• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 153
  • 84
  • 78
  • 39
  • 13
  • 9
  • 9
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 467
  • 101
  • 68
  • 49
  • 49
  • 46
  • 45
  • 37
  • 34
  • 33
  • 33
  • 27
  • 26
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

The five-fold surface of the icosahedral Al←7←0Pd←2←1Mn←9 quasicrystal

Ledieu, Julian January 2001 (has links)
No description available.
222

A critical study of plastics sheet extrusion processes

Westman, K. January 1966 (has links)
No description available.
223

Simulation par CFD et mesure en ligne de la distribution des temps de séjour et la qualité de mélange dans une extrudeuse bi-vis / CFD simulation and online measurement of the residence time distribution and mixing quality ina twin- screw extruders

Zhang, Xian-Ming 10 November 2008 (has links)
Aujourd’hui le développement de nouveaux matériaux polymères ayant de bonnes propriétés repose de plus en plus sur des procédés de mélange ou de compoundage de polymères au lieu de recourir à la synthèse de nouvelles molécules. L’action du mélange peut fortement influer sur la morphologie des matériaux polymères multi-constituants. Les extrudeuses bi-vis (TSE) sont souvent utilisées comme mélangeurs/réacteurs pour des procédés de mélange, de compoundage et d’extrusion réactive. Cependant, l’étude sur la qualité du mélange dans les TSE demeure un grand défi en raison de la complexité géométrique et du caractère transitoire de l’écoulement. Cette thèse a pour objet de développer un nouvel instrument en line pour mesurer en temps réel la distribution des temps de séjour (DTS) qui caractérise la performance du mélange axial et la capacité de convoyage de différents types d’éléments de vis basées sur l’analyse de l’écoulement transitoire et l’évaluation systématique de la théorie de mélange dans les TSE. Le mélange distributif des polymères fondus est caractérisé par la génération de l’aire des interfaces, un paramètre difficile à mesurer expérimentalement. Alors on fait appel à des simulations numériques de type CFD / The development of new materials with improved properties seems to rely nowadays more on blending and compounding than on the synthesis of chemically new polymers. Mixing may have a great effect on the morphology and structure of multi-component polymer materials. Twin-screw extruders (TSE) are widely used as mixers/reactors for blending, compounding, and reactive processing. This work aimed at developing a new instrument to measure in real time the residence time distribution (RTD) which characterizes the axial mixing and transport abilities of different screw elements based on the analysis of the transient flow pattern and systematic evaluation of mixing theory in TSE. Distributive mixing of polymer melts is characterized by the generation of interfacial area, which is experimentally much more difficult to measure. This 3D numerical simulation based on CFD is adopted
224

Etudes théoriques et expérimentales de la processabilité du polyéthylène à ultra-haute masse molaire / Theoretical and experimental studies of the processability of ultra-high molecular weight polyethylene

Gai, Jing-Gang 16 July 2009 (has links)
Aujourd’hui le développement de nouveaux matériaux polymères ayant de bonnes propriétés repose de plus en plus sur des procédés de mélange ou de compoundage de polymères au lieu de recourir à la synthèse de nouvelles molécules. L’action du mélange peut fortement influer sur la morphologie des matériaux polymères multi-constituants. Les extrudeuses bi-vis (TSE) sont souvent utilisées comme mélangeurs/réacteurs pour des procédés de mélange, de compoundage et d’extrusion réactive. Cependant, l’étude sur la qualité du mélange dans les TSE demeure un grand défi en raison de la complexité géométrique et du caractère transitoire de l’écoulement. Cette thèse a pour objet de développer un nouvel instrument en line pour mesurer en temps réel la distribution des temps de séjour (DTS) qui caractérise la performance du mélange axial et la capacité de convoyage de différents types d’éléments de vis basées sur l’analyse de l’écoulement transitoire et l’évaluation systématique de la théorie de mélange dans les TSE. Le mélange distributif des polymères fondus est caractérisé par la génération de l’aire des interfaces, un paramètre difficile à mesurer expérimentalement. Alors on fait appel à des simulations numériques de type CFD / The development of new materials with improved properties seems to rely nowadays more on blending and compounding than on the synthesis of chemically new polymers. Mixing may have a great effect on the morphology and structure of multi-component polymer materials. Twin-screw extruders (TSE) are widely used as mixers/reactors for blending, compounding, and reactive processing. This work aimed at developing a new instrument to measure in real time the residence time distribution (RTD) which characterizes the axial mixing and transport abilities of different screw elements based on the analysis of the transient flow pattern and systematic evaluation of mixing theory in TSE. Distributive mixing of polymer melts is characterized by the generation of interfacial area, which is experimentally much more difficult to measure. This 3D numerical simulation based on CFD is adopted
225

Avaliação da resistência à tração, em diferentes períodos de cicatrização, de mini-parafusos utilizados como ancoragem temporária em ortodontia: estudo em cães da raça Beagle / Pull-out strength of unloaded orthodontic mini-screws at different healing periods. In vivo study in Beagle dogs

Ferrazzo, Vilmar Antonio 24 October 2008 (has links)
Com o objetivo de avaliar a influência do processo de cicatrização óssea sobre o desempenho biomecânico de mini-parafusos utilizados como ancoragem em ortodontia, foram inseridos 60 mini-parafusos (1,6 x 6mm) auto-rosqueantes (Tomas® Dentaurum / Germany) na maxila e na mandíbula de 5 cães adultos da Raça Beagle. Os pré-molares (P1, P2, P3, P4) superiores e inferiores foram extraídos três meses antes da inserção vertical dos mini-parafusos. Os cães foram sacrificados nos dias 0, 2, 7, 15 e 30 após a instalação dos mini-parafusos. Os maxilares foram dissecados e os corpos de provas contendo os mini-parafusos foram preparados para avaliação da resistência à tração na Máquina de Ensaios Universal EMIC® 2000, utilizando uma garra desenvolvida especificamente para este estudo. Os valores e gráficos correspondentes ao desempenho mecânico foram imediatamente gerados e registrados pelo programa de aquisição Tesc 3.01®. As possíveis diferenças entre os períodos de cicatrização foram avaliadas pela análise de variância (ANOVA) e pelo teste de comparações múltiplas de Bonferroni. Os resultados demonstraram um índice de sucesso de 100% dos mini-parafusos inseridos. Após a dissecação dos segmentos ósseos, verificou-se que em alguns casos a superfície da rosca ficou parcialmente exposta, razão pela qual o cálculo da resistência à tração (média na maxila de: 141,76 ± 92,82 Ncm a 237,02 ± 78,34 Ncm e média na mandíbula de: 156,86 ± 75,55 Ncm a 328,76 ± 82,17 Ncm) foi feito em relação à área real de inserção (maxila: 24,01 ± 6,09mm2 e mandíbula: 22,88 ± 5,31mm2), observando-se um valor médio por mm2 significativamente maior na mandíbula (11,60 ± 5,22 Ncm) quando comparado à maxila (8,22 ± 5,04 Ncm). A relação entre a intensidade da força de tração (Ncm), superfície inserida (mm2) e períodos de cicatrização não apresentaram diferenças significantes (p= 0,126). Com base nestes resultados podemos concluir que os mini-parafusos avaliados demonstraram excelente desempenho biomecânico nos diferentes períodos de cicatrização analisados, apresentando maior resistência à tração no osso mandibular. / With the purpose of evaluating the influence of bone healing process on the biomechanical performance of mini-screws used as anchorage in orthodontics, 60 self-tapping (Tomas® - Dentaurum / Germany) mini-screws were inserted (1.6 x 6 mm) in the maxilla and in the mandible of 5 adult Beagle dogs. Upper and lower premolars (P1, P2, P3, P4) were extracted three months before the vertical insertion of mini-screws. The dogs were sacrified on days 0, 2, 7, 15 and 30 after the insertion of mini-screws. The jaws were dissected and the bone blocks, containing the miniscrews, were prepared to the axial pull-out strength in the Universal Testing Machine EMIC ® 2000, using a device developed specifically for this study. The values and graphics for the mechanical performance were immediately generated and recorded by the acquisition program. The clinical success rate of mini-screws was 100%. The possible differences between the healing periods were analyzed by Bonferroni´s multiple test comparisons and variance analysis (ANOVA). After the dissection of the bone segments, it was found that in some cases, the mini-screw thread was not fully inserted into the bone, reason why the pull-out strength (average of the maxilla: 141.76 ± 92.82 Ncm to 237.02 ± 78.34 Ncm and average in the mandible of 156.86 ± 75.55 Ncm to 328.76 ± 82.17 Ncm) was evaluated in relation to the real area of insertion (maxilla: 24.01 ± 6.09 mm2 and mandible: 22.88 ± 5.31 mm2). Mean value/mm2 were significantly higher in the mandible (11.60 ± 5.22 Ncm/mm2) than the maxilla (8.22 ± 5.04 Ncm/mm2). There was no statistically significant difference (p = 0126) between pull-out strength (Ncm), surface inserted (mm2) and the observed healing periods. Based on these results it can be concluded that mini-screws evaluated in this study demonstrated an excellent biomechanical behavior in all different periods of healing, showing more resistance to traction in the mandibular bone.
226

Análise comparativa do grau de rotação de parafusos para sistema UCLA em estruturas fundidas em monobloco provenientes de \'abutments\' calcináveis e com cinta de Colbato-Cromo / Comparative analysis of the rotational angle degree on UCLA burnout/Cobalt-Chromium machined collar abutment screws for one-piece cast metal frameworks

Butignon, Luis Eduardo 21 May 2007 (has links)
Problemática: De ocorrência clínica bastante comum, o afrouxamento dos parafusos que compõe uma prótese sobre implante é uma complicação que traz transtornos tanto para o profissional quanto para o paciente. Proposição: O objetivo deste estudo foi comparar o grau de rotação de parafusos de titânio (grau 5), durante testes de torque, re-torque e os valores de destorque (Ncm), sobre infra-estruturas fundidas em monobloco, a partir de abutments tipo UCLA totalmente calcináveis e com cinta usinada em Co-Cr. Material e métodos: Um dispositivo leitor da quantidade de graus foi especialmente desenvolvido para este estudo, juntamente com um software . Dois implantes Revolution - SIN de 3,75 mm de diâmetro e 13 mm de comprimento e hexágono externo foram montados na base de um dispositivo e diretamente sobre eles foram obtidos os padrões para fundição dos corpos de prova. Cada corpo de prova foi formado por dois abutments tipo UCLA, totalmente calcináveis ou com cinta em Co-Cr, interligados por uma barra acrílica. Foram obtidos 10 corpos de prova para cada grupo e 40 parafusos de titânio (Grau 5) foram usados para os testes. Obteve-se então a medição do ângulo criado durante o aperto e re-aperto dos parafusos, sendo o re-aperto realizado após 10 minutos do aperto inicial, ambos sob torque de 30Ncm. Após o procedimento de re-aperto, o valor de destoque era imediatamente aferido e anotado em Ncm, possibilitando avaliar a quantidade de torque retido pelo parafuso após o procedimento, sendo esta seqüência realizada 3 vezes para cada corpo de prova. Análises em MEV foram realizadas nas bases de assentamento dos abutments antes e após a realização dos testes, assim como na superfície dos parafusos, a fim de se encontrar eventuais danos na microestrutura dos mesmos. O teste ?t? de student foi aplicado para uma avaliação entre os grupos e o teste ANOVA a um critério foi utilizado para análise intra-grupo. Resultados: Os resultados revelaram que durante os procedimentos de torque (aperto), os parafusos empregados em infra-estruturas obtidas a partir de abutments totalmente calcináveis apresentaram um maior grau de rotação (ensaio1: 61,664°; ensaio 2: 47,718°; ensaio 3: 47,374°), quando comparados aos parafusos empregados em infra-estruturas obtidas de abutments com cinta usinada em Co-Cr (ensaio 1: 49,038°; ensaio 2: 41,636°; ensaio 3: 43,273°), sendo a diferença entre os grupos estatisticamente significante em todos os ensaios realizados; P<0,05. Além disso, em ambos os grupos, a maior rotação dos parafusos ocorreu no primeiro aperto dos mesmos tanto durante o procedimento de torque quanto no procedimento de re-torque. Durante o re-torque, o ângulo formado na cabeça dos parafusos também foi sempre maior para o grupo Acrílico Calcinável (ensaio 1: 14,591°; ensaio 2: 12,987°; ensaio 3: 13,095°), comparado ao grupo Co-Cr (ensaio 1: 11,481°; ensaio 2: 10,117°; ensaio 3: 12,213°), sendo que diferença estatisticamente significante foi encontrada entre os ensaio 1 e 2; P<0,05. Os valores médios de destorque (quantidade de torque retido durante o aperto dos parafusos) também foram sempre maiores para o grupo Acrílico Calcinável (ensaio 1: 27,325Ncm; ensaio 2: 27,050Ncm; ensaio 3: 26,975Ncm), quando comparado ao grupo Co-Cr (ensaio 1: 26,250Ncm; ensaio 2: 26,975Ncm; ensaio 3: 26,400Ncm), porém sem diferença estatisticamente significante. As Imagens obtidas das análises em MEV demonstraram que as superfícies das bases de assentamentos do abutments obtidos a partir de abutments totalmente calcináveis apresentaram grandes irregularidades superficiais, comparadas às obtidas a partir de bases usinadas em Co-Cr, as quais apresentaram um padrão mais liso e uniforme. Quanto à análise dos parafusos, foi encontrado que as maiores deformações dos mesmos ocorrem na base de assentamento de sua cabeça no interior do abutments assim como na região da sua primeira rosca (apical). Conclusões: Tanto para o momento de torque quanto para o momento de re-torque, infra-estruturas do grupo Acrílico Calcinável permitiram maior rotação dos parafusos dos abutments, quando comparados com o grupo Co-Cr. Na análise dos valores de destorque, estatisticamente os grupos foram considerados semelhantes. Imagens em MEV, antes da realização dos testes de torque, re-torque e destorque revelaram que a base de assentamento do grupo Acrílico Calcinável apresentou aspecto mais irregular da fundição quando comparado ao grupo Co-Cr. Em ambos os grupos, partículas de titânio foram encontradas incrustadas nestas bases de assentamento após a realização desses testes, segundo dados do EDS. As imagem em MEV revelaram ainda que os parafusos se deformam principalmente na base de sua cabeça que se assenta no interior dos abutments, assim como na região da sua primeira rosca(apical). / Problem: The abutment screw loosening is a common drawback which concerns both patients and practitioners. Purpose: The aim of this study is to compare the rotational angle degree of Grade V titanium screws during torque, retorque and detorque steps (Ncm) on one-piece cast metal frameworks obtained from UCLA burnout/Co-Cr machined collar abutments. Material and methods: Two external hexagonal implants with 3.75mm in diameter and 13mm in length (Revolution, SIN) were secured to a metallic base and the wax patterns directly fabricated over them. The UCLA burnout/ Co-Cr machined collar abutments were screwed to the implants and joined together with an acrylic resin bar. Ten samples for each abutment type were fabricated. Forty Grade V titanium screws were used in the test. The rotation angle degree was measured with the aid of an specially constructed device and a computer software, during torque and retorque procedures, being the retorque made 10 minutes after the initial torque, both under 30Ncm. After the retorque procedures, the detorque values were measured. The overall sequence (torque, retorque, and detorque) was made three times for each sample. SEM analysis at the implant-abutment interfaces were made before and after the tests, as well as on the screw surfaces to detect possible microdamaging. The Student?s t test was used for between group analyses and the one-way ANOVA test for within group analyses. Results: The rotational angle degree was higher for screws used in the UCLA burnout (test 1: 61,664°; test 2: 47,718°; test 3: 47,374°) than in the Co-Cr machined collar abutments (test 1: 49,038°; test 2: 41,636°; test 3: 43,273°) (P<.05). The highest rotational degree values were observed on the first screwing during torque and retorque procedures. During retorque, the angle formed on the screw head was higher for the UCLA burnout (test 1: 14,591°; test 2: 12,987°; test 3: 13,095°) than the Co-Cr machined collar abutments (test 1: 11,481°; test 2: 10,117°; test 3: 12,213°), being these differences statistically significant between the first and second screwing (P<.05). The mean detorque values were higher in the UCLA burnout (test 1: 27,325Ncm; test 2: 27,050Ncm; test 3: 26,975Ncm) than in the Co-Cr machined collar screw abutments (test 1: 26,250Ncm; test 2: 26,975Ncm; test 3: 26,400Ncm), but not statistically significant. The SEM images demonstrated that the seating surface of the UCLA burnout abutments presented greater irregularities than the Co-Cr machined collar surfaces, which present a more smooth and flat pattern. Greater deformations were found at the seating abutment screw undersurfaces and in the first apical thread as well. Conclusions: The rotational degree was higher in the torque and retorque procedures for UCLA burnout than in the Co-Cr machined collar screw abutments. The detorque values were similar in both groups. The SEM images before torque, retorque and detorque procedures revealed more surface irregularities in the UCLA burnout abutments. In both groups, titanium debris were found in the seating abutment platforms after the tests by EDS images. The SEM images revealed that the abutment screws suffer deformation in the abutment head undersurface as well as in their first apical threads.
227

Avaliação do destorque de dois tipos de parafusos fixadores do munhão e da resistência à tração de coroas cimentadas sobre munhões com diferentes características superficiais

Toledo, Fabiane Lopes 02 September 2011 (has links)
Problemas freqüentes na prótese sobre implante são o afrouxamento do parafuso que une o munhão ao implante e a soltura da prótese cimentada. Assim, foi estudada a manutenção da força de torque, promovida por 2 diferentes parafusos fixadores de munhão, e a resistência à remoção por tração de coroas de NiCr, cimentadas ou re-cimentadas com fosfato de zinco sobre munhões com diferentes características. Numa primeira fase, foram utilizados 20 conjuntos implante/munhão/parafuso (NEODENT), constituídos de liga de Ti, nos quais existiam 10 parafusos comuns e 10 revestidos com carbono (Neotorque). A força de torque de 32 N era aplicada com um torquímetro analógico de precisão (TOHNICHI) e, para a aplicação cíclica de carga de compressão axial, foi utilizada uma máquina eletro-mecânica de fadiga, com carga de 200 N e freqüência de 2 hertz, durante 500.000 ciclos. Na segunda fase, foram usados 30 conjuntos (implante/munhão/parafuso e respectivas coroas), onde existiam apenas parafusos comuns, porém com munhões de diferentes tamanhos e aspectos superficiais: o munhão universal (MU), o personalizado original (MPO) e o personalizado irradiado (MPI). As coroas destes 2 últimos grupos já haviam sido cimentadas e tracionadas, num trabalho anterior. Todas as coroas foram agora cimentadas com fosfato de zinco e submetidas (7 dias depois) a ensaios de tração, em uma máquina universal de ensaios regulada na velocidade de 0,5 mm/min. Nas condições deste trabalho, foi possível concluir que ambos os parafusos analisados (comum e Neotorque) apresentaram comportamento semelhante, na manutenção da força de torque promovida, e que a resistência à remoção por tração de coroas, cimentadas pela primeira vez, com o munhão universal (MU), foi a menor de todas (227,83 N.cm); para os caso das recimentações, com o munhão personalizado de textura original, esta resistência apresentou valor intermediário (448,37 N.cm), tendo sido a maior de todas (1.570,76 N.cm) aquela apresentada pelo munhão personalizado que sofreu irradiação por LASER. / Frequent problems in implant prosthodontics are loosening the screw that joins the abutment to implant and the releasing of the cemented prosthesis. Thus, it was studied both the torque force mantenaince promoted by two different screws as the resistance to removal by traction of NiCr crowns, cemented or re-cemented with zinc phosphate over abutments with different characteristics. In a first phase, it were used 20 Ti alloy-made sets (composed by Neodent implant / abutment / screw), in which there were 10 slotted screws carbon-coated (Neotorque). The torque force of 32 N was applied with an analogical torque wrench (TOHNICHI) and the cyclic axial compression load with a fatigue electro-mechanical machine, with a load of 200 N and frequency of 2 Hz, over 500,000 cycles. In the second phase, it was used 30 other sets (composed by implant / abutment / screw and their crowns) where there were only common screws, but with sleeves of different size and superficial aspects: the universal abutment (MU), that personalizable with original texture (MPO) and the personalizable with a LASER treatment (MPI). Crowns of these two latter groups had already been cemented and pulled in a previous work. All crowns were here cemented with zinc phosphate and submitted (7 days later) to tensile tests in an universal testing machine set at a speed of 0.5 mm / min. In the conditions of the present work, it was concluded that both analyzed screws (common and Neotorque) behaved similarly, maintaining the torque force promoted, and that resistance to removal by traction of crowns cemented by first time with the universal abutment (MU) was the lowest of all (227.83 N.cm); for recementations, personal abutment with original texture had intermediate values resistance (448.37 N.cm), being the largest of all (1570.76 N.cm) that presented by the abutment modified by LASER irradiation.
228

Avaliação mecânica da estabilidade de parafusos protéticos em diferentes sistemas de retenção pilar/implante / Mechanical evaluation of the prosthetic screw stability from different implant/abutment retention systems

Bernardes, Sérgio Rocha 10 October 2008 (has links)
Foi analisada a variação da pré-carga de parafusos durante os cinco primeiros minutos depois de cada uma de cinco seqüências aperto e desaperto de parafusos de implantes dentários com diferentes sistemas de retenção pilar/implante. Extensômetros foram colados no terço cervical de implantes com interface de hexágono externo, hexágono interno e cone Morse. Um procedimento controlado de aperto e desaperto dos parafusos permitiu o arquivo dos valores de torque reverso, em relação ao aperto, e o campo de tensões gerado sobre o terço cervical dos implantes resultante da pré-carga do parafuso para cada uma das seqüências. Foram estudadas 30 amostras de implantes/pilares, dividas em oito grupos: implantes de hexágono externo com intermediário Munhão Universal e parafusos de titânio (Neodent, Curitiba, Brasil) apertados a 32 N.cm (EH.Ti.32); hexágono externo, Munhão Universal, parafuso de titânio recoberto por DLC, 32 N.cm (EH.dlc.32); hexágono interno, Munhão Universal, parafuso de titânio, 20 N.cm (IH.Ti.20); cone Morse, Munhão Universal peça única, 20 N.cm (MT.OP.20); cone Morse, Munhão Universal peça única, 32 N.cm (MT.OP.32); Cone Morse, Munhão Universal parafuso passante, 10 N.cm (MT.TS.10); no sétimo grupo foram usados as mesmas amostras do grupo MT.TS.10 a 10 N.cm, porém o desaperto foi realizado pelo intermediário (MT.TS.10.A); para o último grupo foram usados as mesmas amostras do grupo MT.TS.10 e MT.TS.10.A, porém o aperto dos parafusos foi de 15 N.cm e o desaperto também se deu pelo o intermediário (MT.TS.15.A). Os valores médios e desvio padrão (dp) de pré-carga encontrados para todas as seqüências de cada grupo foram de: EH.Ti.32 (27,75; dp 7,70); EH.dlc.32 (40,17; dp 10,16); IH.Ti.20 (219,61; dp 75,47); MT.OP.20 (129,19; dp 116,71); MT.OP.32 (137,97; dp 47,53); MT.TS.10 (39,55; dp 13,96); MT.TS.10.A (126,72; dp 44,05); MT.TS.15.A (194,41; 68,48). Entre os diferentes sistemas de retenção pilar/implante estudados, pode-se concluir que: existem relações únicas entre o valor de torque aplicado no parafuso e a pré-carga gerada sobre o terço cervical do implante, essas são diretamente influenciados pelo desenho da interface pilar/implante, tipo de parafuso de retenção e valor de torque aplicado; não foi observada perda de pré-carga dos parafusos de pilares, nem perda de resistência à torção no sentido anti-rotacional dos parafusos depois de esperados 5 minutos em 5 seqüências de aperto/desaperto. / The preload screw variation for the first five minutes after each one of five torque/untorque sequences from different implant/abutment retention systems was evaluated. Strain gauges were attached over the cervical third of external hex, internal hex and Morse taper implants. A controlled torque/untorque procedure allowed the record from the preload and untorque values of the samples in each one of the sequences. Thirty implant/abutment samples, divided in eight groups were studied: external hex implants with Universal post and titanium screws (Neodent, Curitiba, Brazil) screwed to 32 N.cm (EH.Ti.32); external hex, Universal post, DLC covered screw, 32 N.cm (EH.dlc.32); internal hex, Universal post, titanium screw, 20 N.cm (IH.Ti.20); Morse taper, single piece Universal post, 20 N.cm (MT.OP.20); Morse taper, single piece Universal post, 32 N.cm (MT.OP.32); Morse taper, Universal post trespassing screw, 10 N.cm (MT.TS.10); the same samples from the MT.TS.10 group were used for the seventh group, screwed to 10 N.cm, but the untorque was performed by the abutment (MT.TS.10.A); the same samples used with the MT.TS.10 and the MT.TS.10.A were used for the last group, but the screws were tightened to 15 N.cm and the untorque remained by the abutment (MT.TS.15.A). The mean and the stardad deviation (DP) found for the preloss in all the five sequences were of: EH.Ti.32 (27.75; SD 7.70); EH.dlc.32 (40.17; SD 10.16); IH.Ti.20 (219.61; SD 75.47); MT.OP.20 (129.19; SD 116.71); MT.OP.32 (137.97; SD 47.53); MT.TS.10 (39.55; SD 13.96); MT.TS.10.A (126.72; SD 44.05); MT.TS.15.A (194.41; SD 68.48). For the retention systems studied, it could be concluded that: there are single relations between screw untorque and preload over the implant cervical third, these are directely influenced by the implant/abutment interface design, screw type and torque value; there were not found post screw preload loss, neither torque resistance at the anti-rotational direction from the screws after the first five minutes in five torque/untorque sequences.
229

"Estudo comparativo do afrouxamento de diferentes parafusos de fixação de abutment em implantes de hexágono externo e interno, após o ensaio de ciclagem mecânica" / Comparative study of screw loosening for different abutment screw in external and internal hexagonal implant system after cyclic loading

Nakamura, Lilian Hitomi 28 September 2005 (has links)
A proposta deste estudo foi avaliar o torque de afrouxamento de três tipos de parafusos de fixação de abutment. Foram formados seis grupos: grupos HE-TiS e HE-TiNS (implante e abutment de hexágono externo, parafuso de fixação de titânio, submetidos e não-submetidos ao ensaio), grupos HE-AuS e HE-Au NS (implante e abutment de hexágono externo, parafuso de fixação de ouro, submetidos e não-submetidos ao ensaio) e grupos HI-TiS e HI-TiNS (implante e abutment de hexágono interno, parafuso de fixação de titânio, submetidos e não-submetidos ao ensaio). Para a realização da ciclagem mecânica, foi desenvolvida uma máquina de ensaio cuja carga máxima aplicada foi de 120 N em sentido axial, com deslizamento de 0,3mm sobre a superfície oclusal da coroa e força de atrito de 28 N a uma freqüência de 60 ciclos por minuto , durante 500.000 ciclos. O torque de apertamento inicial dos parafusos de fixação foi de 32 Ncm e o de afrouxamento mensurado a cada 100.000 ciclos nos grupos submetidos ao ensaio de ciclagem mecânica e a cada 24 horas após o torque de apertamento nos grupos não-submetidos ao ensaio. Dentro das condições experimentais deste estudo, os resultados obtidos sugerem que: os valores de destorque dos parafusos de fixação foram menores em todos os grupos submetidos ao ensaio; o destorque foi estatisticamente menor para os parafusos de titânio quando comparados os grupos HE-TiS (15,56±1,38 Ncm – 48%) / HE-AuS (18,15±1,85 Ncm – 56%) e os grupos HE-TiNS (23,76±1,59 Ncm – 74%) / HE-AuNS (27,06±1,23 Ncm – 84,5%); o destorque dos parafusos de titânio também foi estatisticamente menor quando utilizados nos grupos HE-TiS (15,56±1,38 Ncm – 48%), comparados aos grupos HI-TiS (18,56±1,14 Ncm – 58%). / The purpose of this study was to evaluate the abutment screw loosening when either submitted or not to cyclic loading. Six groups were composed: HE-TiS and HE-TiNS (external hexagonal implant and abutment, titanium abutment screw, submitted and not subimitted to cyclic loading), HE-AuS and HE-Au NS (external hexagonal implant and abutment, gold abutment screw, submitted not submitted to ciclyc loading), HI-TiS and HI-TiNS (internal hexagonal implant and abutment, titanium abutment screw, submitted and not submitted to ciclyc loading). In order to perform the cyclic loading, it was developed a device wich applied the maximum load of 120 N in the axial direction, with a slip of 0,3 mm on the crown oclusal surface with friction force of 28 N. The frequency was 60 cycles per minute for a duty of 500,000 cycles. The abutment screw was tightened to 32 Ncm and the loosening torque was measured after every 100,000 cycles in the submitted groups and every 24 hours after the tightening torque in the not-submitted groups. Within the limitations of this study, the results suggest that the loosening torque values were statistically significant lower in all groups submitted to the cyclic loading; the loosening torque was statiscally lower for titanium screws when compared HE-TiS (15,56±1,38 Ncm – 48%) / HE-AuS (18,15±1,85 Ncm – 56%) groups and HE-TiNS (23,76±1,59 Ncm – 74%) / HE-AuNS (27,06±1,23 Ncm – 84,5%) groups; the loosenig torque was also lower for the titanium screws when used to in the groups HE-TiS (15,56±1,38 Ncm – 48%) compared to HI-TiS (18,56±1,14 Ncm – 58%).
230

Contribution à l’étude de l’endommagement des connexions implantaires en odontologie prothétique / Contribution to the study of the damage in dental implant connection

Corne, Pascale 19 December 2018 (has links)
Cette recherche est basée sur l’étude de deux niveaux d’endommagements de la connexion implantaire : en premier lieu, l’usure liée aux différents cycles d’insertion/désinsertion nécessaire à l’élaboration d’une prothèse sur des échantillons implantaires ; et d’autre part, les endommagements au cours du temps, réalisés à l’aide d’une étude par fretting-corrosion en salive humaine. Lors des différents cycles de serrage/desserrage, des endommagements sur l’ensemble des composants sont présents. La vis implantaire, qui concentre la majorité des complications thérapeutiques, doit être renouvelée après 20 cycles de serrage maximum. L’utilisation de vis de laboratoire permet ainsi de limiter les dégradations sur cette dernière et d’optimiser la valeur de précontrainte lors du serrage d’usage. Lorsque la prothèse est mise en service, les endommagements sont principalement liés à des usures par tribocorrosion. Ce phénomène est à l’origine d’usure synergique et engendre une modification de la microstructure en regard des surfaces frottée / This research based on the study of two levels of damage focused on the implant connection: firstly, the wear associated with the opening/closing cycle dedicated to the manufacturing process; secondly, the damage over the time, that is a fretting-corrosion study of dental implants in human saliva. During the tightening/loosening cycles, damage to all the components is present. The screws that include the majority of the complications have to be changed after 20 tightening cycles. The use of laboratory screws limits the damage and optimizes the preload value. When the prosthesis and the implant are assemblies, the damage appears thanks to fretting/corrosion (tribocorrosion) behavior. This phenomenon does involve synergistic wear and a modification of the microstructure on the fretting surfaces

Page generated in 0.0382 seconds