• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 4
  • 3
  • Tagged with
  • 13
  • 13
  • 13
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Radiation from an aperture into an anisotropic plasma half-space

Srikasem, Suthum January 1993 (has links)
No description available.
2

Avaliação da aplicação de um campo magnético permanente sepultado em área de enxerto ósseo alógeno e dento-alveolar : estudo experimental em ratos

Azambuja, Henrique Voltolini de January 2007 (has links)
Proposição: O presente trabalho propõe o estudo histológico descritivo da aplicação de um campo magnético sepultado, estático e permanente em área de enxerto ósseo alógeno liofilizado e dento-alveolar associada a defeito cirúrgico em mandíbulas de ratos. Metodologia: estudo experimental in vivo, randomizado. Amostra foi composta por 21 ratos, da espécie Rattus novergicus albinus, linhagem Wistar, machos, divididos em três grupos, correspondendo aos tempos experimentais de sete, 21 e 45 dias. Foram realizadas ostectomias associadas a odontossecções, na face lateral externa do corpo mandibular e no ramo ascendente, atingindo transversalmente a raiz do incisivo inferior e os ápices dos molares. Este defeito cirúrgico permitiu a adaptação de dispositivos metálicos magnetizados (grupo teste) e não magnetizados (grupo controle) associados às regiões apicais dos molares e ao coto distal do incisivo inferior, local este onde realizou-se enxertia óssea alógena liofilizada. A intensidade média do campo magnético sepultado e permanente foi de 250 gauss.Resultados: observou-se no grupo teste e controle, nos diferentes tempos experimentais a gradativa integração do enxerto ósseo alógeno liofilizado, a manutenção da vitalidade pulpar dos molares e coto proximal do incisivo inferior, além da contínua erupção do incisivo inferior do rato. Nos grupos teste, principalmente aos 45 dias, constatou-se uma diferenciada e exuberante neoformação óssea centrípeta em direção aos dispositivos metálicos imantados. Conclusão: o campo magnético sepultado in vivo foi capaz de favorecer o processo de cicatrização óssea no defeito cirúrgico criado. / Purpose: The present study provides a descriptive histological analysis of the use of a buried, static and permanent magnetic field in lyophilized bone allografts in a dentoalveolar area associated with surgical defects in rat mandibles. Method: a randomized in vivo experimental study was carried out with 21 male Wistar rats (Rattus norvegicus albinus), which were split into three groups, corresponding to 7, 21 and 45 experimental days. Ostectomies associated with odontotomies were performed on the outer lateral face of the mandibular body and in the ascending branch, cross-sectionally to the root of the lower incisor and to the molar apices. This surgical defect allowed for the use of magnetized (test group) and non-magnetized (control group) metal devices associated with molar apices and with the distal stump of the lower incisor, where the lyophilized bone allograft was performed. The intensity of the buried and permanent magnetic field amounted to 250 gauss. Results: In the test and control groups, there was gradual integration of the lyophilized bone allograft, maintenance of pulp vitality of the molars and of the proximal stump of the lower incisor, in addition to continuous eruption of the lower incisor. In the test groups, especially at 45 days, there was distinct and pronounced centripetal new bone formation in a direction toward the magnetized metal devices. Conclusion: the in vivo buried magnetic field favored bone healing at the site of the surgical defect.
3

Avaliação da aplicação de um campo magnético permanente sepultado em área de enxerto ósseo alógeno e dento-alveolar : estudo experimental em ratos

Azambuja, Henrique Voltolini de January 2007 (has links)
Proposição: O presente trabalho propõe o estudo histológico descritivo da aplicação de um campo magnético sepultado, estático e permanente em área de enxerto ósseo alógeno liofilizado e dento-alveolar associada a defeito cirúrgico em mandíbulas de ratos. Metodologia: estudo experimental in vivo, randomizado. Amostra foi composta por 21 ratos, da espécie Rattus novergicus albinus, linhagem Wistar, machos, divididos em três grupos, correspondendo aos tempos experimentais de sete, 21 e 45 dias. Foram realizadas ostectomias associadas a odontossecções, na face lateral externa do corpo mandibular e no ramo ascendente, atingindo transversalmente a raiz do incisivo inferior e os ápices dos molares. Este defeito cirúrgico permitiu a adaptação de dispositivos metálicos magnetizados (grupo teste) e não magnetizados (grupo controle) associados às regiões apicais dos molares e ao coto distal do incisivo inferior, local este onde realizou-se enxertia óssea alógena liofilizada. A intensidade média do campo magnético sepultado e permanente foi de 250 gauss.Resultados: observou-se no grupo teste e controle, nos diferentes tempos experimentais a gradativa integração do enxerto ósseo alógeno liofilizado, a manutenção da vitalidade pulpar dos molares e coto proximal do incisivo inferior, além da contínua erupção do incisivo inferior do rato. Nos grupos teste, principalmente aos 45 dias, constatou-se uma diferenciada e exuberante neoformação óssea centrípeta em direção aos dispositivos metálicos imantados. Conclusão: o campo magnético sepultado in vivo foi capaz de favorecer o processo de cicatrização óssea no defeito cirúrgico criado. / Purpose: The present study provides a descriptive histological analysis of the use of a buried, static and permanent magnetic field in lyophilized bone allografts in a dentoalveolar area associated with surgical defects in rat mandibles. Method: a randomized in vivo experimental study was carried out with 21 male Wistar rats (Rattus norvegicus albinus), which were split into three groups, corresponding to 7, 21 and 45 experimental days. Ostectomies associated with odontotomies were performed on the outer lateral face of the mandibular body and in the ascending branch, cross-sectionally to the root of the lower incisor and to the molar apices. This surgical defect allowed for the use of magnetized (test group) and non-magnetized (control group) metal devices associated with molar apices and with the distal stump of the lower incisor, where the lyophilized bone allograft was performed. The intensity of the buried and permanent magnetic field amounted to 250 gauss. Results: In the test and control groups, there was gradual integration of the lyophilized bone allograft, maintenance of pulp vitality of the molars and of the proximal stump of the lower incisor, in addition to continuous eruption of the lower incisor. In the test groups, especially at 45 days, there was distinct and pronounced centripetal new bone formation in a direction toward the magnetized metal devices. Conclusion: the in vivo buried magnetic field favored bone healing at the site of the surgical defect.
4

Avaliação da aplicação de um campo magnético permanente sepultado em área de enxerto ósseo alógeno e dento-alveolar : estudo experimental em ratos

Azambuja, Henrique Voltolini de January 2007 (has links)
Proposição: O presente trabalho propõe o estudo histológico descritivo da aplicação de um campo magnético sepultado, estático e permanente em área de enxerto ósseo alógeno liofilizado e dento-alveolar associada a defeito cirúrgico em mandíbulas de ratos. Metodologia: estudo experimental in vivo, randomizado. Amostra foi composta por 21 ratos, da espécie Rattus novergicus albinus, linhagem Wistar, machos, divididos em três grupos, correspondendo aos tempos experimentais de sete, 21 e 45 dias. Foram realizadas ostectomias associadas a odontossecções, na face lateral externa do corpo mandibular e no ramo ascendente, atingindo transversalmente a raiz do incisivo inferior e os ápices dos molares. Este defeito cirúrgico permitiu a adaptação de dispositivos metálicos magnetizados (grupo teste) e não magnetizados (grupo controle) associados às regiões apicais dos molares e ao coto distal do incisivo inferior, local este onde realizou-se enxertia óssea alógena liofilizada. A intensidade média do campo magnético sepultado e permanente foi de 250 gauss.Resultados: observou-se no grupo teste e controle, nos diferentes tempos experimentais a gradativa integração do enxerto ósseo alógeno liofilizado, a manutenção da vitalidade pulpar dos molares e coto proximal do incisivo inferior, além da contínua erupção do incisivo inferior do rato. Nos grupos teste, principalmente aos 45 dias, constatou-se uma diferenciada e exuberante neoformação óssea centrípeta em direção aos dispositivos metálicos imantados. Conclusão: o campo magnético sepultado in vivo foi capaz de favorecer o processo de cicatrização óssea no defeito cirúrgico criado. / Purpose: The present study provides a descriptive histological analysis of the use of a buried, static and permanent magnetic field in lyophilized bone allografts in a dentoalveolar area associated with surgical defects in rat mandibles. Method: a randomized in vivo experimental study was carried out with 21 male Wistar rats (Rattus norvegicus albinus), which were split into three groups, corresponding to 7, 21 and 45 experimental days. Ostectomies associated with odontotomies were performed on the outer lateral face of the mandibular body and in the ascending branch, cross-sectionally to the root of the lower incisor and to the molar apices. This surgical defect allowed for the use of magnetized (test group) and non-magnetized (control group) metal devices associated with molar apices and with the distal stump of the lower incisor, where the lyophilized bone allograft was performed. The intensity of the buried and permanent magnetic field amounted to 250 gauss. Results: In the test and control groups, there was gradual integration of the lyophilized bone allograft, maintenance of pulp vitality of the molars and of the proximal stump of the lower incisor, in addition to continuous eruption of the lower incisor. In the test groups, especially at 45 days, there was distinct and pronounced centripetal new bone formation in a direction toward the magnetized metal devices. Conclusion: the in vivo buried magnetic field favored bone healing at the site of the surgical defect.
5

Susceptibility effects in ultra-high field magnetic resonance imaging of the human brain

Truong, Trong-Kha 12 October 2004 (has links)
No description available.
6

Alterações comportamentais induzidas por Pentilenotetrazol e por Alprazolam em animais submetidos ao labirinto em cruz elevado e estimulados por campo magnético estático / Behavioral changes induced by Pentylenetetrazole and Alprazolam in animals in elevated plus-maze and stimulated by static magnetic field

Brito, Raquel Cardoso 20 February 2017 (has links)
Os campos magnéticos estáticos interferem com o sistema nervoso central lesado, modificando a atividade de diferentes estruturas e recuperando o comportamento afetado pela lesão. Esse trabalho tem por objetivo investigar os efeitos dos polos magnéticos em ratos Wistar saudáveis e as repercussões comportamentais no Labirinto em Cruz Elevado (LCE) induzidas por pentilenotetrazol (PTZ) e por Alprazolam (ALP) sob o efeito da estimulação magnética. EXPERIMENTO I - Foram utilizados 107 ratos albinos Wistar, machos, pesando entre 270 - 300g. Após quatro dias da implantação de um magneto (3200 Gauss) no crânio dos animais, esses foram submetidos à avaliação comportamental no LCE. Grupos injetados receberam, via intraperitoneal, 30 mg/kg de PTZ ou salina. Os dados obtidos foram analisados por ANOVA, as significâncias foram evidenciadas pelo pós-teste de Holm Sidak com valor de P significativo<0,05. Observamos diminuição no número de entradas nos braços abertos nos grupos PN, PTZ e SMPTZ em relação ao grupo C, e um aumento nas entradas do grupo PSPTZ sobre os grupos PTZ e SMPTZ (F6, 158= 1,91). Análise etológica revelou um aumento da apresentação do comportamento espreitar nos grupos PTZ, SMPTZ, PNPTZ, PSPTZ (F6, 79= 3,51), diminuição na apresentação dos comportamentos mergulho de cabeça (F6, 79= 2,40) e levantamentos (F6, 79= 17,64) nos grupos PN, PS, PTZ, SMPTZ, PNPTZ e PSPTZ em relação ao C. EXPERIMENTO II - Participaram 79 animais mantidos nas mesmas condições experimentais que no experimento I, injetados com Alprazolam (1mg/kg - intraperitoneal) ou salina. Observamos um aumento no número de entradas nos braços abertos nos grupos ALP e SMALP em relação ao grupo C (F6, 144= 3,53). A porcentagem de entradas nos braços abertos foi maior nos grupos ALP e SMALP em relação ao C (F6, 72= 2,41), e a porcentagem de tempo nos braços abertos foi maior no PNALP, comparado com o C (F6, 72= 3,95). A análise etológica revelou um aumento na frequência dos comportamentos mergulho de cabeça (F6, 72= 10,79) e exploração da extremidade final (F6, 72= 6,00) nos grupos ALP, SMALP e PNALP em relação ao C. Para o comportamento de levantamentos (F6, 72= 4,71) também observamos um aumento da frequência desse comportamento para os grupos ALP, SMALP e PSALP em relação ao C. No experimento I, o polo Sul conseguiu antagonizar o efeito do PTZ, na variável espaço-temporal entradas nos braços abertos, além disso, a estimulação magnética polo Norte, mimetizou o efeito do PTZ. No experimento II, ambos os polos magnéticos antagonizaram o efeito ALP na variável espaço-temporal entradas nos braços abertos. As variáveis etológicas também revelaram um antagonismo da resposta ALP, pelo polo Norte e pelo polo Sul. Dessa maneira, esse trabalho mostra através da análise comportamental no LCE que os campos magnéticos podem interferir de maneira distinta com as modificações no comportamento de ratos injetados com PTZ ou ALP / Static magnetic fields interfere with the injured central nervous system, modifying the activity of different structures and recovering the behavior affected by the lesion. The objective of this study was to investigate the effects of magnetic poles on healthy Wistar rats and the behavioral repercussions of the Penzolenotetrazole (PTZ) and Alprazolam (ALP) induction on the Elevated Plus-Maze (EPM) under the effect of magnetic stimulation. EXPERIMENT I - 107 male Wistar rats weighing between 270 and 300 g were used. After four days of implantation of a magneto (3200 Gauss) in the cranium of the animals, they were submitted to behavioral evaluation in the EPM. Injected groups received intraperitoneally 30 mg / kg of PTZ or saline. The data were analyzed by ANOVA, the significance was evidenced by the Holm Sidak post-hoc with a significant P value <0.05. We observed a decrease in the number of entrance open arms in the PN, PTZ and SMPTZ groups compared to group C, and an increase in the PSPTZ group on PTZ and SMPTZ groups (F6, 158 = 1.91). Ethological analysis showed an increase in the peeking out behavior in the PTZ, SMPTZ, PNPTZ, PSPTZ groups (F6, 79 = 3.51) and a decrease in the performance of the head dipping behavior (F6, 79= 2.40), and of rearing in PS, PTZ, SMPTZ, PNPTZ and PSPTZ in relation to C (F6, 79= 17.64). EXPERIMENT II - Participated 79 animals maintained in the same experimental conditions as in experiment I, injected with Alprazolam (1mg / kg - intraperitoneal) or saline. We observed an increase in the number of entrance into open arms in the ALP and SMALP groups compared to group C (F6, 144 = 3.53). And the percentage of open arms entries was higher in the ALP and SMALP groups than C (F6, 72 = 2.41), and the percentage of open arms time spented was higher in PNALP, compared to C (F6, 72 = 3.95). The ethological analysis revealed an increase in the frequency of head dipping behaviors (F6, 72 = 10.79) and end-arm activity (F6, 72 = 6.00) in the groups ALP, SMALP and PNALP in relation to C. Already for the rearing (F6, 72 = 4.71), we also observed an increase in the frequency of this behavior for the ALP, SMALP and PSALP groups in relation to C. In the experiment I, the South pole was able to antagonize the PTZ effect, as reported for the space-time variable in the open arms, besides the North pole magnetic stimulation, mimics the PTZ effect. In the experiment II, both magnetic poles antagonize the ALP effect in the space-time variable in the open arms. The ethological variables also revealed an antagonism of the ALP response, by the North and South poles. Thus, this work shows through the behavioral analysis in the EPM that the magnetic fields can interfere in a different way with the modifications in the behavior of injected rats with PTZ or ALP
7

Understanding the Interaction Between Blood Flow and an Applied Magnetic Field

Sinatra, Francy L. 27 October 2010 (has links)
Hemodynamic monitoring is extremely important in the accurate measurement of vital parameters. Current methods are highly invasive or noncontinuous, and require direct access to the patient’s skin. This study intends to explore the modulated magnetic signature of blood method (MMSB) to attain blood flow information. This method uses an applied magnetic field to magnetize the iron in the red blood cells and measures the disturbance to the field with a magnetic sensor [1]. Exploration will be done by experimentally studying in-vitro, as well as simulating in COMSOL the alteration of magnetic fields induced by the flow of a magnetic solution. It was found that the variation in magnetic field is due to a high magnetization of blood during slow flow and low magnetization during rapid flow. The understanding of this phenomenon can be used in order to create a portable, non-invasive, continuous, and accurate sensor to monitor the cardiovascular system.
8

Alterações comportamentais induzidas por Pentilenotetrazol e por Alprazolam em animais submetidos ao labirinto em cruz elevado e estimulados por campo magnético estático / Behavioral changes induced by Pentylenetetrazole and Alprazolam in animals in elevated plus-maze and stimulated by static magnetic field

Raquel Cardoso Brito 20 February 2017 (has links)
Os campos magnéticos estáticos interferem com o sistema nervoso central lesado, modificando a atividade de diferentes estruturas e recuperando o comportamento afetado pela lesão. Esse trabalho tem por objetivo investigar os efeitos dos polos magnéticos em ratos Wistar saudáveis e as repercussões comportamentais no Labirinto em Cruz Elevado (LCE) induzidas por pentilenotetrazol (PTZ) e por Alprazolam (ALP) sob o efeito da estimulação magnética. EXPERIMENTO I - Foram utilizados 107 ratos albinos Wistar, machos, pesando entre 270 - 300g. Após quatro dias da implantação de um magneto (3200 Gauss) no crânio dos animais, esses foram submetidos à avaliação comportamental no LCE. Grupos injetados receberam, via intraperitoneal, 30 mg/kg de PTZ ou salina. Os dados obtidos foram analisados por ANOVA, as significâncias foram evidenciadas pelo pós-teste de Holm Sidak com valor de P significativo<0,05. Observamos diminuição no número de entradas nos braços abertos nos grupos PN, PTZ e SMPTZ em relação ao grupo C, e um aumento nas entradas do grupo PSPTZ sobre os grupos PTZ e SMPTZ (F6, 158= 1,91). Análise etológica revelou um aumento da apresentação do comportamento espreitar nos grupos PTZ, SMPTZ, PNPTZ, PSPTZ (F6, 79= 3,51), diminuição na apresentação dos comportamentos mergulho de cabeça (F6, 79= 2,40) e levantamentos (F6, 79= 17,64) nos grupos PN, PS, PTZ, SMPTZ, PNPTZ e PSPTZ em relação ao C. EXPERIMENTO II - Participaram 79 animais mantidos nas mesmas condições experimentais que no experimento I, injetados com Alprazolam (1mg/kg - intraperitoneal) ou salina. Observamos um aumento no número de entradas nos braços abertos nos grupos ALP e SMALP em relação ao grupo C (F6, 144= 3,53). A porcentagem de entradas nos braços abertos foi maior nos grupos ALP e SMALP em relação ao C (F6, 72= 2,41), e a porcentagem de tempo nos braços abertos foi maior no PNALP, comparado com o C (F6, 72= 3,95). A análise etológica revelou um aumento na frequência dos comportamentos mergulho de cabeça (F6, 72= 10,79) e exploração da extremidade final (F6, 72= 6,00) nos grupos ALP, SMALP e PNALP em relação ao C. Para o comportamento de levantamentos (F6, 72= 4,71) também observamos um aumento da frequência desse comportamento para os grupos ALP, SMALP e PSALP em relação ao C. No experimento I, o polo Sul conseguiu antagonizar o efeito do PTZ, na variável espaço-temporal entradas nos braços abertos, além disso, a estimulação magnética polo Norte, mimetizou o efeito do PTZ. No experimento II, ambos os polos magnéticos antagonizaram o efeito ALP na variável espaço-temporal entradas nos braços abertos. As variáveis etológicas também revelaram um antagonismo da resposta ALP, pelo polo Norte e pelo polo Sul. Dessa maneira, esse trabalho mostra através da análise comportamental no LCE que os campos magnéticos podem interferir de maneira distinta com as modificações no comportamento de ratos injetados com PTZ ou ALP / Static magnetic fields interfere with the injured central nervous system, modifying the activity of different structures and recovering the behavior affected by the lesion. The objective of this study was to investigate the effects of magnetic poles on healthy Wistar rats and the behavioral repercussions of the Penzolenotetrazole (PTZ) and Alprazolam (ALP) induction on the Elevated Plus-Maze (EPM) under the effect of magnetic stimulation. EXPERIMENT I - 107 male Wistar rats weighing between 270 and 300 g were used. After four days of implantation of a magneto (3200 Gauss) in the cranium of the animals, they were submitted to behavioral evaluation in the EPM. Injected groups received intraperitoneally 30 mg / kg of PTZ or saline. The data were analyzed by ANOVA, the significance was evidenced by the Holm Sidak post-hoc with a significant P value <0.05. We observed a decrease in the number of entrance open arms in the PN, PTZ and SMPTZ groups compared to group C, and an increase in the PSPTZ group on PTZ and SMPTZ groups (F6, 158 = 1.91). Ethological analysis showed an increase in the peeking out behavior in the PTZ, SMPTZ, PNPTZ, PSPTZ groups (F6, 79 = 3.51) and a decrease in the performance of the head dipping behavior (F6, 79= 2.40), and of rearing in PS, PTZ, SMPTZ, PNPTZ and PSPTZ in relation to C (F6, 79= 17.64). EXPERIMENT II - Participated 79 animals maintained in the same experimental conditions as in experiment I, injected with Alprazolam (1mg / kg - intraperitoneal) or saline. We observed an increase in the number of entrance into open arms in the ALP and SMALP groups compared to group C (F6, 144 = 3.53). And the percentage of open arms entries was higher in the ALP and SMALP groups than C (F6, 72 = 2.41), and the percentage of open arms time spented was higher in PNALP, compared to C (F6, 72 = 3.95). The ethological analysis revealed an increase in the frequency of head dipping behaviors (F6, 72 = 10.79) and end-arm activity (F6, 72 = 6.00) in the groups ALP, SMALP and PNALP in relation to C. Already for the rearing (F6, 72 = 4.71), we also observed an increase in the frequency of this behavior for the ALP, SMALP and PSALP groups in relation to C. In the experiment I, the South pole was able to antagonize the PTZ effect, as reported for the space-time variable in the open arms, besides the North pole magnetic stimulation, mimics the PTZ effect. In the experiment II, both magnetic poles antagonize the ALP effect in the space-time variable in the open arms. The ethological variables also revealed an antagonism of the ALP response, by the North and South poles. Thus, this work shows through the behavioral analysis in the EPM that the magnetic fields can interfere in a different way with the modifications in the behavior of injected rats with PTZ or ALP
9

Résonance quadrupolaire de l'azote-14 : amélioration de la qualité spectrale et effet d'un champ magnétique statique de faible amplitude / Nitrogen-14 Nuclear Quadrupole Resonance (NQR) : improving the spectral quality and effect of a weak static magnetic field

Aissani, Sarra 20 June 2014 (has links)
La Résonance Quadrupolaire Nucléaire (RQN) est une technique spectroscopique appliquée à l’état solide et qui ne nécessite aucun champ magnétique statique contrairement à la Résonance Magnétique Nucléaire (RMN). Elle permet de détecter, les molécules qui contiennent un noyau quadrupolaire (tel que l'azote-14). La RQN de l’azote-14 suscite un intérêt particulier car elle s'avère utile dans la détection de drogues et d’explosifs, qui contiennent, pour la plupart, des molécules azotées. Cette thèse porte en premier lieu sur l’amélioration de la qualité spectrale en résonance quadrupolaire (RQN) de l’azote-14. Ainsi, nous nous sommes préoccupés des signaux transitoires (ringing) qui suivent l’impulsion radiofréquence (rf) et qui masquent en partie le signal RQN. Nous avons d’abord montré, par une étude théorique et expérimentale, que les mesures à basse puissance (< 3Watts) étaient possibles, ce qui nous a permis de diminuer l’amplitude du ringing. De plus, grâce à ce mode de fonctionnement (basse puissance), nous avons pu proposer un circuit original de commutation du facteur de qualité (Q-switch) basé sur un commutateur rf CMOS et qui a permis de diminuer la durée du ringing. La seconde partie traite de l’influence d’un champ magnétique statique faible amplitude et des divers paramètres expérimentaux en RQN de l’azote-14. Dans le cas où le tenseur de gradient de champ électrique est de symétrie axiale, nous avons observé des élargissements, voire des doublets Zeeman. En revanche, dans le cas général (absence de symetrie), nous avons mis en évidence la possibilité définir le tenseur de gradient de champ électrique à partir de la forme de raie d’une seule transition au lieu de deux transitions (sans champ magnétique statique). Ce dernier résultat pourrait permettre de diminuer de moitié le temps nécessaire à la caractérisation d’une nouvelle molécule azotée. / Nuclear quadrupole resonance (NQR) is a solid-state spectroscopic technique which doesn't require a static magnetic field in contrast to Nuclear Magnetic Resonance (NMR). It is used to detect molecules containing quadrupole nuclei (such as nitrogen-14). Nitrogen-14 quadrupole resonance is of particular interest because it is useful in the detection of drugs and explosives, which contain mostly of nitrogen molecules. In this thesis we have primarily focused on improving the spectral quality in nitrogen-14 quadrupole resonance (NQR) . Thus, we were concerned with the transient signals ( ringing ) following the radiofrequency (rf) pulse and which partly overwhelm the NQR signal. First, we demonstrated by theoretical and experimental study that low power measurements (< 3Watts ) were possible, allowing us to reduce the ringing amplitude. In addition, through this mode ( low power ), we have proposed an original quality factor switching circuit (Q -switch ) based on rf CMOS switch and which has reduced the ringing duration. The second part deals with the effect of a weak static magnetic field and various experimental parameters in nitrogen-14 quadrupole resonance. In the case of an axially symmetric electric field gradient tensor, we observed broadening or Zeeman doublets. By contrast, in the general case (no symmetry), we demonstrated the possibility to define the electric field gradient tensor from the line shape of a single transition instead of two transitions ( without static magnetic field ). This result reduces by half the time required for the characterization of a new nitrogen molecule.
10

Définition, validation et mise en place d’un suivi de l’exposition au champ magnétique statique des travailleurs en IRM / Development and validation of tools for static magnetic field monitoring of MRI workers

Delmas, Antoine 31 May 2017 (has links)
L'Imagerie par Résonance Magnétique (IRM) est une modalité d'imagerie médicale reposant sur l'utilisation de champs électromagnétiques pour acquérir des images tomodensitométriques du corps humain. Bien qu'appartenant à la catégorie des rayonnements non-ionisants (RNI), des effets transitoires peuvent être ressentis par les personnels travaillant à proximité d'une IRM. Ces travailleurs sont dits exposés aux champs électromagnétiques, même si les différents comités d’experts s’accordent pour dire qu’aucun effet d’accumulation de dose ou d’effet à long terme n’a été trouvé. Ces effets à court terme, allant d’un goût métallique au niveau de la bouche à la stimulation nerveuse et à l'échauffement, sont connus et identifiés. Ils peuvent néanmoins provoquer une gêne, voire un danger, pour le travailleur. Ces préoccupations concernent spécifiquement le champ magnétique permanent (de 1,5 T à 7 T) utilisé par l'IRM. Un groupement d'experts mandatés par l'Organisation Mondiale de la Santé (OMS) a ainsi déterminé l'évaluation de l'exposition des travailleurs au champ magnétique statique comme une priorité importante. Les travaux de cette thèse ont permis de répondre à cette demande en définissant et en implémentant un dispositif de mesure autonome et léger permettant la mesure de cette exposition ainsi que la caractérisation des mouvements du travailleur. La justesse de la mesure d'induction magnétique réalisée par le dispositif est garantie par une méthode de correction numérique prenant en compte les défauts de linéarité et d'orthogonalité du capteur. Basée sur les données du capteur, une méthode d'ajustement de la mesure d'induction magnétique a ensuite été définie. Cette méthode permet, à partir d'une mesure réalisée au niveau du torse du travailleur, d'extrapoler la valeur d'induction magnétique au niveau de la tête de celui-ci. Enfin, une validation pratique du dispositif de mesure a été effectuée à travers un suivi de l'exposition des travailleurs IRM de trois centres d'imagerie médicale : imagerie clinique, imagerie interventionnelle et IRM ultra hauts champs (7~T). Des méthodes d'extraction de métriques permettant l'analyse précise et la comparaison de l'exposition des travailleurs au champ magnétique statique ont été proposées. Les travaux présentés dans cette thèse ont ouvert des perspectives intéressantes, permettant de réaliser le suivi à long terme de l'exposition des travailleurs au champ magnétique statique de façon quasi autonome. De plus, une industrialisation des outils et méthodes définis a pu être réalisée et est actuellement en cours de validation / The Magnetic Resonance Imaging (MRI) is a medical imaging modality using electromagnetic fields (EMF) in order to perform human body tomodensitometric images. Even if these fields are Non-Ionizing Radiations (NIR), some transitory effects can be felt by the staff working in the vicinity of the MRI. Such workers are qualified as “exposed” to EMF, even if all expert comities agree to say that no accumulative or long term effects have been identified yet. Short term effects are known and identified, from metallic taste in the mouth, nerve and muscle stimulation, to biologic tissue heating, which can be troublesome or dangerous. The main exposure concern comes from the MRI permanent static magnetic field (ranging from 1.5 T to 7 T). An expert comity, mandated by the World Health Organization (WHO), has therefore defined the evaluation of the exposure of the MRI workers to the static magnetic field as a priority. This was the focus of this PhD thesis. A light and autonomous static magnetic field monitor (called "exposimeter") has been developed. It allows the recording of the three-dimensional magnetic fields as well as workers’ movements. Its magnetic induction measurement accuracy has been ensured by a specific calibration, which takes into account non-linearity and non-orthogonality of the magnetic sensors. Based on exposimeter data, a magnetic induction extrapolation method has then been developed. This method allows the estimation of the EMF exposure at the head with sensors placed on the torso. Finally, a practical validation of the device has been performed in multiple MRI clinical and research centers, included clinical MRIs (1.5 T and 3 T), an interventional MRI (1.5 T) and an ultra-high field MRI (7 T). Metrics have been defined in order to precisely analyze and compare workers exposure. All the works presented in this PhD thesis open new perspectives such as long term static magnetic field exposure follow-up. Moreover, industrial transfer of the device has been performed and is currently being validated

Page generated in 0.0787 seconds