• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 161
  • Tagged with
  • 161
  • 161
  • 141
  • 136
  • 68
  • 58
  • 58
  • 55
  • 51
  • 49
  • 42
  • 40
  • 33
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Estudo da distribuição de tensões e da resistência à tração de interfaces adesivas dentina-resina de duas formas de espécimes submetidos a diferentes protocolos de envelhecimento acelerado / Study of stress distribution and tensile bond strength of dentin-resin adhesive interfaces of two types of specimens submitted to different protocols of accelerated aging

Sanches, Luciana Katty Figueiredo 08 July 2011 (has links)
O acelerado e freqüente desenvolvimento de novos materiais e técnicas restauradoras tornam necessárias avaliações rápidas que estimem seus desempenhos clínicos. Este estudo avaliou protocolos de envelhecimento acelerado, in vitro, capazes de simular o desempenho de restaurações adesivas frente aos desafios inerentes ao ambiente oral. Foram utilizados 36 molares hígidos, cortados ao meio e divididos aleatoriamente em 12 grupos. Em todos os grupos foi realizada a exposição da superfície dentinária, delimitação da área de adesão e condicionamento ácido da superfície, seguida a aplicação do Sistema Adesivo Scotchbond Multiuso, e colocação da resina composta Z100, em incrementos. Foram confeccionados 6 grupos em formato de palito e 6 grupos em formato de haltere: dois grupos não foram submetidos à ciclagem térmica e mecânica (STSM-P e STSM-H); outros dois foram submetidos à ciclagem térmica (1.000 ciclos; 5-55ºC; 1min em cada banho) e não a mecânica (CTSM-P e CTSM-H); dois ainda foram submetidos à ciclagem mecânica com dispositivo Nova Ética e não a térmica (STNE-P e STNE-H); dois foram submetido à ciclagem mecânica com dispositivo Nova Ética (500.000 ciclos), acrescido de ciclagem térmica (CTNE-P e CTNE-H); outros dois por fim, foram submetidos à ciclagem mecânica por Microrotação (105 ciclos, aproximadamente por 7 horas), e não a térmica (STMR-P e STMR-H); por fim os dois últimos grupos foram submetido à ciclagem mecânica por Microrotação acrescido de ciclagem térmica (CTMR-P e CTMR-H). Todos os grupos foram preparados para teste de microtração. Com as medidas de resistência de união dos palitos e halteres de cada dente foi realizada análise de variância e teste de Tukey. A interação tripla Formato -FORM- (Palito ou haltere) X Ciclagem Térmica- T- (Com e Sem) X Ciclagem Mecânica-M- (Nova Ética e Microrotação) não foi significante (p=0,698), bem como a interação 2 a 2 dos mesmos fatores: FORMxT (p=0,391); TxM (p=0,477); FORM x M (p=0,746). O fator Formato do espécime (Palito ou Haltere) teve diferença extremamente significante (p=0,000), sendo que os valores dos halteres foram maiores que os dos palitos. O fator Ciclagem Térmica (Com e Sem) não foi estatisticamente significante (p=0,2), bem como o fator Ciclagem Mecânica (Nova Ética e Microrotação) (p=0,587). Pode-se concluir que: a ciclagem térmica, bem como as ciclagens mecânicas sistema Nova Ética e Microrotação não foram capazes de reduzir significativamente os valores de resistência de união das interfaces adesivas, nem quando aplicadas isoladamente, nem quando associadas; os espécimes com formato de palito apresentaram valores de resistência de união menores do que os em formato de haltere; não foi possível estabelecer nenhum padrão de degradação entre os grupos através da microscopia eletrônica de varredura; os elementos finitos identificaram uma distribuição mais homogênea das tensões geradas na interface dos espécimes em formato de haltere. / The rapid and frequent development of new materials and restorative techniques necessitate rapid assessments to estimate their clinical outcomes. This study sought to evaluate protocols for accelerated aging, in vitro, capable of simulating the performance of adhesive restorations with challenges inherent to the oral environment. The study included 36 molars that were randomly divided into 12 groups. In all groups were exposed dentin surface, defining the area of adhesion and etching the surface, then the application of Scotchbond Multipurpose Adhesive System, and placement of composite resin Z100, in increments. Six groups were fabricated in the shape of sticks and six other groups in dumbbell shape: the first was not subjected to thermal cycling and mechanical (STSM-P and STSM-H), the second was subjected to thermal cycling (10,000 cycles, 5-55 ° C) and not the mechanics (CTSM-P and CTSM-H); the third was subjected to mechanical cycling device with new Ethics (500,000 cycles) and not thermal (STNE-P and STNE-H); the fourth was subjected to mechanical cycling device with new Ethics, plus thermal cycling (CTNE-P and CTNE-H); the fifth was submitted the mechanical cycling device for Microrotation (105 cycles), but not thermal (STMR-P and STMR-H) and finally the sixth was subjected to mechanical cycling device for Microrotation plus thermal cycling (CTMR-P and CTMR-H). All groups were prepared for microtensile bond-strength test. With the measures of bond strength of each tooth was performed statistical analysis (ANOVA and Tukey test). Random samples of specimens were evaluated by SEM. The triple interaction format (stick or dumbbell-shaped) X Thermal cycling (with and without) X Cycling Mechanics (New Ethics and Microrotation) was not significant (p = 0.698), as well as the interaction 2-2 of the same factors: FORMXT (p = 0.391); TXM (p = 0.477); FORMxM (p = 0.746). With regard to factor Format specimen is observed that the bond strength values obtained for the dumbbell-shaped are higher than those obtained for the sticks (p = 0.000). With regard to factor Thermal cycling was observed that the difference was not statistically significant (p = 0.2). As for factor Cycling Mechanics, the values of groups without cycling were very similar to those obtained in groups cycled through the system New Ethics, and the system by Microrotation, no significant difference between any of them (p = 0.587). The conclusions were that the stick-shaped specimens showed values of bond strength lower than the dumbbell-shaped; thermocycling and mechanical cycling were not able to significantly reduce the values of bond strength of adhesive interfaces, even when applied alone or when associated. It could not be establish any pattern of degradation among the groups by SEM; the finite element identified a more homogeneous distribution of stresses generated at the interface of dumbbell shaped specimens.
32

Influência da presença de um filme fino de platina na resistência de união titânio-cerâmica

Rodrigues, Flávia Pires [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T19:16:39Z : No. of bitstreams: 1 rodrigues_fp_me_guara.pdf: 4184618 bytes, checksum: edb4c6c9b5b186971c9e548252d87136 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Problemas com a resistência de união metal-cerâmica têm sido encontrados quando o titânio é utilizado em Odontologia. A proposta deste estudo foi aumentar a resistência na interface titânio-cerâmica pela aplicação de um filme fino de platina na superfície do titânio, por meio da utilização da técnica de deposição por pulverização catódica. Dez padrões (1.0 x 4.0 x 30 mm) foram obtidos por meio de cortes de placas de resina acrílica e incluídos em um revestimento à base de zircônia. As fundições de titânio para preenchimento dos moldes foram realizadas em uma máquina de fundição centrífuga. As amostras foram lixadas até as dimensões finais (0.50 x 3.0 x 30 mm) para a remoção da camada -case e jateadas com pó de alumina (grupo controle) e de dióxido de titânio (grupo experimental). Uma cerâmica de ultrabaixa temperatura de fusão foi aplicada no centro da superfície (8.0 x 1.0 x 3 mm). A resistência de união foi determinada pelo teste de flexão de três pontos em uma máquina universal de ensaios com uma velocidade de 0,5mm/min. As amostras foram analisadas por meio de microscopia óptica e microscopia eletrônica de varredura antes e após os ensaios mecânicos. Os resultados revelaram valores maiores de união entre o titânio e a cerâmica quando o filme de platina foi aplicado (25,70 l 4,54 MPa), mas não houve diferença estatística significante em relação ao grupo controle (24,32 l 3,11 MPa), o que indica que o primeiro grupo também possui uma resistência de união suficiente para uso clínico. / Problems with metal-ceramic bond strength have been encountered when titanium is used in prosthetic dentistry. The purpose of this study was increase the bond strength of titanium-ceramic interface applying a platinum film on the titanium surface using DC-sputtering deposition technique. Ten 1.0 x 4.0 x 30 mm patterns were cut from sheet of acrylic resin and invested in a zirconia-based investment material. Titanium castings were made using a centrifugal casting machine. Specimens were grinded to final dimensions (0.50 x 3.0 x 30 mm) to remove the -case layer and blasted with alumina (control group) and titanium dioxide (experimental group) powders. An ultra low-fusing dental ceramic was applied to the center of the surface (8.0 x 1.0 x 3 mm). The bond strength was determined by three-point bending test. at a universal testing machine with a loading rate of 0,5mm/min.The samples were analyzed using Optical Microscopy and Scanning Electron Microscopy before and after the mechanical testing.The results showed greater values of adherence between titanium and ceramic when the platinum film was applied (25,70 l 4,54 MPa), but there were no statistic differences to those of the controls (24,32 l 3,11 MPa) that indicates that the first one has also sufficient bond strength for clinical use.
33

Análise da influência de diferentes tratamentos superficiais de sistemas cerâmicos na resistência de união adesiva

Vasconcellos, Walison Arthuso [UNESP] 26 August 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-08-26Bitstream added on 2014-06-13T19:41:15Z : No. of bitstreams: 1 vasconcellos_wa_dr_arafo.pdf: 833997 bytes, checksum: f745b0932fdc486da093b005321524ac (MD5) / A cimentação é vital para o sucesso clínico de restaurações cerâmicas puras e é dependente de muitos fatores como a composição dos materiais cerâmicos, tratamento de superfície, e agente cimentante. O objetivo deste estudo foi investigar a influência de diferentes tratamentos superficiais (microjateamento, microjateamento + condicionamento com ácido fluorídrico e silicatização) de diferentes materiais cerâmicos (Duceram Plus - Degussa, IPS Empress 2 - Ivoclar Vivadent, In-Ceram Alumina - Vita) na resistência de união adesiva, usando o teste de microtração. Dezoito terceiros molares humanos superiores recém extraídos foram usados. Os dentes foram limpos e mantidos em solução salina com timol a 0.2% em temperatura ambiente. A superfície oclusal foi cortada perpendicular ao longo eixo do dente com disco diamantado em baixa rotação em máquina de corte. Os dentes foram aleatoriamente divididos em três grupos (n=6) da seguinte forma: Grupo I. Duceram Plus - Degussa; Grupo II. IPS Empress 2 - Ivoclar Vivadent; and Grupo III. In-Ceram Alumina - Vita. Moldagens foram feitas em todos os dentes com silicona de adição e obtidos troquéis em gesso tipo IV. Cada grupo foi dividido em três subgrupos (n=2), em função do tratamento superficial (A, B e C). Tratamento A: microjateamento com óxido de alumínio 50 mm. Tratamento B: microjateamento com óxido de alumínio 50 mm, seguido de condicionamento com ácido fluorídrico a 10%. Tratamento C: microjateamento com partículas de alumina com 100 mm (Rocatec pré), seguido por jateamento com partículas de alumina modificada por sílica (Rocatec plus)... . / The cementation is vital for the clinical success of all-ceramic restorations and is dependent of many factors as composition of the ceramic materials, surface treatment and luting agent The purpose of the current study was to investigate the influence of different surface treatment (micro etching, micro etching + etching with fluoric acid and tribochemical silica coating process) of different ceramic materials (Duceram Plus - Degussa, IPS Empress 2 - Ivoclar Vivadent, In-Ceram Alumina - Vita) on bond strength at dentin, using the micro-tensile test. Eighteen freshly extracted human maxillary molars were used. The teeth were cleaned and stored in saline solution with timol 0.2% at room temperature. The occlusal surfaces were flattened perpendicular to long axis of the teeth with slow-speed diamond saw sectioning machine. The teeth were randomly divided into three groups (n=6 each) as follows: Group I. Duceram Plus - Degussa; Group II. IPS Empress 2 - Ivoclar Vivadent; and Group III. In-Ceram Alumina - Vita. Impressions were made of all teeth preparations with vinyl polysiloxane impression material and poured in a vacuum-mixed die material. Each of the 3 groups was divided into 3 sub-groups (n=2 each), in function of surface treatment (A, B e C). Treatment A: micro etching with 50 mm alumina particles. Treatment B: micro etching with 50 mm alumina particles + etching with 10% hydrofluoric acid. Treatment C: micro etching with 100 mm alumina particles (Rocatec pre) and 100 mm alumina particles modified with silica (Rocatec plus). All specimens were rinsed under running tap water and a silane solution was applied on ceramics specimens... (Complete abstract, click electronic address below).
34

Efeito do uso de primers bioativos na interface dentina-adesivo / Effect of bioactive primers on dentin--adhesive interface

Ana Beatriz Silva Sousa 29 July 2015 (has links)
A longevidade das restaurações com compósitos está diretamente relacionada ao sucesso do tratamento estético. A vida útil das restaurações pode ser influenciada por vários fatores como o material empregado, tempo de uso clínico e a degradação da matriz dentinária por metaloproteinases da matriz (MMPs), que podem afetar a integridade da interface adesiva, fazendo com que a união dentina-­adesivo seja comprometida. Assim, buscando melhores resultados na durabilidade das restaurações adesivas, o objetivo deste estudo foi avaliar o efeito de substâncias inibidoras de MMPs (soluções de clorexidina -­ CHX a 0,2% e doxiciclina a 3%) e agente de ligação cruzada (extrato de semente de uva -­ grape seed extract - GSE a 15%) na Resistência de União (RU) de restaurações de resina composta submetidas à ciclagem mecânica. Cavidades de Classe I foram preparadas na área central da superfície exposta de 48 molares humanos hígidos, posteriormente separados em 4 grupos (n=12) de acordo com o tratamento de superfície recebido após o condicionamento de ácido: Grupo I -­ Controle (Sistema Adesivo -­ Adper Single Bond Plus -­ 3M ESPE); Grupo II -­ CHX 0,2% + Sistema Adesivo; Grupo III -­ GSE 15% + Sistema Adesivo e Grupo IV -­ Doxiciclina 3% + Sistema Adesivo. Após os procedimentos restauradores (Filtek Supreme Ultra -­ 3M ESPE), as amostras foram armazenadas em água destilada durante 24 horas a 37°C e subdividas em dois subgrupos: A -­ Controle (armazenado em saliva artificial) e B -­ Submetido à ciclagem mecânica (Coil Cycler, Proto-­tech, forca de 50 N, frequência de 1,5 Hz em 1 x 106 ciclos de aplicação). Após ciclagem mecânica, os corpos de prova foram cortados em palitos (0,8 x 0,8 mm; n = 5 por dente) e submetidos ao teste de microtração (Bisco) a velocidade de 1 mm/min. A atividade colagenolítica da MMP-­2 sob a ação dos primers bioativos foi analisada utilizando o kit EnzChek Gelatinase/Colagenase Assay (D-­12054, Molecular Probes, Eugene, OR, EUA). A atividade gelatinolítica das MMPs-­2 e -­9 após incubação com os primers bioativos foi avaliada através de zimografia convencional. Os resultados obtidos das duas análises foram apresentados na forma de porcentagem de inibição. Zimografia in situ foi realizada utilizando gelatina de fluorescência conjugada (Kit EnzChek Gelatinase/Collagenase Assay) como substrato de MMPs e avaliada com aumento de 40x através de microscopia de fluorescência. Posteriormente, os fótons fluorescentes foram analisados em software (ImageJ). Obtidos os resultados, os dados foram submetidos à análise estatística (2way ANOVA, Tukey, p>0,05) e demonstraram que os primers bioativos não exerceram influência significante sobre a RU dentina-­adesivo, independente da ação da ciclagem mecânica. A atividade colagenolítica, segundo zimografia convencional, demonstrou que os primers bioativos foram capazes de inibir as MMPs, sendo a CHX menos eficiente. Na análise de zimografia in situ, os primers bioativos diminuíram a atividade das MMPs localizadas na interface adesiva, com aumento da atividade gelatinolítica do grupo Controle sendo maior quando submetidos à ciclagem mecânica, efeito não encontrados no grupos tratados com primers bioativos. Concluiu-­se que, apesar de não apresentarem efeitos sobre a RU da interface adesiva, os primers bioativos apresentam ação sobre a degradação da camada híbrida. / The durability of composite resin restorations is one of the main points related to the success in aesthetic treatments. The longevity of adhesive restorations can be affected by various factors such as the materials, the clinical time of use and the dentin matrix degradation mediated by matrix metalloproteinases (MMPs). MMPs can affect the adhesive interface, compromising the bonding between dentin and adhesive. Thus, searching for better results on longevity of adhesive restorations, the aim of this study was to evaluate the effect of MMPs inhibitors (chlorhexidine -­ CHX 0.2% and doxycycline 3% ) and crosslinking agent (grape seed extract -­ GSE 15%) on resin composite bond strength (BS) of restorations submitted to load cycling. Class I cavities were performed in the central area of the exposed surface of 48 sound human molars. Then, it was divided into 4 groups (n=12) according to the surface treatment received after the acid etching: Group I -­ Control (Adhesive System -­ Adper Single Bond Plus -­ 3M ESPE); Group II -­ CHX 0.2% + Adhesive System; Group III -­ Doxycycline 3% + Adhesive System e Group IV -­ GSE 15% + Adhesive System. After restorative procedures (Filtek Supreme Ultra -­ 3M ESPE), the samples were stored in distilled water for 24 hours at 37°C and then subdivided into two subgroups (n=6): A -­ Control (stored in artificial saliva) and B -­ Submitted to load cycling (Coil Cycler, Proto-­tech, 50 N, 1.5 Hz, 1 x 106 cycles). After load cycling, the specimens were cut into sticks (0.8 x 0.8 mm; n = 5 per teeth) and submitted to the microtensile test (Bisco) at 1 mm/min. The collagenolytic activity of MMP-­2 under action of bioactive primers was analyzed using EnzChek Gelatinase/Colagenase Assay Kit (D-­12054, Molecular Probes, Eugene, OR, EUA). The gelatinolytic activity of MMPs-­2 and -­9 after incubation with the bioactive primers was evaluated by gelatin zymography. The results of these two analyzes were presented by percentage of inhibition. In situ zymography was performed using fluorescence conjugated gelatin (EnzChek Gelatinase/Collagenase Assay Kit) as MMP substrate and evaluated using 40x magnification under fluorescence microscopy. Then the fluorescent photons were analyzed with an appropriate software (ImageJ). The results were subjected to statistical analysis (2-­way ANOVA, Tukey, p<0.05) and the bioactive primers showed no significant influence on the dentin-­adhesive BS, regardless the load cycling action. According to gelatin zymography, the collagenolytic activity demonstrated that the bioactive primers were able to inhibit MMPs activity and CHX was less efficient. In situ zymography analysis, showed that the bioactive primers decreased the activity of MMPs located in adhesive interface. The data also demonstrated increased gelatinolytic activity on Control group, being higher when submitted to load cycling, and which effect was not found in the groups treated with bioactive primers. It could be concluded that although the bioactive primers did not influenced the BS of adhesive interface, they demonstrated positive results on hybrid layer degradation.
35

Efeito de diferentes soluções irrigadoras na resistência de união dentina radicular - adesivo autocondicionante

Martins, Giovana Ribeiro de [UNESP] 26 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-26Bitstream added on 2014-06-13T20:36:13Z : No. of bitstreams: 1 martins_gr_me_sjc.pdf: 3223444 bytes, checksum: 86988c1a5d4c8b8f82b29a6fd9eef209 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A restauração de dentes tratados endodonticamente continua a ser fator chave para o sucesso do tratamento. O objetivo deste estudo foi avaliar a resistência de união entre um sistema adesivo autocondicionante/cimento resinoso e a dentina intra-radicular dos terços cervical e médio, em função de diferentes protocolos de irrigação. Sessenta dentes humanos unirradiculados receberam tratamento endodôntico e foram divididos em três grupos (n = 20) de acordo com a solução irrigadora durante o preparo biomecânico: GRUPO 1 (controle): soro fisiológico; GRUPO 2: hipoclorito de sódio (NaOCl) 2,5%; e GRUPO 3: clorexidina gel (CLX) 2%. Após obturação endodôntica, os dentes foram preparados e pinos de cimento resinoso cimentados depois de diferentes tratamentos da dentina radicular do espaço para pino, de acordo com os grupos anteriores, porém subdivididos em A e B (n =10) acrescentando ou não o EDTA 17%: G1A: soro fisiológico; G1B: soro fisiológico + EDTA 17%; G2A: NaOCl 2,5%; G2B: NaOCl 2,5% + EDTA 17%; G3A: CLX gel 2%; G3B: CLX gel 2% + EDTA 17%. Todos os espécimes foram seccionados em 4 fatias (2 cervicais e 2 médias) para ensaio mecânico de extrusão por cisalhamento (push-out). Os padrões de fratura foram analisados em lupa e os dados numéricos obtidos após ensaio mecânico foram analisados estatisticamente pelo teste ANOVA. Uma amostra de cada grupo foi confeccionada para observação da interface dentina/resina em MEV. As médias (MPa), em ordem decrescente, foram: grupo 2A) 5,95; grupo 3A) 5,72; grupo 3B) 4,77; grupo 2B) 4,26; grupo 1A) 4,22; grupo 1B) 3,60. Os grupos tratados com NaOCl 2,5% e CLX gel 2% obtiveram melhores resultados do que o controle e o EDTA diminuiu a resistência de união em todos os grupos, porém sem diferenças estatisticamente significantes (P > 0,05). As médias de acordo com as regiões do canal foram:... / Besides the sucess of root canal treatment of teeth, a successful final restoration is also important for long-term clinical sucess. The influence of endodontic irrigation on bond strengths of resin cement (self-etching adhesive) to radicular dentin was investigated. Sixty extracted single-rooted human teeth were subjected to post space preparation after endodontic therapy with three different root canal irrigants (n = 20): Group 1: 0,9% sodium chloride (control); group 2: 2,5% sodium hypochlorite (NaOCl); group 3: 2% chlorhexidine gel (CHX). Post space was also treated with sodium chloride, NaOCl or CHX and subdivided into A and B (without or with 17% EDTA) (n = 10). Posts of resin cement were cemented and the specimes were sectioned into four dental slices approximately 2 mm each (2 cervical, 2 middle). They were submitted to the push-out test. The data were submitted to an analysis of variance (ANOVA) and scanning electron microscopic (SEM) analysis was performed in specimes. The mean values (MPa) obtained were: Group 2A) 5,95 > Group 3A) 5,72 > Group 3B) 4,77 > Group 2B) 4,26 > Group 1A) 4,22 > Group 1B) 3,60. The groups that used 2,5% NaOCl and 2% CHX showed highest retention, and 17% EDTA decreased bond strength to root canal dentin, however, no significant differences were found among groups (p > 0,05)...(Complete abstract click electronic access below)
36

Efeito de desinfecções sucessivas com energia de microondas na resistência de união entre dentes artificiais e resinas para bases de próteses

Chuqui, Roberta [UNESP] 28 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-28Bitstream added on 2014-06-13T18:38:57Z : No. of bitstreams: 1 chuqui_r_me_arafo.pdf: 5214724 bytes, checksum: 7fcde9af460bda49c5c01007a97620cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este estudo avaliou o efeito de desinfecções sucessivas por meio da utilização de microondas sobre a resistência de união entre dentes artificiais (incisivos centrais superiores: Biotone - DB, modelo 264 e Vivodent - DV, modelo A15) e resinas para bases (QC20 - QC, Acron MC - AC e Lucitone 550 - L). Os dentes artificiais foram posicionados em anéis de PVC (20 mm de diâmetro e 20 mm de altura) preenchidos com cera. Cada anel foi incluído em silicone por condensação para facilitar posteriormente a remoção das amostras polimerizadas. Esses moldes de silicone foram então incluídos em mufla dental com gesso. A cera foi eliminada com água em ebulição, sendo o molde preenchido com resina acrílica, manipulada e polimerizada de acordo com as instruções do fabricante. Quarenta corpos-de-prova foram obtidos para as três resinas de base com as duas marcas de dentes avaliados. Todas as amostras foram divididas aleatoriamente em quatro grupos. G1 (controle) - amostras imersas em água destilada a 37ºC por 48 horas; G2 - imersas por 48 horas e submetidas a dois ciclos de desinfecção por 6 minutos a 650 W; G3 - imersas por 48 horas em água destilada e submetidas a sete ciclos de desinfecção (um por dia) por 6 minutos a 650 W, estando as amostras imersas em água a 37ºC entre as desinfecções; G4 - imersas em água destilada por 8 dias (controle). O teste de cisalhamento foi realizado em máquina de ensaios MTS - 810 com a força aplicada na superfície palatina dos dentes em ângulo de 45º e velocidade de 0,5 mm/min. As superfícies de fratura foram observadas em lupa esteroscópica com um aumento de 10 vezes para determinar a natureza da falha (adesiva, coesiva ou mista). Adicionalmente, foi realizada microscopia eletrônica de varredura. Os dados (MPa) foram analisados utilizando ANOVA, teste de Tukey e teste t de Student (P=0,05)... / This study evaluated the effect of microwave disinfection on the bond strength of denture teeth (maxillary central incisors: Biotone - DB, model 264 and Vivodent - DV, model A15) to acrylic resins (QC20 - QC, Acron MC - AC and Lucitone 550 - L). Denture teeth were positioned within polyvinylchloride tubes (20 mm diameter and 20 mm length) filled with melted wax. The tubes were invested in silicone rubber to facilitate removal of the processed specimens from the flask. These silicone moulds were then invested in the usual denture flasks in dental stone. The wax was boiled out, the mould was packed with denture resin and polymerized according to the manufacturer's instructions. Forty specimens were formed from each of the three denture base resin with the two brands of denture teeth. All specimens were randomly divided into four groups to provide a sample size of 10. G1 (control group) - immersed in distilled water at 37ºC for 48 hours; G2 - immersed in distilled water at 37ºC for 48 hours and microwaved twice at 650W for 6 minutes; G3 - immersed in distilled water at 37ºC for 48 hours and microwaved (650 W for 6 minutes) daily for 7 days, being stored in water at 37ºC between exposures; G4 (control group) - immersed in distilled water at 37ºC for 8 days. Shear load was applied with a load testing machine at 45 degrees from the long axis of each denture tooth on the palatal surface at a crosshead speed of 0.5mm/min until fracture. Fracture surfaces were evaluated with an optical stereomicroscope under x 10 magnifications to determine the nature of the failure (adhesive, cohesive or combination). In addition, a representative sample of each experimental group was evaluated with a scanning Electron Microscopy (SEM). The data (MPa) were analyzed statistically using 3-way ANOVA, Tukey's test and Student's t test (P=0.05)...(Complete abstract, click electronic address below)
37

Avaliação da resistência adesiva à dentina tratada pela terapia fotodinâmica em dente bovino / Evaluation of the bond strength to dentin treated by photodynamic therapy in bovine tooth

Christian Giancarlo Bernal Rodriguez 17 January 2017 (has links)
A Terapia fotodinâmica (TF) é uma técnica que combina a ativação de um fotossensibilizador por luz na presença de oxigênio, produzindo radicais que induzem a morte celular dos microrganismos. Esta terapia vem sendo usada para reduzir a quantidade de microrganismos sendo um potencial antimicrobiano nos tecidos cariados em um processo restaurador direto, evitando assim o processo de cárie recidivante que pode acontecer quando não se promove a eliminação dos restos de microrganismo remanescentes após a utilização dos instrumentos rotatórios. O objetivo deste estudo in vitro foi avaliar a resistência de união de dois sistemas adesivos (condicionamento total e autocondicionante), sobre a superfície de dentina bovina, após tratamento com terapia fotodinâmica. Foi feito ensaio de microcisalhamento com o objetivo de avaliar a resistência de união. Para a realização da terapia fotodinâmica foi usado azul de metileno a 0,01% e duas fontes de luz diferentes, laser vermelho (660 nm) e LED (645-630 nm), com parâmetros já testados em estudos anteriores e, atualmente, utilizados na clinica odontológica. Para avaliar a resistência de união foi utilizado ensaio mecânico de microcisalhamento e, para isso, se utilizou sessenta discos de dentina, obtidos a partir de sessenta incisivos centrais bovino íntegros. Após o desgaste da dentina, as amostras foram dividas aleatoriamente em 6 grupos, sendo n=10 para o ensaio de microcisalhamento (G1: adesivo autocondicionante Single Bond Universal (USB) sem PDT, G2: PDT com laser + USB, G3: PDT com LED + USB; G4: adesivo de condicionamento total com Adper Single Bond 2 (ASB) sem PDT; G5: PDT com laser + ASB¸ G6: PDT com LED + ASB). Em cada amostra foram confeccionados 03 cilindros de resina composta, os quais foram submetidos à avaliação de microcisalhamento (1 mm/min); após armazenamento em saliva artificial por 24 horas. Após este teste, as amostras foram levadas em lupa estereoscópica (40x) para análise do padrão de fratura. Os resultados do teste de resistência de união foram tabulados e submetidos ao teste ANOVA dois fatores (adesivo e tratamento) e Tukey adotando-se um nível de significância de 5%. Quanto à resistência de união, não houve diferença significativa entre os 6 grupos analisados. Houve predominância de padrão de fratura do tipo adesiva. Com base nos resultados e nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que não existe alteração na força de adesão da resina na dentina hígida após tratamento com PDT. / Photodynamic Therapy (PDT) is a technique that combines the activation of a photosensitizer by light in the presence of oxygen, producing radicals that induce cell death of the microorganisms. This therapy has been used to reduce the amount of microorganisms being an antimicrobial potential in the decayed tissues in a direct restorative process, thus avoiding the process of recurrent caries that can happen when the elimination of remaining remains of microorganism after the use of the instruments is not promoted. The objective of this in vitro study was to evaluate the bond strength and morphology of the hybrid layer of two adhesive systems (Self-etch and total etch) on the bovine dentin surface, after treatment with photodynamic therapy. A micro-shear test was performed in order to evaluate the bond strength. To perform the photodynamic therapy, 0.01% methylene blue and two different light sources, red laser (660 nm) and LED (645-630 nm) were used, with parameters already tested in previous studies and currently used in the dental clinic. In order to evaluate the bond strength, a microshear bond strenght test was used. For this purpose, sixty dentin disks were obtained from sixty complete central incisors. After dentin wear, the samples were randomly divided into 6 groups, with n = 10 for the micro bond strenght test (G1: Self-etch adhesive, single bond Universal (USB) without PDT, G2: PDT with laser + USB, G3: PDT with LED + USB; G4: total etch adhesive Single Bond 2 (ASB) without PDT; G5: PDT with laser + ASB¸ G6: PDT with LED + ASB). In each sample, 03 cylinders of composite resin were made, which were submitted to the evaluation of micro-shear strenght test (1 mm / min); after storage in artificial saliva for 24 hours. After this test, the samples were taken in a stereoscopic magnifying glass (40x) for analysis of the fracture pattern. The results of the Microshear bond strength test were tabulated and submitted to ANOVA two-factor test (adhesive and treatment) and Tukey adopting a significance level of 5%. Regarding the bond strength, there was no significant difference between the 6 groups analyzed. There was a predominance of an adhesive type fracture pattern. Based on the results and the irradiation parameters used in this study, it can be concluded that there is no alteration in the adhesion strenght of the resin in a healthy dentin after treatment with PDT.
38

Resistência de união da interface coping cerâmico pilar de implante variando o agente cimentante antes e após ciclagem térmica / Bond strength of the ceramic coping-implant abutment interface varying luting agent before and after thermal cycling

Washington dos Reis Leite 25 October 2010 (has links)
Objetivo: O objetivo do presente estudo foi avaliar a resistência de união da interface coping cerâmico-pilar de implante variando o agente cimentante antes e após ciclagem térmica. Material e métodos: Foram utilizados quarenta conjuntos de copings cerâmicos e.max - pilar sólido 5.5/ análogo regular, sendo estes divididos aleatoriamente de acordo com o agente cimentante (n=10): (OZ) óxido de zinco sem eugenol; (FZ) fosfato de zinco; (CIV) ionômero de vidro modificado por resina; (RES) resinoso autopolimerizável. O teste de resistência da união à tração foi executado em uma máquina de ensaios universal (Versat 2000-Panambra), com velocidade de 1,0mm/min, antes e após ensaio de envelhecimento por ciclagem térmica. Os resultados foram submetidos ao teste de normalidade e posteriormente a ANOVA (two-way) e teste de Tukey, com nível de significância de 5%. Resultados: Antes da ciclagem térmica, os valores variaram entre o mínimo de 50,77N (OZ) e o máximo de 240,21N (CIV). Não foi observada diferença entre OZ e FZ (60,16N), nem entre CIV e RES (230,36N). Após a ciclagem térmica, os valores foram de no mínimo 3,5N (OZ) e máximo de 330,66N (RES). OZ apresentou resultados estatísticamente inferiores se comparado aos demais, enquanto RES obteve resultados estatísticamente superiores em relação aos demais agentes cimentantes, FZ (90,58N) e CIV (280,43N) apresentaram resultados intermediários. Conclusões: O cimento de óxido de zinco sem eugenol foi associado ao pior desempenho comparado aos demais agentes avaliados antes e após a ciclagem. Antes da ciclagem térmica o maior valor médio obtido foi do ionômero de vidro, enquanto que após a ciclagem o maior valor médio foi do cimento resinoso. O envelhecimento das amostras promoveu inversão dos resultados do ionômero e resinoso, com melhor resultado mecânico para o cimento resinoso. / Objective: The aim of the present study was to evaluate the bond strength of the ceramic coping-abutment implant interface according to the luting agent, before and after thermal cycling. Methods: A total of forty sets of ceramic copings (IPS e.max) and solid pillar 5.5/ regular analogue were divided according to the luting agent (n=10): (OZ) zinc oxide with no eugenol; (ZP) zinc phosphate, (CIV) resin modified glass ionomer, (RES) adhesive resin cement. Tensile bond strength test was performed using a universal testing machine (2000-Versat Panambra) with a speed of 1.0mm/min, before and after thermal cycling. Results were submitted to normality test and then analyzed by ANOVA and Tukey test with significance level of 5%. Results: Prior to thermal cycling, values ranged from 50.77N (OZ) to 240.21N (CIV). No difference was observed between OZ and FZ (60.16N), nor between CIV and RES (230.36N). After thermal cycling, values ranged between 3.5N (OZ) and 330.66N (RES). OZ showed statistically lower mean values compared to the others. RES presented statistically higher mean values in comparison to the other luting agents. FZ (90.58N) and CIV (280.43N) showed intermediate results. Conclusions: Zinc oxide with no eugenol was associated with the worst performance compared to the other agents after thermal cycling. Before thermal cycling the highest mean value was obtained for the glass ionomer. However, after this step, adhesive resin cement showed the highest mean value of bond strength. The sample aging inverted results between ionomer and resin cement, with better mechanical performance for the resin cement.
39

Influência do protocolo de secagem dos canais radiculares na resistência de união e selamento apical de obturações com cimentos com silicato de cálcio e com hidróxido de cálcio / Influence of drying protocols in the bond strength and apical sealing of teeth filled with calcium silicate and calcium hydroxide sealers

Adrianne Calixto Freire de Paula 01 October 2014 (has links)
O propósito deste estudo foi avaliar a influência de protocolos de secagem do canal na resistência de união (RU) e no selamento apical (SA) de obturações com AH Plus, Sealapex e MTA Fillapex. Cento e cinquenta e seis raízes de caninos superiores foram submetidas à biomecânica com sistema Reciproc (R50) e distribuídas de acordo com o protocolo de secagem (PS): GI- cones de papel; GII- álcool isopropílico 70% + aspiração com pontas NaviTips; GIII- etanol 95% + cones de papel; GIV- EndoVac + cone de papel. Cada grupo foi dividido em subgrupos conforme o cimento obturador: A- AH Plus; B- Sealapex; C- MTA Fillapex. Utilizou-se para todos os espécimes técnica de obturação do cone único. As raízes de cada subgrupo foram destinadas à avaliação do SA (n=8) e RU (n=5), por meio do método de filtração de fluidos (FF) e push-out (PO), respectivamente. Para o PO as raízes foram seccionadas e um slice de cada terço submetido ao teste e à análise do tipo de falha. Os dados foram submetidos aos testes Anova two-way e three-way e Tukey por meio dos software SPSS 15.0 e SigmaStat 3.5 (&alpha;=5%). Os resultados da FF mostraram diferença significante entre os cimentos MTA e Sealapex (p<0,05). O SA não sofreu influência dos protocolos. Na RU não houve diferença entre os terços do canal (p>0,05), mas houve entre os cimentos (p<0,05), protocolos (p<0,05) e na interação cimentos/protocolos (p<0,05). O AH Plus (1,39±0,60) apresentou os maiores valores de RU em relação ao Sealapex (0,83±0,33) e MTA (0,76±0,34). Espécimes secos com álcool isopropílico proporcionaram aos cimentos testados maior resistência de união que quando secos com etanol (p=0,005) e EndoVac (p=0,002). Canais secos com etanol não influenciaram os cimentos. O uso de cones de papel, EndoVac e álcool isopropílico e obturação com AH Plus apresentaram os maiores valores RU que os demais cimentos. Concluiu-se que a infiltração ocorrida com o AH Plus foi semelhante a dos demais cimentos. O AH Plus apresentou os maiores valores de RU. No terço cervical houve predominância de falhas coesivas e de mistas nos demais terços. / The purpose of this study was to evaluate the influence of drying protocols in the bond strength (BS) and in the apical sealing (AS) of teeth filled with AH Plus, Sealapex and MTA Fillapex. One hundred and fifty-six roots of maxillary canines were subjected to biomechanical preparation with Reciproc (R50) and hand out according to the drying protocol (DP): GI-paper points; GII-70% isopropyl alcohol + aspiration with NaviTip points; GIII-95% ethanol + paper points; GIV-EndoVac + paper points. Each group was divided into subgroups according the used sealer: A- AH Plus; B- Sealapex; C- Fillapex MTA. The single cone obturation technique was used for all the samples. The roots of each subgroup were intended for the evaluation of the AS (n = 8) and the BS (n = 5) by using the fluid filtration (FF) and the push-out (PO) methods, respectively. Regarding the PO, the roots were sectioned and a single slice from each third was subjected to testing and also analysed for the type of failure. Data was submitted to the Tukey, two-way and the three-way variance analysis (ANOVA) resorting the SPSS 15.0 and the SigmaStat 3.5 (&alpha;= 5%) software. The results of the FF revealed a statistical significant difference between the MTA and the Sealapex (p <0.05) sealers. The AS showed no influence of the protocols. When it comes to the BS there was no statistical significant difference between the canal thirds (p> 0.05), but there was between the sealers (p <0.05), the protocols (p <0.05) and in the interaction between the sealers and the protocols (p <0.05). AH Plus (1.39 ± 0.60) revealed the highest BS comparing with Sealapex (0.83 ± 0.33) and MTA (0.76 ± 0.34). The specimens in which the isopropyl alcohol was used, had the highest bond strength results for the sealers, comparing with ethanol (p = 0.005) and EndoVac (p = 0.002). In the canals that ethanol was used, no alteration of the sealer was noticed. The use of paper points, EndoVac and isopropyl alcohol and filling with AH Plus revealed the highest BS values comparing with the other sealers. It was concluded that the infiltration that occurred with AH Plus was similar with the other sealers. AH Plus showed the highest BS. In the cervical third there was preponderance of cohesive failures, and in the other thirds the mixed type of failure.
40

Resistência de união de diferentes zircônias envelhecidas / Bonding strength of different aged zirconia

Gallina, Bernardo Luiz 02 March 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-05-28T19:18:23Z No. of bitstreams: 2 Bernardo Luiz Gallina.pdf: 1455679 bytes, checksum: 0664c2eccf6aef896ff0831448f3e489 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-28T19:18:23Z (GMT). No. of bitstreams: 2 Bernardo Luiz Gallina.pdf: 1455679 bytes, checksum: 0664c2eccf6aef896ff0831448f3e489 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-02 / Zirconia has been extensively researched due to its biocompatibility, mechanical resistance and having an aesthetic property, being widely used in dentistry. Prettau Anterior zirconia presents superior esthetics for anterior region, when compared to other zirconia. The objective of this study was to evaluate the bond strength of two Zirconias with different compositions.For this purpose, twenty-two (22) blocks were made and cut with 3x5x10mm of each of the evaluated materials: Zirconia ICE Zirkon Translucent (ZT) and ZirconiaPrettau Anterior (ZPA). The specimens were made using resin cement RelyX Unicem U200 with a vinylpolysiloxane matrix assistence. Then, 11 blocks of each group were separated in two storage times: 1 and 90 days of storage in distilled water at 37 ° C, totaling n = 11. The Micro-shearing test was performed at a speed of 0.5 mm / min on the Universal testing machine. The samples were also submitted to fracture analysis and analysis by scanning electron microscopy. The results were submitted to the Shapiro Wilk test, Analysis of Variance ANOVA (two-way) and then to Tukey's test, p <0.01. The means obtained for the group aged in 1 day were: 7.56 (+1.02) for ZT, 9.38 (+1.22) for ZPA. And for the samples that aged 90 days were: 0.47 (+1.02) for ZT, 1.74 (+0.58) for ZPA. Statistically significant differences were observed for the factors: ceramic type and aging time. According to the obtained results, it was possible to observe that Zirconia Prettau Anterior showed results statistically superior to Zirconia ICE Zirkon Translucent, in both aging times evaluated. / A zircônia vem sendo pesquisada de maneira exaustiva devido a sua biocompatibilidade, resistência mecânica e por sua estética. A zircônia Prettau Anterior apresenta estética superior para região anterior, quando comparada a outras zircônias. O objetivo desse trabalho foi avaliar comparativamente a resistência de união de duas Zircônias com composições diferentes. Para isso, foram confeccionados vinte e dois (22) blocos foram cortados com 3x5x10mm de cada um dos materiais avaliados: Zircônia ICE Zirkon Translucent (ZT) e Zircônia Prettau Anterior(ZPA). Os corpos de prova foram confeccionados usando cimento resinoso RelyX Unicem U200 com auxílio de uma matriz de silicone por adição Express. Onze blocos de cada grupo foram destinados para cada um dos tempos de armazenamento (24 horas e 90 dias) em água destilada a 37oC. O teste de microcisalhamento foi realizado a uma velocidade de 0.5mm/min em máquina de ensaio Universal EMIC DL-200 MF. As amostras foram submetidas também à análise de fratura e análise em microscopia eletrônica de varredura. Os resultados obtidos foram submetidos ao teste Shapiro Wilk, Análise de Variância ANOVA (two-way) e, em seguida, ao teste de Tukey, p < 0,01. As médias obtidas para o grupo envelhecido em 1 dia foram: 7,56(+1,02) MPa para ZT, 9,38(+1,22) MPa para ZPA, e para as amostras envelhecidas por 90 dias foram: 0,47(+1,02) MPa para ZT, 1,74(+0,58) MPa para ZPA. Foram observadas diferenças estatisticamente significantes para os fatores tipo de cerâmica e tempo de envelhecimento. De acordo com os resultados obtidos foi possível observar que a Zircônia Prettau Anterior mostrou resultados estatisticamente superiores a Zircônia ICE Zirkon Translucent, nos dois tempos de envelhecimento avaliados.

Page generated in 0.1452 seconds