alimentação intermitente de sacarose à 1% em meio de cultura por 4 horas diárias. Cilindros de cada cimento resinoso foram confeccionados nas superfícies de dentina afetada por cárie ou hígida (n= 24). Os cilindros foram submetidos ao ensaio de microcisalhamento após 24 horas. A dureza Vickers (VHN) e módulo de elasticidade (E) foram medidos nos dois substratos avaliados até a profundidade 200 μm. Os dados de cisalhamento foram submetidos à Análise de Variância (ANOVA) de dois fatores, seguido pelo teste de comparações múltiplas de Student-Newman-Keuls (SNK), e o padrão de falha foi avaliado pelo teste Exato de Fisher e Qui-quadrado (P < 0,05). Os dados de VHN e E foram submetidos a ANOVA de parcela subdivida e teste de SNK (P < 0,05). A dentina afetada por cárie apresentou menores valores de VHN e E do que a dentina hígida até as profundidades de 50 e 100 μm, respectivamente. A resistência de união de todos os cimentos foi menor na dentina afetada por cárie que na dentina hígida. A resistência de união do RelyX U200 foi similar à do Relyx ARC e maior que a do BisCem, independente do substrato. Concluiu-se que os cimentos resinosos avaliados mostraram uma menor resistência de união na dentina afetada por cárie, que apresentou menores propriedades mecânicas que a normal próximo à superfície onde foi realizado os procedimentos de união.
238

Construção e testes de um penetrômetro de queda livre para caracterização do perfil de resistência ao cisalhamento de solos marinhos

Baldez, Anderson Lena January 2010 (has links)
Dissertação(mestrado) - Universidade Federal do Rio Grande, Programa de Pós-Graduação em Engenharia Oceânica, Escola de Engenharia, 2010. / Submitted by Lilian M. Silva (lilianmadeirasilva@hotmail.com) on 2013-04-15T00:06:33Z No. of bitstreams: 1 baldez,a.l.pdf: 8426528 bytes, checksum: 47e41efbe0e6ba9d1074f9667287d13a (MD5) / Approved for entry into archive by Bruna Vieira(bruninha_vieira@ibest.com.br) on 2013-06-10T18:46:55Z (GMT) No. of bitstreams: 1 baldez,a.l.pdf: 8426528 bytes, checksum: 47e41efbe0e6ba9d1074f9667287d13a (MD5) / Made available in DSpace on 2013-06-10T18:46:55Z (GMT). No. of bitstreams: 1 baldez,a.l.pdf: 8426528 bytes, checksum: 47e41efbe0e6ba9d1074f9667287d13a (MD5) Previous issue date: 2010 / Este trabalho tem por objetivo o desenvolvimento, construção e testes preliminares de um penetrômetro de queda livre para a caracterização de solos marinhos. O aparelho tem por finalidade medir as características de resistência do solo oceânico, através da medição e analise da desaceleração imposta ao penetrômetro após o seu impacto com o fundo. Este tipo de equipamento evita os elevados custos envolvidos em outros tipos de ensaios e na obtenção de amostras do fundo em condições de elevado risco e dificuldades naturais impostas pelas condições locais do mar. O dispositivo tem o formato de um aerofólio Joukowski simétrico (formato de gota), que consiste de duas partes: a primeira onde fica o acelerômetro e o chumbo granulado e a segunda onde há um conector que liga o acelerômetro a um cabo de dados e daí a um computador portátil que realiza a aquisição de dados. O penetrômetro pode ser lançado de certa altura acima da superfície da água, entra na água e mobiliza resistência hidrodinâmica durante a queda livre. Após choca-se contra o fundo marinho mobilizando resistências ao cisalhamento do solo sendo desacelerado até o repouso. Para os testes de funcionamento do equipamento foi utilizada a marina do Rio Grande Yacht Club localizado na cidade de Rio Grande - RS. Nos testes foram obtidos sinais de desaceleração registrados pelo acelerômetro que foram integrados numericamente duas vezes, a primeira obtendo dados de velocidade e na segunda dados de deslocamento percorrido pelo penetrômetro. Os dados assim coletados permitiram uma estimativa do perfil de resistência ao cisalhamento do solo marinho ao longo do comprimento penetrado,observando que o penetrômetro adquiriu a velocidade terminal sendo mensurada em torno de 5,7 m/s e o deslocamento máximo registrado obtido na marina foi de 5 metros. / This study aims at developing, constructing and testing a free fall penetrometer for the characterization of marine soils. The objective of this device is to measure the strength characteristics of the marine soil, through the measurement and the analysis of the deceleration imposed by its impact on the bottom.This kind of equipment reduces high costs involved in other tests and in the collection ofsamples on the bottom under bad sea conditions regarding risks and natural obstacles. The device was shaped as a symmetric Joukowski airfoil (the shape of a drop) which consists of two parts: one of them holds the accelerometer and the granulated lead and the other one has a connector that links the accelerometer to a data cable, and then, to a portable computer which collects the data. The penetrometer can be launched from a certain height above the water surface, and then penetrates into the water and mobilizes hydrodynamic resistance during the free fall. When it hits the bottom of the sea, it mobilizes shear strength and decelerates until it rests. The tests with the equipment were carried out in the marina at the Rio Grande Yacht Club located in Rio Grande, RS, Brazil. The tests got deceleration signals which wererecorded by the accelerometer and were integrated twice numerically in order to collectdata on the velocity and on the displacement of the penetrometer. These data enabled the estimate of the shear strength profile of the marine soil along the length in which penetration occurred. The datashow that the velocity of the penetrometer reached about 5.7 m/s and thatthe maximum displacement recorded in the marina was 5 meters.
239

Influência dos agentes de limpeza cavitária na resistência ao cisalhamento por extrusão de pinos de fibra de vidro cimentados com cimento resinoso autocondicionante / Influence of cavity cleaning agents on bond strength of glass fiber post cemented with self-etching resin cement

Atalla, Lara Gouvêa Almeida Martins 10 December 2009 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-01-12T12:51:08Z No. of bitstreams: 1 laragouveaalmeidamartinsatalla.pdf: 1481439 bytes, checksum: 5170ffd61eff8e2caba1d16c0795e644 (MD5) / Approved for entry into archive by Diamantino Mayra (mayra.diamantino@ufjf.edu.br) on 2017-01-31T11:16:46Z (GMT) No. of bitstreams: 1 laragouveaalmeidamartinsatalla.pdf: 1481439 bytes, checksum: 5170ffd61eff8e2caba1d16c0795e644 (MD5) / Made available in DSpace on 2017-01-31T11:16:46Z (GMT). No. of bitstreams: 1 laragouveaalmeidamartinsatalla.pdf: 1481439 bytes, checksum: 5170ffd61eff8e2caba1d16c0795e644 (MD5) Previous issue date: 2009-12-10 / O presente estudo teve como objetivo avaliar a influência do tratamento da dentina radicular com clorexidina a 2% e ácido cítrico a 10% na resistência de união de pinos de fibra de vidro cimentados com cimento resinoso RelyX Ultimate (3M ESPE) associado a um adesivo autocondicionante Single Bond Universal (3M ESPE). Quarenta e cinco dentes humanos unirradiculares foram selecionados e seccionados na junção cemento-esmalte, padronizando-os com 14 mm de comprimento. Após tratamento endodôntico, as raízes foram divididas aleatoriamente em 3 grupos (n=15) de acordo com o tratamento prévio do conduto radicular: G1, nenhum tratamento; G2, aplicação de gel de clorexidina a 2% (Rioquímica®) por 60 segundos; G3, aplicação de ácido cítrico a 10% (Idem per Idem Farmácia de Manipulação Ltda) por 60 segundos. Posteriormente, foi aplicado o adesivo nos condutos e nos pinos de fibra de vidro (White Post, FGM) e estes foram cimentados com cimento resinoso (RelyX Ultimate - 3M ESPE), sendo fotopolimerizados por 40 segundos. As raízes foram seccionadas axialmente em discos de 2 mm e os espécimes foram submetidos ao teste de push-out. As médias dos valores obtidos (MPa) foram analisadas por meio dos testes one-way ANOVA e Tukey (α=0,05) e os tipos de falhas analisadas em estereomicroscópio com aumento de 8,0X. Os resultados mostraram que não houve diferença estatisticamente significativa entres os grupos avaliados, assim como quando comparados os terços radiculares em cada grupo (p>0,05), entretanto resultados significantes foram encontrados entre os grupos G1 e G2 na região cervical (p=0,045). Falhas mista e adesiva entre cimento e dentina foram mais prevalentes. Pôde-se concluir que o uso da clorexidina a 2% no conduto radicular pode interferir na resistência de união de pinos de fibra de vidro e que o ácido cítrico não influenciou nos resultados. / The aim of this study was to investigate the influence of root dentine treatment with 2% chlorhexidine and 10% citric acid on bond strength of fiberglass post cemented with self-etching cement. Forty five human single-rooted teeth were selected and sectioned in the cement-enamel junction, standardizing them with 14 mm length. After endodontic treatment the roots were randomly divided in 3 groups (n=15) according to the previous treatment of the root canal: G1, no treatment; G2, application of 2% chlorhexidine (Rioquímica®) for 60s; G3, application of 10% citric acid (Idem per Idem - Farmácia de Manipulação Ltda) for 60s. Subsequently, the self-etching adhesive Single Bond Universal (3M ESPE) was applied in the canals and on the fiberglass post (White Post, FGM) and these ones were cemented with resin cement (RelyX Ultimate - 3M ESPE), and light polymerized for 40s. The roots were sectioned transversely in slides of 2 mm thickness and the push-out test was performed. Data were analyzed by one-way ANOVA and Tukey test (α=0.05) and the types of failures were analyzed under stereomicroscopy (8.0X). The results show that there was no statistically significant difference between the groups, as well as when comparising bond strength in root thirds in each group (p>0.05), however, significant results were found between groups G1 and G2 in the cervical third (p=0.045). Mixed and adhesive failures between cement and dentine were predominant. It can be concluded that the use of 2% chlorhexidine in the root canal can interfere in the fiberglass posts bond strength.
240

Resistência de união de um cimento resinoso a diferentes superfícies de alumina densamente sinterizada / Shear bond strenght of a resin cement to different surfaces of densely sintered alumina

Juan Rommel Medina Valdivia 20 June 2007 (has links)
O propósito deste estudo foi avaliar a resistência adesiva ao cisalhamento de um cimento resinoso à alumina densamente sinterizada testando o tratamento superficial feito pelo fabricante. O cimento utilizado foi o Multilink (Ivoclar Vivadent) e a alumina foi a Procera®Alumina (Nobel Biocare) constituída por 99,9 % de óxido de alumínio densamente sinterizado. Trinta e dois cilindros de alumina foram confeccionados pela Nobel Biocare, onde um dos extremos deste cilindro recebeu o tratamento superficial e o outro não. Para a aplicação do cimento resinoso sobre os cilindros de alumina, utilizou-se uma matriz de Teflon com um orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Foram determinados 4 grupos experimentais: Grupo 1 superfície sem tratamento; Grupo 2 superfície sem tratamento e com aplicação de adesivo; Grupo 3 - superfície com o tratamento realizado pelo fabricante; Grupo 4 superfície com tratamento realizado pelo fabricante e com adesivo. Após a aplicação do cimento nos 4 grupos, os espécimes foram armazenados em água deionizada a 37ºC durante 24h, sendo, em seguida, montados em uma máquina universal de ensaios para realização dos testes de resistência ao cisalhamento. Os resultados foram submetidos à análise de variância a dois critérios e ao teste de Tukey para comparação entre os grupos. A superfície tratada (grupo 3) apresentou valores significativamente maiores que todos os outros grupos. A presença do adesivo diminuiu a resistência adesiva quando aplicado na superfície tratada, mas não deu diferença significante quando aplicado na superfície sem tratamento. / The aim of this study was to investigate the shear bond strength between a resin cement and densely sintered alumina treated by the fabricant. The resin cement used was the Multilink (Ivoclar Vivadent) and the alumina the Procera®Alumina (Nobel Biocare) made with 99,9% of densely sintered aluminum oxide. Thirty two alumina cylinders were made by Nobel Biocare, and in one of the extremes was applied a own`s fabricant surface treatment. For the application of the cement, a Teflon matrix with a central hole (diameter of 3,5 mm and a height of 3,0 mm) was used. Four groups were created: Group 1 surface without treatment; Group 2 - surface without treatment and with adhesive; Group 3 surface with the own`s fabricant treatment; Group 4 - surface with the own`s fabricant treatment with adhesive. After the cement application, the specimens were stored in water at 37º C for 24 hours. Then the samples were placed in a universal testing machine for making the shear strength test. Statistical analysis was performed with two-way analysis of variance (ANOVA), and paired comparisons between groups were done with Tukey`s multiple comparison. Higher significant values were detected for Group 3 when compared with all the other groups. The adhesive decreased the shear bond strength when laid on the treated surface, and there were no difference when laid on the untreated surface.

Page generated in 0.2851 seconds