• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1015
  • 29
  • 28
  • 28
  • 28
  • 27
  • 17
  • 11
  • 5
  • 4
  • 3
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 1068
  • 564
  • 280
  • 216
  • 190
  • 129
  • 127
  • 111
  • 103
  • 97
  • 89
  • 87
  • 81
  • 77
  • 73
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
621

Âncora de titânio na sutura iliofemoral para tratamento de luxação coxofemoral traumática em cães: descrição da técnica e estudo de 12 casos / Titanium anchor in iliofemoral suture as treatment for traumatic hip dislocation in dogs: technique and study of 12 cases

Rocha, Artur Gouveia [UNESP] 09 January 2017 (has links)
Submitted by ARTUR GOUVEIA ROCHA null (artur.rocha@gmail.com) on 2017-05-04T18:00:30Z No. of bitstreams: 2 ROCHA 2017 versao final com ficha catalografica.pdf: 1229911 bytes, checksum: 35986818153d6b4747eef4fcc6005df7 (MD5) ROCHA 2017 versao final com ficha catalografica.pdf: 1229911 bytes, checksum: 35986818153d6b4747eef4fcc6005df7 (MD5) / Rejected by Luiz Galeffi (luizgaleffi@gmail.com), reason: Solicitamos que realize uma nova submissão seguindo a orientação abaixo: O arquivo submetido não contém o certificado de aprovação. Corrija esta informação e realize uma nova submissão com o arquivo correto. Agradecemos a compreensão. on 2017-05-05T14:50:40Z (GMT) / Submitted by ARTUR GOUVEIA ROCHA null (artur.rocha@gmail.com) on 2017-08-07T14:07:12Z No. of bitstreams: 1 ROCHA 2017 versao final com ata.pdf: 1264869 bytes, checksum: 841da4fb1a6b499da585d46bc833bd0b (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-08-07T18:31:07Z (GMT) No. of bitstreams: 1 rocha_ag_dr_jabo.pdf: 1264869 bytes, checksum: 841da4fb1a6b499da585d46bc833bd0b (MD5) / Made available in DSpace on 2017-08-07T18:31:07Z (GMT). No. of bitstreams: 1 rocha_ag_dr_jabo.pdf: 1264869 bytes, checksum: 841da4fb1a6b499da585d46bc833bd0b (MD5) Previous issue date: 2017-01-09 / As técnicas cirúrgicas extra-articulares para estabilização do qua-dril luxado têm sido mais estudadas, tendo em vista a manutenção da integridade da cartilagem articular e a redução da progressão da doença articular degenerativa. Den-tre estas técnicas, a sutura de fixação iliofemoral, tem se mostrado efetiva, com boa recuperação dos pacientes. O propósito deste trabalho foi avaliar a âncora de titânio como método de fixação do fio se sutura ao ílio, substituindo, assim, na técnica de fixação iliofemoral, a trabalhosa manobra de passagem do material de sutura através de um túnel no corpo ilíaco. Esta técnica foi realizada em 12 cães, de raças variadas, atendidos no Hospital Veterinário da UNESP – Jaboticabal. Os pacientes, em sua to-talidade, vítimas de atropelamento, se apresentaram com diferentes graus de claudi-cação e dor no quadril. Em alguns casos, ocorreram reluxações após tentativas de redução fechada e esses pacientes foram submetidos redução e fixação cirúrgica da luxação por meio da sutura iliofemoral modificada. Os pacientes foram acompanhados clínica e radiograficamente por períodos variados entre 30 a 90 dias de pós-operatório. Observou-se apoio com carga no membro em média de três dias após os procedi-mentos e aos 10 dias a maioria dos pacientes não claudicava. Não foram visibilizadas, no exame radiográfico osteólise perimplante. A sutura ílio femoral, modificada pela utilização de uma âncora fixada ao ílio, mostrou-se eficiente no tratamento da luxação coxofemoral, não sendo observada recidiva da luxação. Adicionalmente, a utilização da âncora de titânio facilitou sobremaneira a fixação do fio ao ílio, reduzindo significa-tivamente o tempo cirúrgico. / Extra-articular surgical techniques for stabilization of dislocated hip have been most studied, with a view to maintaining the integrity of articular cartilage and reducing the progression of degenerative joint disease. Among these techniques, the suture fixation iliofemoral, has proven effective, with good recovery of patients. The purpose of this study was to evaluate the anchor titanium as the wire clamping method suture the ileum, thus replacing, in the iliofemoral fixation technique, the laborious ma-neuvering passage of suture material through a tunnel in iliac body. This technique was performed in 10 dogs of various races attended at UNESP Veterinary Hospital – Jaboticabal. The patients, in its entirety, victims of trampling presented with varying degrees of lameness and pain in the hip. In some cases, attempts occurred after reluxações closed reduction and forami these patients undergoing surgical fixation and reduction of the dislocation by modified iliofemoral suture. The patients were followed clinically and radiographically for varying periods between 30 to 90 days postopera-tively. He observed the load support member on average 3 days after the procedure and 10 days most patients do not limping. There were visualized on radiographic ex-amination, perimplante osteolysis, or the appearance of osteophytes or joint sclerosis. The ilium femoral suture, modified by the use of an anchor attached to the ilium, was efficient in the treatment of hip dislocation, not being observed dislocation recurrence. Additionally, the use of titanium anchor greatly facilitating the fixing of the wire ilium, significantly reducing surgical time.
622

Estudo do comportamento em fadiga da liga Ti30Ta após tratamento alcalino e térmico: aplicações biomédicas / Study of fatigue behavior of Ti30Ta alloy after alkaline and heat treatment: biomedical applications

Silva, Kerolene Barboza da [UNESP] 01 August 2017 (has links)
Submitted by Kerolene Barboza da Silva null (kerolene.barboza@gmail.com) on 2017-08-31T17:34:00Z No. of bitstreams: 1 Dissertação Kerolene Barboza da Silva.pdf: 2059319 bytes, checksum: bf04b9b8bef053ca161ff152aa1e7550 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-09-01T14:32:47Z (GMT) No. of bitstreams: 1 silva_kb_me_guara.pdf: 2059319 bytes, checksum: bf04b9b8bef053ca161ff152aa1e7550 (MD5) / Made available in DSpace on 2017-09-01T14:32:47Z (GMT). No. of bitstreams: 1 silva_kb_me_guara.pdf: 2059319 bytes, checksum: bf04b9b8bef053ca161ff152aa1e7550 (MD5) Previous issue date: 2017-08-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Titânio e suas ligas são considerados muito importantes na área médica devido a sua excelente biocompatibilidade e propriedades mecânicas. Nos últimos anos as superfícies dos implantes têm sido estudadas com o objetivo de melhorar suas respostas ósseas, levando há uma tendência de provocar alterações superficiais a fim de acelerar o processo de osseointegração. O tratamento alcalino e térmico é um método típico de modificação da superfície responsável pelo surgimento de uma camada microporosa de óxidos bioativos. No entanto, é importante lembrar que os implantes trabalham sob a ação de carregamentos mecânicos complexos e que, em várias situações, é bastante comum a ocorrência de falhas por fadiga. Visto que, a superfície do implante está sujeita a maiores solicitações que qualquer outra parte, suas características são muito importantes. O objetivo principal da presente pesquisa é estudar a influência da alteração de superfície, por meio da realização do tratamento alcalino e térmico, no comportamento em fadiga da liga Ti30Ta. O trabalho foi iniciado com a fusão dos elementos da liga em forno a arco voltaico em atmosfera de argônio, seguido de tratamento térmico e forjamento rotativo. Para o estudo de fadiga foram confeccionados corpos de provas padrão. A modificação da superfície foi realizada por meio do tratamento alcalino empregando-se solução de NaOH 1,5 M e tratamento térmico. Posteriormente, os corpos de prova foram ensaiados em fadiga. A caracterização utilizou técnicas de microscopia óptica, microscopia eletrônica de varredura, difração de raios X, rugosidade e ângulo de contato. Os resultados obtidos sugerem que a modificação da superfície, dentro das condições realizadas neste estudo, não influenciou no desempenho mecânico da liga Ti30Ta. / Titanium and its alloys are considered very important in the medical area because their excellent biocompatibility and mechanical properties. In recent years surfaces implant have been studied with the goal of improving their bone answers, leading to a tendency to cause superficial changes through the action of chemicals products in order to accelerate the osseointegration process. Alkaline and heat treatment is a typical method of surface modification by surface deposition of bioactive oxides with a porous surface. However it is important to remember that the implants work under the action of complex mechanical loads and the occurrence of failures due to fatigue is quite common in many situations. Since the surface implant is subject to greater demands than any other part, its characteristics are very important. The main goal of this research is to study the influence of modification surface on the fatigue behavior of the Ti30Ta alloy. This work was started with the experimental alloy obtained by melting of the elements in a voltaic arc furnace, heat treatment and cold work. For the fatigue study were prepared specimens. The surface modification was carried out by alkaline treatment using NaOH solution 1,5 M and heat treatment. Later, the specimens were tested in fatigue. The characterization was performed using optical microscopy, scanning electron microscopy, X - ray diffraction, roughness and contact angle. The results obtained suggested that surface modification didn’t affected the Ti30Ta alloy mechanical performance.
623

Avaliação da resistência ao desgaste do metal de solda GTAW reforçado por carbonetos de titânio / Evaluation of wear resistance of GTAW weld metal reinforced by titanium carbides

Egito, Guilherme de Marco Pessôa do [UNESP] 28 July 2017 (has links)
Submitted by GUILHERME DE MARCO PESSÔA DO EGITO null (guilhermempegito@gmail.com) on 2017-09-25T23:54:02Z No. of bitstreams: 1 Guilherme de M. P. do Egito.pdf: 3224395 bytes, checksum: b0a5e722d16c8838ccf9facdd1564c83 (MD5) / Approved for entry into archive by Monique Sasaki (sayumi_sasaki@hotmail.com) on 2017-09-27T20:46:58Z (GMT) No. of bitstreams: 1 egito_gmp_me_ilha.pdf: 3224395 bytes, checksum: b0a5e722d16c8838ccf9facdd1564c83 (MD5) / Made available in DSpace on 2017-09-27T20:46:58Z (GMT). No. of bitstreams: 1 egito_gmp_me_ilha.pdf: 3224395 bytes, checksum: b0a5e722d16c8838ccf9facdd1564c83 (MD5) Previous issue date: 2017-07-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Setores industriais, como o sucroalcooleiro e a mineração, sofrem com a grande perda de eficiência ou até a parada de seus equipamentos causada pelo desgaste abrasivo. Para que essas paradas sejam reduzidas utiliza-se de técnicas para aumentar a vida útil das peças como revestimentos duros. Os revestimentos mais comuns empregados nesses reparos são compostos de altos teores de cromo e carbono aplicados por soldagem. O presente trabalho foi analisado o comportamento ao desgaste de metal de solda endurecido por carbonetos de titânio, formados a partir de uma mistura de cavacos das ligas ASTM F67 e ASTM F136 após solda pelo processo de soldagem ao arco tungstênio em atmosfera gasosa, SATG (Gas Tungsten Arc Welding – GTAW) em uma base de aço ASTM A36. A resistência ao desgaste foi avaliada por ensaios de microabrasão, nos quais foi empregado um microabrasômetro de esfera fixa (ISO 26424). Houve uma massiva formação de carbonetos de titânio (TiC) na matriz ferrosa, reforçada pela presença de carbonetos finos. O coeficiente de desgaste para um baixo carregamento apresentou um crescimento constante enquanto para uma alta carga e distância de deslizamento apresentou um patamar de estabilização, sendo o melhor resultado apresentado pelo cordão solda ASTM F 136 de alta energia. / Industrial sectors, such as sugar/alcohol and mining, suffer with a large loss of efficiency or malfunction of the equipments caused by abrasive wear. For these shutdowns are reduced use of techniques to extend the life of parts, such as hard coatings. The most common coatings used in these repairs are compounds high levels of chromium and carbon applied by welding. The presente work aimed the wear behavior of a weld metal hardened by titanium carbides was analyzed, produce from a mixture of chips of alloys ASTM F 67 and ASTM F 136 after welded by Gas Tungsten Arc Welding (GTAW) on a steel base ASTM A 36. The wear resistence was evaluated by micro abrasive wear test, in which it was employed a ball cratering test. There was a massive formation of titanium carbides (TiC) in the ferrous matrix, reinforced by the presence of fine carbides. The wear rates to low load showed constant growth. while to high load and slip distance showed a stabilization level, the best result using high heat input welding of ASTM F 136 titanium alloy.
624

Influência do zircônio e do oxigênio na estrutura, microestrutura e propriedades mecânicas de ligas do sistema Ti-Mo-Zr / Influence of zirconium and oxygen on the structure, microstructure and mechanical properties of alloys of the Ti-Mo-Zr system

Araújo, Raul Oliveira de [UNESP] 28 August 2017 (has links)
Submitted by Raul Oliveira de Araújo null (raularaujo@fc.unesp.br) on 2017-10-10T19:42:30Z No. of bitstreams: 1 tese_raul.pdf: 7762011 bytes, checksum: 32b91174837e108414bbaeb48b968932 (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-10-11T18:18:16Z (GMT) No. of bitstreams: 1 araujo_ro_dr_bauru.pdf: 7762011 bytes, checksum: 32b91174837e108414bbaeb48b968932 (MD5) / Made available in DSpace on 2017-10-11T18:18:16Z (GMT). No. of bitstreams: 1 araujo_ro_dr_bauru.pdf: 7762011 bytes, checksum: 32b91174837e108414bbaeb48b968932 (MD5) Previous issue date: 2017-08-28 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Devido a uma série de fatores como o número de acidentes nos esportes, trânsito, doenças como artrite, artrose e osteoporose, a perda das funções biológicas em função do envelhecimento entre outros, acarretam a procura por materiais com a capacidade de cumprir a função de substituir partes ou funções orgânicas do corpo humano. Entre os materiais com a função de substituir tecidos humanos que suportam cargas, estão a classe dos metais, dentre esta classe destacam-se as ligas de Co-Cr, o aço ASTM F138, o titânio puro e a liga Ti-6Al-4V. Porém há a necessidade de ligas que promovam uma melhor compatibilidade mecânica e biológica. Este trabalho visa a preparação e caracterização das ligas Ti-10Mo-xZr (x = 5, 10, 15 e 20 %p), para aplicações como biomaterial. Estas ligas foram submetidas a tratamentos termomecânicos, de laminação à quente, tratamento térmico de recozimento, tratamento térmico de solubilização e tratamento térmicos em atmosfera controlada de oxigênio, para a incorporação deste elemento na liga. As ligas foram caracterizadas quimicamente por espectroscopia de emissão óptica com plasma acoplado indutivamente (ICP-OES), espectroscopia de dispersão de energia (EDS), além de análises de gases e de densidade; caracterizações estruturais e microestruturais por medidas de difração de raios X, refinamento dos difratogramas pelo método de Rietveld, microscopias óptica e eletrônica de varredura; caracterizações mecânicas por microdureza Vickers e módulo de elasticidade e caracterização biológica por ensaios de citotoxicidade in vitro. As ligas apresentaram a estequiometria prevista e boa homogeneidade química. Com relação a estrutura e microestrutura houve a predominância da fase beta a qual aumentou a estabilidade com a concentração de zircônio em detrimento de outras fases como alfa, alfa’’ e ômega. A microdureza diminuiu com o acréscimo do percentual de zircônio (de 451 HV para 372 HV), devido a uma maior estabilidade da fase beta em detrimento das fases secundárias. O mesmo comportamento é verificado em relação ao módulo de elasticidade (de 98 GPa para 77 GPa). Com relação a influência do oxigênio houve aumento na microdureza e módulo de elasticidade com o acréscimo deste elemento. Os testes biológicos não indicaram efeitos citotóxicos. Em se tratando de aplicações biológicas a liga Ti-10Mo-20Zr torna-se a mais promissora por possuir menor módulo de elasticidade em comparação com o aço ASTM F138, Co-Cr, Ti-cp, Ti-6Al-4V e Ti-15Mo. / Due to several factors such as the number of accidents in sports, traffic, diseases like arthritis, osteoporosis, and the loss of biological functions related to aging, among others, lead to a search for materials with the ability to fulfill the function of replacing parts or organic functions of the human body. Among the materials with the function of replacing human tissues that load-bearing, are the class of metals, and among this class are the Co-Cr alloys, the ASTM F138 stainless steel, the pure titanium and the Ti-6Al-4V alloy. However, there is a need for alloys that promote better mechanical and biological compatibility. In this sense, this work aims at the preparation and characterization of the Ti-10Mo-xZr alloys (x = 5, 10, 15 and 20 wt%) for biomaterial applications. These alloys were subjected to several kinds of thermomechanical treatments, such as hot rolling, annealing, solubilization and heat treatment in an oxygen controlled atmosphere, in order to incorporate this element into the alloy. The alloys were chemically characterized by inductively coupled plasma optical emission spectroscopy (ICP-OES), energy dispersive spectroscopy (EDS), in addition to gas and density analyzes. Structural and microstructural characterization were made by X-ray diffraction measurements, with refinement by Rietveld’s method, optical and scanning electron microscopy. Mechanical characterization was made by Vickers microhardness and elastic modulus measurements, and biological characterization was made by in vitro cytotoxicity assays. The alloys presented desirable stoichiometry with good chemical homogeneity. Regarding to structure and microstructure, there is a predominance of  phase, which becomes more stable with the increase in zirconium concentration in detriment of other phases as ’, ’’ and . In this way, the microhardness decreases with the addition of the substitutional element (from 451 HV to 372 HV), due to a higher  phase stability, in detriment of those secondary phases. The same behavior was verified in relation to the elastic modulus (from 98 GPa to 77 GPa). With respect to the influence of oxygen, there is an increase in the values of microhardness and elastic modulus with the addition of this element. Biological tests did not indicate cytotoxic effects. For biological applications, the Ti-10Mo-20Zr alloy becomes the most promising because it has a low astic modulus compared to ASTM F138 stainless steel, Co-Cr, cp-Ti, Ti-6Al-4V and Ti-15Mo alloy. / FAPESP: 2013/09063-5
625

Projeto e fabricação de um reator para tratamento superficial de implantes por oxidação eletrolítica a plasma

Nascimento Neto, Arlindo Balbino do 13 December 2017 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-04-11T20:54:51Z No. of bitstreams: 1 ArlindoBalbinoDoNascimentoNeto_TESE.pdf: 17361179 bytes, checksum: 6648d2a7b9ce65ae1f54a644cf1af237 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-04-16T22:32:13Z (GMT) No. of bitstreams: 1 ArlindoBalbinoDoNascimentoNeto_TESE.pdf: 17361179 bytes, checksum: 6648d2a7b9ce65ae1f54a644cf1af237 (MD5) / Made available in DSpace on 2018-04-16T22:32:13Z (GMT). No. of bitstreams: 1 ArlindoBalbinoDoNascimentoNeto_TESE.pdf: 17361179 bytes, checksum: 6648d2a7b9ce65ae1f54a644cf1af237 (MD5) Previous issue date: 2017-12-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Até a presente data muitos estudos têm sido realizados em busca de materiais biocompatíveis para a fabricação de implantes, principalmente na área ortopédica e odontológica. Nesse sentido as ligas de titânio desempenham um papel importante para o uso em implantes devido à sua baixa densidade, não toxicidade, resistência à corrosão e biocompatibilidade. O titânio puro na presença dos fluidos biológicos apresenta uma fina camada passiva de óxido responsável pela biocompatibilidade quando inserido no organismo. No entanto, esta camada de óxido espontânea pode ser perdida, rapidamente, se inserido em ambientes adversos. Consequentemente, a modificação superficial apropriada se faz necessária para as ligas a base de titânio, melhorando as propriedades de superfície e sua bioatividade. Existe um grande espectro de técnicas de modificação de superfície disponíveis, tais como deposição física de vapor, deposição química a vapor, anodização, pulverização de plasma e Oxidação Eletrolítica por Plasma (PEO). Entre essas técnicas, o PEO apresenta-se como uma técnica atrativa para aplicações biomédicas devido as suas características que favorecem a osseointegração. Contudo, não se conhece as características e viabilidade da produção de revestimentos realizados em amostras cilíndricas, quando esses são produzidos em quantidade dentro da mesma solução eletrolítica. Portanto, faz-se necessário um estudo e melhor compreensão dos aspectos fundamentais desta tecnologia sob essa condição. Isso pode avançar a compreensão científica do processo PEO, o que poderia permitir um melhor uso da técnica para aplicações em larga produção. Baseado no que foi exposto, realizou-se revestimentos em banho eletrolítico por 1, 8 e 16 minutos, respectivamente, com tensão de 290 V CC. Realizou-se os tempos citados acima para 1, 2 e 3 amostras submersa simultaneamente na mesma solução eletrolítica. Para caracterizar a espessura do revestimento das amostras foram utilizados as técnicas de Microscopia Ótica (MO) e Eletrônica de varredura (MEV). Para obter a composição química e fase do revestimento, foram utilizados as técnicas de caracterização de Espectroscopia de Energia Dispersiva (EED), Difratometria de Raio-X (DRX). Com o objetivo de identificar a porosidade superficial utilizou-se o rugosímetro, o MEV e o método da figura de Lissajous. Para análise de desgaste no revestimento foi utilizado o método tribológico pino sobre haste. No estudo da molhabilidade utilizou-se o método da gota séssil. Os resultados obtidos foram revestimentos homogêneos, porosos, hidrofílicos e com resistência mecânica ao contato. Através do método da figura de Lissajous pode ser determinado o nível de porosidade presente nos revestimentos PEO. Os resultados obtidos mostraram a capacidade de escalabilidade de produção com características que demonstram ser favoráveis para se ter uma osseointegração homogênea e estável para implantes. / To date, many studies have been carried out in search of biocompatible materials for the manufacture of implants, mainly in the orthopedic and dental area. In this sense, titanium alloys play an important role for use in implants because of their low density, non-toxicity, corrosion resistance and biocompatibility. Pure titanium in the presence of biological fluids has a thin passive layer of oxide responsible for biocompatibility when inserted into the body. However, this spontaneous oxide layer can be lost, quickly, if inserted in adverse environments. Accordingly, appropriate surface modification is required for titanium based alloys, improving the surface properties and their bioactivity. There is a wide spectrum of surface modification techniques available, such as physical vapor deposition, chemical vapor deposition, anodizing, plasma spraying and Plasma Electrolytic Oxidation (PEO). Among these techniques, PEO is an attractive technique for biomedical applications because of its characteristics that favor osseointegration. However, the characteristics and feasibility of producing coatings made on cylindrical samples are not known when they are produced in quantity within the same electrolytic solution. Therefore, it is necessary to study and better understand the fundamental aspects of this technology under this condition. This may advance the scientific understanding of the PEO process, which could allow a better use of the technique for large-scale applications. Based on the above, electrolytic coatings were made for 1, 8 and 16 minutes, respectively, with a voltage of 290 VDC. The times mentioned above were performed for 1, 2 and 3 samples submerged simultaneously in the same electrolytic solution. To characterize the coating thickness of the samples, the techniques of Optical Microscopy (MO) and Scanning Electron (SEM) were used. To obtain the chemical composition and phase of the coating, the characterization techniques of Dispersive Energy Spectroscopy (EED), X-ray Diffraction (XRD) were used. In order to identify the surface porosity, the rugosimeter, the SEM and the Lissajous figure method were used. For the analysis of wear on the coating, the tribological method was used. In the study of wettability, the sessile drop method was used. The results were homogeneous, porous, hydrophilic and with mechanical resistance to contact. By the Lissajous figure method the level of porosity present in the PEO coatings can be determined. The results showed the capacity of production scalability with characteristics that prove to be favorable to have a homogeneous and stable osseointegration for implants.
626

Projeto de prótese de disco intervertebral de Ti-6Al-4V entre L4/L3 / Intervertebral disc prosthesis project of Ti-6Al-4V between L4/L3

Colman, Bruno Fontoura da Silva 05 March 2018 (has links)
Submitted by BRUNO FONTOURA DA SILVA COLMAN (brunocolman@hotmail.com) on 2018-05-03T15:19:22Z No. of bitstreams: 1 Dissertação de Mestrado - Bruno Colman Rev.36_03-05-2018.pdf: 5215084 bytes, checksum: 2152650458ee3ee274744cb5b222bb3c (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-05-03T17:05:09Z (GMT) No. of bitstreams: 1 colman_bfs_me_ilha.pdf: 5215084 bytes, checksum: 2152650458ee3ee274744cb5b222bb3c (MD5) / Made available in DSpace on 2018-05-03T17:05:09Z (GMT). No. of bitstreams: 1 colman_bfs_me_ilha.pdf: 5215084 bytes, checksum: 2152650458ee3ee274744cb5b222bb3c (MD5) Previous issue date: 2018-03-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esse trabalho tem a finalidade de projetar, com base em levantamento bibliográfico, uma prótese de disco intervertebral de Ti6Al4V pelo processo DMLS. Os sistemas de imagem de tomografias computadorizadas e ressonâncias magnéticas trabalham de maneira semelhante. Imagens em 3D de dados dos pacientes são construídas através da combinação de fatias 2D tomadas a partir de sistemas de sensores e da interpolação entre eles. A distância entre as fatias desses sistemas de imagens é grosseira comparada com a tecnologia da manufatura aditiva, portanto, esses processos combinam as imagens das fatias dentro de um software para criar um modelo 3D sobrepondo camadas, devido a essa sinergia entre os dois tipos de sistema, pesquisadores de todo o mundo tentam melhorar e inventar próteses para substituir o disco intervertebral através da ciência. Os resultados mostraram que a fabricação de uma prótese de disco com junta esférica pelo processo de manufatura aditiva é viável, porém nos segmentos menores, como na cervical ainda são difíceis de produzir devido à altura do disco intervertebral e ao limite da dimensão das camadas da manufatura aditiva, que atualmente estão por volta dos 20μm, por isso requerem tratamentos superficiais após sua fabricação. Espera-se que este trabalho possa ajudar futuros pesquisadores da área de biomecânica da coluna vertebral. / This work has the purpose of designing, based on a bibliographical survey, an intervertebral disc prosthesis of Ti6Al4V by the DMLS process. Computed tomography (CT) imaging systems and MRIs work similarly. 3D images of patients data are constructed by combining 2D slices taken from sensor systems and interpolating between them. The distance between the slices of these imaging systems is rough compared to the additive manufacturing technology, so these processes combine the slice images within a software to create a 3D model overlapping layers because of this synergy between the two system types, researchers around the world try to improve and devise prostheses to replace the intervertebral disc through science. The results showed that the manufacture of a disc prosthesis with spherical joint by the additive manufacturing process is feasible, but in the smaller segments, such as in the cervical still difficult to produce due to the height of the intervertebral disc and to the limit of the size of the layers of the manufacture additives, which are currently around 20μm, so they require surface treatments after their manufacture. It is hoped that this work may help future researchers in the area of spinal biomechanics. / CAPES - PROPG
627

Funcionalização da liga Ti15Zr15Mo após crescimento de nanotubos de TiO2 com recobrimento de quitosana, ácido hialurônico e partículas de ZnO para aplicações biomédicas / Functionalization of the TiO2 nanotube growth in a Ti15Zr15Mo alloy with coating of chitosan, hyaluronic acid and ZnO particles for biomedical applications

Konatu, Reginaldo Toshihiro [UNESP] 06 March 2018 (has links)
Submitted by Reginaldo Toshihiro Konatu (rtkonatu@gmail.com) on 2018-05-03T17:15:41Z No. of bitstreams: 1 Tese KONATU 2018.pdf: 3998865 bytes, checksum: 9ed8e8c75039aad725b37cff903fad84 (MD5) / Rejected by Pamella Benevides Gonçalves null (pamella@feg.unesp.br), reason: Solicitamos que realize correções na submissão seguindo as orientações abaixo: Você realizou duas submissões favor desconsiderar esta. Agradecemos a compreensão. on 2018-05-04T17:53:18Z (GMT) / Submitted by Reginaldo Toshihiro Konatu (rtkonatu@gmail.com) on 2018-05-04T18:50:12Z No. of bitstreams: 1 Tese Konatu 2018.pdf: 4232195 bytes, checksum: e32103c38cfbff0ac3d36adba585b7ad (MD5) / Approved for entry into archive by Pamella Benevides Gonçalves null (pamella@feg.unesp.br) on 2018-05-04T19:25:28Z (GMT) No. of bitstreams: 1 konatu_rt_dr_guara.pdf: 4232195 bytes, checksum: e32103c38cfbff0ac3d36adba585b7ad (MD5) / Made available in DSpace on 2018-05-04T19:25:28Z (GMT). No. of bitstreams: 1 konatu_rt_dr_guara.pdf: 4232195 bytes, checksum: e32103c38cfbff0ac3d36adba585b7ad (MD5) Previous issue date: 2018-03-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente trabalho tem como objetivo a obtenção de revestimentos poliméricos bactericidas formados por ácido hialurônico/quitosana/ZnO na superfície da liga Ti15Zr15Mo após crescimento de nanotubos de TiO2 empregando oxidação anódica. A liga Ti15Zr15Mo foi processada em forno a arco voltaico com atmosfera controlada e tratados termicamente. Os nanotubos de TiO2 foram obtidos por meio de oxidação anódica. Para obtenção dos revestimentos, as amostras foram recobertas com camadas de ácido hialurônico/quitosana/ZnO. As superfícies foram avaliadas empregando microscopia eletrônica de varredura (MEV), analise por difração de raios-X (DRX), espectroscopia de fotoelétrons excitados por raios-X (XPS) e ângulo de contato. A condição ideal para obtenção dos nanotubos ordenados de TiO2 na superfície da liga foi 30V, eletrólito formado por glicerol, água deionizada (1:1 em volume) e fluoreto de amônio (2,7 g/L) e tempo de 24 horas. Para esses parâmetros, os nanotubos formados apresentaram diâmetro médio de 130 nm e espessura de 1290 nm. O revestimento polimérico escolhido foi de 2 bicamadas de ácido hialurônico/quitosana contendo partículas de ZnO. Os estudos in vitro realizados para avaliar adesão bacteriana de Staphylococcus aureus mostraram que não houve diferença significativa entre as amostras com e sem recobrimento. / Nowadays the development of new materials for biomedical application has become of extreme importance due to the need of new materials with excellent mechanical properties, physicochemical and biocompatibility for use in the manufacture of biomedical devices. In addition to the material presenting the necessary bulk properties, it is of utmost importance that they present a response from the host to the implant. For this, the surface of the material must have characteristics that can be obtained with superficial treatments. This work aims at the analysis of the surface of nanotubes grown on the Ti15zr15Mo alloy functionalized with thin film of hyaluronic acid, chitosan and ZnO nanoparticles. The surface was analyzed by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and contact angle. The nanotubes formed had a mean diameter of 130 nm and a thickness of 1290 nm. The coating with the polymeric bilayers, with a number of more than 4 bilayers, closed the nanotubes and increased the contact angle, being used 2 biacamadas for the incorporation of ZnO. The concentration of the ZnO solution was very low for incorporation and bactericidal effect.
628

Tratamento de superfície por oxidação à plasma eletrolítico para viabilizar o uso de implantes biomédicos: da Telessaúde para o SUS / Surface treatment by plasma electrolytic oxidation to viabilize the use of biomedical implants: from Telessaúde to SUS

Paiva, Ana Karenina de Oliveira 23 March 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-05-03T22:29:48Z No. of bitstreams: 1 AnaKareninaDeOliveiraPaiva_DISSERT.pdf: 827570 bytes, checksum: 54cd7a519a5117b82729598fcbd25a05 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-05-14T20:48:58Z (GMT) No. of bitstreams: 1 AnaKareninaDeOliveiraPaiva_DISSERT.pdf: 827570 bytes, checksum: 54cd7a519a5117b82729598fcbd25a05 (MD5) / Made available in DSpace on 2018-05-14T20:48:58Z (GMT). No. of bitstreams: 1 AnaKareninaDeOliveiraPaiva_DISSERT.pdf: 827570 bytes, checksum: 54cd7a519a5117b82729598fcbd25a05 (MD5) Previous issue date: 2018-03-23 / Com base nos princípios constitucionais de integralidade e equidade, tornou-se necessário viabilizar a incorporação dos procedimentos ortodônticos e implante dentário pelo setor público de saúde. Um estudo realizado pelo Ministério da Saúde verificou a redução no componente cariado de 35%, a redução desse índice viabilizou a introdução desses implantes no Sistema Único de Saúde (SUS). Apesar da implementação para no máximo 6 implantes por paciente nos centros de especialidades odontológicas, o custo do tratamento superficial de implantes ainda é elevado e impacta no preço final para indústria. Com o objetivo de resolver esse problema, foi utilizado o método de tratamento de superfície de Oxidação por Plasma Eletrolítico (PEO). Tratou-se 18 cilindros de titânio grau II, com 3 mm de diâmetro e 25 mm de comprimento. O tempo de tratamento utilizado foi de 1, 8 e 16 minutos. A solução eletrolítica estava na temperatura ambiente e a tensão aplicada foi de 290 V. Após os tratamentos, as amostras foram caracterizadas por Fluorescência de Raios-X (FRX), Microscopia Ótica (MO), Microscopia Eletrônica de Varredura (MEV) e por Espectroscopia de Raios-X e Energia Dispersiva (EDS). Em seguida foi feito Microscopia de Força Atômica (AFM) para caracterização da textura superficial. Identificou-se neste trabalho através das análises químicas pela Fluorescência de Raios-X a presença do TiO2 na superfície da amostra. Verificou-se no MEV que os revestimentos exibem uma característica porosa, apresentando uma interface bem aderida e sem presença de espaços vazios. Nas imagens do AFM observou-se que com o aumento do tempo de tratamento houve uma maior rugosidade e aumento da homogeneidade da distribuição dos cristais cerâmicos na superfície. Nos ensaios de molhabilidade apresentaram um ângulo de molhamento menor para as amostras com o tratamento por PEO com tempo de 1 e 8 minutos. Conclui-se que a técnica por Oxidação por Plasma Eletrolítico mostrou-se eficaz na deposição de um revestimento cerâmico, melhorando a qualidade da superfície reduzindo o custo do tratamento superficial, diminuindo o valor final do implante para implementação no SUS. / Based on the constitutional principles of integrality and equity, it became necessary to enable the incorporation of orthodontic procedures and dental implant by the public health sector. A study carried out by the Ministry of Health verified the reduction in the caries component of 35%, the reduction of this index made possible the introduction of these implants in the Unified Health System (Sistema Único de Saúde - SUS). Despite the implementation for a maximum of 6 implants per patient in dental specialty centers, the cost of surface treatment of implants is still high and impacts on the final price for the industry. In order to solve this problem, the surface treatment method of Plasma Electrolytic Oxidation (PEO) was used. They were treated with 18 cylinders of grade II titanium, 3 mm in diameter and 25 mm in length. The treatment time was 1, 8 and 16 minutes. After the treatments, the samples were characterized by X-Ray Fluorescence (FRX), Optical Microscopy (OM), Scanning Electron Microscopy (SEM) and Spectroscopy of X-rays and Dispersive Energy (ESD). Afterwards, it was made Atomic Force Microscopy (AFM) to characterize the surface texture. The presence of TiO2 on the surface of the sample was identified by X-Ray Fluorescence in this work. It was verified in the SEM that the coatings exhibit a porous characteristic, presenting an interface well adhered and without presence of empty spaces. In the images of the AFM, it was observed that with the increase of the treatment time there was a greater roughness and increase of the homogeneity of the distribution of the ceramic crystals in the surface. In the wettability tests they presented a lower wetting angle for the samples with PEO treatment with time of 1 and 8 minutes. It is concluded that the Plasma Electrolytic Oxidation technique proved to be effective in the deposition of a ceramic coating, improving the quality of the surface reducing the cost of surface treatment, reducing the final value of the implant for implementation in the SUS.
629

Caracterização química e morfológica de implantes Ti-Mo com superfícies usinadas e modificadas por feixe de laser : análises biomecânica, histológica e histométrica em coelhos /

Guastaldi, Fernando Pozzi Semeghini. January 2010 (has links)
Orientador: Eduardo Hochuli Vieira / Banca: Osvaldo Magro Filho / Banca: Adalberto Luiz Rosa / Resumo: Proposição: Caracterizar, química e morfologicamente, superfícies de implantes constituídos de ligas de titânio/molibidênio (Ti-15Mo), modificadas por feixe de laser, comparando-as com implantes da mesma liga com superfície usinada, empregando-se análises biomecânica, histológica e histométrica. Material e método: Dezesseis coelhos receberam 1 implante por tíbia das seguintes superfícies: superfície usinada (SU) e superfície modificada por laser (SML). Após 8 semanas foi realizado o teste biomecânico em 6 animais. As amostras teciduais dos outros 10 animais foram submetidas à análise histológica e histométrica da interface osso-implante. As superfícies dos implantes foram analisadas por MEV e EDS, antes da realização do procedimento cirúrgico. Resultado: A caracterização da superfície mostrou uma topografia rugosa, regular e homogênea, promovida pela irradiação por laser. A análise por EDS mostrou ausência de contaminação da superfície pelo método de modificação. O resultado na remoção por torque, no período, foi 51,5 N.cm para SU e > 90 N.cm para SML. A análise histológica mostrou formação e um íntimo contato do tecido ósseo em 42% da superfície do implante SML, o que não foi constatado no implante SU (24%). Dados histométricos (BIC%) mostraram diferenças estatisticamente significativas entre o grupo SU e o SML, para o implante inteiro (p = 0.0012), as 3 melhores espiras consecutivas da região cortical (p = 0.0012) e o espaço medular (p = 0.0082). Conclusão: O tratamento a laser é um procedimento limpo, reprodutível e promove características físico-químicas e topográficas, importantes para a osseointegração. Os implantes de Ti-15Mo com SML apresentaram resultados biomecânicos, histológicos e histométricos superiores aos usinados / Abstract: Purpose: Characterize, chemically and morphologically, implants surfaces of titanium/molybdenum alloy (Ti-15Mo), modified by laser beam, and comparing them with the same alloy implants with machined surface, using biomechanical, histological and histometric analysis. Material and method: Sixteen rabbits received 1 implant by tibia of the following surfaces: machined surface (MS) and laser-modified surface (LMS). After 8 weeks a biomechanical test was performed in 6 animals. The tissue samples of the other 10 animals were submitted to histological and histometric analysis of bone-implant contact. The surfaces of the implants were analyzed by SEM and EDX prior to the surgical procedures. Result: The characterization of the surface showed a rough, regular and homogeneous topography, caused by laser irradiation. The EDX analysis showed no contamination of the surface by the method of modification. Average removal torque in the period was 51.5 N.cm for MS and > 90 N.cm for LMS. Histological analysis showed bone formation and close contact of bone tissue on 42% of the LMS implant surface, which was not observed in the MS implants (24%). Histometric data (BIC%) showed statistically significant differences between the control and test group for the entire implant (p = 0.0012), the 3 best consecutive spires of the cortical (p = 0.0012) and medullary area (p = 0.0082). Conclusion: The laser treatment is a clean, reproducible procedure, and promotes important physico-chemical and topographic characteristics for osseointegration. The Ti-15Mo implants with LMS showed better biomechanical, histological and histometric results than the machined ones / Mestre
630

Instrumento cortador e removedor de material edodôntico: desenvolvimento e aplicabilidade /

Gomes, Cristiane Andrade. January 2010 (has links)
Resumo: A proposta do presente estudo foi a de desenvolver e viabilizar a elaboração de um instrumento endodôntico para facilitar e minimizar os riscos causados pela técnica utilizada pelos dentistas durante a finalização do tratamento do canal radicular (endodôntico). Analisando o procedimento utilizado atualmente para o corte e a remoção do excesso de material endodôntico, os chamados cones de guta percha, julga-se apropriado o desenvolvimento de um instrumento inovador para executar esta tarefa. Esta necessidade se deve ao fato de não existir no mercado odontológico um instrumento específico para tal finalidade. Atualmente, os dentistas utilizam uma espátula metálica em aço inoxidável aquecida em chama para o corte do excesso do cone endodôntico, sendo que esta espátula (os chamados condensadores Paiva) atinge temperaturas elevadas, aproximadamente 230◦ C, podendo causar trauma na cavidade oral. O presente trabalho se propõe ainda a avaliar a efetividade das ponteiras metálicas do instrumento, quanto ao seu uso e ciclos de esterilização em autoclave. Os materiais utilizados para confecção das ponteiras e utilizados para os ensaios mecânicos serão: o aço inoxidável 304 L e o titânio Grau 2. Para que o excesso de guta percha seja removido do canal radicular será necessária a confecção de diferentes diâmetros de ponteiras em titânio ou aço inoxidável 304 L, que serão conectadas a extremidade do instrumento elétrico e posteriormente aquecidas. Ensaios mecânicos de fadiga axial foram realizados em 16 corpos de prova: 8 em titânio e 8 em aço inoxidável 304 L, segundo norma ASTM E8. A metade da amostra foi submetida a quinze ciclos de esterilização em autoclave. Pode-se observar que o aço inoxidável 304 L apresentou resistência à fadiga superior ao do Titânio Grau 2. Após os ensaios de fadiga, definiu-se que o material utilizado... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to develop the preparation of an endodontic instrument to facilitate and minimize the risks caused by the technique used by dentists during the root canal treatment completion (endodontic). Analyzing the current procedure for cutting and removal of excess endodontic material (gutta-percha), it is deemed appropriate the development of an innovative tool. The necessity is due to the fact that there is no specific instrument in dentistry for such purpose. Currently, dentists use a heated stainless steel spatula for cutting the excess part of the endodontic cone and this spatula reaches high temperatures (around 230 ◦ C) that may cause oral cavity trauma. Given the above, this work aims to develop an electric instrument for cutting and removing the excess of gutta-percha after root canal treatment thereby optimizing the technique and minimizing the risks to the patient. This study also evaluates the effectiveness of the instrument metal tip on its use and sterilization cycles by autoclaving. The materials used for the manufacturing of the metal tips and mechanical tests are: 304 L stainless steel and Grade 2 titanium. The manufacturing of different diameters metal tips either of titanium or stainless steel (which are attached to the end of the electrical apparatus and then heated.) is required for the removal of the excess of gutta-percha from the root canal. Axial fatigue mechanical tests were performed which verified the materials fatigue behavior specimens were manufactured for the axial fatigue tests, originating 16 specimens: 8 in titanium and 8 in 304 L stainless steel, according to ASTM E8. Half of the samples were subjected to 15 cycles of autoclave sterilization. It was observed that 304 L stainless steel showed fatigue resistance superior to that of Grade 2 Titanium. The results showed that even after the heat treatment... (Complete abstract click electronic access below) / Orientador: Luiz Fernando Costa Nascimento / Coorientador: Ana Paula Risifni Alves Claro / Banca: João Alberto de Oliveira / Banca: Rogério Pinto Mota / Banca: Carlos Antonio Reis Pereira Batista / Banca: João Marcelo Ferreira de Medeiros / Doutor

Page generated in 0.033 seconds