• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 23
  • 22
  • 7
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 118
  • 59
  • 57
  • 56
  • 24
  • 19
  • 18
  • 18
  • 17
  • 16
  • 15
  • 14
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Frequency steerable acoustic transducers

Senesi, Matteo 22 June 2012 (has links)
Structural health monitoring (SHM) is an active research area devoted to the assessment of the structural integrity of critical components of aerospace, civil and mechanical systems. Guided wave methods have been proposed for SHM of plate-like structures using permanently attached piezoelectric transducers, which generate and sense waves to evaluate the presence of damage. Effective interrogation of structural health is often facilitated by sensors and actuators with the ability to perform directional scanning. In this research, the novel class of Frequency Steerable Acoustic Transducers (FSATs) is proposed for directional generation/sensing of guided waves. The FSATs are characterized by a spatial arrangement of the piezoelectric material which leads to frequency-dependent directionality. The resulting FSATs can be employed both for directional sensing and generation of guided waves, without relying on phasing and control of a large number of channels. Because there is no need for individual control of transducer elements, hardware and power requirements are drastically reduced so that cost and hardware limitations of traditional phased arrays can be partially overcome. The FSATs can be also good candidates for remote sensing and actuation applications, due to their hardware simplicity and robustness. Validation of the proposed concepts first employs numerical methods. Next, the prototyping of the FSATs allows an experimental investigation confirming the analytical and numerical predictions. Imaging algorithm based on frequency warping is also proposed to enhance results representation.
42

Multi-Component Structural Health Assessment Using Guided Acoustic Waves

Amjad, Umar January 2014 (has links)
In this dissertation different structural materials (aluminum and steel) with different geometrical shapes (plates, pipes and bars) are studied for damage detection with guided waves. Specific guided wave modes (also known as Lamb wave modes for plate type structures) are generated in a laminated aluminum plate for damage detection and quantification using a broad band piezoelectric transducer structured with a rigid electrode. Appropriate excitation frequencies and modes for inspection are selected from theoretical and experimental dispersion curves. Sensitivity of anti-symmetric and symmetric modes for delamination detection and quantification is investigated. Longitudinal guided waves are excited and recorded after transmission through reinforcing steel bars for monitoring its corrosion level. Instead of investigating the amplitude of the transmitted guided waves, or in other words, monitoring its attenuation, the differential time-of-flight (TOF) is recorded. A reliable guided wave mode is identified for the detection and quantification of corrosion in reinforcing steel bars. Hole type damage, and bonding/de-bonding or lamination/delamination in pipes are studied with Noncontact Electro-Magnetic Acoustic Transducers and PZT transducers. An adaptive method using phase of the recorded signals for detection and quantification of damages in pipes is established using multiple feature extraction techniques (Time-Frequency representations) and differential time-of-flight cross-correlation technique.
43

Localização de danos em estruturas isotrópicas com a utilização de aprendizado de máquina /

Oliveira, Daniela Cabral de January 2017 (has links)
Orientador: Vicente Lopes Júnior / Resumo: Este trabalho introduz uma nova metodologia de Monitoramento da Integridade de Estruturas (SHM, do inglês Structural Health Monitoring) utilizando algoritmos de aprendizado de máquina não-supervisionado para localização e detecção de dano. A abordagem foi testada em material isotrópico (placa de alumínio). Os dados experimentais foram cedidos por Rosa (2016). O banco de dados disponibilizado é abrangente e inclui medidas em diversas situações. Os transdutores piezelétricos foram colados na placa de alumínio com dimensões de 500 x 500 x 2mm, que atuam como sensores e atuadores ao mesmo tempo. Para manipulação dos dados foram analisados os sinais definindo o primeiro pacote do sinal (first packet), considerando apenas o intervalo de tempo igual ao tempo da força de excitação. Neste caso, na há interferência dos sinais refletidos nas bordas da estrutura. Os sinais são obtidos na situação sem dano (baseline) e, posteriormente nas diversas situações de dano. Como método de avaliação do quanto o dano interfere em cada caminho, foram implementadas as seguintes métricas: pico máximo, valor médio quadrático (RMSD), correlação entre os sinais, normas H2 e H∞ entre os sinais baseline e sinais com dano. Logo após o cálculo das métricas para as diversas situações de dano, foi implementado o algoritmo de aprendizado de máquina não-supervisionado K-Means no matlab e também testado no toolbox Weka. No algoritmo K-Means há a necessidade da pré-determinação do número de clusters e isto pode di... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
44

Desenvolvimento de um modelo eletromecânico para diafragmas piezelétricos utilizados em sistemas de monitoramento de integridade estrutural / Development of an electromechanical model for piezoelectric diaphragms used in structural health monitoring systems

Freitas, Everaldo Silva de 23 July 2018 (has links)
Submitted by EVERALDO SILVA DE FREITAS null (everaldo.freitas@gmail.com) on 2018-09-12T02:59:57Z No. of bitstreams: 1 Tese_Doutorado_Everaldo_Freitas_FINAL_2018_ok.pdf: 1723520 bytes, checksum: dbd1b513bc9fa19ca8ac81016da5d0a9 (MD5) / Approved for entry into archive by Lucilene Cordeiro da Silva Messias null (lubiblio@bauru.unesp.br) on 2018-09-12T12:56:03Z (GMT) No. of bitstreams: 1 freitas_es_dr_bauru.pdf: 1679310 bytes, checksum: e2ca0b29e71f13ee7094695c96036f7a (MD5) / Made available in DSpace on 2018-09-12T12:56:03Z (GMT). No. of bitstreams: 1 freitas_es_dr_bauru.pdf: 1679310 bytes, checksum: e2ca0b29e71f13ee7094695c96036f7a (MD5) Previous issue date: 2018-07-23 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Os diafragmas piezelétricos são componentes eletrônicos de baixo custo utilizados em diversas aplicações. Seu uso mais comum é como transdutor de áudio e, nesse tipo de aplicação, é mais comumente conhecido como buzzer. Nos últimos anos, a utilização desses componentes em estudos científicos avançados tem aumentado bastante, e uma das áreas que tem merecido destaque é a dos sistemas de Monitoramento de Integridade Estrutural – Structural Health Monitoring (SHM) – baseados na técnica da impedância eletromecânica (E/M). Esse tipo de aplicação tem recebido uma atenção especial por se basear no uso de transdutores piezelétricos pequenos e leves minimamente invasivos à estrutura monitorada. Portanto, tomando como base o crescente interesse por esses componentes, é proposto neste estudo um circuito eletromecânico equivalente básico que relacione as propriedades elétricas dos diafragmas piezelétricos com as propriedades mecânicas da estrutura monitorada por meio da impedância elétrica. Essa relação é baseada no efeito piezelétrico, que proporciona um acoplamento eletromecânico com a estrutura monitorada e, portanto, permite avaliar as condições mecânicas da estrutura a partir das propriedades elétricas do transdutor. A estrutura utilizada no estudo foi uma barra de alumínio com dimensões de 500 mm x 38,10 mm x 3,18 mm, tipicamente utilizada em laboratórios, e diafragmas com espessuras da ordem de uma fração de milímetro. Nessas condições, o modo de vibração principal pode ser considerado na direção longitudinal da estrutura para uma suposição unidimensional, de forma que o diafragma piezelétrico pode ser representado como um hexapolo com três portas, sendo uma porta elétrica e duas portas acústicas, solução esta comumente usada na literatura. As sensibilidades aos danos estruturais foram teoricamente analisadas em três diafragmas de diferentes tamanhos utilizando o circuito equivalente proposto. Essas sensibilidades foram comparadas com a de uma cerâmica piezelétrica convencional, que é o transdutor comumente utilizado no método da impedância E/M. Além disso, testes experimentais foram realizados em barras de alumínio para validação do circuito equivalente. Pode-se concluir que há correspondência entre os resultados teóricos e experimentais, pois as sensibilidades dos transdutores em ambas as análises foram próximas com poucas variações. / Piezoelectric diaphragms are inexpensive electronic components used in a variety of applications. Its most common use is as an audio transducer and, in this type of application, it is commonly known as "buzzer". In recent years, the use of these components in advanced scientific studies has increased significantly, and one of the areas that has received special mention is the Structural Health Monitoring (SHM) systems based on electromechanical impedance (EMI). This type of application has received special attention because it is based on the use of small and lightweight piezoelectric transducers minimally invasive to the monitored structure. Therefore, based on the growing interest in these components, a basic equivalent electromechanical circuit is proposed in this study that relates the electrical properties of the piezoelectric diaphragms to the mechanical properties of the monitored structure through the electrical impedance. This relationship is based on the piezoelectric effect, which provides an electromechanical coupling with the monitored structure and, therefore, allows to evaluate the mechanical conditions of the structure from the electrical properties of the transducer. The structure used in the study was an aluminum bar with dimensions of 500 mm x 38.10 mm x 3.18 mm, typically used in laboratories, and diaphragms with thicknesses of the order of a fraction of millimeter. Under these conditions, the main vibration mode can be considered in the longitudinal direction of the structure for a one-dimensional assumption, so that the piezoelectric diaphragm can be represented as a three-port hexapolo, one electric port and two acoustic ports, which is a solution commonly used in the literature. Sensitivities to structural damage were theoretically analyzed in three diaphragms of different sizes using the proposed equivalent circuit. These sensitivities were compared with that of a conventional piezoelectric ceramic, which is the transducer commonly used in the EMI method. In addition, experimental tests were performed on aluminum bars for equivalent circuit validation. It can be concluded that there is a correspondence between the theoretical and experimental results, because the sensitivities of the transducers in both analyzes were close with few variations. / FAPESP: 2015/02500-6
45

Seleção da faixa de frequência usando wavelets para detecção de danos em sistemas SHM baseados no princípio da EMI /

Vieira, Patrícia Gabriel January 2016 (has links)
Orientador: Jozue Vieira Filho / Resumo: Neste trabalho aplica-se a Transformada Wavelet Packet para a identificação de faixas de frequência para detecção de danos em sistemas de monitoramento de integridade estrutural baseados no princípio da impedância eletromecânica no domínio do tempo. Assim, foram verificadas e determinadas as faixas de frequências que melhor representam as variações no conjunto PZT/estrutura por meio de informações obtidas da Transformada Wavelet Packet aplicada no sinal de resposta do conjunto PZT/estrutura, obtendo uma metodologia viável, fácil e simples para escolher a faixa mais sensível para a detecção de danos. Os resultados indicam que a entropia dos coeficientes wavelet é uma importante referência na seleção da banda mais apropriada para a detecção de danos. / Abstract: This work applies the Wavelet Packet Transform in the identification of frequency bands for damage detection in structural health monitoring systems based on the principle of electromechanical impedance in the time domain. Thus, the frequency bands that best represent the variations in the set PZT/structure were obtained and determined by means of the information obtained from the Wavelet Packet Transform applied to response signal obtained from PZT/structure, which is an easy, simple and viable methodology for choosing the more sensitive frequency bands for damage detection. Results indicate that the entropy of wavelet coefficients is an important reference in selecting the most appropriate band for damage detection. / Mestre
46

Análise experimental de diafragmas piezelétricos comerciais para detecção de dano estrutural baseada na impedância eletromecânica / Experimental analysis of commercial piezoelectric diaphragms for structural damage detection based on the electromechanical impedance

Freitas, Everaldo Silva de [UNESP] 30 May 2016 (has links)
Submitted by EVERALDO SILVA DE FREITAS null (everaldo.freitas@gmail.com) on 2016-07-03T18:42:32Z No. of bitstreams: 1 Dissertação_Mestrado_Everaldo_Freitas_2016_final.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-07-07T16:33:04Z (GMT) No. of bitstreams: 1 freitas_es_me_bauru.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) / Made available in DSpace on 2016-07-07T16:33:04Z (GMT). No. of bitstreams: 1 freitas_es_me_bauru.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) Previous issue date: 2016-05-30 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta dissertação de mestrado apresenta uma análise experimental da viabilidade do uso dos diafragmas piezelétricos comerciais de baixo custo (comumente conhecidos como buzzers) em sistemas de monitoramento de integridade estrutural (SHM – Structural Health Monitoring) baseados na técnica da impedância eletromecânica (E/M). Esse tipo de aplicação tem recebido uma atenção especial nas últimas décadas por se basear no uso de transdutores piezelétricos pequenos e leves que operam simultaneamente como sensores e atuadores. Foram realizados vários testes em barras de alumínio utilizando diafragmas de diversos tamanhos; as assinaturas de impedância elétrica e os índices de dano foram comparados com os obtidos usando uma cerâmica convencional de PZT (Pb-lead Zirconate Titanate – titanato zirconato de chumbo), que é o transdutor mais comumente utilizado nessa aplicação. Os danos estruturais foram simulados utilizando-se massas metálicas (porcas de parafuso), as quais foram fixadas nas barras com cola a base de cianoacrilato. Quatro tipos de experimentos foram realizados para fins de comparação: estimação da sensibilidade dos transdutores utilizando método da quebra do grafite (PLB – Pencil Lead Break – quebra do grafite); comparação dos índices de dano RMSD (root mean square deviation – desvio da raiz média quadrática) e CCDM (correlation coefficient deviation metric – métrica do desvio do coeficiente de correlação), calculados a partir das assinaturas de impedância; avaliação dos efeitos da temperatura; e a avaliação da reprodutibilidade dos resultados a longo prazo. Os resultados indicaram que a cerâmica convencional de PZT e um diafragma de tamanho semelhante apresentam características bem próximas em relação à reprodutibilidade dos resultados, sensibilidade ao dano e aos efeitos de temperatura, o que leva a conclusão de que os diafragmas são viáveis para sistemas de SHM baseados na impedância E/M. / This dissertation presents an experimental analysis of the viability of low-cost commercial piezoelectric diaphragms (commonly known as buzzers) in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique. This application has received special attention in recent decades because it is based on the use of small, lightweight piezoelectric transducers operating as both sensors and actuators. Several tests were carried out on aluminum bars using diaphragms of different sizes; the electrical impedance signatures and damage indices were compared with those obtained using a conventional PZT (Pb-Lead Zirconate Titanate) ceramic, which is the most commonly employed transducer in this application. Structural damage was simulated using metallic bolts (steel nut), which were fixed in the bars using cyanoacrylate glue. Four types of experiments were carried out for comparison between the two transducers: sensitivity estimation using the pencil lead break (PLB) method, analysis of the feasibility to detect structural damage using conventional impedance signatures and damage indices, analysis of temperature effects, and determination of the long-term reproducibility of the results. The results indicated that conventional PZT ceramics and diaphragms with similar size exhibit very close characteristics in relation to reproducibility, sensitivity to damage and temperature effects, which leads to the conclusion that the piezoelectric diaphragms are feasible in SHM systems based on the EMI method. / FAPESP: 2015/02500-6
47

Seleção da faixa de frequência usando wavelets para detecção de danos em sistemas SHM baseados no princípio da EMI / Selection of the frequency band using wavelets to detect damage in SHM systems based on the principle of EMI

Vieira, Patrícia Gabriel [UNESP] 19 December 2016 (has links)
Submitted by PATRÍCIA GABRIEL VIEIRA null (vieiragpatricia@gmail.com) on 2017-01-23T20:36:55Z No. of bitstreams: 1 Patricia_G_Vieira_Dissertação_Final_2016.pdf: 1483125 bytes, checksum: 78eb2fa98b77bc55ffb7c6344532d7a9 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-01-26T13:40:48Z (GMT) No. of bitstreams: 1 vieira_pg_me_ilha.pdf: 1483125 bytes, checksum: 78eb2fa98b77bc55ffb7c6344532d7a9 (MD5) / Made available in DSpace on 2017-01-26T13:40:48Z (GMT). No. of bitstreams: 1 vieira_pg_me_ilha.pdf: 1483125 bytes, checksum: 78eb2fa98b77bc55ffb7c6344532d7a9 (MD5) Previous issue date: 2016-12-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho aplica-se a Transformada Wavelet Packet para a identificação de faixas de frequência para detecção de danos em sistemas de monitoramento de integridade estrutural baseados no princípio da impedância eletromecânica no domínio do tempo. Assim, foram verificadas e determinadas as faixas de frequências que melhor representam as variações no conjunto PZT/estrutura por meio de informações obtidas da Transformada Wavelet Packet aplicada no sinal de resposta do conjunto PZT/estrutura, obtendo uma metodologia viável, fácil e simples para escolher a faixa mais sensível para a detecção de danos. Os resultados indicam que a entropia dos coeficientes wavelet é uma importante referência na seleção da banda mais apropriada para a detecção de danos. / This work applies the Wavelet Packet Transform in the identification of frequency bands for damage detection in structural health monitoring systems based on the principle of electromechanical impedance in the time domain. Thus, the frequency bands that best represent the variations in the set PZT/structure were obtained and determined by means of the information obtained from the Wavelet Packet Transform applied to response signal obtained from PZT/structure, which is an easy, simple and viable methodology for choosing the more sensitive frequency bands for damage detection. Results indicate that the entropy of wavelet coefficients is an important reference in selecting the most appropriate band for damage detection.
48

Desempenho dos métodos de instalação de transdutores piezelétricos em sistemas de monitoramento de integridade estrutural baseados na impedância eletromecânica / Performance of installation methods in piezoelectrics transducers in structural integrity monitoring systems based on electromechanical impedance

Silveira, Ricardo Zanni Mendes da [UNESP] 26 May 2017 (has links)
Submitted by RICARDO ZANNI MENDES DA SILVEIRA null (ricazanni@gmail.com) on 2017-06-07T16:11:41Z No. of bitstreams: 1 Dissertação_Mestrado_Eng_Eletrica_Ricardo_Zanni_2017.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-07T16:26:32Z (GMT) No. of bitstreams: 1 silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) / Made available in DSpace on 2017-06-07T16:26:32Z (GMT). No. of bitstreams: 1 silveira_rzm_me_bauru.pdf: 2344048 bytes, checksum: b519ada02ffab82aa4fa7f014877a9a4 (MD5) Previous issue date: 2017-05-26 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Transdutores piezelétricos são amplamente utilizados em muitos métodos não destrutivos para a detecção de danos estruturais em aplicações de monitoramento de integridade estrutural ou SHM (Structural Health Monitoring). Dentre os vários métodos não destrutivos, a técnica da impedância eletromecânica (E/M) é conhecida por utilizar cerâmicas piezelétricas pequenas e finas que desempenham simultaneamente as funções de atuador e sensor. O método convencional de instalação dessas cerâmicas piezelétricas na estrutura é utilizando um adesivo de alta rigidez como cola a base de epóxi ou cianoacrilato. No entanto, alguns estudos propõem métodos alternativos de instalação do transdutor, visando a sua reutilização ou que permitam o monitoramento em condições adversas sob as quais a instalação direta do sensor não seria possível. Assim, esta dissertação de mestrado apresenta uma análise experimental comparativa entre os principais métodos de acoplamento entre o transdutor piezelétrico e a estrutura monitorada em sistemas de SHM baseados na técnica da impedância eletromecânica (E/M). Os acoplamentos dos transdutores piezelétricos foram realizados pelos métodos da instalação direta, também conhecida como instalação convencional, por acoplamento magnético e lâminas de alumínio. O transdutor utilizado para os métodos de acoplamento foi o diafragma piezelétrico, comumente conhecido como buzzer. Testes com os três métodos de instalação foram realizados em estruturas de alumínio e o dano estrutural foi induzido por meio de adição de massa metálica (porca de aço), fixada diretamente na estrutura com cola a base de cianoacrilato. A análise comparativa entre os métodos de instalação foi realizada utilizando índices de danos obtidos das assinaturas de impedância elétrica dos diafragmas piezelétricos, além da função de resposta em frequência (FRF) e da densidade espectral de potência obtida pelo método da quebra do grafite. Os resultados experimentais apontam características importantes para os métodos de instalação, os quais têm influência significativa sobre a resposta em frequência e sensibilidade para a detecção de danos estruturais. / Piezoelectric transducers are widely used in many non-destructive methods for detecting structural damage in Structural Health Monitoring (SHM) applications. Among the various techniques for detecting structural damage, the electromechanical impedance (EMI) technique is known to use fine and small piezoelectric ceramics that simultaneously perform the actuator and sensor functions. The conventional method of installing these piezoelectric ceramics in the structure is by using a high stiffness adhesive such as epoxy or cyanoacrylate based glue. However, some studies propose alternative methods of installing the transducer for reuse or to allow monitoring under adverse conditions under which direct sensor installation would not be possible. Thus, this master's thesis presents a comparative experimental analysis between the main coupling methods between the piezoelectric transducer and the monitored structure in SHM systems based on the electromechanical impedance technique. The piezoelectric transducer couplings were made by direct installation methods, also known as conventional installation, by magnetic coupling and aluminum foils. The transducer used for the coupling methods was the piezoelectric diaphragm, commonly known as buzzer. Tests with these methods were carried out on aluminum structures and the structural damage was induced using metallic masses (steel nuts), fixed directly to the structure with cyanoacrylate-based glue. The comparison of the results analysis between the coupling methods was performed using the indices of damages obtained from electrical impedance signatures of the piezoelectric diaphragm, the frequency response function (FRF) and the power spectral density (PSD) obtained by pencil lead break (PLB) test. The experimental results indicate important characteristics for each installation method and that the mounting method has a significant influence on the frequency response and sensitivity for the detection of structural damage. / FAPESP: 2015/02500-6
49

Detecção de dano estrutural baseada na técnica da impedância eletromecânica em ambientes ruidosos / Detection of structural damage based on the electromechanical impedance technique in noisy environments

Campeiro, Leandro Melo 18 May 2018 (has links)
Submitted by Leandro Melo Campeiro (leandro_campeiro@yahoo.com.br) on 2018-05-24T19:40:02Z No. of bitstreams: 1 Dissertação de Leandro Melo Campeiro.pdf: 3027230 bytes, checksum: 32f869e7ce55b33b1e9c46a166e8cf5f (MD5) / Approved for entry into archive by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br) on 2018-05-25T18:21:44Z (GMT) No. of bitstreams: 1 campeiro_lm_me_bauru.pdf: 3027210 bytes, checksum: 3cff24ecda46e45540b84fc7048c28ff (MD5) / Made available in DSpace on 2018-05-25T18:21:44Z (GMT). No. of bitstreams: 1 campeiro_lm_me_bauru.pdf: 3027210 bytes, checksum: 3cff24ecda46e45540b84fc7048c28ff (MD5) Previous issue date: 2018-05-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A técnica da impedância eletromecânica (E/M) tem sido amplamente estudada nas últimas décadas como um método não destrutivo para detectar danos estruturais em aplicações de monitoramento de integridade estrutural (SHM – structural health monitoring) usando transdutores piezelétricos de baixo custo. Esses transdutores operam simultaneamente como sensor e atuador e são fixados à estrutura monitorada utilizando um adesivo a base de cianoacrilato. Embora muitos estudos tenham relatado a eficácia desse método de detecção, inúmeros problemas práticos têm sido reportados, como os efeitos de ruído e vibração, que precisam ser considerados para permitir o uso eficaz desse método em aplicações reais. Portanto, esta dissertação de mestrado apresenta uma análise experimental dos efeitos do ruído e das vibrações na detecção de danos estruturais em sistemas de SHM baseados na técnica da impedância eletromecânica. Os experimentos foram realizados em uma barra de alumínio usando dois diafragmas piezelétricos, sendo que um deles foi usado para obter as assinaturas de impedância elétrica e o outro foi usado como atuador para introduzir ruído e vibração controlada. Para a simulação de dano foi utilizada uma pequena massa metálica fixada na estrutura com uso de adesivo a base de cianoacrilato. Os efeitos do ruído e da vibração sobre as assinaturas de impedância foram avaliados por meio do cálculo da função de coerência e de índices básicos de dano. Os resultados indicam que a vibração e o ruído afetam significativamente o limiar do menor dano detectável, o qual pode ser compensado pelo aumento do sinal de excitação do transdutor piezelétrico utilizado para a obtenção das assinaturas de impedância elétrica. / The electromechanical impedance (EMI) technique has been extensively studied in recent decades as a non-destructive method for detecting structural damage in structural health monitoring (SHM) applications using low-cost piezoelectric transducers. These transducers operate simultaneously as actuator and sensor and they are fixed to the structure using cyanoacrylate-based glue. Although many studies have reported the effectiveness of this detection method, a lot of practical problems shown up, such as the noise effects and vibration, that need to be addressed to enable this method’s effective use in real applications. Therefore, this master's thesis presents an experimental analysis of noise and vibration effects on the structural damage detection in impedance-based SHM systems. The experiments were performed on an aluminum bar using two piezoelectric diaphragms, where one was used to measure the electrical impedance signatures and the other was used as an actuator to introduce noise and controlled vibration. To simulate damage, a small metal mass was fixed to the structure using cyanoacrylate glue. The effects of noise and vibration on the impedance signatures were evaluated by computing the coherence function and basic damage indices. The results indicate that vibration and noise significantly affect the threshold of the lowest detectable damage, which can be compensated by increasing the excitation signal of the piezoelectric transducer that measure the electrical impedance signature.
50

Inspection of Parts with Complex Geometry and Welds with Structural Health Monitoring Techniques

Korla, Srikanth 15 June 2011 (has links)
Structural Health Monitoring (SHM) systems were developed to evaluate the integrity of a system during operation, and to quickly identify the maintenance problems. They will be used in future aerospace vehicles to improve safety, reduce cost and minimize the maintenance time of a system. Many SHM systems were already developed to evaluate the integrity of plates and used in marine structures. Their implementation in manufacturing processes is still expected. The application of SHM methods for complex geometries and welds are two important challenges in this area of research. This research work started by studying the characteristics of piezoelectric actuators, and a small energy harvester was designed. The output voltages at different frequencies of vibration were acquired to determine the nonlinear characteristics of the piezoelectric stripe actuators. The frequency response was evaluated experimentally. AA battery size energy harvesting devices were developed by using these actuators. When the round and square cross section devices were excited at 50 Hz frequency, they generated 16 V and 25 V respectively. The Surface Response to Excitation (SuRE) and Lamb wave methods were used to estimate the condition of parts with complex geometries. Cutting tools and welded plates were considered. Both approaches used piezoelectric elements that were attached to the surfaces of considered parts. The variation of the magnitude of the frequency response was evaluated when the SuRE method was used. The sum of the square of the differences was calculated. The envelope of the received signal was used for the analysis of wave propagation. Bi-orthogonal wavelet (Binlet) analysis was also used for the evaluation of the data obtained during Lamb wave technique. Both the Lamb wave and SuRE approaches along with the three methods for data analysis worked effectively to detect increasing tool wear. Similarly, they detected defects on the plate, on the weld, and on a separate plate without any sensor as long as it was welded to the test plate.

Page generated in 0.4091 seconds