• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 33
  • 6
  • 1
  • Tagged with
  • 46
  • 28
  • 22
  • 19
  • 15
  • 12
  • 11
  • 11
  • 10
  • 8
  • 8
  • 7
  • 7
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Angio-RM morphologique et dynamique sans injection de contraste dans l'exploration des pathologies neurovasculaires à l'étage cervical et encéphalique / Neurovascular non-contrast-enhanced MRA

Raoult, Hélène 08 October 2014 (has links)
L’angio-RM est l’imagerie de choix pour l’exploration non invasive des pathologies neurovasculaires. Le développement de nouvelles séquences d’ARM sans injection, combinant des techniques d’acquisition innovantes tel l’arterial spin labeling au haut champ magnétique et à l’imagerie parallèle, laisse présager la perspective de résolutions spatiales et temporelles extrêmement intéressantes en des temps d’acquisition courts. Ces nouvelles séquences seraient ainsi une alternative avantageuse aux séquences habituelles et à l’imagerie de référence invasive qu’est l’artériographie. Nous nous sommes intéressés à l’optimisation de l’acquisition et du post-traitement de nouvelles séquences d’ARM sans injection dans deux contextes pathologiques particuliers, choisis de par leur pertinence en termes d’enjeu clinique et radiologique : la sténose carotidienne cervicale et la malformation artério-veineuse (MAV) encéphalique. La séquence « unenhanced carotid MRA » à l’étage cervical a été optimisée avec une lecture préférentielle du centre de l’espace k, une résolution spatiale isotropique et inframillimétrique, un temps d’acquisition de moins de 3 minutes, et un large volume couvert, sans la contrainte d’une synchronisation cardiaque. Elle a montré une qualité d’image supérieure au TOF grâce à une amélioration de l’homogénéité du signal intravasculaire et à une diminution des artéfacts de flux, avec une intensité de signal et un contraste artère/tissus supérieurs. Elle permettait une détection et une quantification précise des sténoses carotidiennes bulbaires chez les patients en comparaison avec l’angioscanner et permettait également de détecter les lésions infrapétreuses. Les perspectives sont d’améliorer le signal et le volume couvert pour proposer une séquence de dépistage rapide et synchrone des sténoses cervicales et encéphaliques. La séquence « 4D-SL MRA » à l’étage encéphalique a été optimisée avec un marquage de type IR-STAR et une série parabolique d'angles de bascule, une résolution temporelle inférieure à 70 ms et une fenêtre d’acquisition permettant d’analyser le drainage veineux en un temps d’acquisition de 7 minutes. Elle a permis une analyse fiable de l’angioarchitecture des MAV en comparaison avec l’artériographie et offre une délimitation précise du nidus, suggérant son intérêt pour l’évaluation du risque hémorragique et la décision thérapeutique. Un post-traitement dédié développé sous Matlab et SPM8 a permis d’améliorer la visualisation de l’arbre vasculaire et d’accéder à une quantification des paramètres hémodynamiques au sein de la MAV. Ainsi un ratio de « temps-au-pic-de signal » artériel/veineux bas apparaissait corrélé avec le risque de rupture des MAV. L’ARM 4D-SL pourrait permettre de tendre vers une nouvelle classification des MAVs, intégrant des paramètres hémodynamiques intra-MAV et des paramètres perfusionnels et microstructurels du parenchyme environnant, afin de proposer une prise en charge individualisée des patients. / MR angiography (MRA) is well adapted for noninvasive exploration of neurovascular pathologies. The development of innovative unenhanced MRA sequences, combining recent acquisition techniques like arterial spin labeling with high magnetic field and multichannel coils, allows to achieve high spatial and temporal resolution in short acquisition times. These innovative sequences may be proposed as alternatives to common MRA sequences and digital subtraction angiography (DSA) of reference. We focused on optimizing acquisition and post-processing of these sequences in two specific pathological contexts, because of their relevancy in terms of clinical and radiological challenges: cervical carotid stenosis and brain arteriovenous malformations (AVM). Cervical « unenhanced carotid MRA » imaging was improved with a preferential acquisition of the k-space center, an isotropic and submillimetric spatial resolution, an acquisition time below 3 min and a large coverage, not requiring any cardiac synchronization. This sequence showed an improved image quality with regards to TOF providing improved signal homogeneity and less flow artifacts, with higher signal intensity and arterial/tissue contrast. This sequence allowed an accurate detection and quantification of carotid stenosis in comparison with computed tomography angiography as well as the detection of infrapetrous lesions. Perspectives are improving signal and volume coverage in order to propose a fast and simultaneous screening of cervical and intracranial stenosis.Brain « 4D-SL MRA » imaging was improved with IR-STAR labeling and a parabolic flip angle pattern, a temporal resolution below 70 ms and an acquisition window allowing analysis of venous drainage, within 7 minutes. This sequence allowed a reliable analysis of AVM angioarchitecture in comparison with DSA and offered an accurate delineation of the nidus, thus suggesting its value for hemorrhagic risk assessment and therapeutic management. A dedicated post-processing using Matlab and SPM8 was developed to improve vascular network visualization and offer an access to hemodynamic quantification within the AVM. A low arterial to venous “time-to-peak” ratio seemed to be correlated with the rupture risk. 4D-SL MRA may pave the way for a novel AVM classification, integrating hemodynamic parameters within the AVM as well as perfusion and microstructural parameters in the surrounding tissue, in order to propose an individualized patient management.
2

Valeur prédictive thérapeutique relative de l'échographie Doppler et de la scintigraphie rénale pour l'hypertension rénovasculaire

Soulez, Gilles January 2000 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
3

Modélisation des stents en chirurgie cardiaque

Longo, Vito January 2003 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
4

Application du concept de perte de charge au diagnostic échocardiographique des sténoses aortiques

Garcia, Damien January 2003 (has links)
Thèse numérisée par la Direction des bibliothèques de l'Université de Montréal.
5

Valeur pronostique de la mesure IRM du volume rénal dans l'hypertension rénovasculaire avant angioplastie percutanée

Cliche, Andrée January 2006 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
6

Évaluation in vitro de resténoses intra-stent par échographie 3D mode main-libre

Lécart, Myriam January 2007 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
7

Athérosclérose et sténose valvulaire aortique : implication des macrophages et des cellules interstitielles de valve dans les calcifications cardiovasculaires / Atherosclerosis and aortic valve stenosis : implication of macrophages and valvular interstitial cells in cardiovascular calcifications

Rosa, Mickael 19 December 2016 (has links)
Les pathologies cardiovasculaires sont le plus souvent l’aboutissement des processus liés à l’athérosclérose. Elles représentent la première cause de morbi-mortalité dans le monde et leur incidence s’accroit avec le vieillissement de la population et l’expansion de facteurs de risques comme le diabète ou l’obésité. La sténose valvulaire aortique (SVA) est la valvulopathie la plus fréquente dans les pays développés présentant de nombreux points communs avec l’athérosclérose vasculaire. En plus des facteurs de risque, les lésions valvulaires et les lésions vasculaires partagent des similitudes dans les processus physiopathologiques impliqués comme l’inflammation, la fibrose, l’angiogenèse et la calcification. Ce dernier processus apparait dans les stades avancés des pathologies liées à l’athérosclérose et joue un rôle critique via son implication dans la stabilité de la plaque ou l’épaississement des cuspides valvulaires aortiques. Les macrophages, cellules issues de la différenciation des monocytes infiltrés, jouent un rôle prépondérant dans ces lésions via les phénotypes classiques (M1) et alternatifs (M2). Néanmoins cette dichotomie ne reflète pas complètement la variété de leur plasticité et les différents phénotypes induits notamment par le microenvironnement des monocytes/macrophages (zones riches en lipides, zones riches en fer ou zones riches en calcification). Dans la valve aortique, les cellules interstitielles de valve (VIC) forment la population cellulaire la plus présente au sein de la valve aortique. Ces cellules jouent un rôle déterminant dans le maintien du tissu valvulaire, mais également dans les processus de calcification menant à la SVA. Dans un premier temps, cette thèse a pour but d’étudier la capacité des macrophages à former des ostéoclastes, cellules responsables de la dégradation de la matrice osseuse, au sein des plaques d’athérosclérose. Dans un second temps, ce travail se focalisera sur les processus de calcification de la valve aortique via l’étude du rôle de la leptine dans les calcifications valvulaires (étude a priori) puis dans une étude transcriptomique sans a priori de VIC issues de valve sténosées et non-sténosées. Nos résultats sur les macrophages montrent ex vivo que les cellules en bordure des calcifications vasculaires sont des macrophages alternatifs de type M2. In vitro, ces cellules sont incapables de se différencier en ostéoclastes et de résorber une matrice osseuse. Pour l’étude de l’effet de la leptine sur les VIC, nous montrons que la leptine sérique est plus élevée chez des patients présentant une SVA, nous confirmons que la leptine et son récepteur sont exprimés au sein des valves aortiques et que la leptine favorise la différenciation ostéoblastique des VIC de manière dépendante des voies Akt et ERK. Enfin, l’étude transcriptomique a permis de mettre en évidence une nouvelle voie métabolique dérégulée dans les VIC. Cette enzyme est sous exprimée dans les VIC issues de valves pathologiques et dans les zones calcifiées des valves aortiques sténosées. Par ailleurs, le traitement des VIC par le produit de cette enzyme en milieu procalcifiant inhibe la calcification. Cette thèse met en avant de nouveaux indices sur les processus de calcification observés dans les plaques d’athérosclérose et les valves aortiques sténosées. Ces résultats décrivent l’impossibilité des M2 à former des ostéoclastes capables de résorber les calcifications. Il sera intéressant d’étudier le phénotype des macrophages en bordure des calcifications des valves aortiques sténosées. D’autre part, il sera intéressant d’étudier l’origine de la leptine dans la valve et son mécanisme d’action sur les VIC. Enfin, ce travail a mis à jour une nouvelle voie métabolique, impliquée dans le développement des calcifications valvulaires, qui pourrait constituer une voie thérapeutique innovante dans le traitement médicamenteux de la SVA. / Cardiovascular diseases (CVD) are the most often outcome of atherosclerosis processes. CVD are the first leading cause of death rate with an increasing incidence due to ageing populations and expansion of risk factors such as diabetes mellitus or obesity. Aortic valve stenosis (AVS) is the most frequent valvulopathy in developed countries sharing common points with vascular atherosclerosis. More than only risk factors, valvular and vascular lesions share common pathophysiological processes implicated in the development of the disease such as inflammation, fibrosis, angiogenesis and calcification. This last process appears in late stages of atherosclerosis diseases and play critical roles via implication in plaque stability or thickening of the aortic valve. Macrophages are cells deriving from infiltrated monocytes, playing an important role in the inflammatory state of lesions via classical (M1) or alternative phenotypes (M2) phenotypes. Nevertheless, this dichotomy does not reflect completely the variety of their plasticity and different phenotypes induced by the microenvironment of monocytes/macrophages (lipid riche zone, iron riche zone or calcium rich zone). In the aortic valve, valvular interstitial cells (VIC) are the most prominent cell type found in the aortic valve. These cells play a major role not only in the valve tissue homeostasis but also in the calcification processes leading to AVS. In a first part, the aim of this thesis is to elucidate the ability of macrophages to differentiate into osteoclasts, cell type responsible for bone matrix remodeling, inside atherosclerosis plaques. In a second part, this work will focus on the calcification processes occurring in the aortic valve via the study of the role of leptin in valvular calcification (association study) and then in a transcriptomic analysis of VIC isolated from calcified versus non calcified aortic valves (genome-wide expression study). Our results about macrophages show that ex vivo cell surrounding vascular calcification are alternative M2 macrophages. In vitro, these cells are no able to differentiate into true osteoclasts nor to resorb calcium deposits. Concerning the role of leptin on VIC, the results show that serum leptin is higher in patients with AVS, leptin and its receptors are expressed in the aortic valves and leptin enhances the osteoblast différenciation of VIC in an Akt and ERK dependant manner. Finally, the transcriptomic analysis allowed to highlight a new pathway deregulated in VIC. This enzyme is underexpressed in VIC isolated from calcified aortic valves and in the calcified zonesAbstract4of stenosed aortic valves. Otherwise, treating VIC with the product of this enzyme in a procalcifying medium inhibits calcification processes.This thesis highlights new insights into the calcification processes occurring in atherosclerosis lesions and calcified aortic valves. These results describe that M2 macrophages cannot differentiate into osteoclasts and reverse calcification formation inside atherosclerosis plaques. In parallel, it would be interesting to study the macrophages phenotypes surrounding calcium deposits in stenosed aortic valves. Then, it will be interesting to decipher the origin of leptin and its precise mechanism of action on VIC. Finally this work points out a new metabolic pathway implicated in the development of valvular calcification which could be a medical treatment of SVA.
8

Impact pronostique du débit cardiaque dans la sténose valvulaire aortique / Prognostic impact of cardiac output in aortic valve stenosis

Le Ven, Florent 13 December 2016 (has links)
La sténose aortique (SA) est la maladie valvulaire cardiaque ayant la plus forte prévalence dans les pays occidentaux. On s’aperçoit que, malgré le respect des recommandations pour les indications opératoires, les patients présentent des évolutions très variables après chirurgie : certains patients restent symptomatiques, décèdent précocement, ou présentent une dysfonction ventriculaire gauche persistante. Il a été montré que les patients présentant à la fois une SA en bas débit (c’est-à-dire un volume d’éjection bas), une fraction d’éjection ventriculaire gauche (FEVG) altérée et un gradient de pression entre le ventricule et l’aorte abaissé avaient un pronostic péjoratif, avec un risque opératoire majoré lorsqu’ils subissaient un remplacement valvulaire chirurgical. Il a aussi été récemment démontré que, dans le contexte de la SA, un bas débit peut survenir alors que la FEVG est normale. Les objectifs généraux de ce doctorat sont d’étudier l’impact du débit (plus précisément le volume d’éjection ventriculaire gauche) sur le pronostic des patients atteints de SA, ainsi que l’évolution du débit après intervention et les déterminants de son évolution. Les résultats indiquent que le volume d’éjection ventriculaire gauche, que ce soit avant intervention, ou son évolution après TAVI (Transcatheter Aortic Valve Implantation), sont des prédicteurs indépendants puissants de mortalité chez ces patients. / Aortic stenosis (AS) is the most common valvular heart disease in occidental countries. Despite proper use of the guidelines, some patients can present adverse outcomes after surgery: some of them remain symptomatic, some die prematurely, or suffer from a persistant left ventricular dysfunction. It has been demonstrated that patients presenting an AS with low flow (i.e. low stroke volume), impaired left ventricular ejection fraction (LVEF), and a low transvalvular mean gradient, have poor prognosis, with increased risk during aortic valve replacement surgery. It has also been demonstrated that, in AS, a low flow can occur despite a preserved LVEF. The main goals of this PhD were to evaluate the impact of flow (more precisely left ventricular stroke volume) on the prognosis of patients with AS, the evolution of flow after intervention, and the factors that influence it. The results show that left ventricular stroke volume, before or after intervention, or its evolution after TAVI (Transcatheter Aortic Valve Implantation), are powerful independant predictors of mortality.
9

Déterminants, mécanismes et conséquences de la dysfonction et du remodelage ventriculaire après remplacement valvulaire aortique : rôle des phénomènes inflammatoires / Determinants, mechanisms and consequences of ventricular remodeling and dysfunction after aortic valve replacement : role of inflammatory phenomena

Coisne, Augustin 28 June 2018 (has links)
Le rétrécissement aortique (RAo) est la valvulopathie la plus fréquente dans les pays industrialisés. Il entraine une augmentation chronique de la postcharge imposée au ventricule gauche (VG) se caractérisant par une hypertrophie ventriculaire gauche (HVG), une ischémie et une fibrose myocardique, une dysfonction diastolique et à long terme une insuffisance cardiaque. Indépendamment de la sévérité de la valvulopathie, plusieurs facteurs comme l’obésité, le diabète, l’insulinorésistance semblent influencer le remodelage ventriculaire dans cette condition. Ces troubles métaboliques sont associés à un état pro-inflammatoire, notamment du tissu adipeux, impliquant des médiateurs également associés à l’hypertrophie cardiomyocytaire et la fibrose myocardique. A l’heure actuelle, le remplacement valvulaire aortique (RVAo) chirurgical est le seul traitement ayant montré son impact sur la diminution de la morbi mortalité dans le RAo. Cette chirurgie est devenue peu risquée de nos jours et permet une diminution conséquente de la masse ventriculaire gauche (MVG) dans la première année. Néanmoins certains facteurs, en particulier un remodelage important en préopératoire et l’existence d’un mismatch patient-prothèse (PPM), semblent influencer le remodelage inverse après la chirurgie pouvant expliquer la persistance d’une fibrose myocardique ou de symptômes après l’opération. Nous avons émis les hypothèses suivantes : a) un état pro inflammatoire médié par le tissu adipeux épicardique (TAE) et les leucocytes circulants serait associé à un remodelage pathologique dans l’histoire naturelle du RAo, b) l’existence d’un PPM après RVAo serait associé à un moins bon pronostic indépendamment du poids corporel, c) l’horloge biologique jouerait un rôle dans la modulation de la réponse myocardique à un stimulus hypertrophique et à l’ischémie myocardique, d) l’apparition d’une dysfonction ventriculaire droite (VD) postopératoire, serait associée à un mauvais pronostic après RVAo. Nous avons donc inclus prospectivement les patients porteurs d’un RAo serré sans dysfonction VG, sans autre valvulopathie, adressés depuis 2009 au Centre des Valvulopathies du CHRU de Lille pour un premier RVAo. Une évaluation clinique, biologique ainsi qu’une échocardiographie transthoracique (ETT) pré et postopératoire (avant la sortie) ont été réalisées. Pour une partie de la population, différents prélèvements biologiques (sang et TAE) ont été effectués au moment du bloc opératoire afin de réaliser des analyses de transcriptomique sur le TAE et de cytométrie en flux sur les cellules sanguines circulantes. Une partie de la population a également été revue en ETT à 1 an et tous les patients ont été suivis à distance. Nous avons pu montrer que : a) la quantité de TAE était indépendamment associée à un remodelage VG plus sévère dans le RAo mais n’était pas associée à l’importance du remodelage inverse après RVAo. D’après nos premiers résultats, ce remodelage VG plus sévère semble associé à une dysrégulation de gènes impliqués dans la réponse immunitaire adaptative, dans la régulation de la réponse immunitaire et dans l’activation des cellules lymphocytaires T et également à un nombre de leucocytes et de monocytes circulants plus important, b) une surface fonctionnelle indexée de la prothèse aortique implantée lors du RVAo de moins de 0,85 cm²/m² était le paramètre valvulaire le plus puissant pour prédire les évènements cardiovasculaires à distance de l’opération chez les patients non obèses. De manière surprenante, chez les patients obèses aucune association n’était retrouvée entre cette surface fonctionnelle et le devenir des patients après RVAo, c) il existe une variation circadienne de la tolérance à l’ischémie-reperfusion imposée lors du RVAo [...] / Aortic stenosis (AS) is the most common valvular heart disease (VHD) in Western countries. It causes a chronic increase in left ventricular (LV) afterload characterized by left ventricular hypertrophy (LVH), ischemia and myocardial fibrosis, diastolic dysfunction and long-term heart failure. Regardless of the severity of stenosis, several factors such as obesity, diabetes, insulin resistance seems to impact the LV remodeling in this condition. These metabolic disorders are associated with a pro-inflammatory state, including adipose tissue, involving mediators perceived in cardiomyocyte hypertrophy and myocardial fibrosis. To date, surgical aortic valve replacement (SAVR) is the only option that has shown an impact on mortality. This surgery has become less risky and leads to a significant decrease in the left ventricular mass (LVM) in the first year. Nevertheless, some factors, including the existence of a patient-prosthesis mismatch (PPM), seem to influence this reverse remodeling after surgery, which may explain the persistence of myocardial fibrosis or symptoms after the surgery. We have made the following hypotheses: a) a pro-inflammatory state mediated by epicardial adipose tissue (EAT) and circulating leukocytes would be associated with pathological remodeling in the natural history of AS, b) the existence of a PPM after SAVR would be associated with a poorer prognosis regardless of body weight status, c) the circadian clock would play a role in modulating the myocardial response to a hypertrophic stimulus and myocardial ischemia, d) the onset of postoperative right ventricular (RV) dysfunction, would be associated with poorer prognosis after SAVR. We therefore prospectively included patients with severe AS without LV dysfunction, or another VHD, referred to our Heart Valve Center in Lille University Hospital since 2009 for a first SAVR. Clinical and biological evaluation and pre- and postoperative (before discharge) trans-thoracic echocardiography (TTE) were performed for all patients. In a sub-group of patients, biological samples (blood and TAE) were collected at the time of surgery to perform transcriptomic analysis on EAT and flow cytometry on the circulating blood cells. TTE was also performed 1-year after SAVR in a sub-group and all patients were followed-up for cardiovascular events. We found that: a) the amount of EAT was independently associated with worse LV remodeling in AS but not with the magnitude of reverse remodeling after SAVR. According to our first results, this more severe LV remodeling seems to be associated with dysregulation of genes involved in the adaptive immune response, in the regulation of the immune response and in the activation of T lymphocyte cells and also with a number of circulating leukocytes and monocytes more important, b) the indexed effective orifice area of the aortic prosthesis calculated by TTE with the unique cut-off of 0.85cm²/m² showed the best accuracy to predict major events after SAVR in lean or overweight patients but not in obese, c) perioperative myocardial injury is transcriptionally orchestrated by the circadian clock in patients undergoing SAVR, with poorer tolerance in patients operated on in the morning, d) heart failure is more frequently observed in patients operated on in the morning, unrelated to the occurrence of acute kidney injury after SAVR, e) the early and severe post-operative decline in RV longitudinal function reverses within a year and is not predictive of long-term outcomes after SAVR. Subsequently, we will continue to explore the link between adipose tissue and the natural course of LV remodeling, cardiovascular events after SAVR in particular the impact of circadian variations on the occurrence of heart failure and the RV function after SAVR.
10

Stabilité et dynamique des écoulements en géométrie de sténose

Griffith, Martin 03 December 2007 (has links) (PDF)
Les écoulements stationnaires et pulsés sont examinés dans deux géométries bloquées. Les géométries utilisées sont des modèles d'artères sténotiques, une condition commune ou une contraction localisée grandit dans une artère. Les géométries sont des modèles simplifiés de la réalité physiologique d'une sténose, l'intention de l'étude étant d'isoler et de décrire les caractéristiques fondamentales des écoulements sténotiques. L'étude se concentre sur l'effet de la variation du taux de blocage sur l'écoulement et sa stabilité. La première partie de la thèse présente une investigation de l'écoulement stationnaire à travers une conduite bidimensionnelle, avec une contraction asymétrique semi-circulaire. Les variations de la dynamique et de la stabilité et du sillage avec le nombre de Reynolds et le taux de blocage sont présentés. Le mode primaire de l'instabilité est décrit et son mécanisme déterminé analytiquement comme étant une instabilité elliptique. La deuxième partie concerne une géométrie cylindrique avec une contraction axisymétrique. Les écoulements stationnaires et pulsés sont examinés numériquement et expérimentalement. Numériquement, les différents modes linéaires d'instabilité sont identifiés. Expérimentalement, l'influence importante d'une instabilité convective est observée. Pour l'écoulement stationnaire, des comparaisons entre le comportement périodique de l'instabilité convective et la réponse d'un forçage sur l'écoulement stable sont effectuées. Pour l'écoulement pulsé, l'instabilité convective domine pour la plupart des cas considérés. La dépendance du nombre de Reynolds et du taux de blocage des deux formes d'instabilité est étudiée.

Page generated in 0.0381 seconds