• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 891
  • 470
  • 95
  • 20
  • 9
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 1536
  • 563
  • 362
  • 311
  • 246
  • 234
  • 192
  • 166
  • 155
  • 152
  • 151
  • 135
  • 131
  • 111
  • 102
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
411

Mise en place d'un réseau sans fil de capteurs déployés à Salluit

Bouchara, Syryn 21 December 2018 (has links)
Pour suivre les effets du changement climatique et aider à la compréhension et la capacité de prédiction, des capteurs ont été installés dans le nord du Québec. Salluit à Nunavik est parmi les villages où un ensemble de capteurs a été installé. Cependant, la collecte de ces données est manuellement effectuée une fois par an par des scientifiques. Étant donné l’importance de ces informations, le chantier 1.5 du projet Sentinelle Nord vise à mesurer, enregistrer, et envoyer les données en temps réel. Notre projet a d’abord pour but l’installation d’un réseau sans fil permettant aux capteurs de transmettre les données tout au long de l’année, pour anticiper les risques et dommages. La conception du projet a été lancée en 2016 et les premiers travaux ont eu lieu en été 2017. Après une collecte de données réussie pendant les premiers mois suivants l’installation, des problèmes de réseau LTE sont survenus. La connexion LTE n’étant point fiable, les capteurs n’ont été visibles de l’université qu’entre 5 et 9% du temps, avant une perte totale du signal LTE à partir du mois de janvier 2017. Les conditions environnementales et météorologiques de la région ont confirmé les défis rencontrés de tels systèmes de collecte de données sans fil. Dans ce mémoire, nous détaillons les étapes prises pour déployer un tel réseau de capteurs dans des conditions extrêmes et inconnues. Nous expliquons aussi les défis, les problèmes et les limitations rencontrés lors du projet et donnons des recommandations et améliorations pour le futur. / To monitor the effects of climate change and to help the understanding and predictability, sensors have been installed in northern Québec. Salluit in Nunavik is among the villages of which a set of sensors has been installed. However, the collection of this data is manually done once a year by scientists. Given the importance of this information, Sentinel North project site 1.5 aims to measure, record, and send data in real time. Our project is primarily aimed at installing a wireless network that allows sensors to transmit data throughout the year, to anticipate risks and damages. The project design was launched in 2016, and the first work took place in summer 2017. After a successful data collection during the first months after installation, LTE network problems have occurred. Since the LTE connection is not reliable, the sensors were only visible from the university between 5% and 9% of the time, before a total loss of the LTE signal starting in January 2017. Environmental and meteorological conditions of the region have confirmed the challenges faced by such a system of wireless data collection. In this thesis, we detail the steps taken to deploy such a sensor network under extreme and unknown conditions. We also explain the challenges, problems and limitations encountered during the project and give recommendations and improvement for the future.
412

L'EcoChip : une plate-forme de capteurs sans fil pour la surveillance bio-environnementale

Sylvain, Matthieu 08 November 2019 (has links)
Le système proposé dans le cadre de ce travail est une plate-forme de capteurs sans fil permettant de mesurer la croissance de cultures de micro-organismes dans leur habitat naturel tout en effectuant diverses mesures environnementales. L’évaluation de la croissance des micro-organismes dans les 96 puits individuels du système est réalisée à l’aide d’un système de mesure d’impédance puisqu’il est possible de relier l’impédance d’une colonie de microorganismes à sa population en fonction du temps. Ces différentes informations sont très utiles afin d’évaluer l’état de santé d’un milieu donné et en particulier d’un milieu nordique pour ce projet. Les mesures d’impédance effectuées permettent d’identifier les puits où une croissance s’est produit et donc de les isoler plus facilement pour analyse future, ce qui simplifie le processus. Ce système effectue des mesures à intervalles régulier et peut transmettre ces mesures par un système de communication sans fil à un récepteur proche en plus de sauvegarder localement les données. Le système présente une consommation électrique très faible ce qui lui permet une autonomie de plusieurs mois avec une batterie dans des régions isolées. La conception en plusieurs puits de culture permet d’isoler plusieurs échantillons et de prendre des mesures séparées sur chacun de ceux-ci. Le projet est effectué dans le cadre de la stratégie Sentinelle Nord de l’Université Laval qui vise à améliorer la compréhension de l’environnement nordique. Le système proposé est unique en son genre au moment d’écrire ce mémoire puisqu’il permet simultanément la culture de micro-organismes in situ et l’évaluation de la croissance de ces derniers. La plate-forme proposée offre ainsi plusieurs opportunités pour les chercheurs en biologie et en microbiologie d’obtenir des informations sur ces milieux isolés. Des essais sur le terrain dans la région du Nord-du-Québec à Kuujjuarapik et au Lac à l’Eau Claire ont d’ailleurs permis de valider le fonctionnement du dispositif dans les conditions d’utilisations désirées en plus de démontrer, suite à une analyse du contenu des puits de culture, qu’il est possible de faire prospérer des micro-organismes dans ces derniers. / The proposed system consist of a wireless multi-sensors platform that can measure the growth of multiples microorganism populations inside their natural habitat while also measuring various environmental parameters. An impedance measuring circuit is used to evaluate the growth of the microorganisms inside the 96 culture wells of the EcoChip. This method is used since the impedance of these colonies is directly related to the number of microorganisms in the growth medium. These impedance measurements over time are then used to evaluate if microbial growth is normal and this can be used to give an idea of the overall health state of a given environment, which for this project is a nordic one. These impedance measurements are also used to produce growth curves that can be used to isolate wells inside which there was an increase in microorganism concentration and then easily screen them for further analyses. The designed system is programmed to scan the culture wells at regular intervals and to transmit the results to a nearby base station via a wireless link. These data are also saved on the on-board memory to ensure that they can be recovered later when there are no nearby receivers. The multi-well conception of the system also allows to isolate multiple samples and to conduct individual measurements on each of them. Since the platform is autonomous and is powered with a battery, it is designed to have a very low power consumption which allows for a long lifetime while in an isolated location. This project is done as part of the Sentinel Nord Strategy of Université Laval which aims to improve our understanding of the northern environment. At the time of the redaction of this thesis, the proposed system is unique in its kind since it allows the culture of microorganisms in situ and the evaluation of the culture growth with an electronic system while in the wild. The platform offers many opportunities for scientists in biology and microbiology since it enables them to obtain information on various isolated places where environmental data and microorganism samples can be hard to get. Field tests at Kuujjuarapik and Clearwater Lake (Nord-du-Québec) with the device have proven that the system allows the growth of microorganism colonies in its wells while conducting successful impedance analyses.
413

A wireless, wearable and multimodal body-machine interface design framework for individuals with severe disabilities

Fall, Cheikh Latyr 11 July 2019 (has links)
Les technologies d’assistance jouent un rôle important dans le quotidien des personnes en situation de handicap, notamment dans l’amélioration de leur autonomie de vie. Certaines d’entre elles à l’exemple des fauteuils roulants motorisés et autres bras robotiques articulés, requièrent une interaction au moyen d’interfaces dédiées capables de traduire l’intention de l’utilisateur. Les individus dont le niveau de paralysie confère de bonnes capacités résiduelles arrivent à interagir avec les interfaces de contrôle nécessitant une intervention mécanique et un certain niveau de dextérité (joysitck, boutons de contrôle, clavier, switch, souris etc). Cependant, certains types de handicap (lésion ou malformation médullaire, paralysie cérébrale, traumatismes à la suite d’un accident, absence congénital de membres du haut du corps, etc) peuvent entraîner une perte d’autonomie des doigts, des avant-bras ou des bras, rendant impossibles le recours à ces outils de contrôle. Dès lors, il est essentiel de concevoir des solutions alternatives capables de pallier ce manque. Partout à travers le monde, des chercheurs réalisent des prouesses technologiques et conçoivent des interfaces corps-machine adaptés à des handicaps spécifiques. Certaines d’entre elles utilisent les signaux bio-physiologiques (électromyoraphie (EMG), électroencéphalographie (EEG), électrocorticographie (ECoG), électrocculographie (EOG)), image de l’activité musculaire, cérébrale et occulographique du corps humain, qu’elles traduisent en moyens de contrôle relatifs à un mouvement, une intention formulée par le cerveau, etc. D’autres se servent de capteurs d’image capable d’être robuste dans un environnement donné, pour traduire la direction du regard, la position de la tête ou l’expression faciale en vecteurs de contrôle. Bien qu’ayant fait montre de leur efficacité, ces techniques sont parfois trop coûteuses, sensibles à l’environnement dans lequel elles sont utilisés, peuvent être encombrantes et contre-intuitives, ce qui explique le gap existant entre les besoins réels, la recherche et le marché des solutions de contrôle alternatives disponibles. Ce projet propose un “framework” embarqué, permettant d’interfacer différents types de modalités de mesure des capacités résiduelles des patients, au sein d’un réseau de capteurs corporels sans-fils multimodales. Son architecture est conçue de façon à pouvoir prendre en compte différents types de handicap et octroyer une large gamme de scénarios de contrôle pouvant s’adapter facilement aux aptitudes physiques de son utilisateur. In fine, l’interface corps-machine que ce projet propose, explore des approches nouvelles, se voulant pallier aux limitations des solutions existantes et favoriser l’autonomie de vie des individus en situation de handicap. / Assistive technologies play an important role in the day-to-day lives of people with disabilities, in particular in improving their autonomy. Tools such as motorized wheelchairs, assistive robotic arms, etc, require interaction through dedicated interfaces capable of translating the user’s intention. Individuals whose level of paralysis allows good residual abilities can interact with control interfaces requiring mechanical intervention and a good level of dexterity (joysitck, control buttons, keyboard, switch, mouse etc). However, certain types of disability (spinal cord injury or malformation, cerebral palsy, trauma following an accident, congenital absence of upper body limbs, etc.) may result in loss of autonomy of the fingers, forearms or arms, making it impossible to use these control tools. Therefore, it is essential to design alternative solutions to overcome this lack. Researchers around the world are realizing technological prowess by designing body-machine interfaces adapted to specific handicaps. Some of them use bio-physiological signals (electromyography (EMG), electroencephalography (EEG), electrocorticography (ECoG), electrocculography (EOG)), images of the muscular, cerebral and occulographic activity of the human body, for translation into means of control with respect to a movement, an intention formulated by the brain, etc. Others use image sensors that can be robust in a given environment, to translate the direction of gaze, the position of the head, or facials expressions, into control vectors. Although they were proved to be efficient, these techniques are sometimes too expensive, sensitive to the environment in which they are used, can be cumbersome and counter-intuitive, which explains the gap between existing needs, research and development, and the market of commercially available alternative control solutions. This project provides a "framework" that enables the design of flexible, modular, adaptive and wearable body-machine interfaces for the severely disabled. The proposed system, which implements a wireless and multimodal body sensor network, allows for different types of modalities the measure the residual capacities of individuals with severe disabilities for translation into intuitive control commands. The architecture is designed to accommodate different types of disabilities and provide a wide range of control scenarios. Ultimately, the body-machine interface that this project proposes, explores new approaches, aiming to overcome the limitations of existing solutions and to promote the autonomy of life of individuals with disabilities.
414

A novel wireless ring-shaped multi-site pulse oximeter

Avakh Kisomi, Alireza 24 April 2018 (has links)
Ces dernières années, la supervision continue des signes vitaux des patients a été un sujet d'intérêt de plusieurs travaux de recherche surtout pour ceux qui souffrent de maladies chroniques ou qui travaillent dans des environnements hasardeux. Dans la pratique médicale moderne, le niveau d'oxygène dans le sang est un des signes vitaux primaires tels que la pression artérielle, la fréquence cardiaque, la température corporelle et le rythme respiratoire. L'oxymétrie de pouls est une technique populaire non-intrusive qui permet de diagnostiquer des problèmes liés aux systèmes respiratoire et circulatoire. Pour cette raison, elle est largement utilisée dans les soins intensifs, les salles d'opération, les soins d'urgence, la naissance et l'accouchement, les soins néonatals et pédiatriques, les études du sommeil et les soins vétérinaires. Or, pour l’oxymètre de pouls, une acquisition précise des signaux est importante pour assurer la fiabilité des mesures de la saturation d'oxygène artériel (SaO2). Dans ce cas, le positionnement des capteurs joue un rôle important car la complexité de la structure du tissu du doigt peut rendre l'effet de l'emplacement de la source lumineuse imprévisible sur la mesure du SpO2. Si tel est le cas, un faible nombre de capteurs autour du doigt pourrait perturber la trajectoire des rayons de lumière et corrompre les mesures. Les oxymètres de pouls conventionnels utilisent une pince à doigts contenant les capteurs qui utilise un seul ensemble de LED et photodétecteur (PD). En plus de l'inconvénient des pinces à doigts, le placement du capteur n'est pas corrigé et sera affecté par des artefacts de mouvement. Dans ce mémoire, nous présenterons un oxymètre qui utilise six ensembles de diodes électroluminescentes et de photo-détecteurs, répartis uniformément en anneau autour du doigt, ce qui permet d'identifier le meilleur chemin de signal, immunisant ainsi l'acquisition du signal à l'effet de position de l'anneau. En outre, pour éliminer les fils de la station de base, ce système utilise un émetteur-récepteur radio ce qui supprime les inconvénients de l'attachement. Dans cette étude de conception de preuve de concept, un prototype de cet oxymètre en anneau est réalisé avec des composants commerciaux à faible consommation de courant et le tout est montés sur une carte électronique flex-rigides qui communique avec un hôte distant par un lien sans-fil pour traiter le signal et calculer le niveau d'oxygène. / Continuous health monitoring for patients with chronic diseases or people working in high-risk environments has been an interesting topic of research in recent years. In modern medical practice, the blood oxygen level is one of the vital signs of the body alongside blood pressure, heart rate, body temperature, and breathing rate. Pulse oximeters provide early information on problems in the respiratory and circulatory systems. They are widely used in intensive care, operating rooms, emergency care, birth and delivery, neonatal and pediatric care, sleep studies, and in veterinary care. Proper signal acquisition in a pulse oximetry system is essential to monitor the arterial oxygen saturation (SaO2). Since the tissue of finger has a complicated structure, and there is a lack of detailed information on the effect of the light source and detector placement on measuring SpO2, sensor placement plays an important role in this respect. Not enough sensors placed around the finger will have an adverse effect on the light path so high signal quality may become impossible to achieve. The conventional Pulse Oximeters use a finger clip, which uses only one set of LEDs and photodetector (PD). In addition to the inconvenience of the finger clips, the placement of the sensor is not fixed and will be affected by motion artifacts. In this thesis, we present a ring-shaped oximeter that uses six sets of light emitting diodes and photodetectors, uniformly distributed around the finger to identify the best signal path, thus making the signal acquisition immune to ring position on the finger. In addition, this system uses a radio transceiver to eliminate the connection wires to a base station which removes the inconvenience of the tethering and reduce the motion artifacts. In this proof of concept study, this novel ring oximeter is implemented with commercial low power consumption off-the-shelf components mounted on a rigid-flex board that connects to a remote host for signal processing and oxygen level calculation.
415

ATSC DTV channel estimation

Song, Limeng 16 April 2018 (has links)
À l'heure actuelle, pour le développement à long terme des réseaux sans fil la modélisation et l'estimation du canal s'avèrent très importantes. L'argument qui appuie cette affirmation, c'est que nous pouvons caractériser certains canaux dune manière utile au concepteur de système. Ce document présente une étude statistique du canal sans fil pour le système de transmission à trajets multipes ATSC (Advanced Systems Committee) DTTV (Digital Terrestrial Television). Les banques de données ATSC ont été divisées en plusieurs groupes selon les secteurs de réception et autres conditions de propagation. Nous présentons ici la procédure d'évaluation et les résultats d'expériences effectuées sur des canaux fixes et mobiles comprenant les distributions du nombre de trajets multiples et l'écart-type de l'étalement du délai. Le modèle modifié de Poisson a été appliqué pour comparaison avec le modèle statistique des trajets multiples pour chaque canal. Nous décrivons également les différentes catégories d'égaliseurs du système et comparons ainsi leurs fonctions.
416

Defining graphic novels : the contentious case of wordless novels

Prévost-Levac, Caroline 01 May 2018 (has links)
Malgré la longue et riche histoire des bandes dessinées, leur définition continue de stimuler le débat parmi les experts. Ces derniers ne parviennent toujours pas à s’entendre sur la composition d’une bande dessinée, certains choisissant de mettre l’emphase sur l’usage de phylactères ou de lignes de mouvement, tandis que d’autres insistent plutôt sur la présence d’éléments à la fois graphiques et narratifs. Une définition impeccable est peut-être improbable, mais un problème mérite toutefois d’être adressé: il s’agit bien sûr de la constante exclusion des romans graphiques sans texte. Cette catégorie d’œuvres est parfois mentionnée, mais se révèle plus souvent ignorée par les experts. En effet les définitions courantes persistent à représenter les bandes dessinées comme un indéniable mélange de texte et d’images. Ce mémoire cherche donc à démontrer la nécessité de définitions plus inclusives, afin d’incorporer les romans graphiques sans texte. D’abord, en explorant l’histoire du médium et le rôle du texte dans la création et la lecture des romans graphiques, nous réfuterons les idées préconçues qui ont apporté à l’élément textuel de la bande dessinée une allure de nécessité. Puis, à travers l’analyse des romans graphiques sans texte The Arrival de Shaun Tan et The System de Peter Kuper, nous rendrons évidente la nature facultative du texte dans le processus de création d’une histoire de bande dessinée. Finalement, avec le support d’exemples provenant des romans graphiques The System de Peter Kuper et Asterios Polyp de David Mazzucchelli, nous analyserons le rôle de l’image dans le développement de la complexité narrative d’une histoire de bande dessinée, afin de prouver qu’une image n’est pas intrinsèquement plus simpliste qu’un extrait de texte. Les romans graphiques sans texte méritent tout autant l’attention académique reçue par les bandes dessinées avec texte, et devraient ainsi être reconnus dans les définitions courantes du médium. / In spite of comics’ long and rich history, their definition remains today a significant source of contention in the field. Scholars cannot seem to agree on what constitutes comics, with some of them stressing the importance of conventions such as speech balloons or motion lines, and others focusingon the pictorial and narrative elements of the form. A perfect definition may be impossible, but one issue that needs tobe addressed is the current exclusion of wordless graphic novels. While occasionally acknowledged, these works remain mainly ignored, as most working definitions present comics as a combination of text and image. This thesis intends to show that there is a need for more inclusive definitions of the medium, in order to incorporate wordless graphic novels. By first exploring the wordless ancestry of the medium and the role of text in creating and reading graphic novels, this thesis refutes the foundationally baseless assumptions about the form that have made text so widely accepted as a defining element. Then, through an analysis of Shaun Tan’s The Arrival and Peter Kuper’s The System, both of which are wordless graphic novels, this thesis demonstrates the superfluous nature of text when it comes to narrative in this medium. Finally, through readings of Peter Kuper’s The System and David Mazzucchelli’s Asterios Polyp, the thesis considers the contribution of the image to the complexity of graphic novels with and without text, in order to prove that images are not more simplistic in nature than text. The case is thereby made that wordless novels are as worthy of academic attention as graphic novels with text, and deserve acknowledgement in definitions of the medium.
417

Development of a GIS-based method for sensor network deployment and coverage optimization

Argany, Meysam 23 April 2018 (has links)
Au cours des dernières années, les réseaux de capteurs ont été de plus en plus utilisés dans différents contextes d’application allant de la surveillance de l’environnement au suivi des objets en mouvement, au développement des villes intelligentes et aux systèmes de transport intelligent, etc. Un réseau de capteurs est généralement constitué de nombreux dispositifs sans fil déployés dans une région d'intérêt. Une question fondamentale dans un réseau de capteurs est l'optimisation de sa couverture spatiale. La complexité de l'environnement de détection avec la présence de divers obstacles empêche la couverture optimale de plusieurs zones. Par conséquent, la position du capteur affecte la façon dont une région est couverte ainsi que le coût de construction du réseau. Pour un déploiement efficace d'un réseau de capteurs, plusieurs algorithmes d'optimisation ont été développés et appliqués au cours des dernières années. La plupart de ces algorithmes reposent souvent sur des modèles de capteurs et de réseaux simplifiés. En outre, ils ne considèrent pas certaines informations spatiales de l'environnement comme les modèles numériques de terrain, les infrastructures construites humaines et la présence de divers obstacles dans le processus d'optimisation. L'objectif global de cette thèse est d'améliorer les processus de déploiement des capteurs en intégrant des informations et des connaissances géospatiales dans les algorithmes d'optimisation. Pour ce faire, trois objectifs spécifiques sont définis. Tout d'abord, un cadre conceptuel est développé pour l'intégration de l'information contextuelle dans les processus de déploiement des réseaux de capteurs. Ensuite, sur la base du cadre proposé, un algorithme d'optimisation sensible au contexte local est développé. L'approche élargie est un algorithme local générique pour le déploiement du capteur qui a la capacité de prendre en considération de l'information spatiale, temporelle et thématique dans différents contextes d'applications. Ensuite, l'analyse de l'évaluation de la précision et de la propagation d'erreurs est effectuée afin de déterminer l'impact de l'exactitude des informations contextuelles sur la méthode d'optimisation du réseau de capteurs proposée. Dans cette thèse, l'information contextuelle a été intégrée aux méthodes d'optimisation locales pour le déploiement de réseaux de capteurs. L'algorithme développé est basé sur le diagramme de Voronoï pour la modélisation et la représentation de la structure géométrique des réseaux de capteurs. Dans l'approche proposée, les capteurs change leur emplacement en fonction des informations contextuelles locales (l'environnement physique, les informations de réseau et les caractéristiques des capteurs) visant à améliorer la couverture du réseau. La méthode proposée est implémentée dans MATLAB et est testée avec plusieurs jeux de données obtenus à partir des bases de données spatiales de la ville de Québec. Les résultats obtenus à partir de différentes études de cas montrent l'efficacité de notre approche. / In recent years, sensor networks have been increasingly used for different applications ranging from environmental monitoring, tracking of moving objects, development of smart cities and smart transportation system, etc. A sensor network usually consists of numerous wireless devices deployed in a region of interest. A fundamental issue in a sensor network is the optimization of its spatial coverage. The complexity of the sensing environment with the presence of diverse obstacles results in several uncovered areas. Consequently, sensor placement affects how well a region is covered by sensors as well as the cost for constructing the network. For efficient deployment of a sensor network, several optimization algorithms are developed and applied in recent years. Most of these algorithms often rely on oversimplified sensor and network models. In addition, they do not consider spatial environmental information such as terrain models, human built infrastructures, and the presence of diverse obstacles in the optimization process. The global objective of this thesis is to improve sensor deployment processes by integrating geospatial information and knowledge in optimization algorithms. To achieve this objective three specific objectives are defined. First, a conceptual framework is developed for the integration of contextual information in sensor network deployment processes. Then, a local context-aware optimization algorithm is developed based on the proposed framework. The extended approach is a generic local algorithm for sensor deployment, which accepts spatial, temporal, and thematic contextual information in different situations. Next, an accuracy assessment and error propagation analysis is conducted to determine the impact of the accuracy of contextual information on the proposed sensor network optimization method. In this thesis, the contextual information has been integrated in to the local optimization methods for sensor network deployment. The extended algorithm is developed based on point Voronoi diagram in order to represent geometrical structure of sensor networks. In the proposed approach sensors change their location based on local contextual information (physical environment, network information and sensor characteristics) aiming to enhance the network coverage. The proposed method is implemented in MATLAB and tested with several data sets obtained from Quebec City spatial database. Obtained results from different case studies show the effectiveness of our approach.
418

High-performance wireless power and data transfer interface for implantable medical devices

Mirbozorgi, Seyed Abdollah 23 April 2018 (has links)
D’importants progès ont été réalisés dans le développement des systèmes biomédicaux implantables grâce aux dernières avancées de la microélectronique et des technologies sans fil. Néanmoins, ces appareils restent difficiles à commercialier. Cette situation est due particulièrement à un manque de stratégies de design capable supporter les fonctionnalités exigées, aux limites de miniaturisation, ainsi qu’au manque d’interface sans fil à haut débit fiable et faible puissance capable de connecter les implants et les périphériques externes. Le nombre de sites de stimulation et/ou d’électrodes d’enregistrement retrouvés dans les dernières interfaces cerveau-ordinateur (IMC) ne cesse de croître afin d’augmenter la précision de contrôle, et d’améliorer notre compréhension des fonctions cérébrales. Ce nombre est appelé à atteindre un millier de site à court terme, ce qui exige des débits de données atteingnant facilement les 500 Mbps. Ceci étant dit, ces travaux visent à élaborer de nouvelles stratégies innovantes de conception de dispositifs biomédicaux implantables afin de repousser les limites mentionnées ci-dessus. On présente de nouvelles techniques faible puissance beaucoup plus performantes pour le transfert d’énergie et de données sans fil à haut débit ainsi que l’analyse et la réalisation de ces dernières grâce à des prototypes microélectroniques CMOS. Dans un premier temps, ces travaux exposent notre nouvelle structure multibobine inductive à résonance présentant une puissance sans fil distribuée uniformément pour alimenter des systèmes miniatures d’étude du cerveaux avec des models animaux en ilberté ainsi que des dispositifs médicaux implantbles sans fil qui se caractérisent par une capacité de positionnement libre. La structure propose un lien de résonance multibobines inductive, dont le résonateur principal est constitué d’une multitude de résonateurs identiques disposés dans une matrice de bobines carrées. Ces dernières sont connectées en parallèle afin de réaliser des surfaces de puissance (2D) ainsi qu’une chambre d’alimentation (3D). La chambre proposée utilise deux matrices de résonateurs de base, mises face à face et connectés en parallèle afin d’obtenir une distribution d’énergie uniforme en 3D. Chaque surface comprend neuf bobines superposées, connectées en parallèle et réailsées sur une carte de circuit imprimé deux couches FR4. La chambre dispose d’un mécanisme naturel de localisation de puissance qui facilite sa mise en oeuvre et son fonctionnement. En procédant ainsi, nous évitons la nécessité d’une détection active de l’emplacement de la charge et le contrôle d’alimentation. Notre approche permet à cette surface d’alimentation unique de fournir une efficacité de transfert de puissance (PTE) de 69% et une puissance délivrée à la charge (PDL) de 120 mW, pour une distance de séparation de 4 cm, tandis que le prototype de chambre complet fournit un PTE uniforme de 59% et un PDL de 100 mW en 3D, partout à l’intérieur de la chambre avec un volume de chambre de 27 × 27 × 16 cm3. Une étape critique avant d’utiliser un dispositif implantable chez les humains consiste à vérifier ses fonctionnalités sur des sujets animaux. Par conséquent, la chambre d’énergie sans fil conçue sera utilisée afin de caractériser les performances d’ une interface sans fil de transmisison de données dans un environnement réaliste in vivo avec positionement libre. Un émetteur-récepteur full-duplex (FDT) entièrement intégré qui se caractérise par sa faible puissance est conçu pour réaliser une interfaces bi-directionnelles (stimulation et enregistrement) avec des débits asymétriques: des taux de tramnsmission plus élevés sont nécessaires pour l’enregistrement électrophysiologique multicanal (signaux de liaison montante) alors que les taux moins élevés sont utilisés pour la stimulation (les signaux de liaison descendante). L’émetteur (TX) et le récepteur (RX) se partagent une seule antenne afin de réduire la taille de l’implant. L’émetteur utilise la radio ultra-large bande par impulsions (IR-UWB) basée sur l’approche edge combining et le RX utilise la bande ISM (Industrielle, Scientifique et Médicale) de fréquence central 2.4 GHz et la modulation on-off-keying (OOK). Une bonne isolation (> 20 dB) est obtenue entre le TX et le RX grâce à 1) la mise en forme les impulsions émises dans le spectre UWB non réglementée (3.1-7 GHz), et 2) le filtrage espace-efficace (évitant l’utilisation d’un circulateur ou d’un diplexeur) du spectre du lien de communication descendant directement au niveau de l’ amplificateur à faible bruit (LNA). L’émetteur UWB 3.1-7 GHz utilise un e modultion OOK ainsi qu’une modulation par déplacement de phase (BPSK) à seulement 10.8 pJ / bits. Le FDT proposé permet d’atteindre 500 Mbps de débit de données en lien montant et 100 Mbps de débit de données de lien descendant. Il est entièrement intégré dans un procédé TSMC CMOS 0.18 um standard et possède une taille totale de 0.8 mm2. La consommation totale d’énergie mesurée est de 10.4 mW (5 mW pour RX et 5.4 mW pour TX au taux de 500 Mbps). / In recent years, there has been major progress on implantable biomedical systems that support most of the functionalities of wireless implantable devices. Nevertheless, these devices remain mostly restricted to be commercialized, in part due to weakness of a straightforward design to support the required functionalities, limitation on miniaturization, and lack of a reliable low-power high data rate interface between implants and external devices. This research provides novel strategies on the design of implantable biomedical devices that addresses these limitations by presenting analysis and techniques for wireless power transfer and efficient data transfer. The first part of this research includes our proposed novel resonance-based multicoil inductive power link structure with uniform power distribution to wirelessly power up smart animal research systems and implanted medical devices with high power efficiency and free positioning capability. The proposed structure consists of a multicoil resonance inductive link, which primary resonator array is made of several identical resonators enclosed in a scalable array of overlapping square coils that are connected in parallel and arranged in power surface (2D) and power chamber (3D) configurations. The proposed chamber uses two arrays of primary resonators, facing each other, and connected in parallel to achieve uniform power distribution in 3D. Each surface includes 9 overlapped coils connected in parallel and implemented into two layers of FR4 printed circuit board. The chamber features a natural power localization mechanism, which simplifies its implementation and eases its operation by avoiding the need for active detection of the load location and power control mechanisms. A single power surface based on the proposed approach can provide a power transfer efficiency (PTE) of 69% and a power delivered to the load (PDL) of 120 mW, for a separation distance of 4 cm, whereas the complete chamber prototype provides a uniform PTE of 59% and a PDL of 100 mW in 3D, everywhere inside the chamber with a chamber size of 27×27×16 cm3. The second part of this research includes our proposed novel, fully-integrated, low-power fullduplex transceiver (FDT) to support bi-directional neural interfacing applications (stimulating and recording) with asymmetric data rates: higher rates are required for recording (uplink signals) than stimulation (downlink signals). The transmitter (TX) and receiver (RX) share a single antenna to reduce implant size. The TX uses impulse radio ultra-wide band (IR-UWB) based on an edge combining approach, and the RX uses a novel 2.4-GHz on-off keying (OOK) receiver. Proper isolation (> 20 dB) between the TX and RX path is implemented 1) by shaping the transmitted pulses to fall within the unregulated UWB spectrum (3.1-7 GHz), and 2) by space-efficient filtering (avoiding a circulator or diplexer) of the downlink OOK spectrum in the RX low-noise amplifier (LNA). The UWB 3.1-7 GHz transmitter using OOK and binary phase shift keying (BPSK) modulations at only 10.8 pJ/bit. The proposed FDT provides dual band 500 Mbps TX uplink data rate and 100 Mbps RX downlink data rate. It is fully integrated on standard TSMC 0.18 nm CMOS within a total size of 0.8 mm2. The total power consumption measured 10.4 mW (5 mW for RX and 5.4 mW for TX at the rate of 500 Mbps).
419

Effets du sérum lors de la culture de substituts cutanés sains et psoriasiques

Gauthier, Lydia 17 April 2018 (has links)
Le sérum ajouté aux milieux de culture est connu pour être une substance difficile à contrôler en raison de la présence de facteurs variables. Le but de cette étude était de faire varier les conditions de culture en retirant le sérum lors de la montée à l'interface air-liquide et de poursuivre les observations sur la qualité des substituts cutanés sains et psoriasiques produits par la méthode d'auto-assemblage. Les résultats histologique, macroscopique et immunohistochimique des substituts sains cultivés avec ou sans sérum ne montrent aucune différence significative. Les analyses infrarouges effectuées sur ces derniers permettent d'observer que ceux cultivés en absence de sérum possèdent une meilleure organisation lipidique au niveau de la couche cornée. Par contre, l'absorption percutanée démontre des différences au regard des propriétés physico-chimiques des molécules étudiées. De plus, les substituts conçus à partir de cellules psoriasiques affichent des résultats différents lorsque le sérum est retiré. Il semble que l'apport du sérum soit davantage important lors de l'utilisation de cellules pathologiques.
420

Conception et implémentation d'un réseau sans-fil pour la surveillance continue des signes vitaux

Elfaramawy, Tamer 25 January 2019 (has links)
Les dépenses de santé augmentent continuellement année après année et prennent une grande partie du budget d’un pays. Pendant les soins médicaux, les signes vitaux, tels que le rythme cardiaque et la respiration, sont des paramètres clés qui sont surveillés en permanence. La toux est un indicateur important de plusieurs problèmes comme la maladie pulmonaire obstructive chronique (MPOC), et c’est aussi la principale raison pour laquelle les patients consultent un médecin. En fait, c’est un mécanisme de défense pulmonaire des voies respiratoires qui permet l’expulsion de substances indésirables et irritantes. Les capteurs de corps sans fil sont de plus en plus utilisés par les cliniciens et les chercheurs, dans un large éventail d’applications telles que le sport, l’ingénierie spatiale et la médecine. La surveillance des signes vitaux en temps réel peut considérablement augmenter la précision du diagnostic et peut permettre des méthodes de guérison automatiques, par exemple, la détection et l’arrêt des crises d’épilepsie ou de narcolepsie. Les paramètres respiratoires sont essentiels en oxygénothérapie, en milieu hospitalier et en surveillance ambulatoire, tandis que l’évaluation de la sévérité de la toux est essentielle pour traiter plusieurs maladies, comme la bronchopneumopathie chronique obstructive (BPCO). Dans cette thèse, un système de surveillance respiratoire sans fil de faible puissance avec détection de la toux est présenté. Ce système utilise des capteurs multimodaux, portables et sans-fils, conçus à l’aide de composants conventionnels disponibles dans le commerce. Ces capteurs portables utilisent une unité de mesure inertielle à 9 axes de faible puissance pour mesurer la fréquence respiratoire, et un microphone MEMS pour effectuer la détection de la toux. L’architecture de chaque capteur sans fil est présentée. De plus, les résultats montrent que le capteur à petite taille de 26,67 x 65,53 mm² consomme environ 12 à 16,2 mA et peut durer au moins 6 heures avec une batterie lithium-ion miniature de 100 mA. L’unité d’acquisition, l’unité de communication sans fil et les algorithmes de traitement de données sont décrits. Les performances du réseau de capteurs sont présentées pour des tests expérimentaux en comparant avec la pléthysmographie d’inductance respiratoire. / Health care expenses are continuously increasing year after year and taking a large part of a country’s budget. During medical care, vital signs, such as heart and breathing rates, are key parameters that are continuously monitored. Coughing is a prominent indicator of several problems such as COPD, and it is also the main reason for why patients seek medical advice. In fact, it is a pulmonary defense mechanism of the respiratory tract that allows the expulsion of undesirable and irritating substances. Wireless body sensors are increasingly used by clinicians and researchers, in a wide range of applications such as sports, space engineering and medicine. Monitoring vital signs in real time can dramatically increase diagnosis accuracy and enable automatic curing procedures, e.g. detect and stop epilepsy or narcolepsy seizures. Breathing parameters are critical in oxygen therapy, hospital and ambulatory monitoring, while the assessment of cough severity is essential when dealing with several diseases, such as chronic obstructive pulmonary disease (COPD). In this thesis, a low-power wireless respiratory monitoring system with cough detection is proposed to measure the breathing rate and the frequency of coughing. This system uses wearable wireless multimodal patch sensors, designed using off the shelf components. These wearable sensors use a low-power 9-axis inertial measurement unit to measure the respiratory frequency, and a MEMs microphone to perform cough detection. The architecture of each wireless patch-sensor is presented. In fact, the results show that the small 26.67 x 65.53 mm² patch-sensor consumes around 12 to 16.2 mA, and can last at least 6 hours with a miniature 100 mA lithium ion battery. The acquisition unit, the wireless communication unit and the data processing algorithms are described. The proposed network performance is presented for experimental tests with a freely behaving user in parallel with the gold standard respiratory inductance plethysmography

Page generated in 0.0501 seconds