• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 261
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 265
  • 265
  • 169
  • 160
  • 56
  • 49
  • 48
  • 43
  • 43
  • 41
  • 37
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Avaliação in vitro de propriedades mecânicas, químicas e antimicrobianas de um selante de fossas e fissuras isento de bisfenol A / In vitro evaluation of mechanical, chemical and antimicrobial properties of a bisphenol A-free pit-and-fissure sealant

Aguiar, Soraia Monique Fiorati 21 May 2010 (has links)
Tendo em vista o importante papel desempenhado pelos selantes de fossas e fissuras na prevenção da cárie dental, o objetivo do presente estudo foi avaliar in vitro propriedades mecânicas, químicas e ntimicrobianas do selante isento de bisfenol A Embrace Wetbond™. Para os testes de resistência ao cisalhamento e microinfiltração foram selecionados 135 terceiros molares hígidos, extraídos de humanos, divididos aleatoriamente em 6 grupos: (I) selante Fluroshield® sem contaminação; (II) selante Embrace Wetbond™ sem contaminação; (III) selante Fluroshield® contaminado com saliva; (IV) selante Embrace Wetbond™ contaminado com saliva; (V) selante Fluroshield® contaminado com água; e (VI) selante Embrace Wetbond™ contaminado com água. No estudo de resistência ao cisalhamento os dentes foram seccionados no sentido vestíbulo-lingual, a porção radicular removida e as superfícies mesiais e distais foram embebidas em resina de poliéster. Após o condicionamento do esmalte, foi aplicado o selante com o auxílio de uma matriz de Teflon®. Os espécimes foram termociclados e submetidos ao teste de resistência ao cisalhamento com uma velocidade de 0,5mm/min e célula de carga de 50kgf. Os resultados foram comparados empregando a análise de variância (ANOVA) e pós-teste de Tukey. No estudo de microinfiltração, após o condicionamento do esmalte foi aplicado o selante. Os dentes foram termociclados, selados na região da câmara pulpar com resina composta, isolados, imersos em solução de rodamina B a 0,2%, incluídos em resina acrílica, seccionados, lixados, montados em lâminas, identificados e analisados em microscópio óptico para quantificação da microinfiltração. Os resultados foram comparados empregando o teste de Kruskal-Wallis e o pós-teste de Dunn. No estudo de liberação de fluoreto por meio de água aquecida e saliva artificial foram selecionados dois selantes resinosos contendo fluoreto (Embrace Wetbond™ e Fluroshield®), uma resina composta micro-híbrida (FiltekTM Z-250) e um cimento de ionômero de vidro (Vidrion R). As determinações de fluoreto foram realizadas por potenciometria direta, utilizando o eletrodo seletivo combinado de fluoreto. Para o teste de liberação de fluoreto em saliva artificial foram confeccionados 8 corpos de prova de cada material , os quais foram armazenados em tubos plásticos contendo saliva artificial, substituída diariamente. Após 15 dias, foi avaliada a quantidade de fluoreto liberado nas soluções. Os valores obtidos em mV foram convertidos em ppm (μg/ml). Os resultados foram comparados empregando a análise de variância (ANOVA) e o pós-teste de Tukey. No estudo da atividade antimicrobiana, efetuado por meio do teste de difusão em ágar pelo método do poço, foram selecionados dois selantes resinosos contendo fluoreto (Embrace Wetbond™ e Fluroshield®), um cimento de ionômero de vidro (Vidrion R), solução de digluconato de clorexidina a 1% e soro fisiológico. Foram utilizadas cepas de S. mutans (ATCC 25175 e cepa de campo), na densidade de 1-2 da escala de McFarland. Após o período de incubação, a zona de inibição do crescimento microbiano foi mensurada. Os resultados foram comparados empregando a análise de variância ANOVA e o pós-teste de Bonferroni. O nível de significância em todas as análises estatísticas foi de 5%. No estudo da dosagem de bisfenol A foram selecionados dois selantes resinosos (Embrace Wetbond™ e Fluroshield®), dispensados em recipientes contendo 3ml de metanol. Após homogeneização e filtragem, os extratos foram analisados utilizando um espectrômetro de massas por cromatografia gasosa. Foram realizados testes com as fórmulas moleculares do bisfenol A (C15H16O2) e do Bis-GMA (C29H36O8). Com base nos resultados obtidos pôde-se concluir que o selante Embrace Wetbond™ apresentou resistência ao cisalhamento próxima do mínimo aceitável e alta microinfiltração, quando utilizado de acordo com as indicações do fabricante, em condições de contaminação com umidade. Por outro lado, esse selante apresentou elevada liberação de fluoreto, tanto em água aquecida quanto em saliva artificial, apresentou elevada atividade antimicrobiana e não apresentou liberação de bisfenol A e de Bis- GMA. / Considering the important role of pit-and-fissure sealants on the prevention of dental caries, the purpose of this study was to evaluate in vitro the mechanical, chemical and antimicrobial properties of the bisphenol A-free pit-and-fissure sealant Embrace Wetbond™. For the shear bond strength and microleakage tests, 135 sound human third molars were selected and randomly assigned to 6 groups: (I) Fluroshield® sealant without contamination; (II) sealant Embrace Wetbond™ without contamination; (III) Fluroshield® sealant contaminated with saliva; (IV) Embrace Wetbond™ sealant contaminated with saliva; (V) Fluroshield® sealant contaminated with water; and (VI) Embrace Wetbond™ sealant contaminated with water. For the shear bond strength test, the teeth were sectioned in a buccolingual direction, the root portion was removed and the mesial and distal surfaces were embedded in polyester resin. The sealant was applied to the acid-etched enamel with the aid of Teflon® matrix. The specimens were thermocycled and subjected to a shearing force at a crosshead speed of 0.5mm/min with a 50kgf load cell. Data were analyzed statistically by analysis of variance (ANOVA) and Tukeys post-test. For the microleakage assay, after acid etching of enamel, the teeth were thermocycled, the pulp chamber was sealed with composite resin, and the teeth were rendered waterproof, immersed in 0.2% B rhodamine solution, embedded in acrylic resin, sectioned, ground, mounted on glass slides, identified and analyzed with an optical microscope for quantification of microleakage. The results were compared by the Kruskal-Wallis and Dunns post-test. Two fluoride-containing resin sealants (Embrace Wetbond™ and Fluroshield®), a microhybrid composite resin (FiltekTM Z-250) and a glass ionomer cement (Vidrion R) were selected for the fluoride release test in heated water and artificial saliva. Fluoride measurements were performed with a direct potentiometry using a fluoride ion selective electrode. For the test in saliva artificial, 8 specimens of each material were fabricated and stored in plastic tubes containing artificial saliva, which as daily renewed. The amount of fluoride released in the solutions after 15 days was analyzed, and the the values obtained in mV were converted into PPM (μg/mL). The results were compared by ANOVA and Tukeys post-test. Two fluoride-containing resin sealants (Embrace Wetbond™ and Fluroshield®), a glass ionomer cement (Vidrion R), 1% chlorhexidine digluconate solution and saline were selected for the analysis of the antimicrobial activity using the agar-well diffusion assay. Suspensions of S. mutans strains (ATCC 25175 and field strain) with density equivalent to the 1-2 McFarland scale were used. After incubation, the zones of microbial growth inhibition were measured. The results were compared by ANOVA and Bonferroni post-test. A significance level of 5% was set for all statistical analyses. For the analysis of bisphenol A dosage, two resin sealants (Embrace Wetbond™ and Fluroshield®) were delivered in receptacles containing 3ml of methanol. After homogenization and filtering, the extracts were analyzed under gas chromatography-mass spectroscopy and tests were performed with the molecular formulas of bisphenol A (C15H16O2) and Bis-GMA (C29H36O8). Based on the obtained results, it may be concluded that the sealant Embrace Wetbond™ presented shear bond strength near of the minimum acceptable and great microleakage when used according to the manufacturers instructions under moisture contamination conditions. On the other hand, this sealant presented high fluoride release in both heated water and artificial saliva, showed high activity antimicrobial and did not present release of bisphenol A or Bis-GMA.
202

Avaliação do uso de solos não convencionais em estruturas de solo reforçado / Evaluation of the use of the marginal soils in reinforced soil structures

Patias, Josiele 27 May 2005 (has links)
As estruturas de solo reforçado tornaram-se uma alternativa eficiente para a construção de aterros e muros de contenção. No entanto, o seu uso é limitado pelas especificações técnicas, que recomendam apenas materiais granulares, por apresentarem alta resistência e capacidade de livre drenagem. Todavia, nem sempre se dispõem deste tipo de material nas proximidades das obras, o que pode torná-las onerosas, devido aos custos de transporte. Os solos não convencionais, definidos como solos de granulometria fina (caracterizados como argilas, siltes, e solos areno-siltosos), merecem atenção, pois são encontrados em abundância em muitos locais do nosso território. Casos históricos brasileiros de obras instrumentadas revelam a eficiência destes materiais na composição de aterros de estruturas de solo reforçado, devido ao bom desempenho técnico ao longo de sua vida útil. Acredita-se que o uso de inclusões permeáveis possa contribuir na aceleração da drenagem da água das camadas de maciços construídos com solos finos, permitindo a dissipação mais rápida do excesso de pressões neutras. Para elucidar estas questões foram realizados ensaios de compressão triaxial rápidos (UU) e adensados rápidos (CU), com o intuito de avaliar o desempenho de solos não convencionais reforçados com inclusões permeáveis e impermeáveis. Utilizaram-se como reforços papel alumínio (reforço inextensível e impermeável) e geotêxtil (reforço extensível e permeável), o que permitiu comparações dos resultados obtidos dos ensaios com corpos de prova reforçados com os obtidos de corpos de prova não reforçados. Os solos utilizados foram duas argilas silto-arenosas, uma de comportamento laterítico e a outra não laterítico e uma areia fina com aproximadamente 40% de finos (material com diâmetro inferior à peneira 200), com comportamento não laterítico. Verificou-se que a combinação de solos finos com reforços permeáveis resultou num ganho de resistência ora em termos de ângulo de atrito interno, ora em relação à coesão, apenas a areia fina obteve ganho de resistência ao ser reforçada com o papel alumínio. Observou-se que a argila silto-arenosa, com comportamento laterítico, e a areia fina apresentaram uma interação mais eficiente com os reforços de geotêxtil. Constatou-se ainda que os reforços permeáveis promoveram a drenagem da água dos corpos de prova / The reinforced soil structures became an efficient alternative for the construction of embankments and retaining walls. However, the use of these structures are limited by design specifications which recommend the use of granular materials that present high shearing strength and free drainage capacity. Some granular soils are not always available in the proximities of works, in these cases, costs of transportation can be high. The marginal soils, defined as fine grain-size (characterized as clays, silts, and sandy-silty) soils, deserve attention because they are found in abundance in many places on our territory, besides that, brazilian historical cases of instrumented structures have shown their efficiency when used as backfill of reinforced soil structures. It is also believed that the use of permeable inclusions can contribute to the acceleration of water drainage, which allows faster dissipation of pore pressure. To contribute to the understanding of these aspects of reinforced soil behavior, triaxial compression tests, unconsolidated-undrained (UU) and consolidated-undrained (CU), were carried out in order to check the performance of reinforced marginal soil when reinforced with permeable and impermeable inclusions. Aluminum foil (inextensible and impermeable reinforcement) and geotextile (extensible and permeable reinforcement) were used as reinforcement, allowing the comparison of results of tests using reinforced and non-reinforced samples. The soils used were two sandy silty clays - a lateritic and a non-lateritic soil - and fine sand with 40% of fines, presenting non-lateritic behavior. It was verified that the combination of cohesive soil and permeable reinforcements resulted on an increase of resistance parameters, angle of internal friction and cohesion. It was observed that the lateritic sandy silty clay and the fine sand presented more efficient interaction with the geotextile reinforcements. Also, it was verified that the permeable reinforcements promoted faster water drainage
203

Resistência de união de um cimento resinoso a diferentes superfícies de alumina densamente sinterizada / Shear bond strenght of a resin cement to different surfaces of densely sintered alumina

Valdivia, Juan Rommel Medina 20 June 2007 (has links)
O propósito deste estudo foi avaliar a resistência adesiva ao cisalhamento de um cimento resinoso à alumina densamente sinterizada testando o tratamento superficial feito pelo fabricante. O cimento utilizado foi o Multilink (Ivoclar Vivadent) e a alumina foi a Procera®Alumina (Nobel Biocare) constituída por 99,9 % de óxido de alumínio densamente sinterizado. Trinta e dois cilindros de alumina foram confeccionados pela Nobel Biocare, onde um dos extremos deste cilindro recebeu o tratamento superficial e o outro não. Para a aplicação do cimento resinoso sobre os cilindros de alumina, utilizou-se uma matriz de Teflon com um orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Foram determinados 4 grupos experimentais: Grupo 1 superfície sem tratamento; Grupo 2 superfície sem tratamento e com aplicação de adesivo; Grupo 3 - superfície com o tratamento realizado pelo fabricante; Grupo 4 superfície com tratamento realizado pelo fabricante e com adesivo. Após a aplicação do cimento nos 4 grupos, os espécimes foram armazenados em água deionizada a 37ºC durante 24h, sendo, em seguida, montados em uma máquina universal de ensaios para realização dos testes de resistência ao cisalhamento. Os resultados foram submetidos à análise de variância a dois critérios e ao teste de Tukey para comparação entre os grupos. A superfície tratada (grupo 3) apresentou valores significativamente maiores que todos os outros grupos. A presença do adesivo diminuiu a resistência adesiva quando aplicado na superfície tratada, mas não deu diferença significante quando aplicado na superfície sem tratamento. / The aim of this study was to investigate the shear bond strength between a resin cement and densely sintered alumina treated by the fabricant. The resin cement used was the Multilink (Ivoclar Vivadent) and the alumina the Procera®Alumina (Nobel Biocare) made with 99,9% of densely sintered aluminum oxide. Thirty two alumina cylinders were made by Nobel Biocare, and in one of the extremes was applied a own`s fabricant surface treatment. For the application of the cement, a Teflon matrix with a central hole (diameter of 3,5 mm and a height of 3,0 mm) was used. Four groups were created: Group 1 surface without treatment; Group 2 - surface without treatment and with adhesive; Group 3 surface with the own`s fabricant treatment; Group 4 - surface with the own`s fabricant treatment with adhesive. After the cement application, the specimens were stored in water at 37º C for 24 hours. Then the samples were placed in a universal testing machine for making the shear strength test. Statistical analysis was performed with two-way analysis of variance (ANOVA), and paired comparisons between groups were done with Tukey`s multiple comparison. Higher significant values were detected for Group 3 when compared with all the other groups. The adhesive decreased the shear bond strength when laid on the treated surface, and there were no difference when laid on the untreated surface.
204

Comportamento mecânico de resíduos sólidos urbanos / Mechanical behavior of urban solid waste

Carvalho, Miriam de Fátima 27 October 1999 (has links)
Nesta tese estuda-se o comportamento mecânico de resíduos sólidos urbanos provenientes do aterro sanitário Bandeirantes (SP - Brasil) por meio de ensaios de campo e de laboratório, bem como, através de dados de monitoramento de recalques in situ. Os dados são analisados e algumas conclusões a respeito do comportamento do resíduo sólido urbano são apresentadas. Resultados de ensaios de campo, tais como, sondagens de simples reconhecimento com medida de SPT (Standard Penetration Test), ensaios penetrométricos tipo CPT (Cone Penetration Test), ensaios de infiltração, sondagens a trado para coleta de amostras, ensaio cross-hole e ensaio de resistividade elétrica são apresentados e discutidos, enfatizando as dificuldades de execução e a faixa de valores obtidos. Os ensaios de laboratório foram executados em amostras remoldadas, coletadas em dois furos de trado (40 cm de diâmetro), até cerca de 30 m de profundidade. O resíduo tem cerca de 15 anos de aterrado e os ensaios físicos e químicos executados mostraram que este é composto de cerca de 50% de uma fração pastosa com baixos valores de DQO (demanda química de oxigênio) e STV (sólidos totais voláteis), os quais demonstram que o resíduo já atingiu um avançado grau de decomposição. A resistência ao cisalhamento do resíduo foi avaliada a partir de ensaios triaxiais não drenados (CU) e drenados (CD), utilizando corpos de prova saturados e não saturados de grandes dimensões (15 x 30 cm e 20 x 40 cm). Desses ensaios obteve-se que os parâmetros de resistência ao cisalhamento do resíduo sólido urbano são largamente dependentes da deformação da amostra, e não foi observado nenhum pico ou valor último nas curvas tensão-deformação. Os valores obtidos estão de acordo com alguns resultados disponíveis na literatura para ensaios de laboratório e retro-análise. Os ensaios de compressão confinada, executados num consolidômetro de grande diâmetro (385 mm), mostraram uma rápida compressão inicial e primária e uma grande compressão secundária. As medidas de campo também mostraram deformações dessa natureza, as quais podem ser divididas em duas etapas: a primeira, relacionada à fase inicial do aterro e a segunda, associada, principalmente, à degradação química e biológica do resíduo. / This thesis deals with the mechanical behavior of urban solid waste from Bandeirantes sanitary landfill (São Paulo, Brazil). Field and laboratory tests, as well as data from field instrumentation (settlement) were obtained and used in the analysis. Results of in situ tests such as standard penetration test (SPT), cone penetration test (CPT), infiltration tests, auger boring for sampling, cross-hole test and electric resistivity are presented and discussed focusing on the difficulties in performing them as well as their potential as a source of design parameters. Laboratory tests were performed using remolded samples collected in two boreholes about 30 m in depth. The waste is about 15 years old and physical and chemical tests showed that about 50% of it is composed of organic past with low values of COD and TDS, which denote that it is degraded to a large extent. Shear strength of waste was studied by means of consolidated-drained (CD) and consolidated-undrained (CU) triaxial compression tests on large specimens, tested both at natural water content and saturated. It is shown that shear strength properties are largely dependent on deformation, since no peak or ultimate value was achieved on stress-strain curves. The values obtained are in accordance with some of the few results available in the literature, either from laboratory and back analysis. Confined compression tests carried out on large samples (385 mm diameter) showed quick initial and primary consolidation and large secondary compression. This in accordance with the field behavior, although in this case secondary compression seems to be composed of two parts: the first, related to the early stages of the fill and second one, which seems to be commanded mainly by chemical and biological degradation.
205

Adesão de diferentes sistemas adesivos ao esmalte e à dentina de dentes decíduos submetidos à radioterapia / Adhesion of different adhesive systems to the enamel and dentin of primary teeth that have undergone radiotherapy

Mellara, Talitha de Siqueira 06 December 2016 (has links)
A radioterapia (RT), quando aplicada na região de cabeça e pescoço, pode ocasionar alterações estruturais no esmalte e na dentina que poderiam influenciar o comportamento dos sistemas adesivos. O presente estudo teve como objetivo avaliar a influência da RT na adesão dos sistemas adesivos (Clearfil SE Bond e Adper&trade; Single Bond 2) ao esmalte (E) e à dentina (D) de dentes decíduos, em diferentes tempos (antes e após a RT). Foram utilizados 60 molares decíduos seccionados obtendo um total de 120 fragmentos de esmalte e 120 de dentina que, após o preparo da superfície, foram divididos aleatoriamente em 4 grupos (n=30/grupo): G1 (controle) - esmalte/dentina sem irradiação + procedimento restaurador; G2 - procedimento restaurador realizado antes da RT, G3 - procedimento restaurador realizado após a RT; e G4 - procedimento restaurador realizado 6 meses após a RT. Cada um dos grupos foi dividido em 2 subgrupos, sendo no subgrupo A empregado o sistema adesivo etch-rinse Adper&trade; Single Bond 2; e no subgrupo B o adesivo self-etch Clearfil SE Bond. Os espécimes foram irradiados com fração de dose de 2 Gy, por 5 dias consecutivos, até atingir a dose total de 60 Gy, com um total de 30 frações, durante 6 semanas. O procedimento restaurador foi realizado com resina Z350, e para padronização da restauração foi utilizada uma matriz, de forma que os espécimes apresentasse 4 mm de altura e 2 mm de diâmetro. Os corpos de prova foram submetidos ao teste de resistência ao cisalhamento (célula de carga 50 kgf e velocidade 0,5 mm/minuto) obtendo-se o resultado em N, o qual foi transformado em MPa. A análise do padrão de fratura foi realizada em microscopia confocal (MC). Foram selecionados 5 espécimes de esmalte e 5 espécimes de dentina, para realização da análise morfológica da superfície dental por meio de microscopia confocal, sendo estes avaliados a cada 10 Gy. Para a análise da interface adesiva foram selecionados 3 espécimes de cada grupo e estes foram preparados para análise em microscopia eletrônica de varredura (MEV). O esmalte e a dentina foram analisados separadamente, sendo os dados analisados por ANOVA a 2 critérios e pós- teste de tukey (p<0,05). O nível de significância adotado foi 5%. Pode-se observar que, para ambos os substratos, o Clearfil SE Bond (E: 20,19 MPa; D: 17,61 MPa) apresentou adesão estatisticamente superior ao Single Bond (E: 17,21 MPa; D: 15,45 MPa) (p<0,05). Quanto ao momento da realização da restauração, tanto no esmalte quanto na dentina, o grupo 2 apresentou os menores valores. Na comparação fator irradiação observou-se que a irradiação afetou negativamente a adesão do esmalte e da dentina (p<0,05), no entanto no grupo 4 não observou-se alteração (p>0,05). O tipo de fratura predominante foi adesiva, que aumentou a predominância com a irradiação. Na análise em MC houve alterações morfológicas em esmalte e dentina após a dose cumulativa de 40 Gy. Em MEV observou-se a alterações na formação de tags e de camada híbrida. Pôde-se concluir que a radioterapia alterou a morfologia da superfície do esmalte e da dentina, e afetou a adesão dos sistemas adesivos, sendo necessário esperar pelo menos 6 meses para a realização dos procedimentos restauradores, tendo o sistema Clearfil SE Bond menos influenciado. / When radiotherapy (RT) is performed in the head and neck region, it could lead to structural alteration in enamel and dentin that could influence the behavior of the bonding agents. The present study aimed to evaluate whether the RT interferes in the bonding o two adhesive systems (Clearfil SE Bond e AdperTM Single Bond 2) to enamel (E) and dentin (D) of primary teeth, in different times (before and after RT). Sixty primary molars were cut in a total of 120 fragments of enamel and 120 of dentin, which after the surface polishing were randomly divided into 4 groups (n=30/group): G1 (control) - enamel and dentin without RT + restorative procedures; G2 - restorative procedures performed before RT; G3 - restorative procedures performed after RT; and G4 - restorative procedures performed 6 months after RT. Each one of the groups was then divided into 2 subgroups: subgroup A using the etch-rinse Adper&trade; Single Bond 2; and subgroup B using the self-etch Clearfil SE Bond. The specimens were irradiated in dose fractions of 2 Gy, for 5 consecutive days, until reaching the final dose of 60Gy, in a total of 30 fractions, during 6 weeks. The restorative procedures were done using the Z350 composite, and for standardization of the restorations a matrix was used, so the specimens all presented 4 mm height and 2 mm of diameter. The specimens were submitted to the shear bond strength test (load of 50 kgf and speed of 0.5 mm/minute), the result was obtained in N and then transformed to Mpa. The fracture pattern was analyzed in a confocal microscopy (MC). Five specimens of enamel and 5 of dentin were chosen to the morphological analyzes also by MC, those specimens were evaluated every 10 Gy. As for the bonding interface 3 specimens of each group were chosen, and prepared for scanning electron microscopy (SEM). Enamel and dentin were evaluated separately, data was analyzed by the ANOVA and Post Test Tukey (p<0.05). Significance level was 5%. It could be observed that for both substrates the Clearfil SE Bond (E: 20.19 MPa; D: 17.61 MPa) was statically superior than Single Bond (E: 17.21 MPa; D: 15.45 MPa) (p<0.05). As for the time of restoration, group 2 had the worst results, in both enamel and dentin. It was observed that that radiation affected negatively the bonding in enamel and dentin (p<0.05), however, in the group 4 no alterations were observed (p<0.05). The predominant fracture pattern was the adhesive, which had raised its prevalence according to the radiation. In the MC analyses there were morphological alteration in enamel and dentin after the cumulative doses of 40 Gy. It was observed, by SEM, tags formations and alterations on the hybrid layer. It could be concluded that RT had affected the morphological surface of enamel and dentin, and that it affected the adhesion of the bonding systems, indicating that it should be waited at least 6 months after RT to perform restorative procedures, in which the Clearfil SE Bond was less affected.
206

Comportamento anisotrópico de um solo laterítico compactado / Anisotropic behavior of a compacted laterite soil

Santos, Roberto Aguiar dos 04 December 2015 (has links)
A compactação de aterros pode gerar comportamento anisotrópico, a depender do teor de umidade de compactação, entre outros fatores. O principal objetivo deste estudo foi investigar alguns aspectos relacionados à anisotropia inerente induzida pela compactação de um solo laterítico. Após realizar a caracterização mineralógica, geotécnica e microestrutural deste solo, estudou-se a resistência ao cisalhamento, condutividade hidráulica, compressibilidade e deformabilidade. O solo estudado foi classificado como laterítico arenoso (LA\') e apresentou agregação relativa da ordem de 12%. A metodologia desenvolvida no intuito de corrigir o aumento na massa específica seca das camadas inferiores, causado pelo processo de compactação, mostrou-se eficaz. A partir da curva de compactação foram consideradas amostras representativas das três condições de umidade de compactação: ramo seco, umidade ótima e ramo úmido. Corpos de prova foram talhados paralelamente e ortogonalmente às camadas de compactação. Os ensaios de porosimetria revelaram um comportamento bimodal na distribuição do tamanho de poros e também que o teor de umidade de compactação não interferiu no tamanho dos microporos. Para o solo compactado no ramo seco e na umidade ótima, a resistência ao cisalhamento correspondente à direção ortogonal se mostrou superior àquela correspondente à direção paralela às camadas de compactação. Por outro lado, a resistência ao cisalhamento no ramo úmido mostrou-se praticamente independente da direção de talhagem dos corpos de prova. Este comportamento se deve à maior capacidade do solo, em um dado teor de umidade, em absorver a energia aplicada e distribuí-la na direção paralela e ortogonal. Com relação às propriedades elásticas do material, observou-se que o aumento do teor de umidade de compactação contribui para redução da anisotropia de deformabilidade. Dentre as propriedades investigadas, a anisotropia de condutividade hidráulica das amostras correspondente ao ramo úmido foi a mais pronunciada, exibindo fluxo oito vezes maior na direção vertical que na horizontal. Finalmente, as discussões e análises presentadas nesta pesquisa mostraram que o grau de anisotropia depende diretamente do teor de umidade de compactação e que diminui com incremento das tensões aplicadas no solo. / Compacted embankments can have anisotropic behavior, depending on several factors, including the compaction water content. The aim of this study was to investigate some aspects regarding the inherent anisotropy of a lateritic soil, caused by the compaction process. After performing the geotechnical, mineralogical and microstructural characterization, properties of shear strength, hydraulic conductivity, compressibility and deformability were investigated. This soil this soil was classified as lateritic sand. The grainsize distribution curve indicates 12% the fine particle aggregation. The methodology developed in order to correct the increase in dry density of the lower layers, generated by the compression process, was effective. From the compaction curve, representative samples corresponding to the three compaction water content conditions, representing the dry side, the optimal water content and the wet side were considered. Specimens were trimmed parallel and orthogonally to the compaction layers. The porosimetry tests showed a bimodal behavior in the pore size distribution and also that the compaction water content did not influence the size of the micropores. For the compacted soil sample corresponding to the dry side and optimum water content, the shear strength corresponding to the orthogonal direction was higher than that corresponding to the parallel direction to the compaction layers. However, they were almost equal for both the orthogonal and the parallel directions to the compaction layers. This behavior is due to the higher capacity of the soil at a given moisture content, to absorb the energy applied and distribute it in parallel and orthogonal direction. The analysis the values of maximum shear modulus of the material showed that increasing compaction water content reduces the anisotropy degree. Among the investigated properties, the hydraulic conductivity anisotropy of the samples corresponding to the wet branch was the most pronounced, showing permeability eight times higher in the vertical direction than that in the horizontal direction. Finally, the discussions and analyzes presented in this study showed that the degree of anisotropy directly depends on the compaction water content and decreases with increase confining stress applied to the soil specimens.
207

Avaliação da condutividade hidráulica e da resistência ao cisalhamento de misturas solo-bentonita: estudo de caso de um aterro sanitário localizado em Rio Grande (RS) / Evaluation of hydraulic conductivity and shear strength of soil-bentonite mixtures: a case study of a landfill located in Rio Grande (RS)

Camargo, Karina Retzlaff 15 October 2012 (has links)
A utilização do solo natural compactado com bentonita empregado em camadas impermeáveis para retenção de contaminantes é bastante usual para aterros sanitários. Neste trabalho são apresentados resultados de ensaios condutividade hidráulica e de resistência ao cisalhamento, realizados em equipamentos triaxiais. Além do solo natural, foram utilizadas misturas solo-bentonita nos teores de 2%, 4% e 6%. O solo arenoso ensaiado é encontrado na Planície Costeira Sul do Estado do Rio Grande do Sul. Os valores de condutividade hidráulica diminuiram tanto com o acréscimo do teor de bentonita, quanto com o aumento da tensão de confinamento. A condutividade hidráulica do solo apresentou uma redução de três ordens de grandeza quando este foi compactado com 6% de bentonita (de \'10 POT.-7\' para \'10 POT.-10\' m/s). Em relação a resistência ao cisalhamento do material, constatou-se que com o acréscimo do teor bentonita de 0 para 6%, a coesão efetiva aumentou (de 2,3 para 12,8 kPa) e o ângulo de atrito efetivo diminuiu (de 22,7º pra 14,0º). / Compacted soil-bentonite mixtures used as impermeable layers for retention of contaminants is quite usual in landfills. This paper presents the results of hydraulic conductivity and shear strength tests conducted in a triaxial apparatus. Natural soil, and soil-bentonite mixtures at 2%, 4% and 6% concentrations were tested. The sandy soil tested is found in the Southern Coastal Plain of Rio Grande do Sul. The hydraulic conductivity decreased with both the increase of bentonite content and increase of confining stress. Compared to natural soil, the hydraulic conductivity of compacted soil-bentonite mixtures at 6% content decreased by three orders of magnitude (from \'10 POT.-7\' to \'10 POT.-10\' m/s). Regarding the material shear strength, it was found that when the natural soil is compared to compacted soil-bentonite mixtures at 6% content, the effective cohesion increased (from 2.3 to 12.8 kPa) and the effective friction angle decreased (from 22. 7º to 14.0º).
208

Deformabilidade de um solo laterítico não saturado / Stiffness and strength of a lateritic unsaturated soil

Georgetti, Giovana Bizão 21 November 2014 (has links)
A deformabilidade é uma propriedade fundamental em projetos geotécnicos. A constatação de que as deformações em várias obras de engenharia se situam na faixa de pequenas e muito pequenas deformações e as limitações das técnicas de ensaio em medir tal nível de deformações levaram ao desenvolvimento de técnicas com base em solicitações dinâmicas, dentre as quais, as de coluna ressonante e bender elements. Particularmente, o emprego da técnica de bender elements tem crescido devido à simplicidade de execução dos ensaios, e determinação do módulo de cisalhamento máximo dos solos. Diversos estudos acerca das propriedades deformacionais dos solos determinadas por este método têm sido conduzidos em solos saturados ou secos, não obstante, estudos desta natureza em solos não saturados ainda são relativamente escassos. Esta pesquisa investigou a influência de algumas variáveis, como a sucção e a tensão confinante sobre a deformabilidade de um solo laterítico não saturado típico do interior do Estado de São Paulo, empregando bender elements, coluna ressonante e compressão triaxial com instrumentação interna. Além disso, buscando uma caracterização mais completa deste solo, ensaios de compressão triaxial foram realizados para quantificar sua resistência ao cisalhamento. Os resultados destes ensaios sugeriram a ocorrência de encruamento em solo indeformado, e uma envoltória planar de resistência foi usada para representar a resistência ao cisalhamento da amostra compactada. Já no que se refere à deformabilidade, os resultados indicaram que a redução do teor de umidade de compactação, o aumento do confinamento isotrópico ou da sucção são responsáveis por um solo menos deformável. Dados dos ensaios com bender elements foram bem representados por uma função potencial quando o módulo de cisalhamento máximo e a sucção foram normalizados pela tensão confinante líquida. Para o solo compactado não saturado, também ensaiado em coluna ressonante, dados obtidos por ambas as técnicas foram comparados, notando-se velocidades de ondas de cisalhamento um pouco superiores para os ensaios com bender elements, que foram atribuídas às mais altas frequências nestes ensaios. / Stiffness is a fundamental property in geotechnical design. The fact that strains are in the smallto- very small strain range in several engineering works and the limitations of testing techniques in measuring such level of strains led to the development of dynamic techniques, such as resonant column and bender elements. Specifically, the bender elements technique has been increasingly used due to the simplicity in performing tests and computing the maximum shear modulus of the soil. Several studies have been carried out to assess stiffness properties of dry or saturated soils via bender elements, however, studies of this nature are still relatively scarce in unsaturated soils. This research investigated the influence of some variables, like suction and confining stress, on the stiffness of a lateritic unsaturated soil, typical of São Paulo State, via bender elements, resonant column and triaxial compression tests with local gauges. Furthermore, aiming at a more complete characterization of this soil, triaxial compression tests were performed in order to quantify its shear strength. Results from these tests suggested the occurrence of strain hardening on undisturbed specimens, and a planar shear strength envelope was used to represent the compacted sample data. Regarding soil stiffness, results indicated that it increases with a reduction in the compaction moisture content or an increase in isotropic confining stress or suction. Data from bender elements tests were nicely represented by a power function when maximum shear modulus and suction were normalized by the net confining stress. Results of unsaturated compacted soil obtained from bender elements and resonant column tests were compared and slightly larger shear wave velocities were noticed in bender elements tests, which were attributed to the larger testing frequencies used in these tests.
209

Resistência ao cisalhamento de selante associado a dois sistemas adesivos, após contaminação salivar: influência da fotopolimerização individual e simultânea / Shear bond strength of a pit-and-fissure sealant associated with two adhesive systems after salivary contamination: influence of individual and simultaneous light curing

Silva, Jaciara Miranda Gomes da 06 August 2007 (has links)
Este trabalho teve por objetivo avaliar \"in vitro\" a resistência ao cisalhamento de um selante resinoso (Fluroshield - F) em associação com um sistema adesivo total-etch (Adper Single Bond 2-SB) e um self-etching (Clearfil S3 Bond-S3) em condições de contaminação salivar, comparando dois protocolos de fotopolimerização: individual do sistema adesivo e, em seguida, do selante ou simultânea de ambos materiais conjuntamente. Superfícies mesiais e distais de 45 terceiros molares humanos hígidos foram incluídas e planificadas, o sítio de adesão delimitado (Ø 3mm) e os corpos-de-prova alocados aleatoriamente em 6 grupos experimentais (n=15), de acordo com o tratamento empregado: I- F aplicado sobre o esmalte condicionado com ácido fosfórico a 37% (controle). Os demais grupos foram contaminados com saliva (0,01ml por 10 s) e a seguir foram aplicados: II- SB e F fotopolimerizados separadamente; III- SB e F fotopolimerizados conjuntamente; IVS3 e F fotopolimerizados separadamente; V- S3 e F fotopolimerizados simultaneamente; VI- F aplicado sem associação com adesivos sobre o esmalte condicionado e contaminado. A seguir, um cilindro de selante foi confeccionado com o auxílio de uma mesa metálica e de matriz de teflon bipartida sobre o sítio de adesão. Após armazenamento durante 24 horas a 37°C em água destilada, os espécimes foram submetidos ao teste de resistência ao cisalhamento em Máquina de Ensaios Universal (0,5mm/min; 50Kgf). As interfaces adesivas foram analisadas quanto ao tipo de fratura em microscópio óptico com 20x de aumento e para análise qualitativa, três espécimes de cada grupo, foram selecionados e analisados em microscópio eletrônico de varredura. As médias obtidas, em MPa, e os desvios padrão foram: I-12,28 (±4,29); II-8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V- 11,45 (±3,77); e VI-7,47 (±1,99). A análise estatística, por meio da Análise de Variância e teste de Fisher, demonstrou que a contaminação salivar afetou negativamente a resistência adesiva. A associação do sistema adesivo self-etching ao selante resultou em uma média semelhante estatisticamente ao grupo controle. Comparando os protocolos de fotopolimerização, não houve diferença estatisticamente significante entre os grupos nos quais foi realizada a fotopolimerização simultânea ou individual dos materiais. Com base nestes resultados pôde-se concluir que o protocolo de fotopolimerização não afetou os valores de resistência adesiva ao esmalte condicionado e contaminado. A associação do sistema adesivo self-etching Clearfil S3 Bond ao selante Fluroshield aumentou a resistência ao cisalhamento com diferença estastísticamente significante em relação aos grupos nos quais foi utilizado o sistema adesivo Adper Single Bond 2 e com valor médio semelhante ao grupo controle, no qual o selante foi aplicado em condições ideais, na ausência de contaminação salivar. / The purpose of this study was to evaluate in vitro the shear bond strength of a resin-based pit-and-fissure sealant (Fluroshield - F) associated with a total-etch (Adper Single Bond 2 - SB) and a self-etching adhesive system (Clearfil S3 Bond - S3) under conditions of salivary contamination, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal surfaces from 45 sound third molars were embedded, flattened and a 3-mm-diameter bonding site was demarcated. The specimens were randomly assigned to 6 experimental groups (n=15), according to the bonding technique: I - F was applied to the enamel etched with 37% phosphoric acid. The other groups were contaminated with saliva (0.01 mL during 10 s). II - SB and F were light cured separately; III - SB and F were light cured together; IV - 3S and F were light cured separately; V - 3S and F were light cured simultaneously; VI - F was applied to salivary-contaminated etched enamel without an intermediate bonding agent layer. Thereafter, a sealant cylinder was fabricated using a metallic clamping device and a split Teflon matrix placed over the bonding site. After 24-hour storage in distilled water at 37°C, shear bond strength was measured using a knifeedge blade in a universal testing machine (0.5 mm/mm; 50 kgf). The debonded interfaces were examined with an optical microscope to determine the failure modes. For a qualitative analysis, 3 specimens from each group were selected and observed under scanning electron microscopy. Means (±SD) in MPa were: I-12,28 (±4,29); II 8,57 (±3,19); III-7,97 (±2,16); IV-12,56 (±3,11); V-11,45 (±3,77); and VI-7,47 (±1,99). Statistical analysis by ANOVA and Fisher\'s test showed that salivary contamination affected negatively the bond strength. The association between the self-etching adhesive system and sealant yielded bond strength mean statistically similar to that of the control group. Comparing the curing protocols, there was no statistically significant difference between the groups with simultaneous or individual light curing of the materials. Based on these results, it may be concluded that the curing protocol did not affect the bond strength to the contaminated etched enamel. The association of Clearfil S3 Bond self-etching adhesive system to Fluroshield sealant increased the shear bond strength with statistically significant difference from the groups with Adper Single Bond 2 adhesive system, and showing mean value similar to that of the control group, in which the sealant was applied under ideal conditions, without salivary contamination.
210

Estudos de solos tropicais para uso em pavimentação a partir de ensaios triaxiais estáticos / Study of tropical soils for use in pavement through static compression test

Dias, Idalíria de Moraes 08 August 2007 (has links)
O presente trabalho discute comparativamente o comportamento mecânico de solos lateríticos e não lateríticos para uso em pavimentação. Para tanto foram ensaiados 3 pares de solos, sendo cada par constituído por solos de curvas granulométricas semelhantes, mesma classificação HRB e comportamentos distintos quanto à laterização. Foram realizados ensaios triaxiais convencionais do tipo CD saturado e não saturado sem controle de sucção e ensaios de compressão simples. A partir dos resultados dos ensaios foram modeladas as deformações elásticas em função das tensões de confinamento e determinadas as envoltórias de ruptura de Mohr-Coulomb. Concluiu-se que a maior resistência dos solos lateríticos está representada na componente coesão da envoltória de Mohr-Coulomb e que esta é mobilizada praticamente ao máximo desde o início em um ensaio triaxial. A diferença de resistência entre os ensaios saturados e não saturados também se mostrou na coesão, com a soma nesta da componente coesão aparente, fruto da sucção. O ângulo de atrito mostrou-se constante para as duas gêneses, tanto para a condição saturada como para a condição não saturada. Os solos lateríticos apresentam rigidez maior que os não lateríticos, tanto na condição saturada como na condição não saturada. Para os níveis de tensão de confinamento utilizados, a rigidez dos solos, de ambas as gêneses, na condição saturada, diminui com o aumento da tensão confinante. Também se observou que a ação da sucção existente nos ensaios não saturados proporciona, para ambas as gêneses, uma mudança da sensibilidade da rigidez ao aumento da tensão confinante. / The present paper discusses the mechanical behavior of lateritic and no-lateritic soils for use in pavement. To attain that goal, 3 pair soils were rehearsed, being each pair constituted by soils of similar granulometric curves, same HRB classification and different genesis. The experimental program was constituted of static triaxial compression test of the type saturated CD and of the type unsaturated without suction control and unconfined compression strength test. With the results of the tests, the elastic strains were modeled in function of the confinement stresses and the rupture paths of Mohr-Coulomb were determined. The analysis that the shear strength of the lateritic soils is greater than no-lateritic soil because of the cohesion. Since the begin it, the cohesion is mobilized practically to the maximum for both soils. The difference of shear strength between the saturated and unsaturated tests it is also cohesion, with the sum in that component of the cohesion apparent produced for suction. The angle of internal friction is constant for the two genesis as much for the saturated test as for the unsaturated test. The lateritic soils present greater stiffness than the no-lateritic soils, as much for saturated test as for unsaturated test. For the levels of confinement stresses used, in the saturated condition the stiffness of the soils decreases with the increase of the confinement stresses of both genesis. In addition, it was observed that the suction existent in the unsaturated testing produce a change of the sensibility of the soils stiffness to the increase of the confinement stress for both genesis.

Page generated in 0.0861 seconds