• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Depósito e perdas em aplicações de defensivos na cultura do cajueiro com o uso de diferentes taxas e equipamentos de aplicação / Deposit and losses on defensive cashew applications using different rates and application equipment.

Cordeiro, Igor Martins January 2013 (has links)
CORDEIRO, I. M. Depósito e perdas em aplicações de defensivos na cultura do cajueiro com o uso de diferentes taxas e equipamentos de aplicação. 2013. 56 f. Dissertação (Mestrado em Engenharia Agrícola) - Centro de Ciências Agrárias, Universidade Federal do Ceará, Fortaleza, 2013. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2015-01-30T19:58:28Z No. of bitstreams: 1 2013_dis_imcordeiro.pdf: 1160800 bytes, checksum: d8e3f754d33b131dc258f7ff5d034c1e (MD5) / Approved for entry into archive by Margareth Mesquita(margaret@ufc.br) on 2015-02-09T14:10:15Z (GMT) No. of bitstreams: 1 2013_dis_imcordeiro.pdf: 1160800 bytes, checksum: d8e3f754d33b131dc258f7ff5d034c1e (MD5) / Made available in DSpace on 2015-02-09T14:10:15Z (GMT). No. of bitstreams: 1 2013_dis_imcordeiro.pdf: 1160800 bytes, checksum: d8e3f754d33b131dc258f7ff5d034c1e (MD5) Previous issue date: 2013 / The cashew cultivation as an activity of economic importance for the Brazilian Northeast, has been going for a period of decline in productivity, largely because of the extractive scheme employed in its cultivation and the lack of minimal technical management of production factors, among them pest control. There are many factors that influence the effectiveness of a pesticide application, however much the producers give more importance to the applied product that the form how it is applied. Set the appropriate water volume to be applied in the canopy of tree crops is a difficult task due to the variability between crops. The concept of TRV has emerged as a way to adjust the amount of syrup to be applied depending on the volume of the canopy. The objective of this study was to evaluate the deposition of dye and syrup in the cashew leaf and losses of dye and syrup for ground applications in eight application rates, with four of those rates applied air carrier sprayer with a three with a motorized knapsack equipment and a manual knapsack with equipment. The experiment was driving in an area of dwarf cashew localized in Pacajus - CE. The adjustment of application equipment used at work for the air carrier sprayer was made adjustments were made in the direction of air flow, application rate and the vertical distribution profile of the syrup to the knapsack and motorized knapsack equipment of the adjustment were made application rates. Tests of spray deposition and dye in cup cashew were conducted in experimental design tracks in a split plot design where the main treatments were eight application rates, four of which applied to the air carrier sprayer (100%, 85%, 70% and 50% of the application rate of reference), three by motorized knapsack sprayer (level 6, between level 3 and 4 and level 1 flow controller) and one with manual knapsack, secondary treatments were the six points collections in the cup cashew. Tests for loss of dye and syrup to soil were conducted in the experimental design of tracks, where treatments were eight application rates used in the tests deposition in the cup. The spray deposition on the cup occurred incrementally measure that increased the rate of application, with a higher concentration at the side of the cup. Higher values of deposit of dye were found in treatments with motorized knapsack sprayer with flow regulator at level 6 and between levels 3 and 4, the air carrier sprayer applications with greater deposition of dye was found in the treatments with 70 % and 55 % the rate of application of reference. The applications with the air carrier sprayer showed greater uniformity of dye at collection points in relation to motorized and manual equipment costal rib. Greater losses of the syrup as it increased the rate of application, with the exception of the application with knapsack equipment were found. Greater losses of dye were found in applications with manual knapsack equipment, followed by the air carrier sprayer applications and motorized knapsack sprayer. Applications with motorized knapsack equipment with flow regulator at level 6 and between levels 3 and 4 were more efficient in depositing the crop cashew dye, for applications with the air carrier sprayer application rate with 55 % of the rate of application of reference is more efficient in depositing dye and with smaller losses. It can be concluded that the deposition in the leaf and loss to the soil is greater the higher the rate, but the deposition of dye on the leaf is higher in motorized knapsack sprayer and more loss of dye to the ground occurs in the application equipment knapsack.tr / A cajucultura, como atividade de importância econômica para o Nordeste brasileiro, vem passando por um período de decréscimo de produtividade, muito por causa do regime extrativista empregado no seu cultivo e pela falta de um mínimo de técnicas de manejo de produção, dentre eles o controle de pragas. Muitos são os fatores que influenciam na eficiência de uma aplicação de defensivos, porem grande parte dos produtores dão mais importância ao produto aplicado que a forma como ele é aplicado. Definir o volume adequado de calda a ser aplicado na copa de culturas arbóreas é uma tarefa difícil, devido a variabilidade existente entre os cultivos. O conceito de TRV (Tree Row Volume) surgiu como uma forma de adequar a quantidade de calda a ser aplicada em função do volume da copa da cultura. Objetivou-se com este trabalho avaliar a deposição de calda e corante na folha do cajueiro e as perdas de corante e calda para o solo em aplicações em oito taxas de aplicação, sendo quatro dessas taxas aplicadas com um turboatomizador, três com um equipamento costal motorizado e uma com equipamento costal manual. O experimento foi conduzindo em uma área de cajueiro anão precoce localizada no município de Pacajús-CE. Para as aplicações, as taxas dos equipamentos foram regulados, onde para o turboatomizador foram realizadas regulagens na orientação do fluxo de ar, taxa de aplicação e do perfil de distribuição vertical da calda, para os equipamentos costal manual e costal motorizado foram feitas a regulagem das taxas de aplicação. Os testes de deposição de calda e corante na copa do cajueiro foram conduzidos no delineamento experimental de faixas, onde os tratamentos principais foram oito taxas de aplicação, sendo quatro destas aplicadas com o turboatomizador (100%, 85%, 70% e 50% da taxa de aplicação de referencia), três pelo pulverizador costal motorizado (nível 6, entre o nível 3 e 4 e o nível 1 do controlador de vazão) e uma com o pulverizador costal manual, os tratamentos secundários foram os seis pontos de coletas na copa do cajueiro. Os testes de perdas de corante e de calda para o solo foram conduzidos no delineamento de blocos, onde os tratamentos foram as oito taxas de aplicação utilizados nos testes de deposição na copa. A deposição de calda na copa da cultura se deu de forma crescente a medida que se aumentou a taxa de aplicação, apresentando uma maior concentração na parte lateral da copa da cultura. Maiores valores de deposito de corante foram encontrados nos tratamentos com o pulverizador costal motorizado com regulador de vazão no nível 6 e entre os níveis 3 e 4, nas aplicações com o turboatomizador uma maior deposição de corante foi encontrada nos tratamentos com 70% e 55% da taxa de aplicação de referência. As aplicações com o turboatomizador apresentaram maior uniformidade de distribuição de corante nos pontos de coleta em relação aos equipamentos costal motorizado e costal manual. Maiores perdas de calda foram encontradas a medida que se aumentou a taxa de aplicação, com exceção da aplicação com o equipamento costal manual. Maiores perdas da corante foram encontradas nas aplicações com o equipamento costal manual, seguido das aplicações com o turboatomizador e com o pulverizador costal motorizado. As aplicações com equipamento costal motorizado com regulador de vazão no nível 6 e entre os níveis 3 e 4 se mostraram mais eficiente em depositar calda na cultura do cajueiro, para as aplicações com o turboatomizador a taxa da aplicação com 55% da taxa da aplicação de referência se mostrou mais eficiente em depositar corante e com menores perdas. Pode-se concluir que a deposição na folha e perda para o solo de calda é maior quanto maior a taxa, porém a deposição de corante na folha é maior no equipamento costal motorizado e a maior perda de corante para o solo se dá na aplicação com o equipamento costal manual.
2

Floto-filtração como pós-tratamento de efluente de reator anaeróbio tratando esgoto sanitário / Floto-filtration as post-treatment of an anaerobic reactor effluent

Oliveira, André Luiz de 23 February 2007 (has links)
Este trabalho compreende o estudo do desempenho de sistema piloto de floto-filtração, aplicado ao pós-tratamento de efluente de reator anaeróbio, sob diferentes taxas de aplicação superficial, quantidade de ar fornecida ao processo e leitos filtrantes. O trabalho foi dividido em duas fases: ensaios preliminares (fase 1) e ensaios com o floto-filtro (fase 2), sem utilização de leito filtrante (etapa 1 da fase 2) e com utilização do leito filtrante (etapa 2 da fase 2). A fase 1, realizada com unidade de flotação por ar dissolvido em escala de bancada, apresentou resultados satisfatórios em termos de redução de turbidez, cor e Abs254nm para dosagens de cloreto férrico entre 40 a 80 mg/L na maior parte dos ensaios. Os dados desta fase serviram principalmente para a determinação e adoção dos melhores parâmetros operacionais a serem utilizados na fase seguinte. Na etapa 1 da fase 2, o sistema foi analisado sob a ótica da qualidade da água produzida em condições variáveis de dosagem de cloreto férrico, tempo e gradiente de floculação, taxa de recirculação e taxa de aplicação superficial. Para as amostras coletadas foram analisadas as variáveis turbidez, temperatura, condutividade, DQO, SST, pH, cor, Abs254nm, metais, OD, \'P-PO IND.4\'POT.3-\', NTK e \'N-NH IND.4\'POT.+\'. Foram obtidas eficiências globais de 88 a 97% de redução na turbidez (residual < 20 uT), 84 a 98% de SST (residual < 25 mg/L), 87 a 94% de \'DQO IND.B\' (residual < 60 mg/L), 78 a 92% de \'DQO IND.F\' (residual < 40 mg/L), 85 a 96% de \'P-PO IND.4\'POT.3-\' (residual < 2 mg/L) e menor que 30% para NTK e \'N-NH IND.4\'POT.-\'. Na etapa 2 da fase 2, além das análises supracitadas, foram analisadas as variáveis DBO, coliformes totais e fecais, sulfatos, dureza, alcalinidade, ácidos voláteis e turbidez ao longo do leito filtrante além da medida de perda de carga no decorrer da carreira de filtração. Foram monitorados a perda de carga ao longo do leito filtrante, carreira de filtração. Nesta fase, a instalação piloto de floto-filtração foi avaliada mediante a variação da taxa de aplicação superficial e do leito filtrante. Os resultados foram positivos com efluente final apresentando turbidez média abaixo de 2 uT e duração média da carreira filtração de 24 horas. Foram obtidas eficiências globais de 96 a 99% de redução na turbidez (residual < 7 uT), 96 a 99% de SST (residual < 6 mg/L) , 93 a 96% de \'DQO IND.B\' (residual < 40 mg/L), 89 a 97% de \'DQO IND.F\' (residual < 34 mg/L), 93 a 98% de \'P-PO IND.4\' POT.3-\' (residual < 0,3 mg/L), menor que 30% para NTK e \'N-NH IND.4\' POT.-\', 96 a 98% de cor (residual < 50 uC) e 80 a 82% de Abs254nm (residual < 0,198). Desta forma, em virtude dos bons resultados apresentados, pôde-se constatar que a floto-filtração é uma alternativa atraente no pós-tratamento de efluente de reator anaeróbio. / This works assesses the performance of a floto-filtration pilot system, applied to the post-treatment of an anaerobic reactor effluent, under different superficial application rates, amount of air supplied to the process and filter beds. The work was divided in two phases: preliminary essays (phase 1), essays with the floto-filter without using filter bed (step 1 of phase 2) and essays with the floto-filter using filter beds (step 2 of phase 2). Phase 1, carried out with bench scale dissolved air flotation unit, presented satisfactory results regarding turbidity removal, color and Abs254nm for ferric chloride dosages between 40 - 80 mg/L in most of the essays. The data acquired from this phase were mainly used to determine and adopt the best operational parameters to be employed in the following phase. In step 1 of phase 2, the system was analyzed concerning the quality of the water produced in favorable conditions for ferric chloride dosages, time and flocculation gradient, recirculation gradient and superficial application rate. The following variables were analyzed from the collected samples: turbidity, temperature, conductivity, COD, TSS, pH, color, Abs254nm, metais, OD, \'P-PO IND.4\'POT.3-\', NTK and \'N-NH IND.4\'POT.+\'. Global efficiencies of 88 to 97% for turbidity removal (residual < 20 uT), 84 to 98% for TSS (residual 25 mg/L), 87 to 94% for COD (residual < 60 mg/L), 78 to 92% for CODF (residual < 40 mg/L), 85 to 96% \'P-PO IND.4\'POT.3-\' (residual < 2 mg/L) and less than 30% for NTK and \'N-NH IND.4\'POT.+\' were obtained. In step 2 of phase 2, besides the aforementioned analyses, BOD, total and fecal coliforms, sulphates, hardness, alkalinity, volatile acids and turbidity throughout the filter in addition to the measure of headloss during the filter run. In this phase, the floto-filtration pilot plant was assessed varying the superficial application and filter bed rate. The results were positive with the final effluent presenting mean turbidity below 2 uT and mean filter run time of 24 hours. Global efficiencies of 96 to 99% for turbidity removal (residual < 7 uT), 96 to 99% for TSS (residual < 6 mg/L), 93 to 96% for \'COD IND.B\' (residual < 40 mg/L), 89 to 97% for \'COD IND.F\' (residual < 34 mg/L), 93 to 98% for \'P-PO IND.4\'POT.3-\' (residual < 0,3 mg/L), less than 30% for NTK and \'N-NH IND.4\'POT.-\', 96 to 98% for color (residual < 50 uC) and 80 to 82% for Abs254nm (resisual < 0,198). Thus, due to the good results that were presented, it can be said that floto-filtration is an attractive alternative for the post-treatment of an anaerobic reactor effluent.
3

Influência da velocidade cross-flow na câmara de flotação na eficiência de unidades de flotação por ar dissolvido tratando água para abastecimento / The influence of cross-flow velocity in the flotation chamber on efficiency of a dissolved air flotation unit treating drinking water

Araújo, Cláudio Júnior 07 October 2010 (has links)
O reator de FAD deve propiciar condições adequadas para contato entre as micro-bolhas e os flocos formados no pré-tratamento e também condições para que o conjunto floco/bolha possa ser direcionado ao topo do reator, e assim ser removido. O projeto de pesquisa visou estudar condições hidrodinâmicas proporcionadas pela variação da Velocidade Cross-Flow (VCF) e assim verificar a influência na eficiência de uma estação piloto de flotação por ar dissolvido. A VCF é importante parâmetro para concepção de unidades de FAD e é função da vazão de entrada no tanque de flotação e da área entre o nível d\'água no tanque de flotação e o anteparo que separa a zona de contato da zona de separação. A velocidade cross-flow constitui um parâmetro de grande importância para projetos de unidades de flotação. Nesta região de transição entre a zona de contato e a zona de separação, ocorre a passagem do conjunto floco/bolha, e turbulência excessiva pode causar o rompimento do conjunto e assim comprometer a eficiência da flotação. Além disso, o padrão de escoamento observado na zona de separação dos flotadores, onde ocorre a separação dos aglomerados \"flocos + bolhas\", depende fortemente do valor médio da velocidade cross-flow, conforme comentado por Lundh et al. (2000 e 2002) e por Reali e Patrizzi (2007). Daí a necessidade de se investigar mais profundamente a influência da VCF na eficiência da clarificação por flotação. O projeto de pesquisa foi dividido em duas etapas. Para realização das etapas foi estudado um tipo de água preparada em laboratório, através da adição de substância húmica e caulinita, para obtenção de cor aparente e turbidez, respectivamente. A água estudada possui cor aparente e turbidez moderada (1 mg/L de substância húmica e 8,5 mg/L de caulinita) resultando em valores de turbidez por volta de 7 NTU e cor aparente por volta de 40 UH. A etapa 1 consistiu na determinação do par, pH de coagulação e dosagem de coagulante (sulfato de alumínio), gradiente médio de floculação e tempo médio de floculação adequado para a água de estudo. Para realização da etapa 1 foi utilizado equipamento de flotação de bancada de regime de batelada (Flotateste), que se encontra nas dependências do Laboratório de Tratamento Avançado e Reuso de Águas - LATAR/SHS/EESC/USP. Foram mantidos fixos os seguintes parâmetros: \'T IND.MR\', \'G IND.MR\', \'T IND.F\', \'G IND.F\', \'P IND.SAT\', \'T IND.REC\', \'V IND.FLOT\'. Conforme preconizado por Reali et al (2007), foi variada a dosagem de coagulante. Após determinado o melhor par pH e dosagem de coagulante foram realizados ensaios visando determinar o melhor \'G IND.F\' e \'T IND.F\' para a água em estudo. Para a água de estudo foram escolhidas duas condições de potencial Zeta, determinados na etapa 1 do projeto de pesquisa. A primeira condição o potencial Zeta permaneceria com valor próximo de 0 mV e na segunda condição o potencial Zeta seria positivo, por volta de +12 mV. A etapa 2 consistiu em variar a velocidade cross-flow, através da variação da altura do vertedor de saída da água flotada de uma unidade piloto de flotação, de forma a se obter diferentes valores de VCF (mantendo-se constantes os valores de tempo de contato e taxa de aplicação superficial na zona de contato), para dois valores de Taxas de Aplicação Superficial (TAS) (7,67 m/h e 15 m/h) na zona de separação e os dois valores de potencial Zeta (PZ), e com isto avaliar a sua influencia na eficiência de remoção de sólidos suspensos totais, cor e turbidez da instalação piloto retangular de FAD. / The reactor DAF should provide adequate conditions for contact between the micro-bubbles and the flakes formed in the pretreatment conditions and also for the aggregate flocs/bubble can be directed to the top of the reactor, and thus be removed. The research project aimed at studying hydrodynamic conditions provided by the variation of Cross-Flow Velocity (VCF) and thus checks the influence on the efficiency of a pilot plant of dissolved air flotation. The VCF is an important parameter to design units of DAF and is a function of input flow in the flotation tank and the area between the water level in the flotation tank and the bulkhead that separates the contact zone of the zone of separation. The cross-flow velocity is a parameter of great importance to projects of flotation units. In this region of the transition zone between the contact zone and the separation zone, occurs the passage of the aggregate flocs/bubble, and excessive turbulence can cause disruption of the aggregate and thereby harm the flotation efficiency. Moreover, the pattern of flow observed in the flotation separation zone, which occurs the separation of aggregates \"flakes + bubbles\", depends strongly on the average value of cross-flow velocity as described by Lundh et al. (2000 and 2002) and Reali and Patrizzi (2007). Hence the needs to investigate further the influence of VCF on the clarification efficiency by flotation. The research project was divided into two steps. To perform the steps has been studied a type of water prepared in the laboratory, through the addition of humic substances and kaolin, to obtain apparent color and turbidity, respectively. The study water has moderate turbidity and apparent color (1 mg/L of humic substance and 8.5 mg/L of kaolin) resulting in turbidity values around 7 NTU and color apparent by 40 HU. Step 1 consisted in the determination of the pair, coagulation pH and coagulant dosage (aluminum sulfate), flocculation gradient and time flocculation suitable for the study water. For the implementation of step 1 was used bench batch flotation system equipment (Flotatest), located on the Laboratory for Advanced Treatment and Reuse Water - LATAR / SHS / EESC / USP. Were kept fixed the following parameters: \'T IND.MR\', \'G IND.MR\', \'T IND.F\', \'G IND.F\', \'P IND.SAT\', \'T IND.REC\', \'V IND.FLOT\'. As predicted by Reali et al (2007), was varied the dosage of coagulant. After determined the best pair of coagulant dosage and pH coagulation the tests were performed to determine the best \'G IND.F\' and \'T IND.F\' for the study water. For the study water were chosen two conditions of Zeta potential values, determined in the step 1 of the research project, where the first condition the Zeta potential value kept near 0 mV and the second condition kept a positive value of Zeta potential, around +12 mV. The step 2 consisted of varying the cross-flow velocity, by varying the height of the outlet weir of the clarified water of the flotation pilot plant to obtain different values of VCF (keeping constant the values of time contact and application rate on the contact zone) for two values of superficial application rates (7.67 m/h and 15 m/h) in the zone of separation and the two values of Zeta potential (PZ) and then was availed the influence on removal efficiency of total suspended solids, colour and turbidity of the rectangular pilot plant of DAF.
4

Tecnologias de aplicação do imidacloprido no controle do pulgão-dos-cereais (Schizaphis graminum) em trigo e seus efeitos sobre inimigos naturais Uberlândia Minas Gerais – Brasil 2017 / Imidacloprid application technologies for the control of wheat aphid (Schizaphis graminum) and its effects on natural enemies

Machado, Willian Alves 31 July 2017 (has links)
Uma das principais espécies encontradas em trigo é o pulgão-dos-cereais, Schizaphis graminum (Rondani, 1852), o qual reduz substancialmente a produção de grãos, retarda o crescimento de raízes e prejudica o perfilhamento. Como consequência do ataque, é comum a aplicação de inseticidas que mal manejados acarretam uma série de prejuízos econômicos e ambientais. O objetivo desse trabalho foi estudar as combinações entre taxas de aplicação, pontas e adjuvantes no controle químico do pulgão-dos-cereais na cultura do trigo e os impactos ambientais sobre as populações de seus inimigos naturais. Foram realizadas aplicações de inseticida imidacloprido em dois campos de multiplicação de sementes da cultivar BRS 404. Foram utilizadas duas taxas de aplicações (75 e 150 L.ha-1) com e sem a adição de dois adjuvantes de características químicas diferentes combinados com três tipos de pontas hidráulicas de pulverização. Para os estudos laboratoriais de avaliação das propriedades físico-químicas das caldas, por meio da avaliação de variância houve interação significativa das propriedades condutividade e tensão superficial com os adjuvantes avaliados. Em relação às tecnologias empregadas, a deposição de calda aplicada nas folhas bandeira e espigas na taxa de aplicação menor (75 L ha-1) foi estatisticamente similar ao da deposição em taxa de aplicação maior (150 L ha-1), independente do uso de adjuvante. Quanto ao controle do pulgão-dos-cereais, os tratamento que apresentaram alta eficiência ao longo de todo o período de avaliação de controle foram aqueles que continham adjuvantes nas duas taxas de aplicações testadas (75 L ha-1 e 150 L ha-1) demonstrando ser possível a redução do volume de calda em aplicações que tenham como objetivo o controle do pulgão-dos-cereais sem que haja perda de eficácia no tratamento. O inseticida imidacloprido mostrou ser altamente nocivo aos predadores do pulgão-dos-cereais, Chrysoperla externa e Orius insidiosus, ocasionando mortalidade logo nos primeiros três dias após a aplicação, independente da tecnologia de aplicação empregada. / One of the main species found in wheat is the grain aphid, Schizaphis graminum (Rondani, 1852), which substantially reduces grain production, slows down root growth and impairs tillering. As a consequence of the attack, the application of insecticides that are poorly managed leads to a series of economic and environmental damages. The objective of this work was to study the combinations of application rates, tips and adjuvants on the chemical control of wheat aphid in wheat and the environmental impacts on the populations of its natural enemies. Imidacloprid insecticide applications were carried out in two seed multiplication fields of cultivar BRS 404. Two application rates (75 and 150 L.ha-1) were used with and without the addition of two adjuvants of different chemical characteristics combined with three types of hydraulic spray tips. For the laboratory studies of evaluation of the physicochemical properties of the grouts, through the evaluation of variance there was a significant interaction of the conductivity and surface tension properties with the adjuvants evaluated. In relation to the technologies used, the deposition of the applied syrup on the flag and ears leaves at the lower application rate (75 L ha-1) was statistically similar to the deposition at a higher application rate (150 L ha-1), regardless of the use of adjuvant. The treatments with high efficiency throughout the control period were those containing adjuvants in the two application rates tested (75 L ha-1 and 150 L ha-1) demonstrating that it is possible to reduce the volume of syrup in applications that have as objective the control of the aphid-cereals without loss of effectiveness in the treatment. The insecticide imidacloprid showed to be highly harmful to predators of Chrysoperla externa and Orius insidiosus, causing mortality in the first three days after application, regardless of the application technology used. / Dissertação (Mestrado)
5

Floto-filtração como pós-tratamento de efluente de reator anaeróbio tratando esgoto sanitário / Floto-filtration as post-treatment of an anaerobic reactor effluent

André Luiz de Oliveira 23 February 2007 (has links)
Este trabalho compreende o estudo do desempenho de sistema piloto de floto-filtração, aplicado ao pós-tratamento de efluente de reator anaeróbio, sob diferentes taxas de aplicação superficial, quantidade de ar fornecida ao processo e leitos filtrantes. O trabalho foi dividido em duas fases: ensaios preliminares (fase 1) e ensaios com o floto-filtro (fase 2), sem utilização de leito filtrante (etapa 1 da fase 2) e com utilização do leito filtrante (etapa 2 da fase 2). A fase 1, realizada com unidade de flotação por ar dissolvido em escala de bancada, apresentou resultados satisfatórios em termos de redução de turbidez, cor e Abs254nm para dosagens de cloreto férrico entre 40 a 80 mg/L na maior parte dos ensaios. Os dados desta fase serviram principalmente para a determinação e adoção dos melhores parâmetros operacionais a serem utilizados na fase seguinte. Na etapa 1 da fase 2, o sistema foi analisado sob a ótica da qualidade da água produzida em condições variáveis de dosagem de cloreto férrico, tempo e gradiente de floculação, taxa de recirculação e taxa de aplicação superficial. Para as amostras coletadas foram analisadas as variáveis turbidez, temperatura, condutividade, DQO, SST, pH, cor, Abs254nm, metais, OD, \'P-PO IND.4\'POT.3-\', NTK e \'N-NH IND.4\'POT.+\'. Foram obtidas eficiências globais de 88 a 97% de redução na turbidez (residual < 20 uT), 84 a 98% de SST (residual < 25 mg/L), 87 a 94% de \'DQO IND.B\' (residual < 60 mg/L), 78 a 92% de \'DQO IND.F\' (residual < 40 mg/L), 85 a 96% de \'P-PO IND.4\'POT.3-\' (residual < 2 mg/L) e menor que 30% para NTK e \'N-NH IND.4\'POT.-\'. Na etapa 2 da fase 2, além das análises supracitadas, foram analisadas as variáveis DBO, coliformes totais e fecais, sulfatos, dureza, alcalinidade, ácidos voláteis e turbidez ao longo do leito filtrante além da medida de perda de carga no decorrer da carreira de filtração. Foram monitorados a perda de carga ao longo do leito filtrante, carreira de filtração. Nesta fase, a instalação piloto de floto-filtração foi avaliada mediante a variação da taxa de aplicação superficial e do leito filtrante. Os resultados foram positivos com efluente final apresentando turbidez média abaixo de 2 uT e duração média da carreira filtração de 24 horas. Foram obtidas eficiências globais de 96 a 99% de redução na turbidez (residual < 7 uT), 96 a 99% de SST (residual < 6 mg/L) , 93 a 96% de \'DQO IND.B\' (residual < 40 mg/L), 89 a 97% de \'DQO IND.F\' (residual < 34 mg/L), 93 a 98% de \'P-PO IND.4\' POT.3-\' (residual < 0,3 mg/L), menor que 30% para NTK e \'N-NH IND.4\' POT.-\', 96 a 98% de cor (residual < 50 uC) e 80 a 82% de Abs254nm (residual < 0,198). Desta forma, em virtude dos bons resultados apresentados, pôde-se constatar que a floto-filtração é uma alternativa atraente no pós-tratamento de efluente de reator anaeróbio. / This works assesses the performance of a floto-filtration pilot system, applied to the post-treatment of an anaerobic reactor effluent, under different superficial application rates, amount of air supplied to the process and filter beds. The work was divided in two phases: preliminary essays (phase 1), essays with the floto-filter without using filter bed (step 1 of phase 2) and essays with the floto-filter using filter beds (step 2 of phase 2). Phase 1, carried out with bench scale dissolved air flotation unit, presented satisfactory results regarding turbidity removal, color and Abs254nm for ferric chloride dosages between 40 - 80 mg/L in most of the essays. The data acquired from this phase were mainly used to determine and adopt the best operational parameters to be employed in the following phase. In step 1 of phase 2, the system was analyzed concerning the quality of the water produced in favorable conditions for ferric chloride dosages, time and flocculation gradient, recirculation gradient and superficial application rate. The following variables were analyzed from the collected samples: turbidity, temperature, conductivity, COD, TSS, pH, color, Abs254nm, metais, OD, \'P-PO IND.4\'POT.3-\', NTK and \'N-NH IND.4\'POT.+\'. Global efficiencies of 88 to 97% for turbidity removal (residual < 20 uT), 84 to 98% for TSS (residual 25 mg/L), 87 to 94% for COD (residual < 60 mg/L), 78 to 92% for CODF (residual < 40 mg/L), 85 to 96% \'P-PO IND.4\'POT.3-\' (residual < 2 mg/L) and less than 30% for NTK and \'N-NH IND.4\'POT.+\' were obtained. In step 2 of phase 2, besides the aforementioned analyses, BOD, total and fecal coliforms, sulphates, hardness, alkalinity, volatile acids and turbidity throughout the filter in addition to the measure of headloss during the filter run. In this phase, the floto-filtration pilot plant was assessed varying the superficial application and filter bed rate. The results were positive with the final effluent presenting mean turbidity below 2 uT and mean filter run time of 24 hours. Global efficiencies of 96 to 99% for turbidity removal (residual < 7 uT), 96 to 99% for TSS (residual < 6 mg/L), 93 to 96% for \'COD IND.B\' (residual < 40 mg/L), 89 to 97% for \'COD IND.F\' (residual < 34 mg/L), 93 to 98% for \'P-PO IND.4\'POT.3-\' (residual < 0,3 mg/L), less than 30% for NTK and \'N-NH IND.4\'POT.-\', 96 to 98% for color (residual < 50 uC) and 80 to 82% for Abs254nm (resisual < 0,198). Thus, due to the good results that were presented, it can be said that floto-filtration is an attractive alternative for the post-treatment of an anaerobic reactor effluent.
6

Influência da velocidade cross-flow na câmara de flotação na eficiência de unidades de flotação por ar dissolvido tratando água para abastecimento / The influence of cross-flow velocity in the flotation chamber on efficiency of a dissolved air flotation unit treating drinking water

Cláudio Júnior Araújo 07 October 2010 (has links)
O reator de FAD deve propiciar condições adequadas para contato entre as micro-bolhas e os flocos formados no pré-tratamento e também condições para que o conjunto floco/bolha possa ser direcionado ao topo do reator, e assim ser removido. O projeto de pesquisa visou estudar condições hidrodinâmicas proporcionadas pela variação da Velocidade Cross-Flow (VCF) e assim verificar a influência na eficiência de uma estação piloto de flotação por ar dissolvido. A VCF é importante parâmetro para concepção de unidades de FAD e é função da vazão de entrada no tanque de flotação e da área entre o nível d\'água no tanque de flotação e o anteparo que separa a zona de contato da zona de separação. A velocidade cross-flow constitui um parâmetro de grande importância para projetos de unidades de flotação. Nesta região de transição entre a zona de contato e a zona de separação, ocorre a passagem do conjunto floco/bolha, e turbulência excessiva pode causar o rompimento do conjunto e assim comprometer a eficiência da flotação. Além disso, o padrão de escoamento observado na zona de separação dos flotadores, onde ocorre a separação dos aglomerados \"flocos + bolhas\", depende fortemente do valor médio da velocidade cross-flow, conforme comentado por Lundh et al. (2000 e 2002) e por Reali e Patrizzi (2007). Daí a necessidade de se investigar mais profundamente a influência da VCF na eficiência da clarificação por flotação. O projeto de pesquisa foi dividido em duas etapas. Para realização das etapas foi estudado um tipo de água preparada em laboratório, através da adição de substância húmica e caulinita, para obtenção de cor aparente e turbidez, respectivamente. A água estudada possui cor aparente e turbidez moderada (1 mg/L de substância húmica e 8,5 mg/L de caulinita) resultando em valores de turbidez por volta de 7 NTU e cor aparente por volta de 40 UH. A etapa 1 consistiu na determinação do par, pH de coagulação e dosagem de coagulante (sulfato de alumínio), gradiente médio de floculação e tempo médio de floculação adequado para a água de estudo. Para realização da etapa 1 foi utilizado equipamento de flotação de bancada de regime de batelada (Flotateste), que se encontra nas dependências do Laboratório de Tratamento Avançado e Reuso de Águas - LATAR/SHS/EESC/USP. Foram mantidos fixos os seguintes parâmetros: \'T IND.MR\', \'G IND.MR\', \'T IND.F\', \'G IND.F\', \'P IND.SAT\', \'T IND.REC\', \'V IND.FLOT\'. Conforme preconizado por Reali et al (2007), foi variada a dosagem de coagulante. Após determinado o melhor par pH e dosagem de coagulante foram realizados ensaios visando determinar o melhor \'G IND.F\' e \'T IND.F\' para a água em estudo. Para a água de estudo foram escolhidas duas condições de potencial Zeta, determinados na etapa 1 do projeto de pesquisa. A primeira condição o potencial Zeta permaneceria com valor próximo de 0 mV e na segunda condição o potencial Zeta seria positivo, por volta de +12 mV. A etapa 2 consistiu em variar a velocidade cross-flow, através da variação da altura do vertedor de saída da água flotada de uma unidade piloto de flotação, de forma a se obter diferentes valores de VCF (mantendo-se constantes os valores de tempo de contato e taxa de aplicação superficial na zona de contato), para dois valores de Taxas de Aplicação Superficial (TAS) (7,67 m/h e 15 m/h) na zona de separação e os dois valores de potencial Zeta (PZ), e com isto avaliar a sua influencia na eficiência de remoção de sólidos suspensos totais, cor e turbidez da instalação piloto retangular de FAD. / The reactor DAF should provide adequate conditions for contact between the micro-bubbles and the flakes formed in the pretreatment conditions and also for the aggregate flocs/bubble can be directed to the top of the reactor, and thus be removed. The research project aimed at studying hydrodynamic conditions provided by the variation of Cross-Flow Velocity (VCF) and thus checks the influence on the efficiency of a pilot plant of dissolved air flotation. The VCF is an important parameter to design units of DAF and is a function of input flow in the flotation tank and the area between the water level in the flotation tank and the bulkhead that separates the contact zone of the zone of separation. The cross-flow velocity is a parameter of great importance to projects of flotation units. In this region of the transition zone between the contact zone and the separation zone, occurs the passage of the aggregate flocs/bubble, and excessive turbulence can cause disruption of the aggregate and thereby harm the flotation efficiency. Moreover, the pattern of flow observed in the flotation separation zone, which occurs the separation of aggregates \"flakes + bubbles\", depends strongly on the average value of cross-flow velocity as described by Lundh et al. (2000 and 2002) and Reali and Patrizzi (2007). Hence the needs to investigate further the influence of VCF on the clarification efficiency by flotation. The research project was divided into two steps. To perform the steps has been studied a type of water prepared in the laboratory, through the addition of humic substances and kaolin, to obtain apparent color and turbidity, respectively. The study water has moderate turbidity and apparent color (1 mg/L of humic substance and 8.5 mg/L of kaolin) resulting in turbidity values around 7 NTU and color apparent by 40 HU. Step 1 consisted in the determination of the pair, coagulation pH and coagulant dosage (aluminum sulfate), flocculation gradient and time flocculation suitable for the study water. For the implementation of step 1 was used bench batch flotation system equipment (Flotatest), located on the Laboratory for Advanced Treatment and Reuse Water - LATAR / SHS / EESC / USP. Were kept fixed the following parameters: \'T IND.MR\', \'G IND.MR\', \'T IND.F\', \'G IND.F\', \'P IND.SAT\', \'T IND.REC\', \'V IND.FLOT\'. As predicted by Reali et al (2007), was varied the dosage of coagulant. After determined the best pair of coagulant dosage and pH coagulation the tests were performed to determine the best \'G IND.F\' and \'T IND.F\' for the study water. For the study water were chosen two conditions of Zeta potential values, determined in the step 1 of the research project, where the first condition the Zeta potential value kept near 0 mV and the second condition kept a positive value of Zeta potential, around +12 mV. The step 2 consisted of varying the cross-flow velocity, by varying the height of the outlet weir of the clarified water of the flotation pilot plant to obtain different values of VCF (keeping constant the values of time contact and application rate on the contact zone) for two values of superficial application rates (7.67 m/h and 15 m/h) in the zone of separation and the two values of Zeta potential (PZ) and then was availed the influence on removal efficiency of total suspended solids, colour and turbidity of the rectangular pilot plant of DAF.
7

Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable water

Meca, Karen Soraia 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
8

Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable water

Karen Soraia Meca 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.

Page generated in 0.1047 seconds