• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 720
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 5
  • 5
  • 3
  • 1
  • Tagged with
  • 736
  • 320
  • 285
  • 123
  • 111
  • 100
  • 91
  • 90
  • 89
  • 87
  • 78
  • 75
  • 74
  • 73
  • 71
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeitos a curto prazo da ventilação mecânica com dois níveis de PEEP (BiPEEP) em pacientes com síndrome da angústia respiratória aguda

Fontela, Paula Caitano January 2017 (has links)
Resumo não disponível.
22

Estudo comparativo do conforto e efeitos adversos de interfaces para ventilação não invasiva em voluntários sadios / Comparative study of the comfort and adverse effect of interfaces for not invasive ventilation in healthy volunteers

Reis, Ricardo January 2006 (has links)
REIS, Ricardo Coelho. Estudo comparativo do conforto e efeitos adversos de interfaces para ventilação não invasiva em voluntários sadios. 2006. 109 f. Dissertação (Mestrado em Medicina)-Universidade Federal do Ceará, Fortaleza, 2006. / Submitted by denise santos (denise.santos@ufc.br) on 2011-10-27T12:35:49Z No. of bitstreams: 1 2006_dis_rcreis.pdf: 2198513 bytes, checksum: ea0f7cb735af3724bf87dfca83c3c16b (MD5) / Approved for entry into archive by Eliene Nascimento(elienegvn@hotmail.com) on 2011-10-31T17:23:14Z (GMT) No. of bitstreams: 1 2006_dis_rcreis.pdf: 2198513 bytes, checksum: ea0f7cb735af3724bf87dfca83c3c16b (MD5) / Made available in DSpace on 2011-10-31T17:23:14Z (GMT). No. of bitstreams: 1 2006_dis_rcreis.pdf: 2198513 bytes, checksum: ea0f7cb735af3724bf87dfca83c3c16b (MD5) Previous issue date: 2006 / Rationale: Non-invasive ventilation (NIV) is defined as a ventilatory support technique using an interface (usually a mask) instead of tracheal intubation to adapt the patient’s respiratory system to the ventilator. Although it is as efficacious as the invasive method in terms of improving gas exchange in patients with respiratory failure due to various etiologies, it remains associated with considerable failure rates. Despite the association between interface and low tolerance to NIV, few studies have been published evaluating the efficacy and safety of each type of interface. interfaces are best studied on healthy subjects avoiding the interference of confounding factors related to respiratory failure. Objective: To evaluate and compare three types of masks used as NIV interface on healthy volunteers with regard to frequency and type of adverse events and level of comfort. Method: A randomized, crossover clinical trial was conducted to evaluate and compare nasal (N), facial (F), and total face (TF) masks adapted to healthy volunteers using a flow generator ventilator with a circuit exhalation valve. The three masks were tested on all subjects in random sequence during 10 minutes each, equally divided between two levels of expiratory and inspiratory positive airway pressure (EPAP; IPAP) in bilevel ventilation: a low-pressure (LoP) setup (IPAP: 11cmH2O; EPAP: 6cmH2O) and a moderate to high-pressure (MoHiP) setup (IPAP=15cmH2O; EPAP=10cmH2O). At the end of each 5-min period, the subjects were given a standardized written questionnaire on adverse events including questions about uncomfortable pressure and pain at contact points between mask and face, unpleasant perception of air leaks, nasal and oral mucosal dryness and claustrophobia. They also recorded sensations of comfort on a 10-cm visual analogical scale (10=absence of discomfort; 0=maximum discomfort). A 10-min interval of spontaneous, mask-free breathing was allowed between each period of NIV. The respiratory rate (RR), tidal volume (TV), pulse oxymetry (SpO2) and end-tidal CO2 volume (EtCO2), measured between mask and exhalation valve, were monitored during the entire protocol. While categorized variables were analyzed with Pearson’s Chi-square test, Fisher’s exact test and McNemar’s test, continuous variables were analyzed with ANOVA and least-squares regression. Results: The study included 24 healthy volunteers (12 women) aged 18 to 35 (mean age: 25.7 years). The following was observed with regard to adverse events while using the LoP setup: a) The incidence of one or more adverse events by subject was 91.7% for N and TF and 95.8% for F; b) The number of adverse events per subject was smaller for N than for F (3.58 vs. 5.0; p=0.002) or TF (3.58 vs. 4.71; p=0.03); c) The most frequently reported adverse event was “mask pressure” (N=54.2%; F=66.7%; FT=66.7%); d) Pain at points of mask contact was less frequently reported for TF than for F (37.5% vs. 66.7%; p=0.01), but no significant difference was observed between TF and N; e) The incidence of unpleasant air leak perception around the eyes or mouth was lower for TF than for N (41.7% vs. 75%; p=0.03) but no significant difference was observed between N and F; f) Complaints of nasal or oral dryness were much less frequent for N than for F (25% vs. 62.5%; p=0.01) or TF (25% vs. 75%; p<0.001); g) Claustrophobia was more frequently reported for TF than for N (33.3% vs. 8.3%; p=0.07). The higher airway pressure of the MoHiP setup resulted in: a) The incidence of one or more adverse events per subject remained high (95.8% for both N and TF; 100% for F); b) On the average, N continued to be associated with the lowest number of adverse events per subject, the difference between N and F being statistically significant (4.75 vs. 6.04; p=0.009); c) Mask pressure remained the most common complaint (N=62.5%; F=70.8%; FT=75%); d) No significant difference was observed concerning pain; e) Reports of unpleasant air leak perception increased more for F than for TF (83.3% vs. 54.2%; p=0.09); f) N continued to be associated with the lowest incidence of dryness (N=41.7% vs. F=66.7%; p=0.03; and N=41.7% vs. TF=79.2%, p=0.02); g) The incidence of claustrophobia remained higher for TF than for N, though not statistically so (33.3% vs. 8.3%; p=0.07); h) On the average, pressure augmentation induced a higher number of adverse events per subject in all 3 mask types. The increase was statistically significant in the case of N (3.58 vs. 4.75; p=0.003) and F (5.0 vs. 6.04; p=0.007) and tended to be so for TF (4.71 vs. 5.33; p=0.07); i) No significant difference was observed between the masks with regard to comfort, but the MoHiP setup was reportedly less comfortable than the LoP setup for all mask types: N (7.54 vs. 7.1; p=0.01), F (7.50 vs. 6.54; p<0.001) and TF (7.25 vs. 6.50; p=0.001). Physiological variations observed during the protocol could not account for the adverse events or comfort sensation reported. Interestingly, the CO2 curve remained undetected by the capnograph while using TF, probably because the exhaled CO2 was completely eliminated through orifices in the mask. Conclusions: All three mask types presented a high incidence of adverse events in healthy volunteers. The nasal (N) mask was associated with a lower mean number of adverse events per subject, especially with regard to dryness. Although the total face (TF) mask seemed to be associated with fewer reports of pain and with a lower incidence of unpleasant air leak perception, claustrophobia was also more frequently reported. The masks were equally efficacious in terms of comfort. Higher pressure levels in the bilevel mode were associated with increased reports of discomfort and adverse events in healthy volunteers. / Introdução: A Ventilação Não Invasiva (VNI) consiste na oferta de suporte ventilatório sem uso de prótese traqueal, através de uma interface (usualmente uma máscara) adaptada entre o ventilador e o paciente. Embora a VNI apresente eficácia semelhante ao método invasivo em otimizar a troca gasosa de pacientes com insuficiência respiratória de várias etiologias, ainda há uma taxa de insucesso considerável desta modalidade. A despeito do fato de que a intolerância à interface é um importante fator associado à falha do procedimento, existem poucos trabalhos na literatura comparando diferentes dispositivos. Assim, estudos que avaliem a eficácia e a segurança e que comparem diferentes interfaces são necessários. A utilização de voluntários sadios exibe a vantagem de eliminar os sintomas da insuficiência respiratória que podem prejudicar uma avaliação mais específica da interface. Objetivos: Avaliar e comparar três tipos de máscaras para VNI, em voluntários sadios, quanto à freqüência e tipos de efeitos adversos e quanto ao nível de conforto. Casuística e Método: O estudo consistiu em um ensaio clínico randomizado do tipo crossover comparando as máscaras nasal (N), facial (F) e facial total (FT), em ventilador gerador de fluxo com orifício exalatório no circuito. Cada voluntário usava as três interfaces em uma seqüência randomizada. A VNI era aplicada por tempo total de 10 minutos para cada interface. Durante este período, dois níveis de pressão inspiratória e expiratória (IPAP e EPAP) no modo de ventilação bilevel eram aplicados, por 5 minutos, com cada máscara. Foi testado um nível baixo de pressão (Pbx) com IPAP de 11cmH2O e EPAP de 6cmH2O e um nível moderado a alto de pressão (Pma) com IPAP de 15cmH2O e EPAP de 10cmH2O. Ao final de cada período de 5 minutos, era aplicado ao voluntário questionário padronizado de efeitos adversos das interfaces, incluindo dor em vários pontos de pressão das máscaras, percepção incômoda de vazamentos, sensação de ressecamento nasal e oral e claustrofobia. O voluntário também indicava seu nível de conforto (em uso da interface) através de uma Escala Analógica Visual de 10 cm (EAV) (sendo zero o máximo desconforto e dez a ausência de desconforto). Havia um intervalo de 10 minutos em respiração espontânea sem máscara entre cada período de VNI. Durante todo o protocolo, foram monitorizados freqüência respiratória (f), Volume Corrente (VC), Oximetria de pulso (SpO2) e Capnografia (EtCO2) instalada entre a máscara e o orifício exalatório. Para a análise comparativa das variáveis categorizadas, foram utilizados os testes qui-quadrado de Pearson, exato de Fisher e Mcnemar e para as variáveis quantitativas foram utilizados os testes ANOVA e dos mínimos quadrados. Resultados: Foram avaliados 24 voluntários sadios (12 mulheres) com idade entre 18 e 35 anos (média de 25,7). Quanto aos efeitos adversos e considerando o nível de pressão mais baixo (Pbx) observou-se 1. A incidência de pelo menos um efeito foi de 91,7% para N e FT e 95,8% para F. 2. A máscara N teve média de efeitos adversos por paciente menor do que a F (3,58 x 5,0 p=0,002) e do que a FT (3,58 x 4,71 p=0,03). 3. O efeito adverso com maior incidência nas três interfaces foi “pressão da máscara” (N=54,2% F=66,7% e FT=66,7%). 4. Dor nos pontos de pressão foi significativamente menor com a FT do que com a F (37,5% x 66,7% p=0,01), sem diferença em relação à N. 5. A incidência de percepção incômoda de vazamentos (olhos/boca) foi menor com a FT do que com a N (41,7% x 75% p=0,03) e sem diferença significativa entre a N e a F. 6. Queixas de ressecamentos (nasal/oral) foram bem menos freqüentes com a interface nasal tanto em relação à facial (25% x 62,5% p= 0,01) quanto à facial total (25% x 75% p<0,001). 7. Em relação à claustrofobia, a máscara facial total apresentou uma tendência maior do que a nasal (33,3% x 8,3% p= 0,07). Considerando as mesmas variáveis, ao se incrementar a pressão, verificou-se que: 1. A incidência de efeitos adversos permaneceu alta, sendo 95,8% para N e FT e 100% para F. 2. A média de efeitos adversos por voluntário na máscara nasal permaneceu menor, sendo estatisticamente significativa em relação à facial (4,75 x 6,04 p= 0,009). 3. “Pressão da máscara” continuou sendo o efeito adverso mais freqüente nas três interfaces (N=62,5% F=70,8% FT=75%). 4. Não houve mais diferença entre as máscaras com relação à dor nos pontos de pressão. 5. Com relação aos vazamentos incômodos, houve apenas tendência de piora em F comparando-se com FT (83,3% x 54,2% p= 0,09). 6. Ressecamentos permaneceram menos freqüentes na máscara nasal, sendo N (41,7%) x F (66,7%) p= 0,03 e N (41,7%) x FT (79,2%) p=0,02. 7. Maior tendência à claustrofobia persistiu na máscara FT em relação à N (33,3% x 8,3% p= 0,07). 8. O incremento da pressão aumentou a média de efeitos adversos nas três interfaces, sendo estatisticamente significativo na máscara nasal (3,58 x 4,75 p=0,003) e na facial (5,0 x 6,04 p= 0,007) e exibindo tendência na facial total (4,71 x 5,33 p=0,07). 9. Em relação à EAV de conforto, foi observado menos conforto com Pma em relação à Pbx nas três interfaces, sendo N (7,54 x 7,13 p=0,01), F (7,50 x 6,54 p<0,001) e FT (7,25 x 6,50 p=0,001), sem diferença significativa entre as mesmas. Não houve variações significativas com relação aos parâmetros fisiológicos que pudessem influenciar o estudo comparativo dos efeitos adversos e conforto das interfaces. Não houve detecção de curva pelo capnógrafo quando se utilizou a máscara facial total, evidenciando a completa eliminação do CO2 pelos orifícios exalatórios desta interface. Conclusão: As três interfaces apresentaram alta incidência de efeitos adversos em voluntários sadios. A máscara nasal apresentou média de efeitos adversos por voluntário menor do que as outras duas interfaces, destacando-se menor incidência de ressecamentos. A máscara facial total parece estar associada a menos queixas de dor e de percepção incômoda de vazamentos, porém exibe maior tendência à claustrofobia em comparação às outras duas interfaces. As três interfaces apresentaram um bom nível de conforto, sem diferença significativa entre elas. O aumento dos níveis de pressão no modo bilevel diminuiu o conforto e aumentou os efeitos adversos relatados pelos voluntários sadios nas três interfaces.
23

Influência do biofeedback respiratório associado ao padrão Quiet Breathing sobre a função pulmonar e hábitos de respiradores bucais funcionais / Influence of respiratory biofeedback associated with a quiet breathing pattern on the pulmonary function and habits of functional mouth breathers

Barbiero, Eliane de Fáveri Franqui [UNIFESP] 30 January 2008 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:22Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-01-30. Added 1 bitstream(s) on 2015-08-11T03:26:36Z : No. of bitstreams: 1 Publico-Tese%20Eliane%20de%20Faveri%20Franqui%20Barbiero.pdf: 232362 bytes, checksum: 4e6a634c0f3442d900fd4366b50e1750 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Objetivos: Avaliar os efeitos da utilização do biofeedback respiratório (BR) associado ao padrão quiet breathing sobre a perimetria torácica, função pulmonar, força dos músculos respiratórios e os seguintes hábitos de respiradores bucais funcionais (RBF): vigília de boca aberta, boca aberta durante o sono, baba no travesseiro, despertar difícil, ronco e sono inquieto. Métodos: Foram avaliadas 20 crianças RBF, as quais foram submetidas a 15 sessões de BR, por meio do biofeedback pletsmovent (MICROHARD® V1.0), o qual proporciona o biofeedback dos movimentos tóracoabdominais. Perimetria torácica, espirometria e medidas das pressões respiratórias máximas estáticas foram realizadas antes e após a terapia. Questões respondidas pelos responsáveis foram utilizadas para avaliar os hábitos dos RBF. Os dados foram analisados por meio de teste t de Student para dados pareados e testes não paramétricos. Resultados: O uso do BR associado ao padrão quiet breathing não produziu alterações significativas na perimetria torácica e nos valores de volume expiratório forçado no primeiro segundo (VEF1), capacidade vital forçada (CVF), pico de fluxo expiratório (PFE), índice de Tiffeneau (IT) e na pressão expiratória máxima (PEmax). Entretanto, a pressão inspiratória máxima (PImax) apresentou diferença estatisticamente significativa (-53,6 ± 2,9 cmH2O vs. -65,0 ± 6,0 cmH2O; p < 0,05) e ocorreram mudanças significativas nos hábitos avaliados. Conclusão: Os resultados permitem concluir que o BR associado ao padrão quiet breathing melhora a força da musculatura inspiratória e hábitos em RBF, podendo ser, portanto, utilizado como uma das formas de terapia nestes indivíduos. / Objective: To evaluate the effects of the use of respiratory biofeedback (RB) associated with quiet breathing on the thoracic perimetry, pulmonary function, force of the respiratory muscles and the following habits of functional mouth breathing (FMB): vigil of open mouth, sleeps of open mouth, dribbles in the pillow, difficult wakening, snore and restless sleep. Methods: It had been evaluated 20 FMB children, which had been submitted to 15 sessions of RB, through biofeedback pletsmovent (MICROHARD® V1.0), which provides the biofeedback of the thoraco-abdominal movements. Thoracic perimetry, spirometry and measures of the maximum static respiratory pressures were determined before and after the therapy. Subjects answered by the responsible ware used to evaluate the habits of FMB. paired Student’s t test and nonparametric tests had been used for analysis of the data. Results: The use of the RB associated with quiet breathing didn’t produce significant alterations in the thoracic perimetry and in the values of forced expiratory volume in the first second (FEV1), forced vital capacity (FVC), peak of expiratory flow (PEF), Tiffeneau indice (TI) and in the maximal expiratory pressure (PEmax). However, the maximal inspiratory pressure (PImax) presented significant statistic difference (-53.6 ± 2.9 cmH2O vs. -65.0 ± 6.0 cmH2O; p < 0.05) and happened significant changes in the evaluated habits. Conclusion: The results allow to conclude that the RB associated with quiet breathing improves the force of the inspiratory muscles and habits in FMB, therefore, it can be used as form of therapy in these individuals. / TEDE / BV UNIFESP: Teses e dissertações
24

Efeitos a curto prazo da ventilação mecânica com dois níveis de PEEP (BiPEEP) em pacientes com síndrome da angústia respiratória aguda

Fontela, Paula Caitano January 2017 (has links)
Resumo não disponível.
25

Efeitos a curto prazo da ventilação mecânica com dois níveis de PEEP (BiPEEP) em pacientes com síndrome da angústia respiratória aguda

Fontela, Paula Caitano January 2017 (has links)
Resumo não disponível.
26

Analise de volumes parciais do tronco durante a respiração por videogrametria / Analysis of trunk partial volumes during the breath by videogrametria

Loula, Carla Maia Aguiar 28 July 2005 (has links)
Orientador: Ricardo Machado Leite de Barros / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Educação Fisica / Made available in DSpace on 2018-08-04T22:05:00Z (GMT). No. of bitstreams: 1 Loula_CarlaMaiaAguiar_M.pdf: 1615820 bytes, checksum: 09f1d59f9fd80bcffce16a5a606374be (MD5) Previous issue date: 2005 / Resumo: Este trabalho tem como finalidade propor e avaliar uma metodologia para cálculo da variação de volume no tronco durante a ventilação humana. Para isso foi utilizado um sistema de análise cinemática tridimensional de movimentos (Dvideow) para obter a descrição das coordenadas 3D de 30 marcadores fixados sobre referências anatômicas na caixa torácica e abdômen durante a ventilação. As medidas de volume foram calculadas a partir de um modelo geométrico de representação do tronco que o subdivide em 8 dodecaedros irregulares correspondendo aos volumes parciais do tronco (tórax superior, TX-S; tórax inferior, TX-I; abdômen superior, AB-S e abdômen inferior, AB-I). Para avaliação da metodologia foram realizados três experimentos; um compara os volumes obtidos através da videogrametria com os volumes de ar trocados entre os pulmões e o meio externo, medido através da espirometria; o segundo experimento analisa a reprodutibilidade do método proposto. Um terceiro experimento foi realizado para verificar a contribuição dos compartimentos para a variação do volume total no tronco. Para tanto foram analisados os volumes do tronco de 13 voluntários em duas manobras ventilatórias distintas, volume corrente (VC) e volume máximo (VM). Na comparação entre a videogrametria e espirometria, os resultados mostraram um coeficiente de correlação de 0.9938 entre as medidas de ar obtido pela espirometria e a variação do volume do tronco medida pela videogrametria. Contudo, os valores absolutos diferiram em até 0.6 litros na inspiração profunda. No teste de reposicionamento de marcadores encontrou-se uma variabilidade da ordem de 3% do volume total médio. Na análise da contribuição dos compartimentos para o volume total do tronco foi observada uma contribuição maior do tórax em relação ao abdômen nas duas manobras estudadas. Na análise dos compartimentos TX-S, TX-I, AB-S e AB-I os compartimentos TX-I e AB-S tiveram participação mais significativa que o TX-S, enquanto que o AB-I teve uma contribuição negativa para o volume total na manobra de VC. Na manobra de VM os resultados demonstraram uma contribuição semelhante entre os compartimentos TX-S, TX-I, AB-S, enquanto o AB-I, apresentou oposição de fase em alguns voluntários. De maneira geral os resultados evidenciaram sinais correlacionados entre as variações de volume do tronco e o sinal ventilatório e a videogrametria demonstrou ser um método eficiente na análise da contribuição dos compartimentos para a variação de volume total no tronco / Abstract: This work has the objective of proposing and evaluating a methodology to calculate the trunk volume variation during human respiration. Thereunto a three-dimensional movement kinematical analysis system (Dvideow) was used to obtain the 3D coordinate description of 30 markers attached over anatomical references in the rib cage and abdomen during breathing. The volume measures were calculated from a geometrical representation model for the trunk, which subdivides it in 8 irregular dodecahedrons, corresponding to partial volumes of the trunk. To evaluate the methodology, three experiments were done: one that compares the trunk volumes obtained by videogrammetry with the volume of air exchanged between the lungs and external medium, measured by spirometry; and a second analyzes the reproducibility of the proposed method. A third experiment was executed to verify the compartments contributions to the total trunk volume variation examining this variation in 13 volunteers in two distinct ventilatory maneuvers, tidal volume and maximum volume. In the comparison between videogrammetry and spirometry, results exhibit a correlation coefficient of 0.9938, however, absolute values differ up to 0.6 liters in deep inspiration. In the reproducibility test, it was determined a variability around 3% of the mean total volume. In the compartment contribution analysis, a greater contribution from the rib cage relative to the abdomen was observed in the two studied maneuvers. In the analysis of the subdivision of rib cage and abdomen compartments, the lower rib cage and the upper abdomen had a more significant participation that the upper rib cage, while the lower abdomen had a negative contribution to the total volume during tidal volume maneuvers. In the maximum volume maneuver, results demonstrate a similar contribution for the upper ribcage, lower ribcage and upper abdomen, while the lower abdomen, presented negative contribution. In the overall, results reveal correlated signals between the trunk volume variation and the ventilatory signal, and videogrammetry proved to be an efficient method for the analysis of compartment contribution for total trunk volume variation / Mestrado / Biodinamica do Movimento Humano / Mestre em Educação Física
27

Desfecho do paciente de ventilação mecânica prolongada após alta da Unidade de Terapia Intensiva

Potrichi, Ines Cristina Pereira 30 June 2016 (has links)
Made available in DSpace on 2019-03-30T00:06:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2016-06-30 / Introduction. Given the advances in technology, the skilled human resources, and the fight for life of critically ill patients, the Intensive Care Unit (ICU) can develop a population of ¿chronically and critically ill patients". Their main characteristic is the dependence on Prolonged Mechanical Ventilation (PMV) and they may also present other additional characteristics. The incidence of PMV in the ICU is below 11%, which represents a minority; however, these patients are responsible for a disproportionate amount of resource use, requiring frequent care and with unfavorable outcomes. Objective. To analyze the outcome of patients depending on Prolonged Mechanical Ventilation after discharge from the ICU. Method. This is a retrospective, documentary, descriptive and exploratory cross-sectional study. The study was conducted at the Waldemar Alcântara General Hospital (Hospital Geral Waldemar Alcântara ¿ HGWA). Patient¿s information were obtained from medical records of the adult ICU and the Special Care Unit (SCU). A total of 142 medical records dating from 2012 to 2014 were analyzed. Data were collected from June to September 2015. Data were entered into a collection instrument and analyzed using the Statistical Package for the Social Sciences (SPSS) version 19.0 for Windows. Inferential analysis was performed with statistical significance set at p<0.05. Results. There was a higher percentage of: individuals over 59 years old (28.9%), men (58.5%) and external demand (82.4%). Regarding diagnosis, admission due to CAP associated with respiratory failure presented a higher percentage of records (54.9%) among the comorbidities recorded: hypertension (54.2%), heart disease (34.5%), diabetes (32.4%) and neurological sequelae (19.7%). Smoking (53.7%) was the most common deleterious habit. The main cause that led to mechanical ventilation was acute respiratory failure (90.1%). 15.5% of these patients had undergone some type of surgery, with laparotomy (40.9%) as the most prevalent, and 25.4% of patients underwent further surgeries and laparotomy (55.6%) was once again the most prevalent. The most prevalent complications in the adult ICU were: sepsis (64.1%), acute renal failure treated by dialysis (53.5%) and Pneumonia Associated with Mechanical Ventilation (35.2%). Only 14.1% of patients undergoing Prolonged Mechanical Ventilation (PMV) achieved success in their withdrawal and the main outcomes in the adult ICU were death (35.2%) and discharge (64.1%). In the SCU, nearly a third of patients (30.2%) presented new sepsis, only 39.4% were successful in the withdrawal of mechanical ventilation, 29.3% were decannulated and the main outcomes were death (61.5%), referral to another hospital (1.1%), discharge for the Homecare Program (16.5%) and home car discharge (20.9%). Considering the statistical inferences of the various characteristics listed from diagnosis to admission, comorbidities and complications in ICU, only: Acute Myocardial Infarction, sensory alterations, liver disease, acute renal failure not requiring dialysis, Pneumonia associated with Mechanical Ventilation and Cardiopulmonary Resuscitation presented statistical associations (p<0.05). Previous surgery (laparotomy) before and after admission to the ICU was significantly associated with the outcome (death or discharge) among the records of the adult ICU. Only Acute renal failure requiring dialysis and Hemodynamic Instability were statistically associated with death outcome in the SCU but not with comorbidities. At the end, the duration of mechanical ventilation was statistically associated (p <0.05) with patient¿s outcome in the SCU. Conclusion. Patients undergoing PMV are part of a group with high mortality and permanence rates. A small percentage of this population could succeed in removing the MV and hospital discharge or follow-up by the Home Care Program. / Introdução. Frente aos avanços da tecnologia, dos recursos humanos especializados, da luta para vida de pacientes criticamente enfermos, a Unidade de Terapia Intensiva (UTI), pode originar uma população denominada de ¿doente crítico crônico¿. Estes possuem como característica principal a dependência de Ventilação Mecânica Prolongada (VMP) e pode apresentar também outras características adicionais. A incidência de VMP na UTI encontra-se abaixo de 11%, fato que representa minoria, porém estes são responsáveis por uma quantidade desproporcional de utilização de recursos, com necessidade de cuidados frequentes e desfechos desfavoráveis. Objetivo. Analisar o desfecho do paciente de Ventilação Mecânica Prolongada após alta da UTI. Método. Estudo transversal retrospectivo, documental, descritivo e exploratório realizado no Hospital Geral Waldemar Alcântara (HGWA). As informações do paciente foram originárias dos prontuários da UTI adulto dando segmento com as da Unidade de Cuidados Especiais (UCE). Foram avaliados 142 prontuários do período de 2012 a 2014, sendo a coleta de dados realizada de junho a setembro de 2015. Os dados foram transcritos para um instrumento de coleta e analisados com auxílio do programa Statistical Package for the Social Sciences (SPSS) versão 19.0 para Windows. Para análise de inferência foram considerados significativos os valores de p<0,05. Resultados. Observou-se um maior quantitativo percentual: faixa etária até 59 anos (28,9%), de homens (58,5%) e de procedência externa (82,4%). Com relação ao diagnóstico, à admissão PAC Associada a Insuficiência Respiratória teve maior número percentual de registros (54,9%) entre as comorbidades registradas: hipertensão (54,2%), cardiopatia (34,5%), diabetes (32,4%) e sequelas neurológicas (19,7%). Dos hábitos deletérios, tabagismo (53,7%) foi predominante. A principal causa que levou a intervenção da ventilação mecânica foi IRpA (90,1%). 15,5% destes pacientes já haviam sido submetidos a algum tipo de cirurgia prévia, a laparotomia (40,9%) foi a mais prevalente, 25,4% dos pacientes passaram por novas cirurgias e novamente a laparotomia (55,6%) foi predominante. Dentre as complicações na UTI adulto, prevaleceram: SEPSE (64,1%), Insuficiência Renal Aguda Dialítica (53,5%) e Pneumonia Associada à Ventilação Mecânica (35,2%), apenas 14,1% dos pacientes que estavam submetidos à Ventilação Mecânica Prolongada (VMP) conseguiram obter êxito na sua retirada e na UTI adulto tiveram como desfecho o óbito (35,2%) e alta (64,1%). Na UCE, quase um terço (30,2%) apresentou nova SEPSE, apenas 39,4% tiveram sucesso na retirada da ventilação mecânica neste setor, 29,3% sofreram decanulação e tiveram como desfecho o óbito (61,5%), transferência para outro hospital (1,1%), alta para o Programa de Atendimento Domiciliar (16,5%) e alta domiciliar (20,9%). Nas inferências estatísticas, das diversas características que foram listadas do diagnóstico à admissão, comorbidades e complicações na UTI, somente: Infarto Agudo do Miocárdio, Rebaixamento sensório, Hepatopatia, Insuficiência Renal Aguda não dialítica, Pneumonia Associada à Ventilação Mecânica e Parada Cardiorrespiratória tiveram associações estatísticas (p<0,05), cirurgia prévia (laparotomia) antes e após a internação na UTI, obteve-se significância no desfecho (óbito ou alta) desses prontuários da UTI adulto. Apenas Insuficiência Renal Aguda dialítica e Instabilidade Hemodinâmica tiveram significância estatística com o desfecho referente a óbito na UCE e não houve com as comorbidades e no final o tempo de ventilação mecânica teve relação com significância estatística (p<0,05) com o desfecho do paciente na UCE. Conclusão.Os pacientes em VMP integram um grupo com mortalidade e permanência elevada. Um pequeno percentual dessa população conseguiu obter êxito na retirada da VM, bem como alta domiciliar ou acompanhada pelo Programa de atendimento Domiciliar.
28

Preditores de desmame na extubação

Savi, Augusto January 2012 (has links)
A ventilação mecânica (VM) oferece suporte essencial para vida de pacientes intubados, enquanto o sistema respiratório se recupera da insuficiência respiratória aguda. Entretanto, a VM invasiva está associada a risco aumentado de mortalidade e morbidade. Portanto, desmamar de forma segura o paciente do respirador o mais rápido possível é imperativo. Nos últimos anos, muitos estudos avaliaram uma série de pontos fundamentais para o desenvolvimento desta área, dentre eles a avaliação de preditores de desmame. Os preditores de desmame funcionam como um teste de triagem para identificar quais pacientes podem realizar um teste de ventilação espontânea mais precocemente. Todavia, a avaliação de testes diagnósticos é repleta de dificuldades. Na área do desmame, as questões mais relevantes estão relacionadas à probabilidade pré-teste (que depende de qual momento realizamos a avaliação de um preditor), o viés do teste de referência (que surge quando um teste sob avaliação – preditor de desmame – sofre influência quando o paciente passa pelos testes subsequentes) e pelo viés de espectro, que está diretamente relacionado à população em estudo, isto é, se ela é formada por pacientes menos doentes por exemplo. Todas estas informações devem ser levadas em consideração quando avaliamos um preditor de desmame, e talvez por este motivo esta área apresente resultados tão conflitantes. A falha no desmame é resultado de um desbalanço entre a carga imposta ao sistema respiratório e a capacidade deste sistema. A avaliação de qual paciente tem capacidade de tolerar a retirada do suporte ventilatório é uma área muito complexa e depende de vários fatores, dentre eles o teste de prontidão e a avaliação de índices preditivos. A utilização destes índices é um tema de grande polêmica, com muitos estudos apresentado resultados contraditórios. Diante deste cenário, desenvolvemos uma linha de pesquisa com a finalidade de avaliar o poder de alguns preditores de desmame no momento da extubação. Foram realizados três estudos: o primeiro avaliou a o valor preditivo da saturação venosa central (ScvO2) para detectar a falha da extubação; o segundo avaliou os índices preditivos mais frequentemente utilizados no desmame durante o processo de extubação e o terceiro avaliou o benefício de um protocolo de desmame no sucesso da extubação. A queda da ScvO2 em 4,5% durante o teste de ventilação espontânea obteve uma sensibilidade de 88% e uma especificidade de 95% em predizer a falha de extubação. Em contrapartida, os preditores mais frequentemente utilizados para o desmame como o índice de respiração superficial (IRS), a pressão inspiratória máxima (PImax) e o índice integrativo da Complacência Dinâmica, Frequência Respiratória, Índice de Oxigenação e Pressão Inspiratória Máxima (CROP), não foram preditores de desfecho para a extubação na população geral da UTI. Por fim, a utilização de um protocolo de desmame aumentou a probabilidade de sucesso de extubação em 86.7% no grupo protocolo vs. 69.6% no grupo controle. Podemos concluir que a ScvO2 foi um preditor precoce e independente de falha de extubação; preditores frequentemente utilizados para desmame não parecem acrescentar informações relevantes para a tomada de decisão no processo de extubação e a utilização de um protocolo específico diminuiu a possibilidade de falha de extubação. / Mechanical ventilation (MV) provides essential support for the life of intubated patients, while the respiratory system recovers from acute respiratory failure. However, the invasive MV is associated with increased risk of mortality and morbidity. Therefore, safely weaning the patient from the ventilator as soon as possible is imperative. In recent years, many studies have examined a number of key points for the development of this area, including the assessment of weaning predictors. Weaning predictors serve as a screening test to identify which patients can perform a spontaneous breathing trial as soon as possible. However, the evaluation of diagnostic tests is fraught with difficulties. As part of weaning process, we are faced with the pretest probability (with depends on what time we perform the evaluation of a predictor) the test-referral bias (with arises when a test under evaluation – weaning predictor test – influences which patients undergo either of the two subsequent tests, and spectrum bias, which is directly related to the study population, that is, if it is formed of less severely ill patients. Weaning failure often results from an imbalance between load imposed on respiratory system and the capacity of this system. The evaluation of any patient´s ability to tolerate withdrawal of ventilatory support is a very complex area and depends on several factors, including the readiness test and evaluation of predictors indexes. The use of these indexes is an issue of great controversy, with many studies has shown contradictory results. In this scenario, we developed a research with the aim to assessing the power of some weaning predictors at the extubation time. We performed three studies: the first study evaluate the predictive power of central venous saturation (ScvO2) to detect extubation failure; the second study assessed the most frequently predictive indexes used on weaning process during extubation period; and the third study assessed the benefit of a weaning protocol for extubation outcome. The reduction of ScvO2 by 4.5% during spontaneous breathing trial was an independent predictor of reintubation, with a sensitivity of 88%, and a specificity of 95%. In contrast, the most commonly often used weaning predictors, such as rapid shallow breathing index (RSBI), maximal inspiratory pressure (MIP) and the integrative index of compliance, respiratory rate, oxygenation and maximal inspiratory pressure (CROP) were poor not good predictors of extubation outcome in the overall ICU population. Finally, the use of a weaning protocol increased the likelihood of extubation success at 86.7% in the protocol group vs. 69.6% in the control group. We can conclude that ScvO2 was an early and independent predictor of extubation failure; predictors often used during weaning does not seem to add relevant information for decision making in the process of extubation; and the use of specific weaning protocol decrease the possibility of extubation failure.
29

Uma nova metodologia baseada na avaliação heurística e simulação realista para o desenvolvimento de interfaces de ventiladores mecânicos centrado no usuário / A new method based on heuristic evaluation and realistic simulation for the development of mechanical ventilators centered on the user interface

Maia, Nathalia Parente de Sousa January 2014 (has links)
MAIA, N. P. S. Uma nova metodologia baseada na avaliação heurística e simulação realista para o desenvolvimento de interfaces de ventiladores mecânicos centrado no usuário. 90 f. Dissertação (Mestrado em Ciências Médicas) – Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Eliene Nascimento (elienegvn@hotmail.com) on 2015-03-17T12:58:18Z No. of bitstreams: 1 2014_dis_npsmaia.pdf: 2290378 bytes, checksum: d93786e2cf5754025c338f1cc9737fec (MD5) / Approved for entry into archive by denise santos(denise.santos@ufc.br) on 2015-03-17T13:31:45Z (GMT) No. of bitstreams: 1 2014_dis_npsmaia.pdf: 2290378 bytes, checksum: d93786e2cf5754025c338f1cc9737fec (MD5) / Made available in DSpace on 2015-03-17T13:31:45Z (GMT). No. of bitstreams: 1 2014_dis_npsmaia.pdf: 2290378 bytes, checksum: d93786e2cf5754025c338f1cc9737fec (MD5) Previous issue date: 2014 / Introduction: New human-machine interfaces have been developed to incorporate the new modes and ventilatory parameters. Multiple monitoring data and alarms are presented in graphical interfaces, which many consider still far from ideal for the primary users, healthcare professionals. Hypothesis: Noncompliance with the heuristic human machine interaction can compromise the usability of lung mechanical ventilators by users (doctors, nurses, physiotherapists) Objectives: To develop a new methodology for evaluating and implementing improvements on a ventilator interface pulmonary mechanical intensive care unit (ICU) second heuristic principles. Methods: An experimental study, using two methodologies: one centered on heuristic evaluation by an expert, and the second one focused on a comparative assessment by non-experts. Was held during the period from January 2013 to March 2014, the Laboratory of Respiratory (RespLab). The research was divided into three steps: 1st) evaluating the usability of six habilities (connect, adjust or alter ventilation modes and their parameters; adjust and react appropriately to different types of alarms, monitor respiratory mechanical parameters, and set the trigger mode non-invasive) ventilation interface for experts users; 2nd) Implementation of suggestions for improvements to the interface by a team of specialist engineers in mechanical ventilation (MV); 3rd) Comparison between interfaces (old and new), for users not experts, assessing six tasks (call, adjust the patient, adjust the volume control ventilation (VCV), measurement of mechanical, adjust the pressure control ventilation (PCV), pressure suport ventilation adjustment (PSV). The analysis of the 1st step was descriptive. The outcomes of the 3rd step were: execution´s runtime and successes of tasks and usability score by analogic visual scale (AVS). Results: Step 1: Participants 8 professional experts. 93 problems were listed. The most violated principles: 5 (error prevention), 1 (Visibility of System Status) and 7 (Flexibility and efficiency of use). 2nd step: passed on and discussed all reports completed by experts users. Changes in the interface were performed following the suggestions and principles heuristics. 3rd step: VCV adjustment, mechanical ventilation and PSV adjustment required longer time to execute; p = 0.02 for the runtime of the task of connecting when first used, to the old interface; p = 0.02 for correct setting of PSV when first held in the new interface; p = 0.08 for the usability score, favoring the new interface. Conclusion: It was possible to develop a new methodology for evaluating and implementing improvements on a mechanical ventilator in ICU interface according to the heuristics. / Introdução: Novas interfaces homem-máquina foram desenvolvidas para incorporar os novos modos ventilatórios e parâmetros de ventilação. Múltiplos dados de monitorização e alarmes são apresentados nas interfaces gráficas, que muitos consideram ainda longe da ideal para os usuários primários, os profissionais de saúde. Hipótese: O não atendimento aos princípios heurísticos da interface homem-máquina pode comprometer a usabilidade de ventiladores pulmonares por seus usuários (médicos, enfermeiros, fisioterapeutas) Objetivos: Desenvolver uma nova metodologia de avaliação e implementação de melhorias na interface de um ventilador pulmonar mecânico de uma unidade de terapia intensiva (UTI) segundo princípios heurísticos. Métodos: Estudo experimental, utilizando-se duas metodologias: uma centrada na avaliação heurística por expert, e a segunda, centrada em uma avaliação comparativa por não experts. Realizou-se durante o período de janeiro de 2013 a março de 2014, no Laboratório da Respiração (RespLab). A pesquisa dividiu-se em 3 fases: 1ª) avaliação da usabilidade de seis habilidades (ligar; ajustar ou alterar modos ventilatórios e seus parâmetros; ajustar e reagir apropriadamente os diferentes tipos de alarmes ; monitorar parâmetros de mecânica respiratória, acionar e ajustar o modo de ventilação não invasiva) da interface por usuários experts; 2ª) Implementação das sugestões de melhorias na interface por uma equipe de engenheiros especialistas em ventilação mecânica; 3ª) Comparação entre interfaces (antiga e nova), por usuários não experts, avaliando 6 tarefas (ligar, ajuste do paciente, ajuste do modo de ventilação a volume controlado (VCV), mensuração da mecânica, ajuste do modo de ventilação a pressão controlada (PCV), ajuste do modo de ventilação a pressão de suporte (PSV). A análise da 1ª fase foi descritiva. Os desfechos da 3ª fase foram: tempo de execução e acertos das tarefas, e escore de usabilidade através da Escala Visual Analógica (E.V.A.). Resultados: 1ª fase: Participaram 8 profissionais experts. Ao total, foram listados 93 problemas. Os princípios mais infringidos foram: 5 (Prevenção de erro), 1 (Visibilidade do Status do Sistema) e 7 (Flexibilidade e eficiência de utilização). 2ª fase: repassados e discutidos todos os relatórios preenchidos pelos usuários experts. Modificações na interface foram realizadas seguindo as sugestões e princípios heurísticos. 3ª fase: ajuste do VCV, mecânica ventilatória e ajuste do PSV necessitaram de maior tempo para execução; p=0,02 para o tempo de execução da tarefa de ligar, quando usado pela primeira vez, para a interface antiga; p=0,02 para o ajuste correto do PSV quando realizado pela primeira vez na interface nova; p=0,08 para o escore de usabilidade, favorecendo a interface nova. Conclusão: Foi possível desenvolver uma nova metodologia de avaliação e implementação de melhorias na interface de um ventilador pulmonar mecânico de UTI segundo os princípios heurísticos.
30

Papel protetor da laringe e da traquéia proximal na prevenção de lesões epiteliais causadas pela inalação de gases condicionados : estudo experimental em cães /

Dias, Norimar Hernandes. January 2008 (has links)
Orientador: Regina Helena Garcia Martins / Banca: José Reinaldo Cerqueira Braz / Banca: Júlio Defaveri / Banca: João Ferreira de Mello Júnior / Banca: Wilma Terezinha Anselmo-Lima / Resumo: Durante a inspiração, grande parte da umidade e do calor é incorporada ao ar durante sua passagem pelas fossas nasais e rinofaringe. Entretanto, quando as fossas nasais estão impedidas de participar do condicionamento dos gases como no paciente respirador bucal, traqueotomizado, sob intubação traqueal ou laringectomizado, os demais segmentos das vias aéreas passam a atuar mais ativamente na tarefa do condicionamento. Vários autores têm constatado lesões na mucosa respiratória frente à inalação de gases secos e frios. Estudos experimentais morfológicos do epitélio respiratório demonstraram importantes alterações, como áreas de completa desorganização e agrupamentos dos cílios, além de zonas de devastação. Em pesquisa experimental prévia, foi quantificada e constatada a participação ativa do segmento laringotraqueal no condicionamento dos gases inalados, quando se utiliza a máscara laríngea na manutenção da permeabilidade da via aérea. Entretanto, nesse estudo, a necessidade de monitoramento constante da temperatura e da umidade do ar inalado e traqueal exigia manipulação freqüente da traquéia cervical, o que inviabilizou a realização de estudo morfológico complementar do epitélio respiratório. Objetivo: analisar, no cão, por meio de estudo morfológico, o papel protetor da laringe e da traquéia proximal na prevenção de lesões epiteliais, causadas pela inalação de gases pouco condicionados. Material e Métodos: A pesquisa recebeu aprovação do Comitê de Ética em Experimentação Animal sob o protocolo de no 442/04. Doze cães adultos foram submetidos à anestesia venosa com pentobarbital sódico e ventilação mecânica, com alto fluxo de gases frescos, em sistema sem reabsorção de CO2, durante 3 horas. Os animais foram distribuídos em dois grupos experimentais, dependendo do dispositivo utilizado para a manutenção da via aérea: GrupoTT - tubo traqueal e Grupo ML - máscara laríngea. / Abstract: During inhalation, moisture and heat is incorporated to the air in its passage through the nose and rhinopharynx. However, when the nose doesn't participate in gas conditioning, such as in mouth-breathing, tracheotomized, intubated or laryngectomized patients, other segments of the airways participate more actively in the conditioning task. Lesions in the respiratory mucosa have been detected due to the inhalation of dry and cold air. Morphologic studies of the respiratory epithelium have shown important alterations, such disorganization, ciliary clusters and devastation. In a previous experimental study, we were verified and quantified the active participation of the laryngotracheal segment in the conditioning of inhaled gases, using laryngeal mask airway for maintaining airway permeability. However the need of constant controlling of the temperature and moisture of the gases required frequent handling of the cervical trachea, and did not permit a complementary morphologic study of the respiratory epithelium. Objective: to study the protective function of the larynx and proximal trachea in dogs, preventing epithelial lesions caused by the inhalation of poor conditioned gases. Material and Methods: the study was approved by the ethics committee for animal experimentation under registration number 442/04. Twelve adult dogs were submitted to venous anesthesia with sodium pentobarbital and mechanical ventilation in a system without CO2 resorption for three hours. The animals were distributed into two experimental groups, depending on the tube used for airway maintenance: Group TT - tracheal tube and Group ML - laryngeal mask airway. Hemodynamic parameters (blood pressure, heart rate), ventilatory parameters (respiratory rate, current volume, peripheral oxyhemoglobin saturation, PETCO2, inspiratory pressure), tympanic temperature, temperature, relative and absolute moisture of the ambient and inhaled gases were analyzed. / Doutor

Page generated in 0.0286 seconds