• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 119
  • 71
  • 65
  • 44
  • 43
  • 32
  • 30
  • 25
  • 24
  • 24
  • 22
  • 21
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Efeitos da radiação x em um composito odontologico

Terra, Etienne Romanelli 21 February 2005 (has links)
Orientador: Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T04:17:51Z (GMT). No. of bitstreams: 1 Terra_EtienneRomanelli_M.pdf: 924097 bytes, checksum: 3d167bca45ac0474585a5d784fe9ec2a (MD5) Previous issue date: 2005 / Resumo: Como a maioria dos pacientes que se submetem à radioterapia na região de cabeça e pescoço possuem restaurações de compósitos na cavidade bucal, qualquer efeito interativo entre o feixe de radiação ionizante incidente e o material restaurador será clinicamente significativo, se as propriedades do material forem alteradas pela radiação. Desconhecendo-se os efeitos dos raios X, produzidos por um acelerador linear, no compósito odontológico FilteK Z250 (3M), foram realizados estudos para avaliar as possíveis alterações nas propriedades físicas, mecânicas e químicas deste compósito após a irradiação. Foram confeccionados 100 corpos-de-prova e mantidos armazenados durante todo o experimento a 37°C e 100% de umidade relativa do ar. O grupo 0 não irradiado foi composto por vinte corpos-de-prova, enquanto os demais corpos-de-prova foram aleatoriamente divididos em quatro grupos, conforme as doses de radiação X recebidas: 1, 2, 5 e 10Gy. Foram utilizados metade dos corpos-de-prova de cada um dos grupos para a análise de rugosidade de superfície e resistência à abrasão, e os demais, para a análise de dureza Knoop e espectrometria de Infravermelho com Transformações de Fourier. Os dados obtidos foram submetidos à análise de variância para medidas repetidas e teste de Tukey (a = 0,05). No período avaliado, houve um aumento estatisticamente significante na dureza Knoop superficial induzida pela irradiação de 10Gy de raios X, indicando uma polimerização adicional no compósito fotopolimerizado, porém, a resistência à abrasão e a rugosidade superficial do compósito Z250 não foram afetadas pelos raios X, quando o compósito foi irradiado até a dose de 10Gy. Os resultados obtidos por meio dos espectros de infravermelho, mostraram que em todas as doses avaliadas alguns grupos funcionais foram consumidos e novos grupos foram formados quando comparados com a amostra não irradiada. Assim, verificou-se que a irradiação (nas doses de 1, 2, 5 e 10Gy) durante o período avaliado não promoveu efeitos prejudiciais no compósito Z250, apesar das alterações no seu espectro químico / Abstract: Since most patients submitted to radiotherapy of the head and neck have composite restorations, any interactive effect between ionizing radiation and restorative material will be clinically significant if the material properties are altered by radiation. Due to the lack of knowledge on the effects of X rays produced by a linear accelerator on the dental composite Filtek Z250 (3M), this study was undertaken to evaluate the possible alterations in the physical, mechanical and chemical properties of this composite after irradiation. One hundred specimens were fabricated and stored at 37ºC and 100% relative humidity of air throughout the study. Group 0 was not irradiated and comprised twenty specimens, and the other specimens were randomly divided into four groups, according to the X-ray doses received: 1, 2, 5 and 10Gy. Half of the specimens of each group were used for analysis of surface roughness and abrasion resistance, and the others were submitted to the Knoop hardness test and Fourier Transform Infrared Spectrometry. Data were submitted to analysis of variance for repeated measurements and to the Tukey test (a = 0.05). In the study period, there was a statistically significant increase in the surface Knoop hardness induced by irradiation with 10Gy of X rays, indicating additional curing of the light-cured composite, yet the abrasion resistance and surface roughness of the composite Z250 were not affected by the X rays when the composite was irradiated with up to 10Gy. The results obtained by the infrared spectra demonstrated that, for all dosages evaluated, some functional groups are consumed and new groups are formed when compared to the non-irradiated sample. Thus, it was observed that irradiation (doses 1, 2, 5 and 10Gy) during the period evaluated did not yield any harmful effects on the composite Z250, despite the alterations in its chemical spectrum / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
112

Eficácia do ART e do tratamento convencional com resina composta sob isolamento absoluto em molares decíduos: estudo clínico randomizado e revisão sistemática com metanálise / Efficacy of ART and conventional treatment with composite resin under rubber dam isolation in primary molars: a randomized clinical trial and systematic review with meta-analysis

Ladewig, Nathalia de Miranda 14 March 2019 (has links)
O objetivo desta tese foi identificar, analisar e sintetizar evidências científicas quanto à eficácia do Tratamento Convencional (TC) e do Tratamento Restaurador Atraumático (ART) em molares decíduos considerando os parâmetros de longevidade, custo, aceitabilidade e desfechos reportados pelo paciente. Este volume apresenta um compilado de uma revisão sistemática e dois ensaios clínicos randomizados orientados pelas recomendações PRISMA, CONSORT-PRO e CHEERS. Realizamos uma revisão sistemática, cuja pesquisa bibliográfica buscou por desfechos reportados pelo paciente (PROs) em relação a tratamentos restauradores na dentição decídua em estudos prospectivos indexados no PubMed, Scopus e OpenGrey até fevereiro de 2018. Meta-análise de Comparação de Tratamento Misto foi realizada considerando os resultados dos estudos revisados. Devido à incompatibilidade de dados, apenas dor, ansiedade e a qualidade de vida relacionada à saúde bucal (QVRSB) foram analisados estatisticamente. Adicionalmente, delineamos um ensaio clínico de não inferioridade randomizado por cluster cujo desfecho primário foi a longevidade do TC e do ART em cavidadades oclusais e oclusoproximais de molares decíduos após 24 meses de acompanhamento. Como desfechos secundários, foram avaliados a aceitabilidade, representada pelo desconforto auto relatado e cooperação dos participantes, e a custo-eficácia. Crianças entre 3 e 6 anos apresentando pelo menos uma cavidade oclusal ou oclusoproximal em molares decíduos foram randomizadas entre os grupos convencional (TC) com resina composta sob isolamento absoluto após anestesia local ou o ART. Em ambos os grupos foi realizada remoção parcial de tecido cariado. O estudo foi desenvolvido em um trailer odontológico localizado no interior de uma escola municipal de Barueri/SP. Imediatamente após cada sessão restauradora, foi mensurado o desconforto auto relatado pelo participante e o comportamento pelo operador através da Escala Facial de Wong-Baker e escala de 5 pontos, respectivamente. As restaurações oclusais e oclusoproximais foram avaliadas após 6, 12, 18 e 24 meses segundo o critério de Frencken et al. 1998 e de Roeleveld et al. 2006. Os custos profissional e do procedimento, subdividido em custos variável e do material de consumo, foram considerados para estimar o custo incremental dos tratamentos. Regressão de Poisson em análise de multinível, Regressão de Cox com fragilidade compartilhada e regressão de Bootstrap foram utilizadas para testar o desconforto e cooperação, a sobrevida e o custo entre os tratamentos e outras variáveis independentes. O nível de significância foi ajustado em 5%. Tratamentos restauradores que utilizam agentes quimicomecânicos ou apenas instrumentos manuais para remoção de tecido cariado, como o ART, resultaram em menores índices de ansiedade e menor tendência em provocar dor em crianças do que tratamentos que utilizam instrumentos rotatórios e/ou anestesia. A QVRSB não foi influenciada pelos tratamentos restauradores nem diferiu entre os grupos. Por outro lado, o TC e o ART apresentaram baixa taxa de desconforto e alto índice de cooperação sem diferença estatisticamente significante entre eles. Ambos os tratamentos apresentaram sobrevida semelhante nas cavidades oclusais após 24 meses de acompanhamento, porém o custo do ART foi menor, demonstrando ser a opção mais custo-eficaz. Em relação às restaurações oclusoproximais, apesar do desempenho do TC ser superior ao ART, ele apresentou maior custo. Pode-se concluir que ansiedade e dor estão diretamente relacionados com tratamentos restauradores mais invasivos. Por outro lado, o TC e o ART apresentaram desconforto, cooperação e custo-eficácia semelhantes no tratamento de molares decíduos. Palavras-chave: Restauração dentária permanente. Dente decíduo. Longevidade. Custos e análises de custo. Medidas de resultados relatados pelo paciente. Ensaio clínico. Revisão. Odontopediatria. / The aim of this thesis was to identify, analyze and synthesize scientific evidences regarding the efficacy of conventional treatment (CT) and Atraumatic Restorative Treatment (ART) in primary molars considering the parameters of longevity, cost, acceptability and patient reported outcomes. This volume presents a compilation of a systematic review and two randomized clinical trials guided by the PRISMA, CONSORT-PRO and CHEERS recommendations. We performed a systematic review whose literature search included outcomes reported by the pediatric patient (PROs) related to restorative treatments in the primary dentition in prospective studies indexed in PubMed, Scopus and OpenGrey until February 2018. Mixed Treatment Comparison analysis was performed considering the results of the reviewed studies. Due to data incompatibility, only pain, anxiety and oral health related to quality of life (OHRQoL) were analyzed statistically. Additionally, we designed a cluster randomized non-inferiority clinical trial whose primary outcome was the longevity of occlusal and occlusoproximal ART and TC restorations in primary molars after 24 months of follow-up. As secondary outcomes, acceptability, represented by self-reported discomfort and participant cooperation, and cost-efficacy were assessed. Children between 3 and 6 years old presenting at least one occlusal or occlusoproximal cavity in primary molars were randomized between the conventional group (TC) with composite resin under rubber dam isolation after local anesthesia or ART. Partial removal of carious tissue was performed in both groups. The study was carried out in a dental trailer located inside a municipal school in Barueri/SP. Immediately after each restorative session, self-reported discomfort and participant cooperation were measure through the Wong-Baker Facial Scale and a 5-point scale, respectively. The occlusal and occlusoproximal restorations were evaluated after 6, 12, 18 and 24 months according to the criteria of Frencken et al. 1998 and Roeleveld et al. 2006. The professional and procedural costs, subdivided into variable and material of consumption\' costs, were considered to estimate treatments\' incremental cost. Poisson regression in multilevel analysis, Cox regression with shared fragility and Bootstrap regression were used to test discomfort and cooperation, survival and cost between treatments and among others independent variables. The level of significance was set at 5%. Restorative treatments using chemomechanical agents or only manual instruments, such as ART, were related to lower anxiety rates and less tendency to provoke pain in children compared to treatments using rotary instruments and/or anesthesia. OHRQoL was not influenced by restorative treatments nor differed between groups. On the other hand, CT and ART presented low rate of discomfort and a high cooperation with no statistically significant difference between them. Both treatments presented similar survival rates in occlusal restorations after 24 months of follow-up, but the ART cost was lower, proving to be the most cost-effective option. Regarding occlusoproximal restorations, although CT performance was superior to ART, it presented a higher cost. It can be concluded that anxiety and pain are directly related to more invasive restorative treatments. Differently, CT and ART have similar discomfort, cooperation and cost-efficacy in the treatment of primary molars.
113

Estudo de parâmetros eletrocardiográficos e de pressão arterial durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em portadores de doença arterial coronária / Investigation of electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia with and without vasoconstrictor in coronary artery disease patients

Neves, Ricardo Simões 12 December 2006 (has links)
Estudamos 62 pacientes, que com teste ergométrico positivo, manifestaram angina estável e estavam sob controle farmacológico. Todos apresentavam cinecoronariografia mostrando obstrução >70% em pelo menos uma das principais artérias coronárias. Objetivamos avaliar parâmetros eletrocardiográficos e de pressão arterial, durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em presença de doença arterial coronária. As idades variaram de 39 a 80, média de 58,7±8,8 anos, sendo 51 (82,3%) homens. Trinta pacientes foram randomizados para receber anestesia local com solução de lidocaína a 2% com adrenalina 1:100.000 e os demais para lidocaína a 2% sem vasoconstritor. Todos os pacientes foram submetidos à monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica por 24 horas, iniciados 2 horas antes do procedimento odontológico. Consideramos 3 períodos de registro: (1) basal - os 60 minutos que antecederam ao procedimento odontológico; (2) procedimento - desde o início da anestesia até o final do procedimento odontológico restaurador; (3) subseqüente completar das 24 horas. A análise de variância com medidas repetidas mostrou que houve elevação significativa da pressão arterial sistólica e diastólica do período basal para o procedimento nos dois grupos estudados (aproximadamente 14mmHg e 5 a 7mmHg) respectivamente, quando analisados separadamente e quando confrontados não apresentaram diferença de comportamento entre si. A freqüência cardíaca não se alterou nos dois grupos estudados. Depressão do segmento ST >1mm ocorreu em 10 (17,9%) pacientes; todos os eventos ocorreram no mínimo 2 horas após o término do procedimento odontológico. Extra - sístoles supra-ventriculares e/ou extra-sístoles ventriculares em número maior do que 10/hora estiveram presentes em 17 (30,4%) pacientes durante as 24 horas e durante o período do procedimento em 7 (12,5%), sendo 4 (13,8%) do grupo que recebeu anestesia sem adrenalina e 3 (11,1%) do grupo que recebeu anestesia com adrenalina e o teste Exato de Fisher não mostrou diferença entre os grupos. Concluímos que não houve diferença em relação ao comportamento de pressão arterial, freqüência cardíaca, evidência de isquemia e arritmias entre os grupos. O uso associado de vasoconstritor mostrou-se, portanto, seguro dentro dos limites do estudo. / We enrolled 62 patients with positive exercise stress test who presented with stable angina and were receiving drug therapy. All had a coronary angiography screening showing >70% obstruction in at least one of the main coronary arteries. The study aimed to compare electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia, both with and without vasoconstrictor, in the presence of coronary artery disease. Ages ranged from 39 to 80, (mean ± SD) 58.7±8.8 years, 51 (82.3%) of them were male. Thirty patients were randomly assigned to receive 2% lidocaine local anesthesia with 1:100,000 epinephrine, the others receiving 2% lidocaine without vasoconstrictor. All the patients underwent ambulatory blood pressure and 24-hour Holter monitoring, beginning two hours ahead of the dental procedure. Recording were made during (1) baseline - 60-minute period before dental procedure began; (2) procedure - from beginning of anesthesia until the end of the procedure; and (3) subsequent 24-hour period. Analysis of variance with repeat measures showed significant diastolic and systolic blood pressure increases from baseline to the period of the procedure, in the two study groups (approximately 14 mm Hg, and 5 to 7 mm Hg, respectively); both in a separate analysis and in a comparative analysis no significant difference between them could be confirmed. Heart rate did not change in neither of the two groups. ST-segment >1 mm depression was detected in 10 (17.9%) patients; all these events occurred at least two hours after the end of the dentistry procedure. Premature supraventricular systoles and/or premature ventricular systoles in a greater number than 10/hour were seen in 17 (30.4%) patients in the 24-hours period after the procedure; during the procedure they occurred in 7 (12.5%) patients, of whom 4 (13.8%) were in the group without, and 3 (11.1%) in the group with vasoconstrictor. The Fisher\'s exact test revealed no difference between the groups. We concluded that there was no difference of blood pressure, heart rate, evidence of ischemia or arrhythmia episodes between the groups. Thus, the associated use of vasoconstrictor proved to be safe within the limits of this study
114

Efeito da aplicação de ondas de ultrassom sobre cimentos de ionômero de vidro e dentina subjacente

Coldebella, Cármen Regina [UNESP] 07 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-07Bitstream added on 2014-06-13T20:21:49Z : No. of bitstreams: 1 coldebella_cr_dr_arafo.pdf: 1165027 bytes, checksum: 68372d3e55cbf9fcc5b26e1b2514cf7c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição: O objetivo deste trabalho, dividido em três estudos, foi investigar o efeito após a aplicação de ondas de ultrassom sobre cimentos de ionômero de vidro (CIV) (1) a dureza da dentina subjacente, hígida e afetada por cárie; (2) a resistência de união à dentina hígida e afetada por cárie (3) e à rugosidade do material após ensaio de escovação. Materiais e métodos: Nos três estudos foram utilizados os CIV Vitremer (VT) e Ketac Molar Easymix (KM). Para o estudo 1 foram realizados preparos cavitários (3 mm de largura, 5 mm de comprimento e 2 mm de profundidade) na face vestibular de 80 incisivos bovinos. Foi realizada a indução de lesão de cárie artificial pelo método microbiológico (n=40). Os dentes foram distribuídos em 8 grupos (n=10), segundo o substrato (hígido ou afetado por cárie), material utilizado (VT ou KM) e o tratamento recebido (com ou sem a aplicação de ondas de ultrassom). A aplicação de ondas de ultrassom foi realizada por 30 segundos. Após 30 dias de armazenagem em água os dentes foram seccionados e as leituras de dureza Knoop realizadas na dentina subjacente ao material até 200 μm de distância da interface dentina/CIV. No segundo estudo foram confeccionados 20 blocos de dentina bovina para cada material, sendo que 10 deles foram submetidos ao processo de indução de lesão de cárie artificial e subsequente remoção da dentina contaminada. Em cada bloco foram confeccionados dois corpos de prova com 1,5 cm de altura e 3 cm de diâmetro, sendo o primeiro com e o segundo sem a aplicação de 30 segundos de ondas de ultrassom. Após 24 horas, os corpos de prova foram submetidos ao ensaio mecânico de cisalhamento. No terceiro trabalho 32 espécimes de cada material, VT e KM, foram confeccionados em matriz de dente bovino, sendo que a metade recebeu ondas... / Aim: This work was divided into three studies. The objective was to investigate the effect of ultrasound application on glass ionomer cement (GIC), analyzing underlying dentin hardness, bond strength to noncarious dentin and cariesaffected dentin and the material roughness after toothbrushing test. Materials and methods: GIC Vitremer (VT) and Easymix Ketac Molar (KM) were used in these studies. In the first study, cavities (3 mm wide, 5 mm in length and 2 mm deep) were performed on the buccal surface of eighty bovine incisors. Microbiological method was used to induce artificial caries lesions (n = 40). The teeth were divided into 8 groups (n = 10), according the substrate (noncarious dentin or caries-affected dentin), the material used (VT or KM) and the treatment received (with or without ultrasound application). The ultrasound application was performed for 30 seconds, and teeth stored in water for 30 days. After that, the specimens were sectioned and transversal hardness evaluation was performed in the underlying dentin material up to depth of 200 μm. In the second study, 20 dentin blocks were used for each material. Ten of them were artificially decayed and performed subsequent removal of infected dentin. In each block, two specimens (1.5 cm high and 3 cm diameter) were performed, the first with and the second without ultrasound application. After 24 hours the specimens were shear bonding tested. For the third study 32 specimens of each material, VT and KM, were prepared using a bovine tooth matrix. Half of them received a 30 s ultrasound application during its initial setting. The surface roughness, before and after toothbrushing test, was evaluated at 24 hours (n = 16) and 30 days (n = 16). Data were analyzed by ANOVA and Tukey tests. For all the studies, the statistical tests were considered at the present level... (Complete abstract click electronic access below)
115

Efeito da infiltração de sílica pelo método sol-gel na resistência à flexão de bicamadas de porcelana e Y-TZP / Effect of silica infiltration by sol-gel method on the flexural strength of porcelain and Y-TZP bilayers

Reis, Ana Flávia Nunes [UNESP] 15 December 2015 (has links)
Submitted by ANA FLÁVIA NUNES E REIS null (dra-anaflavia@uol.com.br) on 2016-01-26T19:16:31Z No. of bitstreams: 1 merged (4).pdf: 4937949 bytes, checksum: c052666784bd930ac4748e41040c73bd (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-01-28T13:31:20Z (GMT) No. of bitstreams: 1 reis_afn_me_sjc.pdf: 4937949 bytes, checksum: c052666784bd930ac4748e41040c73bd (MD5) / Made available in DSpace on 2016-01-28T13:31:20Z (GMT). No. of bitstreams: 1 reis_afn_me_sjc.pdf: 4937949 bytes, checksum: c052666784bd930ac4748e41040c73bd (MD5) Previous issue date: 2015-12-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi infiltrar sílica em uma cerâmica Y-TZP, avaliar seu efeito na resistência à flexão Biaxial, e na união com a porcelana feldspática. Para a análise da resistência à flexão foram confeccionados 180 discos de zircônia, 120 de 0,5mm e 60 com 1,2mm discos (14 mm de diâmetro). 90 discos foram infiltrados com sílica pelo método sol-gel em temperatura ambiente (n = 30). A espessura do disco foi de 1,2 mm para os espécimes controle (espécime sem porcelana, n = 30). O recobrimento por porcelana feldspática foi de duas espessuras (0,5mm e 1 mm) sobre a zircônia que tinha 0,5 mm. Os espécimes com porcelana foram polidos com lixas de carbeto de silício (SiC) de granulação # 400, 600, 800 e 1200. Obtivemos 6 grupos: dois monolíticos (ZR- Zircônia Monolítica sem infiltração e ZRI- Zircônia Monolítica Infiltrada) (controle) e quatro estratificados: ZRF 1,0 (0,5mm Zircônia coberta com 0,5 mm porcelana), ZRIF 1,0 (0,5 mm Zircônia infiltrada coberta com 0,5 mm de porcelana), ZRF 1,5 (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana) ZRIF 1,5- Zircônia infiltrada (0,5 mm Zircônia infiltrada coberta com 1,0 mm de porcelana). Após o ensaio de flexão biaxial em meio aquoso, foram determinados o módulo de Weibull (m) e resistência característica (σθ). Os fragmentos foram analisados em EDS, MEV, DRX e FTIR. A Dureza (H) e tenacidade a fratura foram analisadas pela nanoindentação, já o módulo elástico (E) por duas técnicas, nanoindentação e por impulso, e para avaliar a adesão entre a zircônia e a porcelana foi aplicado o Teste de Scratch. Foram modeladas 7 condições experimentais e analisados pelo método por elementos finitos. A zircônia monolítica infiltrada mostrou uma estrutura com grãos arredondados envoltos em uma matriz de sílica, e a presença de zircônia cúbica e tetragonal. O DRX revelou a formação de ZrSiO4 nos grupos infiltrados. Os grupos monolíticos apresentaram módulos de Weibull superiores aos dos grupos com porcelana. Com a análise (AEF) não houve diferença entre os grupos com a mesma espessura, já para o grupo recoberto com 0,5 mm de porcelana, os valores de tração e compressão foram maiores. A cerâmica infiltrada apresentou microestrutura diferente, e a adesão da porcelana à zircônia não-infiltrada foi superior à da zircônia infiltrada. / The objective was to infiltrate silica in a Y- TZP ceramics, evaluate its effect on resistance biaxial strenght, and the union with feldspathic porcelain. For the analysis of flexural strength were prepared zirconia discs 180, 120 and 60 of 0.5 mm to 1.2 mm disks (14 mm diameter). 90 discs were infiltrated with silica by the sol-gel method at room temperature (n = 30). The thickness of the disk was 1.2 mm for the samples control (no porcelain specimen, n = 30). The coating was feldspathic porcelain by two thicknesses (0.5 mm and 1 mm) of zirconia, which had 0.5 mm. Specimens with porcelain were polished with sandpaper silicon carbide (SiC) granulation # 400, 600, 800 and 1200. We obtained six groups: two monolithic (Zr-Zirconia Monolithic without infiltration and ZRI- Zirconia monolithic Infiltrated) (control) and four laminated ZRF 1.0 (0.5 mm zirconia covered with 0.5 mm porcelain), ZRIF 1.0 (0.5 mm infiltrated zirconia covered with 0.5 mm of porcelain), ZRF 1.5 (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain) ZRIF 1,5-infiltrated Zirconia (0.5 mm infiltrated zirconia covered with 1.0 mm of porcelain). After the biaxial bending test in an aqueous medium were determined Weibull modulus (m) and the characteristic strength (σθ). The fragments were analyzed by EDS, SEM, XRD and FTIR. The hardness (H) and fracture toughness were analyzed by nanoindentation, since the elastic modulus (E) by two techniques, nanoindentation and on impulse, and to evaluate the adhesion between the zirconia and porcelain was applied Scratch Test. 7 experimental conditions were modeled and analyzed by the finite element method. The infiltrated zirconia showed a monolithic structure with rounded grain wrapped in a silica matrix, and the presence of cubic and tetragonal zirconia. The XRD showed the formation of ZrSiO4 infiltrates in groups. The monolithic modules Weibull groups showed superior to porcelain groups. With the analysis (FEA) there was no difference between the groups with the same thickness, for now the group covered with 0.5 mm of porcelain, the tensile and compressive values were higher. The infiltrated ceramic showed different microstructure, and the accession of porcelain to non- infiltrated zirconia was higher than the infiltrated zirconia.
116

Efeito da técnica restauradora, do tipo de preparo e do envelhecimento de restaurações de resina composta sobre a resistência à fratura dental, resistência adesiva e vedamento marginal / Restorative technique, kind of prepair and aging effects on composite resin restorations fracture strength, restoration retention and marginal adaptation

Souza, Fábio Herrmann Coelho de 23 June 2006 (has links)
Made available in DSpace on 2014-08-20T14:30:20Z (GMT). No. of bitstreams: 1 Tese - Fabio Herrmann.pdf: 2352205 bytes, checksum: a6bcc0f4e7708f23fde2f31a66c02b83 (MD5) Previous issue date: 2006-06-23 / The aim of this study was to evaluate, in vitro, the effect of composite resin restoration techniques, bevel and storage time on the fracture strength, restoration retention and gap formation. For the fracture strength test, standard MOD cavities were prepared in 100 upper premolars, which were divided in two storage times (24 hours and 6 months with 1000 thermocycles), and in each group, sub-groups were randomly formed as follow: group 1 direct composite resin restoration(Filtek Z250 and Adper Single Bond 3M/ESPE) without bevel (butt joint); group 2 beveled direct composite resin restoration; group 3 indirect composite resin inlay (Z250 and Rely X ARC 3M/ESPE) without bevel(butt joint); group 4 beveled indirect composite resin inlay; group 5 sound teeth; group 6 teeth with MOD preparations (no restorations). For the retention test, the incisal edge of 90 lower incisors was sectioned, and divided in the same restorative groups as described above (except group 6). To evaluate gap presence or absence, proximal box cavities were prepared in 24 human third molars, which were restored with direct or indirect composite restorations, with or without bevel, similar to above described and examined under SEM evaluation. Data was statistically analysed by A NOVA, Tukey and t-student tests for fracture strength and retention tests, and Fisher s exact test for gap formation (=0,05). At the 24 hours, beveled restorations exhibited higher fracture strength values than non beveled restorations and most of the tested groups showed resistance similar or superior than sound teeth. After 6 months, the best results were obtained for beveled inlays and the worst values were observed for butt joint direct restorations. In the retention test,beveled restorations had superior performances than non-beveled restorations, in both periods of time. For both tests, a 6-month storage time and thermal cycling produced significant properties decrease in groups 1, 2 and 4 showed. Under SEM examination, no difference was observed among groups after 24 hours. However,after 6 months, beveled restotations remained without gap formation and they had better performance than butt joint restorations. Pearson correlation test showed positive correlation between fracture strength and retention tests. Within the limitations of the study, it was concluded that aging impaired adhesive properties, bevel improved the performance in all tests and generally indirect restorations were not superior to direct restorations. / O objetivo do presente trabalho foi avaliar in vitro o efeito da técnica restauradora, da confecção de bisel e do tempo de armazenamento de restaurações de resina composta sobre a resistência à fratura dental, resistência à fratura de restaurações (resistência adesiva) e formação de fenda marginal. Para o teste de resistência à fratura dental, foram utilizados 100 pré-molares superiores, submetidos a preparos cavitários MOD, divididos em 2 tempos de armazenamento (24 horas e 6 meses com termociclagem 1000 ciclos), subdivididos nos seguintes grupos: grupo 1 restaurados com resina composta direta (Filtek Z250 e Adper Single Bond 3M/ESPE) sem bisel; grupo 2 resina composta direta com bisel; grupo 3 resina composta semi-direta (Z250 e Rely X ARC 3M/ESPE) sem bisel; grupo 4 resina composta semi-direta com bisel; grupo 5 dentes hígidos; e grupo 6 dentes apenas preparados (n=10). Para o teste de resistência à fratura de restaurações, foram utilizados 90 incisivos inferiores, que receberam desgaste do bordo incisal e foram divididos nos mesmos grupos citados acima (exceto o grupo 6). Para a avaliação de presença ou ausência de fenda marginal,foram empregados 24 terceiros molares, que receberam preparos proximais, divididos nos mesmos grupos acima (exceto os grupos 5 e 6). Os dados foram submetidos à análise estatística (=0,05) através dos testes ANOVA, Tukey e t-student para resistência à fratura dental e resistência à fratura de restaurações e teste exato de Fisher para formação de fenda marginal. Os resultados mostraram que, para resistência à fratura dental, no tempo de 24 horas, as restaurações com bisel foram superiores às demais, enquanto as sem bisel não diferiram dos dentes hígidos. Após 6 meses, as restaurações semi-diretas com bisel foram superiores às demais, não diferindo das semi-diretas sem bisel; as restaurações diretas sem bisel foram inferiores às demais. Para resistência à fratura de restaurações, as restaurações com bisel foram superiores às demais para ambos os tempos de armazenamento, e não diferiram dos dentes hígidos em 24 horas. Para os 2 testes citados, os grupos 1, 2 e 4 apresentaram redução significativa do seu desempenho após 6 meses de armazenamento e termociclagem. A avaliação de fenda em esmalte mostrou que em 24 horas não houve diferença entre os grupos. Após 6 meses, as restaurações com bisel continuaram livres de fenda, enquanto as sem bisel apresentaram fenda na maioria dos espécimes. A análise de correlação de Pearson mostrou resultado significativamente positivo para os 2 testes de resistência. Concluiu-se que o tempo de armazenamento e termociclagem foram fatores significativos na redução da performance adesiva; a realização de bisel influenciou de forma positiva na melhora do desempenho das restaurações em todos os testes empregados; as restaurações semi-diretas de resina composta, de modo geral, não foram superiores às diretas.
117

Estudo de parâmetros eletrocardiográficos e de pressão arterial durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em portadores de doença arterial coronária / Investigation of electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia with and without vasoconstrictor in coronary artery disease patients

Ricardo Simões Neves 12 December 2006 (has links)
Estudamos 62 pacientes, que com teste ergométrico positivo, manifestaram angina estável e estavam sob controle farmacológico. Todos apresentavam cinecoronariografia mostrando obstrução >70% em pelo menos uma das principais artérias coronárias. Objetivamos avaliar parâmetros eletrocardiográficos e de pressão arterial, durante procedimento odontológico restaurador sob anestesia local com e sem vasoconstritor em presença de doença arterial coronária. As idades variaram de 39 a 80, média de 58,7±8,8 anos, sendo 51 (82,3%) homens. Trinta pacientes foram randomizados para receber anestesia local com solução de lidocaína a 2% com adrenalina 1:100.000 e os demais para lidocaína a 2% sem vasoconstritor. Todos os pacientes foram submetidos à monitorização ambulatorial da pressão arterial (MAPA) e eletrocardiografia dinâmica por 24 horas, iniciados 2 horas antes do procedimento odontológico. Consideramos 3 períodos de registro: (1) basal - os 60 minutos que antecederam ao procedimento odontológico; (2) procedimento - desde o início da anestesia até o final do procedimento odontológico restaurador; (3) subseqüente completar das 24 horas. A análise de variância com medidas repetidas mostrou que houve elevação significativa da pressão arterial sistólica e diastólica do período basal para o procedimento nos dois grupos estudados (aproximadamente 14mmHg e 5 a 7mmHg) respectivamente, quando analisados separadamente e quando confrontados não apresentaram diferença de comportamento entre si. A freqüência cardíaca não se alterou nos dois grupos estudados. Depressão do segmento ST >1mm ocorreu em 10 (17,9%) pacientes; todos os eventos ocorreram no mínimo 2 horas após o término do procedimento odontológico. Extra - sístoles supra-ventriculares e/ou extra-sístoles ventriculares em número maior do que 10/hora estiveram presentes em 17 (30,4%) pacientes durante as 24 horas e durante o período do procedimento em 7 (12,5%), sendo 4 (13,8%) do grupo que recebeu anestesia sem adrenalina e 3 (11,1%) do grupo que recebeu anestesia com adrenalina e o teste Exato de Fisher não mostrou diferença entre os grupos. Concluímos que não houve diferença em relação ao comportamento de pressão arterial, freqüência cardíaca, evidência de isquemia e arritmias entre os grupos. O uso associado de vasoconstritor mostrou-se, portanto, seguro dentro dos limites do estudo. / We enrolled 62 patients with positive exercise stress test who presented with stable angina and were receiving drug therapy. All had a coronary angiography screening showing >70% obstruction in at least one of the main coronary arteries. The study aimed to compare electrocardiographic and blood pressure parameters during restorative dentistry procedure under local anesthesia, both with and without vasoconstrictor, in the presence of coronary artery disease. Ages ranged from 39 to 80, (mean ± SD) 58.7±8.8 years, 51 (82.3%) of them were male. Thirty patients were randomly assigned to receive 2% lidocaine local anesthesia with 1:100,000 epinephrine, the others receiving 2% lidocaine without vasoconstrictor. All the patients underwent ambulatory blood pressure and 24-hour Holter monitoring, beginning two hours ahead of the dental procedure. Recording were made during (1) baseline - 60-minute period before dental procedure began; (2) procedure - from beginning of anesthesia until the end of the procedure; and (3) subsequent 24-hour period. Analysis of variance with repeat measures showed significant diastolic and systolic blood pressure increases from baseline to the period of the procedure, in the two study groups (approximately 14 mm Hg, and 5 to 7 mm Hg, respectively); both in a separate analysis and in a comparative analysis no significant difference between them could be confirmed. Heart rate did not change in neither of the two groups. ST-segment >1 mm depression was detected in 10 (17.9%) patients; all these events occurred at least two hours after the end of the dentistry procedure. Premature supraventricular systoles and/or premature ventricular systoles in a greater number than 10/hour were seen in 17 (30.4%) patients in the 24-hours period after the procedure; during the procedure they occurred in 7 (12.5%) patients, of whom 4 (13.8%) were in the group without, and 3 (11.1%) in the group with vasoconstrictor. The Fisher\'s exact test revealed no difference between the groups. We concluded that there was no difference of blood pressure, heart rate, evidence of ischemia or arrhythmia episodes between the groups. Thus, the associated use of vasoconstrictor proved to be safe within the limits of this study
118

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Neves, Itamara Lucia Itagiba 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.
119

Monitorização materno-fetal da portadora de doença valvar reumática durante procedimento odontológico sob anestesia local / Maternal-fetal monitoring of patients with rheumatic heart disease during dental procedure under local anesthesia

Itamara Lucia Itagiba Neves 15 February 2007 (has links)
Modificações na fisiologia do organismo da mulher ocorrem durante a gravidez em conseqüência às alterações hormonais, anatômicas e metabólicas. No sistema circulatório a modificação mais significativa é o aumento do débito cardíaco a partir do primeiro trimestre da gestação. Mulheres portadoras de cardiopatias podem apresentar graves complicações durante o período gestacional devido à inapropriada adaptação à sobrecarga hemodinâmica, mesmo em pacientes consideradas em capacidade funcional favorável, no início da gestação. A literatura carece de estudos dos efeitos dos anestésicos locais com ou sem vasoconstritor utilizados nos procedimentos odontológicos, sobre os parâmetros cardiovasculares de mulheres gestantes portadoras de valvopatias e seus conceptos. A escassez científica fez deste tema nosso objetivo de estudo: avaliar e analisar parâmetros da cardiotocografia, como freqüência cardíaca, motilidade fetal e contrações uterinas e de pressão arterial e eletrocardiográficos da gestante portadora de doença valvar reumática quando submetida à anestesia local com lidocaína, com e sem vasoconstritor, durante procedimento odontológico restaurador. Para tanto, a monitorização ambulatorial da pressão arterial (MAPA) e a eletrocardiografia ambulatorial (Holter) materna, ambas obtidas durante 24 horas e a cardiotografia (CTG) de 31 portadoras de cardiopatia reumática entre a 28ª e 37ª semana de gestação, nos períodos: (1) basal - 60 minutos antes do procedimento para MAPA e Holter e 20 minutos para CTG; (2) procedimento - 56+15,5minutos (média+desvio padrão); (3) pós-procedimento - 20 minutos; e (4) média das 24 horas para freqüência cardíaca e extra-sístoles e média da vigília e do sono para pressão arterial, permitiu a análise da variação desses parâmetros, utilizando-se lidocaína 2% sem vasoconstritor e lidocaína 2% com epinefrina 1:100.000, compondo-as em dois grupos. Demonstrou-se redução significativa nos valores de freqüência cardíaca materna durante o procedimento somente quando comparado aos demais períodos (p<0,001). Quando comparados os dois grupos, não houve diferença (p>0,05). Houve ocorrência de arritmia cardíaca em 9 (29,0%) pacientes, sendo 7 (41,8%) do grupo que recebeu anestesia com adrenalina. A pressão arterial materna não apresentou diferença quando comparamos os períodos ou os grupos (p>0,05). O mesmo ocorreu (p>0,05) nas análises comparativas dos parâmetros fetais obtidos por meio da CTG - número de contrações, nível e variabilidade da linha de base, número de acelerações da freqüência cardíaca fetal e padrão de reatividade fetal. Concluiu-se que o uso da lidocaína 2% associado à adrenalina mostrou-se seguro em procedimento odontológico durante a gestação de mulheres com cardiopatia valvar reumática. / During pregnancy, the organic systems of a woman are subjected to physiological modifications consequential to hormonal, anatomic and metabolical alterations. The most significant modification in the circulatory system is an increased cardiac output from the first three months of gestation. Women with heart disease may present with severe complications during the gestational period, because of inappropriate adaptation of her body to this hemodynamic overload, even those patients who are thought to have an appropriate functional capacity during early pregnancy. There are scant studies in the literature on the effects of local anesthetics, with and without vasoconstrictor, used in dental procedures on the cardiovascular variables of pregnant women with valvar disease, as well as on their concepti. Driven by this shortage, we decided to have this subject studied, by assessing and analyzing cardiotachographic parameters, such as heart rate, fetal motility and uterine contractions, in addition to blood pressure and electrocardiographic variables, in pregnant women with rheumatic valvar disease who undergo local anesthesia with lidocaine, with and without vasoconstrictor, during restorative dental procedure. For this, 31 rheumatic heart disease patients who were in their 28th to 37th week of gestation, had 24-hour ambulatory monitoring of their blood pressure (BP) and Holter electrocardiography (Holter-ECG), and cardiotocography (CTG), performed during: (1) baseline - 60 minutes before the procedure for BP and Holter- ECG monitoring, and 20 minutes before the procedure for CTG; (2) procedure - 56±15.5 minutes (mean±SD); (3) post-procedure - 20 minutes; and (4) mean 24-hour heart rate and extrasystoles measurement, and mean wake and sleeping periods BP monitoring. Variation of the above variables was analyzed in two groups, one with infusion of a 2% solution of lidocaine with vasoconstrictor, and the other with infusion of a 2% solution of lidocaine with epinephrine 1:100.000. The maternal heart rate values obtained during the procedure showed a significant reduction only in comparison with the other time periods (P<0.001). The comparison of the two groups did not reveal any significant difference (P>0.05). Cardiac arrhythmia was detected in 9 (29.0%) patients, 7 of them (41.8%) from the group who received anesthetics with epinephrine. Maternal blood pressure did not show any significant difference neither between time periods, nor between groups (P>0.05). The same occurred in the comparative analysis of the fetal parameters obtained during CTG -number of contractions, level and variability from baseline, number of fetal heart rate accelerations and fetal reactivity pattern. Our conclusion was that the use of 2% solution of lidocaine in association with epinephrine proved safe during dental procedure in pregnant women with rheumatic valvar cardiopathy.

Page generated in 0.077 seconds