• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 119
  • 71
  • 65
  • 44
  • 43
  • 32
  • 30
  • 25
  • 24
  • 24
  • 22
  • 21
  • 20
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Incidência de fraturas em próteses fixas: estudo retrospectivo. Análise da sobrevivência de próteses metalocerâmicas após um período mínimo de quatro anos em função / Fractures Incidence on fixed prostheses: a retrospective study

Fabiola Pontes Azevedo 09 August 2017 (has links)
As próteses metalocerâmicas ainda são apontadas como o tratamento de escolha em reabilitação oral por apresentarem altas taxas de sobrevivência, mesmo que o fator estético possa ser comprometido devido às propriedades óticas relacionadas à infraestrutura metálica. Além disso, há pouca informação na literatura científica sobre os fatores que levam às fraturas das próteses fixas metalocerâmicas. Com isso, o presente estudo teve como objetivo avaliar se a quantidade de elementos que compõe uma prótese, se a quantidade de elementos por retentor, se o tipo de prótese, se o tipo de pilar, se a localização da prótese, se o bruxismo e se a utilização de placa miorrelaxante influenciam na incidência de fraturas em próteses fixas metalocerâmicas. Para este estudo, foram selecionados 16 pacientes, totalizando 74 próteses metalocerâmicas, instaladas entre 2000 e 2010, que tiveram um acompanhamento mínimo de 4 anos. Foram coletados dados, como: gênero, idade, data de instalação das próteses e sistema cerâmico utilizado. Foi realizada a avaliação clínica considerando integridade da prótese, características do elemento antagonista e coleta da história odontológica em caso de fratura, além de um questionário para identificar provável ou possível bruxismo. Foram determinadas as taxas de sucesso, insucesso e sobrevivência da mesma. Os resultados mostraram que a taxa de sucesso das próteses metalocerâmicas instaladas foi de 87,8% e a taxa de sobrevivência foi de 89,1%. Além disso, a taxa de sucesso não foi influenciada pela idade (p=0,903), tempo de instalação (p=0,830), número de próteses na boca (p=0,872), número de elementos (p=0,937) e número de pilares (p=0,064). Para as variáveis qualitativas também não houve diferença estatística significante (p>0,05) entre as proporções das taxas de sucesso e insucesso. Contudo, os resultados mostraram que pacientes que não usavam placa miorrelaxante tiveram taxa maior de sucesso que os pacientes usuários de placa (p=0,004). Assim, pode-se concluir que as próteses metalocerâmicas apresentam altas taxas de sucesso e sobrevida garantindo a longevidade desse tipo de reabilitação. / Metal-ceramic prosthesis are still the treatment choice in oral rehabilitation because they present high survival rates, even if the aesthetic can be compromised due to optical properties related to metallic infrastructure. In addition, there is little information on scientific literature about factors that lead to fractures of fixed metalceramic prosthesis. The purpose of this study was to evaluate if prosthesis elements number, number of elements per prosthetic abutment, type of prosthesis, type of prosthetic abutment, the prosthesis location, bruxism and myorelaxant plaque influences on incidence of fractures in fixed metal-ceramic prosthesis. For this study, 16 patients were selected totaling 74 metal-ceramic dentures installed between 2000 and 2010 with a follow-up of at least 4 years. Data were collected, such as: gender, age, prosthesis installation date and the ceramic system used. Besides a questionnaire to identify probable or possible bruxism, a clinical evaluation was performed to evaluate prosthesis integrity, antagonist element characteristics and dental history in case of fracture. Success, failure and survival rates were determined. The results showed that the success rate of metal-ceramic prosthesis was 87.8% and the survival rate was 89.1%. In addition, the success rate was independent of age (p=0.903), installation time (p=0.830), number of prosthesis (p=0.872), elements (p=0.937) and abutments (p=0.064). The qualitative variables also did not show significant statistical results (p> 0.05) between success and failure rates. However, the results showed that patients who did not use myorelaxant plaque had a higher success rate than plaque users (p=0.004). Thus, it can be concluded that the metal-ceramic prosthesis has high success and survival rates, ensuring longevity of this type of rehabilitation.
62

Avaliação da resistência à fratura de próteses fixas provisórias implanto-suportadas variando o comprimento do cantilever e o tipo de fibra: fibras de vidro e fibras de poli(aramida) / Evaluation of the resistance to the fracture of temporary fixed prostheses implant-supported varying the extension of the cantilever and the fiber type: glass fibers and poliaramid fibers

Paola del Rosario Colán Guzmán 01 March 2007 (has links)
No tratamento reabilitador oral as restaurações provisórias são de suma importância. A resistência e a longevidade dos materiais utilizados em sua execução são críticas, principalmente em tratamentos prolongados e em espaços desdentados extensos. O objetivo deste trabalho foi avaliar a resistência e o modo de fratura de espécimes que simularam uma prótese fixa de três elementos variando o comprimento do cantilever (7, 14 e 21mm), confeccionadas em resina acrílica poli(metilmetacrilato) (PMMA) autopolimerizável, com e sem reforço em seu interior, construídos sobre componentes para implantes. Os reforços utilizados foram: fibras de vidro (Fibrante® - Ângelus®, Londrina, PR, Brasil) e fibras de poli(aramida) (Kevlar® - Du Pont®, USA). Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo controle, sem reforço. Os espécimes foram submetidos à carga compressiva até a fratura. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou não haver diferença estatística entre os grupos com respeito ao tipo de reforço, sendo que houve diferença estatística significante no que respeita ao comprimento do cantilever. Quando o comprimento do cantilever foi de 7mm todos os grupos apresentaram os valores médios de resistência a fratura, em N, significativamente maiores que os apresentados pelos grupos com 14 e 21mm de comprimento. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo Parcial. / In the oral rehabilitator treatment, the provisory restorations have extremely importance. The resistance and durability of materials used in the execution are critical, especially in extended treatments and in vast toothless spaces. The goal of this work was to demonstrate the resistance and the types of fracture of specimens that simulate a fixed prosthesis of three elements changing the extension of cantilever (7, 14 e 21mm), made of acrylic resin polymethylmethacrylate (PMMA) autopolymer, with and without reinforcement in its interior, built over implant components. The reinforcements used were: fiberglass (Fibrante® - Angelus®, Londrina, PR, Brazil) and poliaramid fiber (Kevlar® - Du Pont®, USA). The groups have 10 specimens each, including a group of control, without reinforcement. The specimens were submitted to a compressor charge until its fracture. The analysis of results (ANOVA, p < 0,05) for the test of resistance, showed that there is no statistic difference between the groups regarding the type of reinforcement; however, there is a significant statistic difference regarding the cantilever extension. When the extension of cantilever was 7mm, all groups showed medium values of resistance to fractures, in N, significant more than the showed by the groups with 14 and 21mm of extension. In relation with the types of fracture, the reinforcement groups show fractures more favorable to be repaired, even when they were partially fractured.
63

Efeito da aplicação prolongada do sistema adesivo convencional de dois passos na qualidade de restaurações de resina composta em lesões cervicais não cariosas: Ensaio clínico controlado, randomizado, duplo cego / Effect of the extended time of application of the conventional two-step adhesive system on the longevity of composite resin restorations in non-carious cervical lesions: a double-blind randomized clinical trial

Camargo, Márcio Neves 14 May 2018 (has links)
Submitted by Neusa Fagundes (neusa.fagundes@unioeste.br) on 2018-08-23T17:52:03Z No. of bitstreams: 2 Márcio_Camargo2018.pdf: 1289257 bytes, checksum: 6b195c00237854a0b325ec5a5c953cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-08-23T17:52:03Z (GMT). No. of bitstreams: 2 Márcio_Camargo2018.pdf: 1289257 bytes, checksum: 6b195c00237854a0b325ec5a5c953cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-05-14 / This double-blind randomized clinical trial evaluates the influence of increased application time in two adhesive system two-step etch-and-rinse (Peak® Universal Bond (P); Ultradent Products Ind and Single Link (SL); Angelus Dental Products Industry) applied in non-carious cervical lesions (NCCLs). Methods: A total of 219 restorations were randomly placed in 35 patients according to the following groups: P1 - applied according to the manufacturer’s; P2X – applied for the double time; SL1 and SL2X (the same application mode). The resin composite Amelogen (Ultradent) was placed incrementally. The restorations were evaluated immediately (baseline) and 6 months, using the FDI and USPHS criteria. Statistical analyses were performed using appropriate tests (=0.05). Results: Twenty-four restorations were lost at 6 months (4 for P1, 2 for P2X, 9 for SL1 and 9 for SL2X) (p < 0.05 between groups). Post-operative sensitivity wasn’t observed in any of the recall periods. Thrity-five restorations were considered to have minor discrepancies in marginal adaptation at the 6-month recall using the FDI criteria (8 for P1, 7 for P2X, 12 for SL1 and 8 for SL2X; p > 0.05 between groups). Ten restorations were considered to have minor discrepancies in marginal discoloration at the 6-month recall (2 for P1, 1 for P2X, 3 for SL1 and 2 for SL2X; p > 0.05 between groups). Conclusion: The increased application time of adhesive system two-step etch-and-rinse didn’t improve the clinical behavior of composite restorations placed in NCCLs. In the meantime, clinical behavior may be influenced by the composition of adhesive systems. / Este ensaio clínico controlado randomizado, duplo cego avaliou a influência do aumento do tempo de aplicação em dois sistemas adesivos convencionais de dois passos, Peak® Universal Bond (P) (Ultradent Products Ind) e Single Link (SL) (Angelus Dental Products Industry) aplicados para restaurar lesões cervicais não cariosas (LCNC). Material e Método: No desenho experimental um total de 219 restaurações foram distribuídas aleatoriamente em 35 pacientes de acordo com os seguintes grupos: P1 e SL1 - aplicados de acordo com o fabricante por 10s; P2X e SL2X - aplicados por 20 s. A resina composta Amelogen (Ultradent) foi colocada de forma incremental. As restaurações foram avaliadas imediatamente (baseline), e em 6 meses, utilizando os critérios FDI e USPHS. As análises estatísticas foram realizadas utilizando testes de Friedman e Mc Nemar (α = 0,05). Resultado: Vinte e quatro restaurações foram perdidas aos 6 meses (4 para P1, 2 para P2X, 9 para SL1 e 9 para SL2X) (p<0,05). A sensibilidade pós-operatória não foi relatada durante a avaliação. Trinta e cinco restaurações apresentaram pequenas discrepâncias na adaptação marginal usando os critérios FDI (8 para P1, 7 para P2X, 12 para SL1 e 8 para SL2X; p>0,05 entre os grupos). Oito restaurações apresentaram pequena discrepância no manchamento marginal na avaliação de 6 meses (2 para P1, 1 para P2X, 3 para SL1 e 2 para SL2X; p> 0,05 entre grupos). Conclusão: Aumentar o tempo de aplicação do sistema adesivo convencional de dois passos não melhora o desempenho clínico das restaurações em resina compostas realizadas em LCNCs. Entretanto, este desempenho/performance pode ser influenciado pela composição dos sistemas adesivos.
64

"Estudo da interface adesiva em restaurações que combinam resinas com diferentes módulos de elasticidade" / Evaluation of the adhesive interface of restorations combining composite resins with different elastic modulus

Silvia Kenshima 11 December 2001 (has links)
O objetivo deste estudo foi o de avaliar uma técnica teste para inserção de resinas compostas combinadas e duas técnicas convencionais, quanto à qualidade da interface adesiva, em restaurações classe V realizadas em dentes bovi nos. Foram utilizadas as resinas compostas (Z-250 e Durafill VS) com o sistema adesivo (Single Bond) em 30 preparos confeccionados nas superfícies vestibulares dos dentes (fator C= 3). Portanto, foram analisadas seis técnicas r estauradoras com 5 repetições: incremental vertical (Z-v e D-v), incremental oblíqua (Z-o e D-o), e teste [Z-t e D-t (forramento das paredes cavitárias com uma resina e preenchimento com a outra)]. Os espécimes foram armazenado s por 24 h em água a '37 GRAUS'C e secionados no sentido V-L, originando 4 superfícies para obtenção de dados por espécime, as quais foram condicionadas (ácido fosfórico a 37%, por 3s) e coradas (azul de metileno a 0,5%, por 2s ). Para mensurar o comprimento (c) e a largura (l) dos gaps, a interface adesiva foi examinada por microscopia ótica (400X). A largura média ('mü'm) dos gaps foi calculada através da equação lm = 'sigma' ('c IND. n' x 'l IND. n ') / 'sigma' 'c IND. n'. Os resultados obtidos pelo tratamento estatístico dos dados (ANOVA para Medidas Repetidas) mostraram que somente a Técnica e a Superfície de leitura foram significativas (p < 0,05). Concluiu-se com base n estes resultados que a técnica teste apresentou qualidade de interface inferior, ou seja, gaps mais largos e que, a largura média dos gaps relativa à seção central foi maior que a das superfícies externas medidas / The objective of this study was to evaluate the quality of the adhesive interface of an experimental placement technique, which combines different composite resins, and two conventional techniques used in class V restorations i n bovine teeth. Two composite resins were applied in this study (Z-250 and Durafill VS) with the adhesive system (Single Bond) in 30 cavity preparations made on the labial surface of the teeth (C-factor = 3). So, six restorativ e techniques were applied with 5 samples each: incremental vertical (Z-v e D-v), incremental oblique (Z-o e D-o), and experimental [Z-e and D-e (lining the cavity walls with one of the resins and bulk filling with the other)]. After 24-hour-storage in water (37° C), each specimen was sectioned (LB) generating 4 surfaces for gap assessment that were previously acid etched (phosphoric acid 37% for 3s) and stained (metilene blue 0.5% for 2s). The adhesi ve interface was examined by optic microscopy at 400X and both length (l) and width (w) of gaps were measured (´mü´m). The mean gap widths were calculated by the equation w = ´sigma´ (´c IND.n´ x ´l IND.n´) / ´sigma´ ´c IND. n´ . The results obtained from the data's statistical analysis (ANOVA for Repeated Measurements) showed that only Technique and Surface were significant (p < 0,05). Based in this results it was concluded that the experimental techni que showed the worst interface quality, which means that gap widths were larger and that the gap width means of the central section were higher than the measured external ones
65

"Avaliação do desempenho clínico, radiográfico e da microinfiltração marginal de restaurações classe II com um cimento de ionômero de vidro modificado por resina e com uma resina composta 'condensável' em molares decíduos: dois anos de acompanhamento".

Edmêr Silvestre Pereira Júnior 10 May 2002 (has links)
O objetivo deste estudo foi avaliar durante 2 anos a efetividade do cimento de ionômero de vidro modificado por resina (Vitremer - 3M) e da resina composta “condensável” (Solitaire - Kulzer) em classe II de molares decíduos. Realizou-se a análise clínica qualitativa, radiográfica, avaliação direta nos molares decíduos esfoliados e microinfiltração marginal da restauração nos mesmos. Este estudo foi composto de 64 restaurações classe II de cimento de ionômero de vidro modificado por resina (Vitremer) e 59 de resina composta “condensável” (Solitaire). O preparo cavitário de classe II foi realizado de acordo com a extensão do processo de cárie, limitando-se apenas ao corte de entrada para o acesso à lesão e a remoção de todo tecido cariado, observando-se os princípios da dentística operatória moderna, sem extensão preventiva, conservando-se a maior quantidade de estrutura dentária sadia possível. Os materiais restauradores foram manipulados e inseridos de acordo com as instruções do fabricante, sendo que o Vitremer foi inserido com seringa Centrix (DFL) e a Solitaire com espátula antiaderente em incrementos. As restaurações foram avaliadas clinicamente no início, aos 6, 12, 18 e 24 meses pelo critério United States Public Health Service modificado RYGE e CVAR. A tomada radiográfica interproximal padronizada foi realizada no início e aos 24 meses. Após a esfoliação os trinta e seis dentes foram armazenados em água destilada com timol a 1% com finalidade de inibir o crescimento bacteriano. Estes foram analisados diretamente para avaliar a presença de cárie recorrente nas restaurações e a microinfiltração marginal. Posteriormente, as raízes foram seladas com resina composta Z 100 (3M) e aplicadas 2 camadas de esmalte de unha a 1mm das margens da restauração, sendo os espécimes imersos em solução de fucsina básica a 0.5%, à temperatura de 37o C por 24 horas. Após esse período, os mesmos sofreram lavagem em água corrente por 24 horas. Para o seccionamento, os espécimes foram incluídos em resina acrílica autopolimerizável para serem levados à máquina de corte. Cada dente sofreu 3 cortes com um disco diamantado, no sentido mésio-distal. O tamanho da recidiva de cárie, a análise indireta do tamanho das restaurações e a microinfiltração marginal na parede cervical de cada restauração dos dentes esfoliados foram avaliadas através de medidas lineares em um programa de computador (Sigma Scan). Utilizou-se o teste de Mann-Whitney para a análise entre materiais, e para a análise no mesmo material restaurador, porém em períodos diferentes de observação, utilizou-se o teste pareado de Wilcoxon. Já para a análise de medidas realizadas nas recidivas de cárie dos dentes esfoliados e da microinfiltração marginal utilizou-se o teste “t”. O nível de significância de 5% foi adotado em todos os testes. Os resultados clínicos demonstraram após os 24 meses de avaliação que o Vitremer apresentou melhores resultados quando comparado a Solitaire. Os dados foram, respectivamente, na descoloração marginal de 89.00% e 33.89%; na forma anatômica de 56.25% e 11.86%; na integridade marginal de 46.87% e 15.25% e, na manutenção do contato proximal de 92.18% e 69.49%. Com relação à estabilidade de cor os dados foram de 79.68% e 80.35%, e quanto à textura da superfície foram de 37.50% e 81.35%, sendo que a Solitaire apresentou melhores resultados. Estas porcentagens são relativas ao escore Alpha na avaliação de 24 meses. Verificou-se que não houve influência geral direta, da remoção do teto da câmara pulpar para a terapia pulpar, no comportamento clínico dos materiais restauradores, somente em alguns quesitos de avaliação como descoloração marginal, textura da superfície e contato proximal é que os dentes que sofreram terapia pulpar apresentaram um desempenho um pouco inferior, sendo na maioria praticamente igual, ou até superior como no caso da estabilidade de cor com relação ao Vitremer. Quanto ao desempenho clínico avaliado através de radiografias, verificou-se, com relação à conformidade da restauração com o dente em relação ao contorno proximal, uma semelhança entre os grupos, não apresentando diferenças estatísticas, pois o Vitremer apresentou escore médio aos 24 meses de 1.08 e a Solitaire de 1.29. Já com relação à presença de radiolucidez na parede gengival, os resultados foram estatisticamente significantes, sendo que a resina composta apresentou um número maior de dentes com área radiolúcida em esmalte e dentina em relação ao Vitremer, na avaliação de 24 meses, com média de 0.17 e 1.23, respectivamente. Ao analisar o desempenho clínico com relação ao tamanho da restauração e o dente em que esta se encontra, verifica-se uma conformidade nos resultados, onde o tamanho da restauração tende a não influenciar no resultado do material. A presença de cárie recorrente, qualitativa e quantitativa, avaliada nos dentes esfoliados, foi marcante na face proximal sendo que a resina composta empregada apresentou um número maior de lesões cavitadas, sendo este número estatisticamente significante, pois a média da Solitarie foi de 3.82mm2 e do Vitremer 0.11mm2 de recidiva cavitada. Na face oclusal houve uma diferença estatisticamente significante entre os materiais testados, sendo a média da Solitaire de 1.25mm2 de recidiva e o Vitremer não apresentou recidiva cavitada na oclusal. Ao analisar a microinfiltração marginal nos dentes esfoliados através do uso de corante, verificou-se uma maior penetração do corante na parede gengival nos dentes restaurados com resina composta, apresentando 1.73mm de média na penetração do corante e 0.35mm de média para o Vitremer, sendo a diferença estatisticamente significante. Nas avaliações realizadas neste estudo, verificou-se que o cimento de ionômero de vidro modificado por resina (Vitremer) apresenta condições favoráveis de desempenho clínico, radiográfico e menor microinfiltração marginal em restaurações classe II de molares decíduos, no período avaliado, superando o desempenho da resina composta “condensável” (Solitaire). / The purpose of this study was to evaluate for two years the clinical performance of a resin-modified glass ionomer cement (Vitremer - 3M) and the “condensable” composite resin (Solitaire - Kulzer) in the restoration of class II cavities in primary teeth. Clinical, radiographic, direct following exfoliation in the primary molars and marginal microleakage evaluations were performed. A total of 64 class II cavities in the primary molar was restored with resin modified glass ionomer cement (Vitremer - 3M) and 59 class II cavities in the primary molars with “condensable” composite resin (Solitaire - Kulzer). The preparation was accomplished according to the extension of the decay process. The dentist placed resinmodified glass ionomer cement according to the manufacturer’s recommendations. First, he placed a dentin primer and light-polymerized it. Then, he hand-mixed the fluoroaluminosilicate glass powder base with the poliacrilic acid, placed it in the cavity preparation (Centrix) and then exposed it to visible light for initial polymerization. The composite resin Solitaire was placed in the cavity preparation in increments. Each restoration was directly and clinically evaluated at baseline and at 6, 12, 18, 24 months, based on the modified United Stated Public Health Service methodological technique for evaluations. Standardized bitewing radiograph were accomplished in the baseline and at 24 months. After exfoliation, the teeth were stored in distilled water with timol 1% with purpose of inhibiting the bacterial growth. Visual inspection was carried out in the thirty-six restorations collected after exfoliation, to evaluated recurrent decay and marginal microleakage. The roots were sealed with composite resin Z 100 (3M) and applied two layers of fingernail enamel at 1mm of the margins of the restorations, being the specimens immersed in basic fucsin solution, at 0,5%, at a temperature of 37oC, for 24 hours, and rinsed in running average water for 24 hours, sectioned and evaluated. Each sample was included in auto-cured resin and mesiodistal planes, with a diamond disk had three cuts. Decay size, the indirect analysis of the size restorations and the marginal microleakage in the cervical wall, were measured in a computer program (Sigma Scan). Mann-Whitney’s test was used for the analysis among the materials, and for the analysis in the same restorative material, although in different observation periods; of Wilcoxon paired test used. As to the analysis of measures accomplished in the decay of the teeth after exfoliation and marginal microleakage, the “t” test was used. The significance level of 5% was used in all tests. The clinical results demonstrated, after 24 months of evaluation, that Vitremer presented better results when compared with Solitaire, begin: the marginal discoloration, 89,00% and 33,89%; anatomic form, 56,25% and 11,86%; marginal integrity, 46,87% and 15,25%; maintenance of interproximal contact, 92,18% and 69,49%; except for color stability, 79,68% and 80,35%; and surface texture, 37,50% and 81,35% Solitaire presented better results, being these resulted related to percentages of the score Alpha, in the evaluation of 24 months. This study verified that there is not a direct, general influence when removing the pulpal roof chamber for the pulpal therapy, on the clinical behavior of, restoring materials. Only in some evaluation requirements, as marginal discoloration, surface texture and maintenance of interproximal contact is that the teeth that suffered pulpal therapy presented a little inferior performance, being practically equal in most instances, or even superior, in the case of color stability, in relation to Vitremer. The clinical performance was evaluated through bitewing radiographs, regarding the conformity of the restoration with the tooth in relation to the proximal contour, a similarity among groups, not presenting statistical differences, because Vitremer showed medium score at 24 months of 1,08 and Solitaire 1,29. As to the presence of a radio-lucid area in the gingival wall, the results were statistically significant and Solitaire presented a larger number of teeth with radio-lucid areas in the enamel and dentin, in relation to Vitremer, in the evaluation of 24 months, with an average score of 0,17 and 1,23, respectively. When analyzing the clinical performance in relation to the size of the restoration and the tooth in which localized, a conformity is verified in the results, where the size of the restoration tends to not influence the result of the material. The quantitative and qualitative caries recurrence evaluation in the teeth, after exfoliation, was greater the proximal surface of the composite resin, presenting a larger number of carious lesions, being this number statistically significant, since the average of Solitarie was 3,82mm2 and that of Vitremer 0,11mm2 of recurrent caries. In the oclusal surface, there was a significant statistically difference among the tested materials, being the average of Solitaire 1,25 mm2 of recurrent caries and Vitremer did not present recurrent caries in the oclusal surface. When analyzing the marginal microleakage in the teeth, after exfoliation through the use of dye, a larger penetration of the it was verified in the gingival wall in the teeth restored with composite resin, presenting 1,73 mm in average in the penetration of the dye and 0,35mm in average, for Vitremer, being the differences statistically significant. In the evaluations accomplished in this study, it was verified that the resin-modified glass ionomer cement (Vitremer) presented a favorable clinical and radiographic performance, and smaller marginal microleakage in class II restorations in primary molars, in the assessed period, surpassing the performance of the "condensable" composite resin (Solitaire).
66

Influence of veneer/framework interface on the mechanical behavior of ceramic veneers = Influência da união entre a cerâmica de cobertura e a infraestrutura de zircônia sobre o comportamento mecânico da cerâmica de cobertura / Influência da união entre a cerâmica de cobertura e a infraestrutura de zircônia sobre o comportamento mecânico da cerâmica de cobertura

Lazari, Priscilla Cardoso, 1988 09 February 2013 (has links)
Orientadores: Eduardo Passos Rocha, Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T13:32:48Z (GMT). No. of bitstreams: 1 Lazari_PriscillaCardoso_M.pdf: 1639224 bytes, checksum: 04a00f1542f02dc5f013332a3d16a57c (MD5) Previous issue date: 2013 / Resumo: O uso do óxido de zircônia para a confecção de infraestruturas de coroas totais cerâmicas tem se expandido devido às suas excelentes propriedades mecânicas, entretanto estudos recentes demonstram a maior ocorrência de fraturas na cerâmica de cobertura de coroas totais com infraestrutura de zircônia quando comparados ao uso de infraestrutura metálica. Assim, o objetivo deste estudo foi avaliar o comportamento mecânico da cerâmica de cobertura sobre infraestrutura de zircônia ou metal, variando a união entre ambas, com o método dos elementos finitos tridimensional não linear. Os modelos geométricos de um incisivo central superior, portando uma coroa total com infraestrutura de zircônia ou prata/paládio e cerâmica de cobertura sobre retentores dente natural ou implante, foram confeccionados com os softwares SolidWorks Premium 2012 e Mimics. Os grupos em estudos foram: C - Coroa metalocerâmica com infraestrutura em prata/paládio cimentada sobre dente natural; Cz - Coroa cerâmica com infraestrutura em zircônia cimentada sobre dente natural; Ci - Coroa metalocerâmica com infraestrutura em prata/paládio, cimentada sobre implante cone morse; Czi - Coroa cerâmica com infraestrutura em zircônia, cimentada sobre implante cone morse. Os coeficientes de atrito entre a cerâmica de cobertura e a infraestrutura, e a interface de contato foram estabelecidos em 0,3 ou totalmente unidos, simulando desde uma união insatisfatória até uma união perfeita. Foram realizados dois carregamentos (C): C1- 49 N aplicados no terço incisal da superfície palatina com inclinação de 45º em relação ao longo eixo do dente, simulando contato em máxima intercuspidação habitual; C2- 25,5N aplicados perpendicularmente à borda incisal da coroa, simulando contato do tipo "topo a topo". Os valores de tensão principal máxima (?max), tensão de cisalhamento (µmax) e os deslocamentos (?max) foram obtidos para a cerâmica de cobertura, e tensão de von Mises (?vM) obtidos para as infraestruturas de zircônia ou prata/paládio. Os maiores valores de tensão foram observados para a cerâmica de cobertura com o coeficiente de fricção 0.3 independente do material utilizado como infraestrutura. Entretanto, quando os modelos apresentavam-se com uma união perfeita entre as estruturas, as próteses metalocerâmicas apresentaram valores menores de tensão quando comparadas com a infraestrutura de zircônia. Os valores de tensão para os modelos sobre implante apresentaram valores de tensão inferiores aos observados nos modelos sobre dente, independente do material da infraestrutura. Dentro das limitações do estudo, podemos concluir que a união deficiente entre a cerâmica de cobertura e a infraestrutura da prótese afeta a resistência à fratura da cerâmica de cobertura, tornando-a susceptível à falhas independente do material da infraestrutura ou do suporte da coroa total / Abstract: The excellent mechanical properties of zirconium YTZ-P make it a viable option for constructing the framework of metal-free crowns. However, recent studies indicate the occurrence of failures in ceramic veneer crowns with zirconia framework. The aim of this study was to use three-dimensional nonlinear finite element analysis to evaluate the mechanical behavior of ceramic veneers, partially debonded or bonded, over zirconia frameworks under two conditions of veneer/framework bond integrity and support by implant or natural tooth. Three-dimensional finite element analysis was used to compare the mechanical behavior of ceramic veneers on zirconia and metal frameworks under two conditions of bond integrity. The groups were created with the crowns partially bonded (0.3 frictional coefficient) or completely bonded): C - Crown with silver/palladium framework cemented onto natural tooth; Cz - Ceramic crown with zirconia framework cemented onto natural tooth; Ci - Crown with silver/palladium framework cemented on implant morse taper; CZI - Ceramic crown with zirconia framework cemented onto implant morse taper. The test loads consisted of 49 N applied to the palatal surface at 45º to the long axis of the crown and 25.5 N applied perpendicular to the incisal edge of the crown. The maximum principal stress (?max), shear stress (?max) and deformation (?max) were calculated for the ceramic veneer and the von Mises stress (?vM) was determined for the framework. Partially debonded of the veneer to the framework (friction coefficient 0.3) increased stress concentrations in all structures. The metal-ceramic crowns experienced lower stress values than all ceramic crowns in models simulating a perfect bond between the ceramic and framework. Frameworks cemented to tooth exhibited greater stress than frameworks cemented to implants regardless of the material used. The incomplete bonding between the ceramic veneer and the framework prosthesis affects the mechanical performance of the ceramic veneer, making it susceptible to failure independent of the material framework or full crown support / Mestrado / Protese Dental / Mestra em Clínica Odontológica
67

The effect of platform connection and abutment material on stress distribution in single anterior implant-supported restoration = a 3D finite element analysis = A influência do material e conexão de pilares na distribuição de tensões em coroas anteriores sobre implantes: um estudo pelo método dos elementos finitos / A influência do material e conexão de pilares na distribuição de tensões em coroas anteriores sobre implantes : um estudo pelo método dos elementos finitos

Carvalho, Marco Aurélio de, 1989- 23 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T17:33:02Z (GMT). No. of bitstreams: 1 Carvalho_MarcoAureliode_M.pdf: 8351585 bytes, checksum: 5577f7f5bed23cd367f52fac8602f7af (MD5) Previous issue date: 2013 / Resumo: A reabilitação de elementos unitários com implantes osseointegrados na região anterior da maxila é um cenário desafiador diante dos requisitos estéticos e funcionais. Nesse contexto, diferentes tipos de conexões pilar/implante e materiais constituintes do pilar surgiram no intuito de suprir as exigências estético-funcionais atuais. A distribuição de tensão no sistema de restaurações cimentadas a pilares cerâmicos parafusados a implantes é um fator importante na elucidação do processo de falha e também na previsibilidade de sucesso do tratamento. O objetivo do trabalho foi avaliar o efeito de diferentes conexões e materiais de pilar na distribuição de tensões em restaurações sobre-implante unitárias anteriores através do método dos elementos finitos. Foram obtidos 9 grupos experimentais a partir da combinação de três conexões protéticas (hexagonal externa-HE, hexagonal interna-HI e cone morse-CM) e três tipos de material constituinte do pilar (titânio-Ti, zircônia-Zr e híbrido-H): HETi, HEZr, HEH, HITi, HIZr, HIH, CMTi, CMZr, CMH. Com o auxilio do software de modelagem 3D (SolidWorks 2012 Corp., Concord, MA, EUA), foram obtidos os modelos geométricos que se constituíam de: segmento anterior de maxila; implantes HE, HI e CM construídos a partir do implante Titamax Ex 4x13mm (Neodent, Curitiba, Brasil); pilar do tipo Munhão Anatômico CM (Neodent, Curitiba, Brasil) em titânio, zircônia e híbrido (corpo em zircônia e base em titânio) para implantes HE, HI e CM; coroa do elemento 21 em dissilicato de lítio cimentada com cimento resinoso. Foi aplicada uma carga, de 49N em 45 graus em relação ao longo eixo do dente, de forma contínua em 6 etapas desde a região de cíngulo à borda incisal, no intuito de simular o movimento de excursão da guia incisal. O critério de Tensão Equivalente de von Mises (?vM) foi utilizado para a avaliação quantitativa e qualitativa dos implantes e pilares entre os nove grupos. As tensões máxima (?max) e mínima (?min) principais foram utilizadas para a avaliação quantitativa entre os pilares de zircônia e corpo de zircônia de pilares híbridos. Os maiores valores de ?vM (MPa) para o pilar foram encontrados nos grupos CMZr, CMH e CMTi (315,61; 293,61; 289,36 respectivamente), e os menores nos grupos HEH, HITi e HIH (91,70; 97,58; 100,65, respectivamente). Os valores ?max e ?min foram menores nos grupos H que nos Zr. Qualitativamente, a concentração de tensão se deu na interface pilar/implante em todos os grupos, independente da conexão ou material do pilar. Concluiu-se que o tipo de conexão teve maior influência que o material constituinte nas tensões acumuladas nos pilares, sendo que os pilares híbridos tiveram comportamento mecânico semelhante aos de titânio, que por sua vez foi melhor que os pilares em zircônia / Abstract: The anterior single crown reconstruction is still a challenging scenario in implant dentistry. Within the esthetic and functional demand, different platform connections and abutment material emerged for better outcomes. The stress distribution through the structure is an important factor to be elucidated for better fail process understanding and also to the treatment success predictability. Therefore, the aim of this study was to evaluate the effect of different abutment material and platform connection on stress distribution in single anterior implantsupported restorations, through the finite element method. Nine experimental groups were design from the combination of three platform connection (external hexagon-EH, internal hexagon-IH and morse tapered-MT) and three abutment material (titanium-Ti, zirconia-Zr and hybrid-H): EHTi, EHZr, EHH, IHTi. IHZr, IHH, MTTi, MTZr, MTH. Finite element models were obtained with the aid of a modeling software (SolidWorks 2012 Corp., Concord, MA, USA), and consisted of: EH, IH and MT implants modeled from Titamax Ex 4x13mm (Neodent, Curitiba, Brazil); abutment modeled from Anatomic Abutment CM (Neodent, Curitiba, Brazil) in titanium, zirconia and hybrid (two-piece abutment); lithium disilicate central incisor crown cemented over the abutment. The occlusal loading, consisted of a magnitude of 49N in 45 degrees to the implant long axis, was applied in six steps in order to simulate the incisal guidance. The equivalent von Mises criterion (?vM) was used for both qualitative and quantitative evaluation of implant and abutment among all groups. The maximum (?max) and (?min) minimum principal stresses were obtained for numerical comparison of zirconia abutment and zirconia abutment body. The highest abutment ?vM (MPa) occurred in MTZr, MTH and MTTi (315.61; 293.61; 289.36 respectively); and the lowest in EHH, IHTi and IHH (91.70; 97.58; 100.65, respectively). The ?max and ?min values were lower in H groups than Zr groups. The stress distribution concentrated in the abutment/implant interface in all groups, regardless the platform connection or abutment material. It was concluded that the platform connection had more influence than abutment material on stress values and distribution on abutments, and the stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections / Mestrado / Protese Dental / Mestre em Clínica Odontológica
68

Influência da espessura da resina de baixa viscosidade e da técnica restauradora na infiltração marginal em restaurações realizadas com compósito dental / / Influence of the thickness of two flowable composite resins and the restorative technique on microleakage of simulated class II composite resin restorations

Hernandes da Fonseca, Natália Maria Aparecida, 1986- 06 October 2011 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-19T00:32:03Z (GMT). No. of bitstreams: 1 HernandesdaFonseca_NataliaMariaAparecida_M.pdf: 1231211 bytes, checksum: ee28923febbad9b353d500bf886bdc59 (MD5) Previous issue date: 2011 / Resumo: O objetivo deste estudo in vitro foi avaliar quantitativamente a infiltração marginal ao redor de restaurações dentais, realizadas com compósito resinoso microhíbrido, variando a espessura, a resina de baixa viscosidade e a técnica restauradora. As superfícies proximais de cento e trinta incisivos bovinos foram preparadas e divididas de acordo com a resina de baixa viscosidade (Filtek Z350 Flow - Z350F e SureFil®SDRTM Flow - SUR), espessura da resina de baixa viscosidade (0,5 mm, 1,0 mm ou 2,0 mm) e técnica restauradora (resina de baixa viscosidade aplicada na parede gengival, até o ângulo cavo-superfícial - CS; resina de baixa viscosidade aplicada na parede gengival, até a junção amelo-dentinária - JAD) (n=10). Um grupo controle foi realizado sem o uso de resina de baixa viscosidade. Após os procedimentos restauradores (resina microhíbrida Filtek Z250) e termociclagem, os dentes foram imersos em azul de metileno por 2 horas. As amostras foram trituradas e o pó foi preparado para a análise de absorbância em espectrofotometria. Os resultados foram lidos e interpretados através da análise estatística ANOVA (p=0,05) em esquema fatorial 2 x 3 x 2 com 1 tratamento adicional e teste de Tukey (p=0,05). A comparação com o grupo controle foi realizada pelo teste de Dunnett (p ?0,05). Os resultados mostraram que não houve diferença estatística entre os compósitos de baixa viscosidade testados. Para SUR, não houve diferença estatística entre as técnicas restauradoras. Para Z350F, a técnica JAD apresentou menor infiltração marginal quando utilizou-se camada de 1,0 ou 2,0 mm de espessura. E para ambas as técnicas e compósitos de baixa viscosidade, 0,5 mm de espessura apresentou menor infiltração que 2,0 mm. Comparando com o grupo controle, Z350F (0,5 mm para técnica CS e JAD, e 1,0 mm para técnica JAD) e SUR (0,5 mm para a técnica JAD) apresentaram menor infiltração marginal. É possível concluir que o uso de menor espessura de resina de baixa viscosidade proporcionou menor infiltração marginal, sugerindo melhor selamento da interface dente restauração / Abstract: The aim of this in vitro study was to evaluate the microleakage in Class II cavities, restored with dental composite, varying the thickness of two flowable composite resins and the restorative technique. One hundred and thirty cavities were prepared on proximal surfaces of bovine teeth, and were randomly divided according to the flowable composite resin (Filtek Z350 Flow - Z350F and SureFil®SDRTM Flow - SUR), thickness of flowable composite (0.5, 1.0, or 2.0 mm) and restorative technique (flowable composite applied until cavosurface angle - CS; or flowable composite applied until amelo-dentinal junction - ADJ) (n=10). A control group was performed without using flowable composite. Following restorative procedures (microhibrid composite Filtek Z250) and the thermocycling, the samples were immersed in methylene blue for 2 hours. The samples were ground and the powder was prepared for analysis in an absorbance spectrophotometer. All results were statistically analyzed by three-way ANOVA and Tukey test, and Dunnett test were applied to comparisons with control group (p?0.05). Results showed that there was no statistical difference between the flowable composite tested. For SUR, there is no statistical difference between the restorative techniques. For Z350F, the restorative technique ADJ showed lower microleakage than technique CS only when the flowable composite was applied to 1.0 and 2.0 mm thickness. And for both techniques and flowable composite resins, 0.5 mm sample thicknesses showed lower microleakage than 2.0 mm thickness. Comparing with the control group, the lower thickness of Z350F (0.5 mm for technique CS and 2 and 1.0 mm for JAD) and SUR (0.5 mm for technique ADJ) showed lower microleakage. It is possible to conclude that a lower thickness of flowable composite resin provided lower microleakage, suggesting better sealing tooth-restoration interface / Mestrado / Dentística / Mestre em Clínica Odontológica
69

Cimento de ionômero de vidro é melhor do que resina composta em restaurações classe II de dentes decíduos? Uma revisão sistemática com meta-análise /

Dias, Ana Giselle Aguiar. January 2016 (has links)
Orientador: Juliano Pelim Pessan / Coorientador: Alberto Carlos Botazzo Delbem / Banca: Rogério de Castilho Jacinto / Banca: Douglas Roberto Monteiro / Banca: Daniela Rios / Banca: Thiago Cruvinel da Silva / Resumo: O objetivo do presente estudo foi realizar uma revisão sistemática e meta-análise (MA) sobre o desempenho clínico do cimento de ionômero de vidro (CIV) comparado ao de resina composta (RC) em restaurações classe II em dentes decíduos. Foi realizada uma busca abrangente nas bases PubMeb, Scopus, Web of Science, LILACS-BBO, Cochrane Library, Clinical Trials e OpenGrey, sem restrições de data ou idioma. Foram utilizados termos Mesh, sinônimos e palavras chave, adaptados para cada base de dados. Também foi feita busca manual na lista de referências dos artigos selecionados. Foram incluídos 5 ensaios clínicos controlados e randomizados e 3 estudos clínicos não randomizados, que compararam o desempenho clínico, avaliado pela presença de lesões de cárie secundária, descoloração marginal, adaptação marginal, forma anatômica e retenção e desgaste do material restaurador de restaurações de classe II realizadas com CIV em comparação com restaurações de RC em dentes decíduos. Quinze estudos completos foram lidos na íntegra, dos quais 8 foram incluídos na síntese qualitativa (risco de viés) e quantitativa (meta-análise). A heterogeneidade variou de baixa a moderada nas 12 MAs realizadas dos 8 estudos, com acompanhamento de 6 a 48 meses (38 a 73%), não havendo diferença significativa entre os dois materiais na análise final (overall effect). A diferença de risco (intervalo de confiança 95%; valor de p) entre RC e CIV quanto a falhas foi de -0,03 (-0,11 - 0,05; p= 0,41); quanto a adaptação ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to perform a systematic review and meta - analysis (MA) on the clinical performance of glass ionomer cement (GIC) compared to composite resin (CR) in class II restorations in deciduous teeth. A comprehensive search was performed on the PubMeb, Scopus, Web of Science, LILACS - BBO, Cochrane Library, Clinical Trials and OpenGrey databases, without dat e or language restrictions. Mesh terms, synonyms and key words were used, adapted for each database. Manual search was also performed on the list of references of the selected articles. Five randomized controlled trials and three non - randomized clinical tr ials comparing the clinical performance (assessed by the presence of secondary caries lesions, marginal discoloration, marginal adaptation, anatomical shape, and retention and wear of restorative material) were included in class restorations II performed w ith GIC compared to RC restorations in deciduous teeth. Fifteen complete studies were read in full, of which 8 were included in qualitative (risk of bias) and quantitative synthesis (meta - analysis). The heterogeneity ranged from low to moderate in the 12 M As from the 8 studies, with a follow - up of 6 to 48 months (38 to 73%), with no significant difference between the two materials in the final analysis (overall effect). The risk difference (95% confidence interval, p value) between RC and GIC for failure wa s - 0.03 ( - 0.11 - 0.05; p = 0.41); for marginal adaptation was - 0.01 ( - 0.06 - 0.05; p = 0.8); for marginal discoloration it was 0.07 ( - 0.11 - 0.26, p = 0.44), and for the anatomical form it was 0.00 ( - 0.04 - 0.05; p = 0.84). Regarding the presence of seconda ry caries lesion, the corresponding value was 0.07 (0.02 - 0.12; p = 0.01). The overall risk difference for clinical performance was 0.03 ( - 0.01 - 0.06, p = 0.17). For all the analyzed...(Complete abstract click electronic access below) / Doutor
70

Comportamento clínico das restaurações adesivas em dentes decíduos anteriores e seu impacto em aspectos econômicos e na qualidade de vida relacionada a saúde bucal das crianças / Clinical performance of adhesive restorations in anterior primary teeth and its impact on economic aspects and children\'s oral health-related quality of life

Vargas, Jhandira Daibelis Yampa 25 February 2019 (has links)
A integridade dos dentes anteriores decíduos pode ser afetada por vários fatores. Em consequência, aspectos como dor, sensibilidade, dificuldade para mastigar, más oclusões, complicações sistêmicas e baixa autoestima (devido ao comprometimento estético), podem agravar a situação das crianças que apresentam essas lesões. Na tentativa de devolver a funcionalidade e estética desses dentes, surge a necessidade de realização de procedimentos restauradores. No entanto, a literatura disponível não oferece informações suficientes sobre a efetividade, empregabilidade, durabilidade ou custo-efetividade das técnicas e materiais utilizados para dentes anteriores decíduos. O objetivo deste trabalho é investigar alguns desses aspectos relacionados às abordagens restauradoras executadas atualmente para dentes anteriores decíduos. Trata-se de um estudo retrospectivo, de coortes históricas, baseado em dados de prontuários de crianças de 3 a 6 anos de idade com dentes anteriores restaurados, alocadas em estudos clínicos com outros propósitos. Dados relacionados aos procedimentos restauradores, socioeconômicos, de qualidade de vida associada à saúde bucal foram coletados dos prontuários, do início do estudo e dos 24 meses de acompanhamento. O estudo será descrito em três partes. No primeiro capitulo narramos a real prevalência de necessidade restauradora para dentes anteriores decíduos dentro de uma amostra de crianças que busca por tratamento odontológico, bem como o impacto dessa necessidade na qualidade de vida das crianças. No segundo capitulo foi avaliado o índice de sucesso das restaurações realizadas em dentes anteriores, sob isolamento relativo, com Resina Composta (CR) e com Ionômero de vidro modificado por resina (RMGIC), identificando os fatores de risco para a ocorrência de falhas. No terceiro capitulo, foi realizada uma análise econômica para verificar se o RMGIC seria uma alternativa viável, nas referidas circunstâncias. Nossos achados sugerem que a necessidade de procedimentos restauradores em dentes anteriores não é muito alta, porém essa necessidade tem um impacto negativo na qualidade de vida das crianças envolvidas. Quem geralmente precisa desse tipo de restauração são as crianças com maior experiência de cárie. Quando são realizadas restaurações adesivas em este tipo de dentes, sob isolamento relativo, aquelas realizadas com CR presentam maior necessidade de reintervenções (falhas), e isto faz que o custo se equivalesse ao RMGIC a longo prazo. As falhas aconteceram mais quando a restauração envolvia superfícies proximais. A qualidade de vida das crianças que receberam restaurações foi melhorada, independentemente do material usado, mas a ocorrência de falhas contribuiu para a piora. Além disso, o custo adicional de se utilizar o RMGIC é baixo e compensa sua superioridade comparado à CR. Assim, para restaurar dentes anteriores decíduos, sob isolamento relativo, o RMGIC é uma alternativa mais eficaz e eficiente comparada à RC. / The soundness of anterior primary teeth can be affected by several factors. Consequently, aspects such as pain, sensitivity, chewing impairment, malocclusions, systemic complications and low self-esteem (due to aesthetic impairment) can aggravate the situation of children with these lesions. Restorative procedures emerge to restore the functionality and aesthetics of these teeth. However, the available literature does not provide sufficient information about the effectiveness, durability or cost-effectiveness of techniques and materials used to restore anterior primary teeth. The aim of this dissertation is to explore some of the aspects related to currently restorative approaches performed in anterior primary teeth. This is a retrospective study (historical cohorts), based on data from dental records of children (from 3 to 6 years old) with anterior teeth restored as part of complete dental care, received in some clinical trials for investigating other purposes. Data related to the restorative procedures, socioeconomic characteristics and quality of life (related to oral health) were collected from these records, from the baseline and follow-ups. The present study will be divided in three chapters. In the first chapter we describe the real prevalence of restorative needs for primary anterior teeth in a sample of children looking for treatment and the impact of these needs on children\'s quality of life. In the second chapter, the success rate of restorations performed on anterior teeth, under relative Isolation technique, both with Composite Resin (CR) and resin modified glass ionomer cement (RMGIC) was evaluated and risk factors for the occurrence of failures were investigated. In the third chapter, an economic analysis was performed in order to verify if the RMGIC could be an economically feasible alternative to the CR, under the described circumstances. Our findings suggest the need of restorations in primary anterior teeth is not very high; however, it is associated with a negative impact on the children\'s quality of life. Children whose anterior teeth, need to be restored, are those with higher caries experience. Restorations involving proximal surfaces required more reinterventions. When adhesive restorations are performed on anterior teeth, under relative isolation, those restorations performed with CR present a greater need for reinterventions (failures). Due to that, in a long-term analysis, CR restorations become as expensive as RMGIC restorations. The children`s quality of life is improved when anterior teeth are restored despite the restorative material used, but the need of reinterventions worsened children`s quality of life. Besides, the incremental cost of placing RMGIC is low and is compensated by its superiority compared to CR. In conclusion, to restore primary anterior teeth under relative isolation, the RMGIC represents a more efficacious and efficient alternative to the CR.

Page generated in 0.0587 seconds