• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • Tagged with
  • 40
  • 40
  • 31
  • 30
  • 22
  • 20
  • 20
  • 14
  • 14
  • 13
  • 11
  • 11
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Percepção de contraste e perdas neurais na esclerose múltipla / Contrast perception and neural losses in multiple sclerosis

Moura, Ana Laura de Araujo 08 December 2010 (has links)
Objetivos: Avaliar a integridade das vias magnocelular (M) e parvocelular (P) atraves da percepcao de contraste e avaliar a sensibilidade no campo visual e respostas no ERG multifocal, em pacientes com esclerose multipla. Métodos e Resultados: Foram avaliados 29 pacientes (20F; 9M; idade media = 35,76 }10,91 anos) com diagnostico de esclerose multipla (15 com historico de neurite optica). Todos os pacientes apresentavam acuidade visual entre 0 e 0,1 logMAR. A percepcao de contraste foi avaliada atraves da funcao de sensibilidade ao contraste (programa PSYCHO; Cambridge Research System), com os limiares medidos em 0.2, 0.5, 1.0, 1.9, 5.3, 9.7 e 19.4 ciclos por grau; e do teste do Pedestal (Pokorny & Smith, 1997). O campo visual foi medido com o Campimetro Automatico de Humphrey, algoritmo SITA, estrategia central 24-2. O ERGmf foi registrado, utilizando o sistema VERIS, com 103 hexagonos. A analise foi baseada nos valores de amplitude e latencia de N1 e P1 das respostas de seis regioes predeterminadas de acordo com o mapa sugerido por Garway-Heath et al (2000), para os kernels de primeira e segunda ordem. Os pacientes foram divididos em 2 grupos: NO (antecedente de neurite optica) e SNO (sem antecedente de neurite optica). Resultados: O grupo NO nao diferiu do grupo SNO em nenhum dos testes, exceto nas medidas de amplitude do kernel de segunda ordem no ERGmf (Tukey HSD Test, PostHoc). Todos os pacientes mostraram uma reducao na percepcao de contraste, quando comparados ao grupo controle. Os resultados diferiram significativamente do grupo controle em todas as frequencias espaciais avaliadas na funcao de sensibilidade ao contraste (p < 0.001; ANOVA), e nos dois paradigmas avaliados pelo teste do Pedestal (p <0.05 ANOVA de medidas repetidas). As respostas do kernel de primeira ordem do ERGmf para ambos os grupos, quando comparados com o grupo controle, nao apresentaram diferenca estatistica significativa para as regioes analisadas (p > 0.05; ANOVA de medidas repetidas). As respostas de amplitude dos pacientes, para o kernel de segunda ordem apresentaram-se diferentes do grupo controle, com significancia estatistica para as areas 2, 3, 4, 5 e 6 (p < 0.05; ANOVA de medidas repetidas). Os resultados do campo visual mostraram reducao de sensibilidade nos pacientes em estudo, comparados ao grupo controle, com diferenca estatisticamente significante para todas as regioes (p <0.05; ANOVA de medidas repetidas). Conclusões: Aumento nos limiares de deteccao de contraste foram encontrados nos pacientes com esclerose multipla, em ambos os testes. O padrao de perda nas varias frequencias espaciais e em ambos os paradigmas analisados no teste do Pedestal, sugere um comprometimento nao seletivo das vias visuais, afetando tanto a via parvo como a magnocelular. As alteracoes nas respostas do ERG multifocal detectadas apenas no kernel de segunda ordem poderiam estar relacionadas a danos retrogrados a camada de fibras nervosas da retina causados pela desmielinizacao. Nao foram encontradas correlacoes com as perdas de sensibilidade no campo visual / Purpose: To assess the integrity of the magnocellular (M) and parvocellular (P) pathways by measuring contrast perception and to evaluate the visual field and multifocal ERG responses in patients with multiple sclerosis. Methods: 29 patients (20F, 9M, mean age = 35.76 } 10.91 years) diagnosed with multiple sclerosis were evaluated (15 with optic neuritis). All patients had visual acuity between 0 and 0.1 logMAR. The contrast perception was assessed by the measurement of contrast sensitivity function (program PSYCHO, Cambridge Research System) using spatial frequencies 0.2, 0.5, 1.0, 1.9, 5.3, 9.7 and 19.4 cycles per degree and the pedestal test (Pokorny & Smith, 1997). The visual field was measured using the central 24-2 SITA algorithm of the Humphrey Field Analyzer. The mfERG was recorded using the Veris system with 103 hexagons in which N1 and P1 amplitude and latency values of six predetermined areas according to the map suggested by Garway-Heath et al (2000) were used (first and second order kernels). Patients were divided into two groups: NO (with optic neuritis) and SNO (without optic neuritis). Results: The NO group did not differ from the SNO in any of the tests except for the second order kernel amplitudes in the mfERG (Tukey HSD posthoc test). All patients showed a reduction in contrast perception compared to the control group. The patients results were significantly different from the control groups at all spatial frequencies tested (p <0.001, ANOVA), and for the two paradigms of the pedestal test (p <0.05, ANOVA). The first order kernel responses in the mfERG showed no significant difference for both patient groups when compared with the control group (p> 0.05, ANOVA). The second order kernel amplitudes were different between patients and controls, with statistical significance for areas 2, 3, 4, 5 and 6 (p <0.05, ANOVA). The visual field results showed sensitivity reductions in the patients compared to controls, which was statistically significant for all regions (p <0.05, ANOVA). Conclusions: Increased thresholds for contrast detection were found in patients with multiple sclerosis in both tests. The pattern of loss in the various spatial frequencies and in both test paradigms of the Pedestal suggests a non-selective impairment of the visual pathways affecting both the parvo and magnocellular pathways. Changes in multifocal ERG responses found only in the second order kernel may be related to retrograde damage of the nerve fiber layer of the retina caused by demyelization. No significant correlation with the visual field losses was found
12

Repercussões visuais da exposição ocupacional a uma mistura de solventes orgânicos: visão cromática e acromática em frentistas brasileiros / Visual repercussions of occupational exposure to a mixture of solvents: Chromatic and achromatic vision in brazilian gas station workers

Costa, Thiago Leiros 13 December 2010 (has links)
Objetivo: Avaliar repercussões da exposição ocupacional a uma mistura de solventes orgânicos sobre o desempenho visual de um grupo de frentistas. Método: Foram aplicados testes de ordenamento e discriminação de matizes, campo visual e sensibilidade ao contraste espacial de luminância em 25 frentistas (20 homens, M=36,4 anos, DP=8,9) e 25 controles sem histórico de exposição crônica a solventes (10 homens, M=33,8 anos, DP=8,8). As concentrações metabólitos urinários de tolueno (M=0,3 g/g de creatinina; DP=0,16) e xileno (M=0,1 g/g de creatinina; DP=0,02) e o tempo de trabalho (M=9,6 anos; DP=6,2) foram utilizados como indicativos da exposição dos frentistas. Os participantes foram submetidos a exame oftalmológico, e quando necessário, corrigir a acuidade visual para 20/20. Todas as medidas foram realizadas monocularmente com um olho escolhido ao acaso, com exceção do Potencial Visual Evocado Multifocal (PVEmf) e da campimetria. Para avaliar a visão de cores, utilizamos o Lanthony D15-d e Cambridge Colour Test 2.0. Na campimetria estática automatizada foi utilizado o protocolo branco-branco 24-2 do aparelho Humphrey Field Analyzer II-750i. A atividade elétrica visual cortical foi avaliada com o sistema de PVEmf Veris Science 5.2.4, utilizando um estímulo de 60 setores. A sensibilidade ao contraste espacial de luminância foi avaliada no teste Metropsis, para grades senoidais em 7 frequências espaciais de 0,2 a 20,0 cpg. Resultados: Os escores do grupo de frentistas e do grupo controle foram comparados pelo teste Mann-Whitney U. No teste de discriminação de cores (CCT), houve diferença estatística significativa entre controles e frentistas para a área total da elipse (p<0,01), elipticidade (p<0,05) e limiares nos eixos protan, deutan e tritan (p<0,05). No D15d houve diferença significativa entre os 8 dois grupos (p<0,01). Os dados da campimetria apresentaram diferenças significativas entre os dois grupos para as excentricidades de 90, 150 e 210, além dos valores de MD e PSD (p<0,05). Dos três frentistas avaliados com o PVEmf, todos apresentaram uma diminuição significativa (p<0,05) da amplitude do sinal (em relação a dados normativos) em um mínimo de 30 setores do campo visual, resultado que não foi observado no grupo controle. Nos testes de visão de cores, foi encontrada uma correlação (Spearman) positiva e significativa entre o tempo de trabalho e os índices do Lanthony D15d (p=0,52; p<0,05) e os limiares no eixo deutan (p=0,59; p<0,05). Na campimetria, houve correlações negativas significativas com o tempo de trabalho para a área da Fóvea (p=-051; p<0,05), e para os anéis de 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). Não foi encontrada correlação significativa entre a sensibilidade ao contraste e o tempo de trabalho. Conclusões: Os resultados mostram alterações amplas e difusas no processamento visual em decorrência da exposição crônica a solventes orgânicos / Purpose: To evaluate the outcome of chronic occupational exposure to a mixture of solvents on the visual system of a group of gas station workers. Methods: 25 gas station workers (20 male; M=36,4 years old, SD=8,9) and 25 controls (10 male; M=33,8 years old, DP=8,8) with no history of chronic exposure to solvents were tested for hue discrimination and arrangement, spatial contrast sensitivity, visual field and multifocal VEPs. Urinary concentrations of toluene (M=0,3g/g of creatinine; Sd=0,16) and xylene metabolites (M=0,1 g/g creatinine; SD=0), along with the time of work (M=9,6 years; SD=6,2) were used as indicators of the exposure. The participants were submitted to an ophthalmologic examination and corrected the visual acuity to 20/20 whenever needed. All measurements were monocular (eye randomly chosen) and only one eye was tested, except for Multifocal Visual Evoked Potential (mfVEP) and the automated perimetry. Color was evaluated with the Lanthony D15d and Cambridge Colour Test 2.0. Automatic static perimetry used the white-on-white 24-2 protocol of the Humphrey Field Analyzer II-750i. Visual field was also evaluated with the mfVEP system Veris Science 5.2.4. Contrast sensitivity was measured with Metropsis software, using sine wave gratings of 0,2; 0,5; 1,0; 2,0; 5,0; 10,0 and 20,0 cpd. Results: The results for the two groups were compared using the Mann-Whitney U test. In the color discrimination test, the groups were significantly different for the thresholds in the three confusion axis tested (p<0,05), area of the ellipse (p<0,01) and ellipticity (p<0,05). In the color arrangement test, the two groups were significantly different (p<0,01). The automated perimetry results were also significantly different between groups for the 90, 150 e 210 eccentricity rings (p<0,05) and the MD and PSD values (p<0,05). Only three of the workers were tested with the mfVEP so far. All three had at least 30 sectors in the visual field 10 with significant loss of amplitude in the response (p<0,05, when compared to normative data). This result was not observed in the control group. The Spearman correlation coefficient was used to look for significant correlations between time of work and visual performance. For color vision, we found significant positive correlation between time of work and indexes of the Lanthony D15d (p=0,52; p<0,05) and deutan axis thresholds (p=0,59; p<0,05) for the CCT test. The analysis of sensitivity in eccentricity rings of perimetry data showed significant negative correlation with the time of work for the Fovea (p=-051; p<0,05) and rings of 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). The contrast sensitivity data was not significantly correlated with time of work. Conclusions: The results presented here suggest that chronic occupational exposure to organic solvents leads to changes in the visual system function even when the exposure is within occupational safety limits. The results also suggest that the visual changes are extensive and diffuse
13

Repercussões visuais da exposição ocupacional a uma mistura de solventes orgânicos: visão cromática e acromática em frentistas brasileiros / Visual repercussions of occupational exposure to a mixture of solvents: Chromatic and achromatic vision in brazilian gas station workers

Thiago Leiros Costa 13 December 2010 (has links)
Objetivo: Avaliar repercussões da exposição ocupacional a uma mistura de solventes orgânicos sobre o desempenho visual de um grupo de frentistas. Método: Foram aplicados testes de ordenamento e discriminação de matizes, campo visual e sensibilidade ao contraste espacial de luminância em 25 frentistas (20 homens, M=36,4 anos, DP=8,9) e 25 controles sem histórico de exposição crônica a solventes (10 homens, M=33,8 anos, DP=8,8). As concentrações metabólitos urinários de tolueno (M=0,3 g/g de creatinina; DP=0,16) e xileno (M=0,1 g/g de creatinina; DP=0,02) e o tempo de trabalho (M=9,6 anos; DP=6,2) foram utilizados como indicativos da exposição dos frentistas. Os participantes foram submetidos a exame oftalmológico, e quando necessário, corrigir a acuidade visual para 20/20. Todas as medidas foram realizadas monocularmente com um olho escolhido ao acaso, com exceção do Potencial Visual Evocado Multifocal (PVEmf) e da campimetria. Para avaliar a visão de cores, utilizamos o Lanthony D15-d e Cambridge Colour Test 2.0. Na campimetria estática automatizada foi utilizado o protocolo branco-branco 24-2 do aparelho Humphrey Field Analyzer II-750i. A atividade elétrica visual cortical foi avaliada com o sistema de PVEmf Veris Science 5.2.4, utilizando um estímulo de 60 setores. A sensibilidade ao contraste espacial de luminância foi avaliada no teste Metropsis, para grades senoidais em 7 frequências espaciais de 0,2 a 20,0 cpg. Resultados: Os escores do grupo de frentistas e do grupo controle foram comparados pelo teste Mann-Whitney U. No teste de discriminação de cores (CCT), houve diferença estatística significativa entre controles e frentistas para a área total da elipse (p<0,01), elipticidade (p<0,05) e limiares nos eixos protan, deutan e tritan (p<0,05). No D15d houve diferença significativa entre os 8 dois grupos (p<0,01). Os dados da campimetria apresentaram diferenças significativas entre os dois grupos para as excentricidades de 90, 150 e 210, além dos valores de MD e PSD (p<0,05). Dos três frentistas avaliados com o PVEmf, todos apresentaram uma diminuição significativa (p<0,05) da amplitude do sinal (em relação a dados normativos) em um mínimo de 30 setores do campo visual, resultado que não foi observado no grupo controle. Nos testes de visão de cores, foi encontrada uma correlação (Spearman) positiva e significativa entre o tempo de trabalho e os índices do Lanthony D15d (p=0,52; p<0,05) e os limiares no eixo deutan (p=0,59; p<0,05). Na campimetria, houve correlações negativas significativas com o tempo de trabalho para a área da Fóvea (p=-051; p<0,05), e para os anéis de 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). Não foi encontrada correlação significativa entre a sensibilidade ao contraste e o tempo de trabalho. Conclusões: Os resultados mostram alterações amplas e difusas no processamento visual em decorrência da exposição crônica a solventes orgânicos / Purpose: To evaluate the outcome of chronic occupational exposure to a mixture of solvents on the visual system of a group of gas station workers. Methods: 25 gas station workers (20 male; M=36,4 years old, SD=8,9) and 25 controls (10 male; M=33,8 years old, DP=8,8) with no history of chronic exposure to solvents were tested for hue discrimination and arrangement, spatial contrast sensitivity, visual field and multifocal VEPs. Urinary concentrations of toluene (M=0,3g/g of creatinine; Sd=0,16) and xylene metabolites (M=0,1 g/g creatinine; SD=0), along with the time of work (M=9,6 years; SD=6,2) were used as indicators of the exposure. The participants were submitted to an ophthalmologic examination and corrected the visual acuity to 20/20 whenever needed. All measurements were monocular (eye randomly chosen) and only one eye was tested, except for Multifocal Visual Evoked Potential (mfVEP) and the automated perimetry. Color was evaluated with the Lanthony D15d and Cambridge Colour Test 2.0. Automatic static perimetry used the white-on-white 24-2 protocol of the Humphrey Field Analyzer II-750i. Visual field was also evaluated with the mfVEP system Veris Science 5.2.4. Contrast sensitivity was measured with Metropsis software, using sine wave gratings of 0,2; 0,5; 1,0; 2,0; 5,0; 10,0 and 20,0 cpd. Results: The results for the two groups were compared using the Mann-Whitney U test. In the color discrimination test, the groups were significantly different for the thresholds in the three confusion axis tested (p<0,05), area of the ellipse (p<0,01) and ellipticity (p<0,05). In the color arrangement test, the two groups were significantly different (p<0,01). The automated perimetry results were also significantly different between groups for the 90, 150 e 210 eccentricity rings (p<0,05) and the MD and PSD values (p<0,05). Only three of the workers were tested with the mfVEP so far. All three had at least 30 sectors in the visual field 10 with significant loss of amplitude in the response (p<0,05, when compared to normative data). This result was not observed in the control group. The Spearman correlation coefficient was used to look for significant correlations between time of work and visual performance. For color vision, we found significant positive correlation between time of work and indexes of the Lanthony D15d (p=0,52; p<0,05) and deutan axis thresholds (p=0,59; p<0,05) for the CCT test. The analysis of sensitivity in eccentricity rings of perimetry data showed significant negative correlation with the time of work for the Fovea (p=-051; p<0,05) and rings of 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). The contrast sensitivity data was not significantly correlated with time of work. Conclusions: The results presented here suggest that chronic occupational exposure to organic solvents leads to changes in the visual system function even when the exposure is within occupational safety limits. The results also suggest that the visual changes are extensive and diffuse
14

O efeito do exercício físico sobre a visão de indivíduos com diabetes mellitus tipo 1: avaliação psicofísica e eletrofisiológica / The effect of physical exercise on the vision of type 1 diabetes patients: psychophysical and electrophysiological evaluation

Valéria Duarte Garcia 18 November 2016 (has links)
O presente estudo investigou a função visual de pacientes com diabetes tipo 1 atletas e sedentários através de testes psicofísicos e eletrofisiológicos computadorizados de última geração. O objetivo foi investigar possíveis efeitos do exercício físico nas funções visuais. Materiais e Métodos: 33 pacientes com diabetes tipo 1, divididos em dois grupos experimentais: diabético atleta (n = 15; idade = 33,33 ± 6,78; tempo de doença =16,19 ± 6,63) e diabéticos sedentário (n = 18 idade = 28,94 ± 6,04; tempo de doença = 15,92 ± 8,46) e 40 sujeitos controles: controle atleta (n = 20; idade = 32,0 ± 5,61) e controle sedentário ( n = 20; idade = 27,05 5,60 ) foram submetidos a exames de: visão de cores e sensibilidade ao contraste Cambridge Colour Test - CCT; eletroretinograma por padrão reverso PERG e análises laboratoriais para quantificar óxido nítrico e endotelina por quimioluminescência e ELISA. As comparações entre os grupos foram feitas através de teste não paramétrico (Teste Kruskal-Wallis). Resultados: O grupo Diabético apresentou perdas significativas na amplitude do PERG, na discriminação de cores no eixo protan, área da elipse e nas frequências espaciais avaliadas da função da sensibilidade ao contraste, além de disfunção dos fatores endoteliais comparado ao grupo Controle. O grupo diabético atleta apresentou concentração maior de óxido nítrico comparado ao grupo Diabético sedentário. Não foram encontradas correlações entre os fatores endoteliais e as funções visuais. Conclusão: foram encontradas perdas funcionais na avaliação psicofísica e eletrofisiológica de pacientes com diabetes tipo 1. Os achados deste estudo confirmam a hipótese de que as perdas visuais sejam de origem neural pós - receptoral. Aumento na concentração de óxido nítrico encontrado em pacientes diabéticos atletas, confirmam os achados da literatura de que o exercício físico é capaz de aumentar a biodisponibilidade deste fator endotelial. Entretanto esse aumento de biodisponibilidade não se refletiu em recuperação das perdas nas funções visuais, uma vez que não houve correlação entre as alterações dos fatores endoteliais e os resultados da avaliação visual. A conclusão, em resumo, é de que o exercício físico não promoveu proteção dos danos visuais verificados em pacientes diabéticos / The study compared visual functions of sedentary and athlete patients with type 1 diabetes, and respective controls, using computerized psychophysical and electrophysiological tests. Materials and Methods: 33 Patients with type 1 diabetes, divided into two experimental groups: athlete diabetics (n = 15; age = 33.33 ± 6.78; rate of disease = 16.19 ± 6.63) and sedentary diabetics ( n = 18 age = 28.94 ± 6.04; rate of disease = 15.92 ± 8.46) and 40 control subjects: athlete control (n = 20; age = 32.0 ± 5.61) and sedentary control (n = 20; age = 27.05 5.60) were subjected to tests of: color vision and contrast sensitivity - Cambridge Colour Test - CCT; pattern electroretinogram (PERG) and laboratorial analysis of nitric oxide and endothelin using chemiluminescence and ELISA. The comparisons between groups were made through the nonparametric (Kruskal-Wallis test). Results: compared the control group, the diabetic group showed significant losses (1) in color discrimination in the protan axis and in ellipse area (2) in several spatial frequencies of the luminance spatial contrast sensitivity function; (3) a reduction in PERG amplitude and (4) dysfunction of endothelial factors. The athlete diabetic group showed increased concentration of nitric oxide compared to the sedentary diabetic group. No correlations were found between the endothelial factors and visual functions. Conclusion: losses in psychophysical and electrophysiological functions were found in patients with type 1 diabetes. The findings support the hypothesis that visual losses are due to the post-receptoral pathways. Increased nitric oxide concentration found in athlete diabetic patients, confirm the findings of the literature that physical exercise can increase the bioavailability this endothelial factor. However this increase in bioavailability was not reflected in the recovery of losses in visual functions, since there was no correlation between changes in endothelial factors and results of visual assessment. In conclusion, the exercise did not promote protection against visual losses due to diabetes
15

Estudo comparativo entre a ceratectomia fotorrefrativa e a ceratomileusis in situ a laser guiadas pela análise de frente de onda / Comparative study between wavefront-guided photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK)

Barreto Júnior, Jackson 11 June 2010 (has links)
OBJETIVO: Comparar os resultados de duas técnicas cirúrgicas guiadas pela análise de frente de onda, a ceratectomia fotorrefrativa (PRK) e a ceratomileusis in situ a laser (LASIK), para correção da miopia baixa a moderada, associada ou não ao astigmatismo. LOCAL: Setor de Cirurgia Refrativa da Clínica Oftalmológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brasil. MÉTODOS: Estudo prospectivo randomizado envolvendo 70 olhos (35 pacientes) submetidos ao LASIK personalizado em um olho e PRK personalizado no olho contralateral para correção de miopia até 5 dioptrias (D) e astigmatismo até 1,5D. Avaliou-se acuidade visual não-corrigida (AVNC), melhor acuidade visual corrigida (MAVC), resultados refratométricos, aberrometria, sensibilidade ao contraste fotópico e mesópico, acuidade visual de baixo contraste (AVBC), qualidade da imagem retiniana (Função de Transferência Modular e Strehl ratio) e espalhamento intraocular de luz (EIL) no período pré-operatório e no 1o, 3o, 6o e 12o mês pós-operatório. RESULTADOS: O equivalente esférico (EE) médio pré-operatório foi -2,57 ± 0,95D no grupo LASIK e, no grupo PRK, -2,52 ± 0,90D (p = 0,722). No 12o mês pósoperatório (PO), EE foi -0,06 ± 0,33D e -0,12 ± 0,41D, respectivamente (p = 0,438). No grupo LASIK, 60,0% dos olhos apresentaram AVNC 20/16 e 96,7% 20/20, e no grupo PRK, 66,6% e 96,7%, respectivamente (p = 0,667). No período pré-operatório, o total das aberrações de alta ordem (HOAs) foi 0,37 ± 0,09 m no grupo LASIK e 0,36 ± 0,11m no grupo PRK (p = 0,752). No 12o mês PO, o total das HOAs foi 0,46 ± 0,21m no grupo LASIK e 0,42 ± 0,14m no grupo PRK (p = 0,438). Tanto o teste de sensibilidade ao contraste fotópico como o mesópico apresentaram resultados semelhantes entre as técnicas, exceto pela freqüência 1,5 ciclos por grau (cpg) do teste mesópico no 12o mês PO, a favor do grupo PRK. Os índices de qualidade da imagem retiniana mostraram comportamento similar entre as técnicas ao longo do seguimento. Não houve aumento significativo do espalhamento intraocular da luz em ambos os grupos, quatro olhos cursaram com aumento transitório. CONCLUSÃO: Dentro das condições deste estudo, ambas as técnicas apresentaram excelentes resultados refratométricos e função visual semelhante. Apesar do tratamento personalizado guiado pela análise de frentes de onda, houve indução das HOAs, de forma similar, tanto no LASIK como no PRK. / PURPOSE: To compare clinical results of two wavefront-guided treatments, photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK), for low to moderate myopia correction, with or without astigmatism. SETTING: Refractive Surgery Service, General Hospital, University Of São Paulo, São Paulo, Brazil. METHODS: Prospective randomized study of 70 eyes (35 patients) submitted to custom LASIK and custom PRK (contralateral eye) for myopia up to 5D and astigmatism up to 1,5D. Uncorrected visual acuity (AVNC), best-corrected visual acuity (MAVC), refractive results, wavefront analysis, photopic and mesopic contrast sensitivity, low contrast visual acuity (AVBC), retinal image quality (Modulation Transfer Function and Strehl ratio) and intraocular straylight (EIL) were performed preoperatively and at one, three, six and twelve months postoperatively. RESULTS: The mean preoperative spherical equivalent (EE) was -2,57 ± 0,95D in the LASIK group and -2,52 ± 0,90D in the PRK group (p = 0,722). At twelve months postoperatively (PO), the mean EE was -0,06 ± 0,33D and -0,12 ± 0,41D, respectively (p = 0,438). In the LASIK group, 60,0% had AVNC 20/16 and 96,7% 20/20, and in the PRK group, 66,6% e 96,7%, respectively (p = 0,667). The mean pre-treatment total high-order aberrations (HOAs) was 0,37 ± 0,09 m in the LASIK group and 0,36 ± 0,11m in the PRK group (p = 0,752). At twelve months PO, the mean total HOAs was 0,46 ± 0,21m in the LASIK group and 0,42 ± 0,14 m in the PRK group (p = 0,438). No significant difference in photopic and mesopic contrast sensitivity between groups was noted, apart from the 1,5 cpg frequency of the mesopic test, favoring PRK, at the 12th month PO. Similar results were found for retinal image quality metrics during the follow-up. No significant increase of the intraocular straylight was found for both techniques, four eyes presented transitory elevations. CONCLUSION: In the conditions of this study, both techniques had excellent refractive results and similar visual function. In spite of the wavefront-guided treatments, HOAs were induced similarly after LASIK and PRK
16

Avaliações psicofísicas cromática e acromática de homens e mulheres expostos a solventes orgânicos

Oliveira, Ana Raquel de 24 February 2015 (has links)
Submitted by Maria Suzana Diniz (msuzanad@hotmail.com) on 2015-10-14T14:54:42Z No. of bitstreams: 1 arquivototal.pdf: 2900404 bytes, checksum: 1ee5854e28bd882478910deb4dcb5943 (MD5) / Made available in DSpace on 2015-10-14T14:54:42Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2900404 bytes, checksum: 1ee5854e28bd882478910deb4dcb5943 (MD5) Previous issue date: 2015-02-24 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Workers chronically exposed to a variety of organic solvents may suffer from changes in color vision and contrast sensitivity (CS). However, few studies have investigated whether there are sex-related differences in these changes, one of the factors that can change the toxicokinetics of solvents. Hence, the aim of this study was to determine whether there would be differences between women and men exposed in terms of their chromatic and achromatic visual psychophysical responses. A total of 44 individuals, Control Group total (CGt; n = 22) and Study Group total (SGt; n = 22) participated in the experiment, subdivided into the following groups: Study Group men (SGm): 11 men exposed to solvents (Age, M = 30.18, SD = 6.48; Education level, M = 9.73, SD = 2.10; Work duration, M = 6.53, SD = 4.38); Study Group women (SGw): 11 women exposed to solvents (Age, M = 26.91, SD = 5.86; Education level, M = 10, 36, SD = 0.92; Work duration, M = 4.70, SD = 3.53); Control Group men (CGm): 11 unexposed men (Age, M = 26.73, SD = 6.5; Education level, M = 9.73; SD = 1.8); Control Group women (CGm): 11 unexposed women (Age, M = 26.55, SD = 6.5; Education level, M = 10.45; SD = 1.51). The project was approved by the Ethics Committee of the Health Sciences Center (SCC) at the Federal University of Paraíba (UFPB), with CAAE registry number 21350113.9.0000.5188. Initially the participants underwent a screening step, with the following inclusion criteria, among others: a 20/20 or corrected visual acuity (evaluated via optotypes and Rasquin testing) and no dyschromatopsia (evaluated using Ishirara Test). Assessment of color perception was performed using the D15 desaturated Lanthony test (D15d) and the Cambridge Colour Test (CCT). The evaluation was performed by CS stimulation using sinusoidal gratings with a vertical spatial frequency of 0.2, 0.5, 1.0, 2.0, 5.0, 10, and 16 cycles per degree (cpd) of visual angle. Furthermore, an assessment of body composition from an examination of bioimpedance. The data were analyzed using the SPSS software package, version 21. First, the overall results between the SGt group (n = 22) and CGt group (n = 22) were compared, and were subsequently compared by sex (n = 11). The results showed that the study group (SGt) (Mdn = 1.18; M = 1.31, SD = 0.32) had a significantly higher ICC (U = 128, p = 0.01) than the CGt (Mdn = 1.09; M = 1.10, SD = 0.26), while there were no significant differences between solvent-exposed men and women (U = 51.0, p = 0.53). In CCT testing (Trivector Protocol), the SGt had a length corresponding to the vector protan axis (Mdn = 50.00; M = 54.00, SD = 16.42), and was significantly higher (U = 133.50, p = 0, 01) than the combined CGt group (Mdn = 40.00; M = 42.59, SD = 16.42), while according to the ellipse protocol, the SGt (Mdn = 981.15; M = 8086.81 ; SD = 22787.81) had a significantly higher ellipse area in A3 (U = 158.00, p = 0.04) compared to the CGt (Mdn = 657.30; M = 781.75, SD = 528.68), but men and women showed no significant differences in both CCT protocols (p > 0,05). The results of the CS showed that the SGt had lower CS in the following frequencies: 0.2 (U = 116,500, p = 0.003); 0.5 (U = 117.00, p = 0.003); 5.0 (U = 149.50, p = 0.03) and 10 cpd (U = 150.00, p = 0.03) compared to the CGt. The SGm (U = 25.0, p = 0.02) had significantly higher CS than SGm at the 0.5 cpd frequency value. The correlational analyses showed that among SGw, the diameter values of circles equivalent to the A1 and A2 ellipse areas retained a significant correlation with MCM: ρ = -0.68; p = 0.02 and ρ = -0.83; p = 0.01, respectively. Among SGw, the diameter value of the circle equivalent to the A2 area was negatively correlated with fat mass: ρ = -0.67; p = 0.02, in other words a greater amount of fatty tissue was correlated with a lower error trend in the red-green opponency axis, in addition, the diameter value of the circle equivalent to the A3 area had a positive correlation with MCM: ρ = 0.61; p = 0.04, i.e. a greater amount of MCM was correlated with a greater tendency to error in the color opponency axis. In short, the data on color vision and the SC obtained by solvent-exposed women and men found no strong evidence of possible differences between the sexes. However, the associations of psychophysiological measurements with the body measurements seem to indicate that fat can act as a protective factor of the organism against the effects of solvents, since fatty tissues may retain a proportion of solvents. In this regard, women could be less affected by solvents by having, on average, a larger proportion of adipose tissue than men. / Trabalhadores expostos de forma crônica à mistura de solventes orgânicos podem sofrer alterações na visão de cores e na sensibilidade ao contraste (SC). Entretanto, poucos estudos investigaram se há diferenças entre os sexos, um dos fatores que podem alterar a toxicocinética dos solventes. Diante disto, o objetivo do presente estudo foi verificar se haveria diferença entre mulheres e homens expostos quanto as respostas psicofísicas visuais cromáticas e acromáticas. Participaram 44 pessoas, Grupo de Estudo total (GEt; n = 22) e Grupo Controle total (GCt; n = 22) que formaram os seguintes grupos: Grupo de Estudo Homens (GEh): 11 homens expostos (Idade M = 30,18; DP = 6,48; Escolaridade M = 9,73; DP = 2,10; Tempo de serviço M = 6,53; DP = 4,38); Grupo de Estudo Mulheres (GEh): 11 mulheres expostas (Idade M = 26,91; DP = 5,86; Escolaridade M = 10, 36; DP = 0,92; Tempo de serviço M = 4,70; DP = 3,53); Grupo Controle Homens (GCh): 11 homens não expostos (Idade M = 26,73; DP = 6,5; Escolaridade M = 9,73; DP = 1,8); Grupo Controle Mulheres (GCm): 11 mulheres não expostas (Idade M = 26,55; DP = 6,5; Escolaridade M = 10,45; DP = 1,51). O projeto foi aprovado pelo Comitê de Ética do Centro de Ciências da Saúde (CCS) da Universidade Federal da Paraíba (UFPB), com número de CAAE: 21350113.9.0000.5188. Inicialmente os participantes realizaram uma de triagem, permanecendo aqueles que, entre outros critérios, apresentaram acuidade visual 20/20 ou corrigida (Optotipos E de Rasquin) e ausência de discromatopsias congênitas (Teste de Ishirara). A avaliação da percepção cromática foi realizada por meio dos testes D15 Dessaturado de Lanthony (D15d) e Cambridge Colour Test (CCT). A avaliação da SC foi realizada com estímulos de grades senoidais verticais de frequências espaciais de 0,2; 0,5; 1,0; 2,0; 5,0; 10 e 16 cpg de ângulo visual. Ainda foi realizada uma avaliação da composição corporal a partir de um exame de biompedância. Os dados foram analisados por meio do software SPSS, versão 21. Primeiramente, foram comparados os resultados entre o GEt (n = 22) e o GCt (n = 22), em seguida os resultados foram comparados por sexo (n = 11). Os resultados mostraram que o GEt apresentou ICC (Mdn = 1,18; M = 1,31; DP = 0,32) significativamente maior (U = 128; p = 0,01) ao GC (Mdn = 1,09; M = 1,10; DP = 0,26), ao passo que entre mulheres e homens expostos não houve diferenças (U = 51,0; p = 0,53). Com relação ao CCT, Protocolo Trivector, o GEt apresentou comprimento correspondente ao vetor do eixo protan (Mdn = 50,00; M = 54,00; DP = 16,42) significativamente maior (U = 133,50; p = 0,01) que o GC (Mdn = 40,00; M = 42,59; DP = 16,42), já no Protocolo Elipse, o GEt obteve área da elipse A3 (Mdn = 981,15; M = 8086,81; DP = 22787,81) significativamente maior (U = 158,00; p = 0,04) em relação ao GCt (Mdn = 657,30; M = 781,75; DP = 528,68), mas homens e mulheres não apresentaram diferenças em ambos os protocolos do CCT (p > 0,05).. Os resultados da SC mostraram que o GEt apresentou SC menor nas frequências: 0,2 (U = 116,50; p = 0,003); 0,5 (U = 117,00; p = 0,003); 5,0 (U = 149,50; p = 0,03) e 10 cpg (U = 150,00; p = 0,03) comparado ao GCt. O GEm obtive SC significativamente maior (U = 26,0; p 0,02) que o GEh na frequência 0,5 cpg. As análises correlacionais evidenciaram que entre o GEh, os valores dos diâmetros dos círculos equivalentes as áreas das elipses A1 e A2 mantiveram correlação com a MCM: = -0,68; p = 0,02 e = -0,83; p = 0,01, respectivamente. Já entre o GEm o valor do diâmetro do círculo equivalente a área A2 apresentou correlação negativa com a massa de gordura: = -0,67; p = 0,02, ou seja quanto mais gordura, menor tendência de erro no eixo de oponência de cor vermelho-verde, e ainda o valor do diâmetro do círculo equivalente a área A3 obteve correlação positiva com a MCM: = 0,61; p = 0,04, isto é quanto maior a quantidade de MCM, maior tendência de erro no eixo de oponência de cor. Em suma, os dados relativos à visão de cores e a SC obtidos por mulheres e homens expostos não encontraram fortes evidências de possíveis diferenças entre os sexos. Entretanto, as associações das medidas psicofísicas com as medidas corporais parecem indicar que a gordura pode atuar como um fator de proteção do organismo contra os efeitos dos solventes, já que tecidos gordurosos podem reter produto. Nesta perspectiva, as mulheres poderiam ser menos afetadas por apresentarem quantidade maior de tecido adiposo.
17

Avaliação da acuidade visual e qualidade de vida pós-operatórias de pacientes submetidos ao implante bilateral da lente intraocular multifocal refrativa-difrativa EyeDiff / Evaluation of patients' visual acuity and quality of life after bilateral implantation of multifocal intraocular lens EyeDiff

Queiroz, Marjorie Fornazier do Nascimento de 22 February 2018 (has links)
Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-13T13:33:12Z No. of bitstreams: 1 Dissertação corrigida.docx: 1063474 bytes, checksum: a294630584043d85364c1994f91ac26e (MD5) / Rejected by Luciana Pizzani null (luciana@btu.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: problema 1: o arquivo submetido deve, obrigatoriamente, estar em formato PDF. Seu arquivo está em word. Assim que tiver efetuado essa correção submeta o arquivo, em PDF, novamente. Agradecemos a compreensão. on 2018-04-13T17:52:53Z (GMT) / Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-13T20:18:43Z No. of bitstreams: 2 Dissertação corrigida.pdf: 3450020 bytes, checksum: c8bca522995d10e2ee7b7d957bd1b67c (MD5) Ficha catalográfica.pdf: 196557 bytes, checksum: 0a1da60dbc50589c50298c259a920c52 (MD5) / Rejected by ROSANGELA APARECIDA LOBO null (rosangelalobo@btu.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: problema 1: arquivos separados (dissertação e ficha catalográfica) O arquivo deve ser único e a ficha catalográfica deve ser inserida no arquivo PDF logo após a folha de rosto do seu trabalho. Assim que tiver efetuado a correção ou correções submeta o arquivo em PDF novamente. Agradecemos a compreensão. on 2018-04-17T13:29:17Z (GMT) / Submitted by Marjorie Fornazier do Nascimento de Queiroz (marjorienascimento@hotmail.com) on 2018-04-17T19:51:20Z No. of bitstreams: 1 Dissertação corrigida c ficha cat (1).pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) / Approved for entry into archive by Luciana Pizzani null (luciana@btu.unesp.br) on 2018-04-19T12:13:23Z (GMT) No. of bitstreams: 1 queiroz_mfn_me_bot.pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) / Made available in DSpace on 2018-04-19T12:13:23Z (GMT). No. of bitstreams: 1 queiroz_mfn_me_bot.pdf: 2835298 bytes, checksum: ec7c94dadce775ba947336b5608bc560 (MD5) Previous issue date: 2018-02-22 / RESUMO Objetivo: o presente estudo teve como objetivo geral avaliar os resultados visuais, satisfação e qualidade de vida de pacientes submetidos a implante bilateral de LIO multifocal e como objetivos específicos, a avaliação da acuidade visual (AV) para longe, perto e intermediária, do teste de sensibilidade ao contraste e da qualidade de vida destes pacientes por meio de questionário (NEI-VFQ 25). Métodos: foi realizado um estudo prospectivo e intervencionista que incluiu 20 pacientes portadores de catarata senil bilateral, em acompanhamento no setor de Catarata dos Hospital das Clínicas da Faculdade de Medicina de Botucatu. Os critérios de exclusão foram astigmatismo corneano maior que 1,5 D, olho único, história de cirurgia intraocular prévia ou doença ocular que cause redução da AV, falta de motivação do paciente em realizar o procedimento cirúrgico bilateralmente, complicações intra-operatórias e recusa em assinar o TCLE. Os pacientes foram submetidos a implante bilateral da LIO multifocal EyeDiff®, da Eyeol UK®, e foram avaliados no 1o, 3o e 6o mês de pós-operatório com medidas da AV (longe, intermediária e perto, monocular e binocular, sob condições fotópicas e mesópicas), qualidade de visão (avaliação da sensibilidade ao contraste) e qualidade de vida através de um questionário de satisfação. Resultados: todos os olhos apresentaram AV monocular e binocular de 0,3 LogMAR ou melhor para longe e J3 ou melhor para perto com a melhor correção para longe, sob condições fotópicas. A curva de defocus mostrou adição de +2,50 no plano dos óculos. A sensibilidade ao contrate esteve no nível inferior da normalidade para frequências espaciais baixas e altas e abaixo do nível mínimo em frequências intermediárias. A media geral das avaliações no questionário de qualidade de vida foi de 91. Conclusão: conclui-se que o implante da LIO multifocal proporcionou bons resultados no que se refere à AV pós-operatória, além de maior independência dos óculos e melhora da qualidade de vida. / ABSTRACT Purpose: the present study had as main goal to evaluate visual outcomes, satisfaction and quality of life of patients submitted to bilateral implant of multifocal intraocular lens (IOL), and as specific aims, evaluation of distance, intermediate and near visual acuity (VA), contrast sensitivity and quality of life of these patients using a questionnaire (NEI-VFQ 25). Methods: this was a prospective and interventionist study, that included 20 patients with bilateral senil cataract, followed at Botucatu Medicine School. Exclusion criteria were corneal astigmatism superior to 1,50 D, single eye, previous intraocular surgery or ocular disease, intra-operatory complications and refuse in signing the consent form. Patients were submitted to bilateral implant of multifocal IOL EyeDiff® Eyeol UK® and were evaluated at 1o, 3o and 6o month, postoperatively, with VA testing (for distance, intermediate and near, monocular and binocular, under fotopic and mesopic conditions), eyesight quality (contrast sensitivity evaluation) and quality of life through a satisfaction questionnaire. Results: all eyes presented monocular and binocular CDVA of 0,3 LogMar or better and DCNVA of J3 or better, under photopic and mesopic conditions. Defocus curve showed best performance at +2,50 D. Contrast sensitivity were in the minimum level of normality for low and high special frequencies and under normal limits for intermediate special frequency. The quality of life questionnaire had average score of 91. Conclusion: in conclusion, multifocal IOL implant provided good results for post-operative VA, in addition to greater spectacle independence and quality of life improvement.
18

Avaliação da acuidade visual e qualidade de vida pós-operatórias de pacientes submetidos ao implante bilateral da lente intraocular multifocal refrativa-difrativa EyeDiff

Queiroz, Marjorie Fornazier do Nascimento de January 2018 (has links)
Orientador: Antonio Carlos Lottelli Rodrigues / Resumo: RESUMO Objetivo: o presente estudo teve como objetivo geral avaliar os resultados visuais, satisfação e qualidade de vida de pacientes submetidos a implante bilateral de LIO multifocal e como objetivos específicos, a avaliação da acuidade visual (AV) para longe, perto e intermediária, do teste de sensibilidade ao contraste e da qualidade de vida destes pacientes por meio de questionário (NEI-VFQ 25). Métodos: foi realizado um estudo prospectivo e intervencionista que incluiu 20 pacientes portadores de catarata senil bilateral, em acompanhamento no setor de Catarata dos Hospital das Clínicas da Faculdade de Medicina de Botucatu. Os critérios de exclusão foram astigmatismo corneano maior que 1,5 D, olho único, história de cirurgia intraocular prévia ou doença ocular que cause redução da AV, falta de motivação do paciente em realizar o procedimento cirúrgico bilateralmente, complicações intra-operatórias e recusa em assinar o TCLE. Os pacientes foram submetidos a implante bilateral da LIO multifocal EyeDiff®, da Eyeol UK®, e foram avaliados no 1o, 3o e 6o mês de pós-operatório com medidas da AV (longe, intermediária e perto, monocular e binocular, sob condições fotópicas e mesópicas), qualidade de visão (avaliação da sensibilidade ao contraste) e qualidade de vida através de um questionário de satisfação. Resultados: todos os olhos apresentaram AV monocular e binocular de 0,3 LogMAR ou melhor para longe e J3 ou melhor para perto com a melhor correção para longe, sob condições fo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: ABSTRACT Purpose: the present study had as main goal to evaluate visual outcomes, satisfaction and quality of life of patients submitted to bilateral implant of multifocal intraocular lens (IOL), and as specific aims, evaluation of distance, intermediate and near visual acuity (VA), contrast sensitivity and quality of life of these patients using a questionnaire (NEI-VFQ 25). Methods: this was a prospective and interventionist study, that included 20 patients with bilateral senil cataract, followed at Botucatu Medicine School. Exclusion criteria were corneal astigmatism superior to 1,50 D, single eye, previous intraocular surgery or ocular disease, intra-operatory complications and refuse in signing the consent form. Patients were submitted to bilateral implant of multifocal IOL EyeDiff® Eyeol UK® and were evaluated at 1o, 3o and 6o month, postoperatively, with VA testing (for distance, intermediate and near, monocular and binocular, under fotopic and mesopic conditions), eyesight quality (contrast sensitivity evaluation) and quality of life through a satisfaction questionnaire. Results: all eyes presented monocular and binocular CDVA of 0,3 LogMar or better and DCNVA of J3 or better, under photopic and mesopic conditions. Defocus curve showed best performance at +2,50 D. Contrast sensitivity were in the minimum level of normality for low and high special frequencies and under normal limits for intermediate special frequency. The quality of life questionnaire had average scor... (Complete abstract click electronic access below) / Mestre
19

Percepção de contraste e perdas neurais na esclerose múltipla / Contrast perception and neural losses in multiple sclerosis

Ana Laura de Araujo Moura 08 December 2010 (has links)
Objetivos: Avaliar a integridade das vias magnocelular (M) e parvocelular (P) atraves da percepcao de contraste e avaliar a sensibilidade no campo visual e respostas no ERG multifocal, em pacientes com esclerose multipla. Métodos e Resultados: Foram avaliados 29 pacientes (20F; 9M; idade media = 35,76 }10,91 anos) com diagnostico de esclerose multipla (15 com historico de neurite optica). Todos os pacientes apresentavam acuidade visual entre 0 e 0,1 logMAR. A percepcao de contraste foi avaliada atraves da funcao de sensibilidade ao contraste (programa PSYCHO; Cambridge Research System), com os limiares medidos em 0.2, 0.5, 1.0, 1.9, 5.3, 9.7 e 19.4 ciclos por grau; e do teste do Pedestal (Pokorny & Smith, 1997). O campo visual foi medido com o Campimetro Automatico de Humphrey, algoritmo SITA, estrategia central 24-2. O ERGmf foi registrado, utilizando o sistema VERIS, com 103 hexagonos. A analise foi baseada nos valores de amplitude e latencia de N1 e P1 das respostas de seis regioes predeterminadas de acordo com o mapa sugerido por Garway-Heath et al (2000), para os kernels de primeira e segunda ordem. Os pacientes foram divididos em 2 grupos: NO (antecedente de neurite optica) e SNO (sem antecedente de neurite optica). Resultados: O grupo NO nao diferiu do grupo SNO em nenhum dos testes, exceto nas medidas de amplitude do kernel de segunda ordem no ERGmf (Tukey HSD Test, PostHoc). Todos os pacientes mostraram uma reducao na percepcao de contraste, quando comparados ao grupo controle. Os resultados diferiram significativamente do grupo controle em todas as frequencias espaciais avaliadas na funcao de sensibilidade ao contraste (p < 0.001; ANOVA), e nos dois paradigmas avaliados pelo teste do Pedestal (p <0.05 ANOVA de medidas repetidas). As respostas do kernel de primeira ordem do ERGmf para ambos os grupos, quando comparados com o grupo controle, nao apresentaram diferenca estatistica significativa para as regioes analisadas (p > 0.05; ANOVA de medidas repetidas). As respostas de amplitude dos pacientes, para o kernel de segunda ordem apresentaram-se diferentes do grupo controle, com significancia estatistica para as areas 2, 3, 4, 5 e 6 (p < 0.05; ANOVA de medidas repetidas). Os resultados do campo visual mostraram reducao de sensibilidade nos pacientes em estudo, comparados ao grupo controle, com diferenca estatisticamente significante para todas as regioes (p <0.05; ANOVA de medidas repetidas). Conclusões: Aumento nos limiares de deteccao de contraste foram encontrados nos pacientes com esclerose multipla, em ambos os testes. O padrao de perda nas varias frequencias espaciais e em ambos os paradigmas analisados no teste do Pedestal, sugere um comprometimento nao seletivo das vias visuais, afetando tanto a via parvo como a magnocelular. As alteracoes nas respostas do ERG multifocal detectadas apenas no kernel de segunda ordem poderiam estar relacionadas a danos retrogrados a camada de fibras nervosas da retina causados pela desmielinizacao. Nao foram encontradas correlacoes com as perdas de sensibilidade no campo visual / Purpose: To assess the integrity of the magnocellular (M) and parvocellular (P) pathways by measuring contrast perception and to evaluate the visual field and multifocal ERG responses in patients with multiple sclerosis. Methods: 29 patients (20F, 9M, mean age = 35.76 } 10.91 years) diagnosed with multiple sclerosis were evaluated (15 with optic neuritis). All patients had visual acuity between 0 and 0.1 logMAR. The contrast perception was assessed by the measurement of contrast sensitivity function (program PSYCHO, Cambridge Research System) using spatial frequencies 0.2, 0.5, 1.0, 1.9, 5.3, 9.7 and 19.4 cycles per degree and the pedestal test (Pokorny & Smith, 1997). The visual field was measured using the central 24-2 SITA algorithm of the Humphrey Field Analyzer. The mfERG was recorded using the Veris system with 103 hexagons in which N1 and P1 amplitude and latency values of six predetermined areas according to the map suggested by Garway-Heath et al (2000) were used (first and second order kernels). Patients were divided into two groups: NO (with optic neuritis) and SNO (without optic neuritis). Results: The NO group did not differ from the SNO in any of the tests except for the second order kernel amplitudes in the mfERG (Tukey HSD posthoc test). All patients showed a reduction in contrast perception compared to the control group. The patients results were significantly different from the control groups at all spatial frequencies tested (p <0.001, ANOVA), and for the two paradigms of the pedestal test (p <0.05, ANOVA). The first order kernel responses in the mfERG showed no significant difference for both patient groups when compared with the control group (p> 0.05, ANOVA). The second order kernel amplitudes were different between patients and controls, with statistical significance for areas 2, 3, 4, 5 and 6 (p <0.05, ANOVA). The visual field results showed sensitivity reductions in the patients compared to controls, which was statistically significant for all regions (p <0.05, ANOVA). Conclusions: Increased thresholds for contrast detection were found in patients with multiple sclerosis in both tests. The pattern of loss in the various spatial frequencies and in both test paradigms of the Pedestal suggests a non-selective impairment of the visual pathways affecting both the parvo and magnocellular pathways. Changes in multifocal ERG responses found only in the second order kernel may be related to retrograde damage of the nerve fiber layer of the retina caused by demyelization. No significant correlation with the visual field losses was found
20

Estudo comparativo entre a ceratectomia fotorrefrativa e a ceratomileusis in situ a laser guiadas pela análise de frente de onda / Comparative study between wavefront-guided photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK)

Jackson Barreto Júnior 11 June 2010 (has links)
OBJETIVO: Comparar os resultados de duas técnicas cirúrgicas guiadas pela análise de frente de onda, a ceratectomia fotorrefrativa (PRK) e a ceratomileusis in situ a laser (LASIK), para correção da miopia baixa a moderada, associada ou não ao astigmatismo. LOCAL: Setor de Cirurgia Refrativa da Clínica Oftalmológica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brasil. MÉTODOS: Estudo prospectivo randomizado envolvendo 70 olhos (35 pacientes) submetidos ao LASIK personalizado em um olho e PRK personalizado no olho contralateral para correção de miopia até 5 dioptrias (D) e astigmatismo até 1,5D. Avaliou-se acuidade visual não-corrigida (AVNC), melhor acuidade visual corrigida (MAVC), resultados refratométricos, aberrometria, sensibilidade ao contraste fotópico e mesópico, acuidade visual de baixo contraste (AVBC), qualidade da imagem retiniana (Função de Transferência Modular e Strehl ratio) e espalhamento intraocular de luz (EIL) no período pré-operatório e no 1o, 3o, 6o e 12o mês pós-operatório. RESULTADOS: O equivalente esférico (EE) médio pré-operatório foi -2,57 ± 0,95D no grupo LASIK e, no grupo PRK, -2,52 ± 0,90D (p = 0,722). No 12o mês pósoperatório (PO), EE foi -0,06 ± 0,33D e -0,12 ± 0,41D, respectivamente (p = 0,438). No grupo LASIK, 60,0% dos olhos apresentaram AVNC 20/16 e 96,7% 20/20, e no grupo PRK, 66,6% e 96,7%, respectivamente (p = 0,667). No período pré-operatório, o total das aberrações de alta ordem (HOAs) foi 0,37 ± 0,09 m no grupo LASIK e 0,36 ± 0,11m no grupo PRK (p = 0,752). No 12o mês PO, o total das HOAs foi 0,46 ± 0,21m no grupo LASIK e 0,42 ± 0,14m no grupo PRK (p = 0,438). Tanto o teste de sensibilidade ao contraste fotópico como o mesópico apresentaram resultados semelhantes entre as técnicas, exceto pela freqüência 1,5 ciclos por grau (cpg) do teste mesópico no 12o mês PO, a favor do grupo PRK. Os índices de qualidade da imagem retiniana mostraram comportamento similar entre as técnicas ao longo do seguimento. Não houve aumento significativo do espalhamento intraocular da luz em ambos os grupos, quatro olhos cursaram com aumento transitório. CONCLUSÃO: Dentro das condições deste estudo, ambas as técnicas apresentaram excelentes resultados refratométricos e função visual semelhante. Apesar do tratamento personalizado guiado pela análise de frentes de onda, houve indução das HOAs, de forma similar, tanto no LASIK como no PRK. / PURPOSE: To compare clinical results of two wavefront-guided treatments, photorefractive keratectomy (PRK) and laser in situ keratomileusis (LASIK), for low to moderate myopia correction, with or without astigmatism. SETTING: Refractive Surgery Service, General Hospital, University Of São Paulo, São Paulo, Brazil. METHODS: Prospective randomized study of 70 eyes (35 patients) submitted to custom LASIK and custom PRK (contralateral eye) for myopia up to 5D and astigmatism up to 1,5D. Uncorrected visual acuity (AVNC), best-corrected visual acuity (MAVC), refractive results, wavefront analysis, photopic and mesopic contrast sensitivity, low contrast visual acuity (AVBC), retinal image quality (Modulation Transfer Function and Strehl ratio) and intraocular straylight (EIL) were performed preoperatively and at one, three, six and twelve months postoperatively. RESULTS: The mean preoperative spherical equivalent (EE) was -2,57 ± 0,95D in the LASIK group and -2,52 ± 0,90D in the PRK group (p = 0,722). At twelve months postoperatively (PO), the mean EE was -0,06 ± 0,33D and -0,12 ± 0,41D, respectively (p = 0,438). In the LASIK group, 60,0% had AVNC 20/16 and 96,7% 20/20, and in the PRK group, 66,6% e 96,7%, respectively (p = 0,667). The mean pre-treatment total high-order aberrations (HOAs) was 0,37 ± 0,09 m in the LASIK group and 0,36 ± 0,11m in the PRK group (p = 0,752). At twelve months PO, the mean total HOAs was 0,46 ± 0,21m in the LASIK group and 0,42 ± 0,14 m in the PRK group (p = 0,438). No significant difference in photopic and mesopic contrast sensitivity between groups was noted, apart from the 1,5 cpg frequency of the mesopic test, favoring PRK, at the 12th month PO. Similar results were found for retinal image quality metrics during the follow-up. No significant increase of the intraocular straylight was found for both techniques, four eyes presented transitory elevations. CONCLUSION: In the conditions of this study, both techniques had excellent refractive results and similar visual function. In spite of the wavefront-guided treatments, HOAs were induced similarly after LASIK and PRK

Page generated in 0.5631 seconds