• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 183
  • 53
  • 45
  • 39
  • 38
  • 37
  • 36
  • 34
  • 31
  • 24
  • 23
  • 22
  • 21
  • 20
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Developing a Laser Induced Liquid Beam Ion Desorption Spectral Database as Reference for Spaceborne Mass Spectrometers

Klenner, Fabian, Umair, Muhammad, Walter, Sebastian H. G., Khawaja, Nozair, Hillier, Jon, Nölle, Lenz, Zou, Zenghui, Napoleoni, Maryse, Sanderink, Arnaud, Zuschneid, Wilhelm, Abel, Bernd, Postberg, Frank 04 June 2024 (has links)
Spaceborne impact ionization mass spectrometers, such as the Cosmic Dust Analyzer on board the past Cassini spacecraft or the SUrface Dust Analyzer being built for NASA's upcoming Europa Clipper mission, are of crucial importance for the exploration of icy moons in the Solar System, such as Saturn's moon Enceladus or Jupiter's moon Europa. For the interpretation of data produced by these instruments, analogue experiments on Earth are essential. To date, thousands of laboratory mass spectra have been recorded with an analogue experiment for impact ionization mass spectrometers. Simulation of mass spectra of ice grains in space is achieved by a Laser Induced Liquid Beam Ion Desorption (LILBID) approach. The desorbed cations or anions are analyzed in a time-of-flight mass spectrometer. The amount of unstructured raw data is increasingly challenging to sort, process, interpret and compare with data from space. Thus far this has been achieved manually for individual mass spectra because no database containing the recorded reference spectra was available. Here we describe the development of a comprehensive, extendable database containing cation and anion mass spectra from the laboratory LILBID facility. The database is based on a Relational Database Management System with a web server interface and enables filtering of the laboratory data using a wide range of parameters. The mass spectra can be compared not only with data from past and future space missions but also mass spectral data generated by other, terrestrial, techniques. The validated and approved subset of the database is available for general public (https://lilbid-db.planet.fu-berlin.de).
142

Expressão de tireotrofina humana em células de embrião de rim humano (HEK293) / Human tryrotropin expression in human embrionic kidney cells (HEK293)

SANTANA, PATRICIA M. 22 December 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-12-22T16:39:39Z No. of bitstreams: 0 / Made available in DSpace on 2016-12-22T16:39:39Z (GMT). No. of bitstreams: 0 / Neste trabalho foi transfectada uma linhagem de células embrionárias de rim humano (HEK293) com os genes das subunidades α e β da tireotrofina humana (hTSH), hormônio glicoproteico secretado pela hipófise. Após 5 dias de cultivo obteve-se uma concentração de hTSH no meio condicionado de 0,95μg/mL. O material foi concentrado e purificado utilizando uma estratégia envolvendo duas etapas, uma cromatografia de troca catiônica e uma cromatografia líquida de alta eficiência (HPLC) de fase reversa, que permitiu uma recuperação de 55% e uma pureza >90%. O produto purificado (hTSH-HEK) foi analisado e comparado a uma preparação comercial obtida em células CHO (hTSH-CHO) e a uma preparação hipofisária (hTSH-Pit). A identidade e a pureza do hTSH-HEK foram avaliadas por métodos físicoquímicos e imunológico (espectrometria de massa MALDI-TOF, HPLC de exclusão molecular e de fase reversa, SDS-PAGE e ensaio imunoradiométrico). A porção glicídica do hTSH-HEK foi avaliada pela análise do perfil dos N-glicanos e o comportamento biológico deste hormônio foi avaliado por bioensaio in vivo e estudo farmacocinético. As 3 preparações apresentaram pureza equivalente (97%) e a massa molecular relativa do hTSH-HEK foi 2,1% menor do que a do hTSH-CHO e 2,7% maior do que a do hTSH-Pit. A maior hidrofobicidade relativa, avaliada por RP-HPLC, foi a do hTSH-HEK. Os N-glicanos identificados no hTSH-HEK foram do tipo complexo, apresentando predominantemente estruturas tri-antenárias, enquanto no hTSH-CHO e no hTSH-Pit as estruturas bi-antenárias foram predominantes. Foram detectadas diferenças significativas relacionadas à composição dos carboidratos para estas preparações, um teor muito menor de ácido siálico e muito maior de fucose foram observados no hTSHHEK. Foi confirmada a atividade biológica das 3 preparações, sendo a bioatividade do hTSHHEK 39% e 16% inferior à do hTSH-CHO e hTSH-Pit, respectivamente. A meia-vida circulatória do hTSH-HEK foi menor (1,5 X) que a do hTSH-CHO e a do hTSH-Pit (1,2 X). De acordo com esses resultados o hTSH-HEK pode ser considerado uma alternativa viável para aplicações clínicas especialmente por sua origem humana e composição de carboidratos. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
143

Study of optical properties of multi-crystalline Si and of heavily dislocated single-crystalline Si

Park, Seung Chul January 1999 (has links)
No description available.
144

The development of a CsI(TI)-photodiode array for remote geochemical sensing

Evans, Robert James January 1999 (has links)
No description available.
145

FTIR emission studies of chemical processes

Morrell, Claire January 2000 (has links)
No description available.
146

Estudo da eficiência de um detector HPGe por métodos semiempíricos e experimental

Marcio Drumond Costa Ferreira 23 August 2012 (has links)
Nenhuma / A espectrometria gama é uma técnica que proporciona informações diversas em uma única análise, além de ser rápida e não destrutiva. Por meio de um detector de radiação acoplado a um sistema eletrônico de aquisição de dados, a técnica identifica os radionuclídeos emissores gama em uma amostra com radioatividade natural ou induzida, bem como fornece informações para calcular as suas atividades, a partir do registro e análise do espectro gama. A eficiência é um dos principais parâmetros a ser considerado quando se trabalha com detectores de radiação gama. Seu conhecimento possibilita uma melhor exatidão na quantidade de quantuns de radiação que o detector pode registrar dentre o total que emerge da fonte ou da amostra em estudo. A eficiência pode ser determinada experimentalmente, por métodos teóricos e semiempíricos. Usualmente, a determinação por método experimental é a mais exata, porém exige a aquisição de mais dados, o que torna o procedimento mais trabalhoso. Por sua vez, os métodos teóricos e os semiempíricos são muito menos laboriosos, apesar dos riscos de apresentarem maiores incertezas. Neste trabalho, foi realizado um estudo comparativo para verificar se as equações de eficiência determinadas por métodos semiempíricos e experimental teriam desempenhos similares na determinação das concentrações elementares da amostra de referência IAEA/Soil7, em geometria puntual e não puntual, irradiadas no reator de pesquisa TRIGA MARK I IPR-R1. Por métodos semiempíricos, foram aplicados os programas KayZero for Windows, V. 2.42 específico para cálculo de concentração elementar no método k0 de Ativação Neutrônica e o ANGLE V3.0 desenvolvido para cálculo de eficiência de detectores semicondutores para diversas geometrias. Os resultados indicaram, por meio de avaliação estatística, que as eficiências determinadas experimentalmente e por métodos semiempíricos são similares e igualmente eficazes tanto para a amostra puntual quanto para a não puntual. As diferenças observadas nos resultados das concentrações elementares foram relacionadas às correções aplicadas pelo programa e não consideradas quando se usa a planilha eletrônica e não devido às eficiências determinadas. Este estudo mostrou também que o programa KayZero for Windows analisa e considera como puntual amostras com massa cinco vezes maior que a massa das amostras usualmente analisadas, o que expande o campo de aplicação do programa. / Gamma spectrometry is a technique that provides a piece of information on a sample in one measurement, in a fast and non destructive assay. Such technique identifies gamma emitter radionuclides in natural and induced radioactivity, using a radiation detector linked to an electronic system in order to acquire the data and gamma spectra. To determine the full energy peak efficiency of High-Purity Germanium detector is important for gamma-ray spectrometry experiments. The efficiency of a detector is proportionality constant, which relates the activity of the source being counted and the number of counts observed. This efficiency can be determined applying experimental methods, using theoretical and semi empirical methods. Usually, the determination via an experimental procedure is more accurate, however, it is necessary more data acquisition that makes the procedure more tiring. On the other hand, the theoretical and semi empirical methods are less laborious procedures, despite the risks of higher uncertainties. This comparative study was carried out in order to verify whether the full energy peak efficiency curves determined by experimental and semi empirical methods, would present a similar performance on elemental concentration of reference material IAEA/Soil7, prepared in punctual and non-punctual geometries, and irradiated in the TRIGA MARK I IPR-R1 research reactor. It was applied were applied the KayZero for Windows, V. 2.42 a specific software for elemental concentration determination in the k0-stardadization neutron activation analysis - and ANGLE V3.0 specific method to determine semi conductor detectors gamma efficiencies for several sample geometries. Based on statistical tests u-score and Relative Tendency - the results pointed out for two types of sample geometries, the efficiencies determined experimentally and by semi empirical methods are similar, which were fitted well and worked properly. The deviations observed in the results were related to corrections made by the KayZero for Windows software and didnt apply when the values were calculated using the spread sheet and not related to the efficiency curves themselves. Additionally, it was evidenced that KayZero for Windows software is able to analyze a non-punctual sample, with mass 5 times higher that the usual size, as it were punctual. It points out the versatility of the software and expands the application field.
147

Determinação da radioatividade natural de águas subterrânea e superficial de Brumadinho e Nova Lima, Brasil / Determination of natural radioactivity of groundwater and surface of Brumadinho and Nova Lima, Brazil

Lígia Santana de Faria 22 May 2013 (has links)
Nenhuma / Os municípios de Brumadinho e Nova Lima estão localizados na região metropolitana de Belo Horizonte. São municípios importantes por pertencer a uma Área de Proteção Ambiental inserida no Quadrilátero Ferrífero. Além da riqueza mineral, a região apresenta características geológicas que inclui conglomerados quartzítico associados ao urânio e um expressivo potencial hídrico subterrâneo com características hidrogeológicas bastante particulares e complexas como o aquífero quartzítico, pertencente à Formação Moeda. No presente trabalho foram realizadas medidas radiométricas em 44 amostras de água coletadas durante treze meses em quatro pontos distintos, três pontos situados em Brumadinho de natureza superficial e um ponto pertencente à Nova Lima de natureza subterrânea. Essas amostras tiveram o conteúdo de urânio e tório determinados a partir de um Espectrômetro de Massa com Plasma Acoplado Indutivamente. Foram avaliados as atividades de alfa total, beta total, radio 226, radio 228 e chumbo 210 usando a técnica de Espectrometria de Cintilação em Líquido no qual foi necessário a calibração do mesmo usando padrões de 241Am e 90Sr/90Y, de maneira a obter uma melhor discriminação / para determinação de alfa total e beta total. Os resultados obtidos foram comparados com as recomendações da Organização Mundial da Saúde, Ministério da Saúde e o Conselho Nacional do Meio Ambiente. Os níveis máximos de radioatividade natural da água encontrados foram 0,275 0,052 Bq.L-1 para alfa total, 0,130 0,046 Bq.L-1 para 226Ra e 0,096 0,005 Bq.L-1 para 228Ra. As concentrações de betal total e 210Pb ficaram abaixo do limite de detecção. Para as concentrações de urânio e tório os valores máximos encontrados foram 0,068 μg.L-1 e 0,027 μg.L-1 respectivamente. Palavras-chave: água, radioatividade natural, Espectrômetro de Massa com Plasma Acoplado Indutivamente, Espectrometria de Cintilação em Líquido. / The municipalities of Brumadinho and Nova Lima are located in the metropolitan area of Belo Horizonte city. They are of ecological interest since they belong to an Environmental Protection Area, which is located on a very important deposit of iron ore. In addition of mineral wealth, the region has a geological characteristic that includes quartzitic conglomerates associated with uranium and significant potential underground water with hydrogeological characteristics very particular and complex, as the Quartzite Aquifer, which belongs to a geological formation called the Moeda Formation. In the present work radiometric measurements were performed for 44 water samples. The samples were collected in four geographical points, three of them situated in Brumadinho (surface water) and one point situated in Nova Lima municipality (underground water). The period of sampling extended for a thirteen months period. Some of these locations was used as an alternative sampling point. Uranium and thorium concentrations of the samples were determined using an Inductively Coupled Plasma Mass Spectrometer. The content of gross alpha and gross beta activity, and the concentration of the radionuclides 226Ra,228Ra e 210Pb were determinate by using Spectrometer Liquid Scintillation. In this case was necessary to calibrate the spectrometer using 241Am e 90Sr/90Y standards. The resultants values were compared with those recommended by the World Health Organization, Ministry of Health and the National Council of the Environment. The maximum level of water natural radioactivity found was 0,275 0,052 Bq.L-1 for gross alpha radioation, 0,130 0,046 Bq.L-1 for 226Ra and 0,096 0,005 Bq.L-1 for 228Ra. The levels of gross beta activity and 210Pb were below the detection limit. The maximum concentrations of uranium and thorium found were 0,068 μg.L-1 and 0.027 μg.L-1 respectively.
148

Advancements in Radio Astronomical Array Processing: Digital Back End Development and Interferometric Array Interference Mitigation

Burnett, Mitchell Costus 01 December 2017 (has links)
The Brigham Young University (BYU) Radio Astronomy Systems group, in collaboration with the National Radio Astronomy Observatory (NRAO), the Center for Astrophysics at West Virginia University (WVU), and the Green Bank Observatory (GBO) have developed, and commissioned, a broadband real-time digital back end processing system for a 38-element phased array feed (PAF) with 150 MHz of instantaneous bandwidth. This system is capable of producing coarse and fine channel correlations, and implements a real-time beamformer that forms 7 simultaneous dual-polarized beams. This thesis outlines the hardware and software development for the digital back end and presents on-telescope commissioning results. This system has been measured to provide an unprecedented low Tsys/η noise level of 28 K and can perform maps of galactic hydrogen observations in a fraction of the time of a conventional single horn feed. The National Radio Astronomy Observatory (NRAO) has recently announced the concept and development of the next generation Very Large Array (ngVLA), a large interferometric array consisting of 300 radio telescopes and longest baseline (distance between a pair of antennas) of 300 km. Large interferometric arrays have been shown to attenuate radio frequency interference (RFI) because it is decorrelated as it propagates across long baselines. This is not always sufficient, especially with dense core array geometries and with the ever-increasing amount of strong RFI sources. Conventional RFI projection-based mitigation techniques have performed poorly on large interferometers because of covariance matrix estimation error due to decorrelation when identifying interference subspace parameters. This thesis presents an algorithm that overcomes the challenge of decorrelation by applying subspace projection via subarray processing (SP-SAP). Each subarray is designed to have a set of elements with high mutual correlation in the interferer for better estimation of subspace parameters. In simulation, compared to the former approach of applying subspace projection on the full array, SP-SAP improves mitigation of the RFI on the order of 9 dB. A signal of interest is shown then to be observable through the RFI in a full synthetic image.
149

Three-body Forces in Photoreactions on 3He

Silvia Niccolai January 2003 (has links)
Thesis; Thesis information not provided; 1 Feb 2003. / Published through the Information Bridge: DOE Scientific and Technical Information. "JLAB-PHY-03-39" "DOE/ER/40150-2763" Silvia Niccolai. 02/01/2003. Report is also available in paper and microfiche from NTIS.
150

Qualidade ambiental de solos agricolas da bacia do Rio Jaguari - Sao Paulo / Environmental quality of agricultural soils within the Jaguari River basin - São Paulo

RUBY, ELAINE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:55Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0861 seconds