Spelling suggestions: "subject:"bisulfato dde alumínio"" "subject:"bisulfato dde alumínico""
1 |
Avaliação em escala de bancada da remoção de Cylindrospermopsis raciborskii e cilindrospermopsinas pelo processo combinado de flotação e adsorção em carvão ativado utilizando quitosana e sulfato de alumínio como coagulantes / Bench scale removal of Cylindrospermopsis raciborskii and cylindrospermopsins through the combined processes of dissolved air flotation and adsorption onto activated carbon using chitosan and aluminum sulfate as coagulantsValencia-Cárdenas, Daniel 30 September 2016 (has links)
Dissertação (Mestrado)—Universidade de Brasília, Departamento de Engenharia Civil e Ambiental, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-12-23T16:25:10Z
No. of bitstreams: 1
2016_DanielValenciaCárdenas.pdf: 4643116 bytes, checksum: 22772c17252fd0b0f317903862c526d9 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2017-02-03T17:09:01Z (GMT) No. of bitstreams: 1
2016_DanielValenciaCárdenas.pdf: 4643116 bytes, checksum: 22772c17252fd0b0f317903862c526d9 (MD5) / Made available in DSpace on 2017-02-03T17:09:01Z (GMT). No. of bitstreams: 1
2016_DanielValenciaCárdenas.pdf: 4643116 bytes, checksum: 22772c17252fd0b0f317903862c526d9 (MD5) / Algumas cepas da Cylindrospermopsis raciborskii produzem cilindrospermopsinas como produto do seu metabolismo e, além disso, mesmo em condições normais, as estas são excretadas pelas células. Suas propriedades hidrofílicas permitem que sejam altamente solúveis em água, dificultando a sua remoção pelo ciclo convencional de tratamento de água. A flotação por ar dissolvido se destaca entre as alternativas tecnológicas que removem eficazmente células de cianobactéria, e consequentemente, as cianotoxinas intracelulares associadas às cianobactérias. A adsorção em carvão ativado pulverizado apresenta bons desempenhos na remoção da fração dissolvida de cianotoxinas. Nesse contexto, este estudo avaliou a remoção de células de C. raciborskii e de cilindrospermopsinas no processo combinado de flotação com adsorção em carvão ativado pulverizado, assim como a influência das condições de coagulação, propriedades do carvão e parâmetros operacionais na eficiência de remoção de células e toxina. Foram construídos diagramas de coagulação para a quitosana e o sulfato de alumínio, compreendendo as etapas de coagulação, floculação e flotação, para águas de estudo com densidade celular de C. raciborskii de ~106⁄. Além disso, foram feitos ensaios de adsorção de cilindrospermopsinas para dois carvões ativados pulverizados, os resultados foram comparados com as propriedades físicas de cada um e foi estimada uma dosagem de referência que foi usada nos ensaios do processo combinado de flotação e adsorção. A verificação da influência da taxa de aplicação superficial e da taxa de recirculação foi desenvolvida em colunas de flotação, usando as condições ótimas de coagulação e a dose de referência de carvão. Os resultados deste estudo revelaram que ambos os coagulantes apresentaram bom desempenho nos valores de pH entre 6,0 e 6,5, com dosagens de 0,5 e 9,0⁄ para quitosana e sulfato de alumínio, respectivamente. A adsorção de cilindrospermopsinas em carvão ativado foi favorecida pelo carvão com maior volume de microporos e área superficial, resultando em remoções de até 97% para toxinas dissolvidas em água deionizada e 85% para toxinas dissolvidas em água do lago Paranoá. A menor taxa de aplicação superficial em conjunto com uma taxa de recirculação de 10%, resultaram em máxima remoção de turbidez, cor aparente e clorofila-a. A remoção de cilindrospermopsinas, pelo processo combinado, foi influenciada majoritariamente pela dosagem de CAP e não pela taxa de aplicação superficial e de recirculação. O processo combinado de flotação com adsorção em carvão ativado demonstrou ser satisfatório na remoção de clorofila-a e cilindrospermopsinas, porém, sob as condições testadas, não foi possível garantir residuais de toxina na água clarificada compatíveis com a recomendação da portaria 2.914 de 1⁄. Entretanto, a aplicação de CAP interferiu nas remoções de turbidez e cor aparente, já que diminuiu a razão ⁄ nas taxas de recirculação testadas. / Some Cylindrospermopsis raciborskii strains produce cylindrospermopsins during metabolism. Furthermore, even in normal conditions, these toxins can be excreted. The cylindrospermopsins hydrophilic properties allow a high solubility that leads a weaker removal by the conventional water treatment. The dissolved air flotation (DAF) stands out as a great technique to remove both cells and intracellular toxins. The adsorption onto activated carbon shows a satisfactory performance adsorbing the dissolved toxin fraction. Hence, this study evaluated the removal of both C. raciborskii cells and cylindrospermopsins by the combining of dissolved air flotation and powdered activated carbon adsorption, as well as the coagulation conditions influence, some carbon properties and DAF project parameters on the global process efficiency. Coagulation diagrams were constructed, including coagulation, flocculation and flotation for waters spiked with ~106⁄ C. raciborskii, using chitosan and aluminum sulfate as coagulants. The adsorption onto powdered activated carbon (PAC) was studied using two different activated carbons. The adsorption data was compared in terms of physical carbon properties and a reference dosage were computed and applied in the combined process. The surface loading rate and recycle ratio were evaluated in a flotation column system, where were applied the optimal coagulant dose and the computed carbon dosage. The results reveal that great removals for both coagulants were achieved in pH values surrounding 6,0 and 6,5, and coagulant doses 0,5 and 9,0⁄ for chitosan and aluminum sulfate, respectively. The cylindrospermopsins adsorption was improved by the activated carbon porosity, showing better results with an activated carbon larger micropore volume and surface area, exhibiting 97% removal for cylindrospermopsins dissolved in deionized water and 85% for toxins dissolved in Paranoá lake water. The lowest surface loading rate with a recycle ratio of 10% exhibited higher turbidity, apparent color and chlorophyll-a removals. The cylindrospermopsins removal, by the combined process of DAF and adsorption onto PAC, was mostly influenced by the PAC dosage; and the surface loading rate and the recycle ratio had a minimal incidence. The combined process demonstrated a good performance for removal both cells and toxins, however the 1 ⁄ Brazilian standard recommendation was not reached. Nevertheless, the PAC addition inhered turbidity and color removal efficiencies because of ⁄ ratio decreasing at the tested recycle ratios.
|
2 |
Tratamento de águas residuárias oriundas da purificação do biodiesel por coagulação empregando sulfato de alumínio e quitosana : avaliação preliminar / Treatment of biodiesel wastewater by coagulation using aluminium sulfate and chitosan : preliminary assessmentGuimarães, Patrícia Sales 28 June 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia,
Departamento de Engenharia Civil e Ambiental, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2014-04-22T14:00:43Z
No. of bitstreams: 1
2013_PatriciaSalesGuimaraes.pdf: 1371281 bytes, checksum: 83cf44573c34361765b5b1e2badb0463 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-04-24T15:41:57Z (GMT) No. of bitstreams: 1
2013_PatriciaSalesGuimaraes.pdf: 1371281 bytes, checksum: 83cf44573c34361765b5b1e2badb0463 (MD5) / Made available in DSpace on 2014-04-24T15:41:57Z (GMT). No. of bitstreams: 1
2013_PatriciaSalesGuimaraes.pdf: 1371281 bytes, checksum: 83cf44573c34361765b5b1e2badb0463 (MD5) / O biodiesel é produzido comumente pelo processo de transesterificação a partir de óleos vegetais e/ou gordura animal que, quando de sua purificação, gera como subproduto uma água residuária misturada com grande quantidade de óleo e outros contaminantes, que impedem o seu descarte em corpos d’água receptores. Para a remoção desses óleos e graxas têm sido empregados processos eletrolíticos e físico-químicos que utilizam, em geral, coagulantes inorgânicos de sais metálicos. Entretanto, o processo de coagulação/floculação gera grande volume de lodo residual com alto teor de alumínio ou ferro de difícil disposição e tratamento. A quitosana tem se mostrado como alternativa de coagulante nos tratamentos de água para abastecimento e águas residuárias, por gerar pouco impacto ambiental e à saúde pública. A quitosana é um biopolímero biodegradável, obtido a partir da desacetilação da quitina, que gera uma quantidade reduzida de lodo e foi pouco estudada no tratamento de águas residuárias oleosas. Nesse contexto, esta pesquisa teve o objetivo de avaliar o desempenho do sulfato de alumínio e da quitosana como coagulantes no tratamento físico-químico para remoção da matéria orgânica de águas residuárias oriundas da purificação do biodiesel. Foram realizados, em escala de bancada, ensaios de coagulação/floculação/separação gravitacional por meio de Jar test, com valor de pH de coagulação entre 6,0 e 9,0. As doses de coagulantes avaliadas variaram de 0 a 0,3 g/L para sulfato de alumínio e de 0 a 0,8 g/L para quitosana. Os resultados deste estudo preliminar permitiram levantar hipóteses sobre as tendências dos efeitos da quitosana e do sulfato de alumínio no tratamento da água residuária de biodiesel e indicaram que a remoção da DQO é influenciada pelas características da água. Novos estudos devem ser realizados variando aspectos da metodologia para confrontar com os resultados aqui obtidos. _______________________________________________________________________________________ ABSTRACT / Biodiesel is commonly obtained by the transesterification process of vegetable oils and/or animal fats, as a byproduct generates a wastewater with large amounts of oil and other contaminants that hinder their disposal in water receivers. Electrolytic and physicalchemical technologies have been used to remove oil and grease from oily wastewater and the most commonly used coagulants are metal salts. However, the coagulation/flocculation process produces large volume of sludge with high concentration of aluminum or iron that is hazardous. Chitosan has been shown as an alternative coagulant in treatments of potable water and wastewater, by reducing environmental impact and public health. Chitosan is a biodegradable biopolymer, obtained by the deacetylation of chitin, which generates a reduced amount of sludge, and few studies have been done with it in the treatment of oily wastewater. In this context, this study evaluated the performance of aluminum sulphate and chitosan as coagulant in physical-chemical treatment to remove organic matter from biodiesel wastewater. Bench scale testing coagulation/flocculation/ gravitational separation were carried out through Jar test with pH range between 6.0 and 9.0. The doses of coagulants evaluated ranged from 0 to 0.3 g/L for aluminum sulfate, and from 0 to 0.8 g/L for chitosan. The results of this preliminary study allowed raising hypotheses on the trends of the effects of chitosan and aluminum sulfate in biodiesel wastewater, indicating that the COD removal is influenced by the wastewater characteristics. Further studies should be carried out varying parameters to compare with the results obtained here.
|
3 |
Remoção de células de Microcystis Aeruginosa em água de abastecimento por coagulação, floculação e sedimentação utilizando cloreto férrico e sulfato de alumínio e filtração por filtro de areiaOliveira, Erivanna Karlene dos Santos 11 April 2014 (has links)
Made available in DSpace on 2015-09-25T12:22:40Z (GMT). No. of bitstreams: 1
PDF - Erivanna Karlene dos Santos Oliveira.pdf: 2316361 bytes, checksum: a621cb80b0ca857fdd90fc5f90fbf6bf (MD5)
Previous issue date: 2014-04-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The presence of cyanobacteria in reservoirs, lakes and rivers is a global environmental
health problem as a result ofanthropogenic eutrophication. These microorganisms
hinder water purifiers, to produce taste and odor difficult to remove and the cells at high
density clog the sand filters, reducing its time of use. In the conventional method of
water treatment, coagulation, flocculation and sedimentation are essential in the removal
of cells and determine the efficiency of the following operations. In this study we
analyzed the efficiency of removal of intact cells of Microcystis aeruginosaand
microcystin-LR in the stages of coagulation, flocculation and sedimentation, followed
by filtration through sand filters with the use of coagulants ferric chloride and aluminum
sulfate, evaluating four filtration rates: 15, 30, 50 and 100 m
3
.m
-2
.d
-1
at pH 7.5 and a
dosage of 40 mg.L
-1
tests with a bench-scale (Jartest) using treated water dechlorinated
and adadded with a pureculture of M. aeruginosa with approximate final densityof 10
cel.mL
-1
simulating a bloom. The parametres control were turbidity, apparent color and
cell concentration. It was observed that both the efficiency rates at 15 and 30 m
1
had similar removal of apparent color, turbidity and cellconcentration (79%, 80% and
92% and 80%, 80,5% and 89,10% respectively for the coagulant ferric chloride. And for
aluminum sulphate was the same for both rates removals of 81,48% for apparent color,
turbidity to 83,25% and to 90,50% for cell concentration, since the rate for 30 m
1
removals were 83,33%, 83,25% and 89,71%, respectively. Nocell lysiswas
observedandconsequently, no further increases in concentrationsofmicrocystin-LR
cyanotoxinduring treatment was observed. / A presença de cianobactérias em reservatórios, lagos e rios é um problema mundial de
saúde ambiental, em consequência da eutrofização antropogênica. Esses microrganismos
dificultam a potabilização da água, por produzir gosto e odor difíceis de remover e suas
células em alta densidade colmatam os filtros, diminuindo sua vida útil. No método
convencional de tratamento de água, coagulação, floculação e sedimentação são
fundamentais na remoção de células e determinam a eficiência das operações seguintes.
Neste trabalho analisou-se a eficiência na remoção de células intactas de Microcystis
aeruginosa e da microcistina-LR nas etapas de coagulação, floculação e sedimentação,
seguido por filtração em filtro de areia com uso dos coagulantes cloreto férrico e sulfato
de alumínio, avaliando quatro taxas de filtração de 15, 30, 50 e 100 m
3
.m
, em pH 7,5
e dosagem de 40 mg.L
-1
com testes em escala de bancada (Jartest) utilizando-se água
tratada de torneira desclorada e adicionada de uma cultura pura de M. aeruginosa com
densidade final aproximada de 10
5
cel.mL
-1
simulando uma floração. Os parâmetros de
referência foram turbidez, cor aparente e concentração celular. Observou-se que a
eficiência, tanto com as taxas de 15 e 30 m
3
.m
-2
.d
-1
tiveram remoções semelhantes para as
variáveis cor aparente, turbidez e concentração celular com 79%, 80% e 92%; e 80%,
80,5% e 89,10%, respectivamente para o coagulante cloreto férrico. Para o sulfato de
alumínio e para ambas as taxas, houve a mesma reposta com remoções de 81,48% para
cor aparente, 83,25% para turbidez e 90,50% para concentração celular, já para a taxa de
30 m3
.m
-2
.d
-1
as remoções foram de 83,33% , 83,25% e 89,71% respectivamente. Não foi
observada lise celular e consequentemente, não houve aumentos, ao longo do tratamento,
das concentrações da cianotoxina microcistina -LR.
|
4 |
USO DO TANINO NO PROCESSO DE TRATAMENTO DE ÁGUA COMO MELHORIA EM SISTEMA DE GESTÃO AMBIENTAL. / USE OF THE TANNING BARK IN THE PROCESS OF WATER TREATMENT AS IMPROVEMENT IN ENVIRONMENTAL SYSTEMFiorentini, Viviane 09 June 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The present work carried through frigorific in Rio Grande do Sul state , had for objective to evaluate the use and application of the floculante agent tanning bark in the water treatment as well as of the deriving water of the effluent treatment station making possible its reuse. The evaluated
tecnology aims at to get improvement in the system of water management as a part of the environmental in slaughterhouses. For accomplishment of the ideal tanino s amount, the system Jar- test was used. Some tests in
Jar test had been carried through, for determination of the decantation floculante agent concentration as well as: its dosage, the ideal time of flocculation characteristics, turbid (NTU), pH. Was gotten better resulted with the dosage of 60 ppm of floculante agent, for a minimum turbidez of 0.63 NTU. When using these data evaluated new parameters as
hardness, fluorid, nitrate, nitrite,nitrogen,sulphate, aluminum, copper, iron magnesium and pH . Therefore with the application of the organic composition in study, it was improved optimism and improvement the treatment of water like that reducing the cost in 23 % an important tool of
improvement in the management system of the company in the water treatment process. / O presente trabalho realizado em Unidade Frigorífica no interior do Estado do Rio Grande do Sul, teve por objetivo avaliar o uso e aplicação do agente floculante tanino no tratamento de água bem como da água oriunda da estação de tratamento de efluentes, possibilitando a sua reutilização. A tecnologia avaliada visa obter melhoria no sistema de
gestão de águas, como uma parte do gerenciamento ambiental em frigoríficos. Para realização dos testes de eficiência de floculação e determinação de quantidade ideal utilizou-se o sistema do Jar-test. Foram realizados vários testes em Jar-test, para determinação da concentração do agente floculante, bem como: a sua dosagem, o tempo
ideal de floculação, características de decantação, turbidez (NTU), pH. Obteve-se melhores resultados com a dosagem de 60 ppm de agente floculante, para uma turbidez mínima de 0,63 NTU. Ao utilizar estes dados avaliou-se novos parâmetros como dureza, fluoreto, nitrato, nitrito,
nitrogênio, sulfato, alumínio, cobre, ferro, magnésio e pH. Por conseguinte com a aplicação do composto orgânico em estudo, aprimorou-se a otimização e melhoria no tratamento da água, desta forma, reduzindo os custos em 23%, uma importante ferramenta de melhoria no sistema de gestão ambiental da empresa no processo de tratamento de água.
|
5 |
Aplicação de sulfato de alumínio e taninos vegetais na coagulação-floculação de efluentes de curtumeAnjos, Patrícia Schacker dos January 2016 (has links)
A aplicação de sais de alumínio para tratamento de efluentes é questionada devido a possíveis impactos nocivos aos seres humanos e organismos vivos, em decorrência de residuais de alumínio remanescentes na água tratada e das quantidades de lodo sedimentado que contém o metal. Portanto, o uso combinado de sais metálicos e taninos vegetais, a fim de reduzir as concentrações do primeiro, aplicadas na coagulação-floculação de contaminantes dos efluentes é importante, inclusive pelas vantagens do uso de taninos, como polímeros orgânicos biodegradáveis. Assim, este trabalho visa aplicar sulfato de alumínio e taninos, em uso individual e em combinação, para remoção de contaminantes por meio de coagulação-floculação. Os ensaios foram realizados com três efluentes, um com elevada carga orgânica, um com baixa carga orgânica e um efluente de acabamento, todos de um mesmo curtume que realiza operações de acabamento molhado a acabamento final de couro wet-blue. No efluente de alta carga orgânica, foram testados 5 tipos de taninos em seis dosagens, e os taninos Tanfloc SM e Tanfloc SH, com melhor eficiência, também foram testados no efluente de menor carga orgânica, assim como o sulfato de alumínio, nas mesmas concentrações utilizadas inicialmente a fim de apresentar os resultados atingidos em efluentes com características de altas e baixas dosagens de químicos Após, foram realizadas combinações de sulfato de alumínio com Tanfloc SM e Tanfloc SH, em diferentes concentrações, e realizados ensaios nos três efluentes, com o intuito de apresentar a eficiência do uso combinado destes produtos em diferentes características de efluentes e verificar a redução das dosagens de sulfato de alumínio. Os melhores resultados obtidos na aplicação combinada de sulfato de alumínio e taninos, mostraram remoção de cor, turbidez e COT estatisticamente iguais à aplicação do uso individual destes, porém utilizando menores dosagens de sulfato de alumínio na composição. Assim, conclui-se que é possível realizar, de forma eficiente e satisfatória, o uso de misturas de sulfato de alumínio com taninos de forma a reduzir as dosagens de sulfato de alumínio, obtendo bons resultados de remoção de cor, turbidez e remoções superiores de COT quando comparadas com a aplicação de todos os coagulantes/floculantes individualmente. / The use of aluminum salts for the treatment of effluents is questioned due to possible harmful impacts on humans and living organisms with aluminum residuals remaining in the treated water and the quantities of sedimented sludge containing the metal. Therefore, the combined use of metal salts and vegetable tannins, in order to reduce the concentrations of the former, applied in the coagulation-flocculation of effluent contaminants is important, including the advantages of the use of tannins, such as biodegradable organic polymers. Thus, this work aims to apply aluminum sulfate and tannins, in individual use and in combination, to remove contaminants by means of coagulation-flocculation. The tests were carried out with three effluents, one with high organic load, one with low organic load and one finishing effluent, all from the same tannery that performs wet finishing operations with the final wet-blue leather finish. In the high organic matter effluent, five types of tannins were tested in six dosages, and Tanfloc SM and Tanfloc SH tannins with better efficiency were also tested in the less organic effluent as well as aluminum sulfate in the same concentrations used in order to present the results achieved in effluents with characteristics of high and low chemical dosages Afterwards, combinations of aluminum sulphate with Tanfloc SM and Tanfloc SH were carried out in different concentrations, and tests were carried out on the three effluents, in order to show the efficiency of the combined use of these products in different effluent characteristics and verify the reduction of the dosages of aluminum sulfate. The best results obtained in the combined application of aluminum sulphate and tannins showed color removal, turbidity and TOC statistically equal to the application of the individual use of these, but using lower dosages of aluminum sulphate in the composition. Thus, it is concluded that it is possible to efficiently and satisfactorily carry out the use of aluminum sulphate mixtures with tannins in order to reduce the dosages of aluminum sulphate, obtaining good results of color removal, turbidity and higher removals of COT when compared to the application of all coagulants/flocculants individually.
|
6 |
Análise de eficiência de biopolímero como composto coadjuvante no processo de coagulação-floculação e sedimentação / Biopolymer efficiency analysis as a coadjuvant compound in the coagulation-flocculation and sedimentation processAndrade, Erik de Lima [UNESP] 09 February 2017 (has links)
Submitted by Erik de Lima Andrade null (erik_andrade88@hotmail.com) on 2017-03-06T18:12:25Z
No. of bitstreams: 1
Dissertação_Erik de Lima Andrade.pdf: 2096082 bytes, checksum: fdfbde2d75d685f0c1cda5fc47b0b3f1 (MD5) / Approved for entry into archive by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br) on 2017-03-10T14:43:15Z (GMT) No. of bitstreams: 1
andrade_el_me_soro.pdf: 2096082 bytes, checksum: fdfbde2d75d685f0c1cda5fc47b0b3f1 (MD5) / Made available in DSpace on 2017-03-10T14:43:15Z (GMT). No. of bitstreams: 1
andrade_el_me_soro.pdf: 2096082 bytes, checksum: fdfbde2d75d685f0c1cda5fc47b0b3f1 (MD5)
Previous issue date: 2017-02-09 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A adequação no tratamento da água, para abastecimento público envolve a compreensão da vulnerabilidade de mananciais e de situações de risco à saúde humana. Da mesma forma, o sucesso do tratamento de água de superfície depende, fortemente, da eficácia do desempenho do coagulante. Com a qualidade dos mananciais comprometida por diferentes cenários, tornase indispensável, o processo de desenvolvimento de abordagens eficazes para as questões de caráter econômico e ambiental. O tratamento de água de superfície objetiva, de modo geral, a remoção de impurezas com o propósito de enquadrá-la no padrão de potabilidade, essencialmente, através do uso de produtos químicos. Neste sentido, o presente trabalho analisou a eficiência de três produtos comerciais: sulfato de alumínio, policloreto de alumínio e PGα21Ca. Para tanto, foram realizados ensaios de coagulação-floculação e sedimentação, em água da ETA de Salto de Pirapora, São Paulo, Brasil. Os resultados obtidos do PGα21Ca revelam caráter, essencialmente, inorgânico, com teores elevados de sulfato de cálcio (87%) e 5% de ácido γ-poliglutâmico, entre outros compostos químicos. O PGα21Ca apresentou maior eficiência de remoção de turbidez e cor aparente, com valores de 1,93 NTU de turbidez remanescente e 96,89% de remoção de cor aparente e pouca alteração no pH do meio, demonstrando efetividade para o tratamento de água para abastecimento público. O PAC apresentou resultados inferiores para clarificação da água quando comparado ao PGα21Ca e melhores resultados quando comparado ao sulfato de alumínio. Utilizando-se o PGα21Ca em água de Rio Grande, não obtém-se resultados tão expressivos quando comparado a água da ETA de Salto de Pirapora. / The suitability in the treatment of water for public supply involves understanding the vulnerability of sources and situations of risk to human health. Similarly, the success of surface water treatment depends strongly on the effectiveness of the coagulant performance. With the quality of water sources compromised by different scenarios, it is essential to the effective approaches development process for the economic and environmental character issues. The water treatment lens surface generally the removal of impurities in order to fit it in potable standard, mainly through the use of chemicals. In this sense, the present study examined the effectiveness of three commercial products: aluminum sulphate, polyaluminum chloride and PGα21Ca. Therefore, tests were carried out coagulation-flocculation and sedimentation in water of Salto de Pirapora WTP, São Paulo, Brazil. The results obtained reveal the character PGα21Ca essentially inorganic, with high levels of calcium sulfate (87%) and 5% γ-polyglutamic acid, and other chemical compounds. The PGα21Ca showed higher turbidity and apparent color removal efficiency, with values of 1.93 NTU turbidity and remaining 96.89% removal of apparent color and little change in pH of the medium, demonstrating the effectiveness for water treatment. The PAC presented lower results for clarification of water when compared to PGα21Ca and better results when compared to aluminum sulfate. Using PGα21Ca in Rio Grande water did not obtain significant results when compared to the water of the Salto de Pirapora WTP. / FAPESP: 2015/02650-8
|
7 |
Cinética de floculação de água bruta com baixa turbidez utilizando sais de alumínio e ferro como coagulante. / Flocculation kinetics of low-turbidity raw water using aluminum and iron salts as coagulants.Rodrigo de Oliveira Marques 15 December 2015 (has links)
Este trabalho teve como propósito investigar a cinética de floculação de água bruta com baixa turbidez, utilizando o sulfato de alumínio (Al2(SO4)3o18H2O) e o cloreto férrico (FeCl3o6H2O) como coagulantes. Os resultados experimentais foram obtidos em ensaios de \"jar test\". A água bruta utilizada nos ensaios foi preparada em laboratório, simulando um manancial superficial eutrofizado contendo células da cianobactéria Microcystis aeruginosa. Foram testadas 5 dosagens distintas de cada coagulante, 3 valores de G, 2 valores de TAS e 12 tempos de floculação. Utilizou-se a turbidez como medida principal de avaliação dos resultados experimentais. O valor de turbidez inicial (N0) foi corrigido, levando-se em consideração o acréscimo de turbidez em função das dosagens de coagulante. Determinou-se que as dosagens mais efetivas, em termos de remoção de turbidez, foram 20 mg.L-1 para o sulfato de alumínio e 40 mg.L-1 para o cloreto férrico (ambas expressas como massa de coagulante). Para ambos os coagulantes, constatou-se que G = 20 s-1 e TAS = 27 m3.m-2.dia-1 resultaram nas melhores eficiências de remoção de turbidez. Verificou-se também a variação do potencial zeta em função das dosagens de coagulante. Observou-se que o aumento da dosagem de coagulante leva à redução do potencial zeta, aproximando-o do ponto isoelétrico. Porém, o ponto isoelétrico não necessariamente coincide com a melhor eficiência em termos de remoção de turbidez. Com base nos resultados experimentais, foi proposta uma modificação ao modelo clássico da cinética de floculação de suspensões coloidais. Nesta, foi incluso um segundo termo referente à ruptura de flocos (quebra irreversível). O ajuste do modelo proposto foi obtido através de procedimentos de iteração numérica computacional com a função \"Solver\" do programa Microsoft Excel®. Foram calculados os valores das constantes KA, KB e KC do modelo proposto. Amostras do lodo gerado nos ensaios de cinética de floculação foram caracterizadas visualmente através de microscopia eletrônica de varredura (MEV). / The purpose of this work was to investigate flocculation kinetics of low-turbidity raw water, using aluminum sulfate (Al2(SO4)3o18H2O) and ferric chloride (FeCl3o6H2O) as coagulants. Experimental results were obtained in jar tests. Raw water used in the jar tests was prepared in laboratory, simulating a eutrophic natural water source containing cells of the cyanobacteria Microcystis aeruginosa. 5 different coagulant doses were tested for each coagulant, 3 G values, 2 SLR values and 12 flocculation times. Turbidity was selected as the major parameter for experimental results analysis. Initial turbidity values (N0) were corrected taking into account turbidity increase due to coagulant dosing. In terms of turbidity removal, it was determined that the most effective dosage for aluminum sulfate was 20 mg.L-1, and for ferric chloride, 40 mg.L-1 (both expressed as coagulant mass). For both coagulants, it was found that G = 20 s-1 and SLR = 27 m3.m-2.day-1 resulted in the best turbidity removal efficiencies. Zeta potential variation, due to coagulant dosing, was also verified. It was noted that increasing coagulant dosing led to zeta potential reduction, bringing it closer to the isoelectric point. However, the isoelectric point does not necessary coincides with the best turbidity removal efficiency. Based on the experimental results, it was proposed a modification to the classic colloidal suspension flocculation kinetics model. In this modification, a second term regarding floc rupture (irreversible breakage) was included. Through computer numeric iteration using Microsoft Excel®\'s \"Solver\" function, the proposed model adjustment was obtained. Kinetics constants KA, KB e KC values, from the proposed model, were calculated. Sludge samples, generated during flocculation kinetics tests, were visually characterized through scanning electronic microscopy (SEM).
|
8 |
Cinética de floculação de água bruta com baixa turbidez utilizando sais de alumínio e ferro como coagulante. / Flocculation kinetics of low-turbidity raw water using aluminum and iron salts as coagulants.Marques, Rodrigo de Oliveira 15 December 2015 (has links)
Este trabalho teve como propósito investigar a cinética de floculação de água bruta com baixa turbidez, utilizando o sulfato de alumínio (Al2(SO4)3o18H2O) e o cloreto férrico (FeCl3o6H2O) como coagulantes. Os resultados experimentais foram obtidos em ensaios de \"jar test\". A água bruta utilizada nos ensaios foi preparada em laboratório, simulando um manancial superficial eutrofizado contendo células da cianobactéria Microcystis aeruginosa. Foram testadas 5 dosagens distintas de cada coagulante, 3 valores de G, 2 valores de TAS e 12 tempos de floculação. Utilizou-se a turbidez como medida principal de avaliação dos resultados experimentais. O valor de turbidez inicial (N0) foi corrigido, levando-se em consideração o acréscimo de turbidez em função das dosagens de coagulante. Determinou-se que as dosagens mais efetivas, em termos de remoção de turbidez, foram 20 mg.L-1 para o sulfato de alumínio e 40 mg.L-1 para o cloreto férrico (ambas expressas como massa de coagulante). Para ambos os coagulantes, constatou-se que G = 20 s-1 e TAS = 27 m3.m-2.dia-1 resultaram nas melhores eficiências de remoção de turbidez. Verificou-se também a variação do potencial zeta em função das dosagens de coagulante. Observou-se que o aumento da dosagem de coagulante leva à redução do potencial zeta, aproximando-o do ponto isoelétrico. Porém, o ponto isoelétrico não necessariamente coincide com a melhor eficiência em termos de remoção de turbidez. Com base nos resultados experimentais, foi proposta uma modificação ao modelo clássico da cinética de floculação de suspensões coloidais. Nesta, foi incluso um segundo termo referente à ruptura de flocos (quebra irreversível). O ajuste do modelo proposto foi obtido através de procedimentos de iteração numérica computacional com a função \"Solver\" do programa Microsoft Excel®. Foram calculados os valores das constantes KA, KB e KC do modelo proposto. Amostras do lodo gerado nos ensaios de cinética de floculação foram caracterizadas visualmente através de microscopia eletrônica de varredura (MEV). / The purpose of this work was to investigate flocculation kinetics of low-turbidity raw water, using aluminum sulfate (Al2(SO4)3o18H2O) and ferric chloride (FeCl3o6H2O) as coagulants. Experimental results were obtained in jar tests. Raw water used in the jar tests was prepared in laboratory, simulating a eutrophic natural water source containing cells of the cyanobacteria Microcystis aeruginosa. 5 different coagulant doses were tested for each coagulant, 3 G values, 2 SLR values and 12 flocculation times. Turbidity was selected as the major parameter for experimental results analysis. Initial turbidity values (N0) were corrected taking into account turbidity increase due to coagulant dosing. In terms of turbidity removal, it was determined that the most effective dosage for aluminum sulfate was 20 mg.L-1, and for ferric chloride, 40 mg.L-1 (both expressed as coagulant mass). For both coagulants, it was found that G = 20 s-1 and SLR = 27 m3.m-2.day-1 resulted in the best turbidity removal efficiencies. Zeta potential variation, due to coagulant dosing, was also verified. It was noted that increasing coagulant dosing led to zeta potential reduction, bringing it closer to the isoelectric point. However, the isoelectric point does not necessary coincides with the best turbidity removal efficiency. Based on the experimental results, it was proposed a modification to the classic colloidal suspension flocculation kinetics model. In this modification, a second term regarding floc rupture (irreversible breakage) was included. Through computer numeric iteration using Microsoft Excel®\'s \"Solver\" function, the proposed model adjustment was obtained. Kinetics constants KA, KB e KC values, from the proposed model, were calculated. Sludge samples, generated during flocculation kinetics tests, were visually characterized through scanning electronic microscopy (SEM).
|
9 |
Aplicação de sulfato de alumínio e taninos vegetais na coagulação-floculação de efluentes de curtumeAnjos, Patrícia Schacker dos January 2016 (has links)
A aplicação de sais de alumínio para tratamento de efluentes é questionada devido a possíveis impactos nocivos aos seres humanos e organismos vivos, em decorrência de residuais de alumínio remanescentes na água tratada e das quantidades de lodo sedimentado que contém o metal. Portanto, o uso combinado de sais metálicos e taninos vegetais, a fim de reduzir as concentrações do primeiro, aplicadas na coagulação-floculação de contaminantes dos efluentes é importante, inclusive pelas vantagens do uso de taninos, como polímeros orgânicos biodegradáveis. Assim, este trabalho visa aplicar sulfato de alumínio e taninos, em uso individual e em combinação, para remoção de contaminantes por meio de coagulação-floculação. Os ensaios foram realizados com três efluentes, um com elevada carga orgânica, um com baixa carga orgânica e um efluente de acabamento, todos de um mesmo curtume que realiza operações de acabamento molhado a acabamento final de couro wet-blue. No efluente de alta carga orgânica, foram testados 5 tipos de taninos em seis dosagens, e os taninos Tanfloc SM e Tanfloc SH, com melhor eficiência, também foram testados no efluente de menor carga orgânica, assim como o sulfato de alumínio, nas mesmas concentrações utilizadas inicialmente a fim de apresentar os resultados atingidos em efluentes com características de altas e baixas dosagens de químicos Após, foram realizadas combinações de sulfato de alumínio com Tanfloc SM e Tanfloc SH, em diferentes concentrações, e realizados ensaios nos três efluentes, com o intuito de apresentar a eficiência do uso combinado destes produtos em diferentes características de efluentes e verificar a redução das dosagens de sulfato de alumínio. Os melhores resultados obtidos na aplicação combinada de sulfato de alumínio e taninos, mostraram remoção de cor, turbidez e COT estatisticamente iguais à aplicação do uso individual destes, porém utilizando menores dosagens de sulfato de alumínio na composição. Assim, conclui-se que é possível realizar, de forma eficiente e satisfatória, o uso de misturas de sulfato de alumínio com taninos de forma a reduzir as dosagens de sulfato de alumínio, obtendo bons resultados de remoção de cor, turbidez e remoções superiores de COT quando comparadas com a aplicação de todos os coagulantes/floculantes individualmente. / The use of aluminum salts for the treatment of effluents is questioned due to possible harmful impacts on humans and living organisms with aluminum residuals remaining in the treated water and the quantities of sedimented sludge containing the metal. Therefore, the combined use of metal salts and vegetable tannins, in order to reduce the concentrations of the former, applied in the coagulation-flocculation of effluent contaminants is important, including the advantages of the use of tannins, such as biodegradable organic polymers. Thus, this work aims to apply aluminum sulfate and tannins, in individual use and in combination, to remove contaminants by means of coagulation-flocculation. The tests were carried out with three effluents, one with high organic load, one with low organic load and one finishing effluent, all from the same tannery that performs wet finishing operations with the final wet-blue leather finish. In the high organic matter effluent, five types of tannins were tested in six dosages, and Tanfloc SM and Tanfloc SH tannins with better efficiency were also tested in the less organic effluent as well as aluminum sulfate in the same concentrations used in order to present the results achieved in effluents with characteristics of high and low chemical dosages Afterwards, combinations of aluminum sulphate with Tanfloc SM and Tanfloc SH were carried out in different concentrations, and tests were carried out on the three effluents, in order to show the efficiency of the combined use of these products in different effluent characteristics and verify the reduction of the dosages of aluminum sulfate. The best results obtained in the combined application of aluminum sulphate and tannins showed color removal, turbidity and TOC statistically equal to the application of the individual use of these, but using lower dosages of aluminum sulphate in the composition. Thus, it is concluded that it is possible to efficiently and satisfactorily carry out the use of aluminum sulphate mixtures with tannins in order to reduce the dosages of aluminum sulphate, obtaining good results of color removal, turbidity and higher removals of COT when compared to the application of all coagulants/flocculants individually.
|
10 |
Aplicação de sulfato de alumínio e taninos vegetais na coagulação-floculação de efluentes de curtumeAnjos, Patrícia Schacker dos January 2016 (has links)
A aplicação de sais de alumínio para tratamento de efluentes é questionada devido a possíveis impactos nocivos aos seres humanos e organismos vivos, em decorrência de residuais de alumínio remanescentes na água tratada e das quantidades de lodo sedimentado que contém o metal. Portanto, o uso combinado de sais metálicos e taninos vegetais, a fim de reduzir as concentrações do primeiro, aplicadas na coagulação-floculação de contaminantes dos efluentes é importante, inclusive pelas vantagens do uso de taninos, como polímeros orgânicos biodegradáveis. Assim, este trabalho visa aplicar sulfato de alumínio e taninos, em uso individual e em combinação, para remoção de contaminantes por meio de coagulação-floculação. Os ensaios foram realizados com três efluentes, um com elevada carga orgânica, um com baixa carga orgânica e um efluente de acabamento, todos de um mesmo curtume que realiza operações de acabamento molhado a acabamento final de couro wet-blue. No efluente de alta carga orgânica, foram testados 5 tipos de taninos em seis dosagens, e os taninos Tanfloc SM e Tanfloc SH, com melhor eficiência, também foram testados no efluente de menor carga orgânica, assim como o sulfato de alumínio, nas mesmas concentrações utilizadas inicialmente a fim de apresentar os resultados atingidos em efluentes com características de altas e baixas dosagens de químicos Após, foram realizadas combinações de sulfato de alumínio com Tanfloc SM e Tanfloc SH, em diferentes concentrações, e realizados ensaios nos três efluentes, com o intuito de apresentar a eficiência do uso combinado destes produtos em diferentes características de efluentes e verificar a redução das dosagens de sulfato de alumínio. Os melhores resultados obtidos na aplicação combinada de sulfato de alumínio e taninos, mostraram remoção de cor, turbidez e COT estatisticamente iguais à aplicação do uso individual destes, porém utilizando menores dosagens de sulfato de alumínio na composição. Assim, conclui-se que é possível realizar, de forma eficiente e satisfatória, o uso de misturas de sulfato de alumínio com taninos de forma a reduzir as dosagens de sulfato de alumínio, obtendo bons resultados de remoção de cor, turbidez e remoções superiores de COT quando comparadas com a aplicação de todos os coagulantes/floculantes individualmente. / The use of aluminum salts for the treatment of effluents is questioned due to possible harmful impacts on humans and living organisms with aluminum residuals remaining in the treated water and the quantities of sedimented sludge containing the metal. Therefore, the combined use of metal salts and vegetable tannins, in order to reduce the concentrations of the former, applied in the coagulation-flocculation of effluent contaminants is important, including the advantages of the use of tannins, such as biodegradable organic polymers. Thus, this work aims to apply aluminum sulfate and tannins, in individual use and in combination, to remove contaminants by means of coagulation-flocculation. The tests were carried out with three effluents, one with high organic load, one with low organic load and one finishing effluent, all from the same tannery that performs wet finishing operations with the final wet-blue leather finish. In the high organic matter effluent, five types of tannins were tested in six dosages, and Tanfloc SM and Tanfloc SH tannins with better efficiency were also tested in the less organic effluent as well as aluminum sulfate in the same concentrations used in order to present the results achieved in effluents with characteristics of high and low chemical dosages Afterwards, combinations of aluminum sulphate with Tanfloc SM and Tanfloc SH were carried out in different concentrations, and tests were carried out on the three effluents, in order to show the efficiency of the combined use of these products in different effluent characteristics and verify the reduction of the dosages of aluminum sulfate. The best results obtained in the combined application of aluminum sulphate and tannins showed color removal, turbidity and TOC statistically equal to the application of the individual use of these, but using lower dosages of aluminum sulphate in the composition. Thus, it is concluded that it is possible to efficiently and satisfactorily carry out the use of aluminum sulphate mixtures with tannins in order to reduce the dosages of aluminum sulphate, obtaining good results of color removal, turbidity and higher removals of COT when compared to the application of all coagulants/flocculants individually.
|
Page generated in 0.0701 seconds