• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 12
  • 5
  • 1
  • 1
  • Tagged with
  • 72
  • 38
  • 29
  • 17
  • 17
  • 17
  • 16
  • 16
  • 15
  • 14
  • 14
  • 14
  • 14
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Extraction de connaissances en imagerie microspectrométrique par analyse chimiométrique application à la caractérisation des constituants d'un calcul urinaire /

Elmi Rayaleh, Waïss Huvenne, Jean-Pierre. Duponchel, Ludovic January 2007 (has links)
Reproduction de : Thèse de doctorat : Instrumentation et analyses avancées : Lille 1 : 2006. / N° d'ordre (Lille 1) : 3813. Titre provenant de la page de titre du document numérisé. Bibliogr. p. 185-197.
12

Développements de méthodes d'acquisition et de traitement du signal robustes aux défauts du champ magnétique pour la spectroscopie localisée par RMN

Bordelois Boizán, Alejandro 25 October 2013 (has links) (PDF)
La spectroscopie localisée par Résonance Magnétique Nucléaire (RMN) a de nombreuses applications in vivo, car cette technique permet l'étude des métabolites endogènes. Cette thèse explore dans ce contexte diverses voies d'amélioration des données de spectroscopie. La première méthode présentée, est une méthode de correction de spectre mono-voxel. Une méthode de reconstruction pour l'imagerie spectroscopique s'appuyant sur la résolution d'un système d'équations linéaires au lieu de la transformation inverse de Fourier utilisée habituellement est ensuite proposée. Cette modification permet notamment la prise en compte des défauts du champ magnétique local. Enfin, une dernière méthode qui trouve son utilité lorsque le signal est trop faible pour permettre la quantification des signaux des métabolites ou lorsque les défauts du champ magnétique sont trop importants est développée puis validée par simulation et expérimentalement.
13

Développement d'une plateforme en optique intégrée en verres de chalcogénure pour des applications capteur pour le moyen infrarouge (OPTIMR) / Development of a chalcogenide optical integrated platform for sensing applications in the Mid-IR

Gutiérrez Arroyo, Aldo Jorge 09 May 2017 (has links)
Le moyen infrarouge est la région spectrale comprise entre 2 et 20 µm. Cette gamme de longueurs d'onde présente un fort intérêt scientifique grâce à la présence des transitions vibrationnelles fondamentales caractéristiques d'espèces moléculaires en phase liquide ou gazeuse. Les capteurs en optique intégrée sont devenus une excellente alternative pour la détection in situ car ils présentent certains avantages sur les autres types de capteurs, tels que l'intégration des éléments dans un dispositif compact. Ils sont capables d'effectuer des détections sélectives et quantitative dans divers domaines sociétaux tels que la santé, la défense et l'environnement. Dans cette thèse, nous présentons la conception, la fabrication et la caractérisation à 7.7 µm d'un transducteur spectroscopique intégré à base de verres de chalcogénures. Des couches à base de Ge-Sb-Se ont été déposées par pulvérisation cathodique RF magnétron. Des guides d'onde de type ridge ont ensuite été mise en forme, par photolithographie et gravure sèche (gravure ionique réactive) avec un plasma de CHF3. Différentes structures ont ainsi pu être réalisées : guides droits, jonctions Y, guide en spirale ou encore guides en S. En outre, la propagation guidée a été observé à 7.7 µm et des pertes de propagation égales à 2.5 dB/cm ont été mesurées à cette longueur d'onde. Enfin, des substances chimiques en phase liquide (isopropanol et acide acétique dissous dans du cyclohexane) ont été détectées par onde évanescente. Des limites de détection égales à 2 %v/v et 0.2 %v/v ont été, respectivement, démontrées à 7.7 µm pour l'isopropanol et l'acide acétique. Enfin, des simulations ont démontré le potentiel de ce capteur intégré pour la détection de substances polluantes contenues dans l'eau ou dans l'air avec des limites de détection inférieures à celles imposées par les normes internationales de l'environnement. L'ensemble de ces résultats représente une première étape prometteuse vers le développement d'applications dans le moyen Infrarouge au sein du laboratoire Foton. / The mid-infrared is a spectral range (2-20 µ m) of great scientific and technological interest. Indeed, the strong vibrational absorption bands of numerous molecules overlap this wavelength range. Thus, the mid-infrared has become in the last years a suitable solution for chemical sensing applications in gas or liquid phase. Furthermore, on-chip sensors provide several advantages over other kind of sensors, such as high integration of elements in a compact device and low fabrication cost by an easy-going to mass production. They could allow quantitative, sensitive and selective detection for health, defense and environmental applications. This thesis presents the design, fabrication and optical characterization at 7.7 µ m of a spectroscopic optical integrated sensor based on chalcogenide glasses. Ge-Sb-Se multilayered structures were deposited by RF magnetron sputtering. Using i-line photolithography and fluorine-based reactive ion etching (RIE-ICP), ridge waveguides were processed as straight waveguide, Y-junction, spiral and S-shape waveguides. Single-mode optical propagation at 7.7 µ m was observed by optical near-field imaging and optical propagation losses of 2.5 dB/cm were measured. Finally, chemical substances in liquid phase (isopropanol - and acetic acid, both dissolved in cyclohexane) were detected at 7.7 µ m by evanescent field. Limits of detection of 2 %v/v and 0.2 %v/v are demonstrated, respectively, for isopropanol and acetic acid. Furthermore, simulations were performed to assess the potential of the optical integrated sensor to achieve limits of detection lower than environmental and health standards for air and water pollutants. These results represent a first promising step towards the development of mid-infrared applications at the Foton laboratory.
14

Modelling of the instrument spectral response of conventionnal and imaging Fourier transform spectrometers

Kretschmer, Erik 20 April 2018 (has links)
La spectroscopie par la mesure du spectre optique est un outil dont on ne peut aujourd’hui plus se passer dans la grande majorité des laboratoires de chimie analytique et pour les applications de télédétection. À cet effet, l’usage de spectromètres par transformation de Fourier, les FTS (Fourier Transform Spectrometer), est très répandu. Parmi ces spectromètres, on trouve de plus en plus des instruments imageurs: les iFTS. À la différence des FTS classiques qui ne mesurent qu’un seul point, les iFTS mesurent un grand nombre de points d’une scène simultanément, ce qui ouvre la porte à des analyses spectrales sur des images. Les mesures spectrales effectuées par des FTS présentent certaines erreurs systématiques qui sont en grande partie décrites par la fonction de réponse spectrale de l’instrument, ou la SRF (Spectral Response Function). Dans le cas des instruments imageurs, chaque pixel possède sa propre réponse spectrale individuelle. Cela ouvre une toute nouvelle dimension dans l’analyse et la prédiction des erreurs systématiques de l’instrument. Grâce à la combinaison de la capacité d’imagerie et de télédétection des FTS imageurs, ce type d’instrument est souvent choisi pour des applications aérospatiales de sciences atmosphériques, tant pour l’étude de l’atmosphère terrestre que d’autre corps célestes. Ces applications sont toutefois très exigeantes et présentent des requis très stricts en matière de précision spectrale des instruments de mesure. Répondre à ces exigences sans une connaissance excellente de la réponse spectrale est impensable. La modélisation de la réponse des spectromètres permet d’obtenir une bonne connaissance des performances de ces instruments. Cette thèse propose d’abord une revue des effets affectant la réponse spectrale des FTS imageurs, pour ensuite présenter une nouveau modèle numérique de cette famille d’instruments. Ce modèle global de performance spectrale inclut des effets optiques généralement ignorés, simplifiés ou modélisés individuellement. La nécessité de modéliser ces effets, tels que ceux qui sont causés par la fonction de transfert optique de l’objectif du détecteur ou par l’architecture de la matrice de détecteur en plan focal (FPA), est démontrée par des usages exemplaires du modèle. Enfin, l’application du modèle comme support à l’analyse de performance du spectromètre imageur GLORIA est présentée. / Spectroscopy and the measurement of light spectrum have become essential tools in a large number of fields, from analytic laboratories to remote sensing field measurements. In these applications, the use of Fourier transform spectrometers (FTS) is widespread and, more recently, imaging Fourier transform spectrometers (iFTS) are becoming ever more popular. The iFTS instruments enable spatially resolved highresolution spectral analysis within a single measurement, thus allowing the study of fine spectral variations in observed scenes. Such measurements inherently include systematic errors which can be in large part described by the instrument spectral response function, often referred to as SRF. In the case of iFTS, each pixel of the instrument will sport a different spectral response, which opens a whole new dimension not only in the measurement itself, but also for error analysis and instrument design. Because of their unique imaging capacity, iFTS instruments are a prime choice for remote sensing applications from airborne or spaceborne platforms for the measurement of the Earth atmosphere, as well as the atmosphere of other celestial bodies. The requirements on the spectral accuracy demanded by such missions are very high. To achieve these requirements, an excellent knowledge of the instrument spectral response is essential. Modelling of the spectral response of iFTS instruments is a possible approach to achieve the desired knowledge of instrument performances. This thesis offers a review of the factors affecting the spectral performances of FTS instruments from which a numerical model of the spectral response specifically designed with imaging instrument in mind is proposed. This model integrates optical effects which were up to now only studied separately – if at all – and not integrated in a global performance model of the instrument. The necessity to consider these effects, such as those caused by the optical transfer function of the detector imaging optic or the architecture of the imaging focal plane array (FPA), is demonstrated. Using dedicated measurement of the airborne iFTS GLORIA (Gimballed Limb Observer for Radiance of the Atmosphere), the application of the model for performance analysis and review is demonstrated.
15

Dépôt de couches minces de SiCN par dépot chimique en phase vapeur assisté par plasma micro-onde : caractéristion du procédé et des films synthétisés dans un mélange N2/Ar/CH4/H2/hexaméthyldisilazane / SiCN thin film deposition by microwave plasma assisted chemical vapor deposition. Process and thin film characterisation in N2/Ar/CH4/H2/hexamethyldisilazane mixture

Bulou, Simon 05 November 2010 (has links)
Les films à base de Si, C et N présentent de très intéressantes propriétés mécaniques, optiques et électroniques. L'objectif de ce travail est de mettre au point le procédé de dépôt chimique en phase vapeur assisté par plasma micro-onde permettant l'élaboration, à partir d'hexaméthyldisilazane (HMDSN), de films minces de SiCN dont l'indice de réfraction et le gap peuvent être modulés en modifiant des paramètres expérimentaux. Un mélange à base de N2/Ar/HMDSN permet le dépôt de films durs, adhérents et transparents. Ceux-ci sont de type SiNx:H avec une faible teneur en carbone (< 20%). L'ajout de CH4 dans le mélange plasmagène ne modifie pas de façon très importante la composition des films mais change fortement leur structure.L'utilisation d?un mélange H2/Ar/HMDSN à la place du mélange N2/Ar/HMDSN aboutit à des films de type SiCx:H avec une teneur en N inférieure à 15 %. Les films ont alors un indice plus élevé (2.15) et un gap modéré (3.5 eV). L'ajout d'une petite quantité de N2 (< 5 %) dans le mélange change radicalement la composition du film. Les films sont alors de type SiNx:H avec un indice de l'ordre de 1.95 et un gap de 4.5 eV. L'indice et le gap peuvent alors être liés au taux de liaisons Si-C dans le film.Ce changement abrupt est probablement dû à deux effets combinés. D'une part, le carbone en phase gazeuse réagit avec l'azote pour former des espèces stables (CN, HCN) qui participent peu à la croissance. D'autre part, Si se lie préférentiellement avec N pour former des films de type SiNx:H. Une modulation des constantes optiques des films de SiCN via le taux de C peut ainsi être réalisée par l'ajout de très faibles quantités de N2 dans le mélange gazeux H2/Ar/HMDSN / Thin films made of Si, C, and N exhibit promising properties such as high hardness or wide tunable bandgap. This study concerns the deposition of SiCN thin films by MPACVD, whose optical properties can be changed by varying experimental deposition conditions. A gaseous mixture made of N2/Ar/hexamethyldisilazane(HMDSN) allows the synthesis of hard and transparent coating. The deposited material is very close to those of amorphous hydrogenated silicon nitride, with rather low carbon content. Effects on the films of different experimental deposition parameters are explored. CH4 addition to the N2/Ar/HMDSN gaseous mixture does not widely modify the chemical composition but leads to denser and smoother layers. H2/Ar/HMDSN plasma instead of N2/Ar/HMDSN results in thin films with a high C content. Thin film composition is closed to SiCx:H with N content lower than 15 %. Refractive index is high (2.15) and band gap (3.5 eV) is closed to that of SiC material. Addition of a small quantity of N2 (5 %) to the gaseous mixture leads to a sharp atomic composition change. The deposited material is closed to SiNx:H and exhibits a refractive index of 1.95 and a bandgap of 4.5 eV. These large modifications could be related to Si-C cross-links density. This dramatic change is probably due to two combined effects. On one hand, carbon in gaseous phase reacts with nitrogen and produces stable products, in particular CN and HCN. On the other hand, Si preferentially links with N than with C what results in material close to silicon nitride. Wide modifications of SiCN thin films optical properties can thus be obtained by adding very low N2 flow in H2/Ar/HMDSN plasma
16

Collectivité des noyaux de Zinc riches en neutrons par mesure de temps de vie avec le démonstrateur AGATA. Développement d'une cible d'hydrogène et physique aux énergies relativistes / Collectivity of neutron rich Zn nuclei by lifetime measurement with the AGATA Demonstrator. Development of a Hydrogen target and Physics at relativistic energies.

Louchart-Henning, Corinne 17 September 2012 (has links)
L’étude de la spectroscopie et de la structure des noyaux exotiques a permis ces dernières années de nombreuses découvertes par rapport à ce qu’on connaissait sur les noyaux stables : les noyaux peuvent être déformés et certains nombres magiques ne sont pas persistants lorsque l’on s’approche des drip line. Autour du 68Ni, qui présente des signes de fermeture de sous couche à N=40 (énergie d’excitation du 2+1 élevée et B(E2 ;2+->0+) faible), les noyaux exotiques tels les isotopes de Cr, Fe, Zn et Ge, présentent des déformations et les expériences récemment menées indiquent un développement rapide de la collectivité. L’expérience menée au LNL (Laboratori Nazionali di Legnaro) sur les isotopes 70,72,74Zn a conclu à la mesure d’une durée de vie étonnamment longue pour l’état 4+ du 74Zn, menant à un rapport entre B(E2; 4+ -> 2 +) et B(E2; 2+ -> 0+) très faible, non expliqué par les calculs au-delà du champ moyen ou de modèle en couche. Cette expérience a été l’une des premières de la campagne du démonstrateur AGATA.Deux types de réactions directes sont utilisées pour extraire les facteurs spectroscopiques, quantités reliées au nombre d’occupation des couches. Les valeurs trouvées expérimentalement ne sont pas consistantes entre elles dans le cas d’arrachage d’un nucléon très lié au noyau. Cette différence entre les deux mesures expérimentales pourrait provenir du fait qu’on ne modélise pas correctement le mécanisme de réaction des réactions d’arrachage d’un nucléon. Des calculs basés sur une approche d’une cascade intra-nucléaire suivie d’une phase d’évaporation tendent à montrer les insuffisances dans la modélisation actuelle des réactions. / The study of exotic nuclei spectroscopy and structure allowed, in the last years, numerous discoveries in respect to what is known from stable nuclei: nuclei can be deformed and the magic numbers are not persistent when moving toward the drip lines. Around 68Ni, which presents signs of shell closures at N=40 (high excitation energy of the 2+1 and low B(E2)), exotic nuclei, like Cr, Fr, Zn and Ge, present deformation and recent experiments point to rapid development of collectivity. The experiment done at LNL (Laboratori Nazionali di Legnaro) on 70,72,74Zn isotopes concluded a surprisingly long life time for the 4+ states of 74Zn, leading to a ratio of B(E2; 4+ -> 2 +) to B(E2; 2+ -> 0+) very low, not explicated by calculations beyond ,mean field or shell models. This experiment was one of the first of the AGATA demonstrator. Two types of direct reactions are used to extract spectroscopic factors, quantity linked to the shell occupation number. The experimental values are not consistent between the cases for the removal of one deeply bound nucleon in the nuclei. This difference between the two experimental measures could come from an incorrect modelization of the reaction mechanism or nucleon removal. Calculations based on intra-nuclear cascade followed by an evaporation phase show shortcomings in the current reaction models.
17

Détermination spectroscopique automatique de paramètres atmosphériques stellaires / Automatic spectroscopic determination of stellar atmospheric parameters

Wu, Yue 28 June 2011 (has links)
Les études Galactiques nécessitent de grands échantillons d'étoiles dont la masse, l'âge, les abondances, la vitesse et la distance sont connues. Les observations spectroscopiques permettent de mesurer certains de ces paramètres et les autres sont soit déterminés par d'autres moyens, ou dérivés par le calcul. Le besoin d'échantillons statistiquement représentatifs a motivé la construction d'instruments, et la réalisation de grands relevés comme le SDSS, LAMOST et GAIA... Ces projets génèrent une énorme quantité de données que les méthodes d'analyse interactives traditionnelles ne peuvent pas gérer. Cela a motivé des efforts pour concevoir des méthodes automatiques. Mon travail a commencé dans ce contexte, et les objectifs étaient de développer et tester une méthode automatique, puis de l'appliquer à des spectres stellaires à moyenne résolution. La thèse comporte quatre sections : 1. Je présente le package informatique ULySS, et en particulier son application à la détermination des paramètres atmosphériques des étoiles. 2. Nous avons utilisé ULySS pour déterminer les paramètres atmosphériques des 1273 étoiles de la bibliothèque CFLIB. 3. Nous avons appliqué la même méthode sur des observations obtenus pendant la mise en service de LAMOST et nous avons préparé une base de données de spectres de références pour les relevés futurs avec cet instrument. 4. Nous avons cherché des étoiles présumées pauvres en métaux (MP) en se servant des données de vérification scientifique de LAMOST. Cette étude contribue à l'étude des étoiles MP dans la Voie Lactée et montre la faisabilité de ces recherches avec LAMOST et ULySS / Galactic studies require large samples of stars with known mass, age, abundance, spatial velocity and distance etc. Spectroscopic observations allow ones to measure some of these parameters and to derive the others. The need for statistically representative samples motivated the construction of instruments and the realization of large surveys like SDSS, LAMOST and GAIA... These projects bring an enormous quantity of data that the traditional interactive spectral analysis methods cannot handle. This triggered efforts to design automatic methods. My work started in this context, and the goals were to develop and test an automatic method and to apply it to medium resolution stellar spectra. The thesis contains four sections: 1. The ULySS package, and in particular its application to the determination of the atmospheric parameters of stars is presented. 2. We used ULySS to determine the atmospheric parameters of the 1273 stars of the CFLIB library. 3. We applied the same method on LAMOST commissioning observations and we prepared stellar spectral templates for the future surveys. 4. We searched new metal-poor (hearafter MP) stellar candidates from LAMOST commissioning observations. The result of these MP star candidates is a prelude to the feasibility of LAMOST's capability on searching and enlarging the sample of MP stars in the Milky Way
18

Gravure de la grille en silicium pour les filières CMOS sub-0,1 µm

EL KORTOBI-DESVOIVRES, Latifa 17 November 2000 (has links) (PDF)
Ce travail de thèse s'inscrit dans le cadre des recherches avancées pour l'élaboration de la grille en silicium amorphe, pour les applications CMOS sub-0,1 µm. Cette étude a été menée sur la plate-forme de gravure du CNET, équipée de différents outils de caractérisation installés in situ. Dans un premier temps, nous avons développé un procédé de gravure à base de HBr/O2 permettant d'assurer une bonne anisotropie de gravure tout en ne générant aucun perçage de l'oxyde de grille très mince (< 2 nm). Au cours de l'optimisation de ce procédé, nous avons observé une augmentation de l'épaisseur de l'oxyde de grille. Grâce à différentes techniques d'analyses, nous avons montré que cette augmentation d'épaisseur est due à une oxydation et une amorphisation partielle du substrat de silicium sous l'oxyde de grille. Le deuxième volet de ce travail a porté sur une étude physico-chimique de la couche de passivation formée sur les flancs de la grille. Cette couche permet d'assurer l'anisotropie de gravure en bloquant toute gravure latérale. Par des analyses XPS, nous avons montré qu'elle se forme dès l'étape de gravure principale. Elle est constituée d'un 'sous' oxyde de silicium bromé. Pendant l'étape de surgravure, cette couche se densifie par substitution du brome par des atomes d'oxygène. Nous avons également montré que sa formation dépend fortement de la chimie utilisée, de l'énergie des ions, de la durée de la surgravure et de la dilution en oxygène. Des observations au microscope électronique à transmission ont révélé que cette couche est plus épaisse au sommet qu'au pied de la grille, favorisant ainsi l'apparition de défaut sous forme d'encoche au pied de la grille, le 'notching'.
19

Spectroscopie des noyaux legers deficients en neutrons: etude des noyaux 21Mg, 25Si et 26P; approche systematique du phenomene de l'asymetrie miroir; conception d'un detecteur a gaz pour l'etude de la radioactivite 2 protons

Thomas, Jean-Charles 01 October 2002 (has links) (PDF)
L'étude des modes de décroissance des noyaux 21 Mg, 25 Si et 26 P permet de tester la validité des modèles théoriques lorsqu'ils sont appliqués à la description des propriétés de noyaux particulièrement instables. Des approches de type <> ainsi que l'hypothèse d'indépendance de charge des forces nucléaires sont confrontées aux résultats expérimentaux. Enfin, l'observation du phénomène rare de l'émission de deux protons constitue le premier pas vers la recherche et l'étude de la radioactivité 2 He.
20

Couches minces et multicouches d'oxydes ferroélectrique (KTN) et diélectrique (BZN) pour applications en hyperfréquences

Le Febvrier, Arnaud 15 October 2012 (has links) (PDF)
Ces travaux de thèse avaient pour but de proposer et d'étudier des hétérostructures multicouches originales, associant un matériau ferroélectrique et un diélectrique à faibles pertes, en vue de les intégrer dans des dispositifs hyperfréquences. Ces dispositifs électroniques nécessitent des matériaux avec une agilité élevée en tension accompagnée de pertes diélectriques faibles. L'étude s'est focalisée sur le matériau ferroélectrique KTa1-xNbxO3 (KTN) qui a récemment montré de fortes potentialités dans des dispositifs agiles et le matériau diélectrique relaxeur Bi1,5-xZn0,9-yNb1,5O7-d (BZN). Ces deux matériaux ont tout d'abord été étudiés séparément (caractérisations structurales, microstructurales et physiques). Les propriétés diélectriques ont été mesurées à basses fréquences (100 kHz) et à hautes fréquences (1 à 67 GHz) sur des films de KTN non-dopés et dopés par MgO. Une étude poussée du matériau BZN a montré une forte dépendance des propriétés optiques et diélectriques avec la microstructure des films. Finalement, l'association des deux matériaux, proposée pour la première fois, a été développée par deux méthodes de dépôt (PLD et CSD). Les mesures diélectriques des multicouches BZN/KTN/substrat ont montré une forte réduction des pertes diélectriques de 76% à basses fréquences et de 21% à hautes fréquences. Ces multicouches présentent une accordabilité d'environ 3% sous 22 kV/cm, supérieure à ce qui a pu être mesuré sur des couches minces ou multicouches à base d'autres matériaux ferroélectriques à champ électrique équivalent.

Page generated in 0.0463 seconds