• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 15
  • 11
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 105
  • 105
  • 39
  • 37
  • 28
  • 21
  • 20
  • 16
  • 14
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Ultraschall-basierte Elastographie bei dekompensierter Leberzirrhose zur Charakterisierung und Prognosebewertung bei Patienten mit Indikation zur Anlage eines transjugulären intrahepatischen portosystemischen Shunts (TIPS)

Gnatzy, Franziska 05 March 2021 (has links)
No description available.
92

Synthesizing of brain MRE wave data / Syntetistering av vågrörelsedata för hjärnan med MRE

Yuliuhina, Maryia January 2023 (has links)
Magnetic resonance elastography (MRE) is an imaging technique that allows for non-invasive access to the physical properties of body tissues. MRE has great potential, but it is difficult to conduct research due to the time-consuming estimation of stiffness maps, which could be speeded up by using neural network. However, there is not enough real data to train one, thus, synthetic data is needed. To create synthetic data three techniques of simulating tissue displacement due to wave propagation was explored, including solving differential equations for a system of coupled harmonic oscillators (CHO method) and using two different functions from the k-Wave toolbox. Each of the three methods demonstrated the ability to replicate the displacement pattern in a phantom with a simple structure. The CHO method and \texttt{kspaceFirstOrder} function of the k-Wave toolbox showed the best performance when simulating displacement in a 2D brain slice. The models are not very accurate, but capture general features of displacement in a brain and hold potential for future improvement. / Magnetresonans-elastografi (MRE) är en avbildningsteknik som möjliggör icke-invasiv åtkomst till de fysiska egenskaperna hos olika vävnader. MRE har stor potential, men forskning inom ämnet försvåras på grund av den tidskrävande beräkningen av elasticitetskartorna, vilket kan påskyndas med hjälp av ett neuralt nätverk. Dock finns det inte tillräckligt med experimentiell data för att träna ett sådant nätverk, och därför behövs syntetisk data. För att skapa sådan syntetisk MRE-data utforskades tre tekniker för att simulera vågrörelser i hjärnvävnad; dessa tekniker inkluderar lösning av differentialekvationer för ett system av kopplade harmoniska oscillatorer (CHO-metoden) och användning av två olika funktioner från det Matlab-baserade programmet k-Wave. Var och en av de tre metoderna visade potential att återskapa vågsmönstret i en enkel strukturerad fantom. CHO-metoden och funktionen kspaceFirstOrder från k-Wave visade bäst prestanda vid simulering av vågrörelser i ett 2D-segment av hjärnan. Modellerna visade sig inte vara särskilt precisa, men fångar allmänna, kvalitativa, egenskaper av vågrörelser i hjärnan och uppvisar potential för framtida förbättring.
93

Développement d'une nouvelle méthode de caractérisation tissulaire basée sur l'élastographie ultrasonore : application pour le dépistage précoce du cancer du sein

Ouared, Abderrahmane 09 1900 (has links)
Le cancer du sein est le cancer le plus fréquent chez la femme. Il demeure la cause de mortalité la plus importante chez les femmes âgées entre 35 et 55 ans. Au Canada, plus de 20 000 nouveaux cas sont diagnostiqués chaque année. Les études scientifiques démontrent que l'espérance de vie est étroitement liée à la précocité du diagnostic. Les moyens de diagnostic actuels comme la mammographie, l'échographie et la biopsie comportent certaines limitations. Par exemple, la mammographie permet de diagnostiquer la présence d’une masse suspecte dans le sein, mais ne peut en déterminer la nature (bénigne ou maligne). Les techniques d’imagerie complémentaires comme l'échographie ou l'imagerie par résonance magnétique (IRM) sont alors utilisées en complément, mais elles sont limitées quant à la sensibilité et la spécificité de leur diagnostic, principalement chez les jeunes femmes (< 50 ans) ou celles ayant un parenchyme dense. Par conséquent, nombreuses sont celles qui doivent subir une biopsie alors que leur lésions sont bénignes. Quelques voies de recherche sont privilégiées depuis peu pour réduire l`incertitude du diagnostic par imagerie ultrasonore. Dans ce contexte, l’élastographie dynamique est prometteuse. Cette technique est inspirée du geste médical de palpation et est basée sur la détermination de la rigidité des tissus, sachant que les lésions en général sont plus rigides que le tissu sain environnant. Le principe de cette technique est de générer des ondes de cisaillement et d'en étudier la propagation de ces ondes afin de remonter aux propriétés mécaniques du milieu via un problème inverse préétabli. Cette thèse vise le développement d'une nouvelle méthode d'élastographie dynamique pour le dépistage précoce des lésions mammaires. L'un des principaux problèmes des techniques d'élastographie dynamiques en utilisant la force de radiation est la forte atténuation des ondes de cisaillement. Après quelques longueurs d'onde de propagation, les amplitudes de déplacement diminuent considérablement et leur suivi devient difficile voir impossible. Ce problème affecte grandement la caractérisation des tissus biologiques. En outre, ces techniques ne donnent que l'information sur l'élasticité tandis que des études récentes montrent que certaines lésions bénignes ont les mêmes élasticités que des lésions malignes ce qui affecte la spécificité de ces techniques et motive la quantification de d'autres paramètres mécaniques (e.g.la viscosité). Le premier objectif de cette thèse consiste à optimiser la pression de radiation acoustique afin de rehausser l'amplitude des déplacements générés. Pour ce faire, un modèle analytique de prédiction de la fréquence de génération de la force de radiation a été développé. Une fois validé in vitro, ce modèle a servi pour la prédiction des fréquences optimales pour la génération de la force de radiation dans d'autres expérimentations in vitro et ex vivo sur des échantillons de tissu mammaire obtenus après mastectomie totale. Dans la continuité de ces travaux, un prototype de sonde ultrasonore conçu pour la génération d'un type spécifique d'ondes de cisaillement appelé ''onde de torsion'' a été développé. Le but est d'utiliser la force de radiation optimisée afin de générer des ondes de cisaillement adaptatives, et de monter leur utilité dans l'amélioration de l'amplitude des déplacements. Contrairement aux techniques élastographiques classiques, ce prototype permet la génération des ondes de cisaillement selon des parcours adaptatifs (e.g. circulaire, elliptique,…etc.) dépendamment de la forme de la lésion. L’optimisation des dépôts énergétiques induit une meilleure réponse mécanique du tissu et améliore le rapport signal sur bruit pour une meilleure quantification des paramètres viscoélastiques. Il est aussi question de consolider davantage les travaux de recherches antérieurs par un appui expérimental, et de prouver que ce type particulier d'onde de torsion peut mettre en résonance des structures. Ce phénomène de résonance des structures permet de rehausser davantage le contraste de déplacement entre les masses suspectes et le milieu environnant pour une meilleure détection. Enfin, dans le cadre de la quantification des paramètres viscoélastiques des tissus, la dernière étape consiste à développer un modèle inverse basé sur la propagation des ondes de cisaillement adaptatives pour l'estimation des paramètres viscoélastiques. L'estimation des paramètres viscoélastiques se fait via la résolution d'un problème inverse intégré dans un modèle numérique éléments finis. La robustesse de ce modèle a été étudiée afin de déterminer ces limites d'utilisation. Les résultats obtenus par ce modèle sont comparés à d'autres résultats (mêmes échantillons) obtenus par des méthodes de référence (e.g. Rheospectris) afin d'estimer la précision de la méthode développée. La quantification des paramètres mécaniques des lésions permet d'améliorer la sensibilité et la spécificité du diagnostic. La caractérisation tissulaire permet aussi une meilleure identification du type de lésion (malin ou bénin) ainsi que son évolution. Cette technique aide grandement les cliniciens dans le choix et la planification d'une prise en charge adaptée. / Breast cancer is the most frequent cancer in women and the leading cause of death for women between 35 and 55 years old. In Canada, more than 20,000 new cases are diagnosed each year. Most of the previous works have shown that life expectancy is closely related to the precocity of diagnosis. Current diagnostic imaging methods such as mammography, sonography, MRI present limitations such as irradiation (mammography), low specificity and low resolution (sonography) and high cost (MRI). For example, about 95% of abnormalities detected by mammography are proven to be benign lesions after complementary examinations (biopsy). Sonography is useful as a complementary examination but the low resolution of its images, its low specificity (54% for women less than 50 years) and its operator dependent interpretation seriously limit the use of this modality alone. MRI is a non-invasive technique with a relatively high sensitivity (86% for women below 50 years), but its limitations are the high cost and the waiting time for medical examination, which dedicate it as a monitoring technique in high-risk patients. It is therefore necessary to examine new noninvasive and cost effective methods. In this context, dynamic elastography is a promising approach. It is an emerging quantitative medical imaging technique inspired from palpation and based on the determination of elastic properties (stiffness) of tissues. This thesis aims the development of a novel dynamic ultrasound elastography method for early detection of breast lesions. One of the main problems of dynamic elastography techniques using remote palpation (acoustic radiation force) is the strong attenuation of shear waves. After few wavelengths of propagation, displacement amplitudes considerably decrease and their tracking becomes difficult even impossible. This problem greatly affects biological tissue characterization. Moreover, these techniques give only the information about elasticity while recent studies show that some benign lesions have the same elasticity as malignant lesions which affect the specificity of these techniques and motivate investigation of other physical parameters (e.g. viscosity). The first objective of this thesis is to optimize the acoustic radiation force using frequency adaptation to enhance the amplitude of displacements. An analytical model has been developed to predict the optimal frequency for the generation of the radiation force. Once validated on phantoms (in vitro), this model was used for the prediction of the optimal frequencies for the generation of the radiation force in tissue mimicking phantoms and ex vivo human breast cancer samples obtained after total mastectomy. Gains in magnitude were between 20% to158% for in vitro measurements on agar-gelatin phantoms, and 170% to 336% for ex vivo measurements on a human breast sample, depending on focus depths and attenuations of tested samples. The signal-to-noise ratio was also improved by more than four folds with adapted sequences. We conclude that frequency adaptation is a complementary technique that is efficient for the optimization of displacement amplitudes. This technique can be used safely to optimize the deposited local acoustic energy, without increasing the risk of damaging tissues and transducer elements. In the second part of this thesis, a prototype of an ultrasound probe for the generation of a specific type of adaptive shear waves called ''adaptive torsional shear waves'' has been developed. The goal was to use the optimized radiation force (developed in the first part) to generate adaptive torsional shear wave, and prove their utility in improving the amplitude of displacement. During their inward propagation, the amplitude of displacement generated by torsional shear waves was enhanced and the signal to noise ratio improved due to the constructive interferences. Torsional shear waves can also resonate heterogeneities which further enhance the displacement contrast between suspicious masses and its surrounding medium. Finally, in the context of assessment of mechanical proprieties of tissue, the last step of this thesis is to develop an inverse problem based on the propagation of adaptive torsional shear waves to estimate the viscoelastic parameters. A finite element method (FEM) model was developed to solve the inverse wave propagation problem and obtain viscoelastic properties of interrogated media. The inverse problem was formulated and solved in the frequency domain and its robustness was evaluated. The proposed model was validated in vitro with two independent rheology methods on several homogeneous and heterogeneous breast tissue mimicking phantoms over a broad range of frequencies (up to 400Hz). The obtained results were in good agreement with reference rheology methods with discrepancies between 8% and 38% for shear modulus and from 9% to 67% for loss modulus. The robustness study showed that the proposed inverse problem solution yielded a good estimation of the storage (19%) and loss moduli (32%) even with very noisy signals.
94

Deep water Gulf of Mexico pore pressure estimation utilizing P-SV waves from multicomponent seismic in Atlantis Field

Kao, Jeffrey Chung-chen 08 September 2010 (has links)
Overpressure, or abnormally low effective pressures, is hazardous in drilling operations and construction of sea-bottom facilities in deepwater environments. Estimation of the locations of overpressure can improve safety in these operations and significantly reduce overall project costs. Propagation velocities of both seismic P and S wave are sensitive to bulk elastic parameters and density of the sediments, which can be related to porosity, pore fluid content, lithology, and effective pressures. Overpressured areas can be analyzed using 4C seismic reflection data, which includes P-P and P-SV reflections. In this thesis, the effects on compressional (P) and shear (S) wave velocities are investigated to estimate the magnitude and location of excess pore pressure utilizing Eaton’s approach for pressure prediction (Eaton, 1969). Eaton’s (1969) method relates changes in pore pressure to changes in seismic P-wave velocity. The underlying assumption of this method utilizes the ratio of observed P-wave velocity obtained from areas of both normal and abnormal pressure. This velocity ratio evaluated through an empirically determined exponent is then related to the ratio of effective stress under normal and abnormal pressure conditions. Effective stress in a normal pressured condition is greater than the effective stress value in abnormally overpressured conditions. Due to an increased sensitivity of variations in effective pressure to seismic interval velocity, Ebrom et al. (2003) employ a modified Eaton equation to incorporate the S-wave velocity in pore pressure prediction. The data preparation and subsequent observations of seismic P and S wave velocity estimates in this thesis represent a preliminary analysis for pore pressure prediction. Six 2D receiver gathers in the regional dip direction are extracted from six individual ocean-bottom 4C seismic recording nodes for P-P and P-SV velocity analysis. The receiver gathers employed have minimal pre-processing procedures applied. The main processing steps applied were: water bottom mute, 2D rotation of horizontal components to SV and SH orientation, deconvolution, and frequency filtering. Most the processing was performed in Matlab with a volume of scripts designed by research scientists from the University of Texas, Bureau of Economic Geology. In this thesis, fluid pressure prediction is estimated utilizing several 4C multicomponent ocean-bottom nodes in the Atlantis Field in deepwater Gulf of Mexico. Velocity analysis is performed through a ray tracing approach utilizing P-P and P-SV registration. A modified Eaton’s Algorithm is then used for pore pressure prediction using both P and S wave velocity values. I was able to successfully observe both compressional and shear wave velocities to sediment depths of approximately 800 m below the seafloor. Using Hamilton (1972, 1976) and Eberhart-Phillips et al. (1989) regressions as background depth dependent velocity values and well-log derived background effective pressure values from deepwater Gulf of Mexico, I am able to solve for predicted effective pressure for the study area. The results show that the Atlantis subsurface study area experiences a degree of overpressure. / text
95

Extrusion processing of chocolate crumb paste

Walker, Alasdair Michael January 2012 (has links)
This project considers the co-rotating twin screw extrusion of a confectionery paste comprising powdered proteins, sugars, water and fats. As is the case with many food industry products, this process has been developed experimentally with little quantitative understanding of how variations in processing conditions influence the formation of the extrudate. A variety of techniques have therefore been developed to characterise and quantify the dispersive mixing, distributive mixing and rheological flow properties of this complex, multiphase, viscoelastic, unstable material. These techniques have then been utilised in a pilot plant extruder study of the mechanics of mixing and paste formation during extrusion, considering the influence of both processing conditions and screw profile. The internal evolution of paste microstructure has been successfully tracked along the length of screw profile using dead-stop extractions of the screws. A rigorous off-line assessment of shear yield strength behaviour using cone penetrometry has shown the use of conventional off-line rheometers to be unviable due to rapid post extrusion hardening. This highlighted the need for an in-line rheological measurement technique for continuous extrusion analysis where the extruded material is severely time dependent and not extractable. In pursuit of this, a novel arrangement of bender elements is proposed and trialled, to rapidly characterise material parameters of viscoelastic pastes. A second technique looking to extend the application of shear wave interface reflection to multiphase pastes is also trialled. A novel analysis of thermogravimetric data (TGA) has generated a viable index of distributive mixing, suitable for use on complex multi-component materials where thermal decomposition temperatures of the components are not well defined. Quantitative image analysis of pastes using scanning electron microscopy (SEM), optical microscopy protein staining and a novel application of multiphoton microscopy (MPM) have been used to visualise paste microstructure and quantify dispersive mixing. From the pilot plant extruder study, the application of these techniques was successful in mapping the evolution of paste mixing and the resulting microstructure, as well as identifying key differences between pastes mixed by twin screw extrusion and batch mixing.
96

Elastographie pour le suivi des thérapies par ultrasons focalisés et nouveau concept de cavité à retournement temporel pour l'histotripsie

Arnal, Bastien 17 January 2013 (has links) (PDF)
L'émission d'ultrasons focalisés à forte puissance peut être utilisée pour réaliser l'ablation non-invasive de zones pathogènes, de type cancéreuses par exemple. On distingue deux régimes d'ablations : ablation thermique appelée HIFU (" High Intensity Focused Ultrasound ") et ablation mécanique appelée histotripsie utilisant des ondes de chocs focalisées. Au cours de ma thèse, nous avons développé des méthodes de suivi ultrasonore en temps réel à partir d'une technique d'élastographie quantitative (Supersonic Shear wave Imaging). Nous montrerons que des mesures précises des changements d'élasticité au cours des traitements fournissent un suivi et un guidage avec une robustesse aux mouvements du patient. En effet, l'élastographie nous a permis d'une part de cartographier la température et d'autre part de suivre la formation de lésion en temps réel qu'elle soit de type thermique (HIFU) ou mécanique (histotripsie). Nous aborderons aussi une technique d'inversion totale du front d'onde appliquée à SSI qui améliore la sensibilité à la perte d'information due au bruit et à l'hypoéchogénicité existante dans certaines lésions. Enfin, nous présenterons un nouveau concept de cavité à retournement temporel " réglable " pour l'émission d'impulsions de très fortes pressions à partir d'un nombre limité de transducteurs. Notre prototype a permis de générer des ondes de chocs focalisées au sein d'une étendue considérable et de multiplier par 17 la pression d'une sonde d'imagerie conventionnelle. Ainsi, à partir d'électroniques basse-puissance à faible coût, ce dispositif thérapeutique pourrait avoir de nombreuses applications thérapeutiques limitées actuellement par des contraintes géométriques.
97

Apport de l’élastographie par imagerie des ondes de cisaillement pour l’évaluation de la photo-polymerisation du collagène cornéen / Contribution of shear wave imaging elastography for corneal collagen photo-polymerization assessment

Touboul, David 26 May 2014 (has links)
Le cross-linking du collagène cornéen (CXL) est une cornéoplastie mini-invasive reposant surun concept biomécanique difficile à objectiver physiquement et dont les preuves del’efficacité thérapeutique sont d’interprétation complexe. Les principes, les nuances et lesrésultats du CXL sont colligés dans cette thèse afin de valider l’intérêt du modèleexpérimental choisi pour tester la pertinence de notre travail de recherche sur l’élastographiecornéenne par ondes de cisaillement.Notre cheminement expérimental a abouti au choix du modèle de CXL trans-épithélial (TCXL)assisté par iontophorèse (I-CXL), réalisé in vivo, sur oeil de lapin. Les mesuresélastographiques obtenues après euthanasie ont ainsi pu démontrer une modificationsignificative du profil d’élasticité de la cornée après CXL, testé successivement de manièredynamique et statique.Nos résultats confirment donc l’efficacité biomécanique instantanée du I-CXL et donnent uneidée plus précise de la valeur de la photo-polymérisation du tissu cornéen isolée desphénomènes liés à la cicatrisation. Les enjeux technologiques de l’élastographe cornéen paranalyse des ondes de cisaillement ont pu être définis afin de développer une stratégie de miseen oeuvre d’un système pertinent pour la pratique clinique. / Corneal collagen cross-linking (CXL) is a kind of minimaly invasive corneoplasty mainlybased on a biomechanical concept, which is very difficult to measure physically, and whichthe therapeutic efficacy understanding is complex.Principles, different protocols and resultsare summarized in this thesis in order to illustrate the usefulness of the experimental modelchosen in our experimentations about elastographic corneal shear wave imaging.The pathway of our experimental work have led to the choice of trans-epithelial CXL (TCXL)assisted by iontophoresis (I-CXL), performed in vivo, on rabbits eyes. Elastographicmeasurements we obtained after animals euthanasia have shown a significant change of thecorneal elasticity profile after CXL, successively tested in a dynamic and in a static fashion.Our results do confirm the biomechanical efficacy of the I-CXL procedure and give a moreprecise idea of the sole photo-polymerization effect by avoiding any confounding healingconcern. Technological issues for corneal elastography with shear wave imaging have beenraised in this thesis to develop a realistic strategy for the launch of a clinically useful device.
98

Amélioration des techniques d’ablation pour le traitement des arythmies cardiaques : nouvelles modalités diagnostiques et thérapeutiques par ultrasons / Diagnostic and therapeutic ultrasound techniques to improve ablation of cardiac arrhythmias

Bessière, Francis 06 November 2019 (has links)
A la croisée des chemins entre médecine et physique des ultrasons, ce travail de thèse s’est intéressé à l’apport de solutions diagnostiques et de thérapeutiques novatrices dans le domaine de l’électrophysiologie cardiaque. Un système capable de délivrer des ultrasons focalisés dans le cœur par voie transoesophagienne sous guidage par ultrasons a été développé et testé in vivo chez 6 porcs. Les tirs HIFU ont été délivrés sur les oreillettes et les ventricules. Lors de l'autopsie, une analyse visuelle a démontré la présence de lésions thermiques dans les zones ciblées chez 3 animaux. Ces lésions ont été confirmées par analyse histologique (taille moyenne: 5,5 mm2 x 11 mm2). Aucune lésion thermique œsophagienne n'a été observée. Un animal a présenté une bradycardie due à un bloc auriculo-ventriculaire, ce qui a permis de confirmer une réelle interaction entre les tirs HIFU et le tissu nodal cardiaque. Nous avons cependant observé un manque de précision, principalement lié aux mouvements cardiaques ainsi qu’aux structures anatomiques situées entre les zones ciblées et le transducteur de thérapie. Ces difficultés ont été principalement reliées à l’anatomie du modèle porcin, loin de celle de l’être humain. La recherche d'un meilleur modèle a conduit à des tests d'imagerie concluants sur des babouins.Des expériences supplémentaires ont été conduites afin d'améliorer la cartographie des arythmies ventriculaires et le suivi de la formation de lésions pendant l'ablation.Des expériences ont été menées sur les ventricules gauches de quatre coeurs de porcs en mode travaillant. Le protocole visait à démontrer que différents modèles d'activation mécanique pouvaient être observés, que le ventricule soit en rythme sinusal, stimulé depuis l'épicarde ou l'endocarde. Des acquisitions d’imagerie de déformation électromécanique (EWI) ont été enregistrées sur les faces antérieures, latérales et postérieures du ventricule gauche. Les boucles ont été ensuite analysées à l’aveugle par deux lecteurs indépendants.Les interprétations des séquences EWI étaient correctes dans 89% des cas. Le taux de concordance globale entre les deux lecteurs était de 83%. Dans un ventricule stimulé, l'origine du front d'onde était focale et provenait de l'endocarde ou de l'épicarde stimulé. En rythme sinusal, le front d'onde était activé depuis tout l'endocarde, en direction de l'épicarde, à une vitesse de 1,7 ± 0,28 m.s-1. Les vitesses du front d'onde ont été mesurées respectivement lorsque l'endocarde ou l'épicarde étaient stimulés à une vitesse de 1,1 ± 0,35 m.s -1 et 1,3 ± 0,34 m.s-1 (p = NS). Nous avons aussi démontré sur des échantillons ex-vivo que l'imagerie trans oesophagienne par analyse des ondes de cisaillement (élastographie) pouvait cartographier l'étendue des lésions HIFU. Des tirs HIFU ont été réalisés à l'aide de la sonde trans oesophagienne sur des échantillons de blancs de poulet (n = 3), puis sur un modèle porcin ex vivo d'oreillette (gauche, n = 2) et de ventricule gauche (n = 1). L’élastographie a fourni des cartes de rigidité des tissus avant et après l'ablation. Les zones des lésions ont été obtenues par analyse et quantification des changements de couleur des tissus puis ont été comparées aux images par élastographie. Dans le blanc de poulet, la rigidité est passée en moyenne de 4.8±1.1 kPa à 20.5±10.0 kPa (ratio 5.0±3.2). Dans le ventricule gauche, la rigidité est passée en moyenne de 21.2±3.3kPa à 73.8±13.9kPa (ratio 3.7±1.2). Dans l’oreillette gauche, la rigidité est passée en moyenne de 12.2±4.3 kPa à 30.3±10.3 (ratio 3.2±2.0). En histologie, la taille des lésions variait de 0.1 à 1.5 cm2 dans la zone du plan d'imagerie. Les caractéristiques morphométriques étaient similaires entre histologie et élastographie / At the crossroads of medicine and physics, this work aimed to provide innovative diagnostic and therapeutic tools based on ultrasound, in the field of cardiac electrophysiology. A system capable of delivering HIFU into the heart by a transesophageal route using ultrasound (US) imaging guidance was developed and tested in vivo in six male pigs. HIFU exposures were performed on atria and ventricles. At the time of autopsy, visual inspection identified thermal lesions in the targeted areas in three of the animals. These lesions were confirmed by histologic analysis (mean size: 5.5 mm2 x 11mm2). No esophageal thermal injury was observed. One animal presented with bradycardia due to an atrio-ventricular block, which provides real-time confirmation of an interaction between HIFU and the electrical circuits of the heart. There was still a lack of accuracy, mainly related to cardiac motion, and to anatomical structures in between the targets and the transducer. It was mainly related to the in vivo model and its anatomy, far from the human’s. The search for a better model led to conclusive imaging tests on baboons. Additional experiments were conduced in order to improve the mapping of ventricular arrhythmias and the monitoring of lesion formation during ablation. First, experiments were conducted on left ventricles of four isolated working mode swine hearts. The protocol aimed at demonstrating that different patterns of mechanical activation could be observed whether the ventricle was in sinus rhythm, paced from the epicardium, or from the endocardium. Electromechanical wave imaging (EWI) acquisitions were recorded on the anterior, lateral, and posterior segments of the left ventricle. Loop records were blindly assigned to two readers. EWI sequences interpretations were correct in 89% of cases. The overall agreement rate between the two readers was 83%. When in a paced ventricle, the origin of the wave front was focal and originating from the endocardium or the epicardium. In sinus rhythm, wave front was global and activated within the entire endocardium towards the epicardium at a speed of 1.7±0.28 m.s-1. Wave front speeds were respectively measured when the endocardium or the epicardium were paced at a speed of 1.1 ± 0.35 m.s-1 vs 1.3±0.34 m.s-1 (p=NS). Lastly, we investigated the feasibility of a dual therapy and imaging approach with the same transoesophageal device. We demonstrated on ex-vivo samples that transoesophageal shear wave imaging (SWE) can map the extent of the HIFU lesions. HIFU ablation was performed with the transoesophageal probe on ex-vivo chicken breast samples (n=3), then atrium (left, n=2) and ventricle (left n=1, right n=1) of swine heart tissues. SWE provided stiffness maps of the tissues before and after ablation. Areas of the lesions were obtained by tissue color change with gross pathology and compared to SWE. Shear modulus of the ablated zones increased from 4.8±1.1 kPa to 20.5+/-10.0 kPa (ratio 5.0±3.2) in the chicken breast, from 12.2±4.3 kPa to 30.3±10.3 (ratio 3.2±2.0) in the atria and from 21.2±3.3kPa to 73.8±13.9kPa (ratio 3.7±1.2) in the ventricles. On gross pathology, the size of the lesions ranged from 0.1 to 1.5cm2 in the imaging plane area and morphometric characteristics were fitting with elasticity-estimated depths and widths of the lesions
99

Messung der Lebersteifigkeit mittels der 2D-Scherwellen-Elastographie mit dem Sonographiegerät LOGIQ E9 (Firma GE Healthcare) bei gesunden Probanden, Leber-gesunden Patienten sowie Patienten mit Leberzirrhose zur Generierung von Normwerten / Measurement of liver stiffness using 2D shear wave elastography with the sonography device LOGIQ E9 (GE Healthcare) in healthy subjects, liver-healthy patients and patients with cirrhosis to generate normal values

Hofer, Johannes Albertus 16 June 2020 (has links)
No description available.
100

Correlación entre el número de golpes N60 del Ensayo de Penetración Estándar y la Velocidad de ondas de corte (Vs) para los suelos arenosos del distrito de Juliaca – Puno / Correlation between the number of blows N60 of the Standard Penetration Test and the velocity of shear waves (Vs) for the sandy soils of the Juliaca district - Puno

Alata Rodriguez, Jair Angelo, Zevillanos Ninancuro, Wilfredo 08 April 2021 (has links)
La aplicación del ensayo de penetración estándar (SPT) conlleva a un nivel de detalle alto, así mismo es costosa, requiere de mano de obra calificada para su ejecución y es demorada; su utilización es recomendada en suelos arenosos, restrictiva en suelos finos y plásticos y no recomendada en los demás tipos de suelos. Mientras que en el Análisis multicanal de ondas superficiales (MASW) su ejecución no se restringe, permite abarcar grandes áreas en tiempos cortos, no obstante, es un método indirecto, razón por la cual su aplicación debe ser verificada mediante perforaciones, obtención de muestras, y altos criterios de análisis. En los últimos años la implementación y mejoramiento de las técnicas de prospección de suelos ha permitido investigar la relación de dichos ensayos con diferentes parámetros del suelo. En la presente se desarrolló una correlación empírica entre los ensayos geotécnicos SPT mediante el número de golpes de resistencia a la penetración (N60) con el valor de las velocidades de ondas de corte (Vs) de los ensayos geofísicos MASW, se realizaron en 30 puntos del distrito de Juliaca para los suelos arenosos. Se contó con un filtro final de 110 pares ordenados de datos (Vs; N60); mediante el análisis de regresión potencial por el método de mínimos cuadrados donde se obtuvo la ecuación: Vs = 81.079*N600.2646; y un coeficiente de determinación R2:0.76. Esta ecuación fue puesta en análisis comparativo con las ecuaciones de las correlaciones de la literatura, en el cual se encontró una tendencia acorde a las mismas, lo que permitirá utilizarla con suelos afines a la región. / The application of the standard penetration test (SPT) entails a high level of detail, it is also expensive, requires qualified labor for its execution and is time-consuming; Its use is recommended in sandy soils, restrictive in fine and plastic soils and not recommended in other types of soils. While in the multichannel analysis of surface waves (MASW) its execution is not restricted, it allows covering large areas in short times, however, it is an indirect method, which is why its application must be verified by drilling, obtaining samples, and high analytical criteria. In recent years, the implementation and improvement of soil prospecting techniques has made it possible to carry out studies of the relationship of said tests with different soil parameters. In the present, an empirical correlation was developed between the SPT geotechnical tests by means of the number of penetration resistance blows (N60) with the value of the shear wave velocities (Vs) of the MASW geophysical tests, these tests were carried out in 30 points in the city of Juliaca for sandy soils. There was a final filter of 110 ordered pairs of data (Vs; N60); Through the analysis of potential regression by the method of least squares, the equation was obtained: Vs = 81.079*N600.2646; of the determination coefficient R2:0.76, it was determined that the correlation is acceptable. This equation was put into analysis and comparison with the equations of the correlations of the literature, in which it was found in a trend according to them. / Tesis

Page generated in 0.0373 seconds