• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 316
  • 4
  • 3
  • Tagged with
  • 330
  • 330
  • 209
  • 206
  • 57
  • 55
  • 45
  • 44
  • 43
  • 38
  • 38
  • 34
  • 33
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Influência do uso de polímeros sintéticos no desempenho da flotação por ar dissolvido aplicada no tratamento de água para abastecimento / Influence of synthetic polymer usage on the performance of dissolved air flotation applied to supply water

Sartori, Luci 14 August 1998 (has links)
O uso de polímeros sintéticos como auxiliares de floculação no tratamento de águas para abastecimento é uma prática que vem sendo bastante estimulada. Contudo o uso na floculação visando a flotação de águas para abastecimento tem sido pouco estudado. Neste trabalho, são apresentados os resultados de estudo da influência da aplicação de polímeros sintéticos como auxiliares de floculação na clarificação, por flotação, de água preparada com cor elevada (100 ± 9,0 uC) e baixa turbidez (6,80 ± 1,0 uT). Foram investigados três diferentes tipos de polímeros (catiônico, aniônico e não iônico), aplicados conjuntamente ao coagulante primário (sulfato de alumínio). Após a otimização da dosagem deste coagulante (40 mg/L), sem emprego de polímeros, foi estudado o desempenho da flotação diante a redução da dosagem de coagulante conjugado à aplicação de diferentes dosagens de polímeros. Também foram investigadas a influência do tempo decorrido após a mistura rápida para a adição do polímero, e do tempo e gradiente médio de velocidade na floculação para a flotação. Foram utilizadas duas unidades de flotação por ar dissolvido, uma em escala de laboratório (Flotateste) e outra em escala piloto (com escoamento contínuo). Após a adequação dos parâmetros de floculação, os ensaios obtidos com o flotateste mostraram que a aplicação de 0,25 mg/L de polímero não iônico permitiu a redução de 50% na dosagem de coagulante, sem queda significativa na eficiência de remoção de cor e turbidez (96% e 93% respectivamente). Por sua vez, o polímero catiônico, na dosagem de 0,25 mg/L, possibilitou redução de 70% na dosagem de sulfato de alumínio, com eficiência de remoção de cor e turbidez de 90%. A instalação piloto de flotação operando com TASap de 262 m3/m2d, e aplicação de polímeros, nas condições otimizadas com o flotateste, foi capaz de fornecer bons resultados de remoção de cor aparente (82% e cor no efluente de 18,6 uC) e de turbidez (80% com turbidez de 1,40 uT no efluente). Nos ensaios com a unidade piloto de flotação operando com TASap de 525 m3/m2d, com redução de 70% na dosagem de coagulante (aplicação de 0,25 mg/L de polímero catiônico), observou-se redução de até 79% na massa de Iodo gerada. / The usage of synthetic polymers as flocculation aids for the treatment of supply water is a practice which have been widely stimulated, however its usage in flocculation aiming supply water flocculation has been scarcely studied. This work presents the results of the study of the influence of synthetic polymer application as a flocculation aids for clarifying prepared water containing high levei of color (100 ± 9.0 CU) and low turbidity (6.80 ± 1.0 NTU) through flotation. Three different kinds of polymers were investigated - cationic, anionic and non-ionic - which were applied together with the primary cogulant (aluminium sulphate). After the optimization of this coagulant dosage (40 mg/L), without the utilization of polymers, it was studied the flotation performance by the reduction of the coagulant dosage together with the application of different polymer dosages. It was also studied the influence of the time after rapid mixing for the polymer addition, and of time and average velocity gradient and flotation. Two units of dissolved air flotation were used, a bench unit and a pilot plant unit (with continuous flow). After the flocculation parameters adequacy, the essays obtained with FLOTATESTE showed that the application of 0.5 mg/L of non-ionic polymer allowed a reduction of 50% on coagulant dosage, without meningful drops of the color and turbidity removal efficient (96% and 93% respectively). On the other hand, the cationic polymer, at 0.25 mg/L, enabled a 70% reduction on the aluminium sulphate dosage with color and turbidity removal efficiency of 90%. The plant flotation unit, operating under a flow rate of 262 m3/m2d and with polymer application, under conditions optimized by FLOTATESTE, was able to provide good results of colour removal (82% and effluent color of 18.6 CU) and turbicity removal (83% with turbicity of 1.23 NTU in the effluent). In the essays with the pilot plant flotation unit, operating under a flow rate of 525 m3/m2d after reduction of 70% on the coagulant dosage (application of 0,25 mg/L of cationic polymer) , an up to 79% reduction in mass of sludge generated was observed.
242

ANÁLISE QUÍMICA MULTI-ELEMENTAR DE AMOSTRAS DE ÁGUA TRATADA E ASPECTOS DE SAÚDE PÚBLICA DE MUNICÍPIOS DA MESORREGIÃO SUL DE GOIÁS

Barbosa, Aurélio de Melo 30 March 2009 (has links)
Made available in DSpace on 2016-08-10T10:55:44Z (GMT). No. of bitstreams: 1 Aurelio de Melo Barbosa.pdf: 8372928 bytes, checksum: 34ed59e6bd218f99a1d12f2d2abdaa9e (MD5) Previous issue date: 2009-03-30 / Water, essential for life, has a direct influence on health, quality of life and development of mankind. However, due to natural and human causes, water may suffer contamination from various species, especially for chemical elements. Thus, this paper appears the results of a study of multi-elemental chemical analysis of samples of treated water collected in Water Treatment Plants of twenty-two cities of South Region of Goias State. It was also exposes data on sanitation and hospital morbidity and mortality of the study area. It was found two geochemical associations (SO4-Cl-Zn-Mn and Ca-Sr-Mg), that were presented in maps of distribution of each element geochemistry. Also it was found anomalous concentrations above the maximum permitted values of nitrate in samples of Quirinópolis and Morrinhos, and lead in the sample of Cromínia, with possible impact on the morbidity and mortality of these municipalities. / A água, essencial para a vida, tem influência direta sobre a saúde, qualidade de vida e desenvolvimento do ser humano. Entretanto, devido a causas naturais e antrópicas, a água pode sofrer contaminação de várias espécies, especialmente por elementos químicos. Assim, realizou-se um estudo de análise química multielementar de amostras de água tratada colhidas em Estações de Tratamento de Água de vinte e dois municípios da Mesorregião Sul Goiano. Também foram coletados dados sobre saneamento básico e morbidade hospitalar e mortalidade da área de estudo. Como resultado foram encontradas duas associações geoquímicas (Cl-Zn-SO4-Mn e Ca-Sr-Mg), sendo apresentados os mapas de distribuição geoquímica de cada elemento. Também descobriu-se concentrações anômalas, acima dos Valores Máximos Permitidos, de nitrato nas amostras de Quirinópolis e Morrinhos, e de chumbo na amostra de Cromínia, com possível impacto sobre a morbimortalidade dos referidos municípios.
243

ANÁLISE DA EFICIÊNCIA DE REMOÇÃO DE FERRO E MANGANÊS DE ÁGUAS DE ABASTECIMENTO POR FILTRAÇÃO ADSORTIVA

Paz, Elaine Carvalho da 25 May 2016 (has links)
Made available in DSpace on 2017-07-20T13:41:58Z (GMT). No. of bitstreams: 1 Elaine Carvalho da Paz.pdf: 5913998 bytes, checksum: 3abfb310351a148f2f4495951bcca8d2 (MD5) Previous issue date: 2016-05-25 / The present study evaluates the iron removal efficiency (Fe), manganese (Mn), apparent color and turbidity, using adsorptive filtration compared with conventional filtration, using a natural Zeolite as layer second material in a pilot unit with constructive and operational typology similar to the rapid downward filter, gravity and double layer. As adsorbent material was selected Zeolite WATERCELL-ZF-0410®, commercially available Clinoptilotite from Cuba, for having physical characteristics similar to the anthracite coal. Morphological characterization assays were performed (FEG-SEM) and elemental (EDS), physical characteristics (particle size, density, effective size and uniformity coefficient), lixiviation and filtration on a pilot scale. Morphological characterization analysis, it was found that the zeolite under consideration has a high adsorption capacity, prone to adsorption iron, manganese and sulfur in the upper range anthracite coal. The physical characterization analysis, it was verified that this Zeolite is a uniform material and graduated, has physical similarity to the coal and anthracite can be used as filtering material of the layer second. Leaching analysis showed that, possibly, there will be no release above the maximum value allowed in CONAMA Resolution n. ° 357/2005, metals detected in the leached extract for a backwashing of filter using this material as media filter, as well as probably not occur detachment of these metals in the final disposal of this waste system. The filtration analysis on a pilot scale concluded that designing a filter with downward filtration, with depth action and double layer using the Zeolite WATERCEL-ZF-0410 on the layer second, is viable. The conception of treatment proposed, in the conditions, parameters and settings studied, has average efficiency: 100.00% for the removal of manganese; 96.17% for the removal of iron; 99.90% for the removal of apparent color; and 98.96% for the removal of turbidity. / O presente trabalho avalia a eficiência de remoção de ferro (Fe), manganês (Mn), cor aparente e turbidez, utilizando a filtração adsortiva em relação à filtração convencional, com utilização uma Zeólita natural como material de segunda camada, em uma unidade piloto com tipologia construtiva e operacional semelhante de um filtro rápido descendente e a gravidade. Como material adsorvente foi selecionado a Zeólita WATERCELL-ZF-0410, comercialmente disponível, clinoptilotita proveniente de Cuba, por possuir características físicas semelhantes à do carvão antracito. Foram realizados ensaios de caracterização morfológica (MEV-FEG) e elementar (EDS), de caracterização física (granulometria, massa específica, tamanho efetivo e coeficiente de desuniformidade), de lixiviação e de filtração em escala piloto. Da análise de caracterização morfológica, verificou-se que a Zeólita em estudo tem alta capacidade de adsorção, com predisposição para adsorção de ferro, manganês e enxofre, em escala superior ao carvão antracito. Da análise de caracterização física, verificou-se que a Zeólita em estudo é um material uniforme, bem graduado, possui equivalência física com o carvão antracito e pode ser utilizada como material filtrante de segunda camada. Da análise de lixiviação, verificou-se que, possivelmente, não haverá desprendimento, acima do valor máximo permitido na Resolução Conama n.° 357/2005, dos metais detectados no extrato lixiviado para a água de lavagem de um filtro que utilize esse material como meio filtrante, bem como, possivelmente, não ocorrerá desprendimento destes metais no sistema de disposição final deste resíduo. Da análise da filtração em escala piloto, concluiu-se que é viável a concepção de um projeto de filtro a gravidade, com filtração descendente, ação de profundidade e dupla camada, utilizando a Zeólita WATERCEL-ZF-0410 como material de segunda camada e que, esta concepção de tratamento, nas condições, parâmetros e configurações estudadas, apresentou eficiência média de: 100,00% para remoção de manganês; 96,17% para remoção de ferro; 99,90% para remoção de cor aparente; e 98,96% para remoção de turbidez.
244

Influência da taxa de aplicação superficial e da concentração de ar na eficiência de clarificação de água de abastecimento em unidades de flotação por ar dissolvido / Influence of surface application fee and concentration of air in efficiency of clarification of water supply in units dissolved air flotation

Escher, Aline Eléia 22 September 2011 (has links)
Os objetivos deste trabalho foram verificar a influência das taxas de aplicação superficial das zonas de separação e de contato e da concentração de micro bolhas de ar na eficiência da remoção de partículas em unidades de flotação aplicadas ao tratamento de água para abastecimento público e, caracterizar a estrutura de escoamento no interior da zona de separação, com a utilização de uma planta piloto de flotação por ar dissolvido. Os trabalhos relativos à pesquisa foram divididos em duas etapas: a primeira delas contemplou a operação de unidade piloto alimentada com água sintética, utilizando três valores de taxa de aplicação superficial na zona de separação associadas a duas taxas de aplicação superficial na zona de contato, cada qual com três concentrações de ar fornecido à flotação. Foram mantidos fixos os parâmetros: tempo de contato na zona de contato, tempo de floculação, gradiente médio de floculação e velocidade cross-flow. Os resultados desta etapa foram monitorados com base na eficiência de remoção de cor e turbidez. As maiores eficiências de remoção, 87,5% para turbidez e 96,8% de cor aparente foram obtidos para as menores taxas de aplicação superficial nas zonas de contato e separação estudadas, associadas à concentração de ar de 4,90 g/\'CM POT.3\' de água. Este, entre outros resultados, levou à conclusão de que tal concentração de ar fornecida à flotação forneceu sempre os menores residuais de cor e turbidez nas condições investigadas. Quanto à taxa de aplicação superficial na zona de contato, 136,3 m/h resultou em maiores eficiências de clarificação, sendo que o aumento para 172,8 m/h causou ligeira queda na eficiência. Finalmente, quanto à taxa de aplicação superficial na zona de separação, a menor taxa (9,8 m/h) foi aquela onde as maiores eficiências de clarificação foram obtidas, as quais decresceram à medida que a taxa foi aumentada. Na segunda etapa utilizou-se a sonda microADV na caracterização do escoamento no interior da zona de separação. Foram realizadas caracterizações para as três concentrações de ar fornecidas para a flotação estudadas na etapa I, mantendo-se fixos a taxa de aplicação superficial e o tempo na zona de contato (136,3 m/h e 53 s, respectivamente), a taxa de aplicação superficial na zona de separação (12,3 m/h), a vazão de entrada e a velocidade cross-flow, conforme a etapa I. Para as três condições estudadas, adotou-se uma malha virtual de coleta de dados de duas dimensões, composta por 98 pontos igualmente espaçados, sendo 14 na altura e 7 paralelos ao comprimento. O tempo de coleta de dados em cada ponto foi de 2 min com uma freqüência de amostragem de 50 Hz. Os vetores de velocidade resultantes foram plotados em esquemas ilustrativos, afim de se comparar os três perfis obtidos. Observou-se em todos os casos um fluxo em curto-circuito na região superior da zona de separação e logo abaixo desta, um fluxo descendente no sentido dos coletores ao fundo da unidade. Quando comparadas, apenas pequenas diferenças quanto à espessura da região de curto circuito superior foram verificadas entre as três situações abordadas, as quais não explicam as diferentes eficiências de clarificação obtidas na etapa I da pesquisa, relacionadas à concentração de ar fornecida à flotação. / The objectives of this study were to determine the influence of hydraulic surface loading of contact and separation zones and of the air micro bubbles concentration in the particle removal efficiency in flotation units applied to water treatment for public supply and also characterize the flow structure into the separation zone. The works were divided into two stages: the first included the operation of the pilot plant fed with synthetic water, using three values of hydraulic surface loadings in the separation zone associated with two hydraulic surface loadings in the superficial zone of contact, each one with three concentrations of air supplied to the flotation. Were kept fixed parameters: contact time in the contact zone, flocculation time, mean flocculation gradient and cross-flow velocity. The results of this step were monitored based on the removal efficiency of color and turbidity. The higher removal efficiencies, 87.5% of turbidity and 96.8% apparent color were obtained for the lower hydraulic surface loading of contact and separation zones studied, associated with air concentration of 4.90 g/\'CM POT.3\' of water. This, among other results, led to the conclusion that this air supplied to the flotation concentration always provided the lowest residual color and turbidity values, under the conditions investigated. As for the hydraulic surface loading in the contact zone, 136.3 m/h resulted in higher efficiencies for clarification and when increasing to 172.8 m/h slight drop in efficiency was caused. Finally, regarding separation zone hydraulic surface loading, the lowest rate (9.8 m/h) was the one in which the highest efficiencies of clarification were obtained, which decreased, as the hydraulic surface loading was increased. In the second step, the probe microADV was used to characterize the flow inside the separation zone. Characterizations were carried out for the three air concentrations supplied to the flotation studied on the first step, fixing contact zone hydraulic surface loading and time (136.3 m/h and 53 s, respectively), the separation zone hydraulic surface loading (12.3 m/h), the input flow and cross-flow velocity as step I. For the three conditions studied, we adopted a of two-dimensional virtual data collection grid with 98 equally spaced points, 14 in height and 7 parallel to the length. The data collection time at each point was 2 min with a sampling frequency of 50 Hz. The resulting velocity vectors were plotted on illustrative diagrams in order to compare the three profiles obtained. A short-circuit flow in the upper part of the separation zone and below this, a downward flow toward the bottom of the collector unit were observed in all cases. In comparison, only small differences in the thickness of the upper region of short circuit were observed between the three situations discussed, which do not explain the different efficiencies of clarification obtained in the first step of the research related to the air bubble concentration.
245

Preparação de catalisadores magnéticos para aplicação em fotocatálise heterogênea e ozonização catalítica heterogênea de poluentes emergentes / Preparation of magnetic catalysts for application in heterogeneous photocatalysis and heterogeneous catalytic ozonation of emerging pollutants

Ciccotti, Larissa 28 May 2014 (has links)
O presente trabalho descreve a preparação de catalisadores magnéticos para aplicação nos processos de fotocatálise heterogênea e ozonização catalítica heterogênea, visando a degradação de poluentes emergentes. Primeiramente buscou-se preparar nanopartículas magnéticas para posterior aplicação no preparo de catalisadores magnéticos de TiO2. Diversas variáveis experimentais foram avaliadas na preparação das nanopartículas magnéticas, tais como: temperatura de reação, tempo de agitação, tempo no ultrasom, velocidade de agitação, velocidade de agitação da base, tempo de agitação do estabilizante, concentração da base e do estabilizante. A influência destes parâmetros de preparação no diâmetro hidrodinâmico e distribuição de tamanho das partículas foi avaliada por meio de um planejamento estatístico. Dependendo das condições experimentais, obteve-se materiais com um tamanho médio variando entre 11 e 36 nm e entre 23% e 77% de distribuição de tamanho. Na condição otimizada, obteve-se partículas com um tamanho médio, obtido pela técnica de espalhamento de luz dinâmico, de 18 nm e 21% de distribuição. O nanomaterial magnético foi utilizado para preparar os catalisadores híbridos Fe3O2@TiO2 e Fe3O4@SiO2@TiO2. Os materiais foram caracterizados por difratoemtria de raios-X (XRD), microscopia de varredura (MEV) e transmissão (TEM), espectroscopia no infravermelho (FT-IR), análise térmica (TG e DTA), espectrometria de emissão óptica (ICP-OES), medidas de área superficial (BET) e espalhamento dinâmico de luz (DLS). Os catalisadores magnéticos foram empregados na degradação dos poluentes emergentes paracetamol; 4-metilaminoantipirina (4-MAA); ibuprofeno; 17 β-estradiol; 17 α-etinilestradiol, e do fenol. Nos processos de degradação também variou-se o efeito do pH nas respostas dos sistemas. De maneira geral, o material Fe3O4@TiO2 apresentou atividade catalítica nos processos de degradação fotoquímica e de ozonização, com desempenho similar ou, em alguns casos, superior ao TiO2. Em relação a 4-MAA, obteve-se, em 60 minutos de tratamento, 25% de mineralização para o processo de fotólise e 66% para o processo de fotocatálise empregando Fe3O4@TiO2. Para o processo de ozonização em pH 3, obteve-se, em 180 minutos de tratamento, 40 e 60% de mineralização para o processo não catalítico e o processo catalítico empregando Fe3O4@TiO2, respectivamente. Os resultados utilizando-se TiO2 foram semelhantes à ozonização não catalítica, o que demonstra o efeito positivo do núcleo magnético para a atividade do material. Assim, o material híbrido multifuncional Fe3O4@TiO2 mostrou-se eficiente para a degradação de poluentes emergentes empregando-se os processos de fotocatálise e de ozonização catalítica heterogênea, possibilitando uma adicional praticidade de separação do meio de tratamento. / The present work describes the preparation of magnetic catalysts for application in heterogeneous photocatalysis and heterogeneous catalytic ozonation processes, aiming the degradation of emerging pollutants. Magnetic nanoparticles were prepered as substratum of magnetic TiO2 catalysts. Several experimental variables were evaluated in the preparation of the magnetic nanoparticles, such as temperature, stirring time, sonication time, precipitation reaction stirring speed, base addition rate, dispersion stirring time, base concentration and stabilizer percentage. The influence of these parameters on particle hydrodynamic diameter and size distribution were measured by a statistical design. Depending on the experimental conditions, materials with an average size ranging between 11 nm and 35 nm and distribution between 23% and 77% were obtained. In the optimum preparation conditions, Fe3O4 magnetic particles with a hydrodynamic diameter of 18 nm and 21% distribution were obtained. The magnetic nanomaterial was used to prepare the hybrid catalysts Fe3O4@TiO2 and Fe3O4@SiO2@TiO2. The prepared materials were characterized by X-ray diffraction (XRD), field-emiss ion scanning electron microscopy (FEG-SEM), transmission electron microscopy (TEM), Fourier transform infrared spectroscopy (FT-IR), thermogravimetric (TG), differential thermal analysis (DTA), inductively coupled plasma optical emission spectrometry (ICP-OES), BET specific surface area and dynamic light scattering (DLS). The magnetic catalysts were employed in the degradation of the emerging pollutants paracetamol; 4-methylaminoantipyrin (4-MAA); ibuprofen; 17 β-estradiol; 17 α-ethinyl estradiol, and phenol. In the treatment processes the effect pH on the systems was also varied. In general, the material Fe3O4@TiO2 showed catalytic activity in the processes of photochemical degradation and ozonation, with performance similar or, in some cases, superior to TiO2. For example, the 4-MAA mineralization, after 60 minutes of treatment, by the photolysis process reached a m aximum value of 25%. In the same treatment time by the photocatalytic process using Fe3O4@TiO2 it was obtained 66% of 4-MAA mineralization. For the ozonation process, in pH 3, after 180 minutes of treatment, 40% of 4-MAA mineralization was achieved by non-catalytic method. On the other hand, in the same treatment time employing Fe3O4@TiO2, 60% of 4-MAA mineralization was obtained. In addition, for the ozonation process using TiO2 similar results to non-catalytic ozonation were observed, which demonstrates the positive effect of the magnetic core for the activity of the catalyst. Thus, the hybrid material Fe3O4@TiO2 was efficient for the degradation of emerging pollutants employing the photocatalysis and heterogeneous catalytic ozonation processes, allowing an additional practicality for separating the catalyst from the treatment medium.
246

Pré-cloração associada à adsorção em carvão ativado em pó e flotação por ar dissolvido na remoção de microcistina presente em três diferentes concentrações em águas provenientes de reservatório eutrofizado / Prechlorination associated to adsorption with powdered activated carbon and dissolved air flotation in the removal of three concentrations of microcystin present in eutroficated reservoir water

Rosa, Andrey Alexsandro 13 June 2008 (has links)
O crescimento desordenado das cidades, a utilização de áreas para plantio próximas aos mananciais e o lançamento de águas residuárias domésticas e industriais sem tratamento são consideradas as principais fontes de poluição dos corpos d´água. Tal poluição contribui para o enriquecimento dos corpos hídricos em relação aos nutrientes. Isto, combinado com fatores climáticos proporciona condições para a ocorrência de florações de algas que podem apresentar espécies potencialmente tóxicas. Desta forma, aumenta a preocupação com desenvolvimento de técnicas de tratamento que forneçam água de qualidade garantindo a saúde da população consumidora. Nesta pesquisa, foram preparadas águas de estudo com diferentes concentrações de microcistina, com as quais foram testados alguns processos de tratamento, em escala de bancada, que consistiram na pré-cloração, adsorção em carvão ativado em pó, coagulação/floculação, flotação por ar dissolvido e centrifugação. O fluxograma de tratamento com aplicação de carvão ativado logo após a mistura rápida foi o que apresentou melhores resultados em termos de cor aparente, turbidez e concentração residual de microcistina. Foi avaliada a influência da concentração de microcistina nos tratamentos simulados. Constatou-se que para 104,92 µg/L de microcistina a aplicação de 3,0 mg\'CL IND.2\'/L (10 segundos antes da mistura rápida) e 30 mg/L de CAP (logo após a mistura rápida) não foram capazes de reduzir a concentração de microcistina para menos de 1 µg/L, conforme o limite estabelecido pela Portaria 518/04 do Ministério da Saúde. Assim, optou-se pela estimativa da dosagem mínima de carvão ativado em pó (CAP) em função da concentração inicial de microcistina das três águas preparadas. O residual de microcistina em cada água preparada, após a aplicação da dosagem estimada de CAP, foi: Água de Estudo 1 = 0,80 µg/L, Água de Estudo 2 = 0,82 µg/L e Água de Estudo 3 = 0,23 µg/L. / The disordered growth of cities, the use of planting areas near the water sources and the launch of domestic and industrial wastewater without treatment are the main sources of water bodies\' pollution. Such pollution contributes to increase the nutrient loading in the water bodies. In association with climatic factors, this enrichment of nutrient provides suitable conditions for the bloom of potentially toxic algae. Thus, increases the concern over to develop treatment techniques that provide water quality able to ensure the health of the consumer population. In this research, waters were prepared with different concentrations of microcystin and some treatments were tested in bench scale. These tests consisted in prechlorination, adsorption on powdered activated carbon, coagulation/flocculation, dissolved air flotation and centrifugation. The diagram of treatment with activated carbon application after the rapid mix showed better results of apparent color, turbidity and residual concentration of microcystin. The influence of the concentration of microcystin in the simulated treatments was evaluated. It was found that for 104.92 µg/L of microcystin the application of 3.0 mg\'CL IND.2\'/L (10 seconds before rapid mix) and 30 mg/L of PAC (after a quick mixture) were not able to reduce the concentration of microcystin to less than 1 µg/L, as the limit established by Order 518/04 of the Health Ministry. Thus, it was decided to estimate the minimum dosage of powdered activated carbon (PAC) according to the initial concentration of microcystin found in the three prepared waters. The residual concentration of microcystin in each water, after the estimated dosage application of PAC was: Water 1 = 0.80 µg/L; Water 2 = 0.82 µg/L; Water 3 = 0, 23 µg/L.
247

Investigação da condição trófica do reservatório de abastecimento de água Bolonha

OLIVEIRA, Izabelle Ferreira de 04 July 2018 (has links)
Submitted by Ivone Costa (mivone@ufpa.br) on 2018-09-05T15:22:23Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_InvestigacaoCondicaoTrofica.pdf: 3592615 bytes, checksum: 108b4ba22cd3455e13a958068b19511b (MD5) / Approved for entry into archive by Ivone Costa (mivone@ufpa.br) on 2018-09-05T15:22:53Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_InvestigacaoCondicaoTrofica.pdf: 3592615 bytes, checksum: 108b4ba22cd3455e13a958068b19511b (MD5) / Made available in DSpace on 2018-09-05T15:22:53Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_InvestigacaoCondicaoTrofica.pdf: 3592615 bytes, checksum: 108b4ba22cd3455e13a958068b19511b (MD5) Previous issue date: 2018-07-04 / Este estudo concentrou-se no monitoramento de água do reservatório Bolonha, com foco na obtenção do Índice de Estado Trófico (IET) ao longo do período chuvoso e menos chuvoso do ano 2016. O local situa-se no terreno do Parque Estadual do Utinga (PEUT), mais precisamente na Avenida João Paulo II, s/n - Curió Utinga, no município de Belém-PA. O reservatório apresenta forma alongada, aproximadamente 577.127 m² de área e 1.954.000 m³ de volume d’água; sua profundidade máxima está em torno de 7.64 m. Esta pesquisa teve como objetivo avaliar o IET do reservatório Bolonha a partir da quantificação das variáveis fósforo total, transparência e aplicação de estatística descritiva, analítica e multivariada, sendo possível observar as variações distintas nos períodos de análise. A metodologia do trabalho consistiu de realização de coletas, simples e composta, de campo, para um ponto localizado na entrada da captação da ETA Bolonha, antes do gradeamento. Ao realizar comparação sazonal entre períodos chuvosos e menos chuvosos, por meio de testes de hipótese Mann Whitney, foi possível observar que as variáveis pH, alcalinidade, cor verdadeira, fósforo total e oxigênio dissolvido não apresentaram diferença significativa entre os períodos analisados. As demais variáveis - cor aparente, sólidos suspensos totais, turbidez e IET - apresentaram diferenças significativas, entre os períodos chuvoso e menos chuvoso. A presença de fósforo é evidente em ambos os períodos. O teste de Mann Whitney revelou que houve diferença significativa das frações de fósforo entre os períodos chuvoso e menos chuvoso, através dos valores ρ. Tal teste demonstrou que as frações do fósforo analisadas apresentaram diferenças significativas (p<0,05), menor que o nível de significância de 5%. Por meio de análise de componente principal para o fracionamento do fósforo, foi possível observar a formação de 2 componentes distintos para cada período (chuvoso e menos chuvoso), que juntos explicaram 93% e 92,6% da variabilidade dos dados. O IET foi calculado para o Bolonha, o que permitiu classificar o reservatório Bolonha como um ambiente eutrófico, tanto no período chuvoso quanto no menos chuvoso. / This study focused on the monitoring of water in the Bolonha reservoir, with a focus on obtaining the Trophic State Index (IET) during the rainy and less rainy period of the year 2016. The site is located on the grounds of the Utinga State Park (PEUT), which is located at Avenida João Paulo II, s / n - Curió Utinga, in the municipality of Belém-PA. The reservoir has an elongated shape, approximately 577,127 m² of the area and 1,954,000 cubic meters of water volume; its maximum depth is around 7.64 m. The objective of this research was to evaluate the IET of the Bolonha reservoir from the quantification of the total phosphorus and transparency variables and the application of descriptive, analytical and multivariate statistics, and it was possible to observe the distinct variations in the analysis periods. The methodology of the work consisted in the accomplishment of composite and straightforward field collections, to a point, located at the entrance of the ETA Bolonha capture, before the grating. When a seasonal comparison between less rainy and rainier periods was carried out, using the Mann Whitney hypothesis tests, it was possible to observe that pH, alkalinity, accurate color, total phosphorus and dissolved oxygen did not show a significant difference between the analyzed periods. The other variables as visible color, total suspended solids, turbidity, and IET, presented substantial differences between rainier and less rainy periods. The presence of phosphorus is evident in both periods. The Mann Whitney test revealed that there was a significant difference of the phosphorus fractions between wetter and less rainy periods, through the ρ values. The test showed that the phosphorus fractions analyzed presented significant differences (p <0.05) lower than the significance level of 5%. Through the analysis of the main component for phosphorus fractionation, it was possible to observe the formation of two distinct elements for each period (rainy and less rainy), which together explained 93% and 92.6% of the variability of the data. The IET was calculated for Bolonha, which allowed to classify the Bolonha reservoir as a eutrophic environment, both in the rainy season and in the less wet period.
248

Remoção de Giardia spp. e Cryptosporidium parvum em água de abastecimento utilizando flotação: estudo em escala de bancada e desafios de detecção / Removal of Giardia spp. and Cryptosporidium parvum in drinking water using flotation: study bench scale and detection challenges

Andreoli, Fernando César 05 September 2016 (has links)
Esta pesquisa teve como objetivo analisar a remoção de cistos de Giardia spp. e oocistos de Cryptosporidium spp. em água de abastecimento utilizando a tecnologia de tratamento de ciclo completo com flotação (coagulação, floculação, flotação e filtração) em escala de bancada e utilizando cloreto de polialumínio &#8211; PAC como coagulante. Para isso, o método de floculação em carbonato de cálcio &#8211; FCCa com e sem a separação imunomagnética &#8211; IMS foi utilizado para quantificação dos organismos. Os resultados mostraram que as etapas de coagulação, floculação e flotação (Fase1) removeram 1,55 log de cistos de Giardia spp. e 1,21 log de oocistos de Cryptosporidium spp. O tratamento apenas com filtração (Fase 2) removeu 1,2 log de cistos de Giardia spp. e 0,88 log de oocistos de Cryptosporidium spp. A combinação dos tratamentos (Fase 3) foi capaz de remover 2,64 log de cistos de Giardia spp. e 2,5 log de oocistos de Cryptosporidium spp. Na quantificação de protozoários, o método de FCCa sem IMS demonstrou ser mais econômico e com melhor recuperação do que com IMS. Também foi analisada a influência da terceira dissociação ácida no método com IMS e tal procedimento acarretou em diferenças significativas nos resultados. Mesmo atendendo aos padrões de potabilidade, o tratamento estudado não removeu completamente os protozoários, este fato demonstra a necessidade da preservação dos mananciais, do tratamento dos esgotos e da desinfecção final para maximizar as barreiras que permitam reduzir o risco microbiológico presente na água de consumo. / This research aimed to analyze the removal of Giardia spp. cysts and Cryptosporidium spp. oocysts in drinking water using the full cycle of treatment with flotation technology (coagulation, flocculation, flotation and filtration) at bench scale and using polyaluminum chloride - PAC as coagulant. For this, the flocculation in calcium carbonate - FCCa method with and without immunomagnetic separation - IMS was used for quantification of organisms. The results showed that the stages of coagulation, flocculation and flotation (Step 1) removed 1,55 log Giardia spp. and 1,21 log Cryptosporidium spp. oocysts. Only the treatment with filtration (Step 2) removed 1,2 log Giardia spp. and 0,88 log Cryptosporidium spp. oocysts. The combination of treatment (Step 3) was able to remove 2,64 log Giardia spp. and 2,5 log Cryptosporidium spp. oocysts. In quantifying of protozoa, the FCCa method without IMS proved to be more economical and better recovery than with IMS. It also analyzed the influence of the third acid dissociation in the method with IMS and this procedure resulted in significant differences in the results. Even taking into account the potability standards, the treatment studied didnt completely remove protozoa, this fact demonstrates the need for preservation of water sources, treatment of sewage and final disinfection to maximize the barriers to reduce the microbiological risk present in drinking water.
249

Análise da eficiência de um sistema combinado de alagados construídos na melhoria da qualidade das águas / Assessment of efficiency of combined constructed wetlands system for water quality improvement

Cunha, Caroline de Andrade Gomes da 14 September 2006 (has links)
Este trabalho teve como objetivo avaliar a eficiência de um sistema combinado de alagados construídos, localizado no Parque Ecológico do Tietê em São Paulo, na melhoria da qualidade das águas. A estação de estudo é composta por um canal de decantação, um canal de macrófitas flutuantes (Eicchornia crassipes, Pistia stratioides, Salvinia auriculata) e emergentes (Typha angustifolia) de fluxo superficial, e duas células paralelas de solos filtrantes de fluxo vertical descendente cultivados com arroz (Oryza sativa). As coletas de água foram realizadas mensalmente, na entrada e saída de cada etapa do sistema, no período de fevereiro, março, junho e julho de 2004 e de março a setembro de 2005. As variáveis físicas, químicas e biológicas da água foram medidas e taxas de eficiência de remoção parcial e total do sistema foram calculadas. A estação construída de alagados mostrou-se eficiente principalmente na remoção de sulfato (52%), turbidez (86%), 'DBO IND.5' (41 - 64%), fósforo total (51 – 68%), nitrogênio albuminóide (51,7%), nitrito (77,8%) e nitrogênio amoniacal (57 – 84%). Os canais de macrófitas apresentaram um alto desempenho de remoção média para maioria das variáveis analisadas no trabalho, contribuindo com a maior porção na taxa de remoção total do sistema. Durante o período de estudo, provavelmente devido à falta de manejo do sistema, observou-se a volta dos nutrientes assimilados pelas macrófitas para a coluna d`água (N, P, Fe) com a decomposição das plantas e condições de anaerobiose nos solos filtrantes. Esses fatores, juntamente com a presença dos animais do parque atraídos pelo arroz, contribuíram com o baixo desempenho do canal de macrófitas e dos solos filtrantes na remoção de cor, turbidez, ferro total e coliformes em alguns meses de coleta. Para a maioria das variáveis analisadas, a água tratada pelo sistema de alagados construídos alcançou os limites e padrões estabelecidos pela Resolução CONAMA 357/2005 para águas doces de classe 2 (BRASIL, 2005). Contudo, em função dos dados obtidos, não se pode enquadrar totalmente o efluente, embora seja esperado que com a estabilização do sistema e um manejo adequado, a água tratada consiga atingir as características exigidas e possa ser enquadrada em águas doces de classe 2. / The aim of this work was evaluate the efficiency of combined constructed wetlands, located in the Tiete Ecological Park in São Paulo, in water quality improvement. The station consists of a settling channel, one free-floating (Eichhornia crassipes, Salvinia auriculata, Pistia stratiotes) and rooted emergent macrophyte-based system (Typha angustifolia) with surface flow and two cells of vertical flow filter soils in parallel, planted with rice (Oryza sativa). The water samples were collected monthly at the inlet and outlet of each step of the system, in the period of February, March, June and July of 2004 and of March to September of 2005. The physical, chemical and biological variables of the water were measured and efficiency rates of the system were made. The constructed wetlands system mainly showed efficient removal rates in sulphate (52%), turbidity (86%), BDO (41 - 64%), total phosphorus (51 - 68%), organic nitrogen (51,7%), nitrite (77,8%) and ammonia nitrogen (57 - 84%). The settling channel and macrophyte-based system presented a high removal performance for most of the variables analyzed in the work, contributing with the largest portion in the total removal rate of the system. During the study period, probably due to the lack of system management, the return of nutrients previously uptaken (N, P, Fe) by macrophytes for the water column was observed with the decay of aging plants and anaerobic conditions in the HDS system. Those factors, added with the presence of the park´s animals attracted for the rice, contributed with the low performance of macrophyte-based and HDS system in the removal of color, turbidity, total iron and coliforms in some months of collection. For most of the analyzed variables, the water treated by the constructed wetlands system reached the limits and patterns established by the Resolution CONAMA 357/2005 for fresh water of class 2 (BRAZIL, 2005). However, due to the obtained data, the treated water cannot be totally classified as class 2, although it is expected that with the stabilization of the system and appropriate handling, the treated water reach the demanded characteristics and can be classified in fresh water of class 2.
250

Adsorção de cromo hexavalente por carvão ativado granulado comercial na presença de surfactante aniônico (LAS)

SILVA, Maria Vitória Roma da 22 September 2011 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2013-02-28T22:44:01Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AdsorcaoCromoHexavalente.pdf: 1176139 bytes, checksum: 0a7b138f5d251aa312f96a767f0af4cd (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-03-05T13:27:28Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AdsorcaoCromoHexavalente.pdf: 1176139 bytes, checksum: 0a7b138f5d251aa312f96a767f0af4cd (MD5) / Made available in DSpace on 2013-03-05T13:27:28Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AdsorcaoCromoHexavalente.pdf: 1176139 bytes, checksum: 0a7b138f5d251aa312f96a767f0af4cd (MD5) Previous issue date: 2012 / A remoção de cromo hexavalente de soluções de surfactante aniônico (LAS) por carvão ativado granulado (CAG) comercial foi estudada. Na caracterização do CAG foram empregados métodos padronizados ASTM (diâmetro médio de Sauter, dDMS e pH) e método BET (S, área superficial específica). Os grupos de superfície e PCZ do adsorvente foram determinados, pelo método de Boehm e titulação potenciométrica, respectivamente. Os resultados da caracterização do adsorvente: dDMS=2,4 mm; pH=9,0; S=677,4 m² g-1; grupos básicos (70%) comparados com os grupos ácidos e o PCZ no intervalo de (4,8-8,6). Os ensaios de adsorção do surfactante LAS foram realizados em mesa agitadora (140 rpm/24 h./27 oC); 2,0 g CAG/50 mL de solução, as concentrações do LAS foram determinadas, pelo método padrão do azul de metileno. Os resultados obtidos da remoção percentual em função da concentração inicial e da remoção percentual em função da variação do tempo em todas as concentrações de LAS estudadas foram superiores a 99 %. Os ensaios de adsorção do metal Cr(VI) (5 – 20 mg/L) foram realizados em banho termostático (140 rpm/27 oC); 2,0 g CAG/50 mL de solução; 1 e 24 horas de processo e sem e com adição de surfactante (70; 140; 210; 280; 350; 533 e 700 mg/L). As concentrações iniciais e residuais de metal foram determinadas pelo método colorimétrico da 1,5 difenilcarbazida. A adsorção do metal, sem a adição de LAS não foi satisfatória, a remoção foi em torno de 15%. O percentual de remoção do metal com adição surfactante atingiu valores, em torno de 70% para a menor concentração do metal (5 mg/L) e entre (58 – 65%) paras as demais concentrações. / The hexavalent chromium removal from solutions of anionic surfactant (LAS) by granular activated carbon (GAC) commercial was studied. At CAG characterization was used ASTM standard method (Sauter mean diameter, dDMS e pH) and method BET (S, specific surface area). Adsorbent surface group and PCZ were determined by the method of Boehm and potentiometric titration, respectively. The adsorbent characterization results: dDMS=2.4 mm, pH=9.0,S=677.4 m²/g; basic groups (70%) compared with the acidic groups and PCZ in the range (4.8 – 8.6). Tests of adsorption of the surfactant LAS were carried out in shaker (140 rpm/24 h./27ºC), 2.0 g CAG/50 mL, the LAS concentration were determined by methylene blue standard method. The removal results versus initial concentration and removal versus time of all LAS concentrations were more than 99%. The adsorption of Cr(VI) (5 – 20 mg/L) were carried out in thermostatic bath (140 rpm/27ºC); 2,0 g CAG/50 mL; 1 and 24 hours of processing; without and with addition of surfactant (70, 140, 210, 280, 350, 533 and 700 mg/L). The initial e residual concentrations of metal were determined by 1,5-diphenylcarbazide colorimetric method. The metal removal without the addition of LAS was not satisfactory values were obtained, around 15%. The metal removal with surfactant reached values, around 70% to the lowest metal concentration (5 mg/L) and between (58-65%) for the other concentrations.

Page generated in 0.0205 seconds