Spelling suggestions: "subject:"stent"" "subject:"atent""
191 |
Avaliação dos níveis séricos de troponina I em pacientes submetidos à angioplastia coronariana com implante de stent / Evaluation of cardiac troponin I in patients undergoing coronary angioplasty with stent implantationVIEIRA, Nancy Helena Lopes da Silva 23 November 2009 (has links)
Made available in DSpace on 2014-07-29T15:29:19Z (GMT). No. of bitstreams: 1
dissertacao nancy vieira.pdf: 795865 bytes, checksum: dfeac68319198e6608dcf82885225d60 (MD5)
Previous issue date: 2009-11-23 / Bakground: The presence of an increase in troponin I (cTnI) is common in patients who have undergone a percutaneous coronary intervention (PCI), but it is questionable if the myocardial lesion occurring in the intervention allows one to identify patients with a greater risk of presenting adverse cardiac events (ACE) .Objective : The overall objective of the study was to evaluate the immediate evolution of cardiac troponin I (cTnI) in patients undergoing elective coronary angioplasty with stenting, and also compare patients with serum changes after the procedure of coronary angioplasty stenting, with the clinical variables and the occurrence of adverse cardiac events (ACE) following 12 months.. Methods: This is a study of a prospective cut, which evaluates 49 consecutive patients who underwent coronary angioplasty with stent implantation. A cTnI serum dosage was done both before and after the procedure. Patients with a cut off >1.0 ng/mL before implantation were excluded. All the others received follow up for one year, to record the presence of ACE (death, acute myocardial infarction, another angioplasty). Results: cTnI serum elevations occurred in 21(45.7%) of the patients after the PCI. At the end of the follow up period, 11(23.9%) of the patients presented adverse cardiac events. There was no association between the cTnI serum elevation and the presence of ACE in the follow up. Conclusions: The elevation of cTnI found after a coronary angioplasty with stent implantation was frequent in our sample, but these elevations in serum did not show any association with clinical variables and the occurrence of adverse cardiac events following 12 months / A presença da elevação da troponina I(cTnI) é comum em pacientes submetidos a uma intervenção coronariana percutânea (ICP), porém é questionado se a lesão miocárdica
ocorrida na intervenção permite identificar pacientes com maior risco de apresentar eventos cardíacos adversos. Objetivo: O objetivo geral do estudo foi avaliar o comportamento evolutivo imediato dos níveis séricos de troponina I (cTnI), em pacientes submetidos eletivamente à angioplastia coronária com implante de stent , e também, comparar pacientes com alterações séricas pós-procedimento de angioplastia coronária com implante de stent, com as variáveis clínicas e a ocorrência de eventos cardíacos adversos (ECA) no seguimento de 12 meses. Metodologia: Este é um estudo de coorte prospectivo, que avaliou 49 pacientes consecutivos, submetidos à angioplastia coronariana com implante de stent. Fez-se dosagens séricas de cTnI antes e após o procedimento. Pacientes com cut off > 1,0 ng/mL antes do implante foram excluídos, e os demais foram acompanhados em um ano de seguimento, para
registro da presença de ECA (óbito, infarto do miocárdio e nova angioplastia). Resultados: Ocorreram elevações séricas de cTnI em 21(45,7%) dos pacientes após a ICP. Ao término do seguimento 11(23,9%) dos pacientes apresentaram eventos cardíacos adversos. A correlação entre a elevação sérica da cTnI e a presença de ECA no seguimento não mostrou associação.
Conclusão: A elevação da cTnI encontrada após uma angioplastia coronariana com o implante de stent foi freqüente em nossa amostra, porém estas elevações séricas não apresentaram nenhuma associação com as variáveis clínicas e a ocorrência de eventos cardíacos adversos no seguimento de 12 meses
|
192 |
Image processing algorithms for the visualization of interventional devices in X-ray fluoroscopy / Algorithmes de traitement d'images pour la visualisation d'outils interventionnels dans des séquences de fluoroscopie par rayons XBismuth, Vincent 09 January 2012 (has links)
La pose de stent est l'option de traitement la plus courante de la maladie coronarienne, l'une des principales causes de mortalité dans le monde. Lors d'une procédure de pose de stent, le médecin insère des outils chirurgicaux dans le réseau vasculaire du patient. La progression de ces outils a l’intérieur du corps est suivie en temps réel sous uroscopie par rayons X. Trois outils, en particulier, jouent un rôle crucial dans la procédure : le guide, le ballon d'angioplastie et le stent. Le guide apparaît dans les images sous la forme d'une structure curviligne ne. Le ballon, monte sur le guide, est équipé de deux marqueurs radio-opaques à ses extrémités. Le stent est un maillage métallique qui se projette en une forme complexe dans les images uroscopiques. Le stent, dont le bon déploiement est essentiel au succès du geste médical, est souvent très difficilement visible dans les images. Les travaux présentés dans cette thèse poursuivent un double objectif. Il s'agit d'une part, de concevoir, d’étudier et de valider des techniques de traitement d'image visant à améliorer la visualisation des stents. D'autre part, nous étudions la traitement des structures curvilignes (comme les guides) pour lesquelles nous proposons un nouvel outil. Nous présentons des algorithmes de traitement d'image dédiés a la visualisation 2D et3D des stents. Nous sommes amenés, dans ce but, à détecter, suivre et recaler, de manière complètement automatique, les outils nécessaires a la pose de stent que sont le guide et le ballon. Le stent étant a peine visible dans les images, nous ne cherchons pas à le localiser directement à l'aide de techniques de traitement d'images. La position et le mouvement du stent sont déterminés par nos algorithmes […]. Nous avons évalué la performance des ces outils pour la visualisation des stents en 2D, sur une large base de près de 200 cas cliniques. Il en ressort que notre méthode surpasse les méthodes utilisées jusqu'ici sur le plan de la qualité image. La validation exhaustive que nous avons menée, confirme que nous avions atteint un niveau compatible avec son introduction commerciale. Le logiciel qui en résulte est désormais installé sur un grand nombre de sites cliniques, ou il est régulièrement utilisé. La méthode de visualisation 3D des stents que nous proposons utilise les marqueurs pour effectuer une reconstruction tomographique compensée en mouvement. Nous exposons des résultats préliminaires sur une base de 22 cas cliniques. Il semble que notre méthode surpasse les méthodes précédemment employées aussi bien du point de vue de la qualité d’image que de l'automatisation. Les méthodes de visualisation des stents que nous proposons s’appuient sur la segmentation de la portion du guide qui traverse le stent. Nous proposons un nouvel outil pour le traitement de telles structures curvilignes que nous appelons : l'Image de Chemins Polygonaux (acronyme PPI en anglais). Cet outil repose sur la notion de chemin localement optimal. L'un des principaux avantages du PPI est d’unir dans un même cadre différents concepts pré-existants. De plus, il permet de contrôler la régularité et la longueur des structures à traiter avec une paramétrisation simple et intuitive. Avant de tirer pleinement parti des performances du PPI nous proposons un schéma algorithmique efficace pour le calculer. Nous illustrons ces utilisation pour la segmentation automatique de guide où il surpasse les techniques existantes / Stent implantation is the most common treatment of coronary heart disease, one of the major causes of death worldwide. During a stenting procedure, the clinician inserts interventional devices inside the patient's vasculature. The navigation of the devices inside the patient's anatomy is monitored in real-time, under X-ray fluoroscopy. Three specific interventional devices play a key role in this procedure: the guide-wire, the angioplasty balloon and the stent. The guide-wire appears in the images as a thin curvilinear structure. The angioplasty balloon, that has two characteristic markerballs at its extremities, is mounted on the guide-wire. The stent is a 3D metallic mesh, whose appearance is complex in the fluoroscopic images. Stents are barely visible, but the proper assessment of their deployment is key to the procedure. The objective of the work presented in this thesis is twofold. On the first hand, we aim at designing, studying and validating image processing techniques that improve the visualization of stents. On the second hand, we study the processing of curvilinear structures (like guide-wires) for which we propose a new image processing technique. We present algorithms dedicated to the 2D and 3D visualization of stents. Since the stent is hardly visible, we do not intend to directly locate it by image processing means in the images. The position and motion of the stent are inferred from the location of two landmarks: the angioplasty balloon and of the guide-wire, which have characteristic shapes. To this aim, we perform automated detection, tracking and registration of these landmarks. The cornerstone of our 2D stent visualization enhancement technique is the use of the landmarks to perform motion compensated noise reduction. We evaluated the performance of this technique for 2D stent visualization over a large database of clinical data (nearly 200 cases). The results demonstrate that our method outperforms previous state of the art techniques in terms of image quality. A comprehensive validation confirmed that we reached the level of performance required for the commercial introduction of our algorithm. It is currently deployed in a large number of clinical sites worldwide. The 3D stent visualization that we propose, uses the landmarks to achieve motion compensated tomographic reconstruction. We show preliminary results over 22 clinical cases. Our method seems to outperform previous state of the art techniques both in terms of automation and image quality. The previous stent visualization methods involve the segmentation of the part of the guide-wire extending through the stent. We propose a generic tool to process such curvilinear structures that we call the Polygonal Path Image (PPI). The PPI relies on the concept of locally optimal paths. One of its main advantages is that it unifies the concepts of several previous state of the art techniques in a single formalism. Moreover the PPI enables to control the smoothness and the length of the structures to segment. Its parametrization is simple and intuitive. In order to fully benefit from the PPI, we propose an efficient scheme to compute it. We demonstrate its applicability for the task of automated guide-wire segmentation, for which it outperforms previous state of the art techniques
|
193 |
Přínos FDG PET/CT v diagnostice kardiovaskulárních zánětů. / The Value of FDG PET/CT in the Diagnosis of Cardiovascular Inflammation.Zogala, David January 2020 (has links)
1 Abstract Aim: To evaluate the diagnostic performance of FDG PET/CT in the detection of stent graft infection (SGI) with the use of visual and semiquantitative interpretation, to compare it with standalone CT analysis, to verify the transferability of the experience with FDG PET/CT in surgical prosthesis infection and to define the role of the method in the diagnostic algorithm of SGI. Subjects and Methods: In this retrospective study, two nuclear medicine physicians have independently analyzed 21 FDG PET/CT examinations performed in 20 subjects (16 men, 66 ± 8 years) between 2010 and 2019 for clinical suspicion of SGI. Six subjects examined from other reasons without signs of infection constituted a control group. The images were evaluated for the uptake pattern and intensity, and by the maximum standard uptake value (SUVmax), the target-to-background ratio with blood pool (TBRBP) and liver uptake (TBRhep) as a reference. The SGI was defined as the presence of focal hyperactivity with an intensity exceeding hepatic uptake. CT images were independently assessed for signs of SGI. Clinical review of all further patients' data served as the standard of reference. Results: Twelve cases were established as SGI by the clinical review. PET/CT correctly diagnosed SGI in eight and yielded a sensitivity of 92 % and...
|
194 |
Safety and efficacy of drug eluting stents vs bare metal stents in patients with atrial fibrillation: A systematic review and meta-analysisSambola, Antonia, Rello, Pau, Soriano, Toni, Bhatt, Deepak L., Pasupuleti, Vinay, Cannon, Christopher P., Gibson, C. Michael, Dewilde, Willem J.M., Lip, Gregory Y.H., Peterson, Eric D., Airaksinen, K. E.Juhani, Kiviniemi, Tuomas, Fauchier, Laurent, Räber, Lorenz, Ruiz-Nodar, Juan M., Banach, Maciej, Bueno, Héctor, Hernandez, Adrian V. 01 November 2020 (has links)
Objective: A systematic review and meta-analysis was performed to evaluate the safety and efficacy of drug-eluting stents (DES) vs bare-metal stents (BMS) in atrial fibrillation (AF) patients. Methods: We systematically searched 5 engines until May 2019 for cohort studies and randomized controlled trials (RCTs). Primary outcomes were major bleeding and major adverse cardiac events (MACE) including cardiac death, myocardial infarction, target vessel revascularization (TVR) or stent thrombosis. Effects of inverse variance random meta-analyses were described with relative risks (RR) and their 95% confidence intervals (CI). We also stratified analyses by type (triple [TAT] vs dual [DAT]) and duration (short-vs long-term) of antithrombotic therapy. Results: Ten studies (3 RCTs; 7 cohorts) including 10,353 patients (DES: 59.6%) were identified. DES did not show higher risk of major bleeding than BMS (5.6% vs 6.9%, RR 1.07; 95%CI, 0.89–1.28, p = 0.47; I2 = 0%) or MACE (12% vs 13.6%; RR 0.96; 95%CI 0.81–1.13, p = 0.60; I2 = 44%). Although, DES almost decreased TVR risk (6.4% vs 8.4%, RR 0.78; 95%CI, 0.61–1.01, p = 0.06; I2 = 15%). Stratified analyses by type and duration of antithrombotic therapy showed no differences in major bleeding or MACE between both types of stents. In DES, long-term TAT showed higher major bleeding risk than long-term DAT (7.7% vs 4.7%, RR 1.48, 95%CI 1.08–2.03, p = 0.01; I2 = 12%). For both types of stents, MACE risk was similar between TAT and DAT. Conclusions: In patients with AF undergoing PCI, DES had similar rate of major bleeding and MACE than BMS. DAT seems to be a safer antithrombotic therapy compared with TAT. / Janssen Pharmaceuticals / Revisión por pares
|
195 |
COMPUTATIONAL IMAGING AS APPLIED TO CORONARY ARTERY OPTICAL CO-HERENCE TOMOGRAPHYGharaibeh, Yazan 25 January 2022 (has links)
No description available.
|
196 |
Additive Manufacturing of NiTi Shape Memory Alloys with Biomedical ApplicationsSafdel, Ali January 2023 (has links)
This study focuses on the laser powder bed fusion processing of NiTi alloys and the feasibility of fabricating very thin stent structures for biomedical applications. A comprehensive correlation between the process and the material’s-structure and properties is established to facilitate the fabrication of NiTi alloys with tailored properties. In the first step, the impact of LPBF processing parameters and post-treatments on evolving the microstructure, texture, superelasticity, and asymmetry is examined. Subsequently, the feasibility of manufacturing very thin mesh structured stents is scrutinized followed by in-depth investigations into differently designed stents considering properties such as surface characteristics, mechanical properties, superelasticity, and recoverability. The obtained results and the represented discussions offer imperative insights, helping to better understand the complexity of the LPBF process and the present challenging aspects. Moreover, detailed contributions are made with the goal of paving the road ahead for the production of patient-specific NiTi stents with enhanced properties. / Thesis / Doctor of Philosophy (PhD)
|
197 |
Analyses médico-économiques de la prise en charge de la maladie coronarienne stable : méta-analyse en réseau et modélisationCaruba, Thibaut 27 September 2013 (has links) (PDF)
La maladie coronaire stable est une maladie chronique pour laquelle de nombreuses stratégies thérapeutiques sont disponibles, dont le traitement par médicaments seuls et les traitements invasifs par angioplastie avec stent ou par pontage aortocoronaire. Face aux résultats de plusieurs méta-analyses mettant en évidence un taux de mortalité comparable entre ces traitements, nous avons décidé d'effectuer un travail de recherche comparant leurs coûts. Dans la première partie de mon travail, nous avons comparé, après une période de un an et une autre de 3 ans de suivi des patients, les données cliniques et économiques publiées pour 5 traitements de l'angor stable : les médicaments seuls, le pontage aortocoronaire, l'angioplastie sans stent, l'angioplastie avec stent nu et l'angioplastie avec stent actif. La mortalité et le taux d'IDM étaient nos critères de jugement clinique. Les coûts directs, liés au traitement effectué et liés à la prise en charge des éventuelles complications, ont été uniformisés via la parité de pouvoir d'achat et exprimés en US $ 2008. Il s'agissait de notre critère de jugement économique. Un total de 19 études cliniques a été retenu dans notre méta-analyse en réseau. Nos résultats mettent en évidence une absence de différence significative sur le critère clinique. En revanche, nous avons observé une différence concernant le coût moyen de chaque traitement après un an et 3 ans de suivi. Le traitement le moins onéreux était le traitement par médicaments seuls, après un an et 3 ans de suivi, avec respectivement un coût moyen par patient de 3 069 US $ et 13 854 US $. Le coût moyen le plus élevé a toujours été obtenu avec le traitement par pontage aortocoronaire : 27 003 US $ après un an et 28 670 US $ après 3 ans de suivi. Cependant, nos conclusions sont limitées d'une part, par la variabilité des méthodes économiques utilisées dans les études sélectionnées dans notre méta-analyse et, d'autre part, par l'évolution des traitements dans le temps. Dans la seconde partie de mon travail de recherche, nous avons calculé le coût de prise en charge d'un patient angoreux stable traité par l'une des 4 stratégies thérapeutiques suivantes : médicaments seuls, pontage aortocoronaire, angioplastie avec stent nu et angioplastie avec stent actif. Pour se faire, nous avons défini d'une part 6 situations cliniques correspondant aux possibles états cliniques du patient un an après l'instauration du traitement étudié et, d'autre part, déterminé les quantités de soins consommés pour chacune de ces situations cliniques. La perspective retenue était celle de l'Assurance Maladie. Les coûts calculés étaient liés aux hospitalisations, aux soins ambulatoires et aux moyens de transport utilisés pour accéder à l'hôpital. La stratégie médicamenteuse était la moins onéreuse avec un coût moyen annuel de 1 518 € ; ce coût prenant en compte les probabilités de survenue des 6 états cliniques. Le traitement par pontage aortocoronaire était le plus onéreux des 4 traitements étudiés, avec un coût moyen annuel de 15 237 €. La perspective de mes travaux est de modéliser la prise en charge d'un patient angoreux stable en envisageant un second traitement si le premier traitement effectué conduit à une situation d'échec thérapeutique. Les arbres que nous avons construits nous permettront ensuite d'effectuer une analyse coût-efficacité de deux stratégies thérapeutiques avec une durée totale de suivi des patients de 2 ans. Enfin, si nos travaux mettent en avant l'intérêt économique du traitement par médicaments, nous soulignons que ces résultats sont obtenus après avoir suivi les patients sur une courte durée (études à un an et à 3 ans), alors que l'angor stable est une maladie chronique où les stratégies thérapeutiques peuvent se succéder en cas d'échec à l'un des traitements...
|
198 |
Variabilité de réponse au clopidogrel : bases biologiques, mécanismes, conséquences cliniques et alternatives thérapeutiques / Variability of clopidogrel response : biological description, mechanisms and genetics, clinical relevance and solutionsCuisset, Thomas 26 November 2010 (has links)
Les traitements antiplaquettaires représentent la pierre angulaire du traitement des patients admis pour syndrome coronaire aigu et/ou bénéficiant d’une angioplastie coronaire. L’association d’une bithérapie antiplaquettaire par aspirine et clopidogrel représente aujourd’hui le gold standard dans la prise en charge de ces patients. Malgré l’efficacité de ces molécules, les récidives d’événements ischémiques restent fréquentes, de l’ordre de 10% dans l’année suivant l’épisode clinique, et le concept de mauvaise réponse biologique au clopidogrel a été proposé comme une des hypothèses à ces récidives. En effet, de nombreuses études biologiques ont fait état d’une large variabilité interindividuelle de réponse biologique au clopidogrel, avec environ 20 à 30% des patients présentant un niveau d’inhibition plaquettaire sous traitement insuffisant. Dans ces travaux, cette réponse biologique a été évaluée par différents tests plaquettaires, les plus utilisés étant les tests de laboratoires (test d’agrégation et test VASP) et le test ‘minute’ Verify Now. Les mécanismes expliquant cette variabilité de réponse restent imparfaitement connus, mais des facteurs ont pu être clairement identifiés : polymorphismes génétiques, interactions médicamenteuses et facteurs cliniques comme le poids ou le diabète. Plus récemment, cette entité biologique a pu être reliée au pronostic clinique de nos patients avec un pronostic ischémique péjoratif chez les patients identifiés biologiquement comme mauvais répondeurs, et à l’inverse, un risque de complications hémorragiques accru chez les patients présentant la plus forte inhibition plaquettaire sous traitement. Devant ces constations, des solutions ont été proposées pour lutter contre cette mauvaise réponse comme une augmentation des doses de clopidogrel ou l’utilisation d’inhibiteurs de la glycoprotéine IIbIIIa. Ces stratégies ont apportés des résultats encourageants dans des études monocentriques, d’assez faibles effectifs. Toutefois, l’individualisation du traitement antiplaquettaire sur la base de ces tests n’est pas d’actualité, et devra attendre les résultats de larges essais multicentriques, actuellement en cours. Dans ce cadre, l’arrivée de nouveaux inhibiteurs de la voie de l’ADP, comme le prasugrel et le ticagrelor, pourront représenter des alternatives intéressantes chez ces patients à haut risque de récidive ischémique. / Antiplatelet therapy is the cornerstone therapy for patients admitted for acute coronary syndrome and/or undergoing percutaneous coronary intervention. Dual antiplatelet therapy with aspirin and clopidogrel is now the gold standard therapy for these patients. In spite of this effective association, recurrent events still occur and low response to clopidogrel has been proposed as one of the responsible factors. Indeed, numerous biological studies have described a broad interindividual variability of platelet response to clopidogrel, assessed with various platelet function tests such as light transmittance aggregometry, VASP phosphorylation index and the bed-side Verify Now assay. Mechanisms underlying this variability of response remain unclear and probably multifactorial, but factors have been clearly identified: genetic polymorphisms, medications interactions and clinical factors (diabetes, weight…). More recently, the clinical impact of this biological entity has been described with worse clinical outcome in patients non responder to clopidogrel, presenting a higher rate of recurrent ischemic events, including stent thrombosis. Meanwhile, a higher rate of bleeding complications have been found in patients with the highest on-treatment platelet inhibition, suggesting a ‘soft’ therapeutic window to avoid both types of recurrent events. Thus, several strategies have been proposed to overcome this poor response to the drug such as higher clopidogrel doses or additional GPIIbIIIa inhibitors in non responders. However, benefit of tailored therapy has been yet established in properly sized, prospective, randomized trial, which are currently ongoing. New comers in the class of P2Y12 inhibitors, prasugrel and ticagrelor, might represent a good alternative for these high-risk patients.
|
199 |
Désendothélialisation des anévrismes lors du traitement endovasculaire : une nouvelle approche pour prévenir les endofuitesBonneviot, Marie-Christine January 2008 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
|
200 |
Les aspects mathématiques des stents enrobésBourgeois, Étienne January 2006 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
|
Page generated in 0.0472 seconds