Spelling suggestions: "subject:"sensibilidade dda dentina"" "subject:"sensibilidade daa dentina""
31 |
Avaliação da sensibilidade pos-operatoria de restaurações classe I de composito odontologico utilizando diferentes agentes de uniãoCasselli, Denise Sa Maia 02 April 2005 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:56:33Z (GMT). No. of bitstreams: 1
Casselli_DeniseSaMaia_D.pdf: 2775830 bytes, checksum: 43dd6d3dde0928950dc7944d0226d0be (MD5)
Previous issue date: 2005 / Resumo: Este estudo avaliou a sensibilidade pós-operatória de restaurações Classe I de compósito restauradas com sistema de união de condicionamento total ou autocondicionante. Cento e quatro restaurações defeituosas de amálgama foram substituídas em 52 pacientes. Cada paciente substituiu duas restaurações. Após preparo cavitário confeccionado, as restaurações foram confeccionadas, sob isolamento absoluto utilizando-se Single Bond ou Clearfil SE Bond e um compósito odontológico (Filtek Z250). A sensibilidade foi avaliada antes da substituição (baseline), após 7 dias e 6 meses da troca, utilizando-se estímulo frio e escala analógica de dor. Se ocorresse sensibilidade após 7 dias, os pacientes retornavam após 14 e 30 dias. Os escores foram analisados através de testes não paramétricos: Friedman e Wilcoxon. Nenhuma diferença estatística significativa foi encontrada em relação à sensibilidade pós-operatória no baseline, 7 dias e 6 meses. Também não houve diferença entre os adesivos em qualquer tempo. Nenhuma sensibilidade espontânea foi relatada. Os principais motivos de substituição de restaurações de amálgama, neste estudo, foram fratura da restauração e degradação marginal. Os sistemas de união utilizados nesse estudo não mostraram diferenças em relação à sensibilidade pós-operatória e não mostraram sensibilidade espontânea após 6 meses, quando utilizados de acordo com as instruções do fabricante / Abstract: This study evaluated the post-operative sensitivity of posterior Class I composite resin restorations restored with a self-etching primer or a total-etch bonding system. One hundred and four restorations were replaced by one clinician in 52 patients. Each patient received two restorations. After cavity preparations, the restorations were completed under rubber dam isolation and restored using a Clearfil SE Bond or Single Bond and a resin-based restorative material (Filtek Z250). The sensitivity was evaluated at O (baseline) and 7 days and 6 months using cold stimuli, and recorded using a visual-analogue scale. If sensitivity was experienced on day 7, patients were also contacted on days 14 and 30 to assess the degree of sensitivity. The se ores were analyzed as non-parametric data by means of the Friedman and Wilcoxon tests. No statistieally signifieant differences were found in sensitivity between the two adhesives systems at day O, 7 and 6 months. No spontaneous pos-operative sensitivity was reported. The major reasons for failure of amalgam restorations were fraetures restoration and marginal deficiencies. The adhesive systems used in this study showed no differenees in post-operative sensitivity, and did not show spontaneous sensitivity after 6 months if they were used accordance with manufacturer' s instructions / Doutorado / Dentística / Doutor em Clínica Odontológica
|
32 |
Ação de agentes dessensibilizantes aplicados previamente ao tratamento clareador de consultório = The effects of desensitizing agents previously applied during in-office bleaching / The effects of desensitizing agents previously applied during in-office bleachingBarbosa, Isabel Ferreira, 1988- 27 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T08:06:16Z (GMT). No. of bitstreams: 1
Barbosa_IsabelFerreira_M.pdf: 17100621 bytes, checksum: 989f3c819b4db9c4a6cb6fec6d487a59 (MD5)
Previous issue date: 2015 / Resumo: O objetivo neste estudo, duplo cego de "boca-dividida", foi avaliar, clinicamente, o efeito de dois agentes dessensibilizantes utilizados previamente à aplicação de um gel clareador, a base de peróxido de hidrogênio a 35%, com relação a sensibilidade dental, e se os mesmos interferem na efetividade do clareamento. Para isso foram consideradas duas hipóteses: os géis dessensilizantes iriam reduzir a sensibilidade decorrente do clareamento; os géis dessensibilizantes não iriam influenciar a eficácia do clareamento. Foram utilizados dois agentes dessensibilizantes com diferentes mecanismos de ação, o Flúor Neutro 2% (Flugel, DFL) (FN) que atua através do bloqueio dos canalículos dentinários enquanto o Nitrato de Potássio 5% com Fluoreto de Sódio 2% (Desensibilize KF 2%, FGM) (NP) que atua na transmissão nervosa e no bloqueio. Foram selecionados 30 pacientes, os quais receberam os quatro tratamentos, dois dessensibilizantes e dois placebos, divididos, aleatoriamente, por quadrante. O gel dessensibilizante NP e seu respectivo placebo foram aplicados durante 10 minutos em uma arcada enquanto o gel de FN e seu respectivo placebo foram aplicados por 4 minutos na outra arcada, com o cuidado para que a substância em gel permanecesse nos dentes de cada quadrante. Os dessensibilizantes foram utilizados no inicio de cada sessão, previamente à aplicação do peróxido de hidrogênio 35%. Para o clareamento foram realizadas 3 sessões clinicas, com intervalo de 7 dias entre as mesmas, havendo 3 aplicações do gel clareador por 15 minutos, totalizando 45min por sessão. Os pacientes utilizaram escala analógica de dor de 0-4 para relatarem a sensibilidade, sendo 0 = nenhuma dor, 1 = correspondente a uma dor leve, 2 = moderada, 3 = considerável e 4 = dor intensa. Antes do início de cada sessão, a cor foi registrada de forma objetiva com a utilização de espectrofotômetro (Easyshade, Vident), com o auxilio de uma matriz de silicone para que a medida da cor fosse feita sempre na mesma posição. A variação de cor (?E) foi submetida a ANOVA casual e teste de Tukey (p<0,05). A sensibilidade dental foi avaliada através de ANOVA em esquema fatorial (4x6), sendo que os fatores estudados foram dessensibilizantes e tempo. Dois pacientes desistiram após a primeira sessão de clareamento devido a grande intensidade de dor, e não foram considerados para análise estatística. A alteração de cor após a terceira semana de clareamento apresentou diferença significativa em relação a cor obtida na primeira semana. A intensidade de dor foi estatisticamente significante para os fatores tempo e dessensibilizante, mas não para a interação entre os mesmos. O NP apresentou redução da intensidade de dor quando comparado ao seu placebo, porém a aplicação de FN não diferiu do seu placebo. Com relação ao tempo, a intensidade de dor foi menor durante o clareamento do que nas semanas entre os tratamentos. Pôde-se concluir que a utilização do dessensibilizante a base de nitrato de potássio a 5% e fluoreto de sódio a 2%, aplicado previamente ao clareamento, reduziu a intensidade da sensibilidade dolorosa durante a aplicação do gel clareador, sem alterar a efetividade do clareamento / Abstract: This double blind split-mouth study clinically evaluated the effect of desensitizing agents previously to in-office dental bleaching, evaluating pain intensity and if the desensitizing agents influence the effectiveness of tooth whitening. For this, two following hypotheses were postulated: the desensitizing agent will reduce the soreness resulting from tooth whitening and the desensitizing agent will have no influence on the effectiveness of tooth whitening. The desensitizing agents utilize two mechanisms. Neutral Fluoride 2% (FN) (Flugel, DFL) act obliterate the dentin tubules, and the Potassium Nitrate with 2% sodium fluoride (NP) (Desensibilize KF 2%, FGM) act by blockage of pulp enervation reduction nociceptor sensorial excitability. In total, 30 volunteers were evaluated, and witch one received the four groups of studying, two desensitizing agents and two placebo, randomly distributed between the quadrant. The desensitizing agent corresponding to each group was applied (NP and Placebo I for 10 minutes; FN and Placebo II for 4 minutes) in each arch, with carefully for each substance remained in their quadrant. The desensitizing agents was applied before the bleaching procedure with hydrogen peroxide 35%. Tree sessions was performed for the bleaching, with one week interval between sessions. The gel remained in contact with the teeth for 15 minutes, and was performed three times at each session result in in 45 minutes per session. To evaluate dental sensitivity it was utilizing a numerical scale with intensity scores that ranged from 0 to 4 (0 = no sensitivity, 1 = light sensitivity, 2 = moderate sensitivity, 3 = considerable sensitivity and 4 = intense sensitivity). The color evaluation was performed by an objective analysis utilizing a spectrophotometer (Easyshade, Vivadent) and was made before witch session, with a silicon guide to evaluate the color at different times at the same place. The color variation (?E) were submitted to an analysis of one way variance (ANOVA) and the Tukey test (p<0,05). Pain intensity was submitted to a two-way ANOVA analysis (time and desensitizing agent). Two of the patients discontinued treatment due to hypersensitivity, and they aren¿t including in the statistical analises. The desensitizing products used before the treatment did not influence the final treatment efficacy. The diference of colors ate the third week was significantly different from que diference colors obtained ate the fish week of bleaching. For painful sensations during the treatments a significant difference for desensitizing agent and time was demonstrated, but the interaction of the two factors was not significant. The Tukey test indicated differences between NP and the Placebo I, but there was no significant difference between neutral FN and the placebo II. The pain intensity was lower with the use of the gel during the bleaching compared to the days after treatment, regardless of the desensitizing agent being used. It can be concluded that 5% potassium nitrate with sodium fluoride 2%, applied before in-office bleaching can reduced sensitivity intensity and the use of desensitizing gel prior to bleaching does not alter the effectiveness of whitening / Mestrado / Dentística / Mestra em Clínica Odontológica
|
33 |
Avaliação in vivo da efetividade e do pH de géis clareadores no clareamento em consultório em 12 meses de acompanhamento / In vivo evaluation of the effectiveness and pH of bleaching gels for in office whitening- 12 months follow-upDelafiori, Ana Carolina Trentino 10 December 2015 (has links)
O objetivo deste estudo in vivo, internacional, randomizado e duplo cedo foi avaliar comparativamente a efetividade e o pH de diferentes géis clareadores na técnica de clareamento em consultório, com e sem o emprego de fonte de luz híbrida em função do grau de alteração de cor, sensibilidade e manutenção do tratamento ao longo de 12 meses de acompanhamento. Foram selecionados 48 voluntários de acordo com os critérios de inclusão e exclusão. Os pacientes foram divididos, de forma randomizada, em 4 grupos de 12 participantes cada, onde: Grupo EXP10 5 aplicações do gel de peróxido de hidrogênio a 10% (Gel Experimental DMC Equipamentos) e ativação de luz híbrida de LED (violeta)/Laser (Experimental DMC Equipamentos) com 7′ e 30″ por aplicação, com tempo total de 37′30; Grupo LP15 5 aplicações do gel de peróxido de hidrogênio 15% (Lase Peroxide Lite DMC Equipamentos) seguindo mesmo protocolo do grupo EXP10; Grupo TB35LH 3 aplicações do gel de peróxido de hidrogênio a 35% (Total Blanc Office - DFL) e ativação de luz híbrida de LED (azul)/Laser (Whitening Lase II DMC Equipamentos) de 7′ e 30″ por aplicação, com tempo total de 22′30″; Grupo TB35 3 aplicações do gel de peróxido de hidrogênio a 35% (Total Blanc Office - DFL) sem ativação com fonte de luz, totalizando 45″. A determinação dos valores de pH foi realizada com o peagômetro digital (Sentron Model 1001, Sentron) nos tempos inicial e após o término do protocolo clareador. A aferição da cor foi feita com espectofotômetro VITA Easyshade antes do clareamento, após 24 horas, 1 semana, 1, 6 e 12 meses. A sensibilidade dentária e grau de satisfação dos pacientes foram avaliados por meio do questionário VAS e IPS antes, imediatamente após o clareamento, 24 horas e uma semana após. Os resultados da alteração do pH receberam tratamento estatístico pela ANOVA e teste de Bonferroni a 0,05%. Os resultados indicaram que o pH aumentou do momento inicial para o final para todos os protocolos. Não houve diferenças significativas entre os protocolos TB35 e TB35LH em nenhum dos momentos, e o pH médio do grupo EXP10 foi maior em comparação aos outros três grupos nos dois momentos avaliados. Os resultados do ΔE receberam tratamento estatístico pela ANOVA e teste de Bonferroni a 0,05%. Os resultados indicaram que não houve diferença significativa entre os grupos LP15, TB35 e TB35LH. O ΔE médio observado após 24 horas foi estatisticamente maior que para os outros tempos (inicial, 1 semana, 1 mês, 6 e 12 meses). Para análise da sensibilidade foi construído um modelo linear misto e atribuídos postos (ranks) aos valores de Δ e teste de Bonferroni a 0,05% para comparações pareadas. Não houve diferença nos valores da sensibilidade imediatamente e 24 horas após o tratamento, com relação ao momento inicial. Houve diferença significativa entre Δ1 e Δ3 indicando que a sensação de dor após uma semana do tratamento foi menor do que as observadas nos instantes imediato e após 24 horas. Para os resultados de satisfação foi construído um modelo linear misto e atribuídos postos (ranks) e o Método de Bonferroni (0,05%) foi utilizado para as comparações pareadas do efeito de tempo. Os resultados indicam queda nos níveis de satisfação entre os períodos imediato e um ano e entre os períodos 24 horas e um ano. Todos os géis clareadores apresentaram mínima variação do pH nos tempos avaliados, entretanto houve um aumento do pH da primeira para a última aplicação em todos os grupos estudados e o grupo EXP10 apresentou os maiores valores de pH seguido do LP15, TB35LH e TB35 apresentaram os valores mais baixos de pH. Os grupos LP15, TB35 e TB35LH apresentaram menor variação da cor ao longo de 12 meses de acompanhamento. O efeito do protocolo clareador não influenciou a sensibilidade dos pacientes e após uma semana a sensibilidade retornaram aos níveis normais. O nível de satisfação dos pacientes foi significativo em relação ao tempo e não aos protocolos clareadores, os pacientes do grupo TB35 mostraram-se mais insatisfeitos ao longo da pesquisa. / The aim of the present in vivo study, international, randomized and double early was to comparatively evaluate the effectiveness and pH of different bleaching agents for in office bleaching techniques, with and without the use of a hybrid light source depending on the degree of color change, sensitivity and maintenance treatment over a 12-month follow-up. Selected were 48 volunteers according to the inclusion and exclusion criteria. The patients were randomly divided into 4 groups of 12 participants each, where: EXP Group10- 5 applications of 10% hydrogen peroxide gel (Experimental Gel - Equipment DMC) and activation of hybrid LED light (violet) / Laser (Experimental - Equipment DMC) with 7 ″and 30″ per application, with a total time of 37′30; LP15 Group- 5 applications of 15% hydrogen peroxide gel (Lase Peroxide Lite - Equipment DMC) following the same protocol of the EXP10 Group; TB35LH Group- 3 applications of 35% hydrogen peroxide gel (of Blanc Office - DFL) and activation of hybrid LED light (blue) / Laser (Whitening Lase II - DMC Equipment) 7 ″and 30″ per application, with a total time of 22′30; TB35 Group - 3 applications of 35% hydrogen peroxide gel (of Blanc Office - DFL) without light activation, totaling 45 ″. The determination of pH was carried out with a digital pH meter (Sentron Model 1001, Sentron) in the initial times and after the bleaching protocol. The color measurement was made with a VITA Easyshade spectrophotometer before the treatment, after 24 hours, 1 week, 1, 6 and 12 months. Tooth sensitivity and degree of patient satisfaction were assessed by the VAS IPS questionnaire before, immediately after bleaching, 24 hours and one week after. The pH change results were statistically processed by the ANOVA and Bonferroni tests at 0.05%. The results indicated that the pH increased from baseline to the end for all protocols. There were no significant differences between the TB35 and TB35LH protocols in any of the times, and the average pH of the EXP10 group was higher compared to the other three groups in the two periods evaluated. The results of the ΔE received statistical analysis by ANOVA and Bonferroni testing at 0.05%. The results indicated that there was no significant difference between the LP15, TB35 and TB35LH Groups. The average ΔE observed after 24 hours was statistically greater than for the other times (initial, 1 week, 1 month, 6 months and 12 months). For the sensitivity analysis, a mixed linear model was constructed and assigned points (ranks) for Δ values and the Bonferroni test at 0.05% was used for paired comparisons. There was no difference in sensitivity values immediately and 24 hours after treatment with the initial time. There was a significant difference between Δ1 and Δ3 indicating that the sensation of pain after one week of treatment was lower than those observed in the immediate times and after 24 hours. For the results of satisfaction, a mixed linear model was constructed and assigned points (ranks) and the Bonferroni method (0.05%) was used for paired comparisons of time effects. The results indicate a reduction in the levels of satisfaction between the immediate and one year periods and periods between 24 hours and one year. All bleaching gels showed minimal pH variation in the evaluated times, however, there was an increase in pH from the first to the last application in all groups and the EXP Group showed the highest pH followed by the LP15, TB35LH and TB35 Groups which presented lower pH values. The LP15, TB35 and TB35LH Groups showed less color variation over a 12 month follow-up. The effect of the bleaching protocol did not affect the sensitivity of patients and after a week, and the sensitivity returned to normal levels. The level of patient satisfaction was significant in relation to the time and not the bleaching protocols. The patients in the TB35 Group were more dissatisfied during the research.
|
34 |
Proposta de tratamento para hipersensibilidade dentinária à base de biovidro em diferentes veículos. Estudo morfológico in vitro / Proposal of treatment for dentinal hypersensitivity based on bioglass in different vehicles. Morphological study in vitroElmadjian, Thais Regina 24 April 2014 (has links)
Os tratamentos para a hipersensibilidade dentinária (HD) não exibem efetividade em longo prazo, o que justifica a busca por novos tratamentos. O uso do biovidro por ser um material bioestimulador com capacidade de promover deposição de hidroxiapatita seria um tratamento promissor na redução da HD em longo prazo. Neste sentido, o objetivo deste estudo foi comparar in vitro o efeito do pó de biovidro associado a diferentes veículos na obliteração de túbulos dentinários expostos antes e após desafio erosão/abrasão (DEA). Dois fragmentos da porção cervical da raiz de 36 dentes humanos uniradiculares tiveram o cemento removido com curetas periodontais. A seguir, para mimetizar a HD, a dentina exposta foi tratada com ácido fosfórico a 37% por 1 min para abertura dos túbulos. Os fragmentos foram distribuídos nos seguintes grupos experimentais (n=12): G1: Controle: nenhum tratamento adicional; G2: biovidro com ácido fosfórico a 30%; G3: Gluma Desensitizer; G4: Gluma Desensitizer com biovidro; G5: irradiação com laser de Nd:YAG e G6: biovidro com irradiação com o laser de Nd:YAG. A irradiação com laser de Nd:YAG (1.064 nm; 1,0 W, 15 Hz, 66 mJ) foi realizada por 10 s por quatro vezes, com intervalos de 10 s, no modo contato e em varredura. Após a realização dos tratamentos dos diferentes grupos experimentais todos os espécimes ficaram armazenados em saliva artificial por 14 dias. Os dois fragmentos de uma mesma raiz foram submetidos ao mesmo tratamento e, de forma aleatória, um fragmento foi submetido ao DEA e o outro não. Este desafio foi realizado por meio da imersão dos espécimes em ácido cítrico a 1 % (pH 3,75), por 2 min, seguido da imersão em 15 ml de saliva artificial por 60 min. Após, os espécimes foram submetidos à escovação (270 ciclos em suspensão de dentifrício e saliva artificial para cada espécime) e à lavagem ao final deste DEA. Estes procedimentos foram repetidos 3 vezes ao dia por 3 dias. Então, estes espécimes foram armazenados em saliva artificial por 24 h. Após as incubações em saliva artificial todos os espécimes dos diferentes grupos experimentais foram preparados para análise morfológica por microscopia eletrônica de varredura (MEV). As eletromicrografias de varredura foram analisadas qualitativamente e quantitativamente, onde a área relativa de túbulos abertos em relação à área total das imagens com e sem DEA foram comparadas pelo teste ANOVA complementado pelo teste de Tukey (p<0,05). As maiores alterações morfológicas da dentina apareceram nos grupos Nd:YAG e o grupo biovidro + ácido fosfórico a 30%. Os grupos Nd:YAG não foram considerados na análise qualitativa porque a irradiação não aconteceu de forma homogênea. O grupo Gluma sem DEA apresentou área relativa de túbulos abertos significantemente menor que todos os outros grupos com e sem DEA. Houve uma tendência de redução de área relativa de túbulos dentinários abertos nos grupos com biovidro após o DEA, especialmente no grupo biovidro + ácido fosfórico a 30%. Conclui-se que o pó de biovidro nos diferentes veículos testados não foi capaz de induzir a obliteração dos túbulos dentinários expostos. / Treatments for dentin hypersensitivity (DH) do not exhibit long-term effectiveness, what boost the search for new treatments. The use of bioglass that is a biostimulator material with the ability to promote hydroxyapatite deposition would be a promising treatment for long term DH reduction. In this sense, the aim of this study was to compare the in vitro effect of a bioglass powder in different vehicles for closing exposed dentinal tubules before and after an erosion / abrasion challenge. Two fragments of the cervical portion of the root were obtained from 36 single-rooted human teeth. The cementum was removed with periodontal curettes. Then, to mimic the DH, the dentin was treated with 37% phosphoric acid for 1 min to open the tubules. The fragments were assigned to two experimental groups (n = 12): G1: Control: no additional treatment; G2: bioglass with 30% phosphoric acid, G3: Gluma Desensitizer; G4: Gluma Desensitizer with bioglass; G5: Nd:YAG laser irradiation and G6: bioglass with Nd:YAG laser irradiation. Irradiation was performed with Nd: YAG laser (1.064 nm, 1.0 W, 15 Hz, 66 mJ, 10s, four times with 10s- intervals between them) in scanning and contact mode. After the treatments, all specimens from different experimental groups were stored into artificial saliva for 14 days. The two fragments of the same roots received the same treatment and at random, one fragment was submitted to erosion/abrasion challenge and the other not. This challenge was carried out by the immersion of the specimens into a 1% citric acid solution (pH 3.75) for 2 min, followed by immersion into 15 ml of artificial saliva for 60 min. Next, the specimens were submitted to brushing (270 cycles in slurry of toothpaste and artificial saliva for each specimen) and washed in the end of this challenge. These procedures were repeated three times a day for 3 days. Then, the specimens were stored in artificial saliva for 24 h. After incubations in artificial saliva all specimens of different experimental groups were prepared for morphological analysis by scanning electron microscopy (SEM). The scanning electron micrographs were analyzed qualitatively and quantitatively, and the relative area of open tubules in relation to the total area of the images with and without the erosion/abrasion challenge were compared by using the Student´s t test (p < 0.05). The major morphological changes of the dentine were observed in the Nd:YAG groups and in the bioglass + 30% phosphoric acid group. The Nd:YAG groups were not considered for qualitative analysis because irradiation was uneven. The Gluma group without erosion/abrasion challenge showed relative area of open tubules significantly lower than those of all other groups with and without erosion/abrasion challenge. We conclude that the bioglass powder in different vehicles did not induce obliteration of exposed dentinal tubules.
|
35 |
Influência da espessura da cerâmica, do tempo de fotopolimerização e do cimento resinoso na resistência de união à microtração de uma cerâmica vítrea cimentada à dentina humana /Barca, Diana Capelli. January 2010 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Henrique Cerveira Netto / Banca: Rodrigo Othavio de Assunção e Souza / Resumo: Este estudo avaliou a influência da espessura da cerâmica, do tempo e tipo de fotopolimerização do cimento resinoso na resistência da união entre uma cerâmica vítrea e a dentina coronária humana. A hipótese é a de que o tipo e o tempo de fotopolimerização do agente cimentante e a espessura da cerâmica influenciem na resistência de união entre cimento e dentina. Foram selecionados cento e doze dentes molares humanos hígidos que foram incluídos em resina acrílica e tiveram a superfície oclusal cortadas em máquina Labcut, expondo a dentina planificada. Dois grupos foram tiveram a dentina condicionada com ácido fosfórico 37% lavada e aplicado adesivo (Excite, Ivoclar) fotopolimerizando por 20s. No grupo controle (n=16), utilizou-se cimento auto-adesivo. Foram confeccionados cento e doze blocos (6 x 6 mm) de cerâmica feldspática (Vita PM9) com três espessuras: 1, 2 e 3 mm que tiveram a superfície de cimentação tratad a com ácido fluorídrico 10%, lavada, seca e silanizada. Os blocos cerâmicos foram cimentados, de acordo com o grupo experimental: Variolink II (Ivoclar Vivadent); e fotopolimerizados com LED por 40 ou 80 segundos de fotopolimerização ou cimento Multilink II (no grupo controle). Assim, formaram-se sete grupos (n=16). Os espécimes foram armazenados em água destilada (37°C) por 24 horas e seccionados em dois eixos, X e Y, para a obtenção dos espécimes. Cada grupo (N=16) foi subdividido em 2 (n=8) onde um grupo foi termociclado e o outro submetido ao ensaio de microtração 24 horas após a cimentação. Esse palito (cerâmica/dente) foi fixado no dispositivo de microtração Erios, levado à máquina de ensaio universal e testado com velocidade de 1 mm/min. Os valores médios obtidos (MPa) foram à análise de Variáveis ANOVA 3- fatores, teste de Dunnett e ao teste de Tukey (5%). A resistência adesiva foi significantemente influenciada pelos fatores... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the influence of the thickness of the ceramic, time and type of light curing resin cement on bond strength between a ceramic and glass human dentin. The hypothesis is that the type and time of curing luting agent and the thickness of the ceramic bearing on the bond strength between cement and dentin. We selected one hundred and twelve healthy human molar teeth were embedded in acrylic resin and were cut in the occlusal surface Labcut machine, exposing the dentin. Two groups have had to dentin conditioned with 37% phosphoric acid washed applied adhesive (Excite, Ivoclar) light cured for 20s. In the control group (n = 16), we used self-adhesive cement. We made one hundred and twelve blocks (6 x 6 mm) ceramic feldspathic (Vita PM9) with three thicknesses: 1, 2 and 3 mm that had cement surface treated with hydrofluoric acid 10%, washed, dried, and silanized. The ceramic blocks were cemented according to the experimental group: Variolink II (Ivoclar Vivadent) and cured with LED for 40 or 80 seconds of curing cement Multilink or II (control group). Thus, they formed seven groups (N = 16). The specimens were stored in distilled water (37 ° C) for 24 hours and sectioned in two axes, X and Y, to obtain the specimens. Each group (N = 16) was subdivided into two (n = 8) where a group was thermocycled and another test by microtensile 24 hours after cementation. This toothpick (ceramic / tooth) was mounted in microtensile Erios, led to a universal testing machine and tested at a speed of 1 mm / min. The average values (MPa) were the ANOVA analysis of three variables - factors, Dunnett test and Tukey test (5%). The bond strength was significantly influenced by light irradiation time, thickness of the ceramic thermal cycling / Mestre
|
36 |
Eficácia de um agente dessensibilizante experimental: ensaio clínico duplocego, controlado e randomizado / Efficacy of an experimental desensitizing gel: double-blind, controlled and randomized clinical trialFerrari, Wesley Fernando 23 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2019-03-12T21:37:08Z
No. of bitstreams: 2
Wesley_Ferrari_2018.pdf: 5292494 bytes, checksum: 80e420551cea7ffdde2bfbfeff0d10eb (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2019-03-12T21:37:08Z (GMT). No. of bitstreams: 2
Wesley_Ferrari_2018.pdf: 5292494 bytes, checksum: 80e420551cea7ffdde2bfbfeff0d10eb (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2018-03-23 / Aims: Evaluate the efficacy of dental bleaching and the tooth sensitivity during and after the
procedure using a Potassium Nitrate and Sodium Fluoride based desensitizer gel, with or
without Chitosan microparticles. Methods and Materials: Forty-two patients with a minimum
A2 degree of saturation were selected, divided into two groups (n = 21): DKF - Potassium
Nitrate with Sodium Fluoride and DKF CHI - Potassium Nitrate with Sodium Fluoride plus
Chitosan microparticles. Dental bleaching was performed in the upper arch, using 35%
Hydrogen Peroxide in a single session, with three applications of 15 minutes each. The
desensitizing gel was applied before the treatment and remained on the enamel for 10 minutes
in both groups. Tooth sensitivity (TS) was recorded by participants by means of scores while
the bleaching gel was in contact with the teeth (5, 10, 15, 20, 25, 30, 35, 40 and 45 minutes),
as well as 1, 24 and 48 hours after application. The shade evaluation was performed at
baseline and seven days after bleaching. TS was evaluated by the Mann-Whitney test (p
<0.05). The Kruskal-Wallis test (p <0.05) was used to assess the degree of bleaching. Results:
At the 40, 45 minute and 1 hour evaluation periods, the sensitivity levels of the DFK CHI
group were significantly lower in relation to the DKF group. Regarding the shade level, there
was no significant interference in the outcome for both groups evaluated. Conclusions: the
addition of chitosan microparticles to the desensitizing agent decreases sensitivity during and
after tooth bleaching without interfering on the bleaching efficacy.Clinical relevance: the use
of a desensitizing agent with chitosan microparticles prior to dental bleaching may decrease
dentin sensitivity, which is the most common side effect associated with tooth bleaching. / Objetivos: avaliar a efetividade do clareamento dental profissional e a intensidade da
sensibilidade durante e após o clareamento, utilizando um dessensibilizante à base de Nitrato
de Potássio e Fluoreto de Sódio, acrescido ou não de micropartículas de Quitosana.
Metodologia: foram selecionados 42 pacientes com grau de saturação dental mínima A2,
divididos em dois grupos (n=21): DKF – Nitrato de Potássio com Fluoreto de Sódio e DKF
QUI – Nitrato de Potássio com Fluoreto de Sódio acrescido de micropartículas de Quitosana.
O clareamento foi realizado na arcada superior, com o uso de Peróxido de Hidrogênio a 35%
em sessão única, com três aplicações de 15 minutos cada. O gel dessensibilizante foi aplicado
previamente ao tratamento e permaneceu sobre o esmalte por 10 minutos, em ambos os
grupos. O grau de sensibilidade (GS) foi anotado pelos pacientes por meio de escores, durante
o tempo em que o gel clareador esteve em contato com os dentes (5, 10, 15, 20, 25, 30, 35, 40
e 45 minutos), assim como 1, 24 e 48 horas após a aplicação. O grau de saturação da cor foi
avaliado no início e sete dias depois do clareamento. O GS foi avaliado pelo teste de Mann-
Whitney (p<0.05). Para a avaliação do grau de clareamento, foi aplicado o teste de Kruskal-
Wallis (p<0.05). Resultados: nos períodos de avaliação de 40, 45 minutos e 1 hora, os níveis
de sensibilidade do grupo DFK QUI foram significativamente menores em relação ao grupo
DKF. No que se refere ao grau de clareamento, não houve interferência significativa no
resultado para ambos os grupos avaliados. Conclusões: a adição de micropartículas de
Quitosana ao agente dessensibilizante diminui a sensibilidade durante e após o clareamento
dental sem interferir no grau de clareamento.Relevância clínica: o uso prévio de um agente
dessensibilizante com micropartículas de Quitosana pode diminuir a sensibilidade dentinária,
que é o efeito colateral mais comum associado ao clareamento dental.
|
37 |
Efetividade e sensibilidade ao clareamento dental caseiro realizado com peróxido de hidrogênio 4% e 10%: estudo clínico randomizado triplo cego / Effectiveness and dental sensitivity to at-home bleaching carried out with 4% and 10% hydrogen peroxide: a randomized, triple blind clinical trialChemin, Kaprice 17 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:03Z (GMT). No. of bitstreams: 1
Kaprice Chemin.pdf: 2800231 bytes, checksum: 6bb669e8add966b732aeb8523962bf60 (MD5)
Previous issue date: 2016-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to clinically evaluate the effectiveness, stability of color and dental sensitivity of at-home dental bleaching with 4% and 10% hydrogen peroxide (H2O2). For this study, 78 patients were selected according to the inclusion and exclusion criteria, with central maxillary incisors A2 or darker, compared to Vita Classical shade guide (Vita Zahnfabrik, Bad Säckingen, Germany), and they were randomized into two groups: G10% – 10% H2O2 (White Class with Calcium 10% - FGM, Joinville, SC, Brazil) and G4% – 4% H2O2 (White Class with Calcium 4% - FGM, Joinville, SC, Brazil). The bleaching was carried out with White Class with Calcium, FGM, Joinville, SC, Brazil) for a period of 30 minutes twice a day for two weeks for both concentrations. The color was assessed by Vita Classical (Vita Zahnfabrik, Bad Säckingen, Germany), Vita Bleachedguide 3D-MASTER (Vita Zahnfabrik) and spectrophotometer Vita Easyshade (Vita Zahnfabrik, Bad Säckingen, Germany) initially during bleaching (1st and 2nd weeks) and after this bleaching procedure (1 month). The tooth sensitivity was recorded by the patients, using a numeric rating scale (NRS, 0-4) and visual analogue scale (VAS, 0-10). We carried out the Mann-Whitney test for contrast of means (α=0.05). The tooth sensitivity was evaluated by Chi-square test and the intensity of tooth sensitivity was evaluated by Mann-Whitney test (α=0.05) for both scales. Data from ΔSGU and ΔE showed an effectiveness of dental bleaching in both groups after two weeks of treatment. The prevalence of tooth sensitivity was higher in the group that used 10% H2O2. It can be concluded that at-home bleaching is effective for both groups, and 4% H2O2 decreased the absolute risk intensity of tooth sensitivity in at-home dental bleaching. / O objetivo deste estudo foi avaliar clinicamente a efetividade, estabilidade da cor, sensibilidade dental causada pelo clareamento caseiro realizado com peróxido de hidrogênio (H2O2) 4% e 10%. Foram selecionados 78 pacientes de acordo com os critérios de inclusão e exclusão, com os incisivos centrais superiores com a cor A2 ou mais escuros, por comparação com a escala Vita Classical (Vita Zahnfabrik, Bad Säckingen, Alemanha) e aleatorizados em dois grupos: G10% – H2O2 10% (White Class com Cálcio 10% - FGM, Joinville, SC, Brasil) e G4% – H2O2 4% (White Class com Cálcio 4% - FGM, Joinville, SC, Brasil). O clareamento foi realizado pelo período de 30 min, 2 vezes ao dia, durante 14 dias em ambas as concentrações. A cor foi avaliada por meio das escalas Vita Classical, Vita Bleachedguide 3D-MASTER (Vita Zahnfabrik) e espectrofotômetro Vita Easyshade (Vita Zahnfabrik, Bad Säckingen, Alemanha), inicialmente, durante o clareamento (1ª e 2ª semanas) e 1 mês após o tratamento clareador. A sensibilidade dental foi registrada pelos próprios pacientes através da escala numérica analógica (NRS, 0-4) e escala visual analógica (VAS, 0-10). Foi realizado o teste de Mann-Whitney para o contraste das médias (α=0,05). A sensibilidade dental foi avaliada pelo teste Qui-quadrado e a intensidade da sensibilidade dental foi avaliada pelo teste Mann-Whitney (α=0,05) para ambas as escalas. Os dados de variação de unidades de escala Vita (ΔUEV) e variação de cor (ΔE) mostraram efetividade do clareamento dental em ambos os grupos após duas semanas de tratamento (p<0,05). O risco absoluto de sensibilidade dental foi maior para o grupo que utilizou H2O2 10%. Pode-se concluir que a efetividade do clareamento dental caseiro com H2O2 4% e 10% são semelhantes, porém H2O2 4% diminuiu o risco absoluto e a intensidade da sensibilidade dental durante o clareamento dental caseiro.
|
38 |
AVALIAÇÃO CLÍNICA DA EFETIVIDADE E DA SENSIBILIDADE AO CLAREAMENTO DENTAL EM PACIENTES COM RESTAURAÇÕES ESTÉTICAS / In-office bleaching effectiveness and sensitivity in patients with esthetic restorationsBonafé, Elize Tatiane Ribeiro 14 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:16Z (GMT). No. of bitstreams: 1
Elize Bonafe.pdf: 1682408 bytes, checksum: e0368d62fba134c88312151976525ab7 (MD5)
Previous issue date: 2012-02-14 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Dental bleaching in patients with esthetic restoration is a clinical reality, but there are no studies assessing its effectiveness and post-operative sensitivity. The aim of this study was to evaluate the effectiveness of a bleaching agent and the sensitivity associated to dental bleaching in patients with esthetic restorations. Sixty patients were selected and divided in 2 groups: H (patients with no restoration) and R (patients with esthetic restoration). The groups H and R were allocated into subgroups depending on the prior application of a desensitizing agent (D - with desensitizing; S - without desensitizing), resulting in four subgroups: HS, HD, RS and RD. It was performed two sessions of three applications of 15 minutes each with 35% hydrogen peroxide for all the patients. The color was assessed by the visual scale and a spectrophotometer prior to bleaching, one week after the each session and six months after the end of the treatment. The patients recorded their sensitivity perception on a NRS scale immediately after bleaching and up to 7 days after each session. The bleaching effectiveness was evaluated at each recall by one way ANOVA and Tukey’s tests (α=0.05). The percentage of patients with dental sensitivity was evaluated by Fisher’s Exact Test and intensity differences among groups were compared with Mann-Whitney U test (α=0.05). The results showed a high prevalence of sensitivity associated to dental bleaching. The sensitivity rate was higher for the groups with esthetic restoration but the application of a desensitizing agent significantly decreased the intensity of sensitivity in all groups (p<0,05). It was noted the same effectiveness of bleaching for all the groups and in the 6-month evaluation it was found color stability. It was concluded that patients with aesthetic restorations did not have higher prevalence of sensitivity associated to dental bleaching, however, its intensity was greater. The application of a desensitizing agent decreased the sensitivity intensity in patients with and without esthetic restorations. / A realização de clareamento dental em pacientes que possuem restaurações estéticas é uma realidade clínica, no entanto, não foram encontrados trabalhos que tenham como objetivo a avaliação da efetividade do clareamento e da sensibilidade durante o tratamento e pós-operatória nesses casos. O objetivo desta pesquisa foi avaliar a efetividade de um agente clareador e a sensibilidade associada ao clareamento dental em pacientes com restaurações estéticas. Sessenta pacientes foram selecionados e divididos em 2 grupos: pacientes com dentes hígidos (H) e pacientes com restaurações estéticas (R). Os grupos H e R foram alocados em subgrupos dependendo da aplicação prévia de um agente dessensibilizante (D) ou de um agente placebo (S), assim, foram formados os quatro subgrupos estudados: HS, HD, RS e RD. Em todos os pacientes foram realizadas duas sessões com três aplicações de 15 minutos de um agente clareador à base de peróxido de hidrogênio 35%. A cor foi avaliada com uma escala visual e um espectrofotômetro previamente ao clareamento,1 semana após cada sessão, e 6 meses após o término do tratamento. Os pacientes registraram a ocorrência de sensibilidade em uma escala NRS imediatamente e durante os 7 dias seqüentes ao término de cada sessão. A efetividade do clareamento foi avaliada, em cada período, com Análise de Variância de um fator e pós-teste de Tukey (α=0.05). O percentual de pacientes com sensibilidade dental foi avaliado com Teste Exato de Fisher e a comparação da sua intensidade entre os grupos foi realizada com o teste de Mann Whitney U (α=0.05). Os resultados demonstraram que houve alta prevalência de sensibilidade associada ao clareamento dental. A intensidade de sensibilidade foi maior para os grupos com restauração e a aplicação de um agente dessensibilizante diminuiu significantemente essa intensidade em todos os grupos (p<0,05). Foi constatada a mesma efetividade de tratamento para todos os grupos e em 6 meses de avaliação houve estabilidade de cor. Concluiu-se que pacientes com a presença de restaurações estéticas não apresentam maior prevalência de sensibilidade associada ao clareamento, no entanto, sua intensidade é maior. A aplicação de um dessensibilizante promoveu diminuição da intensidade de sensibilidade tanto em pacientes com dentes hígidos, quanto em pacientes com restaurações estéticas.
|
39 |
ESTUDO LABORATORIAL E CLÍNICO DE DOIS AGENTES CLAREADORES EM PACIENTES COM APARELHO ORTODÔNTICO FIXO / Clinical and laboratorial study of two types of bleaching agents with fixal orthodontic applianceGordillo, Luis Alfonso Arana 04 June 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:29Z (GMT). No. of bitstreams: 1
Luis Alfonso Arana.pdf: 2635884 bytes, checksum: d4307fc168407477c95f82f579d9612f (MD5)
Previous issue date: 2013-06-04 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This study was evaluated clinically and laboratorially the effects of the application of two types of bleaching agents, Tréswhite Ortho (TWO) and Trés white Supreme (TWS) in patients with fixal orthodontic appliance. In the laboratorial study 50 healthy human teeth were used. For the microhardness, roughness and AFM tests, 60 enamel fragments, obtained from the crowns of 20 molars were divided depending on the treatment TWO and TWS (n=10). For each test it was performed a baseline measurement and a one week after treatment measurement. For the permeability
test 30 healthy human premolars were used, divided into three groups: TWO, TWS and CTRL (SA). The variability of the pH of TWO and TWS was analyzed. For the clinical study 40 patients with fixal orthodontic appliance were recruited and divided into two groups TWO and TWS (n=20) , for each patient a color measurement was performed before the treatment and one week after the treatment; for the evaluation of sensitivity the patients received orientation in order to fill a NRS101 form before, during and after the treatment. After these tests, the normality of the obtained results was analyzed by using Kolmogorov Smirnov and Shapiro-Wilk tests. In the laboratorial assessment, there was a significant reduction on the microhardness values when compared with the initial measurements; for the roughness test there was a significant decrease on the (Ra) values when compared with the initial values for the TWO group, for the TWS group non significant alterations were observed; on
the permeability test the TWS group obtained higher values of the mg/mL concentration when compared to TWO, which presented higher values than CTRL group. The pH values of both groups were statistically different with tendency to
alkalinity and acidity for the groups TWO and TWS respectively. On the clinical study there was a significant decrease of tooth color values for both groups when
compared with the initial values, and showed non-significant differences between groups when compared to each other; for dental sensitivity, when each of the evaluated days were compared to day 0, there was a significant increase for both
groups, however, non-significant statistical differences were also found. It was concluded that the tested products on the laboratorial assessment can modify the superficial properties of the enamel, and have the capacity of permeabilizing the
dentin-enamel complex until reaching the pulp chamber, also showing variability on the pH values due to the time of application, clinically, both products showed treatment effectiveness and a increase of tooth sensitivity. / Este estudo avaliou laboratorial e clinicamente dois agentes clareadores (Treswhite Ortho (TWO) e Tres white Supreme (TWS)) em pacientes com aparelho ortodôntico fixo. No estudo laboratorial, foram utilizados 50 dentes humanos hígidos. Para os testes de microdureza, rugosidade e AFM foram utilizados 60 fragmentos de esmalte, obtidos a partir das coroas de 20 molares hígidos; divididos segundo o
tratamento, TWO e TWS (n=10). Para cada teste, foram realizadas mensurações de linha base e uma semana após o tratamento; sendo para o teste de permeabilidade
utilizados 30 pré-molares humanos hígidos, divididos em três grupos: TWO, TWS e CTRL (SA). A variação do pH dos produtos TWO e TWS foi analisada. No estudo clínico, foram recrutados 40 pacientes com aparelhos ortodônticos fixos, divididos em dois grupos, TWO e TWS (n=20). Em cada paciente foi realizado um registro de cor antes do tratamento e uma semana após o mesmo; para avaliar a sensibilidade
dental os pacientes foram orientados a preencher um formulário NRS101, antes e durante o tratamento. Após os testes, a normalidade dos dados obtidos foi analisada
empregando-se o teste de Kolmogorov Smirnov e Shapiro-Wilk. No estudo laboratorial, a microdureza sofreu uma diminuição significativa em relação aos valores finais comparados com os valores iniciai; para o teste de rugosidade, houve uma diminuição significativa nos valores de (Ra) iniciais e finais para o grupo TWO. O grupo TWS não sofreu alterações significativas; no teste de permeabilidade, o
grupo TWS obteve valores de mg/mL significativamente maiores ao grupo TWO, que foi significativamente maior ao grupo CTRL. Os valores de pH de ambos os grupos foram estatisticamente diferentes com tendências a alcalinização e acidificação para os grupos TWO e TWS respectivamente. No estudo clínico houve uma diminuição significativa da cor, para ambos os grupos, em relação aos valores iniciais sem
diferença significativa entre os grupos; para a sensibilidade ao comparar cada um dos dias testados com o dia 0 encontrou-se um aumento significativo para ambos os grupos porém, sem diferença estatística entre os mesmos. Concluiu-se que os
produtos testados num modelo de estudo laboratorial podem alterar as propriedades superficiais do esmalte; tem a capacidade de permeabilizar o complexo dentinaesmalte
até atingir a câmara pulpar e apresentam variação nos valores de pH, conforme o tempo de aplicação. No estudo clínico ambos os produtos demonstraram efetividade de tratamento e aumento na sensibilidade dentária.
|
40 |
SENSIBILIDADE DENTAL E EFETIVIDADE DE UM NOVO PROTOCOLO DE APLICAÇÃO DA TÉCNICA DE CLAREAMENTO ASSOCIADO COM APLICAÇÃO DE DESSENSIBILIZANTEVOCHIKOVSKI, Laína 19 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-24T14:25:47Z
No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Laína Vochikovski.pdf: 1715401 bytes, checksum: 00edb0ede542121164e6401f7a16d18a (MD5) / Made available in DSpace on 2018-07-24T14:25:47Z (GMT). No. of bitstreams: 2
license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5)
Laína Vochikovski.pdf: 1715401 bytes, checksum: 00edb0ede542121164e6401f7a16d18a (MD5)
Previous issue date: 2018-02-19 / O objetivo desse estudo foi avaliar a efetividade, estabilidade de cor, risco absoluto e a intensidade da sensibilidade dental (SD) advinda do clareamento dental associado com aplicação prévia de agente dessensibilizante. Trata-se de um estudo randomizado e paralelo, onde foram selecionados 80 voluntários segundo os critérios de inclusão/exclusão, os quais foram aleatorizados em dois grupos: clareamento associado (CA) e clareamento caseiro (CC). No grupo CA, previamente ao clareamento em consultório foi aplicado o gel dessensibilizante (Dessensibilize KF 2%, FGM) durante 10 min. Após foi realizada uma sessão de clareamento em consultório com H2O2 35% (Whiteness HP Maxx, FGM), sendo duas aplicações de 15 min cada. No dia seguinte, foi iniciado o clareamento caseiro com H2O2 4% (White Class com Cálcio 4%, FGM), pelo período de 30 min, duas vezes ao dia, durante três semanas. O grupo CC recebeu apenas o clareamento caseiro com H2O2 4% (White Class com Cálcio 4%, FGM), 30 min, duas vezes ao dia, durante três semanas. A cor foi registrada inicialmente, durante a fase ativa do clareamento (após a primeira, segunda e terceira semanas) e pós-clareamento (uma semana, um mês e seis meses pós-clareamento), com as escalas Vitapan Classical e Vita Bleachedguide 3D-Master, e espectrofotômetro Vita Easyshade. A SD foi registrada através da escala visual analógica (VAS 0-10) e escala de classificação numérica (NRS 0-4). A SD no grupo CA foi avaliada imediatamente, até uma hora e 24 h após a realização do clareamento dental em consultório e diariamente durante os 21 dias de clareamento caseiro. No grupo CC, a SD foi avaliada diariamente durante os 21 dias de clareamento. Os dados obtidos foram analisados através de testes estatísticos apropriados (α = 0,05). Não houve diferença significante entre os grupos para o risco absoluto da SD (p = 0,19). A intensidade de SD foi maior na 1ª semana para o grupo CA (p < 0,05), com redução ao longo do tratamento. O clareamento dental foi efetivo para ambos os grupos, não havendo diferença significativa entre eles quando a cor foi avaliada através da escala Vita Classical (p = 0,118) e pelo espectrofotômetro Vita Easyshade (p = 0,654). Houve diferença estatística entre os grupos quando a cor foi avaliada através da escala Vita Bleachedguide (p = 0,043). O grau de clareamento obtido através dos instrumentos utilizados se manteve estável após seis meses de tratamento para ambos os grupos (p > 0,05). Pode-se concluir que ambas as técnicas foram efetivas e estáveis após seis meses de tratamento, porém foi observado um maior grau de clareamento para a técnica associada com a escala Vita Bleachedguide. Não houve diferença no risco absoluto de SD entre as técnicas, porém a técnica associada resultou maior intensidade de SD. / The aim of this study was to clinically evaluate the effectiveness, stability of color, absolute risk and intensity of tooth sensitivity (TS) from tooth whitening combined with prior application of desensitizing agent. It was a randomized, parallel study, in which 80 patients were selected according to the inclusion/exclusion criteria, which were randomized into two groups: combined bleaching (CA) and at-home bleaching (CC). In the CA group, the desensitizing gel (Dessensibilize KF 2%, FGM, Joinville, SC, Brazil) was applied for 10 min prior to in-office bleaching. After an in-office bleaching session with 35% H2O2 (Whiteness HP Maxx, FGM), two 15-min applications were performed. The next day, at-home bleaching with 4% H2O2 (White Class with Calcium 4%, FGM) was started for 30 min twice daily for three weeks. The CC group received only at-home bleaching with 4% H2O2 (White Class with Calcium 4%, FGM), 30 min twice daily for three weeks. The color was initially recorded during the active phase of bleaching (after the first, second and third weeks) and post-bleaching (one week, one month and six months post-bleaching) with the Vita Classical (Vita Zahnfabrik) scales and Vita Bleachedguide 3D-Master (Vita Zahnfabrik), and spectrophotometer Vita Easyshade (Vita Zahnfabrik). The TS was recorded through visual analogue scale (VAS 0-10) and numerical scale (NRS 0-4). The TS in CA group was evaluated immediately, up to one hour and 24 h after dental bleaching in-office and daily during the 21 days of at-home bleaching. In the CC group, TS was evaluated daily during the 21 days of bleaching. The data obtained were analyzed using appropriate statistical tests (α = 0.05). There was no statistically significant difference between the groups for the absolute risk of TS (p = 0.19). The TS intensity was higher in the first week for the CA group (p <0.05), with reduction throughout the treatment. Dental bleaching was effective for both groups, and there was no significant statistical difference between them when the color was evaluated using the Vita Classical scale (p = 0.118) and the Vita Easyshade spectrophotometer (p = 0.654). There was a statistically significant difference between the groups when the color was evaluated through the Vita Bleachedguide scale (p = 0.043). The degree of bleaching obtained using the instruments used remained stable after six months of treatment for both groups (p> 0.05). It can be concluded that both techniques were effective and stable after six months of treatment, but a greater degree of bleaching was observed for the technique associated with the Vita Bleachedguide scale. There was no difference in the absolute risk of TS among the techniques, but the associated technique resulted in a higher TS intensity.
|
Page generated in 0.1061 seconds