• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • Tagged with
  • 35
  • 21
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Uso de infiltrante sobre esmalte hígido e com lesão inicial de erosão submetido a desafio erosivo in vitro

Oliveira, Gabriela Cristina de 28 May 2013 (has links)
O presente trabalho teve como objetivo avaliar in vitro a eficácia da aplicação do infiltrante comparativamente a um selante e dois sistemas adesivos na prevenção (etapa 1 esmalte hígido) e na inibição da progressão de lesões erosivas iniciais de esmalte associado ou não ao condicionamento da superfície de esmalte previamente à aplicação dos materiais (etapa 2). Os espécimes foram preparados a partir de esmalte bovino. Na etapa 1 (prevenção), as superfícies de esmalte hígidos (H) foram aleatoriamente divididos em 5 grupos, de acordo com o material aplicado: HCn sem tratamento controle negativo, HH aplicação de selante resinoso de fossas e fissuras Helioseal Clear®, HA aplicação de sistema adesivo autocondicionante Adhese®, HT aplicação de sistema adesivo convencional Tetric N-bond®, HI aplicação de infiltrante Icon®. Na etapa 2, todos os espécimes foram inicialmente imersos em HCl 0,01M, pH2,3 por 30 s, simulando a lesão inicial de erosão, e posteriormente aleatorizados em 9 grupos (E). Nos grupos ECn, EH, EA, ET e EI, os espécimes foram tratados com os mesmos materiais respectivamente, seguindo as recomendações dos fabricantes e nos grupos EHs, EAs, ETs e EIs não houve condicionamento da superfície de esmalte. Para as duas etapas, todos dos espécimes após tratamento, foram submetidos à ciclagem erosiva, pela imersão dos espécimes 4x/dia por 5 dias em ácido clorídrico (0,01M; pH 2,3) por 2 minutos, seguida da imersão em saliva artificial por 120 min e overnight. O desgaste do esmalte e a análise de espessura dos materiais foram avaliados por perfilometria e os resultados submetidos à Kruskal-Wallis e Teste de Dunn (p<0,05). Na etapa 1, o infiltrante (HI), selante (HH) e adesivo autocondicionante (HA) protegeram o esmalte contra a erosão e foram significativamente diferentes do controle, sendo efetivos na prevenção da erosão. Na etapa 2, os grupos EH, EA, EI (selante, adesivo autocondicionante, infiltrante), ETs e Eis (adesivo convencional e infiltrante, ambos sem condicionamento ácido), foram semelhantes e não promoveram alteração no esmalte, sendo os mais eficazes na inibição da progressão da erosão. Maior desgaste do esmalte foi observado nos grupos ECn ( sem tratamento controle negativo), ET ( sistema adesivo convencional de 2 passos), EHs (selante resinoso de fossas e fissuras sem condicionamento ácido), EAs (sistema adesivo autocondicionante sem condicionamento ácido), sendo estatisticamente similares. Considerando os resultados conclui-se que a aplicação de infiltrante Icon® (com ou sem condicionamento do esmalte) e de selante de fossas e fissuras Helioseal Clear®, sobre o esmalte hígido ou com lesão inicial de erosão foram efetivos para prevenir e inibir a progressão erosiva. / This study aimed to evaluate in vitro the efficacy of the application of infiltrant, compared to sealant and two different adhesive systems on prevention (phase 1 - sound enamel) and inhibition of the progression of erosive lesions associated or no the enamel surface conditioning prior to application of the material (phase 2). The specimens were prepared from bovine enamel. In phase 1 (prevention), the sound enamel surface (H) were randomly divided into 5 groups according to the material used: HCN untreated - negative control, HH application of resin sealant - Helioseal Clear®, HA application of self-etching adhesive system - AdheSE®, HT application of phosphoric acid-etching adhesive system - Tetric Nbond ®, HI application of infiltrant - Icon®. In phase 2, all specimens were eroded by immersion in 0.01 M HCl, pH 2,3 for 30 s to simulate initial erosion lesion, and then randomized into 9 groups (E). In groups ECn, EH, EA, ET and EI, the specimens were treated with the same materials, respectively, following the manufacturers recommendations and the groups, EHs, EAs, ETs e EIs no enamel surface conditioning was performed. For both phases, all blocks were subjected to erosive cycling by immersion of the blocks in hydrochloric acid (0.01 M, pH 2.3) for 2 minutes, followed by immersion in artificial saliva for 120 minutes 4x/day for 5 days. The enamel alteration was evaluated by profilometry and the results subjected to Kruskal-Wallis and the Dunns test (p <0.05). In phase 1, the infiltrant (HI), sealant (HH) and self-etching adhesive (HA) protected the enamel against erosion and were significantly different from control. In phase 2, the groups EH, EA, EI (sealant, selfetching adhesive, infiltrant), ETs and EIs (phosphoric acid-etching adhesive and infiltrant, both without surface conditioning) were similar and showed no enamel alteration after erosion. Greater enamel wear was observed in groups ECn (untreated - negative control), ET (phosphoric acid-etching adhesive), EHs (resin sealant without surface conditioning), AEs (self-etching adhesive without surface conditioning) and these were statistically similar. Taking into consideration the results, it is concluded that the application of infiltrant (with or without prior enamel conditioning) and sealants on sound and initially eroded enamel, prevented enamel alterations when subjected to erosive challenge.
12

Selante de fóssulas e fissuras para o controle de lesões de cárie oclusal: um ensaio clínico controlado randomizado / Pit and fissure sealant to control of occlusal caries lesions: a controlled randomized clinical trial

Jaccottet, Cleusa Marfiza Guimarães 19 December 2014 (has links)
Submitted by Fabiano Malheiro (fabianomalheiro22@hotmail.com) on 2017-05-25T13:32:42Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Selante de fóssulas e fissuras para o controle de lesões de cárie oclusal um ensaio clínico controlado randomizado.pdf: 1278912 bytes, checksum: d3e4ca8a1615fb3b7faf3bfa5b9f23e6 (MD5) / Made available in DSpace on 2017-05-25T13:32:42Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Selante de fóssulas e fissuras para o controle de lesões de cárie oclusal um ensaio clínico controlado randomizado.pdf: 1278912 bytes, checksum: d3e4ca8a1615fb3b7faf3bfa5b9f23e6 (MD5) Previous issue date: 2014-12-19 / Sem bolsa / Revisões sistemáticas e metanálises, com base em ensaios clínicos controlados e randomizados (ECR), demonstram que o selante resinoso apresenta um bom desempenho quando aplicado em superfícies oclusais hígidas ou na presença de lesões não cavitadas. Estudos clínicos também demonstram que o selamento de lesões cavitadas com extensão em dentina propicia a paralisação do processo carioso, induzindo ganho mineral. Mesmo diante da importância da utilização de tratamentos minimamente invasivos, poucos ECR têm sido realizados visando estabelecer a longevidade do selante resinoso e seu desempenho clínico quando aplicado em superfícies com presença de lesões que apresentam ruptura da superfície e extensão em dentina. O presente ECR avaliou a longevidade do selante resinoso de fóssulas e fissuras em lesões com microcavidades de até 0,5 mm de diâmetro, com desmineralização na dentina em superfícies oclusais de molares permanentes em pacientes jovens de 10 a 25 anos, e comparou ao tratamento restaurador convencional com resina composta por um período de 22 meses. A avaliação dos materiais foi realizada com base nos critérios da Federação Dentária Internacional-FDI, sendo utilizadas para a avaliação dos resultados a análise bivariada e a curva de sobrevivência dos materiais (p < 0,05). Cinquenta e um pacientes, sessenta e um dentes receberam a intervenção, destes, quarenta pacientes totalizando cinquenta e um dentes foram avaliados, sendo que 25 receberam selante (49%) e 26 restaurações com resina composta (51% - grupo controle). Conforme resultados, o grupo dos selantes falhou mais que o das restaurações de resina composta. Dos 25 dentes selados, oito (32%) apresentaram fratura ou perda total ou parcial do material, enquanto que dos 26 dentes restaurados com resina composta, nenhum apresentou falha (P= 0,003). A taxa de falha anual para o selante foi de 18,9%, dos oito dentes em que constaram falhas, dois apresentaram fratura de esmalte e presença de cavidade de cárie dentária. O selante também apresentou menor probabilidade de sobrevivência em pacientes com presença de lesão ativa após o período de acompanhamento (p=0,005), com desempenho inferior ao da resina composta em relação à adaptação marginal (p=0,046). Diante dos resultados encontrados neste estudo, podemos concluir que o selante resinoso teve desempenho inferior em comparação com restaurações de resina composta para o tratamento de lesões de cárie com extensão em dentina. / Systematic reviews and meta-analysis based on controlled and randomized clinical trials (RCT) have been showed that resin sealant has a good clinical performance when applied in sound surfaces or in non-cavitated lesions. Others clinical studies have shown that sealing of caries lesions, including those that are localized in the middle third of dentin, can reduce the bacterial growth in the infected dentin leading to stop the carious process and inducing mineral gain. Few RCT have been conducted to establish the resin sealant longevity and its clinical performance when applied to caries lesions which present breaks into enamel and dentin surface. This RCT evaluated the resin sealant longevity applied in occlusal surface of permanent molar that present caries lesions with microcavities (up to 0.5mm diameter) and compared to conventional restorative treatment (composite resin) from young patients aged 10 to 25 years for a period of up to 22 months. Dental materials were evaluation according FDI criteria. Bivariate analysis and survival curves were used to evaluate the results (p <0.05). Fifty one patients and 61 teeth received the allocates intervention. From these, forty patients (51 teeth) were evaluated. Of those, 25 teeth received sealant (49%), and 26 resin composite treatment (56%-control group). The sealant group showed more failures than composite resin restorations. Eight of 25 teeth with sealant (32%) presented fracture or total or partial material loss. None tooth with composite resin restoration showed failure (P= 0.003). Sealant annual failure rate was 18.9%. Sealant also presented a lower survival probability in patients with active caries lesion at evaluation time (P = 0.005), and showed inferior performance compared to resin composite when marginal adaptation was evaluated (p = 0.046). Therefore, the resin sealant showed inferior performance when compared to composite resin restoration for caries lesion presenting microcavities with dentin extension.
13

Impacto nos resultados assistenciais e nos custos hospitalares do emprego do selante de fibrina na anastomose pancreatojejunal após ressecção duodenopancreática / Impact on health care outcomes and hospital costs of the use of fibrin sealant in pancreatojejunal anastomosis after duodenopancreatic resection

Alberto Facury Gaspar 15 May 2015 (has links)
Introdução: Os benefícios do emprego do selante de fibrina no reforço de anastomoses pancreatico-jejunais, após ressecção duodenopancreática, visando a redução da incidência de fístula pancreática pós operatória (FPPO), ainda são questionáveis. Objetivo: Avaliar a influência do emprego do selante de fibrina na anastomose pancreatico-jejunal, após duodenopancreatectomia, na incidência de fístula, bem como suas consequências clínicas e os custos hospitalares. Metodologia: Estudo retrospectivo de 62 pacientes consecutivos submetidos a duodenopancreatectomia, divididos em dois grupos: 31 pacientes utilizando o selante de fibrina (GCS) e 31 pacientes sem o emprego de selante (GSS). As variáveis estudadas foram agrupadas em epidemiológicas, clínicas, laboratoriais, com destaque para a incidência de fístula pancreática, classificada segundo a definição do International Study Group on Pancreatic Fistula, suas complicações pós operatórias catalogadas segundo a classificação de Clavien e suas repercussões na assistência e nos seus custos avaliados pelo método de absorção com rateio simples de todas as despesas, exceto a despesa com medicamentos, tratada de forma separada. Resultados: Os grupos foram homogêneos para os parâmetros epidemiológicos, clínicos, e laboratoriais e não foram registradas diferenças significativas na comparação da evolução pós operatória e dos indicadores assistenciais hospitalares. Por outro lado, os custos hospitalares foram mais elevados no GCS, em relação ao GSS (p<0,0001). Conclusão: O emprego do selante de fibrina, no reforço da anastomose pancreatico-jejunal, em pacientes submetidos a duodenopancreatectomias, nas condições estudadas, não melhorou os resultados clínicos e assistenciais e ainda aumentou os custos hospitalares. / Introduction: The benefits of fibrin sealant employment in strengthening pancreatico-jejunal anastomosis after duodenopancreatic resection, reducing the incidence of pancreatic fistula postoperative (PFPO) are still questionable. Objective: To evaluate the influence of the use of fibrin sealant in pancreatico-jejunal anastomosis after pancreaticoduodenectomy in the incidence of fistula and its clinical consequences and hospital costs. Methodology: A retrospective study of 62 consecutive patients who underwent pancreaticoduodenectomy, divided into two groups: 31 patients using fibrin sealant (GCS) and 31 patients without the sealant employment (GSS). The variables were grouped into epidemiological, clinical, laboratory, especially the incidence of pancreatic fistula classified as defined by the International Study Group on Pancreatic Fistula, their postoperative complications cataloged according to Clavien rating and its repercussions on care and its costs assessed by the absorption method with simple apportionment of all expenses except the expenditure on medicines, treated separately. Results: The groups were homogeneous for clinical, epidemiological and laboratory parameters and no significant differences were recorded in the comparison given postoperative progress and hospital assistance indicators. Moreover, hospital costs were higher in GCS, with respect to GSS (p <0.0001). Conclusion: The use of fibrin sealant in pancreatojejunal anastomosis after pancreaticoduodenectomy, in the studied conditions, did not improve the results of care and also increased hospital costs
14

Influência da aplicação de selantes de superfície na perda de massa e alteração da rugosidade superficial de um compósito após aplicação tópica de flúor fosfato acidulado e ensaio de escovação / Influence of the application of surface sealants on weight loss and change of surface roughness of a composite after topical application of acidulated phosphate fluoride and toothbrushing assay

Bianca Mataveli Vimercati 17 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo teve por objetivo avaliar a degradação de um compósito após ciclos de escovação simulada, com ou sem a aplicação de selantes de superfície e com ou sem a aplicação tópica de flúor fosfato acidulado (FFA). A avaliação foi feita através da análise alteração da massa e da rugosidade superficial. Foram confeccionados 80 corpos-de-prova (CP) com o compósito Z250 (3M) (8mm x 3mm) e divididos em 4 grupos. Todos os grupos tiveram as superfícies regularizadas com lixa dágua 1.200. O grupo A (controle) não recebeu selamento, o grupo B recebeu aplicação do selante de superfície Fortify (Bisco), o grupo C, BisCover (Bisco) e o grupo D, Fill Glaze (Vigodent). Após isso, os CP foram armazenados em água destilada por 7 dias, em temperatura ambiente e, posteriormente, pesados em balança analítica para obtenção da massa inicial e submetidos à análise da rugosidade superficial inicial, utilizando rugosímetro Surftest SJ 201 P Mitutoyo. Os grupos A, B, C e D foram subdivididos em 2 grupos cada (n:10) e um subgrupo da cada grupo inicial (A2, B2, C2 e D2) foi submetido à aplicação de FFA (4 min), antes da escovação. Os grupos A1, B1, C1 e D1 permaneceram em água destilada. Após a remoção do FFA, todos os grupos foram armazenados em saliva artificial por 1 hora, em temperatura ambiente. Posteriormente foram submetidos a 30.000 ciclos de escovação, representando 6 meses de escovação diária. Foi utilizada escova dental macia (Ultra) e uma solução de creme dental (Colgate Máxima Proteção Anticáries) e água destilada na proporção de 1:2. Ao fim do ensaio, os CP foram lavados em água corrente por 5 minutos, secos com papel absorvente, pesados novamente para obtenção da massa final e submetidos à análise da rugosidade superficial final. O desgaste de cada CP foi avaliado através da perda de massa, que foi calculada pela diferença das pesagens antes e após a escovação e a alteração da rugosidade superficial foi calculada pela diferença entre os valores das médias de rugosidade superficial inicial e final. Algumas amostras foram analisadas em microscópio de força atômica com finalidade ilustrativa. Os dados obtidos foram tratados estatisticamente. Na análise da alteração de massa, quando comparado os grupos isoladamente, somente o grupo D1(FIL) não sofreu alteração de massa significativa. As comparações entre as médias de alteração de massa dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa somente nas comparações: A1(CONT)xB1(FFY) e B1(FFY)xD1(FIL). Para os grupos que receberam FFA, não houve diferença significativa entre as médias de alteração de massa. Na análise da alteração de rugosidade superficial, quando comparado os grupos isoladamente, houve aumento significativo de rugosidade superficial nos grupos A2(FFA), B2(FFY+FFA), C1(BIS) e C2(BIS+FFA). As comparações entre as médias de alteração de rugosidade superficial dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa apenas na comparação: C1(BIS)xD1(FIL). Para os grupos que receberam FFA, as comparações A2(FFA)xD2(FIL+FFA); B2(FFY+FFA)xD2(FIL+FFA); C2(BIS+FFA)xD2(FIL+FFA) mostraram diferenças significativas. Não foi observada correlação estatisticamente significante entre a alteração de massa e rugosidade superficial entre os grupos analisados. Com base nos resultados obtidos e na análise estatística realizada, pôde-se concluir que a aplicação de FFA e a aplicação de selantes de superfície não tiveram influência na alteração de massa e na rugosidade superficial dos materiais testados. O selante de superfície Fortify não protegeu o compósito após escovação, apresentando uma maior perda de massa no grupo B1 (Fortify) em comparação com o grupo A1 (controle). Os demais selantes testados protegeram o compósito. Não existiu correlação significativa entre perda de massa e alteração da rugosidade. / The aim of this study was to assess the degradation of a composite after simulated toothbrushing cycles, with or no applying surface sealants and with or no topical application of acidulated phosphate fluoride (APF). The assessment was made by analysis of change of weight and of surface roughness. Eighty specimens were made with the Z250 composite (3M) (8 mm x 3 mm) and divided in 4 groups. All the groups have their surfaces regularized with sandpapers 1.200 under water. The group A (control) have not seal, in the group B was applied the surface sealant Fortify (Bisco), in the group C the BisCover (Bisco), and in the group D the Fill Glaze (Vigodent). Following, the specimens were stored in distilled water for 7 days at room temperature and, subsequently, they were weighted in analytical scales for obtaining initial weight and subjected to analysis of initial surface roughness using the Surftest SJ 2001 P Mitutoyo profilometer of surface roughness. The groups A, B, C and D were subdivided in 2 groups each (n = 10) and a subgroup of every initial group (A2, B2, C2, D2) was subjected to application of APF (for 4 minutes) before the toothbrushing. The groups A1, B1, C1 and D1 remained in distillated water. After the removal of the APF, all the groups were stored in artificial saliva for 1 hour at room temperature. Subsequently they were subjected to 30000 cycles toothbrushing, representing 6 months of daily toothbrushing. The soft toothbrush (Ultra) and a toothpaste (ColgateCavity Protection) and distillated water in ratio 1:2 were used. At final of assay, the specimens were washed in running water for 5 minutes, dried with absorbent paper, measured again in order to obtain the final weight, and they were subjected to analysis of final surface roughness. The wear of each specimen was assessed by weight loss, which was calculated by difference of measuring before and after toothbrushing, and the change of surface roughness was calculated by difference between the values of initial and final surface roughness. Some samples were analysed in atomic force microscope with illustrative purpose. The data were treated statistically. In the analysis of weight change, when compared to groups separately, only the group D1 (FIL) have no significant weight change. The comparisons between the means of weight change of groups with or no APF showed there are no significant differences between all the comparisons: A1 (CONT) X B1 (FFY) and B1 (FFY) x D1 (FIL). For the groups with APF, there are no significant differences between the means of weight change. In the analysis of surface roughness change, when compared to groups separately, there was a significant increase of surface roughness in groups A2 (APF), B2 (FFY + APF), C1 (BIS) and C2 (BIS + APF). The comparisons between the means of surface roughness change of the groups with and no APF revealed there no differences significant between all of comparisons. For the groups with no APF, there was significant difference only in comparison C1 (BIS) x D1 (FIL). For the groups with APF, the comparisons A2 (APF) x D2 (FIL + APF), B2 (FFY + APF) x D2 (FIL + APF), C2 (BIS + APF) x D2 (FIL + APF) showed significant differences. It wasnt noted correlation significant statistically between weight change and surface roughness between the groups analyzed. With basis on findings obtained and in the statistical analysis accomplished, it could to conclude that the application of APF and the use of surface sealants have not influence on the weight change and surface roughness of composite tested. The surface sealant Fortfy have not protected the composite after toothbrushing, showing the higher weight loss in the group B1 (Fortfy) when compared to group A1 (control). The remainder sealants tested has protected the composite. There wasnt significant correlation between weight loss and roughness change.
15

Influência da aplicação de selantes de superfície na perda de massa e alteração da rugosidade superficial de um compósito após aplicação tópica de flúor fosfato acidulado e ensaio de escovação / Influence of the application of surface sealants on weight loss and change of surface roughness of a composite after topical application of acidulated phosphate fluoride and toothbrushing assay

Bianca Mataveli Vimercati 17 December 2007 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo teve por objetivo avaliar a degradação de um compósito após ciclos de escovação simulada, com ou sem a aplicação de selantes de superfície e com ou sem a aplicação tópica de flúor fosfato acidulado (FFA). A avaliação foi feita através da análise alteração da massa e da rugosidade superficial. Foram confeccionados 80 corpos-de-prova (CP) com o compósito Z250 (3M) (8mm x 3mm) e divididos em 4 grupos. Todos os grupos tiveram as superfícies regularizadas com lixa dágua 1.200. O grupo A (controle) não recebeu selamento, o grupo B recebeu aplicação do selante de superfície Fortify (Bisco), o grupo C, BisCover (Bisco) e o grupo D, Fill Glaze (Vigodent). Após isso, os CP foram armazenados em água destilada por 7 dias, em temperatura ambiente e, posteriormente, pesados em balança analítica para obtenção da massa inicial e submetidos à análise da rugosidade superficial inicial, utilizando rugosímetro Surftest SJ 201 P Mitutoyo. Os grupos A, B, C e D foram subdivididos em 2 grupos cada (n:10) e um subgrupo da cada grupo inicial (A2, B2, C2 e D2) foi submetido à aplicação de FFA (4 min), antes da escovação. Os grupos A1, B1, C1 e D1 permaneceram em água destilada. Após a remoção do FFA, todos os grupos foram armazenados em saliva artificial por 1 hora, em temperatura ambiente. Posteriormente foram submetidos a 30.000 ciclos de escovação, representando 6 meses de escovação diária. Foi utilizada escova dental macia (Ultra) e uma solução de creme dental (Colgate Máxima Proteção Anticáries) e água destilada na proporção de 1:2. Ao fim do ensaio, os CP foram lavados em água corrente por 5 minutos, secos com papel absorvente, pesados novamente para obtenção da massa final e submetidos à análise da rugosidade superficial final. O desgaste de cada CP foi avaliado através da perda de massa, que foi calculada pela diferença das pesagens antes e após a escovação e a alteração da rugosidade superficial foi calculada pela diferença entre os valores das médias de rugosidade superficial inicial e final. Algumas amostras foram analisadas em microscópio de força atômica com finalidade ilustrativa. Os dados obtidos foram tratados estatisticamente. Na análise da alteração de massa, quando comparado os grupos isoladamente, somente o grupo D1(FIL) não sofreu alteração de massa significativa. As comparações entre as médias de alteração de massa dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa somente nas comparações: A1(CONT)xB1(FFY) e B1(FFY)xD1(FIL). Para os grupos que receberam FFA, não houve diferença significativa entre as médias de alteração de massa. Na análise da alteração de rugosidade superficial, quando comparado os grupos isoladamente, houve aumento significativo de rugosidade superficial nos grupos A2(FFA), B2(FFY+FFA), C1(BIS) e C2(BIS+FFA). As comparações entre as médias de alteração de rugosidade superficial dos grupos que receberam e que não receberam FFA revelaram não existir diferenças significativas entre todas as comparações. Com relação aos grupos que não receberam FFA, houve diferença significativa apenas na comparação: C1(BIS)xD1(FIL). Para os grupos que receberam FFA, as comparações A2(FFA)xD2(FIL+FFA); B2(FFY+FFA)xD2(FIL+FFA); C2(BIS+FFA)xD2(FIL+FFA) mostraram diferenças significativas. Não foi observada correlação estatisticamente significante entre a alteração de massa e rugosidade superficial entre os grupos analisados. Com base nos resultados obtidos e na análise estatística realizada, pôde-se concluir que a aplicação de FFA e a aplicação de selantes de superfície não tiveram influência na alteração de massa e na rugosidade superficial dos materiais testados. O selante de superfície Fortify não protegeu o compósito após escovação, apresentando uma maior perda de massa no grupo B1 (Fortify) em comparação com o grupo A1 (controle). Os demais selantes testados protegeram o compósito. Não existiu correlação significativa entre perda de massa e alteração da rugosidade. / The aim of this study was to assess the degradation of a composite after simulated toothbrushing cycles, with or no applying surface sealants and with or no topical application of acidulated phosphate fluoride (APF). The assessment was made by analysis of change of weight and of surface roughness. Eighty specimens were made with the Z250 composite (3M) (8 mm x 3 mm) and divided in 4 groups. All the groups have their surfaces regularized with sandpapers 1.200 under water. The group A (control) have not seal, in the group B was applied the surface sealant Fortify (Bisco), in the group C the BisCover (Bisco), and in the group D the Fill Glaze (Vigodent). Following, the specimens were stored in distilled water for 7 days at room temperature and, subsequently, they were weighted in analytical scales for obtaining initial weight and subjected to analysis of initial surface roughness using the Surftest SJ 2001 P Mitutoyo profilometer of surface roughness. The groups A, B, C and D were subdivided in 2 groups each (n = 10) and a subgroup of every initial group (A2, B2, C2, D2) was subjected to application of APF (for 4 minutes) before the toothbrushing. The groups A1, B1, C1 and D1 remained in distillated water. After the removal of the APF, all the groups were stored in artificial saliva for 1 hour at room temperature. Subsequently they were subjected to 30000 cycles toothbrushing, representing 6 months of daily toothbrushing. The soft toothbrush (Ultra) and a toothpaste (ColgateCavity Protection) and distillated water in ratio 1:2 were used. At final of assay, the specimens were washed in running water for 5 minutes, dried with absorbent paper, measured again in order to obtain the final weight, and they were subjected to analysis of final surface roughness. The wear of each specimen was assessed by weight loss, which was calculated by difference of measuring before and after toothbrushing, and the change of surface roughness was calculated by difference between the values of initial and final surface roughness. Some samples were analysed in atomic force microscope with illustrative purpose. The data were treated statistically. In the analysis of weight change, when compared to groups separately, only the group D1 (FIL) have no significant weight change. The comparisons between the means of weight change of groups with or no APF showed there are no significant differences between all the comparisons: A1 (CONT) X B1 (FFY) and B1 (FFY) x D1 (FIL). For the groups with APF, there are no significant differences between the means of weight change. In the analysis of surface roughness change, when compared to groups separately, there was a significant increase of surface roughness in groups A2 (APF), B2 (FFY + APF), C1 (BIS) and C2 (BIS + APF). The comparisons between the means of surface roughness change of the groups with and no APF revealed there no differences significant between all of comparisons. For the groups with no APF, there was significant difference only in comparison C1 (BIS) x D1 (FIL). For the groups with APF, the comparisons A2 (APF) x D2 (FIL + APF), B2 (FFY + APF) x D2 (FIL + APF), C2 (BIS + APF) x D2 (FIL + APF) showed significant differences. It wasnt noted correlation significant statistically between weight change and surface roughness between the groups analyzed. With basis on findings obtained and in the statistical analysis accomplished, it could to conclude that the application of APF and the use of surface sealants have not influence on the weight change and surface roughness of composite tested. The surface sealant Fortfy have not protected the composite after toothbrushing, showing the higher weight loss in the group B1 (Fortfy) when compared to group A1 (control). The remainder sealants tested has protected the composite. There wasnt significant correlation between weight loss and roughness change.
16

"Resistência de união, ao ensaio de microtração, de selante e sistemas adesivos aplicados em superfícies oclusais de molares decíduos" / Micro-tensile bond strength of sealant and adhesive systems applied on occlusal surfaces of primary molars.

Ana Cláudia Durante Ramires-Romito 31 March 2005 (has links)
O objetivo deste estudo foi avaliar a resistência de união, ao ensaio de microtração, de selante (Clinpro, 3M) e sistemas adesivos (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) aplicados em superfícies oclusais de molares decíduos (n=32). Os produtos avaliados foram testados após serem aplicados de acordo com as recomendações dos fabricantes e após contaminação da superfície oclusal com saliva. Após armazenagem em água por 24h a 37ºC, cada dente foi secionado no plano mésio-distal e perpendicularmente à interface de união para obtenção de corpos-de-prova em forma de palito com seção transversal retangular e área aproximada de 0,6 mm 2 . Cada corpo-de-prova foi submetido ao teste de tração em máquina de ensaio universal a uma velocidade de 0,5 mm/min e os fragmentos armazenados para análise posterior do padrão de fratura em microscopia eletrônica de varredura. As fraturas foram classificadas em: adesiva mista, tipo 1 (fratura tanto de material restaurador, isto é associação de adesivo/resina composta, como do esmalte e o substrato predominante foi esmalte); adesiva mista, tipo 2 (fratura tanto de material restaurador como do esmalte e o substrato predominante foi o material restaurador); adesiva mista, tipo 3 (fratura tanto de material restaurador como do esmalte e houve distribuição homogênea de ambos); mista tipo 4 (fratura apenas de material restaurador, isto é, adesivo associado à resina composta) e; coesiva tipo 5 (fratura coesiva exclusivamente de um do substratos sendo esmalte ou resina composta). A análise estatística dos dados obtidos, relativos à resistência de união, usou como unidade experimental o dente. Os palitos perdidos em cada grupo foram incluídos no cálculo de resistência de cada dente. A contaminação salivar não influe nciou a perda de palitos. Não houve associação entre o padrão de fratura e os valores de resistência de união. As fraturas foram predominantemente mistas, não foi observada fratura coesiva exclusivamente de esmalte ou resina composta. Para os sistemas adesivos testados, nenhuma diferença significante foi observada entre os grupos com contaminação salivar ou não. OptiBond FL (34,5 ± 2,2 MPa) e Clinpro (45,1 ± 3,2 MPa) apresentaram valores de resistência de união similares e significativamente maiores do que o OptiBond Solo Plus (19,1 ± 2,3 MPa) e OptiBond Solo SE (9,8 ± 2,3 MPa) que foram equivalentes entre eles (p > 0,05). / The aim of this study was to evaluate the micro-tensile bond strength (mTBS) of a conventional sealant (Clinpro, 3M) and adhesive systems (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) on occlusal surface of primary molars (n=32). Sealant and adhesives were tested under manufacturers’ specifications and after contamination of the bonding site with saliva. After storage in distilled water at 37 º C for 24 h, the specimens were longitudinally sectioned perpendicular to the adhesive interface. Stick shape samples with cross-sectional areas of about 0.6 mm 2 were obtained and subjected to a tensile force in a universal testing machine at a crosshead speed of 0.5 mm/min. The bond failure modes were evaluated at scanning electron microscope and classified as following: mixed, type 1 (with cohesive failure of the neighboring substrates, wherein enamel was predominant); mixed, type 2 (with cohesive failure of the neighboring substrates, wherein adhesive/resin composite was predominant); mixed, type 3 (with cohesive failure of the neighboring substrates, wherein enamel and adhesive/resin composite was equally distributed); mixed, type 4 (with cohesive failure of the neighboring substrates, where there was only adhesive and resin composite, with none enamel fracture); cohesive, type 5 (failure exclusive within enamel or resin composite). The mean value of bond strength was calculated for each of the four teeth used per group, meaning that the experimental unit was the tooth. These were averaged to express the mean bond strength for every material at each group. The specimens lost due to pre-testing failure were included in the calculus of the mTBS of each tooth. Moisture did not influence sticks loss. There was not any association between failure mode and values of mTBS. The majority of fractures were mixed, none cohesive failure of enamel or composite resin was observed. For the tested adhesive systems no significant difference was observed between the groups under either saliva contamination or not. OptiBond FL (34.5 ± 2.2 MPa) and Clinpro (45.1 ± 3.2 MPa) showed similar values of mTBS and significantly higher than OptiBond Solo Plus (19.1 ± 2.3 MPa) and OptiBond Solo SE (9.8 ± 2.3 MPa) that were equivalent to each other (p>0.05).
17

Uso de infiltrante sobre esmalte hígido e com lesão inicial de erosão submetido a desafio erosivo in vitro

Gabriela Cristina de Oliveira 28 May 2013 (has links)
O presente trabalho teve como objetivo avaliar in vitro a eficácia da aplicação do infiltrante comparativamente a um selante e dois sistemas adesivos na prevenção (etapa 1 esmalte hígido) e na inibição da progressão de lesões erosivas iniciais de esmalte associado ou não ao condicionamento da superfície de esmalte previamente à aplicação dos materiais (etapa 2). Os espécimes foram preparados a partir de esmalte bovino. Na etapa 1 (prevenção), as superfícies de esmalte hígidos (H) foram aleatoriamente divididos em 5 grupos, de acordo com o material aplicado: HCn sem tratamento controle negativo, HH aplicação de selante resinoso de fossas e fissuras Helioseal Clear®, HA aplicação de sistema adesivo autocondicionante Adhese®, HT aplicação de sistema adesivo convencional Tetric N-bond®, HI aplicação de infiltrante Icon®. Na etapa 2, todos os espécimes foram inicialmente imersos em HCl 0,01M, pH2,3 por 30 s, simulando a lesão inicial de erosão, e posteriormente aleatorizados em 9 grupos (E). Nos grupos ECn, EH, EA, ET e EI, os espécimes foram tratados com os mesmos materiais respectivamente, seguindo as recomendações dos fabricantes e nos grupos EHs, EAs, ETs e EIs não houve condicionamento da superfície de esmalte. Para as duas etapas, todos dos espécimes após tratamento, foram submetidos à ciclagem erosiva, pela imersão dos espécimes 4x/dia por 5 dias em ácido clorídrico (0,01M; pH 2,3) por 2 minutos, seguida da imersão em saliva artificial por 120 min e overnight. O desgaste do esmalte e a análise de espessura dos materiais foram avaliados por perfilometria e os resultados submetidos à Kruskal-Wallis e Teste de Dunn (p<0,05). Na etapa 1, o infiltrante (HI), selante (HH) e adesivo autocondicionante (HA) protegeram o esmalte contra a erosão e foram significativamente diferentes do controle, sendo efetivos na prevenção da erosão. Na etapa 2, os grupos EH, EA, EI (selante, adesivo autocondicionante, infiltrante), ETs e Eis (adesivo convencional e infiltrante, ambos sem condicionamento ácido), foram semelhantes e não promoveram alteração no esmalte, sendo os mais eficazes na inibição da progressão da erosão. Maior desgaste do esmalte foi observado nos grupos ECn ( sem tratamento controle negativo), ET ( sistema adesivo convencional de 2 passos), EHs (selante resinoso de fossas e fissuras sem condicionamento ácido), EAs (sistema adesivo autocondicionante sem condicionamento ácido), sendo estatisticamente similares. Considerando os resultados conclui-se que a aplicação de infiltrante Icon® (com ou sem condicionamento do esmalte) e de selante de fossas e fissuras Helioseal Clear®, sobre o esmalte hígido ou com lesão inicial de erosão foram efetivos para prevenir e inibir a progressão erosiva. / This study aimed to evaluate in vitro the efficacy of the application of infiltrant, compared to sealant and two different adhesive systems on prevention (phase 1 - sound enamel) and inhibition of the progression of erosive lesions associated or no the enamel surface conditioning prior to application of the material (phase 2). The specimens were prepared from bovine enamel. In phase 1 (prevention), the sound enamel surface (H) were randomly divided into 5 groups according to the material used: HCN untreated - negative control, HH application of resin sealant - Helioseal Clear®, HA application of self-etching adhesive system - AdheSE®, HT application of phosphoric acid-etching adhesive system - Tetric Nbond ®, HI application of infiltrant - Icon®. In phase 2, all specimens were eroded by immersion in 0.01 M HCl, pH 2,3 for 30 s to simulate initial erosion lesion, and then randomized into 9 groups (E). In groups ECn, EH, EA, ET and EI, the specimens were treated with the same materials, respectively, following the manufacturers recommendations and the groups, EHs, EAs, ETs e EIs no enamel surface conditioning was performed. For both phases, all blocks were subjected to erosive cycling by immersion of the blocks in hydrochloric acid (0.01 M, pH 2.3) for 2 minutes, followed by immersion in artificial saliva for 120 minutes 4x/day for 5 days. The enamel alteration was evaluated by profilometry and the results subjected to Kruskal-Wallis and the Dunns test (p <0.05). In phase 1, the infiltrant (HI), sealant (HH) and self-etching adhesive (HA) protected the enamel against erosion and were significantly different from control. In phase 2, the groups EH, EA, EI (sealant, selfetching adhesive, infiltrant), ETs and EIs (phosphoric acid-etching adhesive and infiltrant, both without surface conditioning) were similar and showed no enamel alteration after erosion. Greater enamel wear was observed in groups ECn (untreated - negative control), ET (phosphoric acid-etching adhesive), EHs (resin sealant without surface conditioning), AEs (self-etching adhesive without surface conditioning) and these were statistically similar. Taking into consideration the results, it is concluded that the application of infiltrant (with or without prior enamel conditioning) and sealants on sound and initially eroded enamel, prevented enamel alterations when subjected to erosive challenge.
18

Utilização do selante de fibrina combinado com células tronco mesenquimais no reparo de nervos periféricos através da técnica de tubulização = Use of fibrin sealant combined with mesenchymal stem cells in the repair of peripheral nerves through tubulization technique / Use of fibrin sealant combined with mesenchymal stem cells in the repair of peripheral nerves through tubulization technique

Cartarozzi, Luciana Politti, 1987- 08 December 2013 (has links)
Orientador: Alexandre Leite Rodrigues de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-23T08:37:52Z (GMT). No. of bitstreams: 1 Cartarozzi_LucianaPolitti_M.pdf: 5081962 bytes, checksum: 794c493e497a269465a5b035175dfbcb (MD5) Previous issue date: 2013 / Resumo: A regeneração nervosa periférica é um processo complexo dependente do rearranjo e ativação das células de Schwann. O estímulo das células de Schwann pode ser alcançado através do enxerto de células tronco exógenas. Com o intuito de entender a importância do enxerto de células tronco mesenquimais (MSC) no processo regenerativo periférico, utilizamos o modelo de tubulização do nervo isquiático. As próteses tubulares foram preparadas a partir de membranas de poli-caprolactona (PCL) e preenchidas com selante de fibrina (FG), utilizado, neste caso, como substrato para as MSC. A técnica de tubulização foi feita em ratas fêmeas Lewis adultas, divididas em 4 grupos (n = 5 por grupo): normal, PCL (tubo vazio); FG (tubo preenchido com selante de fibrina) e FG+MSC (tubo preenchido com selante de fibrina e enxertado com MSC). Sessenta dias após lesão, os nervos regenerados foram processados para imunoistoquímica e microscopia de luz. A presença de MSC GFP-positivas foi detectada nos nervos dos animais que receberam enxerto de MSC, indicando que a sobrevivência, a longo prazo, das células tronco no tecido. A regeneração axonal, analisada por imunoistoquímica, revelou expressão de elementos básicos do nervo periférico, ou seja, componentes dos axônios e da lâmina basal tiveram a expressão equivalente em todos os grupos experimentais. A organização axonal foi observada através da marcação anti-neurofilamento. A presença das células de Schwann foi analisada através da marcação anti-S100 e o anticorpo anti-colágeno IV foi utilizado para detecção da lâmina basal. A imunomarcação anti-p75NTR, o receptor de baixa afinidade para neurotrofinas, foi utilizada para investigar a reatividade das células de Schwann. A marcação basal deste, em nervos não lesionados, foi aumentada pelo processo regenerativo, sendo estatisticamente maior no grupo FG+MSC (77% em relação ao nervo contralateral; p<0.001). Além disso, houve colocalização de MSC GFP-positivas e imunomarcação anti-BDNF, evidenciando uma possível via de atuação das células sobre o comportamento das células de Schwann. A partir da análise das secções semi-finas dos nervos pudemos avaliar que a área dos nervos regenerados no interior das próteses tubulares foi estatisticamente igual nos diferentes grupos experimentais. Quando quantificamos o número de axônios mielinizados por uma área fixa, o grupo FG+MSC apresentou maior densidade de axônios em relação ao grupo controle (25%, p<0,05). Da mesma maneira, quando analisamos os parâmetros morfométricos nos diferentes grupos experimentais, o grupo FG+MSC apresentou uma tendência a apresentar axônios de maior calibre e bainha de mielina mais espessa, em relação aos demais grupos, sendo que, a EBM, no intervalo de 1,46 a 2,25?m, foi significantemente maior em relação aos grupos PCL e FG (p<0,05). Como consequência, os animais do grupo FG+MSC mostraram recuperação motora significativamente maior na sétima e oitava semana de análise do índice funcional do nervo fibular. Os achados deste estudo mostram que as MSC enxertadas conjuntamente com selante de fibrina influenciam positivamente o processo regenerativo, modulando a reatividade das células de Schwann / Abstract: Peripheral nerve regeneration is a complex process that is dependent on the rearrangement and activation of Schwann Cells (SC). Such stimulation of SCs may be achieved by the use of exogenous stem cells. In order to better understand the importance of mesenchymal stem cell (MSC) grafting in the peripheral regeneration process we have used the model of sciatic nerve tubulization. Tubular prostheses were prepared from polycaprolactone (PCL) membranes and filled with fibrin sealant (FS), which was used as a substrate for the MSC. The technique of tubulization was applied in adult Lewis female rats that were divided into four groups (n = 5 per group): normal, PCL (empty tube), FS (tube filled with fibrin sealant) and FS + MSC (tube filled with fibrin sealant and grafted with MSC). Sixty days after injury, the regenerated nerves were processed for imunohistochemistry and observed under fluorescence microscopy. The presence of GFP positive stem cells was detected in the nerves of the animals that received MSC grafts, indicating the long term survival of such cells. The axonal regeneration process was studied by immunohistochemistry and revealed the presence of the basic elements of the peripheral nerve, namely axons and basal lamina components that were equivalent in all experimental groups. The axonal organization was observed with anti-neurofilament immunostaining. The presence of SCs was analyzed with anti-S100 immunostaining and anti-type IV collagen was used to detect the basal lamina. Anti-p75NTR, the low affinity receptor for neurotrophins, was used to investigate the reactivity of the SCs. A basal positive labeling in uninjured nerves was detected, which was upregulated by the regenerative process, being statistically higher in FS + MSC group (77% relative to uninjured nerve; p<0.001). Moreover there was colocalization between GFP-positive MSC and anti-BNDF immunolabeling, showing a possible pathway that these cells induce the reactivity of SCs. From sciatic nerve semi-thin sections we were able to evaluate that the areas of regenerated nerves were statistically the same in the different experimental groups. When we quantified the number of myelinated axons in 50.000?m2, the FG+MSC group showed higher density of axons when compared with PCL group (25%, p<0,05). In the same way, the analysis of morphometric parameters showed that the FG+MSC group have a tendency to present higher caliber axons and ticker myelin sheath when compared with other groups, being that the myelin sheath thickness, in the interval between 1,46 to 2,25?m, was significantly higher in FG+MSC group when compared to PCL and FG (p<0,05). As the functional result of the findings above, the FG+MSC animals showed higher motor function recovery, analyzed by FFI, at seventh and eighth weeks after lesion. The findings herein show that MSC associated with the FS scaffold improve the regeneration process by positively modulating the reactivity of SCs / Mestrado / Biologia Celular / Mestra em Biologia Celular e Estrutural
19

Reparabilidadede um cimento ionomérico aderido ao esmalte com sistemas adesivos autocondicionantes

Guimarães, Murilo de Sousa [UNESP] 16 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-16Bitstream added on 2014-06-13T20:24:35Z : No. of bitstreams: 1 guimaraes_ms_dr_arafo.pdf: 1443329 bytes, checksum: 2d3d8b079af9426aadd16dd726576433 (MD5) / O objetivo deste trabalho, dividido em três estudos, foi investigar (1) a reparabilidade de um cimento de ionômero de vidro modificado por resina, (2) o efeito cariostático e (3) a retenção de selantes ionoméricos aderidos ao esmalte não desgastado com sistemas adesivos autocondicionantes simplificados. Materiais e Métodos: Para o estudo 1 foram confeccionados 60 espécimes de cada material, Vitremer (VT) e resina Z250 (RC). Após envelhecimento químico e térmico, eles foram divididos em 3 grupos de acordo com o tratamento mecânico da superfície: ponta diamantada em alta rotação, ponta em ultra-som e sem desgaste. Cada espécime foi reparado com o mesmo material utilizado inicialmente. Aplicou-se na superfície do VT o Vitremer Primer (VP), e para a resina, utilizou-se ácido fosfórico seguido de adesivo Single Bond. Os espécimes foram isolados deixando exposta a interface de união. Após novo envelhecimento, os mesmos foram impregnados por nitrato de prata, seccionados e avaliados quanto à infiltração e formação de fendas. Os dados foram analisados pelos testes de Kruskal-Wallis e Mann-Whitney (α=0,05). No segundo estudo 64 incisivos bovinos foram distribuídos em 4 grupos segundo o tratamento da superfície de esmalte: VP, Prompt L-Pop (Pr), Xeno III (Xe) ou sem tratamento. Um cilindro de VT foi construído em metade dos dentes, enquanto que a RC foi utilizada na outra metade. Os corpos de prova foram 19 submetidos a desafio cariogênico e seccionados, para realização de testes de dureza em três regiões: externa, união e interna, até a profundidade de 300 μm. Os dados transformados em porcentagem de perda mineral foram analisados pelo teste de ANOVA complementado pelo teste de Tukey ao nível de significância de 5%. No terceiro estudo, 20 pares de molares permanentes hígidos foram selecionados de crianças entre 6 e 10 anos. Em um dos dentes foi aplicado... / The purpose of this work, divided into three studies, was to investigate (1) the reparability of a resin-modified glass-ionomer cement, as well as (2) the cariostatic effect and (3) retention of glass-ionomer sealants bonded to enamel with one-step self-etching adhesive systems. Materials and Methods: For the first study, 60 specimens were prepared with Vitremer (VT) and Z250 resin. After chemical and thermal aging, the specimens were divided into 3 groups according to the mechanical treatment of the surface: diamond bur, ultrasound coupled bur or no treatment. Each specimen was repaired with the original restorative material. For VT repairs, Vitremer Primer (VP) was first applied while for composite resin the surface was phosphoric acid etched followed by the application of Single Bond. The specimens were coated with acid resistant varnish except for 1 mm around de interface. After additional aging, the specimens were impregnated by silver nitrate and sectioned medialy for the evaluation of silver infiltration and gap formation in SEM. Data were submitted to Kruskal-Wallis and Mann-Whitney tests (α=0.05). In the second study, 64 bovine teeth were randomly assigned to 4 groups according to the enamel surface treatment: VP, Prompt L-Pop (Pr), Xeno III (Xe) or no treatment. A cylinder of VT was built up in half of the teeth while a composite resin was used in the other half. The teeth were then submitted to a cariogenic challenge after which they 23 were medialy cut. Transversal hardeness evaluation was performed in three regions, external, interface and internal, up to the depth of 300μm. Hardness numbers were converted to percentage of mineral loss and the data were submitted to ANOVA and Tukey tests at the level of significance of 5%. For the third study, 20 pairs of sound permanent molars were selected from children between 6 and 10 years of age. One tooth of the pair received... (Complete abstract click electronic access below)
20

Influência da remoção do excesso de materiais adesivos sobre o esmalte erodido, na resistência a desafio erosivo in vitro / Influence of removing excess of adhesive materials applied to eroded enamel on the resistance to erosive challenge

Tereza, Guida Paola Genovez 20 May 2015 (has links)
O uso de materiais resinosos sobre o tecido dentário é uma alternativa para a prevenção da progressão da erosão, contudo existem poucas informações sobre o efeito da infiltração resinosa na lesão de erosão. O objetivo deste estudo foi avaliar o efeito dos materiais resinosos sobre (sem remoção de excesso) e supostamente dentro (com remoção de excesso) do esmalte previamente erodido, submetido a desafio erosivo subsequente. Os blocos de esmalte bovino foram imersos em HCl 0,01 M, pH 2,3 durante 30 segundos para a formação de lesão inicial de erosão. Em seguida, os blocos foram divididos aleatoriamente e tratados de acordo com 8 grupos (n=12): Cc e Cs- controle sem tratamento, Hc e Hs- selante de fossas e fissuras (Helioseal Clear®), Ac e As- adesivo autocondicionante (Adhese®), Ic e Is- infiltrante (Icon®); sendo c- com remoção de excesso e s- sem remoção de excesso do material. Os materiais foram aplicados de acordo com as recomendações dos fabricantes. Nos grupos com remoção de excesso, após a aplicação dos materiais houve a remoção de seu excesso da superfície de esmalte com um cotonete, anteriormente a fotopolimerização. Após o tratamento, todos os espécimes foram submetidos à ciclagem erosiva, por meio da imersão em ácido clorídrico (0,01M; pH 2,3) por 2 minutos, seguida da imersão em saliva artificial por 120 minutos, 4 vezes ao dia, durante 5 dias. A espessura de material e o desgaste dentário foram analisados por meio da perfilometria e os resultados submetidos ao teste ANOVA a dois critérios e teste de Tukey (p<0,05). Na análise do desgaste dentário após o desafio erosivo, os grupos sem remoção de excesso (Hs, As, Is) se comportaram de forma semelhante (p>0,05), constatando-se a presença de material sobre o esmalte prevenindo a perda da estrutura dentária. Os grupos nos quais o excesso de material sobre o esmalte foi removido (Hc, Ac, Ic) resultaram em perda de esmalte após a aplicação. Além disso, esses grupos (Hc, Ac, Ic) não foram capazes de proteger o esmalte contra a erosão, uma vez que após o desafio erosivo o desgaste do esmalte destes grupos foi semelhante ao grupo controle. Com base nos resultados do presente estudo, conclui-se que os materiais resinosos são capazes de proteger o esmalte contra a erosão dentária somente quando estão presentes sobre a superfície dentária, formando uma barreira mecânica. / The use of resin-based materials over the dental tissue is an alternative for erosion progression prevention, however there is little information regarding the effect of resin infiltration into erosive lesion. The aim of this study was to evaluate the effect of resin-based materials over (without excess removal) and into (with excess removal) previously eroded enamel, subjected to erosive challenge. Bovine enamel blocks were immersed in HCl 0.01 M, pH 2.3 for 30 seconds for the formation of softened erosion lesion. Then the blocks were random divided and treated according to 8 groups (n=12): Cc and Cs- control without treatment, Hc and Hs- fissure resin sealant (Helioseal Clear®), Ac and As- self-etch adhesive (Adhese®), Ic and Isinfiltrant (Icon®); being c- with excess removal and s- without excess removal of the material. The materials were applied according to manufacture instructions. The groups with excess received the same materials, however before light curing the excess of material over enamel was gently removed with a cotton roll. After treatment, the blocks were immersed in HCl for 2 min, followed by immersion in artificial saliva for 120 min, 4 times per day, during 5 days (erosive cycling). Enamel wear and material thickness were analyzed using profilometry and the results submitted to two-way ANOVA and Tukeys test (p<0.05). Groups Hs, As, Is, resulted in the formation of a layer of material over enamel, being effective in inhibiting erosion progression. Groups in which the material over enamel was removed (Hc, Ac, Ic), resulted in enamel loss after application. In addition, they (Hc, Ac, Ic) were not able to protect enamel, since after the erosive challenge enamel wear of these groups was similar to control. Based on the results of this study, resin-based materials are able to protect enamel against erosion only when they are present over enamel, forming a mechanical barrier.

Page generated in 0.1052 seconds