• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 8
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Developing Novel Antibacterial Dental Filling Composite Restoratives

Caneli, Gulsah 05 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / A novel antimicrobial dental composite system has been developed and evaluated. Both alumina and zirconia filler particles were covalently coated with an antibacterial resin and blended into a composite formulation, respectively. Surface hardness and bacterial viability were used to evaluate the coated alumina fi ller-modif ed composite. Compressive strength and bacterial viability were used to evaluate the coated zirconia ller-modi ed composite. Commercial composite Kerr was used as control. The specimens were conditioned in distilled water at 37 °C for 24 h prior to testing. Four bacterial species Streptococcus mutans, Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli were used to assess the bacterial viability. Effects of antibacterial moiety content, modif ed particle size and loading, and total fi ller content was investigated. Chapter 2 describes how we studied and evaluated the composite modi fed with antibacterial resin-coated alumina llers. The results showed that almost all the modi ed composites exhibited higher antibacterial activity along with improved surface hardness, as compared to unmodi fed one. Increasing antibacterial moiety content, particle size and loading, and total fi ller content generally increased surface hardness. Increasing antibacterial moiety, fi ller loading, and total fi ller content increased antibacterial activity. On the other hand, increasing particle size showed a negative impact on antibacterial activity. The leaching tests indicate that the modiChapter 3 describes how we studied and evaluated the composite modif ed with antibacterial resin-coated zirconia fi ller. The results showed that almost all the modif ed composites exhibited higher antibacterial activity along with decreased compressive strength, as compared to the unmodif ed control. It was found that with increasing antibacterial moiety content and modi fedfi ller loading, yield strength, modulus and compressive strength of the composite were decreased. In addition, the strengths of the composite were increased with increasing powder/liquid ratio. On the other hand, with increasing antibacterial moiety content, fi ller loading and powder/liquid ratio, antibacterial activity was enhanced. In summary, we have developed a novel antibacterial dental composite system for improved dental restoratives. Both composites modif ed with the antibacterial resin-coated alumina and zirconia fi ller have demonstrated signi cant antibacterial activities. The composite modi fed with the alumina fi ller showed improved hardness values, but the composite modif ed with the zirconia fi ller showed decreased compressive strength values. It appears that the developed system is a non-leaching antibacterial dental composite. ed experimental composite showed no leachable antibacterial component to bacteria.
2

Microleakage and marginal adaptation of ultrasonically cured glass-ionomer sandwich restorations

Fourie, Jeanine 10 November 2009 (has links)
Resin based composite is currently one of the most popular dental restoratives. Used as a direct restorative material, it displays many beneficial properties such as excellent micromechanical bonding to enamel, polishability and aesthetics. Despite many advances in dentine bonding agents, dentine bonding remains problematic with microleakage and recurrent caries, being frequent clinical sequelae. The open sandwich technique was developed to overcome two problems: deficient bonding of resin composites to dentine, and inadequate strength and fracture toughness of conventional glass-ionomers (GI). GI displayed excellent cavity sealing abilities by virtue of their chemical adhesion to tooth structure. Resin-modified glass-ionomers (RMGI) were developed to improve on the weaknesses of conventional GI during early setting i.e. setting rate, water sensitivity and strength. Recently literature has reported the use of ultrasonic activation to set conventional GI, opening the possibility of improving the initial properties of the material and suitability for use in the open sandwich technique. The aim of this study was to compare microleakage of Ketac Molar, Ketac Molar set by ultrasound (US), Vitremer and Ketac N100 used in the open sandwich technique, with the control of a resin based composite, Filtek Z250. Two hundred Class II cavities were prepared in a hundred caries free, human, molar teeth, with half of the cervical margins placed apical and the rest coronal to the cemento-enamel junction. For each material, twenty restorations were placed for each cervical position. The sandwich materials were placed to fill the interproximal box level with the pulpal floor, and a final two layers of resin composite was then placed to complete the restoration. Restored teeth were stored in a laboratory oven for 7 days at 37 °C; margins were then finished initially with a medium grit Sof-Lex disc and finally with a fine diamond drill. Material groups were separated into two halfs to commence microleakage testing or thermocycling. Thermocycling was conducted for 500 cycles between 5 °C and 55 °C, with a dwell time of 30 seconds. Restored teeth were then covered with nail varnish around the restoration margins, and immersed in 0.5% basic fuchsin solution for 24 hours. They were then cleaned, embedded in clear self-curing acrylic and sectioned 3 times with an Accutom-2 precision saw, at 2 mm intervals. Sections were evaluated using a light microscope under 4 time’s magnification and microleakage scores given as: 0 = no leakage; 1 = < ½; 2 = > ½ distance to the axial wall/pulpal floor; 3 = leakage up to axial wall/pulpal floor. Statistical analysis was undertaken using Analysis of Variance (ANOVA) for the cervical and occlusal microleakage scores; p-values <0.05 were considered significant. The cervical microleakage results of cavity margins in dentine showed that Ketac Molar (US) performed better than Ketac Molar, and Ketac N100 performed better than Vitremer. Results in enamel showed no significant differences. The use of the open sandwich technique effectively reduced microleakage of cervical cavity margins placed in dentine but failed to reduce occlusal microleakage of Filtek Z250. Copyright / Dissertation (MSc(Odont))--University of Pretoria, 2008. / Odontology / unrestricted
3

Developing novel antibacterial dental filling composite restoratives

Gulsah Caneli (8726685) 29 April 2020 (has links)
A novel antimicrobial dental composite system has been developed and evaluated.Both alumina and zirconia filler particles were covalently coated with an antibacterial resin and blended into a composite formulation, respectively. Surface hardness and bacterial viability were used to evaluate the coated alumina filler-modified composite.Compressive strength and bacterial viability were used to evaluate the coated zirconia filler-modified composite. Commercial composite Kerr was used as control. The specimens were conditioned in distilled water at 37°C for 24 h prior to testing. Four bacterial species Streptococcus mutans, Staphylococcus aureus, Pseudomon asaeruginosa and Escherichia coli were used to assess the bacterial viability. Effects of antibacterial moiety content, modified particle size and loading, and total filler content were investigated.<div><br><div>Chapter 2 describes how we studied and evaluated the composite modified with antibacterial resin-coated alumina fillers. The results showed that almost all the modified composites exhibited higher antibacterial activity along with improved surface hardness, as compared to unmodified one. Increasing antibacterial moiety content, particle size and loading, and total filler content generally increased surface hardness. Increasing antibacterial moiety, filler loading, and total filler content increased antibacterial activity. On the other hand, increasing particle size showed a negative impact on antibacterial activity. The leaching tests indicate that the modified experimental composite showed no leachable antibacterial component to bacteria.<br></div><div><br></div><div>Chapter 3 describes how we studied and evaluated the composite modified with antibacterial resin-coated zirconia fillers. The results showed that almost all the modified composites exhibited higher antibacterial activity along with decreased compressive strength, as compared to the unmodified control. It was found that with increasing antibacterial moiety content and modified filler loading, yield strength,modulus and compressive strength of the composite were decreased. In addition,the strengths of the composite were increased with increasing powder/liquid ratio.On the other hand, with increasing antibacterial moiety content, filler loading and powder/liquid ratio, antibacterial activity was enhanced.<br></div><div><br></div><div>In summary, we have developed a novel antibacterial dental composite system for improved dental restoratives. Both composites modified with the antibacterial resin-coated alumina and zirconia fillers have demonstrated significant antibacterial activities.The composite modified with the alumina fillers showed improved hardness values, but the composite modified with the zirconia fillers showed decreased compressive strength values. It appears that the developed system is a non-leaching antibacterial dental composite.<br></div></div>
4

Capacidade de detecção de adulteração e suficiência das provas oficiais para assegurar a qualidade do leite pasteurizado / Ability to detect adulteration and sufficiency of the official tests to assure pasteurized milk quality

Silva, Lívia Cavaletti Correa da January 2013 (has links)
O leite é um alimento sujeito à fraudes. As mais frequentes são a adição de água, reconstituintes, conservantes e neutralizantes. Apesar da legislação determinar a pesquisa diária dessas substâncias, a avaliação do leite pelas indústrias geralmente é realizada apenas por análises físico-químicas genéricas como densidade e crioscopia. Contudo, essas fraudes muitas vezes são calculadas para impedir sua identificação por provas de rotina não específicas. O objetivo desse trabalho foi pesquisar a ocorrência de fraudes, resíduos de antibióticos e irregularidades físico-químicas e microbiológicas em leite pasteurizado, bem como avaliar a capacidade de detecção de adulterações e a suficiência das provas oficiais específicas e inespecíficas na identificação da adição de reconstituintes, conservantes e neutralizantes. Foram avaliadas 100 amostras de leite pasteurizado, produzido no Paraná, para a presença de reconstituintes, conservantes, neutralizantes e antibióticos e demais parâmetros físico-químicos e microbiológicos determinados pela legislação. Em outro experimento, a capacidade de detecção das provas oficiais para pesquisa de sacarose, cloretos, amido, formaldeído, cloro, hipoclorito, peróxido de hidrogênio e neutralizantes da acidez foi avaliada utilizando-se de amostras adulteradas em laboratório. Foram avaliados adicionalmente testes não oficiais para avaliar a presença de inibidores do crescimento microbiano e o efeito inibidor de algumas substâncias conservantes e neutralizantes sobre a microbiota do leite cru. Os resultados mostraram que das 100 amostras de leite pasteurizado, 51% apresentaram problemas, das quais 25% estavam fora dos padrões nas análises físico-químicas e 10% nas análises microbiológicas, 14% apresentaram resíduos de antibióticos e a adição de reconstituintes foi detectada em 13% das amostras. Observou-se que a avaliação do leite apenas por análises físico-químicas de rotina, como densidade e crioscopia não é suficiente para identificar fraudes por adição de água e reconstituintes. As provas para a pesquisa específica de substâncias reconstituintes apresentaram boa capacidade de detecção, assim como a prova para pesquisa de formaldeído. A adição de sacarose em amostras adulteradas no laboratório elevou a porcentagem de lactose detectada por equipamentos que utilizam infravermelho e ultrassom, demonstrando que estes equipamentos não quantificam especificamente a lactose. Quanto às amostras adicionadas de conservantes e neutralizantes no laboratório, a prova inespecífica da cultura de iogurte foi capaz de detectar a inibição de crescimento nas amostras adicionadas de formaldeído, peróxido de hidrogênio, hipoclorito e hidróxido de sódio, apresentando resultados próximos aos das provas oficiais para a pesquisa dessas substâncias. A adição de formaldeído, peróxido de hidrogênio e hipoclorito promoveu reduções significativas nas contagens de micro-organismos aeróbios mesófilos no leite cru adulterado no laboratório. o entanto, não foi possível detectar peróxido de hidrogênio e compostos clorados após 24 horas de refrigeração, provavelmente em consequência da degradação e /ou inativação dessas substâncias no leite. A prova para a pesquisa de neutralizantes da acidez detecta a substância apenas quando a alcalinização é excessiva. A neutralização equilibrada do ácido lático resulta na anulação da capacidade de detecção da prova. A pesquisa de inibidores microbianos, neutralizantes e reconstituintes é obrigatória apenas para leite cru, porém, a presença de grande parcela de amostras positivas para reconstituintes e antimicrobianos no leite pasteurizado demonstra falhas no controle de qualidade e pode indicar a prática de adulteração do leite também pela indústria. / Milk is one of the major targets for fraud. The most frequent are addition of water, restoratives, preservatives and neutralizers. Although legislation determines the daily survey of these substances by specific tests, milk evaluation by industries is usually performed only by generic physicochemical tests as density and freezing point. However, these adulterations are often calculated to prevent their identification by these routine non specific tests. The aim of this study was to investigate the occurrence of fraud, antibiotic residues and irregularities in physico-chemical and microbiological parameters in pasteurized milk produced in northern Paraná, as well as to evaluate the ability of adulteration detection by official tests to identify the addition of restoratives, preservatives and neutralizers in milk. An assessement was performed in 100 pasteurized milk samples to evaluate the presence of restoratives, preservatives, antibiotics and neutralizers and other physico-chemical and microbiological tests determined by legislation. In a second experiment, the detection ability of official tests for the research of sucrose, chloride, starch, formaldehyde, chlorine, hypochlorite, hydrogen peroxide and neutralizers was evaluated using samples adultered in laboratory. Additionally, unofficial tests to evaluate the presence of inhibitors of microbial growth and the inhibitory effect of some preservative and neutralizers substances on the biota of raw milk were performed. Results show that of the 100 samples of pasteurized milk evaluated, 51% had problems, from which 25% were outside parameters for physicochemical analyzes, 10% for microbiological analyzes, 14% were positive for the presence of antibiotic and in 13% adulteration by restoratives were detected. It was observed that milk evaluation only by physico-chemical routine analyzes, such as density and cryoscopy is not sufficient to identify fraud by water and restoratives addition. Specific tets for restoratives detection exhibit good detection potentials, as well as the test for formaldehyde. . The addition of sugar altered quantification of lactose detected by equipments tha use infrared and ultrasound, demonstrating that these do not detect lactose exclusively. Regarding samples added with preservatives and neutralizers substances in laboratory, the yogurt culture test was able to detect microbial grouth inhibition in samples added with formaldehyde, hydrogen peroxide, hypochlorite and sodium hydroxide. Presenting resluts similar to the official tests. The addition of formaldehyde, hydrogen peroxide and hypochlorite promoted significant reductions in the counts of mesophilic aerobic micro-organisms in raw milk adulterated in laboratory. However it was not possible to detect hydrogen peroxide and clhorated compounds after 24 hours of refrigeration, maybe due to its rapid degradation and / or inactivation of these substances in milk. Neutralizing substances detection can only dectect this substances when alcalinization is excessive. The balanced neutralization of latic acid results on the anulment of detection ability of the test. The research of preservatives, neutralizers and restoratives is not required for pasteurized milk, only for raw milk. The presence of large numbers of samples positive for these substances demonstrates flaws in quality control of raw milk or occurrence of milk adulteration by the industry itself.
5

Capacidade de detecção de adulteração e suficiência das provas oficiais para assegurar a qualidade do leite pasteurizado / Ability to detect adulteration and sufficiency of the official tests to assure pasteurized milk quality

Silva, Lívia Cavaletti Correa da January 2013 (has links)
O leite é um alimento sujeito à fraudes. As mais frequentes são a adição de água, reconstituintes, conservantes e neutralizantes. Apesar da legislação determinar a pesquisa diária dessas substâncias, a avaliação do leite pelas indústrias geralmente é realizada apenas por análises físico-químicas genéricas como densidade e crioscopia. Contudo, essas fraudes muitas vezes são calculadas para impedir sua identificação por provas de rotina não específicas. O objetivo desse trabalho foi pesquisar a ocorrência de fraudes, resíduos de antibióticos e irregularidades físico-químicas e microbiológicas em leite pasteurizado, bem como avaliar a capacidade de detecção de adulterações e a suficiência das provas oficiais específicas e inespecíficas na identificação da adição de reconstituintes, conservantes e neutralizantes. Foram avaliadas 100 amostras de leite pasteurizado, produzido no Paraná, para a presença de reconstituintes, conservantes, neutralizantes e antibióticos e demais parâmetros físico-químicos e microbiológicos determinados pela legislação. Em outro experimento, a capacidade de detecção das provas oficiais para pesquisa de sacarose, cloretos, amido, formaldeído, cloro, hipoclorito, peróxido de hidrogênio e neutralizantes da acidez foi avaliada utilizando-se de amostras adulteradas em laboratório. Foram avaliados adicionalmente testes não oficiais para avaliar a presença de inibidores do crescimento microbiano e o efeito inibidor de algumas substâncias conservantes e neutralizantes sobre a microbiota do leite cru. Os resultados mostraram que das 100 amostras de leite pasteurizado, 51% apresentaram problemas, das quais 25% estavam fora dos padrões nas análises físico-químicas e 10% nas análises microbiológicas, 14% apresentaram resíduos de antibióticos e a adição de reconstituintes foi detectada em 13% das amostras. Observou-se que a avaliação do leite apenas por análises físico-químicas de rotina, como densidade e crioscopia não é suficiente para identificar fraudes por adição de água e reconstituintes. As provas para a pesquisa específica de substâncias reconstituintes apresentaram boa capacidade de detecção, assim como a prova para pesquisa de formaldeído. A adição de sacarose em amostras adulteradas no laboratório elevou a porcentagem de lactose detectada por equipamentos que utilizam infravermelho e ultrassom, demonstrando que estes equipamentos não quantificam especificamente a lactose. Quanto às amostras adicionadas de conservantes e neutralizantes no laboratório, a prova inespecífica da cultura de iogurte foi capaz de detectar a inibição de crescimento nas amostras adicionadas de formaldeído, peróxido de hidrogênio, hipoclorito e hidróxido de sódio, apresentando resultados próximos aos das provas oficiais para a pesquisa dessas substâncias. A adição de formaldeído, peróxido de hidrogênio e hipoclorito promoveu reduções significativas nas contagens de micro-organismos aeróbios mesófilos no leite cru adulterado no laboratório. o entanto, não foi possível detectar peróxido de hidrogênio e compostos clorados após 24 horas de refrigeração, provavelmente em consequência da degradação e /ou inativação dessas substâncias no leite. A prova para a pesquisa de neutralizantes da acidez detecta a substância apenas quando a alcalinização é excessiva. A neutralização equilibrada do ácido lático resulta na anulação da capacidade de detecção da prova. A pesquisa de inibidores microbianos, neutralizantes e reconstituintes é obrigatória apenas para leite cru, porém, a presença de grande parcela de amostras positivas para reconstituintes e antimicrobianos no leite pasteurizado demonstra falhas no controle de qualidade e pode indicar a prática de adulteração do leite também pela indústria. / Milk is one of the major targets for fraud. The most frequent are addition of water, restoratives, preservatives and neutralizers. Although legislation determines the daily survey of these substances by specific tests, milk evaluation by industries is usually performed only by generic physicochemical tests as density and freezing point. However, these adulterations are often calculated to prevent their identification by these routine non specific tests. The aim of this study was to investigate the occurrence of fraud, antibiotic residues and irregularities in physico-chemical and microbiological parameters in pasteurized milk produced in northern Paraná, as well as to evaluate the ability of adulteration detection by official tests to identify the addition of restoratives, preservatives and neutralizers in milk. An assessement was performed in 100 pasteurized milk samples to evaluate the presence of restoratives, preservatives, antibiotics and neutralizers and other physico-chemical and microbiological tests determined by legislation. In a second experiment, the detection ability of official tests for the research of sucrose, chloride, starch, formaldehyde, chlorine, hypochlorite, hydrogen peroxide and neutralizers was evaluated using samples adultered in laboratory. Additionally, unofficial tests to evaluate the presence of inhibitors of microbial growth and the inhibitory effect of some preservative and neutralizers substances on the biota of raw milk were performed. Results show that of the 100 samples of pasteurized milk evaluated, 51% had problems, from which 25% were outside parameters for physicochemical analyzes, 10% for microbiological analyzes, 14% were positive for the presence of antibiotic and in 13% adulteration by restoratives were detected. It was observed that milk evaluation only by physico-chemical routine analyzes, such as density and cryoscopy is not sufficient to identify fraud by water and restoratives addition. Specific tets for restoratives detection exhibit good detection potentials, as well as the test for formaldehyde. . The addition of sugar altered quantification of lactose detected by equipments tha use infrared and ultrasound, demonstrating that these do not detect lactose exclusively. Regarding samples added with preservatives and neutralizers substances in laboratory, the yogurt culture test was able to detect microbial grouth inhibition in samples added with formaldehyde, hydrogen peroxide, hypochlorite and sodium hydroxide. Presenting resluts similar to the official tests. The addition of formaldehyde, hydrogen peroxide and hypochlorite promoted significant reductions in the counts of mesophilic aerobic micro-organisms in raw milk adulterated in laboratory. However it was not possible to detect hydrogen peroxide and clhorated compounds after 24 hours of refrigeration, maybe due to its rapid degradation and / or inactivation of these substances in milk. Neutralizing substances detection can only dectect this substances when alcalinization is excessive. The balanced neutralization of latic acid results on the anulment of detection ability of the test. The research of preservatives, neutralizers and restoratives is not required for pasteurized milk, only for raw milk. The presence of large numbers of samples positive for these substances demonstrates flaws in quality control of raw milk or occurrence of milk adulteration by the industry itself.
6

Capacidade de detecção de adulteração e suficiência das provas oficiais para assegurar a qualidade do leite pasteurizado / Ability to detect adulteration and sufficiency of the official tests to assure pasteurized milk quality

Silva, Lívia Cavaletti Correa da January 2013 (has links)
O leite é um alimento sujeito à fraudes. As mais frequentes são a adição de água, reconstituintes, conservantes e neutralizantes. Apesar da legislação determinar a pesquisa diária dessas substâncias, a avaliação do leite pelas indústrias geralmente é realizada apenas por análises físico-químicas genéricas como densidade e crioscopia. Contudo, essas fraudes muitas vezes são calculadas para impedir sua identificação por provas de rotina não específicas. O objetivo desse trabalho foi pesquisar a ocorrência de fraudes, resíduos de antibióticos e irregularidades físico-químicas e microbiológicas em leite pasteurizado, bem como avaliar a capacidade de detecção de adulterações e a suficiência das provas oficiais específicas e inespecíficas na identificação da adição de reconstituintes, conservantes e neutralizantes. Foram avaliadas 100 amostras de leite pasteurizado, produzido no Paraná, para a presença de reconstituintes, conservantes, neutralizantes e antibióticos e demais parâmetros físico-químicos e microbiológicos determinados pela legislação. Em outro experimento, a capacidade de detecção das provas oficiais para pesquisa de sacarose, cloretos, amido, formaldeído, cloro, hipoclorito, peróxido de hidrogênio e neutralizantes da acidez foi avaliada utilizando-se de amostras adulteradas em laboratório. Foram avaliados adicionalmente testes não oficiais para avaliar a presença de inibidores do crescimento microbiano e o efeito inibidor de algumas substâncias conservantes e neutralizantes sobre a microbiota do leite cru. Os resultados mostraram que das 100 amostras de leite pasteurizado, 51% apresentaram problemas, das quais 25% estavam fora dos padrões nas análises físico-químicas e 10% nas análises microbiológicas, 14% apresentaram resíduos de antibióticos e a adição de reconstituintes foi detectada em 13% das amostras. Observou-se que a avaliação do leite apenas por análises físico-químicas de rotina, como densidade e crioscopia não é suficiente para identificar fraudes por adição de água e reconstituintes. As provas para a pesquisa específica de substâncias reconstituintes apresentaram boa capacidade de detecção, assim como a prova para pesquisa de formaldeído. A adição de sacarose em amostras adulteradas no laboratório elevou a porcentagem de lactose detectada por equipamentos que utilizam infravermelho e ultrassom, demonstrando que estes equipamentos não quantificam especificamente a lactose. Quanto às amostras adicionadas de conservantes e neutralizantes no laboratório, a prova inespecífica da cultura de iogurte foi capaz de detectar a inibição de crescimento nas amostras adicionadas de formaldeído, peróxido de hidrogênio, hipoclorito e hidróxido de sódio, apresentando resultados próximos aos das provas oficiais para a pesquisa dessas substâncias. A adição de formaldeído, peróxido de hidrogênio e hipoclorito promoveu reduções significativas nas contagens de micro-organismos aeróbios mesófilos no leite cru adulterado no laboratório. o entanto, não foi possível detectar peróxido de hidrogênio e compostos clorados após 24 horas de refrigeração, provavelmente em consequência da degradação e /ou inativação dessas substâncias no leite. A prova para a pesquisa de neutralizantes da acidez detecta a substância apenas quando a alcalinização é excessiva. A neutralização equilibrada do ácido lático resulta na anulação da capacidade de detecção da prova. A pesquisa de inibidores microbianos, neutralizantes e reconstituintes é obrigatória apenas para leite cru, porém, a presença de grande parcela de amostras positivas para reconstituintes e antimicrobianos no leite pasteurizado demonstra falhas no controle de qualidade e pode indicar a prática de adulteração do leite também pela indústria. / Milk is one of the major targets for fraud. The most frequent are addition of water, restoratives, preservatives and neutralizers. Although legislation determines the daily survey of these substances by specific tests, milk evaluation by industries is usually performed only by generic physicochemical tests as density and freezing point. However, these adulterations are often calculated to prevent their identification by these routine non specific tests. The aim of this study was to investigate the occurrence of fraud, antibiotic residues and irregularities in physico-chemical and microbiological parameters in pasteurized milk produced in northern Paraná, as well as to evaluate the ability of adulteration detection by official tests to identify the addition of restoratives, preservatives and neutralizers in milk. An assessement was performed in 100 pasteurized milk samples to evaluate the presence of restoratives, preservatives, antibiotics and neutralizers and other physico-chemical and microbiological tests determined by legislation. In a second experiment, the detection ability of official tests for the research of sucrose, chloride, starch, formaldehyde, chlorine, hypochlorite, hydrogen peroxide and neutralizers was evaluated using samples adultered in laboratory. Additionally, unofficial tests to evaluate the presence of inhibitors of microbial growth and the inhibitory effect of some preservative and neutralizers substances on the biota of raw milk were performed. Results show that of the 100 samples of pasteurized milk evaluated, 51% had problems, from which 25% were outside parameters for physicochemical analyzes, 10% for microbiological analyzes, 14% were positive for the presence of antibiotic and in 13% adulteration by restoratives were detected. It was observed that milk evaluation only by physico-chemical routine analyzes, such as density and cryoscopy is not sufficient to identify fraud by water and restoratives addition. Specific tets for restoratives detection exhibit good detection potentials, as well as the test for formaldehyde. . The addition of sugar altered quantification of lactose detected by equipments tha use infrared and ultrasound, demonstrating that these do not detect lactose exclusively. Regarding samples added with preservatives and neutralizers substances in laboratory, the yogurt culture test was able to detect microbial grouth inhibition in samples added with formaldehyde, hydrogen peroxide, hypochlorite and sodium hydroxide. Presenting resluts similar to the official tests. The addition of formaldehyde, hydrogen peroxide and hypochlorite promoted significant reductions in the counts of mesophilic aerobic micro-organisms in raw milk adulterated in laboratory. However it was not possible to detect hydrogen peroxide and clhorated compounds after 24 hours of refrigeration, maybe due to its rapid degradation and / or inactivation of these substances in milk. Neutralizing substances detection can only dectect this substances when alcalinization is excessive. The balanced neutralization of latic acid results on the anulment of detection ability of the test. The research of preservatives, neutralizers and restoratives is not required for pasteurized milk, only for raw milk. The presence of large numbers of samples positive for these substances demonstrates flaws in quality control of raw milk or occurrence of milk adulteration by the industry itself.
7

Avaliação do efeito de diferentes concentrações de fotoiniciadores em propriedades mecânicas e na cor de um adesivo dental experimental / Effect of Different Photoinitiators Concentration on the Mechanical Properties and Shade of an Experimental Dental Adhesive

Faleiros, Daniel Elias de Melo 13 April 2016 (has links)
O presente trabalho teve por foco prover uma revisão de conceitos relacionados às resinas dentais fotopolimeráveis e, também, analisar como diferentes concentrações de fotoiniciadores de uso comum em odontologia podem influenciar no desempenho mecânico e na cor de resinas dentais. Concentrações de 0,01%, 0,10%, 0,25% 0,50%, 0,75%, 1,00% e 10% em massa de fotoiniciador foram adicionadas em uma matriz polimérica composta por TEGDMA/BisGMA 50%/50% em massa de forma que, fixando variáveis externas referentes à fonte de luz e à preparação das amostras, foi possível avaliar o efeito da concentração de fotoiniciador nas propriedades mecânicas de resistência à fratura por compressão, resistência à fratura pela aplicação de tensão diametral e dureza Barcol. Por fim, o efeito da concentração na cor aferida através do método CIELab foi investigada. Os fotoiniciadores utilizados foram o Irgacure® 819, a 1-fenil-1,2-propanodiona (PPD) e a Canforoquinona a qual foi utilizada juntamente com ocoiniciador Etil-4 dimetilaminobenzoato (EDB) na concentração constante de 1% em massa. Os resultados mecânicos e de cor foram comparados entre as diferentes amostras através de análises estatísticas (ANOVA) e, especificamente para cor, o parâmetro de diferença de cor (&Delta;E) foi interpretado verificar se as alterações observadas são perceptíveis ao olho humano. Para fundamentar os estudos, análises do espectro de absorção das amostras, do espectro de irradiação da fonte de luz e do grau de conversão das amostras foram realizadas. Os resultados revelaram que, independentemente do fotoiniciador, graus de conversão da mesma ordem de grandeza de um adesivo comercial foram obtidos, porém as velocidades de reação foram diferentes (maior velocidade para as amostras de CQ e menor para PPD). Curvas características foram obtidas para os espectros de absorção e de irradiação confirmando, pela sobreposição das curvas, que a fonte de luz é efetiva para iniciação da polimerização das amostras. As análises de resistência à fratura revelaram que a quebra catastrófica do material ocorrerá preferencialmente quando a força é aplicada ao longo do diâmetro para os corpos de prova preparados. Quanto à dureza, verificou-se que que para a CQ houve um máximo, para Irgacure um comportamento assintótico com aumento da concentração e, para a PPD, não foi possível a obtenção de amostras (verificado que a PPD necessita de tempo de irradiação superior ao convencionalmente utilizado na prática odontológica). Os testes de ANOVA permitiram verificar que o Irgacure é capaz de fornecer resultados mecânicos semelhante em relação à CQ ocasionando, em contrapartida, um menor escurecimento e amarelamento. Analisando o parâmetro &Delta;E, confirmou-se que a alteração na cor se torna evidente à medida que ocorre o aumento da concentração de fotoiniciador independentemente do fotoiniciador utilizado, porém a alteração é maior para a CQ. / The focused of the present work was conduct a concept review of the photochemical dental restoratives (resins) state-of-art and, also, evaluate the influence of photoinitiator concentration in mechanical behavior and shade. Different quantities of photoinitiators (0,01%, 0,10%, 0,25%, 0,50%, 0,75%, 1,00% and 10% wt.) were added in a resin based prepared of TEGDMA/BisGMA (50%/50% wt./wt.) to inspect the effect of the photoinitiator load in the diametral tensile strength (DTS), compressive strength (CS), Barcol hardness and, also, in the color perception measured by CIELab test method. The photoinitiatorsused were the Irgacure. 819, the Phenil-propanodione (PPD) and the Camphoroquinone (CPQ), which was used with EDB (1% in weigh) as a coinitiator. The mechanical properties were compared between the different concentrations and photoinitiators using ANOVA statistical analysis. For color, the different samples was compared using the parameter &Delta;E. Finally, the absorption spectrum and the degree of conversion for each concentration was obtained to support the experimental tests. Results showed that, independently of the photoinitiator used, degrees of conversion similar with a commercial adhesive were obtained, but the polymerization rate were different (higher for the CPQ samples and lower for PPD). The absorption spectra of samples were obtained and the overlap with the 3M ESPE LED irradiation curve confirmed the effectiveness of the light source to promote the initiation of the polymerization process. Mechanical results analysis showed that the catastrophic breakdown of the material occurs preferentially when the force is applied along the diameter (DST tests) in the prepared specimens. Regarding hardness, different behavior could be perceived: i) a curve with a maximum point occur for CPQ, ii) for Irgacure. 819 an asymptotic curve was obtained with the photoinitiatorconcentration growth and, finally, iii) no curve was obtained for PPD once for PPD it was realized that is required an irradiation time higher than the conventional 20s used in the clinical interventions and, also, higher than the methodology used in the present work. ANOVA tests showed that Irgacure. 819 samples could provide similar mechanical performance compared CPQ but, on the other hand, lower color variation with the concentration growth. The parameter &Delta;E confirmed that the color change becomes more noticeable as an increase in photoinitiator concentration occurs regardless of photoinitiator used, but the color variation is much higher in CQ compared with the other systems.
8

Avaliação do efeito de diferentes concentrações de fotoiniciadores em propriedades mecânicas e na cor de um adesivo dental experimental / Effect of Different Photoinitiators Concentration on the Mechanical Properties and Shade of an Experimental Dental Adhesive

Daniel Elias de Melo Faleiros 13 April 2016 (has links)
O presente trabalho teve por foco prover uma revisão de conceitos relacionados às resinas dentais fotopolimeráveis e, também, analisar como diferentes concentrações de fotoiniciadores de uso comum em odontologia podem influenciar no desempenho mecânico e na cor de resinas dentais. Concentrações de 0,01%, 0,10%, 0,25% 0,50%, 0,75%, 1,00% e 10% em massa de fotoiniciador foram adicionadas em uma matriz polimérica composta por TEGDMA/BisGMA 50%/50% em massa de forma que, fixando variáveis externas referentes à fonte de luz e à preparação das amostras, foi possível avaliar o efeito da concentração de fotoiniciador nas propriedades mecânicas de resistência à fratura por compressão, resistência à fratura pela aplicação de tensão diametral e dureza Barcol. Por fim, o efeito da concentração na cor aferida através do método CIELab foi investigada. Os fotoiniciadores utilizados foram o Irgacure® 819, a 1-fenil-1,2-propanodiona (PPD) e a Canforoquinona a qual foi utilizada juntamente com ocoiniciador Etil-4 dimetilaminobenzoato (EDB) na concentração constante de 1% em massa. Os resultados mecânicos e de cor foram comparados entre as diferentes amostras através de análises estatísticas (ANOVA) e, especificamente para cor, o parâmetro de diferença de cor (&Delta;E) foi interpretado verificar se as alterações observadas são perceptíveis ao olho humano. Para fundamentar os estudos, análises do espectro de absorção das amostras, do espectro de irradiação da fonte de luz e do grau de conversão das amostras foram realizadas. Os resultados revelaram que, independentemente do fotoiniciador, graus de conversão da mesma ordem de grandeza de um adesivo comercial foram obtidos, porém as velocidades de reação foram diferentes (maior velocidade para as amostras de CQ e menor para PPD). Curvas características foram obtidas para os espectros de absorção e de irradiação confirmando, pela sobreposição das curvas, que a fonte de luz é efetiva para iniciação da polimerização das amostras. As análises de resistência à fratura revelaram que a quebra catastrófica do material ocorrerá preferencialmente quando a força é aplicada ao longo do diâmetro para os corpos de prova preparados. Quanto à dureza, verificou-se que que para a CQ houve um máximo, para Irgacure um comportamento assintótico com aumento da concentração e, para a PPD, não foi possível a obtenção de amostras (verificado que a PPD necessita de tempo de irradiação superior ao convencionalmente utilizado na prática odontológica). Os testes de ANOVA permitiram verificar que o Irgacure é capaz de fornecer resultados mecânicos semelhante em relação à CQ ocasionando, em contrapartida, um menor escurecimento e amarelamento. Analisando o parâmetro &Delta;E, confirmou-se que a alteração na cor se torna evidente à medida que ocorre o aumento da concentração de fotoiniciador independentemente do fotoiniciador utilizado, porém a alteração é maior para a CQ. / The focused of the present work was conduct a concept review of the photochemical dental restoratives (resins) state-of-art and, also, evaluate the influence of photoinitiator concentration in mechanical behavior and shade. Different quantities of photoinitiators (0,01%, 0,10%, 0,25%, 0,50%, 0,75%, 1,00% and 10% wt.) were added in a resin based prepared of TEGDMA/BisGMA (50%/50% wt./wt.) to inspect the effect of the photoinitiator load in the diametral tensile strength (DTS), compressive strength (CS), Barcol hardness and, also, in the color perception measured by CIELab test method. The photoinitiatorsused were the Irgacure. 819, the Phenil-propanodione (PPD) and the Camphoroquinone (CPQ), which was used with EDB (1% in weigh) as a coinitiator. The mechanical properties were compared between the different concentrations and photoinitiators using ANOVA statistical analysis. For color, the different samples was compared using the parameter &Delta;E. Finally, the absorption spectrum and the degree of conversion for each concentration was obtained to support the experimental tests. Results showed that, independently of the photoinitiator used, degrees of conversion similar with a commercial adhesive were obtained, but the polymerization rate were different (higher for the CPQ samples and lower for PPD). The absorption spectra of samples were obtained and the overlap with the 3M ESPE LED irradiation curve confirmed the effectiveness of the light source to promote the initiation of the polymerization process. Mechanical results analysis showed that the catastrophic breakdown of the material occurs preferentially when the force is applied along the diameter (DST tests) in the prepared specimens. Regarding hardness, different behavior could be perceived: i) a curve with a maximum point occur for CPQ, ii) for Irgacure. 819 an asymptotic curve was obtained with the photoinitiatorconcentration growth and, finally, iii) no curve was obtained for PPD once for PPD it was realized that is required an irradiation time higher than the conventional 20s used in the clinical interventions and, also, higher than the methodology used in the present work. ANOVA tests showed that Irgacure. 819 samples could provide similar mechanical performance compared CPQ but, on the other hand, lower color variation with the concentration growth. The parameter &Delta;E confirmed that the color change becomes more noticeable as an increase in photoinitiator concentration occurs regardless of photoinitiator used, but the color variation is much higher in CQ compared with the other systems.

Page generated in 0.089 seconds