• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 261
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 265
  • 265
  • 265
  • 169
  • 160
  • 56
  • 49
  • 48
  • 43
  • 43
  • 41
  • 37
  • 31
  • 30
  • 29
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Efeito de tratamento de superfície na composição de zircônia e na resistência de união com diferentes cimentos /

Sciasci, Plínio. January 2013 (has links)
Orientador: Renata Garcia Fonseca / Coorientador: Felipe de Oliveira Abi-Rached / Banca: Gelson Luís Adabo / Banca: Paulo Henrique dos Santos / Resumo: A zircônia tetragonal policristalina estabilizada por ítria (Y-ZTP), em virtude de suas propriedades mecânicas, pode ser indicada para restaurações dento ou implantosuportadas. Porém, em função de sua composição, este material apresenta dificuldade de se unir eficazmente com os cimentos, comprometendo assim a longevidade das restaurações. O objetivo desse estudo foi avaliar a influência de diferentes tratamentos de superfície e cimentos na resistência ao cisalhamento (RC) de uma Y-ZTP, assim como a caracterização química da superfície da zircônia após os jateamentos. Duzentos e quarenta discos de Y-ZTP (5 x 2 mm) foram obtidos e aleatoriamente divididos em 5 grupos (n=40) de acordo com os tratamentos de superfície: 1) jateamento com óxido de alumínio (Al2O3) de 50 μm + silano; 2) jateamento com Al2O3 de 120 μm + silano; 3) jateamento com partículas de Al2O3 modificadas por sílica (Rocatec Soft) (30 μm) + silano; 4) jateamento com Al2O3 de 120 μm seguido do jateamento com partículas de Al2O3 modificadas por sílica (110 μm) (Rocatec Plus) e 5) Rocatec Plus + silano. Discos de resina composta (Filtek Z350 XT) foram confeccionados e imediatamente cimentados sobre a superfície da zircônia com os seguintes cimentos (n=12): 1) RelyX Luting 2; 2) RelyX ARC; 3) RelyX U100; e 4) Panavia F 2.0. Os silanos usados foram: 1) RelyX Ceramic Primer para os cimentos RelyX Luting 2, RelyX ARC e RelyX U100 e 2) Clearfil SE Bond Primer/Clearfil Porcelain Bond Activator para o cimento Panavia F 2.0. Após a cimentação, os espécimes foram armazenados por 6 dias em meio seco à 37ºC antes da ciclagem térmica (10.000 ciclos, 5 - 55ºC, 30 s/banho) para então serem submetidas ao teste de RC em máquina universal de ensaios (EMIC DL2000). Os dados foram analisados por meio de ANOVA 2 fatores e teste de Tukey ( =0,05)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Due to their excellent mechanical properties, biocompatibility, low thermal conductivity, and chemical stability, Y-TZP (yttria-stabilized tetragonal zirconia polycrystal) ceramics have been used to manufacture metal-free tooth- or implantsupported prostheses. However, the conventional surface treatments (hydrofluoric acid etching and silanization) used for silica ceramics are not effective in promoting suitable bonding between resin-based materials and zirconia. Therefore, the purpose of this in vitro study was to evaluate the effect of different surface treatments on the shear bond strength (SBS) of luting cements to yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) and on its surface chemical characterization. Two hundred and forty Y-TZP discs (5 × 2 mm) were obtained and randomly divided into 5 airborneparticle abraded groups (n=48): 1) 50 μm Al2O3 particles; 2) 120 μm Al2O3 particles; 3) 30 μm silica-modified Al2O3 particles (Rocatec Soft); 4) 120 μm Al2O3 particles, followed by 110 μm silica-modified Al2O3 particles (Rocatec Plus); and 5) Rocatec Plus. After airborne-particle abrasion the surfaces were treated with silane coupling agent. Composite resin discs (Filtek Z350 XT) were produced and bonded immediately to the zirconia-treated surfaces (n=12) with: 1) RelyX Luting 2; 2) RelyX ARC; 3) RelyX U100; or 4) Panavia F 2.0. The silanes used were RelyX Ceramic Primer (RelyX Luting 2, RelyX ARC and RelyX U100) and Clearfil SE Bond Primer/Clearfil Porcelain Bond Activator (Panavia F 2.0). The bonded specimens were stored for 6 days in dry conditions at 37ºC before thermal cycling (10,000 cycles, 5 to 55ºC) and then tested for SBS in a mechanical testing machine (EMIC DL2000). Data were analyzed by two-way ANOVA and Tukey HSD post hoc test ( =.05). Failure mode was determined with a stereomicroscope (×20). The... (Complete abstract click electronic access below) / Mestre
42

Efeito do avanço da frente de umidade na redução da sucção e da resistência ao cisalhamento de um perfil de solo coluvionar em Medellín-Colômbia

Lôbo, Bruno Rogério da Hora 09 November 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2012. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-03-05T11:58:48Z No. of bitstreams: 1 2012_BrunoRogeriodaHoraLobo.pdf: 4087635 bytes, checksum: 1b41a46199858e44eff9745f5cb27247 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-03-27T11:11:09Z (GMT) No. of bitstreams: 1 2012_BrunoRogeriodaHoraLobo.pdf: 4087635 bytes, checksum: 1b41a46199858e44eff9745f5cb27247 (MD5) / Made available in DSpace on 2013-03-27T11:11:09Z (GMT). No. of bitstreams: 1 2012_BrunoRogeriodaHoraLobo.pdf: 4087635 bytes, checksum: 1b41a46199858e44eff9745f5cb27247 (MD5) / Os movimentos de massa causados pelas chuvas, geralmente denominados deslizamentos superficiais complexos, caracterizam-se por apresentar pequenos perfis com espessuras que variam entre 0,3 e 2,0 m. Para entender esses movimentos de terra provocados por chuvas em regiões montanhosas sob condições de clima tropical, este estudo buscou elucidar a questão da redução da sucção e a consequente perda de resistência em um perfil de solo coluvionar devido ao avanço da frente de umidade em um talude natural localizado na cidade de Medellin - Colômbia. Neste talude, o objetivo foi verificar a aplicabilidade da equação de Lumb (1975) para determinar o avanço da frente de umidade em perfis de solo não saturados, desencadeado pela infiltração da chuva. Esta equação é utilizada para calcular a profundidade crítica (profundidade onde a perda máxima de sucção ocorre). A profundidade crítica obtida pela equação de Lumb foi comparada com a obtida pelos perfis de sucção, antes e depois das chuvas. Os perfis de sucção foram obtidos a partir de simulações numéricas, utilizando um método de infiltração que inclui uma relação de sucção-saturação (van Genuchten, 1980). Com as propriedades do solo, os parâmetros de infiltração e da geometria do talude, foi possível obter os fatores de segurança para o talude estudado. Os resultados deste trabalho são a determinação de uma metodologia consistente para a determinação da profundidade crítica da frente de umidade gerado pela infiltração de chuva. _______________________________________________________________________________________ ABSTRACT / Slope failures caused by rainfall are characterized by shallow depths with thicknesses ranging between 0.3 and 2.0 m. In order to understand these landslides triggered by rainfalls in mountainous regions under tropical climate, this study tried to elucidate the issue of reduction of suction and the consequent loss of strength in a colluvial soil profile due to the advance of the wetting front in natural slopes located in the city of Medellin – Colombia. In these slopes, the purpose was to verify the applicability of the Lumb’s equation (1975) in determining the advance of the water front on unsaturated soil profiles triggered by the rainfall infiltration. This equation is used to estimate the critical depth (depth where the maximum loss of suction occurs). The critical depth obtained by Lumb’s equation was compared with that obtained by the suction profiles, before and after the rainfalls. The suction profiles were obtained from numerical simulations using a seepage method which includes a suction-saturation relationship (van Genuchten, 1980). With the soil properties, the infiltration parameters, and geometry of the slopes, it was possible to obtain the safety factors for the studied slopes. The results of this work are the determination of a consistent methodology for determining the critical depth of the water front generated by the rainfall infiltration.
43

Influência da desproteinização dentinária radicular na cimentação de pinos estéticos

Guimarães, Renata Pedrosa 17 December 2012 (has links)
Submitted by Leonardo Freitas (leonardo.hfreitas@ufpe.br) on 2015-04-14T13:58:42Z No. of bitstreams: 2 TESE Renata GUIMARÃES.pdf: 2863665 bytes, checksum: 158d65a6ff45fcb1c843a03fbded403d (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-14T13:58:42Z (GMT). No. of bitstreams: 2 TESE Renata GUIMARÃES.pdf: 2863665 bytes, checksum: 158d65a6ff45fcb1c843a03fbded403d (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-12-17 / CAPES / Objetivo: Avaliar o desempenho de cimentos resinosos frente à desproteinização dentinária através de ensaio de cisalhamento por extrusão de pinos de fibra de vidro. Método: Raízes de 83 pré-molares inferiores humanos foram divididas em 2 grupos conforme o tratamento da dentina (Convencional – recomendações do fabricante e Desproteinização – NaOCl 5,0%/1min). Cada grupo foi dividido em 4 subgrupos segundo o cimento utilizado na cimentação dos pinos de fibra de vidro (Relyx ARC/3M-ESPE; SET/SDI; RelyxU100/3M-ESPE; Cement Post/Angelus). Após 1 semana foi realizado o ensaio push-out. O padrão de falha pós-ensaio foi obtido, de cada corpo de prova, por microscopia óptica. Os dados foram analisados pelo teste F (ANOVA) com comparações de Tukey ou de Tamhane e t-Student (α=5%). Para 3 espécimes foi realizada análise em MEV quanto à morfologia da dentina segundo o tipo de condicionamento. Resultados: A desproteinização influenciou positivamente o desempenho do Cement Post (Terço médio) e Relyx U100 (Terço apical), negativamente para o RelyxARC (Terços cervical e apical) e indiferentemente para o SET. O RelyX U100 e ARC apresentaram os maiores valores de adesão comparados ao SET e Cement Post. O terço cervical apresentou os melhores resultados, com exceção do RelyX U100, no qual o terço apical foi superior. Falhas adesivas foram mais prevalentes no terço cervical (> 50%) e as mistas nos terços médio e apical (>50%). Conclusões: 1. A desproteinização influenciou positivamente a adesão quando empregados o Cement Post (terço médio) e RelyX U100 (terço apical); 2. O Relyx U100 e Relyx ARC obtiveram os melhores resultados
44

Verificação ao cisalhamento em lajes nervuradas

FONTES, Luiz José Gonçalves 23 February 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-14T19:49:36Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luiz José Gonçalves Fontes.pdf: 2051860 bytes, checksum: 44156147dd32512a7f10a1590206c9e2 (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-08-16T19:51:23Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luiz José Gonçalves Fontes.pdf: 2051860 bytes, checksum: 44156147dd32512a7f10a1590206c9e2 (MD5) / Made available in DSpace on 2018-08-16T19:51:23Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Luiz José Gonçalves Fontes.pdf: 2051860 bytes, checksum: 44156147dd32512a7f10a1590206c9e2 (MD5) Previous issue date: 2017-02-23 / O uso de lajes nervuradas tem sido uma prática constante nas obras de construção civil. Esse tipo de laje, constituída de nervuras (em uma ou mais direções) ligadas entre si por uma mesa, proporciona uma economia maior de concreto em relação a uma laje maciça, uma vez que é eliminado o concreto que fica, normalmente, na região tracionada entre as nervuras. Um dos inconvenientes desse tipo de laje, devido ao formato das nervuras (geralmente com seções trapezoidais para facilitar a desforma) e a presença das armaduras de flexão, é a montagem dos estribos, quando há necessidade de armadura para combater o cisalhamento, principalmente no Brasil, onde não são comercialmente fabricadas armaduras padronizadas que se adequem ao formato das nervuras. Sendo assim, a dispensa da armadura de cisalhamento, quando possível, deve ser adotada de forma a melhorar o processo de montagem do sistema. No presente trabalho são apresentadas as prescrições da normas Canadense, Americana e Brasileira, que usam parâmetros distintos para as verificações do cisalhamento em nervuras e elementos de seções em formato trapezoidais, e apresentados resultados de ensaios descritos na literatura de nervuras contínuas de concreto armado, com e sem armadura de cisalhamento. Em seguida esses resultados são comparados com os calculados segundo as normas citadas e apresentadas conclusões e recomendações para verificação, detalhamento e dispensa de armadura de cisalhamento em nervuras sendo sugerido a adoção de um coeficiente de minoração para a equação da Norma Brasileira que limita a resistência máxima ao cortante para dispensa de armadura de cisalhamento nesses elementos. / The use of joist slabs has been a constant practice in civil construction. This type of slab consists of ribs connected to each other by a table, provides a greater saving of concrete in relation to a solid slab, since the concrete that is usually in the region is eliminated Between the ribs. One of the drawbacks of this type of slab, due to the shape of the ribs (generally tapered webs to facilitate the withdrawal of forms) and the presence of flexural reinforcement, is the placement of the stirrups when there is a need for reinforcement to resist shearing, mainly in Brazil, where they are not commercially manufactured standardized stell that conforms to the shape of the ribs. Thus, the dispensing of the shear reinforcement, when possible, must be adopted in order to improve the system assembly process. The present work presents the prescriptions of the canadian, cmerican and brazilian standards, which use different parameters for shear checks on ribs and trapezoidal shape elements, and present results of tests already performed on continuous ribs of reinforced concrete, with and without shear reinforcement. Then, these results are compared with those calculated according to the norms cited and presented conclusions and recommendations for verification, detailing and dispensing of shear reinforcement in ribs and suggested to adopt a reduction coefficient for the Brazilian Standard equation that limits the maximum strength to shear for dispensing shear reinforcement in these elements.
45

Influência do sistema adesivo e do envelhecimento na resistência ao cisalhamento da interface dentina humana-resina composta / Influence of adhesive system and aging on the shear strength of human dentin-composite resin interface

Ana Carolina Maito Villela Rosa 14 September 2012 (has links)
O propósito deste estudo foi o de avaliar a influência do sistema adesivo e do envelhecimento na resistência adesiva da interface dentina humana-resina composta. Cento e sessenta terceiros molares extraídos tiveram suas raízes removidas e as coroas seccionadas no sentido mésio-distal. As faces vestibulares foram incluídas em anel de PVC/resina acrílica e divididas em quatro grupos correspondentes aos quatro sistemas adesivos testados: um sistema adesivo de condicionamento total, como controle, Adper Single Bond 2 (ASB 2) (3M ESPE); um sistema adesivo autocondicionante de passo único, Adper Easy One (AEO) (3M ESPE); e dois sistemas adesivos autocondicionantes de dois passos, P90 System Adhesive (P90SA) (3M ESPE), e Clearfill SE Bond (CSEB) (Kuraray). Cada grupo foi dividido em quatro subgrupos correspondentes aos quatro tipos de envelhecimentos artificiais utilizados: termociclagem com 500, 10.000 e 30.000 ciclos e estocagem em água destilada a 37ºC por um ano e, após este período, termociclagem com 500 ciclos. Desta maneira, formou-se 16 subgrupos: ASB2.1, ASB2.2, ASB2.3, ASB2.4; AEO.1, AEO.2, AEO.3, AEO.4; P90SA.1, P90SA.2, P90SA.3, P90SA.4; CSEB.1, CSEB.2, CSEB.3, CSEB.4. Após o envelhecimento artificial padronizado foi realizado o teste de resistência ao cisalhamento ISO TR 11405, usando uma máquina universal de testes EMIC-2000, regulada a 0,5mm/minuto e célula de carga de 200 Kgf. Os resultados foram submetidos à análise estatística de variância (Testes ANOVA, Tukey e Scheffé). Houve diferença estatística significante (p<0,01) para dois fatores de variação (adesivo e envelhecimento) e a interação adesivo x envelhecimento (p<0,01) não apresentou diferença estatística significante. O adesivo Adper Single Bond 2, apresentou maiores valores, enquanto que, o P90 System Adhesive, os menores valores de resistência adesiva ao cisalhamento em relação aos demais sistemas adesivos. A termociclagem de 500 ciclos e a estocagem em água a 37ºC por um ano, seguida de 500 ciclos térmicos apresentaram os mais elevados valores de resistência adesiva, sem diferenças estatísticas significantes, assim com a termociclagem de 10.000 e 30.000 ciclos apresentaram os valores mais baixos. Baseado nestes achados pode-se concluir o sistema adesivo e o envelhecimento influenciaram a resistência ao cisalhamento da interface dentina humanaresina composta. / The purpose of this study was to evaluate the influence of the adhesive system and aging on the bond strength of human dentin-composite resin interface. One hundred and sixty extracted third molars had their crowns removed and the roots sectioned mesiodistally. The buccal faces were included ring PVC/acrylic resin and they were divided into four groups corresponding to the four tested adhesive systems tested. A total etch adhesive system, as controls, Adper Single Bond 2 (ASB 2) (3M ESPE), an all-in-one self-etching adhesive system, Adper Easy One (AEO) (3M ESPE) and two two steps self-etching adhesive systems, P90 System Adhesive (P90SA) (3M ESPE), and Clearfill SE Bond (CSEB) (Kuraray). Each group was divided into four subgroups corresponding to four types of used artificial aging: thermocycling with 500, 10,000 and 30,000 cycles and storage in distilled water at 37°C for one year and after this period, thermocycling with 500 cycles. Thus was formed 16 subgroups: ASB2.1, ASB2.2, ASB2.3, ASB2.4; AEO.1, AEO.2, AEO.3, AEO.4; P90SA.1, P90SA.2, P90SA.3, P90SA.4; CSEB.1, CSEB.2, CSEB.3, CSEB.4. After accelerated aging test was standardized shear bond strength ISO TR 11405, using a universal testing machine (EMIC-2000) set at 0.5 mm/minute and a load cell of 200 kgf. The results were subjected to statistical analysis of variance (ANOVA, Tukey and Scheffe). There was a statistically significant difference (p<0.01) for two factors of variation (adhesive and aging) and not for the interaction adhesive x aging (p<0.01). The adhesive Adper Single Bond 2 showed higher values of shear bond strength, whereas the P90 System Adhesive showed the lowest values of shear bond strength compared to other adhesive systems. The thermocycling regimen of 500 cycles and storage in water at 37°C for one year, followed by 500 thermal cycles showed the highest bond strength values, no statistically significant differences, as well as thermocycling of 10,000 and 30,000 cycles showed the lowest values. Based on these findings it can be concluded the adhesive system and aging affected the shear bond strength of human dentin-composite resin interface.
46

Análise de resistência ao cisalhamento em peças de seções circulares vazadas utilizando a teoria do campo de compressão modificada.

Queiroz Junior, Francinaldo de Oliveira 29 August 2014 (has links)
Submitted by Israel Vieira Neto (israel.vieiraneto@ufpe.br) on 2015-03-05T17:09:49Z No. of bitstreams: 2 DISSERTAÇÃO Francinaldo Junior.pdf: 3351371 bytes, checksum: d51e55bbc480ac940c502e8b1eace90f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T17:09:49Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Francinaldo Junior.pdf: 3351371 bytes, checksum: d51e55bbc480ac940c502e8b1eace90f (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014-08-29 / Peças de concreto armado com seções transversais circulares vazadas são usadas com muita frequência na engenharia. Em Recife, particularmente, o número de edificações com mais de 30 pavimentos tem apresentado crescimento notável; Muitas dessas edificações são projetadas sobre fundações de estacas circulares vazadas. Os elementos estruturais dessas edificações devem transmitir, de forma segura, momentos, carregamentos axiais e esforços cortantes para as suas fundações. Desta forma, com o aumento da altura das edificações, ocorre também o aumento dos esforços cisalhantes que são transmitidos para suas fundações. Por outro lado, estes elementos vazados são mais críticos em relação ao cisalhamento devido ao seu núcleo vazio. As normas e diretrizes para avaliação da resistência ao cisalhamento de peças com tais seções transversais são praticamente não existentes, e a maioria dos requisitos das normas existentes, dentre elas a NBR 6118, foram baseados em modelos de cisalhamento para seções retangulares. Este estudo buscou avaliar, de forma comparativa, a resistência ao cisalhamento de peças com seções transversais circulares vazadas, obtidas de ensaios experimentais encontrados na literatura, com valores calculados utilizando a Teoria do Campo de Compressão Modificada através da norma canadense (CSA A23.3-04). Ao final, foi proposto, baseado nas normas existentes e nos dados experimentais, parâmetros para avaliação da altura útil, d, e largura efetiva, bw, a serem sugeridos para a NBR 6118, de forma a possibilitar o calculo das forças cortantes resistentes em peças com seções circulares vazadas, e ao mesmo tempo garantir que cada resistência calculada seja menor que a obtida experimentalmente.
47

Efeito da inclusão de tiras poliméricas de polietileno tereftalato e da adição de cimento na resistência mecânica de solo arenoso laterítico /

Silveira, Maitê Rocha January 2019 (has links)
Orientador: Paulo César Lodi / Resumo: A proposição de uso de materiais alternativos na construção civil que busquem reduzir a produção de resíduos ou utilizar resíduos anteriormente gerados mostra-se cada vez mais necessária, uma vez que a indústria da construção civil situa-se hoje como uma das maiores consumidoras de matérias-primas naturais. Dessa forma, este trabalho avaliou os efeitos que a inclusão de tiras poliméricas de polietileno tereftalato (PET) cortadas a partir de garrafas plásticas descartadas, e de cimento geram na resistência mecânica de um solo arenoso retirado da região de Bauru (SP). Foram realizados ensaios de resistência uniaxial em solo puro e com a inclusão aleatória de tiras de PET em diferentes comprimentos e porcentagens. Além dos ensaios de resistência não confinada, foram realizados também ensaios de compactação com adições de cimento e com adições de tiras de PET, a fim de se analisar os efeitos destas inclusões aos parâmetros compactação da matriz arenosa. Por fim, foram realizados também ensaios de cisalhamento direto em compósitos de solo-tira, solo-cimento e em compósitos de solo-cimento-tira, tornando possível a avaliação dos efeitos individuais de cada tipo inclusão na resistência ao cisalhamento da matriz. Em relação à resistência uniaxial notou-se o aumento da resistência da matriz arenosa devido à inclusão de tiras, independente do tamanho e percentagens analisadas. Quanto aos ensaios de cisalhamento direto, a adição de cimento foi efetiva aumentando tanto a coesão, quanto o... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The proposition of using alternative materials in construction that seek to reduce waste production or use previously generated waste is becoming increasingly necessary, as the construction industry is today one of the largest consumers of natural resources. Thus, this work evaluated the effects that the inclusion of polyethylene terephthalate (PET) strips cut from waste plastic bottles, and cement generate on the mechanical strength of a sandy soil from Bauru (SP). Unconfined strength tests were performed in pure soil and with the random inclusion of PET strips in different lengths and percentages. In addition to the unconfined strength tests, were also performed compaction tests with cement additions and with addition of PET strips, in order to analyze the effects of these inclusions on the sandy soil. Finally, direct shear tests were also performed on soil-strip, soil-cement and soil-cement-strip composites, making it possible to evaluate the individual effects of each inclusion on the shear strength of the analyzed soil. Regarding the uniaxial resistance, the soil resistance increased due to the inclusion of strips, regardless of the size and percentages analyzed. As for the direct shear tests, the cement addition was effective increasing both the cohesion and the soil friction angle in large proportions. The addition of strips to the soil-cement composite had its most pronounced effect on increasing soil cohesion, often reducing the friction angle. In general, the additi... (Complete abstract click electronic access below) / Mestre
48

Resistência ao cisalhamento de bráquetes ortodônticos cerâmicos colados com diferentes compósitos e irradiados com laser de CO2 / Shear strength of ceramic orthodontic brackets bonded with different composites and irradiated with CO2 laser

Matos, Denise de Souza 25 April 2013 (has links)
O objetivo do trabalho foi avaliar a resistência ao cisalhamento de bráquetes ortodônticos cerâmicos com base de retenção química e mecânica, colados com diferentes compósitos e irradiados com laser de CO2. Foram utilizados 120 pré-molares humanos hígidos, suas coroas foram incluídas em resina acrílica e as faces vestibulares planificadas e polidas com lixas d\'água até exposição de 5mm esmalte. Posteriormente, as raízes dos dentes foram incluídas em tubos de PVC também com resina acrílica de forma que a face vestibular ficasse perpendicular à base do tubo. Os 120 corpos de prova foram divididos em 8 grupos (n=15), sendo 2 controles e 6 experimentais. Nos grupos 1 e 2 (controles) o compósito utilizado para colagem foi o Transbond XT, sendo que no grupo 1 foi colado o bráquete cerâmico Mystique (retenção mecânica) e no grupo 2 o bráquete cerâmico Fascination (retenção química). Nos grupos experimentais 3, 4 e 5 foi colado o bráquete Mystique com os compósitos Transbond XT, Concise e Z250, respectivamente. Nos grupos 6, 7 e 8 foi colado o bráquete Fascination com os mesmos compósitos dos grupos 3, 4 e 5, na mesma sequência. Nos grupos experimentais, após a colagem, os bráquetes foram irradiados com laser de CO2 com 10W de potência por 3 segundos e pulso de 0,01 segundo. Imediatamente após a irradiação foi realizado o teste de resistência ao cisalhamento da colagem em máquina universal de ensaios mecânicos (Emic DL 500) à velocidade de 0,5 mm/minuto. Após o teste, as superfícies avaliadas por meio do Índice de Remanescente Adesivo (IRA) e submetidas à Microscopia Eletrônica de Varredura (MEV) para investigação de eventuais fraturas. Os dados de resistência ao cisalhamento foram submetidos à Análise de Variância ANOVA e posteriormente teste de Tukey. O teste de Mann-Whitney foi utilizado para a avaliação do IRA. Os resultados mostraram que os grupos experimentais apresentaram valores de resistência ao cisalhamento menores quando comparados aos controle (p 0,05). O bráquete Mystique (retenção mecânica) apresentou valores maiores de resistência ao cisalhamento e o compósito Z 250 foi o que apresentou menor força de adesão após irradiação com laser de CO2. Os grupos 5 e 8 foram os que apresentaram maior média do IRA e para todas as superfícies avaliadas o modo de fratura mais prevalente foi a fratura adesiva . Concluiu-se que o laser de CO2 foi eficaz como auxiliar na descolagem de bráquetes cerâmicos de retenção química e mecânica. / The objective of this study was to evaluate the shear strength of the ceramic orthodontic brackets based in chemical and mechanical restraint, bonded with different composites and irradiated with CO2 laser was evaluated. Healthy human premolars (120) were used and their crowns were embedded in acrylic resin and the buccal surfaces flattened and polished with sandpaper until exposure of 5 mm of enamel. Subsequently, the roots of the teeth were included in PVC pipes also with acrylic resin so that the labial surface was perpendicular to the base of the pipe. The 120 samples were divided into 8 groups (n = 15), 2 being the control groups and 6, the experimental groups. In groups 1 and 2 (controls) the composite used for bonding was Transbond XT. Group 1 was glued to the ceramic bracket Mystique (by mechanical retention) and the group 2, with ceramic bracket Fascination (by chemical restraint). In the experimental groups 3, 4 and 5 Mystique brackets were glued with Transbond XT, Concise and Z250, respectively. In groups 6, 7 and 8 the Fascination bracket were glued with the same composites of groups 3, 4 and 5 and in the same sequence. In the experimental groups, after bonding, the brackets were irradiated with CO2 laser with 10W of power for 3 seconds and per pulse 0.01 seconds. Immediately after irradiation shear strength tests were performed on shear bonding with mechanical universal testing machines (Emic DL 500) at a speed of 0.5 mm/minute. After testing, the surfaces were evaluated using the Adhesive Remnant Index (ARI) and submitted to scanning electron microscopy (SEM) to investigate possible fractures. The shear strength data were subjected to analysis of variance with ANOVA and Tukey test later. The Mann-Whitney test was used to evaluate the ARI. The results showed that experimental groups showed lower shear strength values, comparing to the control groups (p 0.05). The bracket Mystique (mechanical retention) showed higher shear strength values and the Z 250 composite showed the lowest adhesion strength after irradiation with CO2 laser. Groups 5 and 8 presented the highest average of IRA and for all the surfaces that were evaluated the most prevalent fracture mode was the adhesive one. It was concluded that the CO2 laser was effective as an aid in bracket debonding of ceramic with chemical and mechanical retention.
49

Resistência de união entre cimentos resinosos e zircônia / Bond strenght between resin cements and zirconia

Valdivia, Juan Rommel Medina 18 August 2011 (has links)
Este estudo avaliou a resistência de união de cimentos resinosos à zircônia tetragonal parcialmente estabilizada com ítrio (NobelProceraTM Zircônia) submetida a tratamentos superficiais mecânicos e químicos. Os cimentos utilizados foram o cimento resinoso auto-condicionante de polimerização química Multilink (Ivoclar Vivadent) associado ao Metal/Zirconia Primer (Ivoclar Vivadent) e o cimento resinoso auto-adesivo de polimerização química e dual RelyX U100 (3M-ESPE) associado ao adesivo Adper Single Bond Plus 2 (3M-ESPE). Utilizando 40 cilindros de zircônia (diâmetro de 3,5 mm) foram realizados 120 ensaios (n=40 para cada cimento). Para cada cimento os cilindros foram divididos em 4 grupos (n=10) em função do tratamento superficial avaliado: 1- sem tratamento; 2- agente de união (primer ou adesivo); 3- jateamento com oxido de alumínio 50µm; 4- associação do jateamento e o agente de união. A aplicação do cimento resinoso foi realizada utilizando uma matriz de teflon com orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Após a aplicação de cada cimento nas 4 condições de superficie, os espécimes foram armazenados em água deionizada a 37ºC durante 24h e submetidos ao teste de resistência ao cisalhamento. Os resultados foram analisados com ANOVA a dois critérios e teste de Tukey (p<0,05). Sem tratamento superficial o RelyX U100 químico (5,52 Mpa) e dual (6,53 Mpa) tiveram melhor comportamento que o cimento Multilink (0,76). A associação do jateamento e o agente de união melhorou os valores de resistência de união para o cimento Multilink (7,68 Mpa) e para o cimento RelyX U100 dual (10,26 Mpa), sendo este último superior a todos os outros grupos. A associação do Adper Single Bond Plus 2 e o RelyX U100 sem jateamento, deve ser evitado. / The aim of this study was to evaluate the shear bond strength of resin cements to the yttria stabilized tetragonal zirconia (NobelProceraTM Zirconia) subjected to mechanical and chemical surface treatments. The cements used were: a self-etching resin cement with chemical polymerization Multilink (Ivoclar - Vivadent) associated to the Metal / Zirconia Primer (Ivoclar - Vivadent) and self-adhesive resin cement with chemical and dual polymerization RelyX U100 (3M-ESPE) associated to the adhesive Single Bond Plus Adper 2 (3M-ESPE). Using 40 cylinders of zirconia (3.5 mm diameter) were performed 120 trials (n = 40 for each cement). For each cement, cylinders were divided into four groups (n = 10) based on the surface treatment rated: 1 - untreated, 2 - bonding agent (primer or adhesive) 3 air abrasion with 50µm aluminum oxide, 4 - combination of air abrasion and bonding agent. The application of resin cement was performed using a teflon matrix with a central hole 3.5 mm in diameter and 3.0 mm deep. After application of each cement in the four surface conditions, the specimens were stored in deionized water at 37 ° C for 24 hours and tested for shear bond strength. Results were analyzed with an ANOVA Two Criteria and Tukey\'s test (p <0.05). Without surface treatment, chemical RelyX U100 (5.52 MPa) and dual (6.53 MPa) had better behavior than Multilink Cement (0.76). The combination of air abrasion and bonding agent improved the bond strength values for Multilink (7.68 MPa) and for RelyX U100 dual (10.26 MPa), this one superior to all other groups. The association of Adper Single Bond 2 and RelyX U100 Plus without air abrasion, should be contraindicated.
50

Resistência de Interface entre geomembranas e solos através do ensaio de Ring Shear / Interface strength between geomembranes and soils by ring shear test

Rebelo, Karla Maria Wingler 12 December 2003 (has links)
Investiga-se neste trabalho a resistência ao cisalhamento em interfaces geomembrana-solo, utilizadas nos sistemas de impermeabilização de aterros e lagoas de efluentes. Foram realizados ensaios de ring shear envolvendo solos arenosos e argilosos, em condição seca e inundada. Os ensaios foram realizados utilizando uma areia de granulometria grossa a média e um solo argiloso proveniente do aterro sanitário de Piracicaba- SP. Neste trabalho foram utilizadas geomembranas de polivinil clorado, polietileno linear de média densidade e polietileno de alta densidade, com diferentes níveis de rugosidade. Os resultados mostraram que a resistência ao cisalhamento depende das características das geomembranas utilizadas, como flexibilidade e rigidez, além de outras. Conforme esperado, observou-se que as geomembranas texturizadas apresentaram maiores valores de ângulo de atrito do que as geomembranas lisas; enquanto as geomembranas flexíveis mostraram maiores valores de ângulo de atrito que as rígidas. Este comportamento foi verificado em ambos os tipos de interface. Verificou-se também que o efeito da compacidade dos materiais granulares e da saturação dos materiais mostrou-se pouco acentuado na resistência de interface areia/geomembrana. Nos ensaios de interface com solo argiloso foi verificado que a inundação influencia na resistência de interface, fornecendo menores valores de ângulos de atrito do que nos ensaios não inundados. Além deste aspecto, verificou-se que a resistência de interface em ensaios não inundados depende da umidade de compactação do solo argiloso. Este fato não foi verificado nos ensaios inundados. / This paper deals with the shear strength in the geomembrane-soil interfaces used in landfill and waste pond liners. Modified ring shear tests were carried out using sandy and clayey soils, in dry and saturated conditions. The tests were performed using a coarse to medium graded sand and a clayey soil from a sanitary landfill in Piracicaba - SP. In this work, polyvinyl chloride geomembranes, medium density linear polyethylene and high-density polyethylene, with different roughness levels, were used. The test results showed that the shear strength depends on several geomembrane characteristics, such as roughness and stiffness. As it was expected, texturized geomembranes showed higher friction angle values than smooth geomembranes; flexible geomembranes showed higher friction angle values than the stiff ones. Such behavior was verified in both interface types. Also, it was verified that the sand compaction and the material saturation have little influence on the sand-geomembrane interface shear strength. The interface shear strength tests, performed with a clayey soil, showed that the wetting condition affects the interface shear strength. Friction angle for wetted samples were smaller than those for non-wetted samples. In addition, it has been verified that the interface shear strength in non-wetted tests depends on the moisture content of the clayey soil. This fact has not been verified in the wetted tests.

Page generated in 0.5057 seconds