Influência do tempo após manipulação na citotoxicidade e genotoxicidade de diferentes cimentos endodônticos

Oliveira, Tatiana Rocha de [UNESP] 01 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-08-01Bitstream added on 2014-06-13T19:52:05Z : No. of bitstreams: 1 oliveira_tr_me_sjc.pdf: 620321 bytes, checksum: e26df581da35d3b46846dc2f7153d000 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo deste estudo foi avaliar a citotoxicidade e a genotoxidade de quatro cimentos endodônticos: AH Plus (Dentsply De Trey, Alemanha); Endo Rez (Ultradent, USA); RoekoSeal (Coltene Whaledent, Alemanha) e o Cimento experimental à base de óleo-resina de Copaiba (Brasil). A avaliação foi realizada em três diferentes tempos após manipulação: 0h, 12h e 24h. Os espécimes foram preparados, deixados por 12 e 24h em estufa (37 °C a 100% umidade a 5% de CO2) e colocados em contato com meio de cultura (82,4 mm2 superfície/ml) por 24 h. Células V79 foram expostas à diferentes diluições dos cimentos por 24 h e a viabilidade celular foi mensurada pelo teste de MTT em espectrofotômetro. Para o teste de genotoxicidade os extratos que apresentaram concentrações de citototoxicidade média foram selecionados para o teste cometa após 24 h de exposição. A viabilidade celular e o dano ao DNA foram comparados aos grupos controles e analisados pelos testes de Kruskal-Wallis e Dunn (p<0,05). No teste de citotoxicidade, todos os cimentos apresentaram diferença significativa em relação ao controle, com exceção do RoekoSeal. A viabilidade celular de acordo com cimento utliizado pode ser classificada da maior toxicidade para a menor seguindo: EndoREZ > AH Plus > Copaíba > RoekoSeal. O dano ao DNA verificado no teste cometa pode ser classificado do maior para o menor em: EndoREZ > RoekoSeal > AH Plus > Copaíba. Conclui-se que o cimento EndoREZ é citotóxico e genotóxico nos tempos e diluições estudadas / The aim of this study was to evaluate cytotoxicity and the genotoxicity of four different root canal sealers, AH Plus (Dentsply De Trey, Germany); Endo REZ (Ultradent, USA); RoekoSeal (Coltene Whaledent, Germany) and the experimental root canal sealer based on Copaiba oil-resin sealer (Brazil). The evaluation of the materials was performed after three different times of manipulation: 0h, 12h and 24h. The specimens were prepared, incubated in a humidified incubator (37°C with 5% CO2 in air for 12h and 24h) and them put in contact with the culture medium (82,4 mm2surface/ml) during 24h. V79 cells were exposed at different dilutions of the sealers during 24h and the cell’s viability was measured by the MTT test in a spectrophotometer. For the genotoxicity tests, the extracts from the concentrations with medium citotoxicity were selected for the comet assay after 24h of exposure. The cellular viability and the DNA damage were compared with the control groups and analyzed by the tests of Kruskal-Wallis and Dunn (p<0,05). The citotoxicity test showed that all root canal sealers showed a statistically significant difference when compared with the control group, with the exception of the RoekoSeal. The ranking of cell’s viability according with sealer utilized from the most to the least toxicic material was: EndoRez > AH Plus > Copaíba > RoekoSeal. The ranking of DNA damage verified at the comet assay, from the most to the least was: EndoREZ > RoekoSeal > AH Plus > Copaíba. It was conclude that, at the times and dilutions studied, the EndoREZ sealer is genotoxic and citotoxic
22

Influência dos corantes Azul de Metileno a 2% e Rodamina B a 2% na determinação da capacidade seladora apical de diferentes cimentos endodônticos

Souza, Erick Miranda [UNESP] 30 March 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-03-30Bitstream added on 2014-06-13T19:52:05Z : No. of bitstreams: 1 souza_em_me_arafo.pdf: 1650623 bytes, checksum: 97003cfd54c5042d5a5a6e21f97e5ffc (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Banca: Idomeo Bonetti Filho / Banca: Marco Antônio Húngaro Duarte / A proposta deste trabalho foi comparar os níveis de infiltração apical determinados pelos corantes azul de metileno a 2% e Rodamina B a 2% em canais radiculares obturados com cimentos endodônticos de diferentes composições químicas. Foi também determinada a capacidade seladora apical dos cimentos Endofill, Sealer 26, AH Plus, Sealapex, EndoREZ e um cimento experimental à base de polímero de mamona (Polifil) em cada solução corante. Foram utilizados 176 dentes unirradiculares extraídos de humanos que foram instrumentados com limas do Sistema K3 de conicidade 0,04mm/mm e obturados pela técnica da condensação lateral modificada utilizando-se um cone principal de conicidade 0,04mm/mm e dois cones auxiliares. As raízes foram divididas em grupos de acordo com o cimento obturador utilizado e estes novamente divididos em subgrupos de 14 dentes cada de acordo com a solução corante a ser utilizada como traçador da infiltração. Oito dentes foram utilizados como controle sendo 4 controles positivo e 4 controles negativo. As raízes foram impermeabilizadas em toda superfície radicular externa com exceção do forame apical e submetidas à infiltração nas duas soluções corantes, em um ambiente de vácuo por 24 horas. Foram mensuradas as infiltrações apicais por meio do programa ImageTool for Windows versão 3.0 e os resultados submetidos à análise estatística pelos testes ANOVA, t-Student e Newman-Kells. Verificou-se que os níveis de infiltração determinados pelas soluções corantes dependem de qual cimento é avaliado. A solução de azul de metileno a 2% determinou nos cimentos Endofill, Sealer 26 e Sealapex menores níveis de infiltração que os determinados pela Rodamina B nos mesmos cimentos, sugerindo uma incapacidade da solução de azul de metileno a 2% em revelar a totalidade da falha da obturação realizada com estes cimentos... . / The purpose of this study was to compare the levels of apical leakage determined by the 2% methylene blue and 2% Rhodamine B dyes in root canals filled with endodontic sealers of different chemical compositions. It was also determined the apical sealing ability of the sealers Endofill, Sealer 26, AH Plus, Sealapex, EndoREZ and an experimental sealer based on castor oil polymer (Polifil) in each dyeing solution. It was used 176 single root teeth extracted from humans that were instrumented with K3 system files taper .04 and filled by the modified lateral condensation technique using a main cone taper .04 and two auxiliary cones. The roots were divided in groups according to the filling sealers that were used and these ones were divided again in subgroups of 14 teeth each one according to the dyeing solution used as infiltration tracer. Eight teeth were used as control group, four positive controls and 4 negative controls. The roots were impermeabilized on all external root surface, excepting for the apical foramen, and subjected to the infiltration into the two dye solutions in a vacuum environment for 24 hours. The apical leakage were measured by means of the software ImageTool® for Windows version 3.0 and the results were subjected to statistical analysis by the tests ANOVA, t-Student and Newman-Kells. It was noticed that the levels of leakage determined by the dye solutions depend on which sealer is evaluated. The 2%methylene blue solution in the sealers Endofill, Sealer 26 and Sealapex presented lower levels of leakage compared to the ones determined by 2% Rhodamine B in the same sealers, suggesting that 2% methylene blue dye is unable to determine the total extension of the leakage in those sealers. The other sealers did not present significant differences in the apical leakage levels determined by both dye solutions. In relation to the apical sealing... (Complete abstract, click electronic address below).
23

Comparação "in vitro" da adesão de diferentes cimentos endodônticos à dentina radicular e aos componentes sólidos da obturação /

Barbizam, João Vicente Baroni. January 2006 (has links)
Orientador: Mário Tanomaru Filho / Banca: Marco Antônio Húngaro Duarte / Banca: Manoel Damião de Souza Neto / Banca: Luis Geraldo Vaz / Banca: Idomeo Bonetti Filho / Resumo: O objetivo desse estudo é avaliar "in vitro", por meio dos testes de push-out e tração, a adesão de diferentes cimentos endodônticos à dentina e aos componentes sólidos da obturação, guta-percha e resilon. Sessenta dentes humanos uniradiculares tiveram suas coroas removidas e foram divididos em três gupos de vinte dentes. Cada grupo foi instrumentado pela técnica rotatória até uma lima tipo Profile 40.04 e alargados com uma broca de preparo de pino com 1,5 mm de diâmetro, sob irrigação com hipoclorito de sódio 2,5% (NaOCl) seguido de irrigação final com EDTA 17%; gel de clorexidina 2%(CHX) alternado com soro fisiológico e seguido por EDTA 17% ou apenas com soro fisiológico, como controle. A seguir, foram obturados com os cimentos AH 26, Endo Fill, Endo Rez e Epiphany. Após 48 horas de incubação a 37 graus Celsius e 100% de umidade, os dentes foram cortados tranversalmente em discos de 2 mm de espessura. As amostras foram submetidas à força de compressão pelo teste de push-out. Para o teste de tração, discos de guta-percha e resilon foram criados e os cimentos AH 26, Endo Fill, Endo Rez e Epiphany foram colocados em contato com o material sólido da obturação por meio de anéis metálicos contendo os cimentos em seu interor. Após incubação as amostras foram submetidas ao teste de tração. Ambos os testes foram realizados em máquina de ensaios (1mm/min) e os resultados expressos em Mpa. O teste Anova e Newman-Keuls evidenciaram que cimento Epiphany apresentou maior adesão à dentina no teste de push-out, seguido pelos cimentos Endo Rez e AH 26 que foram semelhantes entre si e, por último o cimento Endo Fill. O uso da CHX aumentou a adesão à dentina de todos os cimentos testados. No teste de tração aos componentes sólidos, o cimento AH 26 mostrou ter uma maior adesão que os demais cimentos, que foram semelhantes entre si. / Abstract: The aim of this in vitro study was to evaluate the bond strength of different root canal sealers to dentin and to the filling core material, using push-out and tensile tests. Sixty extracted single-rooted human teeth were divided into three groups and evenly instrumented with the crown-down technique up to a file #55 followed by a root canal enlargement using a 1,5 mm diameter post drill. Teeth were prepared under irrigation with 2.5% NaOCl + EDTA 17 %, 2% CHX associated to a saline solution + EDTA 17% or just saline solution, as control. All teeth were completely filled with AH 26, Endo Rez, Endo Fill and Epiphany sealers. After 48 hours of storage in 100% humidity at 37°C, all samples were sectioned transversally into 2mm thickness disks and the push-out tests were performed. For the tensile tests, gutta-percha and resilon disks were created and metallic rings with the sealers were positioned over the core material disks, in the same time/temperature conditions. Both push-out and tensile tests were performed using the universal testing machine (1 mm/min) and the maximum load at failure expressed in MPa. Two-way ANOVA and Newman-Keuls tests showed that Ephipany sealant presented the highest bond strength to dentin followed by Endo REZ and AH 26 that were similar to each other and Endo Fill with the lowest values of bonding to dentin. 2% CHX irrigation increased the bonding strength of all sealers to dentin. Tensile tests to the filling core materials showed that AH 26 presented the highest values of bonding. No statistical differences were found between the other sealers. / Doutor
24

Influência dos corantes Azul de Metileno a 2% e Rodamina B a 2% na determinação da capacidade seladora apical de diferentes cimentos endodônticos /

Souza, Erick Miranda. January 2004 (has links)
Orientador: Roberto Miranda Esberard / Banca: Idomeo Bonetti Filho / Banca: Marco Antônio Húngaro Duarte / Resumo: A proposta deste trabalho foi comparar os níveis de infiltração apical determinados pelos corantes azul de metileno a 2% e Rodamina B a 2% em canais radiculares obturados com cimentos endodônticos de diferentes composições químicas. Foi também determinada a capacidade seladora apical dos cimentos Endofill, Sealer 26, AH Plus, Sealapex, EndoREZ e um cimento experimental à base de polímero de mamona (Polifil) em cada solução corante. Foram utilizados 176 dentes unirradiculares extraídos de humanos que foram instrumentados com limas do Sistema K3 de conicidade 0,04mm/mm e obturados pela técnica da condensação lateral modificada utilizando-se um cone principal de conicidade 0,04mm/mm e dois cones auxiliares. As raízes foram divididas em grupos de acordo com o cimento obturador utilizado e estes novamente divididos em subgrupos de 14 dentes cada de acordo com a solução corante a ser utilizada como traçador da infiltração. Oito dentes foram utilizados como controle sendo 4 controles positivo e 4 controles negativo. As raízes foram impermeabilizadas em toda superfície radicular externa com exceção do forame apical e submetidas à infiltração nas duas soluções corantes, em um ambiente de vácuo por 24 horas. Foram mensuradas as infiltrações apicais por meio do programa ImageTool for Windows versão 3.0 e os resultados submetidos à análise estatística pelos testes ANOVA, t-Student e Newman-Kells. Verificou-se que os níveis de infiltração determinados pelas soluções corantes dependem de qual cimento é avaliado. A solução de azul de metileno a 2% determinou nos cimentos Endofill, Sealer 26 e Sealapex menores níveis de infiltração que os determinados pela Rodamina B nos mesmos cimentos, sugerindo uma incapacidade da solução de azul de metileno a 2% em revelar a totalidade da falha da obturação realizada com estes cimentos... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to compare the levels of apical leakage determined by the 2% methylene blue and 2% Rhodamine B dyes in root canals filled with endodontic sealers of different chemical compositions. It was also determined the apical sealing ability of the sealers Endofill, Sealer 26, AH Plus, Sealapex, EndoREZ and an experimental sealer based on castor oil polymer (Polifil) in each dyeing solution. It was used 176 single root teeth extracted from humans that were instrumented with K3 system files taper .04 and filled by the modified lateral condensation technique using a main cone taper .04 and two auxiliary cones. The roots were divided in groups according to the filling sealers that were used and these ones were divided again in subgroups of 14 teeth each one according to the dyeing solution used as infiltration tracer. Eight teeth were used as control group, four positive controls and 4 negative controls. The roots were impermeabilized on all external root surface, excepting for the apical foramen, and subjected to the infiltration into the two dye solutions in a vacuum environment for 24 hours. The apical leakage were measured by means of the software ImageTool® for Windows version 3.0 and the results were subjected to statistical analysis by the tests ANOVA, t-Student and Newman-Kells. It was noticed that the levels of leakage determined by the dye solutions depend on which sealer is evaluated. The 2%methylene blue solution in the sealers Endofill, Sealer 26 and Sealapex presented lower levels of leakage compared to the ones determined by 2% Rhodamine B in the same sealers, suggesting that 2% methylene blue dye is unable to determine the total extension of the leakage in those sealers. The other sealers did not present significant differences in the apical leakage levels determined by both dye solutions. In relation to the apical sealing... (Complete abstract, click electronic address below). / Mestre
25

Influência da agitação de 4 cimentos com ultrassom na capacidade seladora, penetrabilidade dentinária e qualidade da obturação pela técnica da condensação lateral ativa / Influence of ultrasonic agitation of 4 root canal sealers on the sealing ability and obturation quality

Bruno Martini Guimarães 06 May 2013 (has links)
Avaliou-se a adaptação da obturação às paredes do canal, a penetrabilidade dos cimentos nos túbulos dentinários, a qualidade da obturação e a capacidade seladora utilizando-se quatro cimentos obturadores a base de resina epóxi (AH Plus, AcroSeal, AdSeal e Sealer 26), quando submetidos a agitação ultrassônica no momento da inserção do cimento. Foram utilizados 84 caninos humanos recém extraídos, unirradiculados e que foram divididos em dois grupos A e B (n=40), sendo que cada grupo foi dividido em quatro subgrupos de 10 dentes cada, conforme o cimento empregado: A1 e B1 - AH Plus, A2 e B2 Acroseal, A3 e B3 Adseal e A4 e B4 Sealer 26. O preparo biomecânico foi efetuado utilizando-se de instrumentação rotatória com sistema ProTaper, determinando um batente apical com o instrumento F5 (50.05) no comprimento real de trabalho. Foi realizada, em todos os dentes, a padronização do forame até o instrumento Protaper F3. Em seguida, os cimentos foram corados com a Rodamina B. Os canais foram então obturados por meio da técnica da condensação lateral, sendo os canais do grupo A previamente preenchidos pelos cimentos obturadores e submetidos à agitação ultrassônica enquanto que os do grupo B foram considerados como controle e não foram submetidos a agitação. Os dentes então foram submetidos ao teste de infiltração de fluídos após 7 e 30 dias de realizada a obturação. Após esse período, foram realizadas três secções transversais a 2, 4 e 6 mm do ápice e as imagens das secções foram obtidas em estereomicroscópio e microscopia a laser confocal. Para análise entre grupos, no período de 7 e 30 dias em relação ao teste de infiltração apical, foi selecionado o teste não-paramétrico de Kruskall-Wallis e Dunn (p<0.05). Para as demais análises, foi utilizado o teste não-paramétrico Mann Whitney e Wilcoxon. Os resultados indicaram que a agitação ultrassônica aumentou a infiltração apical de forma significante para o cimento AH Plus no período de 7 dias. No que diz respeito à penetração de cimento na dentina, houve um aumento significante para os cimentos AHPus, Acrosela e Sealer 26 no terço médio, e para o AH Plus e Sealer no terço cervical. Com relação às fendas, a agitação ultrassônica favoreceu menor presença desta para o AH Plus na porção apical, e para todos os cimentos na região média e cervical. Concluiu-se que a agitação ultrassônica não proporcionou melhorias no selamento apical e favoreceu maior penetração de cimento na dentina e menor presença de fendas na região média e cervical. / The aim of this study was to evaluate the adaptation of the filling of the canal walls, the penetration of cements in the dentinal tubules, the quality of the filling and sealing capacity utilizing four different epóxic based sealers (AH Plus, Acroseal, AdSeal and Sealer 26), when submitted to ultrasonic agitation at the time of the obturation. Eighty four extracted uniradicular human canines were utilized, and they were divided into two experimental groups A and B (n = 40), and each group was divided into four groups of 10 teeth each, in accordance with the cement used: A1 and B1 - AH Plus, A2 and B2 - Acroseal, A3 and B3-Adseal and A4 and B4 - Sealer 26. The biomechanical preparation was performed utilizing rotary instrumentation with theProTaper system, determining an apical stop with a F5 instrument (50.05) in the real working length. The standardization of the foramen was performed on all teeth until the Protaper F3 instrument. The cements were stained with Rhodamine B. Next the canals were filled by the lateral condensation technique. The canals of group A were previously filled by the sealers and submitted to ultrasonic agitation while those in Group B were considered as the controls and were not subjected to agitation. The teeth were then submitted to testing for leakage of fluids 7 and 30 days after the obturation. After this period, three transverse cross sections were performed at 2, 4 and 6 mm from the apex and the images of the sections were obtained in a stereomicroscope and confocal laser microscopy. For the analysis between the groups, in the period of 7 and 30 days, in relation to the apical leakage test, was selected the nonparametric Kruskal-Wallis and Dunn tests (p <0.05). For the other analyzes, the nonparametric Mann Whitney and Wilcoxon tests was used. The results indicated that the ultrasonic agitation significantly increased apical leakage for the AH Plus in the period of 7 days. With regard to the penetration of the cement into the dentin, there was a significant increase for the AHPus, Acroseal and Sealer 26 cements in the middle third, and the AH Plus and Sealer 26 in the cervical third when the ultrasonic agitation was performed. Regarding the cracks, the ultrasonic agitation favored a smaller presence for the AH Plus in the apical portion, and for all cements in the middle region and cervical. It was concluded that the ultrasonic agitation did not improve the apical seal and favored greater penetration of cement into the dentin and less presence of cracks in the middle and cervical region.
26

Avaliação das propriedades físico-químicas dos cimentos obturadores dos canais radiculares à base de ionômero de vidro e silicone / Comparison of physicochemical properties of an ionomer-based and two silicon-based endodontic sealers.

Daniel Silva Herzog Flores 17 December 2009 (has links)
Este estudo avaliou, in vitro, tempo de endurecimento (TE), alteração dimensional (AD), solubilidade (Sl) e radiopacidade (Rp) dos cimentos AH Plus, GuttaFlow, RoekoSeal, Activ GP, Endofill e um cimento experimental à base de MTA. Para estes testes o cimentos Activ GP foi manipulado na relação pó/líquido de 28 mg para 50 &micro;L de líquido. Para determinar o TE, moldes (10 X 2 mm) foram preenchidos com cimento e, decorridos 150 s, os cimentos foram testados com agulha tipo Gillmore (100 g), a cada 60 s, até que não houvesse marcas na superfície. Para o teste de alteração dimensional, 5 corpos-de-prova cilíndricos (3,58 x 3,0 mm) foram obtidos. Após a mensuração de seus comprimentos por meio de parquímetro digital, foram imersos em 2,24 mL de água destilada e deionizada por 30 dias e mensurados novamente. Para o teste de Sl, foram obtidos 10 corpos-de-prova (1,5 X 7,75 mm). Após serem pesados, dois a dois, foram imersos em 7,5 mL de água destilada por 7 dias e pesados novamente, determinando-se a perda percentual da massa. Os líquidos de imersão foram submetidos à espectrometria para detecção dos íons Ca2+, K+, Ni2+, Pb2+, Zn2+, Ag+. Para a Rp, 5 placas de acrílico com 4 perfurações (5 X 1 mm) foram preenchidas com cimento e, ao lado de escada de alumínio padronizada, foram radiografadas com distância foco-objeto de 30 cm e exposição de 0,2 s. A densidade radiográfica foi determinada por meio do Digora for Windows 1.51. Os resultados mostraram que os cimentos GuttaFlow e RoekoSeal estavam de acordo com a Especificação n° 57 da ANSI/ADA para os testes de TE e Rp. Em relação a ED, somente o Guttaflow estava de acordo com esta Especificação. Em relação à Sl, somente o cimento Activ GP (11,80%) não atendeu os padrões exigidos pela ANSI/ADA. A espectrometria de absorção atômica mostrou que o cimento Activ GP apresentou liberação expressiva de ions Ca2+. A liberação de ions Zn2+ foi evidenciada no cimento Activ GPl. Concluiu-se que somente cimento Guttaflow atendeu às exigências da ANSI/ADA em relação à radiopacidade, estabilidade dimensional e solubilidade. / This study evaluated, in vitro, the setting time (ST), dimensional alteration (DA), solubility (Sl) and radiopacity (Rp) of the sealers AH Plus, GuttaFlow, RoekoSeal, Activ GP, Endofill and a MTA-based experimental sealer. For these tests, the sealer Activ GP was prepared using a powder/liquid mixing ratio of 28 mg to 50 &micro;L of liquid. In order to determine the ST, moulds (10 x 2 mm) were filled with sealer. After 150 s, the sealers were tested with a Gilmore needle (100 g) at 60-s intervals until no marks were visible on the material surface. For the DA test, 5 cylindrical specimens (3.58 x 3.0 mm) were obtained. After having their dimensions checked with a digital caliper, the specimens were stored in 2.24 mL distilled deionized water for 30 days and their dimensions were rechecked. For the Sl test, 10 specimens (1.5 x 7.75 mm) were obtained. After being weighed in pairs, the specimens were stored in 7.5 mL distilled water for 7 days and reweighed to determine the percent mass loss. The liquids in which the specimens were immersed were subjected to spectrometry for detection of ions Ca2+, K+, Na+, Ni2+, Pb2+, Zn2+and Ag+. For the Rp test, 5 acrylic plates with 4 perforations (5 x 1 mm) were filled with sealer and were radiographed near to a graduated aluminum stepwedge with 30-cm focus-object distance and 0.2-s exposure time. The radiographic density was determined using the Digora for Windows 1.51 software. The results showed that GuttaFlow and RoekoSeal were in compliance with the ANSI/ADAs specification no. 57 for the TE and Rp tests. Regarding DA, only GuttaFlow was in accordance with this specification. Regarding Sl, only Activ GP (11.80%) did not meet the ANSI/ADAs requirements. The atomic absorbance spectrometry showed that the sealer Activ GP presented significant release of Ca2+. Release of Zn2+ ions was observed for the sealer Activ GP. In conclusion, only the sealer Guttaflow met the ANSI/ADAs requirements for radiopacity, dimensional stability and solubility.
27

Role of relative humidity in concrete expansion due to alkali-silica reaction and delayed ettringite formation: relative humidity thresholds, measurement methods, and coatings to mitigate expansion

Rust, Charles Karissa 03 September 2009 (has links)
Premature concrete deterioration due to alkali-silica reaction (ASR) and delayed ettringite formation (DEF) is a significant problem all over the world. In cases where these mechanisms were not initially prevented, mitigation is critical to halt expansion and cracking. The main objectives of the research presented herein were to study the effect of ambient relative humidity (RH) on rates of concrete expansion, to determine RH thresholds below which expansion due to ASR and/or DEF may be suppressed, and to evaluate coatings intended to lower the internal RH of concrete and thus minimize future potential for damage. Results from testing showed that the RH threshold for ASR was below 82%, the RH threshold for DEF was below 92%, and the RH threshold for combined ASR and DEF could be about 83% for the materials tested. Furthermore, it was shown that some coatings are effective in reducing ASR- and DEF-related expansion by lowering the internal RH of concrete. / text
28

Avaliação in vitro da capacidade seladora e da qualidade da obturação de quatro cimentos endodônticos utilizando a técnica do cone único / In vitro evaluation of sealing-ability and obturation quality of four endodontic sealers using the single cone obturation technique

Silva, Pablo Andres Amoroso 10 May 2013 (has links)
O objetivo deste trabalho foi avaliar o selamento apical em 7 e 30 dias de, obturações de canais radiculares com a técnica de cone único utilizando 4 cimentos endodônticos, AH Plus, MTA Fillapex, cimento Portland, e cimento experimental Sealepox, por meio do sistema de infiltração de fluidos FLODEC, e a qualidade de obturação, em microscopia confocal a laser, analisando o perímetro de penetração dos cimentos nos túbulos dentinários, e a porcentagem de fendas na interface cimento/dentina, e por meio de estereomicroscopia, a porcentagem de cimento, guta-percha e espaços vazios a 2,4 e 6mm do ápice radicular, dos cimentos. Sessenta e oito dentes unirradiculados, com canais únicos tiveram seus canais instrumentados e, então, obturados com os cimentos, previamente corados com Rodamina B. As amostras foram conservadas em meio úmido a 37º de temperatura. Após 7 dias, os dentes foram adaptados para os testes de infiltração de fluidos, fazendo-se as leituras durante 12 minutos constantes, para todos os espécimes. Trinta dias depois, as leituras foram realizadas novamente com os mesmos parâmetros anteriores. Todos os espécimes foram cortados em secções de 2mm de espessura nos níveis de 2,4 e 6mm do ápice radicular. Mediante estereomicroscopia, foram calculadas as porcentagens de cimento, guta-percha e espaços vazios, e em microscopia confocal, as porcentagens de fendas e o perímetro de penetração dos cimentos no interior dos túbulos dentinários, em todas as secções. Os resultados obtidos mostraram que, todos os cimentos permitiram a infiltração de fluidos em 7 dias, sendo que, o MTA Fillapex exibiu, significativamente, menor infiltração que os cimentos AH Plus e Portland. Em 30 dias não houve diferenças estatísticas entre os cimentos. Nas avaliações em microscopia confocal, observou-se a presença de fendas na interface dentina/cimento em todas as secções avaliadas. À estereomicroscopia observaram-se espaços vazios em todas as secções, bem como, variações nas porcentagens de cimento e guta-percha. / The aim of this study was to evaluate sealing-ability at 7 and 30 days of root canal obturations using a single cone obturation technique of 4 endodontic sealers, AH Plus, Mta Fillapex, Portland Cement and a experimental sealer Sealepox, using a fluid filtration recording device (FLODEC), to evaluate the obturation quality using confocal laser microscopy analyzing interfacial adaptation of sealer/dentin interface, perimeter of sealer penetration into dentinal tubules, and using stereomicroscopy, the percentage of sealer, guta-percha and voids at 2, 4 and 6mm from de apex. Sixtyeight single rooted teeth with one canal were instrumented and then, obturated, with the sealers, in which, Rodamine B was previously added. Samples were stored in 100% humidity and at 37º temperature. After 7 days, all the specimens were submitted to microleakage tests for a 12-minute period. Mta Fillapex showed the lowest leakage percentage when compared with AH Plus and Portland cement. 30 days after the first test, microleakage evaluations were repeated, and the results showed no statistical differences. Then, all samples were cut horizontally of 2mm of thickness at 2,4,6mm from the apex. Using estereomicrocopy, percentage of sealer, guta-percha and voids were measured, and using confocal laser microscopy percentages of interfacial adaptation and perimeter of sealer penetration into dentinal tubules were calculated. According to the results it was concluded that all sealers permitted fluid filtration at 7 and 30 days, being that, at 7 days, MTA Fillapex exhibited significantly, less fluid filtration than AH Plus and Portland Cement. At 30 days, no statistically differences were found. On confocal evaluations, it was observed the presence of gaps at the sealer/dentin interface in all evaluated sections. Stereomicroscopy assessments showed voids in all sections and as well variations on sealer and guta-percha percentages.
29

Avaliação da resistência da união de cimentos obturadores resinosos à dentina radicular, por meio do teste push-out acoplado ao microtomógrafo / Evaluation of bond strength of resin-based sealers to radicular dentin by push-out test coupled to a microtomography

Brito Júnior, Manoel 05 December 2014 (has links)
O objetivo deste estudo foi avaliar a resistência de união à dentina da obturação de canais radiculares com cimentos à base de resina epóxica e de metacrilato, por meio do dispositivo material testing stage (MTS) acoplado ao microtomógrafo (&mu;CT), bem como avaliar qualitativamente a ruptura da massa obturadora por meio de imagens de &mu;CT. Além disso, foram utilizados o método de elementos finitos 3D e microscopia confocal de varredura a laser (MCVL) para verificar, respectivamente, a distribuição de tensões e presença de gaps na interface de união. Raízes de caninos superiores com 17 mm de comprimento foram submetidas ao preparo biomecânico com instrumentos rotatórios de níquel titânio, sob irrigação constante com NaOCl 1% e irrigação final com EDTA 17%. Os canais foram obturados pela técnica da condensação lateral com cones de guta percha e os cimentos: AH Plus, Epiphany SE ou RealSeal XT. As raízes foram armazenadas (100% de umidade, 37°C) por três vezes o tempo de endurecimento do cimento utilizado. Após este período, as raízes foram seccionadas para obtenção de dois slices (2 mm) de cada terço radicular. Um slices de cada terço foi submetido ao teste de push-out através de dispositivo mecânico MTS acoplado ao &mu;CT SkyScan 1174 (50kV, 80mA). Após o escaneamento inicial do slices, com resolução isotrópica de 13 &mu;m, filtro de 0.5 mm de Al e 360º de rotação, o teste mecânico foi iniciado até que ocorresse o deslocamento do material. Novo escaneamento foi realizado com os mesmos parâmetros iniciais, que determinou regiões de ruptura da massa obturadora em secções axiais. Os tipos de falhas foram avaliados por MCVL e classificadas em: adesivas, coesivas e mistas. Modelos 3D de elementos finitos foram gerados para os terços cervical, médio e apical, a partir de imagens de &mu;CT. No segundo slices de cada terço radicular, foi aferido o percentual de gaps do material obturador às paredes do canal radicular, por meio de MCVL e do programa OLS 4000. Os dados foram analisados por testes estatísticos paramétricos e não paramétricos (p<0,05). O cimento AH Plus [1,89 (1,01/2,39) MPa] apresentou maior resistência de união à dentina (p<0,001) quando comparado aos cimentos Epiphany SE [0,36 (0,29/0,44) MPa] e RealSeal XT [0,43 (0,32/0,54) MPa]. Para os cimentos AH Plus e RealSeal XT, os terços cervical e médio apresentaram maior resistência de união à dentina que o terço apical (p<0,001). As rupturas ocorreram nas margens da massa obturadora para o cimento AH Plus, enquanto os cimentos Epiphany SE e RealSeal XT tiveram este tipo de ruptura, bem como na própria massa obturadora. No cimento AH Plus, a interface de união mostrou maior concentração de tensões, que foram distribuídas principalmente na massa obturadora para os cimentos Epiphany SE e RealSeal XT. Houve predominância de falhas adesivas e mistas em todos os cimentos. Em relação ao percentual de gaps, o cimento AH Plus apresentou as menores médias (11,14% ± 4,03), com diferença estatisticamente significante (p<0,05) dos cimentos Epiphany SE (55,39% ± 13,46) e RealSeal XT (62,50% ± 6,72). O cimento à base de resina epóxica (AH Plus) apresentou a maior resistência de união à dentina e teve comportamento diferente em relação aos outros cimentos, quanto à ruptura da massa obturadora e distribuição de tensão interfacial. Além disso, o cimento AH Plus apresentou o menor percentual de gaps entre o material obturador e as paredes do canal radicular / The aim of this study was to evaluate the bond strength of epoxy resin- and methacrylate-based sealers to root dentin, using the material testing stage (MTS) coupled to a micro-computed tomography (&mu;CT) device and to qualitatively assess the root-filling mass rupture by &mu;CT images. Additional analyses were conducted using the 3D element finite method and confocal laser scanning microscopy (CLSM) to verify, respectively, the stress distribution and percentage of gaps on dentin filling material interfaces. Maxillary canine roots measuring 17 mm were subjected to biomechanical preparation with nickel-titanium rotary instruments under constant irrigation with 1% NaOCl and final irrigation with 17% EDTA. Canals were filled by the lateral condensation technique with gutta-percha cones and the following sealers: AH Plus, Epiphany SE or RealSeal XT. The roots were stored (100% humidity, 37 °C) for a period three times longer than the setting time required for each sealer and then sectioned transversally to obtain two 2-mm-thick slices from each root third. One slice of each third was subjected to the push-out test using the MTS coupled to the SkyScan 1174 &mu;CT (50 kV, 80 mA) with 13 &mu;m isotropic resolution, 0.5 mm Al filter and 360° rotation. After the initial scanning of the slice, the mechanical test was performed until material dislodgement occurred. A new scanning was performed using the same initial parameters. The axial sections obtained were used for qualitative evaluation of the root-filling mass rupture. Failure modes were assessed by CLSM and classified as adhesive, cohesive or mixed. 3D &mu;CT based finite element models were generated from cervical, middle and apical root thirds to simulate the push-out test. The second slice of each root third was used to assess the percentage of gaps between the filling material and the root canal walls, using CLSM with the aid of the OLS 4000 software. The data were analyzed by parametric and non-parametric tests (p<0.05). AH Plus presented higher bond strength [1.89 (1.01/2.39) MPa] to dentin (p<0.001) than Epiphany SE [0.36 (0.29/0.44) MPa] and RealSeal XT [0.43 (0.32/0.54) MPa]. For AH Plus and RealSeal XT sealers, the cervical and middle thirds showed higher bond strength to dentin than the apical third (p <0.001). The ruptures occurred in the margins of the root filling mass for AH Plus, while Epiphany SE and RealSeal XT had this type of rupture as well as in the root filling mass itself. AH Plus showed stress concentration on bond interface, while in Epiphany SE and RealSeal XT the stress was mainly distributed on the root-filling mass. Adhesive and mixed failures were the predominant fracture modes in all sealers. Regarding the percentage of gaps between the filling material and the root canal walls, AH Plus presented the lowest means (11.14%±4.03), differing significantly (p<0.05) from Epiphany SE (55.39%±13.46) and RealSeal XT (62.50%±6.72) sealers. The epoxy resin-based sealer (AH Plus) presented the highest bond strength to dentin, which had different behavior from other sealers regarding root-filling mass rupture and interfacial stress distribution. Moreover, AH Plus resulted in the lowest percentage of gaps between the material and the root canal walls
30

Análise da qualidade do selamento apical de canais radiculares irradiados com os lasers de Nd:YAG, diodo ou ER:YAG e obturados com os cimentos resinosos AH Plus™, EndoREZ®, Epiphany® ou Epiphany SE® / Quality analysis of the apical seal of root canals irradiated with Nd: YAG, diode or Er: YAG lasers and filled with AH Plus, EndoREZ®, Epiphany® or Epiphany SE® resin based sealers

Moura Netto, Cacio de 11 March 2009 (has links)
O objetivo deste estudo foi analisar a influência da irradiação com lasers de alta intensidade antes da obturação de canais radiculares com cimentos endodônticos resinosos no selamento apical. Raízes permanentes humanas (n=168) foram endodonticamente tratadas e, então, divididas aleatoriamente em quatro grupos experimentais (n=42), de acordo com o tratamento dentinário subsequente. Os grupos foram: GØ (controle) sem tratamento adicional; GN irradiado com o laser de Nd:YAG (1,5 W, 100 mJ, 15 Hz); GD irradiado com o laser de diodo (2,5 W em modo contínuo); GE irradiado com o laser de Er:YAG (1 W, 100 mJ, 10 Hz). Dois espécimes de cada grupo foram preparados para avaliação em microscopia eletrônica de varredura (MEV) convencional para observação morfológica da superfície dentinária apical. Os espécimes remanescentes de cada grupo foram aleatoriamente divididos em quatro subgrupos (n=10), de acordo com o cimento obturador utilizado (AH Plus, EndoREZ®, Epiphany® ou Epiphany SE®). Para a análise de infiltração, os espécimes foram imersos em solução amoniacal de nitrato de prata a 50 % (pH=9,5) por 24 horas. Os valores de infiltração apical, em mm, foram comparados pela ANOVA, seguido pelo teste de Tukey (p<0,05). Cinco secções de cada subgrupo foram aleatoriamente selecionadas e analisadas em MEV em modo ambiental para avaliar a adaptação e penetração do material obturador nas paredes dentinárias. As imagens em MEV ambiental foram classificadas em escores por três avaliadores calibrados. A concordância interexaminadores foi confirmada pelo teste Kappa e os escores foram comparados pelo teste de Kruskal-Wallis (p<0.05). No grupo controle, o cimento EndoREZ® apresentou infiltração de nitrato de prata significantemente menor que todos os outros cimentos (p<0,05), com exceção do Epiphany®. A irradiação com os lasers de Nd:YAG e de diodo diminuiu a infiltração média dos subgrupos obturados com o cimento AH Plus (p<0,05). A irradiação com o laser de Nd:YAG levou a um aumento do nível de infiltração nos subgrupos obturados com EndoREZ® e Epiphany SE®. A adaptação, bem como a penetração dos cimentos, não foram prejudicadas pela prévia irradiação com laser dos canais radiculares, independentemente do laser utilizado. / The aim of this study was to analyze the influence of intracanal high intensity laser irradiation prior to root canal filling with resin based endodontic sealers on the apical sealing. Human dental roots (n=168) were endodontically treated and then randomly divided into four experimental groups (n=42), according to the further dentin surface treatment. The groups were: control (GØ) received no further treatment; GN irradiated with Nd:YAG laser (1.5 W, 100 mJ, 15 Hz); GD irradiated with diode laser (2.5 W in continuous way) and GE irradiated with Er:YAG laser (1 W, 100 mJ, 10 Hz). Two specimens of each group were prepared for conventional scanning electron microscopy (SEM) for morphological observation of the apical dentin surface. The remaining specimens of each group were randomly divided into four subgroups (n=10), according to the sealer used for dental root filling as follows: AH Plus, EndoREZ®, Epiphany® or Epiphany SE®. For leakage analysis, the specimens were immersed into 50 % silver nitrate ammoniacal solution (pH = 9.5) for 24 hours. The values of apical leakage, in mm, were compared by ANOVA followed by Tukeys test (p<0,05). Five sections of each subgroup were randomly selected and analyzed using environmental SEM in order to evaluate the adaptation and penetration of the filling material into the dentin walls. The environmental SEM images were scored by three calibrated examiners. The inter-examiners agreement was confirmed by Kappa test and the scores were compared by Kruskal-Wallis test (p<0.05). At the control group, the EndoREZ® sealer led to significantly smaller silver nitrate leakage in comparison to the others sealers (p<0,05), except by Epiphany®. The irradiation with Nd:YAG and diode lasers reduced the mean leakage of the subgroups filled with AH Plus sealer (p<0,05). Nd:YAG laser irradiation led to a leakage level increase of the subgroups filled with EndoREZ® and Epiphany SE®. The adaptation as well as sealer penetration were not impaired by the root canal prior laser irradiation, independently of the laser used.