Spelling suggestions: "subject:"gaping"" "subject:"daping""
1 |
Kritické zhodnocení metody tapingu se zaměřením na jeho účinky / Critical evaluation of taping methods with focus on its effectsŠolcová, Veronika January 2011 (has links)
Title: Critical evaluation of taping methods with focus on its effects. Objectives: Purpose of this diploma thesis is critical evaluation of taping methods with concentration on its effects. Evaluation, comparison of contradictory statements and obtained information will be done based on a study and analysis of literature and scientific studies regarding taping methods and its efficiencies. On this base, final conclusions about real efficiency of taping will be made. Methods: In this diploma thesis, which is a critical review, document studies method will be used, along with analysis of professional scientific sources and their comparison. Results: The sport tapes (solid and elastic) and the kinesio tapes may participate on the possible mechanisms of the taping method effect. The various kinds of the tapes are different in the consequences of its effects. For lack of good scientific studies we can not clearly objectify the method of the taping. Keywords: taping, taping methods, taping efficiency, knesio taping, benefits of taping, prevention, critical review, proprioception, scars.
|
2 |
Objektivizace svalového napětí při použití kineziotapingu pomocí myotonometru / Objectification of muscle tension by myotonometer when using kinesiotapeFleišmanová, Kristýna January 2012 (has links)
UNIVERZITA KARLOVA V PRAZE FAKULTA TĚLESNÉ VÝCHOVY A SPORTU Objektivizace svalového napětí při použití kinesiotapingu pomocí myotonometru Diplomová práce Vedoucí diplomové práce: Vypracovala: PhDr. Petr Šifta, PhD. Bc. Kristýna Fleišmanová Praha, duben 2012 2 Prohlašuji, že jsem diplomovou práci zpracovala samostatně a že jsem uvedla všechny použité informační zdroje a literaturu. Tato práce ani její podstatná část nebyla předložena k získání jiného nebo stejného akademického titulu. V Praze, dne …………………… …..…………………… Bc. Kristýna Fleišmanová 3 EVIDENČNÍ LIST KNIHOVNY Souhlasím se zapůjčením své diplomové práce ke studijním účelům. Uživatel svým podpisem stvrzuje, že tuto diplomovou práci použil ke studiu a prohlašuje, že ji uvede mezi použitými prameny. Jméno a příjmení: Fakulta / katedra: Datum vypůjčení: Podpis: 4 Děkuji PhDr. Petru Šiftovi, PhD. za cenné rady, připomínky a podněty, které mi pomohly orientovat se v dané problematice, a tak ulehčily a zkvalitnily zpracování této diplomové práce. 5 ABSTRAKT Název: Objektivizace svalového napětí při použití kinesiotapingu pomocí myotonometru Cíle práce: Cílem této diplomové práce je shrnout teoretické poznatky týkající se dané problematiky a vypracovat pilotní studii zaměřenou na ověření facilitační a inhibiční funkce v kinesiotapingu. Experiment má na...
|
3 |
Influência do uso da Kinesiotaping nas respostas funcionais e eletrofisiológicas em homens fisicamente ativos / Influence of the Kinesiotaping use in the electrophysiological and functional responses in physically active menMagalhães, Igor Eduardo Jesus 10 July 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Educação Física, 2015. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2016-01-11T15:20:25Z
No. of bitstreams: 1
2015_IgorEduardoJesusMagalhaes.pdf: 1798713 bytes, checksum: a29b9cad6b2b666ae001e17f4b10ad0a (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-01-25T16:19:59Z (GMT) No. of bitstreams: 1
2015_IgorEduardoJesusMagalhaes.pdf: 1798713 bytes, checksum: a29b9cad6b2b666ae001e17f4b10ad0a (MD5) / Made available in DSpace on 2016-01-25T16:19:59Z (GMT). No. of bitstreams: 1
2015_IgorEduardoJesusMagalhaes.pdf: 1798713 bytes, checksum: a29b9cad6b2b666ae001e17f4b10ad0a (MD5) / Objetivos. O objetivo do estudo foi investigar as respostas funcionais e eletrofisiológicas do músculo sóleo de indivíduos fisicamente ativos, influenciados pelo uso da Kinesiotaping (KT). Métodos. Vinte e nove voluntários participaram deste estudo. Todos os voluntários realizaram as 3 condições: Linha de Base (LB) - sem aplicação da KT; ATIVKT - aplicação da KT em ativação; INIBKT - aplicação da KT em inibição. As condições foram aleatorizadas para os indivíduos. O desenho experimental consistia na realização de 3 séries de contração isométrica voluntária máxima (CIVM), com 5s de duração.Após a avaliação da força,foi evocado o reflexo H, que consistia na estimulação do músculo sóleo através do nervo tibial. Foram utilizados 32 disparos de corrente, intervalados por um período de 2 a 4 segundos. Ao final do estudo, por meio de cálculo em rotinas do Matlab, foram extraídos os valores de torque dos intervalos da TDF (0-30, 0-50, 0-100 e 0-200), dos parâmetros relativos ao reflexo H (Hmax, H-limiar, inclinação da curva, corrente no limiar, a 50% e a 100% do Hmax) e os valores preditos relacionados à superposição das curvas condicionadas (ATIVKT e INIBKT) sobre a curva controle (H@Limiar, H@50% e H@100%).Os valores pertinentes a amplitude do reflexo foram normalizados pela amplitude do Mmax. Os valores de corrente foram normalizados pelo 50% da corrente para se evocar o Mmax. Para a comparação da TDF, após os testes de Shapiro-Wilk, foi utilizado o teste de Friedman, com comparações de Wilcoxon em pares, para detectar diferenças entre os grupos. Para os dados relativos aos parâmetros do reflexo H, foi utilizado o ANOVA para medidas repetidas, com o teste de Bonferroni para detectar diferenças entre os grupos. A significância foi de 5% (p<0,05).Resultados.De acordo com o IPAQ, o nível de atividade física dos participantes foi classificado da seguinte forma: nível baixo (n=4), nível moderado (n=9) e nível alto (n=16). Nove voluntários foram excluídos da análise dos valores de corrente e das amplitudes pós, por não apresentarem uma medida estável da onda M ou por apresentarem erros após os cálculos realizados pelo Matlab. Não foram encontradas diferenças significantes para nenhum dos parâmetros extraídos da curva de recrutamento do reflexo H, entre as diferentes condições (P>0,05). Contudo, foi encontrada uma diferença significante no H@Limiar da condição ATIVKT quando a mesma foi comparada com a condição LB (P=0,025).Foram encontrados grandes tamanhos dos efeitos nas comparações entre a condição ATIVKT vs LB (ES=5,43) e condição INIBKT vs LB (ES=3,57). Com relação a TDF,quando as condições foram comparadas entre si, em cada intervalo de tempo, não foram encontradas diferenças significantes para a TDF em nenhuma das comparações (P>0,05). Conclusão.Os achados do presente estudo demonstraram que após a aplicação da KT no protocolo de ativação, foi possível verificar um aumento da amplitude do reflexo H para o mesmo valor de corrente necessários para evocar o reflexo H limiar na condição sem a fita. Isto pode indicar um aumento da excitabilidade dos motoneurônios verificados por uma diminuição do limiar de disparo destas fibras. Parece que uma estimulação das fibras aferentes cutâneas podem ter induzido uma diminuição do limiar dos motoneurônios por meio de uma estimulação da KT por um período de 48h. ______________________________________________________________________________________________ ABSTRACT / Objectives. The aim of the study was to investigate the functional and electrophysiological responses of the soleus muscle in physically active men, influenced by the use of Kinesiotaping (KT). Methods. Twenty nine volunteers participated in this study, all submitted to the application of KT in three different conditions: Baseline (BL) - without the KT; ACTIKT - with the KT in activation; INHIKT - with the KT in inhibition. The conditions were randomized for all participants. The experimental design consisted in the performance of 3 sets of maximal isometric voluntary contraction, with 5 s duration. After the strength evaluation, the H reflex was evoked, consisting in the stimulation of soleus muscle through tibial nerve. Thirty-two electric discharges were used, with 2-4 seconds interval between then. The torque values in the intervals of the rate of torque development (RTD) (0-30, 0-50, 0-100 and 0-200), the parameters of the H reflex (Hmax, H-Threshold, slope, current at threshold, current at 50% and current at Hmax) and the predicted values related to the superposition of the conditioning and control curves (H@Threshold, H@50% and H@max) were calculated in a Matlab subroutine. The values related to the reflex amplitude were normalized by the Mmax amplitude.The current values were normalized by 50% of the current to evoke the Mmax. After the Shapiro-Wilks test, the Friedman test was used, with the post-hoc test of Wilcoxon, to detect differences between groups for the RTD. The ANOVA of repeated measures was used with the post-hoc of Bonferroni to detect differences between groups for the H-reflex parameters. The significance level was set at 5% (P>0,05). Results. According the IPAQ, the physical activity level of the participants was classified as: low level (n=4), moderate level (n=9) and high level (n=16). Nine volunteers were excluded of the current values and C-T curves comparisons analysis because they did not present a stable measure of the M wave or by calculations errors detected in the Matlab analysis. No significant differences were found for the parameters extracted from the recruitment curve of the H-reflex between conditions (P>0,05). However, a significant difference was found at H@Threshold in the ACTIKT compared with the BL condition (P=0,025). A large effect size was found in comparisons between the ACTIKT vs BL (ES=5,43) and the INHIKT vs BL(ES=3,57). With respect to RTD, no significant difference was found between conditions and intervals (p>0,05). Conclusion. The findings of the present study demonstrated an increase of the H-reflex amplitude for the same current value needed to evoke the H-Threshold, when the activation protocol was compared to the condition without the tape. This may indicate an increase in the motoneuron excitability verified by a decrease in the threshold of these fibers. It seems like a stimulation of the skin afferents may have induced a decrease in the threshold of the motoneurons by the KT usage over 48h.
|
4 |
Os efeitos da Kinesio Taping aplicada com diferentes tensões e sentidos : um ensaio clínico controlado, randomizado e cegoLemos, Thiago Vilela 21 September 2015 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação em Ciências e Tecnologia em Saúde, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-01-18T15:55:54Z
No. of bitstreams: 1
2015_ThiagoVilelaLemos.pdf: 7295267 bytes, checksum: 4a9540da1e72feda4137b1c19ce1de45 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-02-25T13:51:19Z (GMT) No. of bitstreams: 1
2015_ThiagoVilelaLemos.pdf: 7295267 bytes, checksum: 4a9540da1e72feda4137b1c19ce1de45 (MD5) / Made available in DSpace on 2016-02-25T13:51:19Z (GMT). No. of bitstreams: 1
2015_ThiagoVilelaLemos.pdf: 7295267 bytes, checksum: 4a9540da1e72feda4137b1c19ce1de45 (MD5) / Objetivos: O objetivo deste estudo é avaliar o comportamento da temperatura, da atividade eletromiográfica (EMG), da força muscular, da amplitude de movimento (ADM) e da atividade eletroencefalográfica (EEG), após a aplicação da Kinesio Taping (KT) no músculo reto femoral, com diferentes tensões e direções. Metodologia: Trata-se de um ensaio clínico randomizado e cego, com uma amostra de 32 sujeitos jovens saudáveis, divididos em dois grupos (n=16). No grupo A, a KT foi aplicada sobre a região do músculo reto femoral do membro dominante, no sentido de origem para inserção muscular (facilitação) e, no grupo B, da inserção para origem (inibição). O membro não dominante foi usado como controle, sem a KT. No primeiro dia a KT foi aplicada com 0% de tensão, no segundo dia com 10 a 15% de tensão e no terceiro dia com a tensão total de 75 a 100%. As avaliações foram realizadas antes, imediatamente após a aplicação da KT, e 24 horas com a presença da bandagem. Antes de cada aplicação, a musculatura foi submetida a uma vibração mecânica sobre o tendão patelar, a fim de provocar uma situação basal de desequilíbrio neuromuscular em todos os grupos. Resultados: Quando comparada a temperatura intra grupos, não houve diferença significativa entre o membro experimental, submetido às aplicações de KT, e o membro não dominante, o controle. No entanto, a temperatura do grupo A, com 24hs na tensão à 75%, obteve diferença significativa, com redução da temperatura, tanto no membro experimental (p=0,004) como no membro controle (p=0,005), entre os grupos. Quando avaliado a EMG o membro experimental do grupo A apresentou resultados significativos nos momentos pré e pós KT (p=0,003) e pós e 24hs (p=0,009) sem tensão; também pré e 24hs (p=0,009), pós e 24hs (p=0,002) a 10% de tensão; e pré e 24hs (p=0,006) a 75% de tensão. O grupo B também apresentou resultados significativos com 0% (p=0,002) e com 10% de tensão (p=0,02). Quando avaliada a força e a ADM entre os grupos não houver resultados significativos. Na EEG ocorreram alterações principalmente nas ondas Alfa e Beta no grupo A, porém os resultados não foram significativos provavelmente em decorrência da grande perda amostral. Conclusão: Conclui-se, a partir da metodologia proposta nesse estudo, que a Kinesio Taping aplicada sobre o músculo reto femoral não induz a alterações na temperatura local, na força muscular e na amplitude de movimento articular. Os valores absolutos da atividade eletroencefalográfica (EEG) sugerem alterações em áreas motoras, no entanto, sem relevância estatística. Na atividade eletromiográfica (EMG) ocorreram alterações significativas, porém, sem relação direta com a direção de aplicação. As maiores alterações desse sinal ocorreram nas aplicações de baixas tensões da KTT, sendo, 10% e nenhuma tensão. / Objectives: The aim of this study is to evaluate the temperature, the electromyographic (EMG) activity, the muscle strength, the range of motion (ROM), and electroencephalographic (EEG) after the Kinesio Taping (KT) application on the Rectus Femoral with different tensions and directions. Methods: This is a controled, randomized, blind clinical trial with a sample of 32 healthy young subjects, divided into two groups (n=16). Group A, the KT was applied on the dominant limb from the muscle origin to its insertion (facilitation), and Group B, from the insertion to its origin (inhibition). The nondominant limb was used as the control of this study without the KT. On the first day KT was applied with 0% of tension, on the second day with 10 to 15%, and on the third day with the total tension of 75 to 100%. The evaluations were performed before, immediately after the KT application, and 24 hours with the tape. Before each application, the muscle was subjected to a mechanical vibration of its tendon (patellar) in order to cause a neuromuscular imbalance. Results: The results from this study when evaluated the strength and ROM between the groups didn’t show any significant results. Significant results were presented in these outcomes when was compared the differentes moments on the experimental limb, but almost the same happenned with the control limb. When the EMG was evaluated, the experimental limb of the group A showed significant results on pre and post KT (p=0,003), and post with 24 hours (p=0,009) without tension; also on pre and 24h (p=0,009), and post with 24h (p=0,002) at 10% tension; pre with 24h (p=0,006) at 75% tension. The group B also showed significant results with 0% (p=0,002), and with 10% of tension (p=0,02). However, the temperature of the group A, in 24 hours at 75% tension had a significant difference, obtained a reduction in the temperature, both it happenned on the experimental limb (p=0,004) and also on the control limb (p=0,005) between the groups. The EEG had several changes most on the Alpha and Beta waves on group A, but due to a large sample loss due to corrupted data, the results were not statistically significant. Conclusion: There are no changes in the local temperature, muscle strength and range of motion, so changes have occurred in electroencephalographic activity (EEG), but without statistical significance. Electromyographic (EMG) activity had some statistically significant changes, but not directly related to the direction of application, and the major changes occurred on the applications with low KTT tension like 10%.
|
5 |
Effet du taping patellaire sur la cinématique en trois dimensions lors de la descente d’une marche chez les personnes ayant une lésion méniscale: une étude exploratoire / Patellar taping changes knee kinematics during a step - down task for individuals having a meniscal injury: a pre - experimental studyRoy, Nicolas January 2014 (has links)
Résumé: Les lésions méniscales sont des blessures fréquentes au genou et peuvent limiter la descente d’un escalier. À ce jour, la cinématique de la descente d’une marche d’escalier n’a jamais été étudiée dans les trois dimensions (3D) chez ces personnes. Le taping patellaire a déjà démontré des effets correcteurs sur la cinématique du genou mais ses effets n’ont jamais été étudiés chez des personnes souffrant d’une lésion méniscale. Cette étude vise à évaluer l’effet du taping patellaire ainsi que celui d’un taping sans tension sur la cinématique en 3D du genou lors de la descente d’une marche, à vitesse lente, chez cette clientèle. Dix patients ayant reçu un diagnostic de lésion méniscale, confirmé en imagerie par résonance magnétique, ont effectués cinq descentes d’une marche, à vitesse lente, sous trois différentes conditions: Aucune intervention, avec un taping patellaire et avec un taping sans tension. Les données de la cinématique en 3D ont été recueillies en utilisant un système d’analyse du mouvement de huit caméras infra-rouge de marque Vicon. Les angles maximums et minimums ainsi que l’amplitude de mouvement (angle maximal – angle minimum) dans chacun des trois plans de l’espace ont été comparés lors de la phase unipodale en utilisant une ANOVA à mesures répétées. Les résultats démontrent une réduction significative des angles maximums et minimums de flexion et de rotation interne, tout comme une réduction de l’amplitude de rotation interne lorsque la condition avec le taping patellaire est comparée aux deux autres conditions. Un décalage significatif vers des angles d’abduction plus petits est également observé avec les deux tapings par rapport à la condition de base. La tension appliquée dans le taping patellaire peut jouer un rôle bénéfique dans le contrôle du mouvement de la descente d’une marche. // Abstract: Meniscus lesions are common musculosquelettal knee injury often leading to pain, limitation and compensation in functional tasks like stair descent. To this day, no study has examined the knee’s three dimensional (3D) kinematics during this task with patients having a meniscal lesion. Patellar taping was shown to have corrective effect on the knee kinematics but its effect have never been observed on patients having a meniscal lesion. This study investigated the effect of a patellar taping and a tension-free taping on the three dimensional kinematics of the knee of patient having a meniscal lesion during a slow step descent task. Ten patients diagnosed with a meniscal lesion confirmed by magnetic resonance imaging underwent five step descent movements at slow speed under three different conditions: No intervention, tension-free taping and patellar taping with a medial tension applied. Three dimensional (3D) kinematics data were recorded at the injured knee using an eight camera infra-red Vicon motion analysis system. Maximum and minimum angle value and angle range (maximum - minimum value) in the three movement planes during single-limb stance were compared using a repeated measure ANOVA. Results showed significant reduction of the flexion and internal rotation maximum and minimum angle value, and a decreased internal rotational angle range when comparing the patellar taping with the two other conditions. A significant downward offset of the maximum and minimum abduction angle value was also observed under the two taping condition. Tension applied to taping plays a beneficial role in the control of the sagittal and transverse plane step - down movement in the patients of our study.
|
6 |
A comparison between chiropractic manipulation and Kinesio® Taping and the combination thereof on postural kyphosis15 July 2015 (has links)
M.Tech. (Chiropractic) / Postural kyphosis of the thoracic spine is a common condition which affects a large percentage of the population. With an increase in anteriorly orientated activities, such as working on a computer, driving and studying, postural kyphosis has become more prevalent. Currently, the gold standard for the treatment of postural kyphosis is the stretching of the involved anterior musculature (pectoralis major and minor) and the strengthening of the involved posterior musculature (mid trapezius, rhomboids and levator scapulae). This involves the compliance of patients in the completion of exercises and stretching routines. This often resulted in poor outcomes as routines were performed irregularly or incorrectly. Although, if properly executed, this treatment protocol is effective, chiropractors, and other manual therapists, continue to search adjunctive modalities to improve the positive outcomes of their treatments. With the introduction of Kinesio® taping, the problem of patient compliance could be reduced. The tape is applied by the practitioner and simply left for several days. It has very little effect on the patient’s day to day activities and should continue to have positive impact on the involved musculature with no additional effort required from the participant. The benefits of chiropractic manipulation on the biomechanical relationship between a joint/s and linked musculature has long been recognised. However, very little research has been done to ascertain the direct benefits of chiropractic manipulation to the cervical and upper thoracic regions on postural kyphosis. This study will not only provide valuable information on these two modalities used individually, but also on the effectiveness of the combination of the two treatments. Method: This study was a comparative study consisting of three groups of ten participants. The method of treatment was determined by random group allocation. Group 1 received spinal manipulation to restriction(s) of the cervical and upper thoracic regions only. Group 2 received Kinesio® taping to the rhomboid muscle group only. Group 3 received the combination of spinal manipulation and Kinesio® taping. Subjective measurements consisted of the measurement of the thoracic kyphosis with the use of flexicurve ruler, a series of lateral view plumb line photographs and a set of secondary measurements consisting of three inter scapular measurements, one inter acromioclavicular measurement and two C7 to acromioclavicular measurements on each side.
|
7 |
A study to determine the efficacy of chiropractic manipulation combined with Kinesio® taping in the treatment of chronic lower back pain07 November 2012 (has links)
M.Tech. (Chiropractic) / Chronic lower back pain is a very common condition affecting 60-80% of the worlds’ population at sometime in their lives. Manual therapy, including chiropractic manipulation, has been proven to be very successful in the treatment of chronic lower back pain and reduction in muscle tension. Although chiropractic treatment alone is effective in the treatment of chronic lower back pain, chiropractors often search for adjunctive modalities to enhance the positive outcomes of their treatment. Kinesio® tape application to the lumbar para-spinal muscles has been proven to be effective in increasing lumbar range of motion and in decreasing lower back pain. The purpose of this study was to determine whether the combination of Chiropractic manipulation and Kinesio® taping of the lumbar para-spinals is a more efficient, and possibly effective, treatment protocol in the treatment of chronic lower back pain. Method: This study was a comparative study and consisted of three groups of ten participants. The participants were between the ages of eighteen and forty years of age, with a male to female ration of 1:1. The potential participants were examined and accepted according to the inclusion and exclusion criteria. Group 1 received chiropractic manipulative therapy to the lumbar spine and sacroiliac joints. Group 2 only received the application of Kinesio® tape to the lumbar para-spinal muscles. Group 3 was the combination group, and received chiropractic manipulative therapy to the lumbar spine and sacroiliac joints together with the application of Kinesio® tape to the lumbar para-spinal muscles. Subjective measurements consisted of the Numerical Pain Rating Scale and the Oswestry Pain and Disability Index and objective measurements was range of motion of the lumbar spine. Procedure: Treatment consisted of seven consultations over a three week period. Objective and subjective readings were taken at the beginning of the first, fourth and seventh consultations before treatment. Subjective readings were taken from the Numerical Pain Rating scale and the Oswestry Pain and Disability index.Objective Readings were taken from measurements taken from the Digital Inclinometer device measuring lumbar range of motion. At the first to sixth consultation participants each received their groups’ specific treatment protocol, the seventh consultation consisted of data collection only.
|
8 |
The relative effectiveness of non-steroidal anti-inflammatory drugs (Ibuprofen®) and a taping method (Kinesio Taping® Method) in the treatment of episodic tension-type headachesHenry, Justin Michael January 2009 (has links)
Dissertation submitted in partial compliance with the requirements for a Masters Degree in Technology: Chiropractic, Durban University of Technology, 2009. / Headaches are one of the most common clinical conditions in medicine,
and 80% of these are tension-type headaches (TTH). TTH has a greater socioeconomic
impact than any other type of headache due to its prevalence. Within the TTH category,
episodic TTH are more prevalent than chronic TTH. The mainstay in the treatment of
TTH are simple analgesics and NSAIDs. Unless contraindicated, NSAIDs are often the
most effective treatment for ETTH. However patients suffering with TTH tend to relate
their headaches to increased muscle stiffness in the neck and shoulders and thus the
non-pharmacological treatment of ETTH could be directed at the associated
musculoskeletal components of ETTH. It is therefore proposed that the Kinesio Taping®
Method may have an effect in the treatment of the muscular component of ETTH.
Method: This study was a prospective randomised clinical trial with two intervention
groups (n=16) aimed at determining the relative effectiveness of a NSAID and the
Kinesio Taping® Method in the treatment of ETTHs. The patients were treated at 5
consultations over a 3 week period. Feedback was obtained using the: NRS – 101, the
CMCC Neck Disability Index and a Headache Diary.
Results: The Headache Diary showed a reduction in the presence and number, mean
duration and pain intensity of ETTH in both groups. These treatment effects were
sustained after the cessation of treatment with the exception of mean pain intensity in
the Kinesio Taping® Method group. The mean NRS score decreased in both groups but
at a slightly faster rate in the Kinesio Taping® Method group. The CMCC showed an
improvement in the functional ability of the patients in both groups.
Conclusion: There seems to be no significant difference in the relative effectiveness of
the treatment modalities. We can thus state that the overall short-term reduction in
symptomatology supports the use of NSAIDs or Kinesio Taping® Method in the
treatment of ETTH.
|
9 |
Efeitos da Kinesio Taping na função muscular de mulheres com dor lombar crônica inespecífica : ensaio clínico com aleatorização do tratamentoSouza Júnior, José Roberto de 11 December 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ceilândia, Programa de Pós-Graduação em Ciências e Tecnologias em Saúde, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2018-04-16T19:03:38Z
No. of bitstreams: 1
2017_JoséRobertodeSouzaJúnior.pdf: 1125409 bytes, checksum: c29ce13f9bdf780599dd52c2dc207bb1 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-04-25T20:49:37Z (GMT) No. of bitstreams: 1
2017_JoséRobertodeSouzaJúnior.pdf: 1125409 bytes, checksum: c29ce13f9bdf780599dd52c2dc207bb1 (MD5) / Made available in DSpace on 2018-04-25T20:49:37Z (GMT). No. of bitstreams: 1
2017_JoséRobertodeSouzaJúnior.pdf: 1125409 bytes, checksum: c29ce13f9bdf780599dd52c2dc207bb1 (MD5)
Previous issue date: 2018-04-25 / Introdução: Dor lombar crônica inespecífica é definida como uma dor na região lombar com duração maior que 12 semanas, que não está relacionada a patologias específicas. Diversos recursos têm sido utilizados para tratar os diferentes aspectos destes pacientes, entre estes as bandagens terapêuticas como a Kinesio Taping (KT). Alguns estudos verificaram resultados positivos da KT em aspectos como dor, incapacidade e mobilidade, todavia há pouca evidência sobre a influência desta nos aspectos musculares. Objetivo: avaliar os efeitos imediatos da Kinesio Taping sobre a função muscular dos eretores da espinha de mulheres com dor lombar crônica inespecífica que apresentam ou não um aspecto psicológico (medos e/ou crenças relacionadas à atividade física). Métodos: Ensaio clínico, com randomização do tratamento, aberto, aprovado pelo comitê de ética em pesquisa da Universidade Federal de Goiás com parecer de número 1.620.688 e registrado no Registro Brasileiro de Ensaios Clínicos - RBR5xh3ch. Foi utilizado um dinamômetro isocinético e um eletromiógrafo de superfície para avaliar a função muscular dos eretores da espinha. A Kinesio Taping foi aplicada em “I” para facilitação dos eretores da espinha seguindo as recomendações do método. Os dados foram analisados no SPSS (Statistical Package for Social Sciences) versão 23.0 considerando-se p<0,05. Resultados: Não foram encontradas diferenças significantes na força, fadiga e atividade muscular ao se comparar as avaliações realizadas sem e com a bandagem (p>0,05) nas mulheres com dor lombar que não apresentaram medos e/ou crenças relacionadas à atividade física. Observaram-se diferenças significantes na força muscular ao se comparar as avaliações realizadas sem e com a bandagem (p<0,05) nas mulheres com dor lombar que apresentaram medos e/ou crenças relacionadas à atividade física. Conclusão: Conclui-se que a KT não apresenta efeitos imediatos sobre a função muscular dos eretores da espinha de mulheres com dor lombar crônica inespecífica quando não há medos e/ou crenças relacionadas, entretanto a KT apresenta efeitos positivos sobre a força muscular quando estes estão presentes. Sugere-se que tais melhoras ocorram por efeito placebo visto que não há mudanças na atividade muscular. / Introduction: Nonspecific chronic low back pain is defined as a pain in the lumbar region lasting more than 12 weeks, which is not related to specific pathologies. Several resources have been used to treat the different aspects of these patients, among them the therapeutic taping like Kinesio Taping (KT). Some studies have verified positive results of KT in aspects such as pain, disability and mobility, however there is little evidence about its influence on muscular aspects. Objective: To evaluate the immediate effects of Kinesio Taping on the muscular function of erector spinae of women with nonspecific chronic low back pain who present or not a psychological aspect (fear and/or beliefs related to physical activity). Methods: Clinical trial, with treatment randomization, open, approved by the research ethics committee of the Universidade Federal de Goiás with the number 1,620,688 and registered in the Brazilian Registry of Clinical Trials - RBR-5xh3ch. An isokinetic dynamometer and a surface electromyography were used to evaluate the muscle function of erector spinae. The Kinesio Taping was applied in "I" for the facilitation of erector spinae following the recommendations of the method. The data were analyzed in the SPSS (Statistical Package for Social Sciences) version 23.0 considering p<0,05. Results: No significant differences were found in strength, fatigue and muscle activity when comparing the evaluations performed without and with the taping (p>0,05) in women with low back pain who do not present fear and/or beliefs related to physical activity. Significant differences in muscle strength was observed when comparing the evaluations performed without and with the taping (p<0,05) in women with low back pain who present fear and/or beliefs related to physical activity. Conclusion: It is concluded that KT does not present immediate effects on muscle function of erector spinae of women with nonspecific chronic low back pain who do not present fears and/or beliefs related, however KT has effects positive on muscle strength when these are present. It is suggested that such improvements occur by the placebo effect since there are no changes in muscle activity.
|
10 |
Aplicação de bandagem elástica em equinos – Método Kinesio TapingLima de Mattos, Luiz Henrique January 2016 (has links)
Orientador: Ana Liz Garcia Alves / Resumo: A utilização das bandagens terapêuticas vem em crescente aplicação e discussão científica na reabilitação humana. Sua aplicação vem sendo descrita através do método Kinesio Taping como uma terapia complementar com resultados promissores em relação a otimização esportiva e reabilitação pós-operatória, por isso, vem sendo transposto e implementado suas técnicas para a medicina veterinária; no entanto, nenhum estudo realizado anteriormente confirma o seu real efeito na medicina veterinária, particularmente na reabilitação de equinos. OBJETIVOS: Avaliar o efeito da aplicação de bandagem elástica – método Kinesio Taping – na fisioterapia e reabilitação equina. FORMATO DO ESTUDO: Estudo realizado em 2 etapas, sendo o primeiro estudo experimental in vivo pela avaliação da bandagem terapêutica no controle de edemas pós artroscopia em equinos; o segundo estudo experimental in vivo por meio da avaliação objetiva do movimento verificando a influência da utilização de bandagem terapêutica na biomecânica equina. RESULTADOS: Primeiro estudo: O grupo tratado demonstrou maior ativação do sistema linfático, com redução significativa do edema a partir de 24 horas do tratamento em relação ao grupo controle, porém não demonstrando diferenças de temperatura significativas na avaliação termográfica. Segundo estudo: Em exercício de trote em linha reta, houve, após a remoção das bandagens diminuição do movimento ascendente (Maxdiff) e amplitude de movimento (ROM) da cabeça; aumento da ROM em articul... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The use of therapeutic bandages come in increasing application and scientific discussion on human rehabilitation. Its application has been described by the Kinesio Taping method as a complementary therapy with promising results regarding the sports optimization and post-operative rehabilitation, so it has been transposed and implemented his techniques for veterinary medicine; However, no previous study confirms its actual effect in veterinary medicine, particularly in the rehabilitation of horses. OBJECTIVES: To evaluate the effect of the application of elastic bandage - Kinesio Taping method - in physical therapy and equine rehabilitation. STUDY FORMAT: A study carried out in two stages, the first experimental study in vivo by evaluating the therapeutic bandage on control post-arthroscopy edema in horses; the second experimental study in vivo by means of objective evaluation of the movement checking the influence of the use of therapeutic bandage on equine biomechanics. RESULTS: First study: The treated group showed greater activation of the lymphatic system, with significant reduction of edema from 24 hours of treatment compared to the control group, but not showing significant temperature differences in the thermal evaluation. According to the study: In trotting exercise straight, there was, after removing the bandages decreased upward movement (Maxdiff) and range of motion (ROM) of the head; increased ROM in lumbosacral joint, and greater symmetry of downward movement (Mi... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.0543 seconds