• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 385
  • 336
  • 86
  • 52
  • 37
  • 21
  • 18
  • 14
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • Tagged with
  • 1168
  • 506
  • 236
  • 225
  • 221
  • 181
  • 177
  • 157
  • 152
  • 118
  • 109
  • 101
  • 97
  • 94
  • 94
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Sistema adesivo universal: influência da técnica de condicionamento e da pressão pulpar com soro fetal bovino ou água deionizada na resistência de união à dentina humana

Gonçalves, Lucélia Lemes [UNESP] 15 December 2014 (has links) (PDF)
Made available in DSpace on 2015-09-17T15:24:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-12-15. Added 1 bitstream(s) on 2015-09-17T15:47:16Z : No. of bitstreams: 1 000844444.pdf: 2215824 bytes, checksum: b4f816ee13ee382fcf0bf5de0f4cbd09 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A simulação da pressão pulpar é importante para reprodução das condições in vivo nos testes de resistência adesiva. Esse estudo avaliou a influência da pressão pupar simulada, utilizando soro fetal bovino ou água deionizada, na resistência de união à dentina do sistema adesivo Single Bond Universal (3M ESPE; Brasil Ltda.), in vitro, aplicado sob diferentes formas de condicionamento dentinário, ácido total e autocondicionante, através do teste de microtração. Setenta e dois molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 3 grupos: Grupo controle - sem pressão pulpar (n = 24); Grupo pressão pulpar soro - pressão pulpar com soro fetal bovino (n = 24); Grupo pressão pulpar água - pressão pulpar com água deionizada (n = 24). Em seguida, os espécimes foram divididos em 2 subgrupos (n = 12): Subgrupo condicionamento ácido total - ácido fosfórico 37% + SB Universal; Subgrupo autocondicionante - SB Universal. O sistema adesivo foi aplicado de acordo com a técnica de condicionamento dentinário ácido total ou autocondicionante, sob a simulação da pressão pulpar com 0 ou 15 cm de soro fetal bovino ou água deionizada (durante todo o procedimento restaurador). Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada, os dentes foram seccionados para a obtenção de palitos com área adesiva de 1 mm2, e submetidos ao teste de microtração após 1 dia de armazenamento. A variação da resistência adesiva entre os grupos foi analisada pelos testes estatísticos ANOVA 2-fatores e Tukey (5% de significância). A maior média de resistência adesiva foi apresentada pelo grupo sem pressão pulpar simulada sob condicionamento dentinário.... / The simulation of pulpal pressure is important for reproduction of in vivo conditions in tests of bond strength. This study evaluated the influence of the etching technique and simulated pulpal pressure with fetal bovine serum or deionized water on bond strength to dentin of Universal Single Bond (3M ESPE;. Brazil Ltda) in vitro. Seventy-two healthy human molars were cut 1 mm below the cemento-enamel junction to separate the crown of radicular portion and cut parallel to the occlusal surface for exposure of 2 mm thickness of dentin. Samples were randomly divided into 3 groups: control group - no pulpal pressure (n = 24); pulpal pressure group serum - pulpal pressure with bovine fetal serum (n = 24); pulpal water pressure group - pulpal pressure with deionized water (n = 24). Then, the subjects were divided into 2 subgroups (n = 12): Subgroup total etch - phosphoric acid 37 % + SB Universal; Self-etch subgroup - SB Universal. The adhesive system was applied according to the technique total-etch or self-etch under pressure simulation with pulp 0 or 15 cm bovine fetal serum or deionized water (throughout the restorative procedure). The specimens were restored with composite resin Filtek Z350 XT (3 m ESPE). After 48 h in deionized water, teeth were sectioned for obtaining beans with 1 mm² adhesive area, and subjected to the test,after 1 day of storage. The variation of bond strength between the groups was analyzed by ANOVA 2-way (simulated pulpal pressure and etch technique) and Tukey (5 % of significance). The highest average bond strength was presented by the group without simulated pulpal pressure self-etch (37.25 ± 4.12) and the lowest average by group simulated pulpal pressure with deionized water and self-etch procedure (26.12 ± 6, 46). There was statistically significant difference for the average bond strength of all groups tested without pressure (36.15a), pulpal ...
112

Experimental and numerical analysis of damage in CFRP laminates under static and impact loading conditions

Tsigkourakos, George January 2013 (has links)
Engineering composites and especially long fibre carbon composites have been in high demand not only in aerospace and automotive applications, but also in high end everyday applications. In aerospace, carbon composites are used predominantly for secondary structures attached by joints or fasteners to various alloys or even different composites, and are exposed to service loads and repetitive impacting. Impact fatigue (IF) is not studied adequately for long cycles and relevant literature is investigating mainly drop weight tests and high speed projectile experiments. The main aim of this research was to investigate the behaviour long fibre CFRP'S exposed to repeated low-velocity, low energy impacts, and to observe the damage effects of this regime on the structural integrity of these materials. Two types of specimen configurations using CFRPS's were used and exposed to loading conditions relevant to the Izod impact fatigue test (IIFT), and the tensile impact fatigue test (TIFT), in order to determine the fatigue behaviour of the specimens for each of these load conditions. For the IIFT, the fatigue life was investigated using IM7/8552 unidirectional specimens and T700/LTM45 cross-ply specimens were utilised for the TIFT. The specimen thicknesses were altered in both cases and parametric studies were carried out, where it was seen that IF results in high level of scatter and the apparent decrease in life was seen at relatively modest levels of maximum force after relatively few cycles. In the case of the IIFT, a durability limit was not apparent which increases the complications when designing against IF. In the case of the TIFT the stiffness deterioration was reflected as an increase of the loading time, in the force vs time graph, over the total fatigue life span. Fatigue crack growth was investigated using fractography and X-ray micro-CT at the micro and macro level. It was seen, that IF had the potential to initiate cracks and to cause their propagation at low levels of loading. For the IIFT, a single crack was growing substantially in the fibre direction and across the sample width causing matrix cracking and probably breaking of some fibres, which acted as impact wave guides since matrix cracks were propagating initially along the length of the fibres. In the case of the TIFT multiple damage modes were presented (matrix cracks, axial splits and delaminations). Their sequence and progression was successfully v captured and contrasted against the number of impacts. Axial splits governed the damage scenario, with delaminations extending between them and the free edges. For the TIFT, IF was studied using the force-life (F-Nf) and energy-life (E-Nf) curves. The tests undertaken showed that when halving the thickness of the laminates the fatigue life presented a 10-fold decrease as well as higher scatter. Finite element modelling was undertaken to validate the experimental data of the TIFT test. Successful simulation of a single impact was carried out using a fully transient 3-D model of the actual experiment configuration which involved geometric non-linearities in addition to the multiple contact conditions. The analysis was undertaken using the Abaqus 6.11 explicit solver. Since the numerical single impact results (force vs time response) was in agreement with the experimental results, the crack modes, experimentally observed, were also incorporated in the model utilising the use of the cohesive zone elements (CZE).
113

Influência da dentina bovina e do dispositivo de microtração na resistência de união de sistemas adesivos /

Yamamoto, Lígia Tiaki. January 2014 (has links)
Orientador: Rubens Nisie Tango / Banca: Eduardo Bresciani / Banca: Mirela Sanae Shinohara / Resumo: Este trabalho teve como objetivos: simular em elementos finitos a distribuição de tensão nos dispositivos de microtração Geraldeli e Modificado durante o teste de microtração; avaliar a resistência de união entre a dentina bovina e a resina composta colada em duas direções: Esmalte-Polpa e Polpa-Esmalte, em dois dispositivos para microtração diferentes: Geraldeli e Modificado. Foi criado o modelo de elementos finitos com a geometria externa baseada em um modelo real no software CAD, e simulado as situações experimentais (geometria, carregamento e fixação) e exportado para o software de análise estrutural Ansys. Para o teste de microtração, foram confeccionados blocos de resina composta colados a dentina bovina com dois tipos de adesivos diferentes (convencional e autocondicionante), que foram testados nos dois dispositivos para microtração. Os valores de resistência de união foram tabulados e submetidos a ANOVA 3 fatores (Tipo de dispositivo X Direção da dentina X Tipo de adesivo) e Teste de Tukey (α = 0,05). As falhas de cada grupo foram classificadas em adesivas, mistas e coesivas com o auxílio de estereomicroscópio e MEV. A distribuição de tensão no dispositivo Geraldeli mostra concentração de tensão na região adesiva do palito e distribuída não-uniformemente (isolinhas oblíquas), com áreas de tração na diagonal da interface adesiva; e no dispositivo Modificado a tensão também está concentrada na região adesiva porém distribuída mais uniformemente (isolinhas paralelas), radial à área adesiva. Foram observadas diferenças significativas para a interação entre Dispositivo X Dentina X Adesivo (p = 0,001), Dispositivo X Dentina (p = 0,000), Dentina X Adesivo (p = 0,017). O adesivo e a dentina também tiveram influência nos resultados de microtração (p = 0,013 e 0,000, respectivamente). Para o dispositivo de Geraldeli, o adesivo convencional obteve melhor resistência de união que o... / Abstract: This project aimed to: simulate in finite element the stress distribution in Geraldeli and Modified's microtensile device during microtensile test; evaluate the bond strength between bovine dentin and composite resin bonded in two ways: enamel-pulp and pulp-enamel tubule directions, in two different devices for microtensile test: Geraldeli and Modified. The external geometry based on a real model was done in CAD software, experimental conditions were simulated (geometry, loading and fixation) and exported to structural analysis software Ansys. For microtensile test, bovine dentin blocks were bonded to composite resin with two different types of adhesives (conventional and self-etching), which were tested on both microtensile devices. The bond strength values were tabulated and subjected to ANOVA 3-WAY and Tukey's test statistical analysis (α = 0,05). Failures in each group were classified as adhesive, cohesive and mixed in stereomicroscope and SEM. The stress distribution in Geraldeli's device shows stress concentration in the adhesive region of the stick and distributed non-uniformly (oblique contours), with tension areas in the diagonal of the adhesive interface; Modified's device show stress concentration in the adhesive region too but more evenly distributed (parallel contours, radial to the adhesive area. Significant differences for the interaction between device device X dentine X adhesive (p = 0.001), device X dentine (p = 0.000), dentin X adhesive (p = 0.017) were observed. The adhesive and dentin were also influenced the results of microtensile test (p = 0.013 and 0.000, respectively). For Geraldeli device, conventional adhesive got better bond strength than the self-etching, in Pulp-Enamel; and Pulp-Enamel way got lower bond strength for the selfetching adhesives. For modified device, there was no statistical difference among the groups / Mestre
114

Sistema adesivo universal: influência da técnica de condicionamento e da pressão pulpar com soro fetal bovino ou água deionizada na resistência de união à dentina humana /

Gonçalves, Lucélia Lemes. January 2014 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Taciana Marco Ferraz Caneppele / Co-orientador: Huéder Paulo Moisés de Oliveira / Banca: Eduardo Bresciani / Banca: Ana Cecília Côrrea Aranha / Resumo: A simulação da pressão pulpar é importante para reprodução das condições in vivo nos testes de resistência adesiva. Esse estudo avaliou a influência da pressão pupar simulada, utilizando soro fetal bovino ou água deionizada, na resistência de união à dentina do sistema adesivo Single Bond Universal (3M ESPE; Brasil Ltda.), in vitro, aplicado sob diferentes formas de condicionamento dentinário, ácido total e autocondicionante, através do teste de microtração. Setenta e dois molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 3 grupos: Grupo controle - sem pressão pulpar (n = 24); Grupo pressão pulpar soro - pressão pulpar com soro fetal bovino (n = 24); Grupo pressão pulpar água - pressão pulpar com água deionizada (n = 24). Em seguida, os espécimes foram divididos em 2 subgrupos (n = 12): Subgrupo condicionamento ácido total - ácido fosfórico 37% + SB Universal; Subgrupo autocondicionante - SB Universal. O sistema adesivo foi aplicado de acordo com a técnica de condicionamento dentinário ácido total ou autocondicionante, sob a simulação da pressão pulpar com 0 ou 15 cm de soro fetal bovino ou água deionizada (durante todo o procedimento restaurador). Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada, os dentes foram seccionados para a obtenção de palitos com área adesiva de 1 mm2, e submetidos ao teste de microtração após 1 dia de armazenamento. A variação da resistência adesiva entre os grupos foi analisada pelos testes estatísticos ANOVA 2-fatores e Tukey (5% de significância). A maior média de resistência adesiva foi apresentada pelo grupo sem pressão pulpar simulada sob condicionamento dentinário.... / Abstract: The simulation of pulpal pressure is important for reproduction of in vivo conditions in tests of bond strength. This study evaluated the influence of the etching technique and simulated pulpal pressure with fetal bovine serum or deionized water on bond strength to dentin of Universal Single Bond (3M ESPE;. Brazil Ltda) in vitro. Seventy-two healthy human molars were cut 1 mm below the cemento-enamel junction to separate the crown of radicular portion and cut parallel to the occlusal surface for exposure of 2 mm thickness of dentin. Samples were randomly divided into 3 groups: control group - no pulpal pressure (n = 24); pulpal pressure group serum - pulpal pressure with bovine fetal serum (n = 24); pulpal water pressure group - pulpal pressure with deionized water (n = 24). Then, the subjects were divided into 2 subgroups (n = 12): Subgroup total etch - phosphoric acid 37 % + SB Universal; Self-etch subgroup - SB Universal. The adhesive system was applied according to the technique total-etch or self-etch under pressure simulation with pulp 0 or 15 cm bovine fetal serum or deionized water (throughout the restorative procedure). The specimens were restored with composite resin Filtek Z350 XT (3 m ESPE). After 48 h in deionized water, teeth were sectioned for obtaining beans with 1 mm² adhesive area, and subjected to the test,after 1 day of storage. The variation of bond strength between the groups was analyzed by ANOVA 2-way (simulated pulpal pressure and etch technique) and Tukey (5 % of significance). The highest average bond strength was presented by the group without simulated pulpal pressure self-etch (37.25 ± 4.12) and the lowest average by group simulated pulpal pressure with deionized water and self-etch procedure (26.12 ± 6, 46). There was statistically significant difference for the average bond strength of all groups tested without pressure (36.15a), pulpal ... / Mestre
115

Resistência adesiva de um sistema auto-condicionante e um convencional simplificado, aplicados à dentina tratada com diferentes condicionadores

Jacques, Paula [UNESP] 14 May 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-05-14Bitstream added on 2014-06-13T20:36:15Z : No. of bitstreams: 1 jacques_p_me_arafo.pdf: 6578711 bytes, checksum: 7ce3c1075cc06b0164a5b42ddcb9c7d0 (MD5) / A resistência adesiva de um sistema auto-condicionante e um convencional simplificado, Clearfil SE Bond e Single Bond, respectivamente, quando aplicados à dentina superficial tratada com diferentes agentes condicionadores, foi avaliada por meio de ensaios mecânicos de microtração. Superfícies planas de dentina, obtidas removendo-se a superfície oclusal de 30 terceiros molares humanos foram polidas com lixa de granulação 600 antes da aplicação de diferentes agentes condicionadores, SE Primer, ácido fosfórico ou EDTA. O primer acidificado SE Primer foi aplicado sobre a superfície por 20 segundos, seguido de suave secagem com jatos de ar. O ácido fosfórico a 37% foi aplicado por 15 segundos, seguido de lavagem e remoção do excesso de água com papel absorvente e a solução de EDTA 0,5M pH7,2 foi aplicada por 30 segundos, também seguida de lavagem e secagem. Com exceção das superfícies que receberam a aplicação do primer acidificado, as demais foram mantidas úmidas para a posterior aplicação dos sistemas adesivos avaliados. Sobre a superfície coberta pelo sistema adesivo foi construída uma coroa em resina composta Z250 e os dentes foram mantidos em água a 37% por 24h. Após 500 ciclos térmicos em temperaturas de 5o e 55oC, cortes paralelos no sentido mesio-distal e cortes perpendiculares aos primeiros, no sentido vestibulo-lingual, permitiram a obtenção de amostras com área de secção transversal quadrangular de 1,0mm2 em número mínimo de 10 para cada dente. Cada amostra foi colada a um dispositivo especialmente desenvolvido, e este foi acoplado à uma máquina universal de testes operada à velocidade de 0,5mm/min. O lado correspondente à dentina de aproximadamente 50% das superfícies fraturadas após o ensaio mecânico foi analizado em MEV. Os resultados mostraram que o maior valor médio de resistência adesiva foi observado para a associação SE Primer... . / Microtensile bond strength of a self-etching primer and a conventional one-bottle system, Clearfi SE Bond and Single Bond, respectively, bonded to superficial dentin treated with different conditioners was investigated. Flat dentin surfaces obtained by removing the occlusal enamel with a diamond saw were ground with 600-grit SiCs under wet conditions to create the smear layer before the conditioners application. Three different dentin conditioning was performed, SE Primer, phosphoric acid and EDTA. The SE Primer was applied on dentin for 20 seconds followed by slight air-drying. Phosphoric acid (37%) was applied for 15 seconds followed by rinsing. EDTA 0.5M pH7.2 was applied for 30 seconds, also followed by water rinsing. Except for the surfaces that received the SE Primer conditioner, the surfaces were left moist by blot-drying the excess water. The adhesive systems were applied and a 5mm high composite resin (Z250) was built up covering the whole surface. After 24h of storage in water at 37oC the teeth were thermocycled for 500 cycles at preset temperatures of 5o and 55oC. The teeth were sectioned with a diamond saw, perpendicular to the adhesive interface to produce beams with 1.0mm2 of adhesive area. These specimens were then attached to a testing apparatus and a tensile load was applied by a universal machine at a crosshead speed of 0.5mm/min. After the micro-tensile bond test, the dentin side of 50% of the fractured surfaces was examined under a scanning electron microscope. The highest tensile bond strength mean was found for the association of SE Primer and Single Bond, 58.51MPa, followed by the association Clearfil SE Bond and EDTA, 47.81MPa. The remaining associations showed mean tensile bond strength statistically similar, except for the association Single Bond and EDTA, which showed the lowest... (Complete abstract, click electronic address below).
116

Avaliação da resistência de união em dentina de um adesivo de frasco único quando utilizado diferentes fontes de ativação

Kreidler, Martín Antúnez de Mayolo [UNESP] 14 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-14Bitstream added on 2014-06-13T20:51:31Z : No. of bitstreams: 1 kreidler_mam_me_arafo.pdf: 1061515 bytes, checksum: 8631de69ed2363b4ba75419b58ee0e3b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O propósito deste estudo foi avaliar através do teste de microtração e da análise do padrão de fratura, o efeito da luz halógena e LED, na ativação de um adesivo de frasco único. Superfícies dentinárias planas foram criadas em 16 dentes terceiros molares hígidos. Os dentes foram aleatoriamente divididos em 4 grupos: Grupo G1 - Aparelho de luz halógena - KM-200R®; Grupo G2 - Aparelho LED - Ultraled®; Grupo G3 - Aparelho LED - UltraLume®LED5 e Grupo G4 - Aparelho LED - Biolux Single V®. O procedimento restaurador foi realizado utilizando o adesivo Single Bond® e a resina composta InTen-S®. Após as restaurações, os dentes foram armazenados em água destilada e estufa a 37ºC por 24h. A seguir, os mesmos foram cortados, resultando em espécimes com área de aproximadamente 1 mm2, que foram selecionados e submetidos ao teste de microtração para posterior observação do padrão de fratura no microscópio digital. Os resultados, submetidos a análise estatística mostram que o grupo G2 teve média de resistência de união significativamente menor que os demais grupos, que foram semelhantes entre si. Quanto ao tipo de fratura, houve diferença significativa entre os grupos G1 e G2 e entre os grupos G2 e G4. Entre os outros grupos não houve evidência de diferenças significativas. As falhas de união foram predominantemente do tipo adesivas. Conclui-se que os aparelhos LEDs de segunda e terceira geração utilizados nesta pesquisa podem ser utilizados como uma alternativa viável à luz halógena. / The purpose of this study was to evaluate the effect of halogen light and LED on dentin tensile bond strength and fracture mode analysis. Flat dentin surfaces were created on 16 intact human third molars. The teeth were randomly divided in 4 groups: Group G1 - halogen - KM -200R®; Group G2 - LED - Ultraled®; Group G3 - LED - UltraLume LED5® and Group G4 - LED - Biolux Single V®. The restoration procedure used Single Bond® adhesive and InTen-S® composite resin. The teeth were placed in distilled water and stored at 37ºC for 24 hours. Then, they were cut on serial sections to obtain 1 mm2 area. The samples were submitted to micro tensile test and after words, the fractures were analysed with a digital microscope. The statistical analysis showed that all in all groups, except Group G2, which had a significant smaller tensile bond strength ratio. The fracture mode analysis showed that there were significant difference when comparing groups G1 / G2, and G2 / G4. There is no evidence of relevant differences among the other groups. Adhesive fracture was the most common fracture mode. As a conclusion, second and third LED generation used in this research could be use as an alternative to the conventional halogen lamp. Keyword: Dentin-bonding agents; tensile strength.
117

Avaliação in vitro da resistência de união do cerômero ao sistema de cimentação adesiva, através do teste de micro-tração. Efeito de diferentes tratamentos de superfície

Faria, Ricardo Pinheiro de [UNESP] 26 November 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-11-26Bitstream added on 2014-06-13T20:12:02Z : No. of bitstreams: 1 faria_rp_me_arafo.pdf: 2571722 bytes, checksum: 03eaaed6baf6d35de160ebd73d353c6a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A proposta deste estudo foi avaliar in vitro a resistência de união do Cerômero Artglass (Heraeus/Kulzer) ao cimento resiniso RelyX (3M), através do teste de Micro-Tração. Os seguintes tratamentos de superfície foram investigados: microjateamento com óxido de alumínio (AO), Artglass Liquid (AL), Silano (S), ácido fluorídrico (HF) e ácido fosfórico (AF). Cinco espécimes cada qual consistindo de um par de cilindro (10x10 mm) foram confeccionados. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação sequencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: grupo 1 (AO/AGL), grupo 2(AO/AF), grupo 3 (AO/AF/S), grupo 4 (AO/HF) e grupo 5 (AO/HF/S). Os espécimes aos pares foram cimentados com um sistema adesivo dual e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 horas a 37ºC e, posteriormente, termociclados. Com auxílio de um disco de diamente perpendicular a superfície de união, palitos com 1 mm2 de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS800). Resultados foram: grupo 1(29,39+-5,13), grupo 2 (27,49 +- 5,32), grupo 3(29,49 +- 4,94), grupo 4(24,41 +- 2,67), e grupo 5 (22,19 +- 2,33). ANOVA e o Teste de Tukey foram aplicados com p<0,05. Não houve diferenças estatisticamente significante entre os grupo 1,2 e 3; 4 e 5; e 2 e 4. As forças de união foram significantemente maiores nos grupos 1 e 3 do que nos grupos 4 e 5; e no grupo 2 do que o grupo 5. Conclusões: Microjateamento com óxido de alumínio e Artglass Liquid foi um pré-tratamento de superfície efetivo; a sinalização pode melhorar a força de união promovida pelo microjateamento e condicionamento... . / The purpose of this study was to investigate the effect of surface treatments on microtensile interfacial bond strength of a composite Artglass (Kulzer) to resin cement RelyX (3M). Methods of surfaces roughening or preparation included microetching with aluminum oxide (AO), Artglass Liquid (AGL), Silane (S), hydrofluoric acid (HF), and fosforic acid (AF). Five specimens, each consisting of a pair of cylinders (10x10 mm) were fabricated. The bonding surfaces were finished with 600-grit silicon carbide paper. Specimen pairs were randomly assigned to one of five surface treatment groups: group 1 (AO/AGL), group 2 (AO/AF), group 3 (AO/AF/S), group 4 (AO/HF), and group 5 (AO/HF/S). Specimen pairs were cemented with a dual resin bonding and a dual cure resin cement, in accordance with the manufacturer's instructions. Specimens were light-cured, then thermocycled 500 times at between 5º C and 55º C. Using a diamond disk perpendicular to the bonding interface, sticks with 1.0 mm2 cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. Results: Means (n=20) and standard deviations of bond strengths (MPa) were: group 1 (29.39 +- 5.13), group 2(27.49 +- 5.32), group 3(29.49 +- 4.94), group 4 (24.41 +- 2.67), and group 5 (22.19 +- 2.33). Data were analyzed with ANOVA and Tukey Test at p<0.05. There were no significant statistical differences among the groups 1,2, and group 3; groups 4 and 5; and groups 2 and 4. Microtensile bond strengths were significantly higher in groups 1 and 3 than in groups 4 and 5; and in group 2 than in group 5. Conclusions: AO and AGL was an effective surface pretreatment; silanation may improve the bond provided by AO and etching with AF; and etching with HF is not recommended, as it decreases bond strength.
118

Efeito da radiacao gama no policarbonato nacional Durolon FN2200

TERENCE, MAURO C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:50Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:11Z (GMT). No. of bitstreams: 1 02951.pdf: 3722798 bytes, checksum: 4c42b3ba1eb1c51f8f47bb210f5763f4 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
119

Avaliação da resistência adesiva e características da zircônia após diferentes tratamentos de superfície / Bond strength and surface characteristics evaluation of zirconia after different treatments

Fernandes Júnior, Virgílio Vilas Boas [UNESP] 01 September 2017 (has links)
Submitted by Virgílio Vilas Bôas Fernandes Júnior (virgiliovilas@hotmail.com) on 2017-10-25T17:19:32Z No. of bitstreams: 1 Tese FInal .pdf: 39214788 bytes, checksum: 9123d03a17e8efd22b18caf0276a31db (MD5) / Rejected by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br), reason: Solicitado pelo autor. on 2017-10-25T18:25:54Z (GMT) / Submitted by Virgílio Vilas Bôas Fernandes Júnior (virgiliovilas@hotmail.com) on 2017-10-25T19:32:12Z No. of bitstreams: 1 Tese Final pdf 3.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-10-30T17:58:25Z (GMT) No. of bitstreams: 1 fernandesjunior_vvb_dr_sjc.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) / Made available in DSpace on 2017-10-30T17:58:25Z (GMT). No. of bitstreams: 1 fernandesjunior_vvb_dr_sjc.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) Previous issue date: 2017-09-01 / O objetivo desse estudo in vitro foi avaliar a resistência adesiva, rugosidade superficial, ângulo de contato e o espectro infravermelho da zircônia, após diferentes tratamentos de superfície. Para isso, blocos (n=9) de zircônia Y-TZP (e.max ZirCad - Ivoclar, Schann, Liechtenstein) foram seccionados em 39 fatias (12 x 11x 3 mm) divididas em grupos de acordo com cada teste. Para resistência adesiva, 20 fatias foram divididos em: 2 grupos controle; JAT, jateamento com óxido de alumínio e sílica + primer (Monobond Plus - Ivoclar, Schann, Liechtenstein); HFP, condicionamento com ácido fluorídrico 10% + primer, e 3 experimentais: PL, plasma (Plasma Não Térmico de Superfície - modelo SAP); PLP, plasma + primer; HFPLP, ácido fluorídrico + plasma + primer. Cada fatia de zircônia foi cimentada (Multilink N - Ivoclair, Schann, Liechtenstein) a um bloco pré-polimerizado de resina composta. Após a cimentação os espécimes foram seccionados, e 48 palitos com área adesiva de 1 mm2 foram obtidos em cada grupo para o ensaio de microtração (μTBS). Quatro outras fatias foram submetidas à análise de rugosidade superficial e 12 fatias submetidas à análise do ângulo de contato, após os seguintes tratamentos de superfície: sem tratamento (AV), aplicação de ácido fluorídrico a 10% (AHF), aplicação de plasma (AP) e jateamento (AJ), sendo que para o ângulo de contato foram feitas medições imediatamente após o tratamento, após 12 e 24 horas. Os resultados foram submetidos à análise estatística Anova e teste de Tukey a 5% (p< 0,05). Os espectros das ligações químicas da superfície da zircônia foram determinados em 3 outras amostras após as seguintes condições: sem tratamento (AV), jateamento (JAT) e aplicação de ácido fluorídrico 10% seguido da aplicação do plasma (AHFP). Em termos de adesão, não houve diferença estatística significante entre os grupos JAT e HFPLP, porém esses 2 foram estatisticamente superiores ao grupos HFP, PL e PLP. O jateamento demonstrou aumentar significantemente a rugosidade superficial em relação aos demais grupos. O plasma demonstrou diminuir o ângulo de contato da superfície da zircônia imediatamente e ao longo de 48 horas. / The purpose of this in vito study was to evaluate zirconia bond strength, surface roughness, contact angle and to mesure infrared spectrum after different surface treatments. Y-TZP zirconium (e.max ZirCAD - Ivoclair, Schann, Liechtenstein) blocks (n=9) were sliced into 36 discs (12 x 11 x 3 mm) and divided (n=4) into surface treatment groups as following: two control groups: JAT, airborneparticle abrasion and HFP, 10% hydrofluoric acid etching + primer (Monobond Plus - Ivoclair, Schann, Liechtenstein)application ,and three experimental groups: PL, non-thermal plasma (Surface Non-Thermal Plasma SAP model) application; PLP non-thermal plasma + primer application, and HFPLP, 10% hydrofluoric acid etching + non-thermal plasma + primer application. Each zirconia disk was cemented (Multilink N - Ivoclair, Schann, Liechtenstein) to a pre-polymerized resin block (Filtek Z350 - 3M, St Paul, MN, USA). After cementation the specimens were sectioned and 48 sticks with adhesive area of 1 mm2 obtained from each group for micro-tensile testing (μTBS). Four discs were submitted to surface roughness analysis and 12 discs to contact angle analysis, after the following surface treatments: no treatment (AV), 10% hydrofluoric acid etching (AHF), non-thermal plasma application (AP); and airborne- particle abrasion (AJ). The results were submitted to ANOVA and Tukey's test (p < 0.05). Zirconia surface chemical bonds spectrum was determined in infrared spectroscopy for three specimens after the conditions: no treatment; airborne- particle abrasion and hydrofluoric acid etching + non-thermal plasma application. The results showed no statistically significant differences between the groups JAT and HFPLP, but these two groups were statistically superior to HFP, PL and PLP. Airborne- particle abrasion resulted in a significant increase of surface roughness compared to the other groups. Non-thermal plasma was shown to decrease the contact angle of the surface, within 48 hours.
120

Efeito da excitação ultrasônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro, após diferentes períodos de armazenamento /

Azevedo, Elcilaine Rizzato. January 2008 (has links)
Orientador: Angela Cristina Cilense Zuanon / Banca: Renata Cristiane da Silva / Banca: Josimeri Hebling da Costa / Resumo: Este estudo investigou o efeito da excitação ultra-sônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro (CIV), após 24 horas ou 30 dias de armazenamento em água destilada à 37ºC, por meio do teste de microtração. Os materiais utilizados foram o CIV de alta viscosidade Fuji IX GP, Ketac Molar e o modificado por resina, Vitremer. Foram confeccionados 12 corpos de prova para cada material, dos quais 6 formaram o grupo controle e 6 receberam tratamento com US, por 30 segundos. Para o experimento de resistência de união à dentina, trinta e seis terceiros molares foram divididos aleatoriamente entre os grupos experimentais já descritos. Em ambos os experimentos, após o período de armazenamento, os corpos de prova foram seccionados em espécimes com área adesiva média de 0,91mm2 (± 0,1) e 0,93 mm2 (± 0,09), respectivamente para o experimento de resistência à tração e de união. Os dados foram analisados pela análise de variância com a correção de Welch (p<0,001) e teste de Tamhane (α = 0,05). O cimento Fuji IX (24 horas) apresentou aumento significativo na resistência máxima à tração e o Ketac Molar (24 horas) na resistência de união à dentina, após a aplicação do US. Os grupos controle destes materiais também apresentaram aumento da resistência após 30 dias de armazenamento. Em todos os outros grupos experimentais não houve alteração significativa após a aplicação de US ou após diferentes períodos de armazenamento. A aplicação do ultra-som aumentou a resistência máxima à tração e de união à dentina, após 24 horas de armazenamento, quando se utilizou respectivamente, os cimentos Fuji IX e Ketac Molar. / Abstract: This study investigated the GICs ultimate tensile strength and bond to dentine after ultrasonic excitation and after periods of the 24 hours and 30 days storage in distilled water at 37ºC, using microtensile test. Two high viscosity GICs, Fuji IX GP and Molar Ketac, and the resin modified GIC Vitremer were used. Twelve specimens for each material were prepared, 6 formed the control group and 6 received treatment with US, por 30 seconds. For the ultimate tensile strength experiment, a cross-sectional area of 0.91mm2 (± 0.1) in the specimens were obtained. For the tensile bond strength to dentine test, 36 third molar were selected and randomly divided into groups, with a cross-sectional area of 0.93 mm2 (± 0.09). All specimens were tested in a microtensile test machine. The data were evaluated by analysis of variance and corrected by Welch (p<0.001) and Tamhane tests (α = 0.05). Fuji IX (24 hours) had significant increase in the ultimate tensile strength and Ketac Molar (24 hours) had significant increase in the tensile strength of union to dentine, after the application of the US. The control groups of the Fuji IX and Ketac Molar had increase in the tensile strength after 30 days of storage. All the other groups, did not show significant difference neither when US application was used nor between different storage times. The ultrasound application increased the ultimate tensile strength and bond to the dentine, after 24 hours of storage, when if it used respectively, the Ketac Molar and Fuji IX cements. / Mestre

Page generated in 0.0797 seconds