• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 88
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 1
  • Tagged with
  • 93
  • 93
  • 72
  • 26
  • 24
  • 15
  • 14
  • 13
  • 12
  • 11
  • 11
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribuição para a funcionalidade e a segurança em ressonância magnética

Moraes, Luciano de January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica. / Made available in DSpace on 2012-10-20T12:02:05Z (GMT). No. of bitstreams: 1 194333.pdf: 2949848 bytes, checksum: a7282fef57b3415b8ba706a28566ade0 (MD5) / A imagem por ressonância magnética (IRM) apresenta no Brasil um crescente potencial de aplicações ainda não totalmente explorado. Por causa disto, torna-se necessário assegurar as condições da funcionalidade com o enfoque na qualidade da imagem, técnica e clínica, e da segurança ao paciente e funcionários envolvidos nos serviços de IRM. Este trabalho tem como objetivo, proporcionar um aporte para a Engenharia Clínica (EC) na gestão de tecnologia médico-hospitalar (GTMH), através da elaboração de uma proposta de metodologia que permita verificar as condições da qualidade da imagem e da segurança nos serviços de IRM e, de referencial teórico em futuras elaborações de procedimentos de ensaios. Primeiramente, discutem-se as características necessárias para a qualidade da imagem e, depois, abordam-se os aspectos de segurança, analisando-se a literatura técnica e a norma internacional IEC 60601-2-33:2002 (Particular requirements for the safety of magnetic resonance equipment for medical diagnosis). Com os resultados obtidos na aplicação da metodologia em um estabelecimento assistencial de saúde (EAS) de Santa Catarina, percebeu-se que a metodologia proposta mostra-se útil na avaliação qualitativa do uso dessa tecnologia, por fornecer um diagnóstico geral dos ensaios, calibrações, recursos humanos e políticas de segurança empregados pela instituição e, por permitir identificar ações para a melhoria desses serviços, caracterizando um dos aspectos da GTMH.
2

Estrutura tridimensional da crotamina extraída do veneno da cascavel Crotalus durissus terrificus utilizando ressonância magnética nuclear homonuclear

Fadel, Valmir [UNESP] 26 September 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-09-26Bitstream added on 2014-06-13T21:01:34Z : No. of bitstreams: 1 fadel_v_dr_sjrp.pdf: 3914657 bytes, checksum: 33f667f3dc51502de2df4a24d382b1cf (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
3

Anatomia da coluna vertebral torácica em auxílio de ressonância nuclear magnética

Imbelloni, Luiz Eduardo [UNESP] 19 January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-19Bitstream added on 2014-06-13T19:25:21Z : No. of bitstreams: 1 imbelloni_le_dr_botfm.pdf: 1083712 bytes, checksum: 1d2f66de73e838257e456cd7956ff1bd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Anestesiologistas freqüentemente realizam peridural torácica para os diversos tipos de cirurgia. A ressonância magnética de imagem tem estudado os nervos dentro do saco dural da cauda eqüina. Poucos estudos têm correlacionado a medula espinal com a dura-máter na região torácica. Punção acidental da dura-máter pode ocorrer durante tentativa de punção torácica e raramente cursa com lesão neurológica definitiva. O objetivo desta investigação, com ressonância magnética de imagem (RMI), é avaliar a distância entre a dura-máter e a medula espinal, em pacientes sem doenças da medula ou coluna vertebral nos 2º, 5º e 10º segmentos torácicos. Cinqüenta pacientes foram estudados com RMI realizada na posição supina. Corte sagital nos 2º, 5º e 10º segmentos torácicos foram medidos com aparelho 1.5 T com sistema super condutor (Gyroscan Intera, Philips Medical Systems, Best, The Netherlands). Em 10 pacientes foi medido o ângulo relativo à tangente no ponto de inserção na pele. A distância posterior da dura-máter até a medula espinal foi significativamente maior (Bonferroni’s valor-p<0,015) na região torácica média (5ª torácica = 5,808 ± 0,840 mm) do que na região torácica alta (2ª torácica = 3,909 ± 0,802 mm) e região torácica baixa (10a torácica = 4,129 ± 0,967 mm). Não foi encontrada diferença entre os interespaços T2 e T10 (Bonferroni’s p-values=0,225). Não foi observada correlação entre a idade a distância medida entre a dura-máter e a medula espinal (todos os valores de p ≥ 0,166). O ângulo da entrada da agulha em T2 foi observado valor de 9,00±2,49 graus, em T5 de 45,00±7,45 graus e em T10 de 9,50±4,17 graus. A correção do espaço pelo ângulo de entrada da agulha aumentou a distância entre a dura-máter e a medula nos três interespaços vertebrais. Este estudo demonstrou que existe um grande espaço na região posterior... / Anesthesiologists frequently give thoracic epidural blocks for a variety of surgeries. MRI has provided studies of the nerves (cauda equina) inside the dural sac. But there are only a few correlating the spinal cord with the duramater in the thoracic region. With the use of Magnetic Resonance Imaging (MRI), this study investigated the distance of the duramater to the spinal cord in patients without spinal or medullar disease at the 2nd, 5th and 10th thoracic segments. Fifty patients in the supine position were underwent MRI. Medial sagittal slices of the 2nd, 5th and 10th thoracic segments were measured for the relative distances through the 1.5 T super-conducting system (Gyroscan Intera, Philips Medical Systems, Best, The Netherlands). In ten patients the angles relative to the tangent at the insertion point on the skin was measured. The posterior dural-spinal cord distance is significantly greater the midthoracic region (5th thoracic = 5.808 ± 0.840 mm) than at upper (2nd thoracic = 3.909 ± 0.802 mm) and lower thoracic levels (10th thoracic = 4.129 ± 0.967 mm) (p<0.015). There were no differences between interspaces T2 and T10. There was no correlation between the age and the measured distance between the duramater and the spinal cord.
4

Achados na ressonância magnética em pacientes com cervicobraquialgia

Silva, Gilka Amélia Antunes da January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Saúde Pública / Made available in DSpace on 2012-10-23T04:55:52Z (GMT). No. of bitstreams: 1 245075.pdf: 1338616 bytes, checksum: c05f6e62350fd328f6336f75feb5d882 (MD5) / Esta pesquisa consiste em uma coorte histórica onde são selecionados 60 pacientes submetidos a exames de ressonância magnética da coluna cervical, que apresentavam como indicação clínica a cervicobraquialgia. O objetivo do trabalho é identificar, nestes exames, sinais de doença degenerativa da coluna cervical, nos pacientes em investigação clínica de cervicobraquialgia. A coleta dos dados foi realizada na base de dados da Clínica Imagem Centro Diagnóstico® localizada em Florianópolis. Dos exames selecionados 47 (78,3%) pertencem a pacientes do sexo feminino e 13 (21,7%) a pacientes do sexo masculino, com idade média de 44,4 anos. Foram avaliados neste estudo, estreitamento do forame neural (presente em 70% dos exames, predominando na faixa etária entre 46 e 80 anos com 92,3%), alterações degenerativas nas articulações uncovertebrais (redução do espaço articular e presença de osteófitos) onde se observou porcentagem de 100% entre 46 e 80 anos. Foram avaliados ainda, desidratação discal, redução do espaço discal e protrusão disco-osteofitária, sendo que a porcentagem de exames que apresentaram desidratação discal foi bastante elevada (86,7%). Estas alterações foram mais freqüentes entre 46 e 80 anos e o espaço discal mais envolvido, C5-C6. A hérnia discal, diferente das outras alterações encontradas, foi mais freqüente na faixa etária entre 24-45 anos, achado similar ao observado na literatura. Pode-se concluir que nos exames de pacientes com cervicobraquialgia analisados, os sinais de doença degenerativa presentes são: estreitamento do forame neural, alterações degenerativas nas articulações uncovertebrais, desidratação discal, redução do espaço discal, protrusão disco-osteofitária e hérnia, achados já consagrados na literatura.
5

Síntese, determinação da microestrutura e relação com as propriedades dos terpolímeros de etileno-propileno-1-penteno

Silva, Marco Antonio da January 2008 (has links)
Terpolímeros de etileno-propileno-1-penteno foram sintetizados empregando três sistemas catalíticos diferentes: rac-Et(Ind)2ZrCl2, Me2C(Cp)(Flu)ZrCl2 e o sistema suportado Cp2ZrCl2/MAO/SiO2 todos ativados com MAO. A razão de etileno e propileno foram variadas e duas concentrações de 1-penteno foram empregadas. Neste trabalho são apresentados os resultados qualitativos e quantitativos de caracterização destes terpolímeros através da técnica de ressonância magnética de carbono 13 (RMN de 13C) onde são apresentados os deslocamentos químicos observados e devidamente identificados, assim como a análise quantitativa das tríades, do comprimento médio das unidades consecutivas e das razões de reatividade. O efeito da adição de 1-penteno ao sistema etileno-propileno foi avaliado através dos resultados da atividade catalítica, incorporação de comonômero, propriedades térmicas, massa molar e propriedades mecânicas, para os três sistemas catalíticos em questão. Também foi avaliada a heterogeneidade de algumas amostras através do fracionamento por eluição com gradiente de temperatura (p-TREF). Para a atividade catalítica a ordem foi rac-EtInd2ZrCl2 > Cp2ZrCl2/MAO/SiO2 > i-Pr(Flu)(Cp)ZrCl2. O catalisador indenil foi o que proporcionou uma maior incorporação de termonômero, mostrando ser o catalisador mais eficiente para síntese de terpolímeros. Quanto ao catalisador suportado Cp2ZrCl2/MAO/SiO2, a incorporação de comonômero e termonômero foi bastante baixa e ele se mostrou inativo quando altas concentrações de propileno foram empregadas. O catalisador i-Pr(Flu)(Cp)ZrCl2 apresentou baixa atividade para a produção de copolímero etileno-propileno, e também não levou a formação de polímeros com concentração mais alta de propileno e terpolímeros. Com a análise de RMN de 13C foi possível caracterizar a estrutura do material, onde ficou demonstrado que ocorre uma competição entre propileno e o 1-penteno pela incorporação no polímero. À medida que aumenta a concentração de propileno no meio reacional, reduz-se a incorporação de 1-penteno nos terpolímeros, já para os copolímeros de propileno - 1-penteno, ocorre um aumento na incorporação de 1-penteno. A incorporação de propeno acarreta uma diminuição das unidades cristalizáveis de etileno, provocando um decréscimo na temperatura de fusão e massa molecular. Com concentrações mais altas de propileno ocorre um aumento das unidades cristalizáveis do propeno e, conseqüentemente, a cristalinidade aumenta. Análises dinâmico-mecânicas dos copolímeros e terpolímeros indicaram que o conteúdo de comonômero tem grande influência nas transições α e β. Para as propriedades mecânicas observou-se que a maior inserção de comonômero reduz a cristalinidade do material fazendo com que os terpolímeros apresentem um módulo menor do que os homopolímeros e também dos copolímeros, apresentando um comportamento elastomérico. / Series of ethylene (E), propylene (P) and 1-pentene (A) copolymers and terpolymers, differing in monomer composition ratio, were synthesized using (rac-Et(Ind)2ZrCl2/MAO), (Me2C(Cp)(Flu)ZrCl2/MAO and, (Cp2ZrCl2/MAO/SiO2/MAO) supported on silica impregnated with MAO as catalytic systems. The ratio of ethylene and propylene was varied from 0 to 100 and two concentrations of 1-pentene were employed. The catalytic activities at 25oC and atmospheric pressure were compared. A detailed study of ¹³C NMR chemical shifts, triad sequences distributions, monomer-average sequence lengths and reactivity ratios for the terpolymers is presented. The effect of the addition of 1-pentene to the ethylene-propylene was evaluated by the results of the catalytic activity, comonomer incorporation, thermal properties, mechanical properties and molecular weight. The heterogeneity of some samples was studied through the fractionation by elution with gradient of temperature (p-TREF). For the catalytic activity the order was rac-EtInd2ZrCl2 > Cp2ZrCl2/MAO/SiO2 >i-Pr(Flu)(Cp)ZrCl2. The indenyl catalyst presented the largest incorporation of termonomer, showing to be the most effective catalyst for synthesis of the terpolymers. The supported catalyst, Cp2ZrCl2/MAO/SiO2, presented an incorporation of termonomer quite low, and it was inactive when high concentrations of propylene were employed. The catalyst i-Pr(Flu)(Cp)ZrCl2 showed low activity in ethylene-propylene copolymerization at low propylene concentrations and it was inactive in terpolymerization. The 13C NMR analysis allowed to characterize the structure of the material., It was shown that there is a competition between propylene and 1-pentene for the incorporation into the polymer, when the propylene concentration increases there is a decrease of the 1-pentene concentration. The incorporation of propylene produces a reduction of the ethylene crystalline units, causing a decrease in the melting temperature and in the molecular weight. At higher concentrations of propylene there is an increase of the crystallizable units of propene and consequently an increase in the melting temperature. Dynamic-mechanical-thermal analyses of these copolymers and terpolymers showed that the comonomer content has great influence on the α- and β-transitions. For the mechanical properties it was observed that the increase in comonomer reduces the crystallinity of the material so that terpolymers have a lower module than homopolymers and copolymers and show an elastomeric behavior.
6

Alcalóides ciclopeptídicos

Oliveira, Leonardo Henrique de 26 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas, Programa de Pós-Graduação em Química, 2011 / Made available in DSpace on 2012-10-26T08:32:27Z (GMT). No. of bitstreams: 1 289267.pdf: 16336892 bytes, checksum: d930262d82fef26b78a8032be9e38109 (MD5) / O alcalóide ciclopeptídico franganina foi isolado da Discaria americana pertencente à família Rhamnaceae e teve sua estrutura elucidada através de técnicas de Ressonância Magnética Nuclear 1 D (1H, 13C) e 2 D ( COSY, HSQC, HMBC, NOESY). Além disso, a influência das ligações de hidrogênio na conformação do macrociclo foi verificada através do deslocamento químico e constantes de acoplamento em diferentes solventes (CDCl3, DMSO-d6, metanol-d4). Os dados de RMN como os deslocamentos químicos, constantes de acoplamento (ângulo diedro) e correlações bidimensionais permitiram estabelecer relações com a configuração dos centros quirais (estereoquímica dos carbonos C-3 e C-4) e com a conformação da molécula em solução. Além disso, foi feita a análise por difração de raios-X de um derivado da mesma, e pôde-se determinar a estereoquímica dos centros quirais (C-3 e C-4) do cristal obtido. Outros dados fornecidos dessa análise foram comparados com os de RMN. / The cyclopeptide alkaloid Franganine was isolated from Discaria americana belonging to the family Rhamnaceae and its structure was elucidated by NMR 1D (1H, 13C) and 2 D (COSY, HSQC, HMBC, NOESY) techniques. Moreover, the influence of hydrogen bonds in the macrocycle conformation was observed through chemical shifts and coupling constants in different solvents (CDCl3, DMSO-d6, and methanol-d4).NMR data, such as chemical shifts, coupling constants (dihedral angle) and two-dimensional correlations allowed to establish relations with the configuration of chiral centers (stereochemistry of the C-3 and C-4 carbons) and the conformation of the molecule in solution. Furthermore, the analysis done by x-ray diffraction and furnished the stereochemistry of the chiral centers (C-3 and C-4) crystal. Other data provided by the use of this analysis were compared with those obtained by NMR data.
7

Influência de efeitos estéricos na hidrólise ácida de o-alquil acetais do benzaldeído

Belarmino, Alexanders Tadeu das Neves January 2003 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências Físicas e Matemáticas. Programa de Pós-Graduação em Química. / Made available in DSpace on 2012-10-20T16:53:38Z (GMT). No. of bitstreams: 1 193376.pdf: 874126 bytes, checksum: 5fc7cb7731293af0ac186055ec511db4 (MD5) / Investigação de efeitos estéricos sobre o centro reacional na hidrólise ácida de O-alquil acetais do benzaldeído, através de técnicas espectroscópicas de ressonância magnética nuclear e cálculos computacionais para interpretação e correlação de dados cinéticos. Este estudo relaciona o aumento da reatividade e a mudança de mecanismo de reação com parâmetros estéricos e alterações sofridas no centro reacional devido ao incremento da carga estérica, que podem ser avaliadas por espectroscopia de ressonância magnética nuclear. Este trabalho mostra que a variação observada no deslocamento químico do carbono central, em função do substituinte, pode ser usada como parâmetro para medida de demanda estérica de outras reações químicas.
8

Utilização da imagem infravermelha normalizada para diagnóstico de doenças ocupacionais e correlação com eletromiografia de superfície e ressonância magnética

Filus, Rodrigo 12 December 2011 (has links)
Resumo: Nesta tese foram realizadas coletas de dados utilizando sistemas de captação superficial, representados aqui pela imagem infravermelha normalizada (termógrafo de superfície) e eletromiografia de superfície. Através destas técnicas foram acompanhadas as atividades desenvolvidas por trabalhadores de uma indústria de metalurgia em postos de trabalho que apresentam riscos biomecânicos como, por exemplo, sobrecarga muscular e posturas inadequadas. Dentre os grupos musculares trabalhados focou-se na sobrecarga muscular mais evidente no posto de trabalho; no caso a região do ombro. O objetivo principal é a verificação dos dados apresentados pelos métodos e a viabilização das técnicas de captação superficial para atribuir um risco biomecânico às respostas dos indivíduos estudados. Para validar a metodologia e o uso dessas técnicas em trabalhadores nas indústrias, um grupo de controle consistindo de trabalhadores sem lesões nos membros superiores foi analisado com ambas as técnicas e os resultados comparados com grupos que já tinham alguma lesão diagnosticada por um meio diagnóstico de imagem, i.e., a ressonância magnética. Avaliou-se também o uso de uma metodologia de normalização de leituras de temperatura na superfície corporal e uma metodologia de gradientes conjugados para diagnóstico de doenças, considerando a influência das condições ambientais e do metabolismo do indivíduo, provendo medições normalizadas para qualquer localização geográfica. Outro objetivo é a utilização de um grupo de temperatura adimensional apropriado como índice quantitativo para análise do campo de temperatura da superfície corporal. A pesquisa buscou validar experimentalmente a metodologia desenvolvida através da comparação direta entre as medições experimentais realizadas com a nova metodologia e com técnicas de diagnóstico e monitorização tradicionais na medicina (eletromiografia de superfície e ressonância magnética), para os casos patológicos selecionados. Para diagnóstico de doenças, com amostras apropriadas, a idéia foi definir faixas de normalidade quantitativas, como ilustração do potencial de aplicação universal do método desenvolvido. A amostra utilizada para o estudo consistiu de 13 indivíduos, dentre os quais 8 sadios e 5 patológicos. Os resultados obtidos com a metodologia dos gradientes conjugados para indivíduos diagnosticados foram comparados com médias normais de temperatura de indivíduos sadios, sendo capazes de detectar as anormalidades em 100% dos casos. A eletromiografia também apresentou como média de fadiga muscular valores maiores para os indivíduos diagnosticados. Com base nos resultados, conclui-se que a avaliação termográfica pode ser utilizada para estabelecer níveis de fadiga e também direcionar possíveis padrões diagnósticos de lesões.
9

Síntese, determinação da microestrutura e relação com as propriedades dos terpolímeros de etileno-propileno-1-penteno

Silva, Marco Antonio da January 2008 (has links)
Terpolímeros de etileno-propileno-1-penteno foram sintetizados empregando três sistemas catalíticos diferentes: rac-Et(Ind)2ZrCl2, Me2C(Cp)(Flu)ZrCl2 e o sistema suportado Cp2ZrCl2/MAO/SiO2 todos ativados com MAO. A razão de etileno e propileno foram variadas e duas concentrações de 1-penteno foram empregadas. Neste trabalho são apresentados os resultados qualitativos e quantitativos de caracterização destes terpolímeros através da técnica de ressonância magnética de carbono 13 (RMN de 13C) onde são apresentados os deslocamentos químicos observados e devidamente identificados, assim como a análise quantitativa das tríades, do comprimento médio das unidades consecutivas e das razões de reatividade. O efeito da adição de 1-penteno ao sistema etileno-propileno foi avaliado através dos resultados da atividade catalítica, incorporação de comonômero, propriedades térmicas, massa molar e propriedades mecânicas, para os três sistemas catalíticos em questão. Também foi avaliada a heterogeneidade de algumas amostras através do fracionamento por eluição com gradiente de temperatura (p-TREF). Para a atividade catalítica a ordem foi rac-EtInd2ZrCl2 > Cp2ZrCl2/MAO/SiO2 > i-Pr(Flu)(Cp)ZrCl2. O catalisador indenil foi o que proporcionou uma maior incorporação de termonômero, mostrando ser o catalisador mais eficiente para síntese de terpolímeros. Quanto ao catalisador suportado Cp2ZrCl2/MAO/SiO2, a incorporação de comonômero e termonômero foi bastante baixa e ele se mostrou inativo quando altas concentrações de propileno foram empregadas. O catalisador i-Pr(Flu)(Cp)ZrCl2 apresentou baixa atividade para a produção de copolímero etileno-propileno, e também não levou a formação de polímeros com concentração mais alta de propileno e terpolímeros. Com a análise de RMN de 13C foi possível caracterizar a estrutura do material, onde ficou demonstrado que ocorre uma competição entre propileno e o 1-penteno pela incorporação no polímero. À medida que aumenta a concentração de propileno no meio reacional, reduz-se a incorporação de 1-penteno nos terpolímeros, já para os copolímeros de propileno - 1-penteno, ocorre um aumento na incorporação de 1-penteno. A incorporação de propeno acarreta uma diminuição das unidades cristalizáveis de etileno, provocando um decréscimo na temperatura de fusão e massa molecular. Com concentrações mais altas de propileno ocorre um aumento das unidades cristalizáveis do propeno e, conseqüentemente, a cristalinidade aumenta. Análises dinâmico-mecânicas dos copolímeros e terpolímeros indicaram que o conteúdo de comonômero tem grande influência nas transições α e β. Para as propriedades mecânicas observou-se que a maior inserção de comonômero reduz a cristalinidade do material fazendo com que os terpolímeros apresentem um módulo menor do que os homopolímeros e também dos copolímeros, apresentando um comportamento elastomérico. / Series of ethylene (E), propylene (P) and 1-pentene (A) copolymers and terpolymers, differing in monomer composition ratio, were synthesized using (rac-Et(Ind)2ZrCl2/MAO), (Me2C(Cp)(Flu)ZrCl2/MAO and, (Cp2ZrCl2/MAO/SiO2/MAO) supported on silica impregnated with MAO as catalytic systems. The ratio of ethylene and propylene was varied from 0 to 100 and two concentrations of 1-pentene were employed. The catalytic activities at 25oC and atmospheric pressure were compared. A detailed study of ¹³C NMR chemical shifts, triad sequences distributions, monomer-average sequence lengths and reactivity ratios for the terpolymers is presented. The effect of the addition of 1-pentene to the ethylene-propylene was evaluated by the results of the catalytic activity, comonomer incorporation, thermal properties, mechanical properties and molecular weight. The heterogeneity of some samples was studied through the fractionation by elution with gradient of temperature (p-TREF). For the catalytic activity the order was rac-EtInd2ZrCl2 > Cp2ZrCl2/MAO/SiO2 >i-Pr(Flu)(Cp)ZrCl2. The indenyl catalyst presented the largest incorporation of termonomer, showing to be the most effective catalyst for synthesis of the terpolymers. The supported catalyst, Cp2ZrCl2/MAO/SiO2, presented an incorporation of termonomer quite low, and it was inactive when high concentrations of propylene were employed. The catalyst i-Pr(Flu)(Cp)ZrCl2 showed low activity in ethylene-propylene copolymerization at low propylene concentrations and it was inactive in terpolymerization. The 13C NMR analysis allowed to characterize the structure of the material., It was shown that there is a competition between propylene and 1-pentene for the incorporation into the polymer, when the propylene concentration increases there is a decrease of the 1-pentene concentration. The incorporation of propylene produces a reduction of the ethylene crystalline units, causing a decrease in the melting temperature and in the molecular weight. At higher concentrations of propylene there is an increase of the crystallizable units of propene and consequently an increase in the melting temperature. Dynamic-mechanical-thermal analyses of these copolymers and terpolymers showed that the comonomer content has great influence on the α- and β-transitions. For the mechanical properties it was observed that the increase in comonomer reduces the crystallinity of the material so that terpolymers have a lower module than homopolymers and copolymers and show an elastomeric behavior.
10

Comparação das sequências Double Inversion Recovery (DIR) - 3D e Fluid Attenuated Inversion recovery (FLAIR) - 3D em um aparelho de ressonância magnética de 3 Tesla na detecção de lesões corticais em pacientes com esclerose mútipla

Formighieri, Lucas January 2016 (has links)
Orientador : Prof. Dr. Dante Luiz Escuissato / Co-orientador : Prof. Dr. Arnolfo de Carvalho Neto / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Ciências da Saúde, Programa de Pós-Graduação em Medicina Interna. Defesa : Curitiba, 04/03/2016 / Inclui referências : f. 47-50 / Resumo: PANORMA E PROPÓSITO: A esclerose múltipla é uma doença inflamatória crônica autoimune que causa desmielinização e neurodegeneração no sistema nervoso central. Há crescente interesse ao dano causado por ela ao córtex. Estas lesões podem ser tão importantes quanto aquelas da substância branca, as quais são consideradas características da esclerose múltiplas. Novas técnicas de ressonância magnética estão sendo testadas para a avaliação das lesões corticais na esclerose múltipla. Uma destas técnicas é a Double Inversion Recovery (DIR), a qual é capas de simultaneamente suprimir o sinal da substância branca normal e do líquor, tornando as lesões corticais mais conspícuas. Estudos anteriores mostraram a superioridade da sequência DIR em comparação a sequências de ressonância magnéticas ditas convencionais em equipamentos de 1,5 Tesla, em aquisições 2D e 3D, e em equipamentos de 3 Tesla em aquisições 2D. Um estudo comparativo da sequência DIR em um equipamento de 3 Tesla com aquisição 3D não foi encontrado na literatura. MATERIAIS E MÉTODO: Neste estudo, 30 pacientes com a forma surto-remissão de esclerose múltipla foram examinados em um equipamento de ressonância magnética de 3 Tesla tendo sido adquiridas uma sequência 3D-DIR e outra 3D-FLAIR. Dois neurorradiologistas examinaram individualmente estas imagens procurando por lesões corticais, leucocorticais e justacorticais. Estas lesões foram então confirmadas e classificadas por consenso. Foram comparadas as habilidades das duas sequências de ressonância magnética de encontrar e classificar estas lesões. RESULTADOS: a sequência DIR encontrou 12% mais lesões do que a sequência FLAIR (p = 0,006) com baixa concordância entre os leitores. CONCLUSÃO: A superioridade da sequência DIR sobre a sequência FLAIR foi menor do que a esperada, mas a baixa concordância entre leitores já havia sido observada anteriormente. A metodologia de investigação de lesão por lesão utilizada neste estudo expôs a dificuldade de identificar e classificar estas lesões. / Abstract: BACKGROUND AND PURPOSE: Multiple sclerosis is a chronic inflammatory autoimmune disease that causes demyelination and neurodegeneration in the central nervous system. There is growing interest in the damage to the cortex caused by MS. These lesions are likely as important as those in the white matter, which is a hallmark trait of MS. New MRI techniques are being tested for the evaluation of cortical lesions in MS. One such technique is double inversion recovery (DIR), which is capable of simultaneously suppressing the signal from the normal white matter and cerebrospinal fluid, making cortical lesions more conspicuous. Previous studies have shown the superiority of DIR over conventional sequences at 1.5T (2D and 3D) and 3T (2D). To our knowledge, no study has been made to compare these two sequences in 3 T with a 3D acquisition. MATERIALS AND METHODS: In this study, 30 relapsing-remitting MS patients were imaged using 3D-DIR and 3D-FLAIR in a 3 T MRI equipment. Two neuroradiologists individually examined these images for cortical, leukocortical and juxtacortical lesions. The lesions were then confirmed and classified by consensus. The abilities of the two MRI sequences to find and classify cortical lesions were compared. RESULTS: The 3D-DIR sequence identified 12% more lesions than the 3D-FLAIR sequence (p = 0.006) with low agreement between readers. CONCLUSIONS: The superiority of 3D-DIR over 3D-FLAIR was less than expected, but the low agreement between readers has been previously observed. The lesion-by-lesion methodology used exposes the difficulties in identifying and classifying cortical lesions.

Page generated in 0.1415 seconds