• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1738
  • 22
  • 11
  • 10
  • 9
  • 8
  • 8
  • 5
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 1794
  • 1380
  • 1185
  • 979
  • 497
  • 473
  • 455
  • 438
  • 293
  • 177
  • 166
  • 151
  • 125
  • 104
  • 98
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
651

Theranostic nanomaterials applied to the cancer diagnostic and therapy and nanotoxicity studies / Nanomateriais Teranósticos Aplicados à Problemática do Câncer e Estudos de Nanotoxicidade.

Valeria Spolon Marangoni 29 June 2016 (has links)
Multifunctional plasmonic nanoparticles have shown extraordinary potential for near infrared photothermal and triggered-therapeutic release treatments of solid tumors. However, the accumulation rate of the nanoparticles in the target tissue, which depends on their capacity to escape the immune system, and the ability to efficiently and accurately track these particles in vivo are still limited. To address these challenges, we have created two different systems. The first one is a multifunctional nanocarrier in which PEG-coated gold nanorods were grouped into natural cell membrane vesicles from lung cancer cell membranes (A549) and loaded with β-lap (CM-β-lap-PEG-AuNRs). Our goal was to develop specific multifunctional systems for cancer treatment by using the antigens and the unique properties of the cancer cell membrane combined with photothermal properties of AuNRs and anticancer activity of β-lap. The results confirmed the assembly of PEG-AuNRs inside the vesicles and the irradiation with NIR laser led to disruption of the vesicles and release of the PEG-AuNRs and β-Lap. In vitro studies revealed an enhanced and synergic cytotoxicity against A549 cancer cells, which can be attributed to the specific cytotoxicity of β-Lap combined with heat generated by laser irradiation of the AuNRs. No cytotoxicity was observed in absence of laser irradiation. In the second system, MRI-active Au nanomatryoshkas were developed. These are Au core-silica layer-Au shell nanoparticles, where Gd(III) ions are encapsulated within the silica layer between the inner core and outer Au layer of the nanoparticle (Gd-NM). This theranostic nanoparticle retains its strong near infrared optical absorption properties, essential for in vivo photothermal cancer therapy, while simultaneously providing increased T1 contrast in MR imaging by concentrating Gd(III) within the nanoparticle. Measurements of Gd-NM revealed a substantially enhanced T1 relaxivity (r1 ~ 17 mM-1 s-1) even at 4.7 T, surpassing conventional Gd(III)-DOTA chelating agents (r1 ~ 4 mM-1 s-1) currently in clinical use. The observed relaxivities are consistent with Solomon-Bloembergen-Morgan (SBM) theory, describing the longer-range interactions between the Gd(III) and protons outside the nanoparticle. These novel multifunctional systems open the door for the development of more efficient nanoplatforms for diagnosis and treatment of cancer. / Nanopartículas plasmônicas multifuncionais têm revelado elevado potencial para fototermia na região (NIR) do infravermelho e liberação controlada de fármacos para o tratamento de tumores sólidos. No entanto, a taxa de acumulação das nanoparticulas no tecido alvo, que depende da capacidade delas de escapar do sistema imunológico, e a habilidade de rastrear de maneira efetiva essas partículas in vivo ainda são limitadas. Para superar essas barreiras, dois sistemas diferentes foram desenvolvidos. O primeiro corresponde a um nanocarreador multifunctional, onde nanobastões de ouro funcionalizados com PEG foram agrupados dentro de vesículas de membranas de células naturais originarias de células cancerígenas de pulmão (A549) conjugadas com β-Lap (CM-β-lap-PEG-AuNRs). Nosso principal objetivo foi desenvolver um sistema multifuncional especifico para tratamento de câncer utilizando os antígenos e propriedades únicas da membrana das células cancerígenas combinados com as propriedades fototérmicas dos AuNRs e a atividade anticancerígena da β-Lap. Os resultados confirmaram o agrupamento dos PEG-AuNRs dentro das CM e irradiação com o laser no NIR levou ao rompimento das vesículas e liberação dos AuNRs e β-Lap. Estudos in vitro revelaram uma elevada e sinérgica citotoxicidade contra células A549, que pode ser atribuída a combinação da especifica toxicidade da β-Lap com o calor gerado pelos AuNRs por meio da irradiação com laser. Nenhuma citotoxicidade significativa foi observada na ausência de irradiação com laser. No segundo sistema, nanomatryoshkas de Au ativas em MRI foram desenvolvidas. Elas consistem em um núcleo de Au, uma camada intersticial de sílica, onde os íons de Gd(III) são encapsulados, e uma camada externa de Au (Gd-NM). Esta nanopartícula teranóstica mantém as propriedades de elevada absorção óptica no NIR, enquanto simultaneamente fornece um elevado contraste T1 em imagem por ressonância magnética por meio da concentração dos íons de Gd(III) dentro da nanoparticula. Medidas de Gd-NM revelaram uma relaxividade elevada (r1 ~ 17 mM-1 s-1 ) a 4,7 T, superando os convencionais agentes quelantes de Gd(III)-DOTA (r1 ~ 4 mM-1 s-1) utilizados clinicamente. As relaxividades observadas são consistentes com a teoria Solomon-Bloembergen-Morgan (SBM), descrevendo as interações de longo alcance entre Gd(III) e prótons de H fora da partícula. Os novos sistemas multifuncionais desenvolvidos abrem oportunidades para o desenvolvimento de nanoplataformas mais eficientes para o diagnóstico e tratamento de câncer.
652

Quantificação da perfusão sanguínea cerebral utilizando arterial spin labeling: aplicações em medidas de territórios vasculares e em imagens funcionais / Cerebral perfusion quantification using arterial spin labeling: applications in vascular territories measurement and functional imaging

Fernando Fernandes Paiva 06 June 2008 (has links)
Arterial spin labeling é uma técnica completamente não invasiva que permite o monitoramento quantitativo da perfusão cerebral e, juntamente com outras técnicas de ressonância magnética, tem se estabelecido como uma excelente ferramenta para estudos relacionados à hemodinâmica e problemas vasculares cerebrais. Dentre as possíveis implementações da técnica, a abordagem contínua, combinada a uma bobina de marcação dedicada, apresenta algumas vantagens com relação à relação sinal-ruído e à deposição de potência de RF. No presente trabalho, estas vantagens foram exploradas na implementação de uma metodologia que permite a obtenção de mapas quantitativos de fluxo sanguíneo cerebral, bem como dos territórios vasculares das principais artérias suprindo o cérebro. Os resultados obtidos em humanos e animais revelam a robustez e aplicabilidade da técnica em estudos da hemodinâmica cerebral. Aplicações em hipertensão comprovam que a técnica é capaz de fornecer informações que podem auxiliar na compreensão de diferentes patologias. A implementação da variante dinâmica da técnica ASL demonstra a versatilidade da metodologia fornecendo ferramentas para uma maior compreensão das características espaciais e temporais da hemodinâmica cerebral. Os resultados demonstram isto tanto em condições de fluxo sanguíneo basal como em hiperemia causada por estímulos funcionais. / Arterial spin labeling techniques allow to obtain quantitative maps of perfusion non-invasively. Along with other MRI techniques, it has proven useful for diagnosis of a variety of cerebrovascular diseases. Amongst the available basic implementations, the continuous approach employing a dedicated labeling RF coil has the advantages of presenting high signal-to-noise ratio and lower RF power deposition. In the present work, these advantages were explored in order to implement a methodology to obtain quantitative maps of cerebral blood flow and the vascular territories of the major cerebral feeding arteries. Human and animal results reveal the robustness and applicability of the technique in cerebral hemodynamic studies. Applications in hypertension show that the technique can provide complimentary information to improve the understanding of neurovascular diseases. The dynamic ASL technique shows the method versatility for studying the spatial and temporal characteristics of cerebral hemodynamics. The results unravel that both under basal and functional hyperemia conditions.
653

Espectrômetro de RMN de campo remoto / NMR spectrometer with remote magnetic field

Eduardo Shiguemi Kakuda 02 October 1998 (has links)
Nos espectrômetros de RMN convencionais as amostras são colocadas dentro do gap do ímã, onde encontra-se a região de campo magnético mais intenso e homogêneo. Nessa configuração o tamanho do ímã aumenta de acordo com o tamanho da amostra, dificultando a aplicação da RMN para amostras muito volumosas. Uma configuração em que o ímã não precisa aumentar com o volume da amostra tem sido a geração de campo magnético remoto, onde a região ótima de análise, de campo mais intenso e homogêneo, fica fora do gap do ímã. Neste trabalho avaliou-se os métodos de geração de campo magnético remoto por ímã permanente na forma de ferradura e de campo oposto, para aplicação em RMN. Os ímãs na forma de ferradura foram construídos com cilindros de AlNiCo V, com 100mm de comprimento e130mm de diâmetro, e NdFeB. O ímã de campo oposto foi construído com cilindros de NdFeB com 25mm de espessura e 100mm de diâmetro. Utilizando os ímãs na forma de ferradura, não foi possível observar sinal de RMN pois ha um enorme gradiente de campo que restringe a área útil de análise. Com o ímã de campos opostos foi possível observar o sinal de RMN externamente ao gap do ímã com um campo da ordem de 1,75KGauss. Mesmo com esse ímã a homogeneidade não e muito alta, mas é suficiente para avaliações quantitativas de teores de óleo e umidade em sementes, bem como a cinética de absorção de água pelas sementes. Analisou-se também o comportamento dos modelos angulados para estes dois tipos, mas não se obteve resultados satisfatórios / In a conventional NMR spectrometer the samples are placed inside of the magnet where is situated the most intense and homogeneous area. In this configuration the size of the magnet increases with the volume of the sample, hindering the applications of NMR to very large samples. A way to eliminate this problem is to use magnets that generate a remote magnetic field, where the intense and homogeneous area is outside it. In this work we evaluated two types of magnets for remote NMR. One is a U shaped magnet and the other is a magnet with opposite field. The U shaped magnets were built with two AlNICo V cylinders, seizing 100 mm in length and 130 mm in diameter or two NdFeB cylinders, seizing 25 mm in length and 100 mm in diameter. The magnet with opposite field was build with two cylinders NdFeB. With the U shaped magnet it was not possible to observe the NMR signal due to an enormous magnetic field gradient that restricts the useful area of analysis. Using the magnet with opposite field, it was possible to observe NMR signal outside the magnet with a field of the order of 1,75 KGauss. With this magnet the homogeneity was not very high but it was enough to perform qualitative and quantitative evaluation of oil and humidity in seeds and the kinetics of water absorption by them. The performance of the angled models was analyzed for the two types, but the results obtained were not satisfactory
654

Estudo da morfologia de rochas sintéticas através de imagens por Ressonância Magnética / Study of the morphology of synthetic rocks through Magnetic Resonance Imaging

Camila Cardoso 07 February 2018 (has links)
Uma área de aplicação da Ressonância Magnética (RM) que tem crescido recentemente é a de meios porosos, principalmente devido ao interesse da indústria petrolífera. Entretanto, até o presente momento, muito do que foi feito se baseia em medidas de relaxometria, o que impossibilita qualquer tipo de avaliação espacial desses meios. O presente trabalho teve como objetivo principal desenvolver, implementar e avaliar a aplicabilidade de métodos de imagens por RM para o estudo da morfologia de meios porosos. Esses sistemas apresentam tempos de relaxação bastante curtos, além de diferenças de susceptibilidade entre as paredes da rocha e os poros, o que compromete a qualidade dos dados de RM. Por essa razão, no presente trabalho nos concentramos em avaliar as imagens obtidas por RM, no que se refere à morfologia, usando imagens obtidas por microtomografia como referência. Os resultados revelaram que, apesar da variação na susceptibilidade do meio e dos baixos tempos de relaxação, o comprometimento na avaliação final esteve abaixo da resolução espacial da técnica e, portanto, não se configura como um limitante. Isso sugere que a técnica de imagens por RM pode contribuir para o estudo de meios porosos. Embora a microtomografia já ofereça bons resultados para o estudo de morfologia, imagens por RM devem viabilizar a investigação não invasiva de problemas nos quais a dinâmica de fluidos é relevante, o que ainda representa um desafio na área de estudos de meios porosos. / A recently growing application area of Magnetic Resonance (MR) is that of porous media, mainly due to the interest from the petrol industry. However, until the present moment, however, most of what has been done is based on relaxometry measures, which forbids any kind of special evaluation of these media. The objective of this work was to develop, implement and evaluate the applicability of MR imaging methods for the study of the morphology of porous media. These systems have very short relaxation times and considerable susceptibility differences between the rock walls and the pores, both of which compromise the quality of the data obtained via MR. For this reason, in this current work we focused on evaluating the MR images, with respect to morphology, using images obtained via microtomography as reference. Our results showed that, despite the susceptibility variations on the media and the short relaxation times, the errors in the final evaluation were below the spatial resolution threshold and, therefore, are not considered as a limiting factor. This suggests that MR imaging techniques can indeed contribute to the study of porous media. Although microtomography already offers good results on morphology studies, MR imaging can turn feasible the non-invasive investigation of problems on which the fluid dynamics is relevant, an issue which still represents a challenge in the study of porous media.
655

Avaliação de dose administrada no tratamento de neoplasia ginecológica por ressonância de spin eletrônico com L-alanina / Dose evaluation administered in the treatment of gynecological câncer by eléctron spin resonance with L-alanine

Amanda Burg Rech 29 June 2012 (has links)
Neoplasias ginecológicas são os tumores de maior incidência no público feminino. Como alternativa para o tratamento destes tumores existe a radioterapia, em que a sua eficácia depende prioritariamente da correta administração da dose prescrita ao tumor, com acurácia de ±5%, conforme estabelecido pela American Association of Physicists in Medicine (AAPM). Para verificar a administração de doses existem diversas técnicas dosimétricas, entre elas a ressonância de spin eletrônico (RSE) com L-alanina, material tecido-equivalente, que relaciona dose com a quantidade de radicais livres formados pela radiação. Portanto, o objetivo deste estudo é a verificação da dose administrada na região tumoral de pacientes diagnosticadas com câncer ginecológico submetidas à teleterapia, utilizando L-alanina e a RSE. Para comparação entre as modalidades de radioterapia, foi realizada braquiterapia ginecológica com objeto simulador, verificando a dose no reto durante o tratamento, que deve ser inferior a 65% da dose prescrita ao tumor, conforme a International Commission on Radiation Units (ICRU). Para a análise de teleterapia foi construído um aparato, para a inserção vaginal do material radio-sensível, que foi utilizado durante 5 das 25 sessões de tratamento. As doses foram determinadas com o sistema de planejamento do tratamento mediante as imagens da tomografia computadorizada, em conjunto com softwares de planejamento, e a existência de marcadores radiopacos no aparato permitiu a confirmação das doses, conforme referência óssea através de imagens de portal feitas no momento anterior ao tratamento. Após a irradiação foi feita a leitura das amostras com o espectrômetro de RSE, em que a amplitude pico a pico da linha principal do sinal, normalizado pela massa, determinou a dose entregue nas regiões de interesse. Previamente ao estudo in vivo foi efetuada a teleterapia com objeto simulador, nas mesmas condições de tratamentos in vivo, apresentando desvio médio em relação ao planejamento de (0,2 ± 3,5)%, viabilizando o estudo com pacientes. Para a primeira paciente o desvio médio obtido foi de (0,5 ± 3,7)% e para a segunda de (-0,7 ± 2,8)%. Na simulação da braquiterapia o desvio médio observado foi de (-1,3 ± 9,2)%. Por causa do pequeno número amostral de pacientes, esta pesquisa é classificada como um estudo de viabilidade, em que a utilização de L-alanina com a RSE se mostrou eficiente para o objetivo proposto, fazendo com que os resultados da teleterapia estivessem de acordo com o estipulado pela AAPM e na braquiterapia a dose administrada no reto obedecesse ao relatório 38 da ICRU. / Gynecological malignancies are the most incident female tumors. As an alternative treatment for these tumors exist the radiotherapy, which their effectiveness mainly depends on the right administration of the prescribed dose to the tumor, with an accuracy of ±5%, as established by the American Association of Physicists in Medicine (AAPM). There are a lot of dosimetric techniques for dose verification, including electron spin resonance (ESR) with L-alanine, a tissue-equivalent material, which relates dose with the amount of free radicals formed by radiation. Therefore, the aim of this study is to verify the dose administered in the tumor of patients diagnosed with gynecological cancer subjected to external beam radiation therapy using L-alanine and ESR. For comparison between the radiotherapy modalities was performed gynecological brachytherapy in phantom, verifying the dose to the rectum during treatment, which must be less than 65% of the prescribed dose to the tumor, according to the International Commission on Radiation Units (ICRU). For teletherapy analysis was constructed an apparatus for vaginal insertion of the radio-sensitive material, which was used in 5 of the 25 treatment fractions. The doses were determined with the treatment planning system with the computed tomography images, together with the planning software, and the existence of radiopaque markers in the apparatus allowed the dose confirmation, according to the bone reference through portal images made before treatment. After the irradiation the samples was read with the ESR spectrometer, wherein the peak to peak amplitude of the signal main line, normalized by weight, determined the dose delivered into the regions of interest. Prior to the in vivo study was performed the teletherapy with phantom, under the same conditions of in vivo treatments, presenting mean deviation to the planning dose of (0.2 ± 3.5)%, enabling the study with patients. For the first patient, the mean deviation obtained was of (0.5 ± 3.7)% and for the second one of (-0.7 ± 2.8)%. In the brachytherapy simulation the mean deviation observed was of (-1.3 ± 9.2)%. Due to the small sample of patients, this research is classified as a feasibility study, which the use of L-alanine with the ESR was efficient for the objective proposed, making the teletherapy results consistent with the stipulated by the AAPM, and in the brachytherapy the dose to the rectum obey the ICRU report 38.
656

Projeto de transdutores e otimização do sistema de recepção do tomógrafo de RMN de campo magnético ultrabaixo / Mri coil design and receiver system for ultra low field magnetic resonance imaging

Edson Luiz Géa Vidoto 24 March 1995 (has links)
O objetivo deste trabalho foi melhorar a relação sinal-ruído de um sistema de imagens por ressonância magnética nuclear (TORM 005), através do desenvolvimento de bobinas de recepção mais eficientes, de circuitos de sintonia balanceados, circuitos de desacoplamento de potência para as bobinas receptoras e da melhoria do ambiente eletromagnético no qual os transdutores trabalham. Para isso, houve necessidade de se modificar a blindagem eletromagnética interna ao TORM 005 e incorporar filtros nas linhas de sinal mais críticas para o sistema. Novas bobinas para imagem foram desenvolvidas, melhorando a relação sinal-ruído e permitindo a execução de exames clínicos de diversas anatomias com qualidade superior. Sistemas de sintonia balanceados para as bobinas foram estudados e implementados, garantindo uma redução nas perdas destas bobinas devido a presença de um paciente em seu interior e permitindo uma maior reprodutibilidade da sintonia delas quando um paciente é substituído por outro. Circuitos para proteção da entrada do receptor e para desacoplamento da bobina receptora durante os pulsos de RF na transmissão foram desenvolvidos, construídos e incorporados ao TORM 005. O conjunto destas implementações garantiram ao TORM 005 uma melhora na relação sinal-ruído, na confiabilidade de operação e na reprodutibilidade dos resultados e conseqüentemente uma melhor qualidade da imagem,, o que tem permitido o uso constante do aparelho para aplicações clínicas e no desenvolvimento de novos trabalhos relacionados com imagem por RMN em ultra-baixo campo magnético. / The aim of the present work was to optimize the signal to noise ratio in our NMR imaging system (TORM 005) by improving transducers\' reception quality through better designed coils, balanced tuning circuit for this coils and power decoupling circuits and by reducing interference from the electromagnetic environment. For this purpose, we had to modify the internal electromagnetic shielding and incorporate line filters in the more critica1 signal paths. Also, new types of coils were developed, improving the signal to noise ratio, and allowing us to make clinical exams with superior quality for severa1 anatomies. Balanced circuits for tuning and matching of the coil were studied and built, allowing a reduction of the coil losses because patient\'s load. This produced a more reliable coil tuning after positioning each new patient. Circuits to avoid the receiver input overload and decoupling circuits for the isolation of receiver coils from excitation coil were designed and incorporated to the TORM 005. All these alterations of our imaging system (TORM 005) contributed to a significant improvement in the signal to noise ratio, reliability and reproducibility of the system. This permitted to operate the system routinely for clinical applications, research and development in the area of ultra low magnetic field tomography.
657

Avaliação da perfusão sanguínea cerebral em modelos animais de hipertensão utilizando Arterial Spin Labeling / Cerebral perfusion evaluation in animal models of hypertension using arterial spin labeling

Renata Ferranti Leoni 28 September 2011 (has links)
A hipertensão arterial é uma doença que aflinge mais de um quarto da população adulta mundial e mais da metade da população idosa. Ela é o principal fator de risco para doenças cerebrovasculares e o segundo fator de risco, após idade, para os acidentes vasculares cerebrais (AVC) hemorrágico e isquêmico. É também a principal causa de declínio cognitivo e demência, incluindo a doença de Alzheimer. A hipertensão causa remodelamento vascular e modifica os mecanismos de regulação do fluxo sangüíneo cerebral, incluindo a hiperemia funcional, a autoregulação cerebrovascular e a regulação endotelial. Portanto, pesquisas contínuas sobre os efeitos da hipertensão na função cerebrovascular são cruciais para o desenvolvimento de terapias preventivas que objetivam minimizar os riscos de desenvolvimento de doenças cerebrovasculares. No presente estudo, a perfusão cerebral de um importante modelo experimental de hipertensão, o rato SHR (do inglês spontaneously hypertensive rat), foi avaliada utilizando as técnicas de arterial spin labeling (ASL), que permitem a quantificação não-invasiva da perfusão. Utilizando o método de ASL contínua, o fluxo sangüíneo cerebral foi quantificado para todo o cérebro do rato sob condições de normocapnia e hipercapnia. Resistência cerebrovascular aumentada e reatividade vascular ao CO2 reduzida foram observadas em SHR adultos, confirmando que a hipertensão leva à redução progressiva da capacidade de dilatação da vasculatura cerebral. A técnica de ASL dinâmica permitiu medir o fluxo sangüíneo cerebral funcional evocado por estimulação somatosensorial. Além de apresentarem resposta hemodinâmica positiva à estimulação, os ratos hipertensos também apresentaram resposta hemodinâmica negativa em áreas circundantes àquelas ativadas positivamente. Foi mostrado que esse resultado está relacionado com um efeito puramente hemodinâmico causado pela pressão arterial elevada e pela reserva vascular alterada do SHR. Experimentos farmacológicos mostraram diferenças na modulação do acoplamento neurovascular de SHR quando comparado com rato normotenso. Além disso, SHR submetidos à oclusão temporária da artéria cerebral média apresentaram maior volume da lesão isquêmica e do edema cerebral, redução severa da massa corporal e déficits neurológicos piores do que ratos normotensos. Esses resultados estão relacionados à autoregulação cerebral alterada e ao desenvolvimento prejudicado da circulação colateral em SHR. Em suma, os achados do presente estudo mostraram que a hipertensão resulta em reserva vascular prejudicada, acoplamento neurovascular alterado e piores conseqüências a um AVC isquêmico. / Hypertension is a disease that afflicts more than a quarter of the general population and more than half of the elderly population. It is the most important modifiable risk factor for cerebrovascular diseases and the second most important risk factor, after age, for hemorrhagic and ischemic stroke. It is a leading cause of cognitive decline and dementia, including the Alzheimer\'s disease. Hypertension causes vascular remodeling and modifies the intricate mechanisms of cerebral blood flow (CBF) regulation, including functional hyperemia, cerebrovascular autoregulation, and endothelial regulation. For all of the above, continued research on the effects of hypertension on cerebrovascular function is a crucial step in the design of preventive therapies aimed at minimizing the risk of development of cerebrovascular disease. In the present work, cerebral perfusion of an important experimental model of hypertension, the spontaneously hypertensive rat (SHR), was evaluated using the arterial spin labeling (ASL) techniques, which allow non-invasive quantification of perfusion. Using continuous ASL, CBF was quantified for the whole rat brain under normocapnic and hypercapnic conditions. Increased cerebrovascular resistance and decreased vascular reactivity to CO2 were observed in adult SHR, confirming that hypertension leads to reduced compliance of the cerebral vasculature. The dynamic ASL technique allowed the measurement of functional CBF evoked by somatosensorial stimulation. Hypertensive rats not only showed positive hemodynamic response to stimulation, but also negative hemodynamic response in areas surrounding the positively activated areas. It was shown to be related to a purely hemodynamic effect caused by high blood pressure and impaired vascular reserve of the SHR. Pharmacological experiments showed differences on modulation of the neurovascular coupling in SHR when compared to normotensive rats. Moreover, hypertensive rats subjected to temporary middle cerebral artery occlusion had larger ischemic lesion volume and brain edema, severe decrease in body weight and worse neurological deficits, when compared to normotensive rats. These results are related to the altered cerebral autoregulation and impaired collateral circulation development in SHR. Taken together, the findings of the present work show that hypertension results in impaired vascular reserve, which is related to altered neurovascular coupling and worse stroke outcome.
658

Otimização da segmentação e processamento de imagens do encéfalo com ênfase para lesões da substância branca / Image processing optimization for brain white matter lesion segmentation

Antonio Carlos da Silva Senra Filho 05 September 2017 (has links)
Esclerose Múltipla (MS) é uma doença neurodegenerativa que tem ganhado grande atenção nas últimas décadas, sendo o diagnóstico por imagens de ressonância magnética (MRI) um grande aliado para a avaliação da doença.Porém, um dos principais desafios é garantir uma maior sensibilidade e especificidade para detecção de diferentes lesões no sistema nervoso central (CNS) e assim classificar as diferentes variantes da MS, auxiliando na tomada de decisão para o tratamento farmacológico. Nas últimas décadas, a técnica de imagens ponderadas por difusão (DWI), em especial a técnica de imagem por tensor de difusão (DTI), têm sido evidenciada com grande potencial para o estudo da MS, apresentando uma melhora significativa para a detecção de lesões sutis, ainda em estágios iniciais da MS. Desta forma, as técnicas de processamento de imagens estão em constante aprimoramento para que sejam adaptados às novas modalidades de aquisição de imagens. Neste estudo focamos o desenvolvimento de uma técnica de processamento digital de imagens multimodais a fim de proporcionar uma solução viável para a rotina de diagnóstico por imagem em MS. Um conjunto de 25 pacientes de uma variante de MS foi selecionado aleatoriamente do banco de imagens do HCFMRP. Três modalidades de imagens foram coletadas para a avaliação da segmentação automatica (T1, T2-FLAIR e DTI), assim como a segmentação manual do especialista para cada paciente. Três métodos de segmentação multimodal automática de lesões foram analisados (Bayesiano, Frequentista e Agrupamento) afim de analisar a sensibilidade e especificidade de detecção de lesões na substância branca aparentemente normal (NAWM). Os resultados sugerem que o método de segmentação Bayesiano apresenta maior robustes e precisão na definição tanto de lesões visivelmente contrastantes em T1 e T2-FLAIR (i.e. lesões hipo e hiperintensas) assim como lesões da NAWM evidentes nos mapas quantitativos de DTI (FA e ADC). O erro associado à técninca automática de segmentação ficou em torno de 1.51 +- 0.51 % do volume total de lesões marcadas pelo especialista. Concluímos que o uso de ferramentas multimodais de segmentação de imagens MRI alcançou patamares razoáveis de detecção de lesões de MS, tornando assim uma ferramenta computacional hábil para uso no diagnóstico clínico. / Multiple sclerosis (MS) is a neurodegenerative disease that has gained great attention in the last decades, which magnetic resonance imaging (MRI) have shown as an important tool for the disease evaluation. However, one of the main challenges is guaranteeing greater lesion detection sensitivity and specificity in the whole central nervous system (CNS) and thus classify the different variants of MS, which aids in decision making for pharmacological treatment. In the last decades, the diffusion-weighted imaging (DWI) technique, especially the diffusion tensor imaging approach (DTI), has been evidenced with great potential for the study of MS, presenting a significant improvement for the detection of lesions even in early stages of MS. Hence, the techniques of image processing are constantly improving in order to be adapted on a multimodal image evaluation. In this study, the development of a multimodal digital image processing technique to provide a viable solution to the MS imaging routine was focused. A set of 25 patients from a MS variant was randomly selected from the HCFMRP imaging database. Three MR imaging modalities were collected for the evaluation of our automatic segmentation (T1, T2-FLAIR and DTI), as well as manual segmentation of the specialist for each patient. Three methods of automatic multimodal segmentation of MS lesions were analyzed (Bayesian, Frequentist and Clustering) in order to analyze the sensitivity and specificity of lesion detection in the apparently normal white matter (NAWM). The results suggest that the Bayesian segmentation method presented greater robustness and precision in the definition of visibly contrasting lesions in T1 and T2-FLAIR (i.e. hypo and hyperintense lesions) as well as NAWM lesions that are evident in quantitative DTI (FA and ADC). The error associated with the automatic segmentation technique was around 1.51 +- 0.51 % of the total lesion volume being evaluated by the a specialist. We conclude that the use of multimodal MRI images can be used in an automatic segmentation tools, reaching reasonable levels of MS lesion detection, thus making it a useful tool for clinical diagnosis.
659

Caracterização por ressonância magnética nuclear de Na β\" alumina hidratada / Characterization of Na β alumina by nuclear magnetic resonance

Yara Galvão Gobato 14 August 1989 (has links)
Neste trabalho, estudamos a dependência com a temperatura dos tempos de relaxação nuclear T1 e T2 do 1H em policristais de Na &#946;\" alumina hidratada, no intervalo de temperatura de 255<T<540K, em 24,5MHz . Três amostras em pó foram selecionadas para medidas de RMN: duas puras e uma dopada com Fe (500ppm em peso). A presença de impurezas magnéticas nessas amostras foi observada através de espectros de Ressonância Paramagnética Eletrônica. Estudamos também a liberação de moléculas de água em função da temperatura pela técnica de TGA (Thermal Gravimetric Analysis). O sinal de RMN observado no intervalo de temperatura de 258<T<423K foi associado a moléculas de água fracamente ligadas enquanto que o sinal observado em temperaturas superiores foi associado a moléculas fortemente ligadas, provavelmente localizadas no plano de condução. Nossos resultados mostram que a hidratação o comportamento em função da temperatura dos tempos de relaxação nuclear são consideravelmente afetados pela presença de impurezas magnéticas / Proton NMR relaxation times T1 and T2 were measured on hydrated polycrystalline Na &#946; alumina in the temperature range 255<T<540K at 24.5MHz In order to get some feeling for the temperature at which water would leave the sample a thermal gravimetric analysis (TGA.) was also performed. Three powder samples, two pure and one iron doped (500ppm nominal), with particle diameters of 150-250micrômetros were selected for NMR measurements. Paramagnetic impurities were detected by EPR studies. Our results suggest that loosely bound water produces the NMR signal at temperatures lower than 423K while more tightly bound water, probably in the conduction planes, is predominant at higher temperatures. The relaxation time measurements show that magnetic impurities affect considerably the temperature dependence
660

Ressonância magnética detectada eletricamente em diodos de Alq3 / Electrically detected magnetic resonance of Alq3 based diodes

George Barbosa da Silva 02 September 2004 (has links)
Ressonância magnética detectada eletricamente (RMDE) de banda-X (9 GHz) e de banda-K (24 GHz) foram usadas para estudar diversos diodos baseados em tris-8(hidroxiquinolinolato) de alumínio III (Alq3). A técnica de RMDE consiste, basicamente, em medir a variação da condutividade quando o sistema entra na condição de ressonância magnética; assim, é possível relacionar propriedades de transporte elétrico com as funções de onda das moléculas envolvidas no processo. Para este estudo foram confeccionados diodos eletroluminescentes e unipolares de multicamadas no Laboratoire d'Optoélectronique des Materiaux Moléculaire (LOMM), da École Polytechnique Fédérale de Lausane (EPFL), Suíça, pelo Dr. Frank Nüesch. Faz parte também deste trabalho a montagem experimental do sistema de RMDE de banda-K, onde a maior parte dos dados foram obtidos. O sinal de RMDE dos diodos unipolares, da ordem de 1E-6, é atribuído ao processo dependente de spin de saltos eletrônicos que ocorre próximo às interfaces. O sinal típico de RMDE dos diodos eletroluminescentes é mais intenso, da ordem de 1E-4, e é atribuído à ressonância de spin-1/2 na formação dos éxcitons. O espectro de RMDE, por meio de ajuste de curvas, pôde ser decomposto em duas gaussianas: uma com largura de linha pico-a-pico DHPP de 1,6 mT, independente do campo elétrico aplicado no dispositivo, e outra variando de 2,0 mT a 3,4 mT. A componente mais estreita se deve à ressonância do radical positivo de Alq3, enquanto que a componente mais larga àquela do negativo. O estudo da forma de linha e de sua dependência com o campo elétrico dos espectros de RMDE de diodos unipolares dão suporte à ambas as atribuições. Neste trabalho, a questão da eficiência quântica e da zona de recombinação também são discutidas. / Electrically Detected Magnetic Resonance (EDMR) at X-band (9GHz) and K-band (24 GHz) were used to investigate Alq3 based diodes. EDMR technique consists basically of measuring conductivity variation at magnetic resonance conditions; thus, it is possible to correlate electrical transport properties with wave functions of the molecules involved in the process. Electroluminescent and unipolar multilayer diodes were prepared in the Laboratoire d'Optoélectronique des Materiaux Moléculaire (LOMM), at on École Polytechnique Fédérale de Lausane EPFL, Switzerland by Dr. Frank Nüesch. The experimental setup of the K-band EDMR system, where most of the data were obtained, was also part of this work. The unipolar diodes EDMR signal is of the order of 1E-6 and is attributed to spin dependent hopping process close to the interfaces. The electroluminescent diodes typical EDMR signal is more intense, of the order of 1E-4 , and is attributed to exciton´s formation spin-1/2 resonance. The EDMR spectrum can be decomposed into two Gaussians: one with peak-to-peak line width (DHPP) of 1.6 mT, independent of the electrical field applied to the devices, and other one whit DHPP of 2.0 mT to 3.4 mT. The narrower component is due to the resonance of positive Alq3 radical, while the larger component is due to the negative. Both attributions are supported by the investigation of line shape and its dependence of electrical field in the unipolar diodes EDMR spectra. In this work, the quantum efficiency and the recombination zone issues are also discussed.

Page generated in 0.056 seconds