• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 1
  • Tagged with
  • 341
  • 341
  • 184
  • 139
  • 107
  • 107
  • 68
  • 65
  • 55
  • 52
  • 51
  • 50
  • 41
  • 38
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
171

Interferências da codisposição de resíduos de fossa e tanque séptico em sistemas de lagoas anaeróbias seguidas de facultativas aeradas - Estudo de caso para a ETE- Anápolis / Interference of co-disposing of wastes from cesspool and septic tanks into anaerobic ponds followed by aerated facultative

Oliveira, Getúlio Henrique de 19 July 2013 (has links)
Submitted by Marlene Santos (marlene.bc.ufg@gmail.com) on 2014-10-22T19:58:08Z No. of bitstreams: 2 Dissertação - Getúlio Henrique de Oliveira- 2013.pdf: 2643219 bytes, checksum: 04fc7d8dc87b43e20032d6e2cb521968 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-10-22T20:28:09Z (GMT) No. of bitstreams: 2 Dissertação - Getúlio Henrique de Oliveira- 2013.pdf: 2643219 bytes, checksum: 04fc7d8dc87b43e20032d6e2cb521968 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-10-22T20:28:09Z (GMT). No. of bitstreams: 2 Dissertação - Getúlio Henrique de Oliveira- 2013.pdf: 2643219 bytes, checksum: 04fc7d8dc87b43e20032d6e2cb521968 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-07-19 / The study aimed to assess the impact caused by the waste discharge from cesspools and septic tanks into an anaerobic pond, followed by aerated facultative. Anápolis wastewater treatment plant (WWTP) has two modules of anaerobic ponds followed by aerated facultative, but only one received the waste. By going through a basket retainer of course solids, they were driven directly to the receiver module ponds. The research was divided into three steps: first of all, the system receiving the waste in both modules was evaluated with the rate application volume (RAV) of 0.33%, then, the receiving pond received all of the waste volume disposed in WWTP (RAV = 1.2%), finally the receiving pond was operated with the maximum organic loading and RAV = 0,83%. Samples from different septic tank cleaning trucks were collected and analyzed. Sludge deposited bathymetry was conducted in the anaerobic pond before and after isolation of the modules. The surface scum bulk in the anaerobic pond was removed and quantified. Initially, simple samples were collected from the influent and effluent of anaerobic and facultative aerated ponds weekly, and then, when the receiver module received double flow, samples were collected twice a week. Parameters analyzed were: BOD, COD, Escherichia coli, pH, oil and grease, total phosphorus, amonniacal nitrogen, suspended solids and settleable solids. Data from qualitative characterization of waste cesspools and septic tanks were submitted to descriptive statistics, while referring to the ponds effluents were analyzed by t-test statistical tool. The results indicated the characteristics of the waste are in the range found by other authors, both in national and international literature. A negative impact was evidenced on the receiving anaerobic pond effluent only for the parameters ammonia and settleable solids with the RAV of 1.2%, however, with the rate of 0.82%, the difference was significant for the parameters BOD and BOD in anaerobic ponds. There was an increase in sludge generation of approximately 16% in the receiving anaerobic pond and only 2.3% in the control. As for the scum, the average removal was approximately 450 L in the receiving anaerobic pond and only 100 L in the control. The results showed no effect of the co-treatment on the quality of treated sewage or in the operation and maintenance of the WWTP. Furthermore, systems formed by an anaerobic pond followed by facultative aerated, operating under the same conditions that Anápolis WWTP can be used for co-treatment of waste from cesspools and septic tanks / O estudo teve como objetivo avaliar os impactos da codisposição de resíduos de fossas e tanques sépticos em sistemas de lagoas anaeróbias seguidas de facultativas aeradas. A ETE estudada é composta por dois módulos idênticos de lagoas anaeróbias seguidas de facultativas aeradas, porém apenas um deles recebeu os resíduos. Ao passar por um cesto retentor de sólidos grosseiros, os mesmos foram conduzidos diretamente ao módulo receptor de lagoas. A pesquisa foi dividida em três etapas; primeiramente foi avaliado o sistema recebendo os resíduos em ambos os módulos de lagoas, com taxa de aplicação volumétrica (TAV) de 0,33%, posteriormente, a lagoa receptora recebeu todo o volume de resíduos descartado na ETE (TAV = 1,2%), por fim, a lagoa receptora foi operada com a capacidade máxima de carga orgânica e TAV de 0,83%. Amostras provenientes de diferentes caminhões limpa-fossa foram coletadas e analisadas. Realizou-se a batimetria do lodo depositado nas lagoas anaeróbias antes e depois do isolamento dos módulos. A escuma formada na superfície das lagoas anaeróbias foi removida e quantificada. Inicialmente, coletou-se amostras simples do afluente e efluente das lagoas anaeróbias e facultativas aeradas em uma frequência semanal, posteriormente, quando o módulo receptor passou a receber o dobro de vazão, as coletas foram realizadas duas vezes na semana. Foram avaliados os parâmetros de DBO, DQO, Escherichia coli, pH, óleos e graxas, fósforo total, nitrogênio amoniacal, sólidos suspensos, sólidos sedimentáveis. Os dados de caracterização qualitativa dos resíduos de fossas e tanques sépticos foram submetidos à estatística descritiva, enquanto os referentes ao efluente das lagoas foram analisados pela ferramenta estatística teste t. Os resultados indicaram que as características dos resíduos estão na faixa encontrada por outros autores, tanto na literatura nacional, quanto internacional. Foi evidenciado impacto negativo no efluente da lagoa anaeróbia receptora somente para os parâmetros nitrogênio amoniacal e sólidos sedimentáveis com a TAR de 1,2%, entretanto, com a taxa de 0,82%, observou-se diferença significativa para os parâmetros DBO e DBO nas lagoas anaeróbias. Notou-se aumento na geração de lodo de aproximadamente 16% na lagoa anaeróbia receptora e de apenas 2,3% na testemunha. Quanto a escuma, a remoção média foi de aproximadamente 450 L na lagoa anaeróbia receptora e de apenas 100 L na testemunha. Os resultados mostraram que a codisposição não interferiu na qualidade do esgoto tratado nem na operação e manutenção da ETE. Além do mais, sistemas formados por lagoa anaeróbia, seguida de facultativa aerada, operando nas mesmas condições que a ETE - Anápolis, podem ser utilizadas para a codisposição de resíduos provenientes de fossa e tanques sépticos.
172

Desinfecção de águas naturais por radiação solar utilizando os bioindicadores : Escherichia coli e Clostridium perfringens / Water solar disinfection using Escherichia coli and Clostridium perfringens as bioindicators

MORGADO, Waleska Fernanda Ferreira 25 August 2008 (has links)
Made available in DSpace on 2014-07-29T15:01:41Z (GMT). No. of bitstreams: 1 Dissertacao Waleska Fernanda F Morgado.pdf: 1282396 bytes, checksum: 4ca186add1105f1358d9922c71f2b024 (MD5) Previous issue date: 2008-08-25 / Latin-American countries are facing serious problems related to waterborne diseases due to the lack of basic sanitation, affecting in particular those people living in small and rural communities. Solar radiation for water disinfection, SODIS, seems a promising process for small communities since it does not require electric energy and it has low cost and easy operation. This work aimed to evaluate the inactivation of the pathogens Escherichia coli and Clostridium perfringens by SODIS in the Center-West region of Brazil, Goiânia-GO. The Colilert® and multiple tubes (NMP/100 mL) were used to determine the Escherichia coli and the Clostridium perfringens bacterias, respectively. The inactivation and the re-growth of these bioindicators, the physico-chemical parameters of the raw and disinfected waters were the main focus of this work. Raw water was collected from a well located at the Civil Engineering School (EEC) of Federal University of Goiás (UFG) and it was inoculated apart using pre-determined concentrations of these bio-indicators. Samples were put in transparent PET bottles with capacity of 2L and left under sunlight exposure between 9am and 3pm. Samples were collected and analyzed in the laboratory after 0, 2, 4 and 6 hours of exposure. The work was divided into two phases: the first evaluate the effect of the use of two water volumes (1.5 L and 2 L) on the pathogen inactivation. In addition, the re-growth of these pathogens in the PET bottles after 3 storage days at ambient temperature was also investigated. In the second phase, PET bottles containing 1.5 L of contaminated water were exposed to sunlight radiation with and without solar reflectors. The results showed that there was a small difference (0,25-Log to Clostridium perfringens and 0,5-Log to Escherichia coli) in the inactivation of both bioindicators between the two volumes evaluated in the first phase. The use of the solar reflector did not improve the inactivation of the Clostridium perfringens and their re-growth was proportional to the final concentration after 6 hours of sunlight exposure. / Os países latino-americanos enfrentam sérios problemas com a alta incidência de doenças relacionadas com a falta de saneamento básico, sendo mais afetadas as populações que vivem em localidades pobres, periféricas e em zonas rurais. A utilização da radiação solar no processo de desinfecção de água, SODIS, é introduzida nesse contexto como uma alternativa de desinfecção da água independente de insumos, que funciona sem fornecimento de energia elétrica, baixo custo e de fácil operação em comunidades pequenas. Este trabalho teve por objetivo avaliar a inativação dos patógenos Escherichia coli e o Clostridium perfringens através da SODIS na região Centro-Oeste do Brasil, na cidade de Goiânia GO. Para a determinação das bactérias Escherichia coli e Clostridium perfringens foi utilizado os métodos Colilert® e tubos múltiplos (NMP/100 mL), respectivamente. A inativação e o recrescimento destes bioindicadores, a análise dos parâmetros físico-químicos da água bruta e da água desinfetada pela SODIS foram os enfoques principais deste estudo. Água bruta foi coletada de um poço raso da Escola de Engenharia Civil (EEC) da Universidade Federal de Goiás (UFG) e inoculada com concentrações determinadas dos bioindicadores, separadamente, acondicionadas em garrafas de PET e expostas ao sol pelo período das 09:00 às 15:00 horas. Amostras de água foram coletadas e analisadas em laboratório após os tempos de exposição de 0, 2, 4 e 6 horas. O trabalho experimental foi dividido em duas etapas, a primeira considerou a diferença de volumes nas garrafas, 1,5 L e 2 L, para investigar o efeito das concentrações de oxigênio, a verificação do recrescimento após 3 dias de armazenamento na própria garrafa de PET em temperatura ambiente e a avaliação da água bruta antes e após a SODIS. Na segunda etapa, garrafas com volume padrão de 1,5 L foram usadas em combinação com e sem concentrador solar. Os resultados mostraram que houve uma pequena diferença, (0,25-Log para Clostridium perfringens e 0,5-Log Escherichia coli) nas inativações bacterianas em relação aos diferentes volumes, sendo maiores nas garrafas de 1,5 L para ambos os bioindicadores na etapa 1. O uso do concentrador solar não apresentou melhoria no processo em relação ao Clostridium perfringens e o recrescimento foi proporcional à concentração final dos bioindicadores após as 6 horas de exposição.
173

Estudo da aplicação do resíduo de decantador de ETA como auxiliar de floculação no tratamento de água / Study of the application of decanters waste of WTP as an aid of flocculation of water treatment

SOUZA, Leonora Milagre de 21 June 2011 (has links)
Made available in DSpace on 2014-07-29T15:01:47Z (GMT). No. of bitstreams: 1 Dissertacao _Leonora Milagre de Souza.pdf: 965865 bytes, checksum: e8839b11b69dccbdd9fd61b7554b691b (MD5) Previous issue date: 2011-06-21 / The residue generated in Water Treatment Plant (WTP) are derived from different stages of water treatment, especially the discharge of decanters. The most common practice in Brazil is the residue disposal directly into rivers, causing negative impacts to the environment. In general, the WTP have difficulties in managing the residue because the high costs of transportation and disposal, the steady increase in the consumption of chemicals, among other complicating factors. Aiming to reduce the coagulant used in the process and improving the characteristics of the residues for the outflow, this research examined the effects of biosolids application decanter of WTP in the processes of coagulation, flocculation and sedimentation of water treatment. Through laboratory tests, using Jar Test, there were three series of tests, each one using gross water with distinct turbidity. In these trials were used differents dosages of aluminum sulfate and applied to WTP samples with different concentrations of total solids suspended (TSS). After the Jar Test, the decanted water was characterized as turbidity and color, solids and coliforms were not found significant changes in their quality. For most situations, the residue application in treatment has reduced the coagulant in the range 50% to 60%. The increased turbidity of gross water allowed the application of more concentrated residue without reducing the efficiency of treatment in terms of turbidity removal. Regarding the sedimented material in the Jar Test, the decreasing of the dosage of coagulant favored the reduction of the occupied volume by the material, independent of the concentration of residue applied. The specific resistance of sedimented material was higher when compared to the situation without the application in virtually all studied situations. For water with 100 NTU and implementation of residue greater than 7.500 mg/L, and water with 210 NTU and residue less than 8.600 mg/L there was improvement in the sedimentability. The dewatering ability of the sediments by centrifugation was also improved with the application of the residue with 3.642 mg/L and 75% of the coagulant, and 7.500 mg/L using 50% of coagulant. The chemical conditioning by nonionic polyelectrolyte did not improved in the dewatering of sedimented material, but in improving water quality supernatant. Based on this study it was noticed that the application of WTP residue in water treatment was satisfactory as for the analyzed parameters, considering the dosage of coagulant used and the residue applied. / Os resíduos gerados nas Estações de Tratamento de Água (ETAs) são decorrentes das diversas etapas do tratamento da água, em especial da descarga de decantadores. A prática mais comum no Brasil de disposição desse resíduo é diretamente em corpos hídricos, podendo causar impactos negativos ao meio ambiente. Em geral, as ETAs apresentam dificuldades no gerenciamento dos resíduos devido os altos custos com transporte e disposição, o aumento constante no consumo de produtos químicos, dentre outros complicadores. Visando a redução de coagulante utilizado no processo e a melhoria das características desse resíduo para o deságue, a presente pesquisa analisou os efeitos da aplicação do resíduo de decantador de Estação de Tratamento de ETA (ETA) nos processos de coagulação, floculação e sedimentação do tratamento de água. Por meio de ensaios laboratoriais, utilizando Jar Test, foram realizadas três séries de ensaios, cada uma utilizando água bruta com turbidez distinta. Nesses ensaios foram empregadas dosagens variadas de sulfato de alumínio e aplicadas amostras de resíduo da ETA com concentrações de sólidos suspensos totais (SST) diferentes. Após a realização dos ensaios de Jar Test, a água decantada foi caracterizada quanto à turbidez, cor aparente, concentração de sólidos e coliformes, não sendo verificadas alterações significativas em sua qualidade. Para a maioria das situações, a aplicação do resíduo no tratamento possibilitou a redução de coagulante na faixa de 50% a 60%. O aumento da turbidez da água bruta permitiu a aplicação do resíduo mais concentrado, sem reduzir a eficiência do tratamento quanto a remoção de turbidez. Com relação ao material sedimentado gerado nos ensaios de Jar Test, a redução da dosagem de coagulante favoreceu a redução do volume ocupado pelo material, independente da concentração de resíduo aplicado. A resistência específica do material sedimentado foi maior se comparada à situação sem aplicação do resíduo, em praticamente todas as situações estudadas. Para a água com 100 UNT e aplicação do resíduo maior que 7.500 mg/L, e água com 210 UNT e resíduo menor que 8.600 mg/L houve melhora na sedimentabilidade. O deságue do material sedimentado por meio de centrifugação também melhorou com a aplicação dos resíduos com 3.642 mg/L e 75% de coagulante, e 7.500 mg/L utilizando 50% de coagulante. O condicionamento químico por meio de polieletrólito não iônico não auxiliou no desaguamento do material sedimentado, e sim na melhoria da qualidade da água sobrenadante. Baseado neste estudo percebeu-se que a aplicação do resíduo da ETA no tratamento de água foi satisfatória quanto aos parâmetros analisados, devendo ser levada em consideração a dosagem de coagulante empregada e a concentração do resíduo aplicado.
174

AvaliaÃÃo do Processo de DesinfecÃÃo Solar (SODIS) e de sua Viabilidade Social no Estado do Cearà / Solar Disinfection Evaluation and its Social Viability at State of CearÃ, Brazil

Marcio Pessoa Botto 14 August 2006 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Apesar da importÃncia do saneamento ambiental para o bem-estar do homem e para a conservaÃÃo dos recursos naturais, uma grande parcela da populaÃÃo mundial nÃo tem acesso aos serviÃos bÃsicos de saneamento. Uma tÃcnica caseira que vem sendo estudada e aplicada em paÃses em desenvolvimento, como uma tecnologia segura para o tratamento microbiolÃgico de Ãgua à a desinfecÃÃo solar, SODIS. Este mÃtodo utiliza apenas o sol e garrafas PET como insumo. Atualmente, cerca de um milhÃo de pessoas utiliza regularmente o SODIS em 20 diferentes paÃses. O presente estudo avaliou a eficiÃncia de inativaÃÃo de coliformes termotolerantes segundo o efeito da aerobiose, por meio da agitaÃÃo manual das garrafas e da utilizaÃÃo de diferentes superfÃcies de exposiÃÃo sob as condiÃÃes climÃticas do Estado do CearÃ, bem como a viabilidade social deste mÃtodo em quatro comunidades inseridas em cenÃrios distintos (rural, litorÃno e urbano). Para tanto, compararam-se amostras agitadas e nÃo agitadas, e amostras expostas sobre superfÃcies distintas: concreto pintado de branco, concreto pintado de preto, telha de barro, telha de amianto e bacias de alumÃnio. Para o estudo da viabilidade social, foram aplicados questionÃrios aos usuÃrios do mÃtodo e analisadas amostras da Ãgua bruta e tratada pelo mÃtodo SODIS. Verificou-se que apesar da agitaÃÃo aferir uma concentraÃÃo de 0,75mg/L a mais de OD nas amostras agitadas, esse efeito nÃo foi capaz de aumentar significativamente a eficiÃncia de inativaÃÃo para essas amostras. O decaimento mÃdio bacteriano das amostras agitadas foi 1,10 vezes maior comparado Ãs amostras nÃo agitadas. Os dados obtidos na etapa de superfÃcie indicaram que tambÃm nÃo hà diferenÃa significativa (teste T de Student, nivel de confianÃa 0,05) de inativaÃÃo em expor as garrafas sobre qualquer uma das superfÃcies pesquisadas. O decaimento mÃdio bacteriano foi de: 0,3049h-1, 0,2624h-1, 0,3152h-1, 0,2747h-1, 0,2874h-1, respectivamente, para as amostras sobre o concreto pintado de branco, concreto pintado de preto, telha de amianto, telha de barro e bacia de alumÃnio. A mÃxima temperatura da Ãgua foi de 44ÂC e ainda assim obteve-se mais de 99,99% de remoÃÃo de coliformes termotolerantes em todos os ensaios. Em 67% dos ensaios, o SODIS foi capaz de inativar completamente concentraÃÃes de coliformes termotolerantes acima de 105 NMP.100mL-1 durante as seis horas de exposiÃÃo. O estudo de campo mostrou que o SODIS melhorou a qualidade microbiolÃgica da Ãgua das quatro comunidades pesquisadas. No entanto, a permanÃncia e em alguns casos a proliferaÃÃo do indicador foi verificado quando os usuÃrios expuseram as garrafas em locais sombreados. O SODIS foi bem aceito nas comunidades rurais e litorÃneas, atingindo nÃveis de aceitaÃÃo acima de 45%, se comparado aos da comunidade urbana, com apenas 8%. AlÃm da grande aceitaÃÃo do mÃtodo, mais de 80% dos usuÃrios responderam que iriam continuar a usar o SODIS. / Despite the importance of sanitation for well-being of the mankind and the natural resources conservation, still today a large number of people do not have access to wastewater system neither to public water supply. One technique which has being studied and applied in developing countries as a safe household water treatment method is solar disinfection, SODIS. The only two elements demanded to this method are PET bottles and the sun. Nowadays, around one million people use SODIS regularly in 20 different countries. This study evaluated the feacal coliform bacteria inactivation efficiency according to the effect of bottlesâ agitation and the use of differents exposition surfaces under of State of Cearà climatic conditions, as well as SODIS social viability in four communities at distinct geographical location (peri-urban, rural and coastal). To achieve this, agitated and non-agitated samples and five diferrents surfaces: concrete spotted in white color, concrete spotted in black color, abobe roofing tile, asbestos roofing tile and aluminum basins were investigated. To evaluate social acceptability, questionnaires had been applied to all users SODIS and raw water and treated water by SODIS were analyzed. It was verified that despite the agitation surveying a concentration more than 0,75mg/L of OD in the agitated samples, this effect was not capable to increase significantly the inactivation efficiency in these samples. The mean decay constant for bacterial population in agitated bottles was found to be a factor of 1.10 higher than in non-agitated bottles. The surface investigation indicated that no significant difference (paired StudentÂs T-test at P=0,05 significance level of log10 transformed data) in inactivating feacal coliforms by exposing the bottles over the five surfaces examined were observed. The mean decay constant for bacterial population was: 0,3049h-1, 0,2624h-1, 0,3152h-1, 0,2747h-1, 0,2874h-1, respectively for the sample exposed over concrete spotted in white color, concrete spotted in black color, abobe roofing tile, asbestos roofing tile and aluminum basins. The maximum water temperature reached was 44ÂC and still thus, it was obtained reduction more than 99.99% of feacal coliforms. In 67% of the assays, SODIS was capable to completely inactivate concentrations of feacal coliforms above 105 NMP.100mL-1 within six hours of exposition. The field study had shown that SODIS improved the microbiological water quality in the four communities. However, the permanence and in some cases the increase of feacal coliforms was verified when the users exposed the bottles in shaded areas. SODIS was well received in rural and coastal communities reaching acceptance levels over than 45%, compared to urban community, with only 8%. Beyond the great acceptance of the method, over 80% of the users answered that they would continue to use SODIS.
175

A Study of Brazilian Environmental Law on Municipal Solid Waste. / Um estudo da legislaÃÃo ambiental brasileira sobre resÃduos sÃlidos urbanos

Jaciara Mota Salek 17 November 2006 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / Brazilian environmental law, considered advanced and complete, is a fundamental tool for environmental protection. In Brazil, a country with a huge urban concentration where the subject of solid waste is an important challenge, it is evident the necessity of specific public policies. However, the ignorance of part of the society about the content and even the existence of legal documents that contribute to the formulation of public policies and the responsible for its application, partially explain the distance between the law and reality. The central idea of this work is to make therefore a historic summary of Brazilian environmental law. The general objective is to join the Brazilian federal law of municipal solid waste, to discuss its applicability and to contribute for a better understanding of juridical standards. As a didactic objective, an explanation about legislative process and basic ideas of juridical standards hierarchy is done, emphasizing the administrative conflict that occurs in environmental management. This conflict makes it hard to define the entities responsible for development and application of laws. It can be observed that the legislation about municipal solid waste are divided in laws, ordinances and resolutions. They are not consolidated in only one document, consequently, making difficult the normal application of lawâs standards. Therefore, it can be concluded that there is still an absence of a federal law in Brazil that deals with the safe environmentally management of municipal solid waste, allowing more legal security in acts of public and private administration. / A legislaÃÃo ambiental brasileira, considerada moderna e abrangente, à um instrumento fundamental para a proteÃÃo do meio ambiente. No Brasil, um paÃs com grande concentraÃÃo urbana, onde a questÃo dos resÃduos sÃlidos encontra-se como um importante desafio, à latente a necessidade de polÃticas pÃblicas especÃficas. Mas o desconhecimento, por parte da sociedade, do conteÃdo e atà mesmo da existÃncia de documentos legais que contribuem para a formulaÃÃo de polÃticas pÃblicas e tambÃm dos responsÃveis por sua aplicaÃÃo, explica, em parte, a distÃncia entre o que està previsto na lei e o que se opera na realidade. Comunicar Ã, pois, a idÃia central deste trabalho, que traz um resumo histÃrico da evoluÃÃo da legislaÃÃo ambiental brasileira sobre o tema e teve como objetivo geral reunir a legislaÃÃo federal brasileira, referente aos resÃduos sÃlidos urbanos, discutir a sua aplicabilidade e contribuir para um melhor entendimento das normas jurÃdicas. Foi feita tambÃm, com objetivo prioritariamente didÃtico e informativo, uma explanaÃÃo sobre o processo legislativo e as noÃÃes bÃsicas da hierarquia das normas jurÃdicas, mostrando o conflito administrativo existente na gestÃo ambiental, que dificulta a definiÃÃo das entidades da federaÃÃo â a UniÃo, os estados-membros ou os municÃpios â que sÃo responsÃveis pela elaboraÃÃo das leis e por sua aplicaÃÃo. Observou-se que o arcabouÃo legal federal da Ãrea de resÃduos sÃlidos està distribuÃdo em leis, decretos, portarias e resoluÃÃes e nÃo consolidado em um Ãnico diploma, dificultando a aplicaÃÃo das normas legais. Concluiu-se, portanto, que o Brasil ainda carece de uma lei federal que trate da gestÃo ambientalmente segura dos resÃduos sÃlidos urbanos, possibilitando maior seguranÃa jurÃdica nos atos da administraÃÃo pÃblica e privada.
176

Avaliação das interferências da disposição de resíduos de fossas e tanques sépticos em lagoas de estabilização que tratam lixiviados: estudo de caso para o aterro sanitário de Anápolis (GO) / Evaluation of septage disposal in stabilization ponds that treat landfill leachate: case of study to the Anapolis' landfill

Carrilho, Samara Monayna Alves Vasconcelos 20 March 2014 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-11-03T16:48:26Z No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-11-03T16:49:41Z (GMT) No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-11-03T16:49:41Z (GMT). No. of bitstreams: 2 Dissertação - Samara Monaya Alves Vasconcelos Carrilho - 2014.pdf: 3214681 bytes, checksum: 626e62dc42ebe671cd1d383f26938495 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-03-20 / The destination of septage has resulted in environmental and public health problems, due especially to the lack of adequate alternatives for its destination and of closer, more rigorous monitoring. The problem worsens in areas lacking sewage treatment plants, since the disposal in such systems has been the most widely used practice in the country. In this way, the current research aims to evaluate the effects of the sludge disposal in the performance, operation and maintenance of treatment plant of leachate from landfill of Anápolis (GO). The characterization of the municipality RST was also performed by analyzing of twelve composite samples, each one from five vacuum trucks. It was evaluated the system consists of two identical modules, one it was the control group and another one received the RST. This module was submitted, increasingly, to differents Rate Volumetric Application (RVA) of RTS. Thus, the study was divided into five phases, starting with RVA of 13 % up to 204 %. Various parameters (BOD, COD, pH, oil and grease, total phosphorus, ammoniacal nitrogen, suspended solids, settling solids and Escherichia coli) were analyzed for the samples from the influent and effluent of the anaerobic and facultative ponds. It was also evaluated the impact on the maintenance and operation in the system plant, by measuring the height of the sludge in anaerobic lagoon and quantification of scum formed on the surface anaerobic pond. In facultative ponds it was performed by raising the phytoplankton community, ordering to identify possible interference in the richness and abundance of algae and cyanobacteria in these ponds. The data were statistically analyzed by the Studentt test, and the results indicated that until to 18 % of RVA there were no significant changes in the quality of treated leachate (effluent of stabilization ponds). Since the RVA of 35 % was detected a significant difference in the concentration of E. coli and ammoniacal nitrogen in treated effluent (p < 0.05). At the RVA of 204% the concentration of phosphorus in the final effluent from facultative pond increased. There was an increase in sludge generation of 266% in the receiving anaerobic pond and only 38% in the control anaerobic pond. In addition, there was a thick layer of scum only on the surface of the receiving anaerobic pond. The phytoplankton community of facultative ponds was similar and presented low diversity. The Chlorella genera were dominant in both lagoons. From the results of this study, it is recommended the conjugate treatment of RFTS and leachate in stabilization ponds systems, because even applying RVA of 204%,the final effluent don’t have concentrations higher than those stipulated by CONAMA Resolution 430/2011. / A destinação dos Resíduos de Fossa e Tanque Séptico (RFTS) tem resultado em problemas ambientais e de saúde pública, devido principalmente à falta de alternativas adequadas para a destinação, e de fiscalização mais rigorosa. O problema se agrava em municípios desprovidos de estações de tratamento de esgoto, já que a disposição nesses sistemas tem sido a prática mais utilizada no país. Neste contexto, a presente pesquisa teve por finalidade avaliar as possíveis interferências da disposição dos RFTS no desempenho, operação e manutenção no sistema de tratamento de lixiviados do Aterro Sanitário de Anápolis (GO). Também foi realizada a caracterização dos RFTS do município, através da análise de doze amostras compostas, cada uma proveniente de cinco caminhões limpa-fossas. Avaliou-se o sistema composto por dois módulos idênticos, sendo um testemunho e outro receptor de RFTS. Este foi submetido, de forma crescente, a diferentes Taxas de Aplicação Volumétrica (TAV) de RFTS, iniciando com TAV de 13%, até chegar a TAV de 204%. O estudo foi executado e os parâmetros físico-químicos e microbiológicos (DBO, DQO, pH, OG, fósforo total, nitrogênio amoniacal, sólidos suspensos, sólidos sedimentáveis e Escherichia coli) de amostras simples do afluente e efluente das lagoas anaeróbias e facultativas de ambos módulos foram analisados. Nas lagoas anaeróbias verificaram-se os possíveis impactos na manutenção e operação do sistema, através da medição da altura do lodo sedimentado no fundo da lagoa e da quantificação da escuma formada em sua superfície. Nas lagoas facultativas realizou-se o levantamento da comunidade fitoplanctônica, visando identificar possíveis interferências da codisposição de RFTS na riqueza e abundância de algas e cianobactérias. Os dados obtidos foram tratados estatisticamente, através do teste t the Student, e os resultados indicaram que até a TAV de 18% não houve alterações significativas na qualidade do lixiviado tratado (efluente das lagoas de estabilização). A partir da TAV de 35% detectou-se diferença significativa na concentração de E. coli e nitrogênio amoniacal no efluente tratado (p<0,05) e para a TAV de 204% ocorreu aumento na concentração de fósforo no efluente final da lagoa facultativa receptora. Houve interferência na manutenção e operação das lagoas, com aumento de 266% na altura do lodo sedimentado da lagoa anaeróbia receptora, ao passo que na lagoa anaeróbia testemunha, o aumento foi de 38%. Densa camada de escuma formou-se apenas na superfície da lagoa anaeróbia receptora. A comunidade fitoplanctônica das lagoas facultativas apresentou baixa diversidade, com predominância de algas do gênero Chlorella. Os resultados indicaram alta variabilidade dos RFTS do município de Anápolis. A partir deste estudo, recomenda-se o tratamento conjugado de RFTS e lixiviados em sistemas de lagoas de estabilização, pois mesmo aplicando alta TAV (204%), o efluente final não contrariou o padrão de lançamento proposto pela Resolução CONAMA 430/2011.
177

Caracterização e avaliação da distribuição de sedimentos e metais em superfícies urbanas no município de Goiânia / Characterization and evaluation of the distribution of metals and sediments in urban surfaces in Goiânia

Santos, Carolina Mundim de Souza Marques dos 22 September 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-01-20T15:17:44Z No. of bitstreams: 2 Dissertação - Carolina Mundim de Souza Marques dos Santos - 2015.pdf: 2416859 bytes, checksum: a1119fdd5a8d0203e4d9b34e4d88c7e5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-21T07:32:54Z (GMT) No. of bitstreams: 2 Dissertação - Carolina Mundim de Souza Marques dos Santos - 2015.pdf: 2416859 bytes, checksum: a1119fdd5a8d0203e4d9b34e4d88c7e5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-21T07:32:54Z (GMT). No. of bitstreams: 2 Dissertação - Carolina Mundim de Souza Marques dos Santos - 2015.pdf: 2416859 bytes, checksum: a1119fdd5a8d0203e4d9b34e4d88c7e5 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-09-22 / Urban sediments are potentially polluting because of their association with pollutants such as heavy metals, which occur frequently in industrial activities, increasing the possibility of contamination of water bodies generated by urban runoff. This study aimed to evaluate the composition and the temporal and spatial distribution of sediments in the urban area in the city of Goiania, quantifying the burden and the accumulation of sediment and metals, grain size and organic / inorganic fraction in a portion of the 3 gutter roads and the ledge of a building, for five months. The data was related to the amount of rainfall, traffic flow and wind strength. To this end, three streets were selected with different flows of vehicles, classified as low, medium and high flow. The sediment samples were collected in six installments of 0.5 m2, located in the gutter of the streets during four days of each month from June to October, using the method of brushing and vacuuming, proposed by Seep and Chiew (2002). Also sediment samples were collected on the slab of a building 3.5m height from the floor, and analyzed the load and metals present in the particulate material contained in the filter of a high volume sampler particles. Screening and laser diffraction analyzes were performed to determine the particle size. They determined the concentrations of all metals analyzed by Optical Emission Spectrometry with Inductively Coupled Plasma (ICP-OES). For the determination of organic and inorganic fractions we used the method described by STANDARD METHODS (E 2540). For metals in sediment, it was found that higher concentrations are preferably in the particles <63 pm and that follow, in general, the order Al> Fe> Ca> Ti> Mg> K> In> Ba> S> P > Mn> Zn> Cu> V> Cr> Si> Sr> Pb> Ni> U> Li> Co> Mo> Be> Cd. It was not possible to clearly observe a relationship between sludge load with the intensity of wind. As for the particle size, it was possible to observe a decrease in particle size of the sediment deposited on the slab of the building, with increasing wind speed. It was also observed an inverse behavior of the collected particulate matter in the high volume sampler particles and material collected in the gutter, where, with the rainfall there was a trend in the concentration of metals and charge build-up in the gutter and decrease the filter. As for the organic and inorganic fractions, it observed that the way to greater presence of trees showed higher organic fraction, and the way the sediments have, in general, higher organic fraction of the sediments of "white". The average diameter of the particles showed an increasing trend with the rainfall, and a direct relationship with the flow of vehicles, where the route to greater flow of cars had the highest grain sizes. / Sedimentos urbanos são potencialmente poluidores devido a sua associação a poluentes como metais pesados, que se encontram frequentemente presentes em atividades industriais, aumentando a possibilidade de contaminação de corpos d’água gerada pelo escoamento superficial urbano. O presente trabalho teve por objetivo avaliar a composição e a distribuição temporal e espacial de sedimentos em área urbana do município de Goiânia, quantificando a carga e o acúmulo de sedimentos e metais, granulometria e fração orgânica/inorgânica, em uma parcela da sarjeta de 3 vias e na laje de uma edificação, por 5 meses. Os dados foram relacionados com a quantidade de precipitação, fluxo de veículos e intensidade do vento. Para tal, foram selecionadas três ruas com diferentes fluxos de veículos, classificadas como de baixo, médio e alto fluxo. As amostras de sedimento foram coletadas em seis parcelas de 0,5 m², localizadas na sarjeta das ruas durante 4 dias de cada mês, de junho a outubro, pelo método da escovação e aspiração, proposto por Vaze e Chiew (2002). Foram coletadas também amostras de sedimentos na laje de uma edificação de 3,5m de altura em relação ao pavimento, e analisadas a carga e metais presentes no material particulado contido no filtro de um amostrador de partículas de grande volume. Foram realizadas análises de peneiramento e difratometria a laser para determinação da granulometria. Foram determinadas as concentrações de todos os metais, analisadas por Espectrometria de Emissão Óptica com Plasma Indutivamente Acoplado (ICP-OES). Para a determinação da fração orgânica e inorgânica foi utilizado o método descrito pelo STANDART METHODS (2540 E). Os resultados das análises de concentrações de metais, granulometria e fração orgânica/inorgânica foram comparadas com os resultados das amostras de “branco” de cada ponto. Os resultados mostram que a carga de sedimentos tem uma relação inversa com a ocorrência/intensidade de precipitação e com o fluxo de veículos. Para os metais nos sedimentos, verificou-se que as maiores concentrações estão preferencialmente nas partículas < 63 μm, e que seguem, em geral, a ordem de Al > Fe > Ca > Ti > Mg > K > Na > Ba > S > P > Mn > Zn > Cu > V > Cr > Si > Sr > Pb > Ni > U > Li > Co > Mo > Be > Cd. Não foi possível observar claramente uma relação entre carga de sedimentos com a intensidade do vento. Já quanto à granulometria, foi possível observar uma diminuição da granulometria dos sedimentos depositados na laje da edificação, com o aumento da intensidade do vento. Foi observado também um comportamento inverso do material particulado coletado no amostrador de partículas e do material coletado na sarjeta, onde, com a ocorrência de chuvas houve uma tendência de aumento da concentração de metais e acúmulo de carga na sarjeta e diminuição no filtro. Quanto à fração orgânica e inorgânica, foi possível verificar que a via com maior presença de arborização apresentou maior fração orgânica, e que os sedimentos das vias apresentam, de modo geral, maior fração orgânica que os sedimentos de “branco”. O diâmetro médio das partículas apresentou uma tendência de aumento com a ocorrência de chuvas, e uma relação direta com o fluxo de veículos, onde a via com maior fluxo de veículos apresentou as maiores granulometrias.
178

Utilização de modelo hidrodinâmico para mapeamento de áreas inundáveis / Using hydrodynamic model on flooding map

Santos, Kamila Almeida dos 10 December 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-01-27T17:33:00Z No. of bitstreams: 2 Dissertação - Kamila Almeida dos Santos - 2015.pdf: 15571589 bytes, checksum: 4409744d6740773c19322b95c96e75cd (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-28T11:52:55Z (GMT) No. of bitstreams: 2 Dissertação - Kamila Almeida dos Santos - 2015.pdf: 15571589 bytes, checksum: 4409744d6740773c19322b95c96e75cd (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-28T11:52:55Z (GMT). No. of bitstreams: 2 Dissertação - Kamila Almeida dos Santos - 2015.pdf: 15571589 bytes, checksum: 4409744d6740773c19322b95c96e75cd (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-12-10 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The urbanization issues is taking place in Brazilian cities has proved disorganized and thus the floods are becoming a recurring phenomenon. The growth of waterproofing in urban land decreases the amount of infiltrated water in the soil during the rainy season, the rivers might otherwise not conform the water demand in the channels in addition to receive a lot of water runoff In this context the hydrodynamic modeling is an important tool to assess the drainage systems and predict the effects of flooding. This study was applied to the watershed of Ribeirão Anicuns in Goiania, where a considerable part of the basin is in an urban area. Using the hydrodynamic model HECRAS were created various flood scenarios with return periods of 15, 25, 50 and 100 years for the project rainfall; there was aid of a geographic information system, using ArcMap 10.0 to the high-resolution orthophoto city and DEM made from airborne laser scanner, with this material extracted the geometry of the basin. In hydrodynamic modeling crafted the model was run in unsteady flow considering the full Saint Venant equation. In addition to the hydrodynamic modeling was carried out a simulation on the INPE simplified model called HAND, which turned out to be an inexpensive tool, easily accessible and with quality results. With the results obtained (flood hydrograph and flood patches concerning the different return times) flood areas were shown in different scenarios created, and you can compare them. The results showed that the flood spot along the basin have become significantly larger as the return periods grow. In urbanized streams were no major changes than the changes that occurred in streams away from the urban area. Streams that are outside the urbanized area focuses on the alert, they are natural streams and showed that will not support the volume of water resulting from this work. / O processo de urbanização que está ocorrendo nas cidades brasileiras tem se mostrado desorganizado e com isso as inundações estão se tornando um fenômeno recorrente. O crescimento da impermeabilização no solo urbano diminui a quantidade de água infiltrada no solo durante o período de chuva, os córregos não conseguem suprir a demanda da água nos canais, além de receber do escoamento superficial uma grande quantidade. Nesse contexto a modelagem hidrodinâmica é uma ferramenta importante para avaliar os sistemas de drenagens e prever os efeitos da inundação. Dessa forma o presente trabalho foi aplicado na bacia hidrográfica do Ribeirão Anicuns, no município de Goiânia, onde uma parte considerável da bacia se encontra em área urbanizada. Utilizando o modelo hidrodinâmico HEC-RAS foram criados vários cenários de inundação com os tempos de retorno de 15, 25, 50 e 100 anos para a chuva de projeto; houve auxílio de um Sistema de Informações Geográficas, utilizando o programa ArcMap 10.0 a ortofoto do município de alta resolução e o MDT feito a partir de laser scanner aerotransportado, com esse material se extraiu a geometria da bacia hidrográfica. Na modelagem hidrodinâmica trabalhada o modelo foi executardo no regime não permanente, considerando a equação de Saint Venant completa. Além da modelagem hidrodinâmica foi realizada uma simulação no modelo simplificado HAND do INPE, onde se mostrou ser uma ferramenta barata, de fácil acesso e com resultados de qualidade. Com os resultados obtidos (hidrogramas de cheia e manchas de inundação referente aos diferentes tempos de retorno) foram mostradas áreas de inundação nos diferentes cenários criados, sendo possível compara-los. Os resultados mostraram que a mancha de inundação ao longo da bacia se tornaram significativamente maiores a medida que os tempos de retorno cresciam. Nos córregos urbanizados houve mudanças maiores do que as mudanças que ocorreram nos córregos afastados do perímetro urbano. Nos córregos que estão fora da área urbanizada foca o alerta, são córregos naturais e mostraram que não suportarão o volume de água resultante deste trabalho.
179

Diagnóstico do estresse hídrico na bacia hidrográfica do Ribeirão João Leite / Diagnosis of water stress in hydrografic basin of João Leite Stream River

Keller, Patrícia Pereira Ribeiro 21 September 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-01-28T13:57:22Z No. of bitstreams: 2 Dissertação - Patrícia Pereira Ribeiro Keller - 2015.pdf: 8454284 bytes, checksum: d5e4ec0ee26ea90a9344aa5157836221 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-01-29T11:23:02Z (GMT) No. of bitstreams: 2 Dissertação - Patrícia Pereira Ribeiro Keller - 2015.pdf: 8454284 bytes, checksum: d5e4ec0ee26ea90a9344aa5157836221 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-01-29T11:23:02Z (GMT). No. of bitstreams: 2 Dissertação - Patrícia Pereira Ribeiro Keller - 2015.pdf: 8454284 bytes, checksum: d5e4ec0ee26ea90a9344aa5157836221 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-09-21 / Fundação de Amparo à Pesquisa do Estado de Goiás - FAPEG / The survey was developed with the objective of diagnosis of water stress in the catchment area of the hydrografic basin João Leite River, whereas seasonal aspects and the water regime (lotic system and still water system). Historic survey was conducted of the anthropogenic activities (industry, commerce, farmers, vegetable and mineral extraction) inserted into the catchment area of João Leite River. Following, he proceeded historical survey (2012 and 2013) of physico-chemical parameters (ambientte temperature, water temperature, turbidity, pH, nitrogen series, total phosphorus, dissolved oxygen - OD, biochemical demand of oxigênico - DBO, total dissolved solids - STD) and bacterial (Escherichia coli), resulting in the calculation of the Water Quality Index (IQA) in eleven (11) sampling points (Reservoir João Leite River, João Leite River, Bandeira Stream, Jenipapo Stream, Jurubatuba Stream, Rosa Stream, Descoberto Stream, Maria Paula Stream, Posse Stream, Mata Pasto Stream, Pedras Stream). It was found that five (5) sampling points highlighted by the lower IQA (Jurubatuba Stream - IQA 58.81; João Leite River - IQA 61.50; Bandeira Stream - IQA 63.41; Jenipapo Stream - IQA 65.22 ) or environmental significance in the Reservoir João Leite River - IQA 75.12 Subsequently, these five (5) points were monitored every two months in 2014 (3 collections in rainy season and 3 collections in dry season) analyzing 100 ( one hundred) parameters: 6 physical parameter (water temperature, transparency, quota, turbidity, apparent color and true), 89 chemical parameter (43 Organic 23 metals, caffeine, total solids, total nitrogen, pH, conductivity, STD, calcium, magnesium, chloride, nitrate, nitrite, ammonia, sulphate, total organic carbon, alkalinity, hardness, consumed oxygen, OD, DBO, chemical oxygen demand, surfactant, total iron and carbon dioxide) and 5 biological parameter (total coliforms, Escherichia coli, clorophyll- a, pheophytin and phytoplankton). The annual average of the data obtained showed the Water Quality Index 65.80 (good), Trophic State Index 52.93 (mesotrophic) and Community Index Phytoplankton 2.20 (good). Caffeine was quantified (0.315 mg L-1 to 1.512 mg L -1) at all sampling sites in the basin indicating contamination by domestic sewage. The present study demonstrated a resilient bowl with the presence of stress factors: micropollutants (demeton, atrazine, glyphosate, malathion, metolachlor, carbon tetrachloride, xylene, dichloromethane, dichloroethene, toluene), trace elements (As, Hg, Sb, Se, Cu , Fe, Al, Cr, Zn, In, Cd, Co, B, Mn, Li, Ag, Be, V, Ni, U, Ba, Pb), pathogenic organisms (Escherichia coli, Microcystis sp.) and first-order impacts (deforestation, presence of effluents and solid wastes) related to anthropogenic activities developed in the watershed region of João Leite River. / A pesquisa foi desenvolvida com objetivo de realizar o diagnóstico do estresse hídrico na bacia hidrográfica do Ribeirão João Leite, considerando aspectos sazonais e o regime hídrico (sistema lótico e sistema lêntico). Foi realizado levantamento histórico das atividades antrópicas (indústria, comércio, produtor rural, extração vegetal e mineral) inseridas na área da bacia hidrográfica do Ribeirão João Leite. Seguindo, procedeu-se levantamento histórico (2012 e 2013) de parâmetros físico-químicos (temperatura ambientte, temperatura da água, turbidez, pH, série nitrogenada, fósforo total, oxigênio dissolvido – OD, demanda bioquímica de oxigênico – DBO, sólidos totais dissolvidos – STD) e bacteriológico (Escherichia coli), resultando no cálculo do Índice de Qualidade da Água (IQA) em onze (11) pontos de amostragem (Barramento do Reservatório do Ribeirão João Leite, Ribeirão João Leite, Córrego Bandeira, Córrego Jenipapo, Córrego Jurubatuba, Córrego Rosa, Córrego Descoberto, Córrego Maria Paula, Córrego Posse, Córrego Mata Pasto, Córrego Pedras) . Verificou-se que cinco (5) pontos de amostragem destacaram-se pelo menor IQA (Córrego Jurubatuba – IQA 58,81; Ribeirão João Leite – IQA 61,50; Córrego Bandeira – IQA 63,41; Córrego Jenipapo – IQA 65,22) ou pela significância ambiental ( Barramento no Reservatório do Ribeirão João Leite – IQA 75,12. Posteriormente, estes cinco (5) pontos foram monitorados bimestralmente em 2014 (3 coletas em período de chuva e 3 coletas em período de seca) analisando 100 (cem) parâmetros: 6 físicos (temperatura da água; transparência; cota; turbidez; cor aparente e verdadeira); 89 químicos (43 orgânicos, 23 metais, cafeína, sólidos totais, nitrogênio total, pH, condutividade, STD, cálcio, magnésio, cloreto, nitrato, nitrito, amônia, sulfato, carbono orgânico total, alcalinidade, dureza, oxigênio consumido, OD, DBO, demanda química de oxigênio, surfactante, ferro total e gás carbônico) e 5 biológicos (coliformes totais, Escherichia coli, clorofila-a, feofitina e fitoplâncton). A média anual dos dados obtidos evidenciou Índice de Qualidade da Água 65,80 (bom), Índice do Estado Trófico 52,93 (mesotrófico) e Índice de Comunidade Fitoplanctônica 2,20 (bom). Foi quantificada cafeína (0,315 mg.L-1 a 1,512 mg.L-1) em todos os pontos amostrados indicando contaminação na bacia por efluentes domésticos. O presente estudo demonstrou uma bacia resiliente com presença de fatores estressantes: micropoluentes (demeton, atrazina, glifosato, malation, metolacloro, tetracloreto de carbono, xileno, diclorometano, dicloroeteno, tolueno), elementos traços (As, Hg, Sb, Se, Cu, Fe, Al, Cr, Zn, Na, Cd, Co, B, Mn, Li, Ag, Be, V, Ni, U, Ba, Pb), organismos patogênicos (Escherichia coli, Microcystis sp.) e impactos de primeira ordem (desmatamento, presença de efluentes e resíduos sólidos) relacionados às atividades antrópicas desenvolvidas na região da bacia hidrográfica do Ribeirão João Leite.
180

Análise das rotas tecnológicas existentes para os resíduos sólidos urbanos no município de Cidade Ocidental/GO / Analysis of existing routes technology for solid waste in the municipality of Cidade Ocidental/GO

Colvero, Diogo Appel 30 April 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2014-11-04T10:49:17Z No. of bitstreams: 2 Dissertação - Diogo Appel Colvero - 2014.pdf: 2918191 bytes, checksum: cee2a535c176008af07f390b66b2790f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2014-11-04T14:22:28Z (GMT) No. of bitstreams: 2 Dissertação - Diogo Appel Colvero - 2014.pdf: 2918191 bytes, checksum: cee2a535c176008af07f390b66b2790f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-11-04T14:22:28Z (GMT). No. of bitstreams: 2 Dissertação - Diogo Appel Colvero - 2014.pdf: 2918191 bytes, checksum: cee2a535c176008af07f390b66b2790f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-04-30 / The treatment and final disposal of solid waste (MSW) have raised concern and been the subject of intense debate, especially after the Law nº 12.305 of 2 August of 2010 which established the National Policy of Solid Waste (BRASIL, 2010a) . This Law established that municipalities would have up to four years to give a final environmentally correct their waste, from its publication layout. However, in Goiás, only fourteen of the 246 municipalities in the state currently have a landfill licensed by the Department of the Environment and Water Resources, of Goiás State (DEWR/GO). Thinking about it, aimed a municipality in the state who possessed a system of allocation of their MSW that targets minimizing impacts to the environment. picked up Cidade Ocidental/GO, a municipality that is part of the Integrated Development Region of the Distrito Federal and Surrounding Areas (IDRSA/DF), which has two different technological routes for disposal of solid waste: the first route, part of that waste is collected selectively and sent to a central screening called Association of Workers in Recycling and Reuse of Waste (AWRRW) and; in the second route, the remaining waste is conventionally collected and sent to landfill, which is operated by a private company, with that receives not only MSW Cidade Ocidental but also of Valparaíso de Goiás/GO - neighboring municipality to the city in study - thus forming a unique system in Goiás landfill shared. This system complies with the PNRS, which suggests the formation of consortia/sharing between cities, as well as the government will prioritize resources to municipalities that seek to unite to give a destination to their MSW. The objective of this study was to evaluate the technical, economic and environmental aspects existing of technological routes MSW municipality of Cidade Ocidental. For this, we carried out desk research by collecting secondary data and primary data collection also about technological routes of MSW city in study. The first route, the selective collecting-sorting central is not shared, because covers only the municipality of Cidade Ocidental, around 33.550 people attended. The current cost to maintain this system is R$ 375,58 per ton collected . The second route, the conventional collection-landfill is shared, also attending Valparaíso de Goiás, with about 190.000 people contemplated. To collect of form conventional and dispose at the landfill, the concessionaire, which forms with prefecture of Cidade Ocidental a public-private partnership of municipalities charge R$ 156,55 per tonne. The route of selective collecting-sorting central has some problems, which if corrected, can serve as a model for other municipalities in the state. And the second route, the conventional collection-landfill, has problems in public-private partnership, because the landfill is not the infrastructure and operation under ideal conditions, besides being with the license unsuccessful operation. However, if the mismatches are corrected, the landfill shared is a viable alternative to the municipalities of the state of Goiás. / O tratamento e a disposição final adequada dos resíduos sólidos urbanos (RSU) têm gerado preocupação e sido tema de intensos debates, principalmente, após a Lei nº. 12.305 de 2 de agosto de 2010 que instituiu a Política Nacional dos Resíduos Sólidos – PNRS (BRASIL, 2010a). Esta Lei estabeleceu que os municípios teriam até quatro anos para dar uma disposição final ambientalmente correta aos seus rejeitos, a partir da sua publicação. Entretanto, em Goiás, apenas quatorze dos 246 municípios do estado possuem atualmente um aterro sanitário licenciado pela Secretaria do Meio Ambiente e dos Recursos Hídricos do Estado de Goiás (SEMARH/GO). Pensando nisso, buscou-se um município do estado que possuísse um sistema de destinação de seus RSU que visasse minimizar os impactos ao meio ambiente. Escolheu-se Cidade Ocidental/GO, um município que faz parte da Região Integrada de Desenvolvimento do Distrito Federal e Entorno (RIDE/DF), e que possui duas rotas tecnológicas distintas para destinação de seus resíduos sólidos: na primeira rota, parte desses resíduos são coletados seletivamente e encaminhados à uma central de triagem denominada Associação dos Trabalhadores em Reciclagem e Reaproveitamento de Lixo (ASLURB) e; na segunda rota, o restante dos resíduos é coletado convencionalmente e enviado para o aterro sanitário, que é operado por uma empresa privada, sendo que esse recebe não só os RSU de Cidade Ocidental mas também os de Valparaíso de Goiás/GO - município vizinho à cidade em estudo - formando assim um sistema inédito em Goiás de aterro sanitário compartilhado. Este sistema está de acordo com a PNRS, que sugere a formação de consórcios/compartilhamento entre entes federados, assim como o governo irá priorizar recursos para os municípios que buscarem se unir para dar uma destinação aos seus RSU. Objetivou-se neste estudo avaliar os aspectos técnico-econômicos e socioambientais das rotas tecnológicas existentes para os RSU do município de Cidade Ocidental. Para isso, realizou-se uma pesquisa documental por meio de coleta de dados secundários e também levantamento de dados primários acerca das rotas tecnológicas dos RSU da cidade em estudo. A primeira rota, da coleta seletiva-central de triagem não é compartilhada, pois abrange somente o município de Cidade Ocidental, em torno de 33.550 habitantes atendidos. O custo atual para a manutenção desse sistema é de R$ 375,58 por tonelada coletada. Já a segunda rota, da coleta convencional-aterro sanitário é compartilhada, atendendo também Valparaíso de Goiás, com cerca de 190.000 habitantes contemplados. Para coletar de forma convencional e dispor no aterro sanitário, a concessionária, que forma com a prefeitura de Cidade Ocidental uma parceria público-privada, cobra dos municípios R$ 156,55 por tonelada. A rota da coleta seletiva-central de triagem possui alguns problemas, que se forem corrigidos, pode servir de modelo para os demais municípios do estado. E a segunda rota, da coleta convencional-aterro sanitário, possui problemas na parceria público-privada, pois o aterro sanitário não está com a infraestrutura e operação nas condições ideais, além de estar com a licença de operação vencida. Contudo, se as inadequações forem corrigidas, o aterro sanitário compartilhado é uma alternativa viável para os municípios do estado de Goiás.

Page generated in 0.0984 seconds