• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 368
  • 8
  • 1
  • Tagged with
  • 385
  • 385
  • 385
  • 239
  • 223
  • 69
  • 62
  • 48
  • 44
  • 42
  • 41
  • 41
  • 41
  • 37
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Estratégias para a determinação de minoxidil

Sousa, Rogério Adelino de 04 September 2009 (has links)
Made available in DSpace on 2016-06-02T20:34:18Z (GMT). No. of bitstreams: 1 2757.pdf: 3606841 bytes, checksum: 1cbaf9d57ef931332c3b9f278a479c5a (MD5) Previous issue date: 2009-09-04 / Universidade Federal de Sao Carlos / In this work methods for determining minoxidil (MX) in commercial samples and electrolytes of synthetic plasma and urine are presented. The minoxidil is a pharmaceutical whose blood vessel dilation property is used in the treatment of the Arterial Hypertension and in the treatment of the Alopécia Areata. Three commercial samples were analyzed, the Regaine® (Pharmacia, USA) and the magistral formulation (Porto Bianco, Brazil) both are topical use solutions, in a mixture of ethanol and propilenoglicol as vehicle, containing 2 % (20 mg mL-1) and 5 % of minoxidil (50 mg mL-1) respectively, and Loniten® (Rhodia, Brasil) containing 10 mg of MX per tablet. Three proposals for the determination of minoxidil in commercial samples and electrolytes of synthetic plasma and urine were considered. The first procedure was the determination of MX in the samples using flow injection analysis with spectrophotometric detection in two setups. For the setup procedure using single line with a wavelength of 400 nm, which can quantify the MX present in samples, showing recovery values of 99.7 and 104.8 % for Loniten® and the Regaine® respectively, and 102.5 % for the magistral sample. In merging-zones setup, the detection was in 345 nm, the MX was determined in the samples with recovery 101.3 % for Loniten® and 99.8 % to Regaine® and 103.7 % for the magistral. For both configurations, all the results from flow agree with the labeled values and the results from the chromatographic method (comparative method) in 95 % confidence (t-Student test). In the second procedure, an electroanalytical determination of MX is described using two composite electrodes, the graphite-polyurethane (GPUE) and graphite-silicone rubber (GSRE). Cyclic voltammetry was used to study the electroactive area of electrodes (GPUE = 0.093 cm2; GSRE = 0.089 cm2), the diffusion coefficient of MX (in order of 8.0 x10-6 cm2 s-1) and to study the mechanism of electro-oxidation of MX of which involves one electron per proton. With the support of analytical curves were determined the levels of MX in the samples by different voltammetric techniques; cyclic voltammetry (CV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV). The recovery values are in the range between 96.0 and 110 %, depending on the sample and the voltammetric technique. The electrochemical impedance spectroscopy showed that the mass transport is controlled by diffusion and also there is a weak and reversible adsorption that for both the electrodes. The third method describes the determination of MX and furosemide (FR) using high performance liquid chromatography (HPLC) with spectrophotometric detection. The wavelengths of 275 and 285 nm were for the detection of FR and MX respectively. The mobile phase used was methanol/triethylamine (99:1, V/V) in the flow rate of 0.5 mL min-1. The column used was a C18 Supelco®. The recoveries were 97.7 and 102.4 % for Loniten® and Lasix® respectively. Finally is presented the characterization of the product of oxidation of MX. The informations obtained from infrared spectroscopy technique, were compared with results obtained by nuclear proton magnetic resonance. Two structures were proposed as product of redox reaction between the MX and KMnO4, the desoximinoxidil and another new structure. / No presente trabalho, são apresentados métodos para a determinação minoxidil (MX) em amostras comercias e eletrólitos de plasma e urina sintéticos. O MX é um fármaco que, devido à sua propriedade vasodilatadora, é usado no tratamento da Hipertensão Arterial e no tratamento da Alopécia Areata (calvice). Foram analisadas três amostras comerciais, Regaine® (Pharmacia, EUA), formulação de uso tópico manipulada pela Farmácia de Manipulação Porto Bianco (São Carlos, Brasil) e o Loniten® (Rhodia, Brasil), sendo o primeiro e o segundo soluções de uso tópico contendo 2 % (20 mg mL-1 m/v) e 5 % (50 mg mL-1 m/V) de MX, respectivamente; o terceiro medicamento é apresentado em forma de comprimidos contendo 10 mg de minoxidil, o qual é utilizado no tratamento da hipertensão arterial. Também foram analisados os teores de MX contido nos eletrólitos do plasma e da urina artificiais.Nesse trabalho foram propostas três metodologias para a determinação do MX nas amostras. O primeiro procedimento foi a determinação de MX nas amostras usando análise em fluxo com detecção espectrofotométrica em duas configurações diferentes, as quais monitoraram a formação de um produto amarelado formado a partir da reação entre MX e HNO2 formado in situ. A primeira configuração foi de linha única, com detecção no comprimento de onda de 400 nm, na qual foi possível quantificar o MX presente nas amostras, com recuperações de 99,7 e 104,8 % para o Loniten® e o Regaine®, respectivamente, e 102,5 % para a amostra manipulada. Na segunda configuração, de zonas coalescentes e detecção 345 nm, o MX foi determinado nas amostras com recuperação entre 101,3 % para o Loniten®, 99,8 % para o Regaine ® e 103,7 % para o Manipulado. Observou-se, para ambas as configurações, que todos os resultados do método de análise em fluxo concordam com os valores rotulados das amostras analisadas e com os resultados do método cromatográfico (método comparativo), em 95 % de confiança (teste t-Student). No segundo método, é descrita a determinação eletroanalítica de MX usando dois eletrodos compósitos de grafite-poliuretana (GPUE) e grafiteborracha de silicone (GSRE). Foi usada voltametria cíclica para o obtenção da área eletroativa dos eletrodos (GPUE = 0,093 cm2; GSRE = 0,089 cm2), do coeficiente difusão do MX (na ordem de 8,0x10-6 cm2 s-1) e para estudo do mecanismo da eletro-oxidação da MX, que é de um elétron por próton. Com o auxílio das curvas analíticas, foram determinados os teores de MX contidos nas amostras por diferentes técnicas voltamétricas, voltametria cíclica (CV), voltametria de onda quadrada (SWV) e voltametria de pulso diferencial (DPV), usando ambos os eletrodos. Os valores de recuperação estão no intervalo entre 96,0 e 110 %, dependendo da amostra e da técnica voltamétrica. A espectroscopia de impedância eletroquímica descreveu qual o circuito elétrico foi equivalente à eletro-oxidação do minoxidil e, ainda, mostrou que há adsorção fraca e reversível para ambos os eletrodos. O terceiro método descreve a determinação de MX e furosemida (FR), usando cromatografia líquida de alta eficiência (HPLC) com detecção espectrofotométrica. Os comprimentos de onda de detecção foram 275 e 285 nm para a FR e o MX, respectivamente. A fase móvel usada foi metanol/trietilamina (99:1; V/V) na vazão de 0,5 mL min-1. A coluna usada foi uma C18 da Supelco®. As recuperações foram 97,7 e 102,4 % para o Loniten® e o Furosem®, respectivamente. Finalmente, é apresentada a caracterização do produto de oxidação do MX. Para a caracterização, foi usada a espectroscopia de infravermelho e as informações obtidas foram comparadas com os resultados obtidos na ressonância magnética nuclear de prótons. Foram propostas, através da técnicas IR e RMN, duas estruturas resultantes da reação redox entre o MX e o KMnO4, o desoximinoxidil e uma outra estrutura, inédita na literatura o 3,5-dióxido-2,4- dinitro-6-piperidinopirimidina.
212

Estudo e aplicações das técnicas de RMN HR-MAS e DOSY em plantas e extratos de plantas da ordem Rutales. / Study and application of HS-MAS and DOSY NMR techniques in plants and plants extract from rutales order.

Vizzotto, Lucinéia 23 June 2004 (has links)
Made available in DSpace on 2016-06-02T20:34:38Z (GMT). No. of bitstreams: 1 TeseLV.pdf: 6603184 bytes, checksum: 01e1859f6dba5e37f943c2c05f4651b9 (MD5) Previous issue date: 2004-06-23 / Universidade Federal de Minas Gerais / This work describes the implementation of two recent techniques in NMR - DOSY e HR-MAS as a tool for the analysis of natural products mixture and in leaves of Citrus, respectively. The work begun with the technique DOSY, in which a known mixture of two natural products was employed to implement the technique and optimise the experiments of DOSY, DOSY-COSY and DOSY-HSQC. After that, the DOSY experiments was employed in a group of natural products mixtures, in which the technique applicability was assessed. The second part of the work was carried out by the implementation of HR-MAS technique with the experimental conditions optimisation and the technique evaluation in the study of Citrus leaves. The evaluation of the technique was carried out by the distinction among six Citrus sinensis varieties, as the indicator for the defence substances present in leaves of Citrus sinensis grafted in Citrus limonea and the detection and identification of the defence substances in leaves of Citrus spp under the plague attack. / O presente trabalho relata a implementação e a aplicação de duas técnicas relativamente recentes em RMN - DOSY e HR-MAS como ferramentas na análise de produtos naturais em mistura e em folhas de Citrus, respectivamente. O trabalho iniciou-se com a técnica DOSY, em que uma mistura conhecida de dois produtos naturais foi empregada para implementar a técnica e otimizar os experimentos de DOSY, DOSY-COSY e DOSY-HSQC. Posteriormente, foram realizados experimentos de DOSY em um conjunto de misturas de produtos naturais, no qual a aplicabilidade da técnica foi avaliada. A segunda parte do trabalho foi realizada com a técnica HR-MAS, que se iniciou com sua implementação, teve continuidade com a otimização das condições experimentais e foi finalizada com a avaliação de sua potencialidade como uma ferramenta na análise de folhas intactas de Citrus. Para isto a técnica foi avaliada quanto à distinção entre seis variedades de Citrus sinensis, à indicação de substâncias de defesa presentes em Citrus sinensis enxertado em Citrus limonea e à detecção e identificação de substâncias de defesa presentes em folhas de Citrus spp sob o ataque de pragas.
213

Applications of NMR techniques: Hyphenations (LC-SPENMR), affinity (DOSY) and NOE based (STD and Tr-OESY) to probe the binding interactions of ligands (synthetic and natural) towards protein

Ahmad, Sheraz 17 January 2014 (has links)
Made available in DSpace on 2016-06-02T20:34:49Z (GMT). No. of bitstreams: 1 5686.pdf: 10016184 bytes, checksum: e6a42772f0db7983f4cc9525851f9c5b (MD5) Previous issue date: 2014-01-17 / Universidade Federal de Sao Carlos / O foco principal desse trabalho foi a implementação, otimização e aplicações práticas de métodos de ressonância magnética nuclear (RMN) com o propósito de avaliar as interações entre moléculas de diferentes massas molares, sendo que essas técnicas foram implementadas pela primeira vez no laboratório de RMN do DQ-UFSCar. Existem várias abordagens que podem ser utilizadas com esse propósito, e dentre elas, destacamos: STD NMR, Tr-NOESY, WaterLOGSY, SALMON, INPHARMA, DOSY, SAR. Esses métodos são muito úteis para detectar mudanças de comportamento, a nível molecular, quando adicionamos macromoléculas em um meio contendo somente micromoléculas. O entendimento desse comportamento molecular ajuda a desvendar sistemas complexos de interações moleculares existentes no corpo humano, e que, são muito importantes para o descobrimento de novos medicamentos. O primeiro passo para a implementação das técnicas foi a utilização da proteína de soro bovino (do inglês BSA) e proteína de soro humano (do inglês HSA) como fonte de macromoléculas e micromoléculas orgânicas isoladas da fração etanólica do extrato bruto (1 mg) de Rauia resinous e da fração acetato de etila de Strypnodendron polyphyllum, utilizando cromatografia líquida de alta eficiência, extração por fase sólida e a ressonância magnética nuclear (CLAE-EFS/RMN) para a completa elucidação estrutural quando necessário. As técnicas utilizadas foram: saturation transfer difference (STD), transfer nuclear Overhauser spectroscopy (Tr-NOESY) e STD-TOCSY (total correlation spectroscopy). Essa mesma metodologia além de representar um importante mecanismo para avaliar as interações entre moléculas, também pode ser utilizada para outras matrizes variando tanto as macro quanto as micromoléculas. / The main focus of this work was the implementation, optimization and practical applications of nuclear magnetic resonance (NMR) methods for the purpose of evaluating the interactions between molecules of different masses, and these techniques were implemented for the first time in the laboratory NMR DQ - UFSCAR. There are a number of ligand-based screening approaches available, such that, STD NMR, Tr-NOESY, WaterLOGSY, SALMON, INPHARMA, DOSY, SAR by NMR etc. These methods are sensitive towards the perturbations as results of the macromolecular addition in a medium containing the small molecules. The molecular understanding of this behavior helps to uncover the complex systems of molecular interactions existing in the human body, which are very important for the discovery of new medicines. In the first step while implementing these techniques, Bovine Serum Albumin (BSA) and Human Serum Albumin (HSA) as a source of organic macromolecules were used. While, for the small organic molecules, a 1 mg crude extract from the hydroethanolic fraction of the Rauia resinous and ethyl acetate fraction of Strypnodendron polyphyllum was utilized, however, for the complete structural characterization, solid phase extraction following high-pressure liquid chromatography in an integrated fashion and then nuclear magnetic resonance (LC-SPE/NMR) was employed when necessary. On the other hand, the ligand screening techniques used were the saturation transfer difference (STD), Nuclear Overhauser Transfer Effect SpectroscopY (Tr- NOESY), Diffusion-Order Spectroscopy (DOSY) and STD- TOCSY (TOtal Correlation SpectroscopY). More importantly, this methodology also represents an important mechanism to evaluate the interactions between molecules or the first hand detection of the active constituents/inhibitors, which can also be used for other matrices varying both the macro and the small molecules.
214

Resolução de estruturas de proteínas utilizando-se dados de RMN a partir de um algorítmo genético de múltiplos mínimos / Resolution of Protein Structures Using NMR Data by Means of a Genetic Algorithm of Multiple Minima

Marx Gomes Van der Linden 15 April 2009 (has links)
Proteínas são macromoléculas biológicas formadas por polímeros de aminoácidos, as quais estão envolvidas em todos os processos vitais dos organismos, compreendendo um amplo leque de funções. A espectropia por Ressonância Magnética Nuclear (RMN) é, ao lado da difração de raios-X em cristais, uma das duas principais técnicas experimentais capazes de permitir a elucidação da estrutura de proteínas em resolução atômica. A predição de estruturas protéicas utilizando informações experimentais de RMN é um problema de otimização global com restrições. O GAPF é um programa que utiliza um Algoritmo Genético (AG) desenvolvido para predição ab initio -- isto é, para determinação da estrutura de uma proteína apenas a partir do conhecimento de sua seqüência de aminoácidos -- utilizando uma abordagem de múltiplos mínimos, baseada em uma função aptidão derivada de um campo de força molecular clássico. Neste trabalho, é descrito o GAPF-NMR, uma versão derivada do GAPF, que utiliza restrições experimentais de RMN para auxiliar na busca pelas melhores estruturas protéicas correspondentes a uma seqüência dada. Cinco versões diferentes do algoritmo foram desenvolvidas, com diferentes variações na maneira como a função de energia é calculada ao longo da execução. O programa desenvolvido foi aplicado a um conjunto-teste de 7 proteínas de estrutura já conhecida e, para todas elas, foi capaz de chegar a uma estrutura com o enovelamento correto ou aproximado. Foi observado que as versões do algoritmo que aumentam progressivamente a região da proteína usada no cálculo de energia tiveram desempenho superior às demais, e que a abordagem de múltiplos mínimos foi importante para a obtenção de bons resultados. Os resultados foram comparados aos descritos para o GENFOLD -- que é, até o momento, a única implementação alternativa conhecida de um AG para o problema de predição de estruturas a partir de dados de RMN -- e a versão atual do GAPF-NMR se mostrou superior ao GENFOLD na determinação de duas das três proteínas do conjunto-teste deste. / Proteins are biological macromolecules comprised of amino acid polymers that play a wide range of biological roles involved in every process of living organisms. Together with X-ray diffraction, Nuclear Resonance Spectroscopy (NMR) is one of the two main experimental techniques that are capable of delivering atomic-level resolution of protein structures. Prediction of proteic structures using experimental information from NMR experiments is a global optimization problem with restraints. GAPF is a computer program that uses a Genetic Algorithm (GA) developed for ab initio prediction -- the determination of the structure of a protein from its amino acid sequence only -- using a multiple minima approach and a fitness function derived from a classic molecular force field. The work presented here describes GAPF-NMR, an alternate version of GAPF that uses experimental restraints from NMR to support the search for the best protein structures that correspond to a given sequence. Five different versions of the algorithm have been developed, each with a variation on how the energy function is calculated during the course of the program run. GAPF was tested on a test set comprised of 7 proteins with known structure and it was capable of achieving a correct or approximate fold for every one of these proteins. It was noted that the versions of the algorithm that progressively increase the area of the protein used in the energy function have performed better than the other versions, and that the multiple minima approach was important to the achievement of good results. Results were compared to those obtained by GENFOLD -- to the moment, the only known alternate implementation of a GA to the problem of protein structure prediction using NMR data -- and the current version of GAPF was shown to be superior to GENFOLD for two of the three proteins that compose its test set.
215

Desenvolvimento da técnica de precessão livre no estado estacionário para aumento da razão sinal ruído em espectros de RMN de alta resolução / Use of steady state free precession (SSFP) to enhance signal to noise ratio in high resolution NMR

Poliana Macedo dos Santos 16 March 2009 (has links)
Neste trabalho realizou-se uma analise detalhada das vantagens e desvantagens da sequencia de Precessao Livre no Estado Estacionario (Steady State Free Precession - SSFP) para aquisicao rapida de espectros de Ressonancia Magnetica Nuclear (RMN) de 13C. O regime de SSFP e obtido atraves da aplicacao de um trem de pulsos de mesma fase, duracao e intensidade, separados por um intervalo de tempo (Tp) menor que os tempos de relaxacao longitudinal (T1) e transversal (T2) da amostra. Nestas condicoes e possivel acumular dezenas de espectros por unidade de T1, proporcionando um incremento significativo na razao sinal/ruido (s/r) do espectro. Ao comparar os resultados obtidos com as sequencias de SSFP e convencional (pulsos de 90 graus e T 5T1 p >= ), verificou-se que a SSFP apresentou um ganho medio de 30 vezes no tempo de analise para uma mesma s/r. No entanto, os espectros obtidos com a SSFP apresentam anomalias de fase e amplitude do sinal, decorrente da refocalizacao da magnetizacao na forma de um eco de spin. Comparou-se tambem a SSFP com a sequencia padrao usada para obtencao de espectros de 13C, que utiliza pulsos de 30 graus e Tp = 1.38s. Neste caso os ganhos da SSFP foram menores (5,5 vezes no tempo de analise para uma mesma s/r) verificando que a sequencia padrao utiliza a vantagem da SSFP (Tp < T1, T2). A formacao do eco e, consequente das anomalias de fase nao sao observadas na sequencia padrao, pois a aquisicao do sinal e truncada em 0,9s, e a ciclagem de fase dos pulsos reduz a formacao do eco, por levar a uma perda de coerencia do sinal SSFP. Neste trabalho tambem analisou-se os metodos propostos por Rudakov, Freeman e Hill e Schwenk para supressao destas anomalias nos espectros de RMN 13C quando adquiridos no regime de SSFP. Os resultados demonstraram que a aplicacao destas metodologias proporciona uma melhora significativa na qualidade do espectro. No entanto, verificou-se que nenhum metodo foi capaz de suprimir totalmente as anomalias de fase e amplitude do sinal. / It was performed a detailed analysis of the advantages and disadvantages of Steady State Free Precession (SSFP) sequence for a rapid acquisition of 13C Nuclear Magnetic Resonance (NMR) spectra. The SSFP regime is obtained by the application of a pulse train with the same phase, duration and intensity, separated by a time interval (Tp) shorter than the transverse (T2) and longitudinal (T1) relaxation times. In these conditions it is possible to accumulate tens of spectra per units of T1, providing a significant increase in the spectrum signal-to-noise ratio (s/n). By comparing the spectra obtained by SSFP and conventional pulse sequence (90 degree pulse and T 5T1 p >= ) it was noted that SSFP shows an average gain of 30 times in analysis time for the same s/n. However, the SSFP spectra show phase and intensity anomalies due to the refocusing of the magnetization, generating a spin echo. We also compared the SSFP with the standard 13C pulse sequence, that uses a 30 degree pulses and Tp = 1.38 s. In this comparison the SSFP gain were small (5,5 times in analysis time for the same s/n), because the standard sequence also uses the advantage of SSFP (Tp < T1, T2). The echo signal and the phase anomalies are not observed in the standard sequence because the signal acquisition is truncated at 0.9s and the cycling of the pulse phase, that partially destroy the SSFP coherence. We also analyzed the methods proposed by Rudakov, Freeman and Hill and Schwenk to suppress those anomalies in the 13C NMR spectrum when acquired in SSFP regime. The results showed that the application of these methodologies provides a significant improvement in the spectrum quality. However, it was verified that none of the methods were able to completely eliminate the phase and intensity anomalies.
216

Determinação de parâmetros físico-químicos em laranjas Valência por métodos não-destrutivos / Determination of physico-chemical parameters in oranges Valencia for methods non-destructive

Borba, Karla Rodrigues [UNESP] 20 July 2016 (has links)
Submitted by KARLA RODRIGUES BORBA null (borbakr@gmail.com) on 2016-09-20T23:38:38Z No. of bitstreams: 1 Dissertação Karla Borba FINAL.pdf: 1640601 bytes, checksum: d248911e99e0c55bcfeeb7cf07a3ab49 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-09-22T20:31:44Z (GMT) No. of bitstreams: 1 borba_kr_me_arafcf.pdf: 1640601 bytes, checksum: d248911e99e0c55bcfeeb7cf07a3ab49 (MD5) / Made available in DSpace on 2016-09-22T20:31:44Z (GMT). No. of bitstreams: 1 borba_kr_me_arafcf.pdf: 1640601 bytes, checksum: d248911e99e0c55bcfeeb7cf07a3ab49 (MD5) Previous issue date: 2016-07-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivo: Alguns atributos em sua composição química e física, como teor de sólidos solúveis (SST), pH (potencial hidrogeniônico), ácidos orgânicos, açúcares e cor são utilizados como parâmetros na aferição da qualidade de frutas. Os métodos utilizados, nos dias atuais, para a análise da qualidade destes produtos são invasivos, que demandam tempo, muitas amostras, reagentes e geram resíduos. Técnicas não destrutivas, como a espectroscopia no infravermelho e de ressonância magnética nuclear, têm sido propostas para avaliar qualidade em frutas e hortaliças. Este projeto teve como objetivo: desenvolver um modelo de calibração, a partir da espectroscopia de infravermelho de médio e próximo, e ressonância magnética com o auxílio das ferramentas quimiométricas PCA (análises de componentes principais) e PLS (Regressão em mínimos quadrados parciais) com a utilização do programa computacional Pirouette versão 4.5, para estimar parâmetros físico-químicos da qualidade de laranjas da variedade ‘Valência’. Métodos: Foram coletadas um total de 450 laranjas de cultivo comercial no interior de São Paulo, transportadas para a Embrapa Instrumentação, São Carlos, SP e em laboratório foram selecionadas, higienizadas e sanitizadas. Em seguida foram realizadas análises espectroscópicas de infravermelho médio (MIR) e próximo (NIR) e de ressonância magnética nuclear (RMN). Logo após realizadas as análises não destrutivas as laranjas foram analisadas com métodos de referência para os parâmetros de qualidade. Os sinais espectroscópicos foram processados e os modelos de predição foram construídos. Com os sinais de NIR e MIR foram desenvolvidos modelos PLS para determinação de: SST, pH, massa fresca, vitamina C, ácido cítrico e açucares. Para os sinais de decaimento de RMN foram construídos modelos para SST, pH e massa fresca. Resultados: Para a predição de SST o modelo PLS – NIR mostrou melhor resultado, com SEP 0,74 °BRIX e coeficiente de correlação de 0,75. O parâmetro que apresentou melhor aplicação com a técnica de RMN-dt foi para determinação de massa fresca, com SEP 21,41 gramas e r = 0,82. A determinação do pH foi mais precisa com o modelo PLS-MIR, onde observou-se SEP de 0,20 e r = 0,86. Para a predição de vitamina C e ácido cítrico tanto o NIR quanto o MIR resultaram em modelos com aplicabilidade. O modelo mais preciso foi o desenvolvido com sinas de MIR, com coeficiente de correlação de Pearson (r) de 0,81 e erro quadrático médio de predição (RMESP) de 7,51 para vitamina C e 0,82 e 3,36 para ácido cítrico. Em relação a predição de açúcares o NIR não resultou em modelos precisos. Todavia, a utilização de MIR para a predição de sacarose, glicose e açúcares totais apresentaram baixos erros de predição 11,69, 7,79 e 24,28 (g L-1) e coeficientes de correlação de forte a moderado. Conclusão: A aplicação de espectroscopia na determinação de parâmetros de qualidade mostrou-se uma possível alternativa na análise de qualidade de laranjas sem que seja necessária a destruição das amostras. / Objective: Some attributes in their chemical and physical composition, as soluble solids content (SSC), pH (hydrogen potential), organic acids, sugars and color are used as parameters in measuring the quality of fruit. The methods used nowadays, to analyze the quality of these products are invasive, requiring time, many samples, reagents and generate waste. Nondestructive techniques such as infrared spectroscopy and nuclear magnetic resonance, have been proposed to evaluate quality in fruits and vegetables because they allow rapid implementation of measurements without sample preparation. This project aimed to: develop a calibration model by near ande mid-infrared spectroscopy and nuclear magnetic resonance with the aid of chemometric tools PCA (principal component analysis) and PLS (regression in partial least squares) with use of the computer program Pirouette version 4.5, to estimate physical-chemical parameters of quality oranges from ‘Valencia’ variety. Methodology: A total of 450 commercial cultivation oranges were collected in São Paulo, transported to Embrapa Instrumentation, São Carlos/SP, and in laboratory were selected, cleaned and sanitized. Then spectroscopic analysis near (NIR) and mid-infrared (MIR), and nuclear magnetic resonance (NMR) were made. After performed the non-destructive analysis, the oranges were analyzed with reference methods for quality parameters. Spectroscopic data were processed and prediction models were developed to determinith MIR and NIR signal PLS models were developed to determine SSC, pH, fresh weight, vitamin C, citric acid and sugars. For the NMR signal decay models were constructed to SSC, pH and fresh weight. Results: For SSC prediction PLS model - NIR showed better results, with RMSEP (mean squared prediction error) 0.74 °BRIX and 0.75 correlation coefficient. The parameter that showed better application with DT- NMR technique was to determine fresh weight with RMSEP 21.41 grams and r = 0.82. The determination of pH was more accurate with the PLS-MIR model where there was RMSEP 0.20 and r = 0.86. For the prediction of vitamin C and citric acid as both the MIR NIR models resulted in applicability. The most accurate model was developed with MIR, with Pearson's correlation coefficient (r) of 0.81 and RMESP of 7.51 for vitamin C and 0.82 and 3.36 for Citric acid. Regarding the prediction of sugars NIR did not result in accurate models. However, the use of MIR for the prediction of sucrose, glucose and total sugars were low prediction errors 11.69, 7.79 and 24.28 (g L-1 ) and strong correlation coefficients to moderate.Conclusion: The application of spectroscopy to determining quality parameters proved to be a viable alternative in quality analysis oranges without destruction of samples.
217

Humanização em salas de exames de ressonância magnética com enfoque no design para experiência / Humanization in MRI exams rooms with a focus on experience design

Dallarosa, Fernanda Bertoni January 2015 (has links)
Esta pesquisa aborda o ambiente da sala de exames de Ressonância Magnética (RM), um dos principais exames de diagnóstico médico por imagem. A partir de um estudo de caso, usuários internos (funcionários) e usuários externos (pacientes) de um Estabelecimento Assistencial de Saúde (EAS) expressaram suas percepções acerca da experiência com o referido exame por meio de entrevista e questionários formulados com o apoio da avaliação pós-ocupação (APO). Observou-se que as mulheres são as principais desistentes na realização dos exames, alegando claustrofobia. Também foi observado que o próprio aparelho de RM causa emoções contraditórias nos pacientes, ora despertando medo, ora, satisfação. Fica claro que o ambiente é fator de influência das emoções e que os dados coletados nessa pesquisa serão norteadores para projetos futuros, como, por exemplo, uma proposta de design do ambiente de exames com foco na humanização e com intenções de melhorar a experiência dos examinados com o procedimento. / This research addresses the MRI examination room environment (MRI), which is considered one of the main medical imaging tests. Using a case study methodology, both internal users (employees) and external users (patients) were interviewed and were asked to express their perceptions regarding the experience with the procedure. The interview and questionnaires were based on the framework of postoccupancy evaluation (POE). It was observed that women are the main dropouts in MRI scans, claiming claustrophobia. It was also observed that the scanner itself is likely to evoke mixed emotions in patients, sometimes arousing fear and sometimes arousing satisfaction. This study makes it clear that the environment is a key factor in shaping emotions and that the data collected in this survey will serve as a guide for future projects, such as a proposal for design focusing on environmental humanization that aims at improving the experience with this medical procedure.
218

Desenvolvimento de instrumentação para o estudo de materiais magnéticos usando RMN com campo externo zero / Development of instrumentation for the study of magnetic materials using zero-field NMR

Alessandro Aguiar de Castro Sá 22 November 2005 (has links)
Este trabalho de mestrado teve por objetivo a recuperação de um espectrômetro de RMN de dupla-ressonância construído na década de 1980 para o estudo de materiais no estado sólido. Esse espectrômetro foi parcialmente destruído por um raio que atingiu o prédio do IFSC-USP em 2001, tendo sua parte digital inutilizada, a qual envolvia o gerador de pulsos, e o digitalizador e promediador de sinais. Este trabalho envolveu a instalação de uma placa geradora de pulsos e um osciloscópio digital, ambos comerciais, controlados por um computador executando programas elaborados por nosso grupo. Embora o espectrômetro permita a implementação de técnicas de RMN de alta resolução de dupla-ressonância para o estudo de materiais no estado sólido, os primeiros experimentos de RMN foram realizados com materiais magnéticos, os quais permitiram sua execução sem a utilização do magneto supercondutor. No momento, esse espectrômetro encontra-se em fase de aprimoramento e testes de desempenho e já tornou possível a obtenção de resultados importantes em materiais magnéticos / The objective of this work was to repair and upgrade a double-resonance NMR spectrometer assembled in the 80s for studying solid-state materials. In 2001 this instrument was damaged by an atmospheric discharge that destroyed its digital modules, i.e., the pulse generator, digitizer, and averager. The work reported on here involved installing a new pulse-generator board and a programmable digital oscilloscope, both commercially available. These are computer-controlled by software developed by our research group. Although the spectrometer allows the use of double resonance NMR techniques for studying solid-state materials, the first experiments were done with magnetic materials, which required no superconducting magnet. Presently, the spectrometer is still being tested and improved. Even so, it is already capable of yielding important data in the study of magnetic materials
219

Supressão de bandas laterais através da técnica de rotação da amostra em torno do ângulo mágico com frequência variável / Spinning sideband suppression by variable and low magic angle spinning

Ednalva Aparecida Vidoto 11 October 1995 (has links)
Em experimentos de Ressonância Magnética Nuclear (RMN) com Rotação da Amostra em Tomo do Ângulo Mágico (MAS), as bandas laterais são um problema comum na obtenção de espectros de alta resolução em sólidos. Em espectrômetros de alto campo magnético ou então, em sistemas que não dispõem de rotores de amostra de freqüência elevada, este problema é mais grave. Para facilitar a interpretação do espectro de alta resolução torna-se necessário suprimir estas bandas laterais. Nesta dissertação descrevemos um método simples de supressão das bandas laterais que consiste em variar a freqüência de rotação da amostra durante a aquisição do sinal, assim como, a instrumentação necessária para realizar esse experimento. Este método, que denominamos de Supressão das Bandas Laterais utilizando-se Freqüência de Rotação Baixa e Variável, baseia-se na dependência da posição das bandas laterais com a freqüência de rotação, reduzindo as coincidências entre suas posições durante a promediação, enquanto o sinal isotrópico permanece estável sempre no mesmo ponto do espectro. Para ilustrar a utilização dessa nova técnica, realizamos experimentos de RMN com o núcleo de 13C em amostras de hexametilbenzeno, tirosina, lignina e ácido húmico, e com o núcleo quadrupolar 79Br em amostras de KBr e NaBr + KBr / Sidebands in Magic-Angle-Spinning Nuclear Magnetic Resonance (MAS-NMR) experiments are a common problem for high field spectrometers or low spinning frequency systems. Although these sidebands may be used to gain information after they have been identified, it is necessary to eliminate then to simplify the interpretation of the spectra; we have recently succeeded in suppressing spinning sidebands by continuously varying the speed during the signal acquisition. This method, that we called variable low speed sideband suppression, relies on the speed dependent of the sideband positions. The purpose of this work is to describe a simple method and apparatus to suppress spinning sidebands in MAS-NMR experiments. The method allows a quick acquisition of the isotropic chemical shift spectra and works well even when the highest available spinning cannot clearly resolve the spinning sidebands. To illustrate the method, we present the 13C MAS-NMR spectra of a variety of sample acquired using cross-polarization and high power proton decoupling. Among the samples studied were: hexamethylbenzene, tyrosine, lignin and humic acid. And quadrupolar nuclei 79Br in the samples Kbr and NaBr + KBr
220

Estudo teórico de propriedades espectroscópicas de bases nitrogenadas e derivados de vitamina A em solução / Theoretical study of spectroscopic properties for nitrobases and vitamin A derivatives in solution

Oliveira, Guilherme Colherinhas de 23 March 2012 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-08-24T18:39:30Z No. of bitstreams: 2 Tese - Guilherme Colherinhas de Oliveira - 2012.pdf: 41954562 bytes, checksum: b2c7e39bdbf8d887462d338c56fcbd4f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Rejected by Luciana Ferreira (lucgeral@gmail.com), reason: Olhe a citação : Oliveira, Guilherme Colherinhas de. Estudo teórico de propriedades espectroscópicas de bases nitrogenadas e derivados de vitamina A em solução. 2012. 363 f. Tese (Doutorado em Física) - Universidade Federal de Goiás, Goiânia, 2012. on 2018-08-27T11:19:33Z (GMT) / Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2018-08-27T19:07:35Z No. of bitstreams: 2 Tese - Guilherme Colherinhas de Oliveira - 2012.pdf: 41954562 bytes, checksum: b2c7e39bdbf8d887462d338c56fcbd4f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2018-08-28T11:16:46Z (GMT) No. of bitstreams: 2 Tese - Guilherme Colherinhas de Oliveira - 2012.pdf: 41954562 bytes, checksum: b2c7e39bdbf8d887462d338c56fcbd4f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-08-28T11:16:46Z (GMT). No. of bitstreams: 2 Tese - Guilherme Colherinhas de Oliveira - 2012.pdf: 41954562 bytes, checksum: b2c7e39bdbf8d887462d338c56fcbd4f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2012-03-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / In this work we present a theoretical study for the optical absorption spectrum UV-VIS and nuclear magnetic resonance (NMR) parameters of molecules that forming the structure of the deoxyribonucleic acid (DNA): adenine, guanine, thymine and cytosine in aqueous solution and of aldehydes and carboxylic acids derivatives of vitamin A in solution of chloroform, acetonitrile, methanol and water. The Solvent effects are treated using a sequential methodology that combines Monte Carlo simulation and quantum mechanics calculations (S-MC / MQ). Effects of polarization of the reference molecules by the solvent are obtained iteratively assuring the convergence of the dipole moment in solution, with the atoms of the solvent molecules modeled by point charges. The results show that the polarization effect can give marked increases for the dipole moments of the reference molecules, especially in water, as compared with the results of gas phase. TD-DFT calculations for the vertical electronic transitions were performed with hybrid functionalities: B3LYP, PBE1PBE and BHandHLYP; and with long-range corrected functionals: CAM-B3LYP and LC-wPBE. For the isotropic magnetic shielding constants, GIAO-B3LYP results were obtained with several basis set functions: 6-311 ++ G (2d, 2p), AUG-cc-pVTZ, pcS-2, pcS-3 and AUG-pcS -2. The results obtained show the optical absorption spectrum variations between 6 and 28 nm for the nucleotide bases and between 13 and 80 nm for the derivatives of vitamin A with the functional type, whereas that for the NMR parameters of carbon atoms variations between 3 and 10 ppm with the choice of the basis set functions. However, the inclusion of the solvent polarization effects provides a reliable description for these electronic properties in solution, in comparison with available experimental results. The classical simulations were performed with the DICE program and the quantum calculations with the GAUSSIAN03 / 09 program. / Neste trabalho apresentamos um estudo teórico para o espectro de absorção óptica na região UV-VIS e para os parâmetros de ressonância magnética nuclear (NMR) das moléculas que compõe a base estrutural do ácido desoxirribonucleico (DNA): adenina, guanina, timina e citosina em solução aquosa e de aldeídos e ácidos carboxílicos derivados da vitamina A em solução de clorofórmio, acetonitrila, metanol e água. Os efeitos de solvente são tratados utilizando uma metodologia sequencial que combina simulação de Monte Carlo e cálculos de Mecânica Quântica (S-MC/MQ). Efeitos de polarização das moléculas de referência pelo solvente são obtidos iterativamente assegurando a convergência do momento de dipolo em solução, com os átomos das moléculas de solvente modelados por cargas pontuais. Os resultados mostram que o efeito da polarização pode dar aumentos substanciais para os momentos de dipolo das moléculas de referência, especialmente em água, quando comparado com os resultados de fase gasosa. Cálculos TD-DFT para as transições eletrônicas verticais foram realizados com funcionais híbridos: B3LYP, PBE1PBE e BHandHLYP; e com funcionais com correção de longo alcance: CAM-B3LYP e LC-wPBE. Para as constantes de blindagem magnética isotrópica, resultados GIAO-B3LYP foram obtidos com diferentes conjuntos de funções base: 6-311++G(2d,2p), AUG-cc-pVTZ, pcS-2, pcS-3 e AUG-pcS-2. Os resultados obtidos mostram para o espectro de absorção óptica na região do UV variações entre 6 e 28 nm para as bases nitrogenadas e na região do UV-VIS entre 13 e 80 nm para os derivados de vitamina A com o tipo de funcional, enquanto que para os parâmetros NMR de átomos de carbono variações de 3 a 10 ppm com a escolha do conjunto de funções base. Entretanto, a inclusão dos efeitos de polarização do meio fornece uma descrição realista para essas propriedades eletrônicas em solução, em comparação com resultados experimentais disponíveis. As simulações clássicas foram realizadas com o Programa DICE e os cálculos quânticos com o Programa GAUSSIAN03/09.

Page generated in 0.0622 seconds